Sealed Ultra Subminiature Basic Switch
D2GW
The industry's smallest class *
(8.3 x 6.5 x 5.3 mm)
with a volume ratio that is 62% of
conventional models (D2AW)
• A fixed slit saves space on customer units and contributes
to a slim form
• A sliding structure delivers quiet operation
• Micro-load support thanks to high contact reliability
• Versatile actuator variation enables support for various
operating bodies (shapes, materials, operations)
• A bilaterally symmetrical shape contributes to simpler designs
• Press-fit terminals enable solder-less contact
* Based on Omron investigation in April 2021
RoHS Compliant
Model Number Legend
Some model number elements cannot be used in conjunction.
If you have any desired model with a specification not in this model number legend, contact your OMRON sales representative. We will
consider if a requested model can be manufactured by modifying existing models.
D2GW- @ @ @ @ @ - @
1
2
3
4
5
1. Mounting Structure
6
4. Contact Form
A: Side slot (Only terminal type)
2: SPST-NC
SC: M3-screw mounting models
3: SPST-NO
(Only lead wires type)
2. Actuator
0: Pin plunger
1: Straight hinge lever
3. Lever Mounting Position
5. Terminals
F: Press-fit terminals
D: Straight PCB terminals
H: Solder terminals
M: Lead wires
6. Option Code
None: Pin plunger or PCB terminals or Solder terminals
L:
Left side (Only Press-fit terminals/leaf lever type) *1
R:
Right side (Only Press-fit terminals/leaf lever type)
*1. The specifications for the lead wire type hinge lever are shown on the left only.
1
D2GW
List of Models
Model
Actuator
Terminals
PCB terminals
(straight)
Pin plunger
Press-fit terminals
Solder terminals
Molded lead wires
PCB terminals
(straight)
Contact Form
Lever Mounting
Position
SPST-NC
---
D2GW-A02D
---
---
D2GW-A03D
---
SPST-NC
---
D2GW-A02F
---
SPST-NO
---
D2GW-A03F
---
SPST-NC
---
D2GW-A02H
---
SPST-NO
---
D2GW-A03H
---
SPST-NC
---
---
D2GW-SC02M
SPST-NO
---
---
D2GW-SC03M
SPST-NC
---
D2GW-A12D
---
SPST-NO
---
D2GW-A13D
---
Left side
D2GW-A1L2F
---
Press-fit terminals
SPST-NO
Solder terminals
Molded lead wires
M3-screw
mounting models
SPST-NO
SPST-NC
Straight
hinge lever
Side slot
Right side
D2GW-A1R2F
Left side
D2GW-A1L3F
Right side
D2GW-A1R3F
---
SPST-NC
---
D2GW-A12H
SPST-NO
---
D2GW-A13H
---
SPST-NC
Left side
---
D2GW-SC1L2M
SPST-NO
Left side
---
D2GW-SC1L3M
---
If you have any desired model with a specification not in the above list, contact your OMRON sales representative. We will consider if a
requested model can be manufactured by modifying existing models.
2
D2GW
Contact Specifications
Contact
Slide
Specification
Material
Minimum applicable load ( see note )
Silver Plated
5 VDC 1 mA
Note: For more information on the minimum applicable load, refer to Using Micro Loads.
Ratings
Rating voltage
Resistive load
13.5 VDC
10 mA
Note: The rating values apply under the following test conditions.
1. Ambient temperature: 20 ± 2°C
2. Ambient humidity: 65 ± 5%
3. Operating frequency: 30 operations/min
Characteristics
Items
30 mm to 500 mm/s (pin plunger models)
Operating speed
Operating frequency
Mechanical
30 operations/min max.
Electrical
30 operations/min max.
Terminals
500 mΩ max.
Molded lead wires models
700 mΩ max.
Between same polarity
500 VAC 50/60 Hz 1min
Between current carrying metal
parts and ground
1,500 VAC 50/60 Hz 1min
Between each terminal and
non-current carrying metal part
1,500 VAC 50/60 Hz 1min
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Destruction
1,000 m/s2 Max.
Malfunction *1
300 m/s2 Max.
Mechanical
200,000 operations Min. (at 30 ops./min.)
Electrical
200,000 operations Min. (at 30 ops./min.)
