Sealed Subminiature Basic Switch
D2SW-P
Sealed Basic Switch with Simplified
Construction, Mounting Compatible with
SS and D2SW Series.
• Sealed to IEC IP67.
• Switch rating of 2A at 250 VAC possible with a single-leaf
movable spring. Models for micro loads are also available.
• Solder, quick-connect terminals (#110), PCB terminals and
molded lead wires are available. Even-pitched PCB
terminals are also standardized.
Ordering Information
Rating Actuator
2A
0.1A
Terminal
Solder
terminals
Quick-connect
terminals (#110)
PCB terminals
Uneven pitch
Even pitch
Molded lead
wires
Pin plunger
D2SW-P2H
D2SW-P2T
D2SW-P2D
D2SW-P2B
D2SW-P2M
Hinge lever
D2SW-P2L1H
D2SW-P2L1T
D2SW-P2L1D
D2SW-P2L1B
D2SW-P2L1M
Hinge roller lever
D2SW-P2L2H
D2SW-P2L2T
D2SW-P2L2D
D2SW-P2L2B
D2SW-P2L2M
Simulated roller lever
D2SW-P2L3H
D2SW-P2L3T
D2SW-P2L3D
D2SW-P2L3B
D2SW-P2L3M
Pin plunger
D2SW-P01H
D2SW-P01T
D2SW-P01D
D2SW-P01B
D2SW-P01M
Hinge lever
D2SW-P01L1H
D2SW-P01L1T
D2SW-P01L1D
D2SW-P01L1B
D2SW-P01L1M
Hinge roller lever
D2SW-P01L2H
D2SW-P01L2T
D2SW-P01L2D
D2SW-P01L2B
D2SW-P01L2M
Simulated roller lever
D2SW-P01L3H
D2SW-P01L3T
D2SW-P01L3D
D2SW-P01L3B
D2SW-P01L3M
Note: Consult your OMRON sales representative for details on SPST-NO and SPST-NC models.
Model Number Legend
D2SW-P
1 2 3 4
1.
Ratings
2:
2 A at 250 VAC
01: 0.1 A at 30 VDC
2.
Actuator
None: Pin plunger
L1:
Hinge lever
L2:
Hinge roller lever
L3:
Simulated roller lever
3.
Contact Form
None: SPDT
-2:
SPST-NC*
-3:
SPST-NO*
*Lead wire versions only
4.
Terminals
H:
T:
D:
B:
M:
Sealed Subminiature Basic Switch
Solder terminals
Quick-connect terminals (#110)
PCB terminals (Uneven pitch)
PCB terminals (even pitch)
Molded lead wires
D2SW-P
201
Specifications
■ Characteristics
Item
Model
D2SW-P2
D2SW-P01
Operating speed
0.1 mm to 500 mm/s (pin plunger models)
Operating frequency
Mechanical: 120 operations/min max.
Electrical: 20 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
Terminal models: 50 mΩ max.
Molded lead wire models: 100 mΩ max.
Terminal models: 100 mΩ max.
Molded lead wire models: 150 mΩ max.
Dielectric strength (see note 2)
1,000 VAC, 50/60 Hz for 1 min. between
terminals of the same polarities
600 VAC, 50/60 Hz for 1 min. between
terminals of the same polarities
1,500 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 3)
Destruction: 1,000 m/s2 (approx. 100 G) max.
Malfunction: 300 m/s2 (approx. 30 G) max.
Degree of protection
IEC IP67 (excluding the terminals on terminal models)
Degree of protection against electric shock Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-20°C to 70°C (at 60% RH max.) with no icing
Ambient operating humidity
85% max. (for 5°C to 35°C)
Life expectancy
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 50,000 operations min.
(20 operations/min.)
Weight
Approx. 2 g (pin plunger models with terminals)
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 200,000 operations min.
(20 operations/min.)
Note: 1. The data given above are initial values.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values
apply at the total travel position. Contact opening or closing time is within 1ms.
■ Ratings
■ Contact Specifications
Model
Rated voltage
Resistive load
Item
D2SW-P2
D2SW-P01
D2SW-P2
30 VDC
2A
Specification
Rivet
Crossbar
Material
Silver alloy
Gold alloy
Gap (standard value)
0.5 mm
250 VAC
D2SW-P01
30 VDC
0.1 A
125 VAC
Minimum applicable load 160 mA at 5 VDC 1 mA at 5 VDC
(see note)
Note: The ratings values apply under the following test conditions.
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 20 operations/min.
■ Approved Standards
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60%
(λ60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Consult your OMRON sales representative for specific models with
standard approvals.
■ Contact Form
UL Recognized
CSA Certified
SPDT
Rated voltage
D2SW-P2
D2SW-P01
125 VAC
250 VAC
—
2A
0.1 A
—
30 VDC
2A
0.1 A
COM NO NC
(Black) (Blue) (Red)
SPST-NC
SPST-NO
(wire models, only)
(wire models, only)
COM
(Black)
NC
(Red)
COM NO
(Black) (Blue)
Note: Lead wire colors are indicated in parentheses.
202
Sealed Subminiature Basic Switch
D2SW-P
Dimensions
■ Terminals
Note: 1. All units are in millimeters unless otherwise indicated.