100 MΩ min. (at 500 VDC)
Insulation resistance
Contact resistance
(initial value)
Dielectric strength
Vibration resistance *1
Shock resistance
Durability *2
Degree of protection
IEC IP67
Ambient operating temperature
-40 to +85°C (at 60% RH Max.) (with no icing or condensation)
Ambient operation humidity
95%RH max. (for +5 to +35°C)
Heart resistance
85°C 500 hours
Cold resistance
-40°C 500 hours
Humidity resistance
70°C 95% RH 500 hours
Temperature cycle resistance
-40°C (12 hours ⇔ 55°C (12 hours) 5 cycles
Weight
Approx. 0.5g (for pin plunger models with terminals)
Note: The data given above are initial values.
*1. For the pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For the lever models,
they apply at the total travel position. Close or open circuit of the contact is 1ms max.
*2. For testing conditions, consult your OMRON sales representative.
3
D2GW
Mounting Structure and Reference Positions for Operating Characteristics (Unit: mm)
● Side slot
D2GW-A
SR1.5
4
1±0.06
5.1
5.3
6.9±0.06
8.3±0.1
● M3-screw Mounting Models
D2GW-SC@
13.9
0
1.5 -0.1
8.3±0.1
SR1.5
3.3±0.05 dia.
3
6
3.1+0.1
0
3
0
-0.1 dia.
12
9.5
4
6
0
1.5 -0.1
D2GW
Terminals (Unit: mm)
● PCB terminals
SPST-NO
SPST-NC
Color: Blue
Color: Red
2-1
+0.1
0
dia. holes
5.5
5.5
3.81±0.1
2-0.6
2-0.6
0.4
3.81±0.1
● Solder terminals
SPST-NO
0.4
3.81±0.1
SPST-NC
Color: Red
Color: Blue
(2.5)
(2.5)
2-1.8
2-1.8
5.5
5.5
0.4
2-1.2
0.4
2-1.2
2-2
2-2
4.08
4.08
● Press-fit terminals
SPST-NO
Insertion side unit
mounting dimensions
(for reference only)
SPST-NC
Color: Red
Color: Blue
(8.4)
+0.07
7 -0.03
0.9
4.74
6.6
4.74
6.8±0.15
6.8±0.15
4.3
4.3
2-2.8
0.4
2-2.8
0.4
2.4
2-0.31±0.05
2-0.31±0.05
3.7±0.1
0.9
1.7
0.9
1.7
0.6
3.7±0.15
● Molded Lead Wires
SPST-NO
3.7±0.15
2.75
SPST-NC
Color: Red
Color: Blue
COM AVSS 0.3 (Black)
COM AVSS 0.3 (Black)
NC AVSS 0.3 (Red)
NO AVSS 0.3 (Blue)
300±10
300±10
(5)
(5)
5
D2GW
Dimensions (Unit: mm) / Operating Characteristics
CAD Data
Please visit our website, which is noted on the last page.
The following illustrations and drawings are for solder terminal models. PCB terminal models are omitted from the drawings. Refer to Terminals for these terminals.
When ordering, replace @ with the code for the rating that you need. For the combination of models, refer to List of Models.
● Pin plunger
D2GW-@0@@@
A
FP
OP
SR1.5
Operating
characteristics
Operating Force
Releasing Force
TTP
Type
OF
RF
Max.
Min.
Overtravel
OT
Movement Differential MD Max.
4
Free Position
FP Max.
Operating Position OP
Total Travel Position TTP
Side slot
M3-screw
mounting
models
1.2 N {122 gf}
0.1 N {10 gf}
1.7 mm (reference value)
0.25 mm
8.7 mm
8.0 ±0.3 mm
6.3 mm
7.7 mm
7.0 ±0.35 mm
5.3 mm
CAD Data
●Straight hinge lever
D2GW-@1@@@
A
t=0.2 Stainless-steel lever
(10.5)
3.4
3.2
1.15
Operating
characteristics
Operating Force
Releasing Force
Type
OF
RF
Max.
Min.
Overtravel
OT
Movement Differential MD Max.
FP
OP
(4.1)
TTP
4
Free Position
FP Max.
Operating Position OP
Total Travel Position TTP
Side slot
M3-screw
mounting
models
0.85 N {87 gf}
0.02 N {2 gf}
4.45 mm (reference value)
1.4 mm
11.05 mm
9.05 ±0.75 mm
4.6 mm
10.05 mm
8.05 ±0.75 mm
3.6 mm
CAD Data
Note: 1. Unless otherwise specified, a tolerance of ±0.2 mm applies to all dimensions.
2. The operating characteristics are for operation in the A direction ( ).
6
D2GW
Precautions
Please refer to "Safety Precautions for All Detection Switches" for correct use.
Cautions
●Degree of Protection
• Do not use this product underwater.
Although molded lead wire models satisfy the test conditions
for the standard given below, this test is to check the ingress of
water into the switch enclosure after submerging the Switch in
water for a given time. Satisfying this test condition does not
mean that the Switch can be used underwater.
JIS C0920:
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
IEC 60529:
Degrees of protection provided by enclosures (IP Code)
Degree of protection: IP67
(check water intrusion after immersion
for 30 min. submerged 1m underwater)
• Do not operate the Switch when it is exposed to water spray,
or when water drops adhere to the Switch surface, or during
sudden temperature changes, otherwise water may intrude
into the interior of the Switch due to a suction effect.
• Prevent the Switch from coming into contact with oil and
chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
• Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease. Otherwise faulty contact may result
due to the generation of silicon oxide.
Correct Use
●Mounting
• Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection.
Failure to do so may result in electric shock or burning.
• For M3-screw mounting models, use M3 mounting screws with
plane washers or spring washers to securely mount the Switch.
Tighten the screws to a torque of 0.27 to 0.29 N·m {27.5 to
29.5 gf}. Exceeding the specified torque may result in
deterioration of the sealing or damage.
• For models with posts, secure the posts by pressing into an
attached device. Provide guides on the opposite ends of the
posts to ensure that they do not fall out or rattle.
• When mounting a Press-fit terminals, press in A (body) and B
(terminal) in the drawing below at the same time.
If A (body) only is pressed in, the Press-fit terminals will be
deformed and will not be properly inserted.
Also, ensure that the Press-fit terminals is facing down when it
is inserted.
Avoid connecting soldered or laser-welded terminals.
Avoid mounting in conditions exposed to corrosive gases, high
temperature and humidity, and dust.
Insertion tool
Insertion tool
B
A
2.45
●Soldering
When soldering the lead wire to the terminal, first insert the
lead wire conductor through the terminal hole and then
conduct soldering.
Make sure that the temperature of the soldering iron tip does
not exceed 300°C, and complete the soldering within 3
seconds. Do not apply any external force for 1 minute after
soldering.
Soldering at an excessively high temperature or soldering for
more than 3 seconds may deteriorate the characteristics of the
Switch.
In case of automatic soldering, please do not apply the heat
beyond 260°C within 5 seconds. Pay careful attention so that
flux or solder liquid does not flow over the edge of the PCB
panel.
●Side-actuated (Cam/Dog) Operation
●Operating Body
• Use an operating body with low frictional resistance and of a
shape that will not interfere with the sealing rubber, otherwise
the plunger may be damaged or the sealing may deteriorate.
●Handling
• Do not handle the Switch in a way that may cause damage to
the sealing rubber.
• When handling the Switch, ensure that pressure is not applied to
the posts in the directions shown in the following diagram. Also,
ensure that uneven pressure or pressure in a direction other than
the operating direction is not applied to the Actuator as shown in
the following diagram. Otherwise, the post, Actuator, or Switch
may be damaged, or the service life may be reduced.
• When using a cam or dog to operate the Switch, factors such
as the operating speed, operating frequency, push-button
indentation, and material and shape of the cam or dog will
affect the durability of the Switch. Confirm performance
specifications under actual operating conditions before using
the Switch in applications.
7
D2GW
●Wiring Molded Lead Wire Models
• When wiring molded lead wire models, ensure that there is no
weight applied on the wire or that there are no sharp bends
near the parts where the wire is drawn out.
Otherwise, damage to the Switch or deterioration in the
sealing may result.
●Using Micro Loads
• Even when using micro load models within the operating
range, if inrush/surge current occurs, it may increase the
contact wear and so decrease durability. Therefore, insert a
contact protection circuit where necessary.
8
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2021 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. B148-E1-02
0821(0621)