2. Terminal plate thickness is 0.5 mm for all models.
Solder Terminals
C
Quick-connect Terminals (#110)
NC
NC
3.3±0.1
7.3
3.3±0.1
11
Three, 1.6-dia. Holes
3.2
2.15
0.5
8.55
7.1
0.5
3-2.8
6.4±0.2
15.5
7.6±0.2
6.4±0.2
7.6±0.2
5.15 9.5±0.1
19.8±0.2
5.15 9.5±0.1
19.8±0.2
PCB Terminals (Even pitch)
PCB Terminals (Uneven pitch)
1.8
3.3±0.1
1.8
3.3±0.1
3.9
3.9
1.85
3-1.2
3-0.8
8.8±0.2
0.5
16.1±0.2
6.4±0.2
5.15 9.5±0.1
19.8±0.2
PCB Mounting Dimensions (Reference)
16.1±0.1
8.8±0.1
3-1.2
3-0.8
1.3
1.3
5.15 9.5±0.1
7.62±0.2 7.62±0.2
19.8±0.2
0.5
6.4±0.2
PCB Mounting Dimensions (Reference)
7.62±0.1 7.62±0.1 Three, 1.35 to 1.5 dia.
Three,-1.35 to 1.5 dia.
Molded Lead Wires
9.2
6.4±0.2
300±10
Normally closed
terminal (red)
Common terminal (black)
Insulator
Stranded annealed
copper wites
0.7
(5)
5.15 9.5±0.1
Normally open
terminal (blue)
21.2
■ Mounting Holes
All switches may be panel mounted using M2.3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.23 to 0.26 N·m
Exceeding the specified torque may result in deterioration of the
sealing or damage.
Two, M2.3 screw hole
9.5±0.1
Sealed Subminiature Basic Switch
D2SW-P
203
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and drawings are for solder terminal models. Refer to Terminals section for details on models with quick-connect
terminals (#110) or PCB terminals or molded lead wires.
3. The operating characteristics are for operation in the A direction ( ).
.
Pin Plunger Models
D2SW-P2@@
D2SW-P01@@
7.55±0.2
A
PT
1.8 dia.
2.5±0.07 dia.
2.35 +0.075
−0.05 dia.
OP
6.9 7.7
2.35+0.075
−0.05
3.3±0.1
7.3
3.2
2.15
Three, 1.6 dia. holes
8.55
15.5
0.5
OF max.
RF min.
183 gf
20 gf
PT max.
OT min.
MD max.
0.6 mm
0.4 mm
0.15 mm
OP
8.4±0.3 mm
6.4±0.2
5.15 9.5±0.1
19.8±0.2
Hinge Lever Models
D2SW-P2L1@@
D2SW-P01L1@@
A
t=0.3 Stainless-steel lever
14.5±0.6
2.35 +0.075
−0.05 dia.
2.5±0.07 dia.
OP FP
6.9 7.7
2.35 +0.075
−0.05
3.3±0.1
7.3
3.2
2.15
Three, 1.6 dia. holes
8.55
15.5
5.15 9.5±0.1
19.8±0.2
OF max.
RF min.
61 gf
5 gf
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
13.6 mm
8.8±0.8 mm
OF max.
RF min.
61 gf
5 gf
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
19.3 mm
14.5±0.8 mm
OF max.
RF min.
61 gf
5 gf
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
15.5 mm
10.7±0.8 mm
0.5
6.4±0.2
Hinge Roller Lever Models
dia. 4.8 x 3.2
Polyacetal resin roller
A
D2SW-P2L2@@
D2SW-P01L2@@
t=0.3 Stainless-steel lever
14.5±0.6
2.5±0.07 dia.
2.35 +0.075
-0.05
dia. FP
OP
6.9 7.7
2.35 +0.075
-0.05
3.3±0.1
7.3
3.2
2.15
Three, 1.6 dia. holes
8.55
15.5
5.15 9.5±0.1
19.8±0.2
0.5
6.4±0.2
Simulated Roller Lever Models
D2SW-P2L3@@
D2SW-P01L3@@
A
t=0.3 Stainless-steel lever
15.8±0.6
R1.3
2.35 +0.075
−0.05 dia.
2.5±0.07 dia.
6.9 7.7
2.35 +0.075
−0.05
3.3±0.1
7.3
3.2
2.15
204
OP FP
8.55
15.5
5.15 9.5±0.1
19.8±0.2
Sealed Subminiature Basic Switch
Three, 1.6 dia. holes
0.5
6.4±0.2
D2SW-P
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
Mounting
Operating Stroke Setting
Turn OFF the power supply before mounting or removing the Switch,
wiring, or performing maintenance or inspection. Failure to do so may
result in electric shock or burning.
Set the operating stroke so that the actuator is completely disengaged when the switch is in the free position (FP), and is pushed to a
point between 60% and 90% of the OT distance after the switch is
operated.
Mount the Switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the Switch, resulting in faulty operation or
damage.
Insufficient or excessive pushing of the actuator may result in
decreased switch durability or damage to the switch.
Using Micro Loads
Use an operating body with low frictional resistance and of a shape
that will not interfere with the sealing rubber, otherwise the plunger
may be damaged or the sealing may deteriorate.
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
With the pin plunger models, set the Switch so that the plunger can
be pushed in from directly above. Since the plunger is covered with a
rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability
Voltage (V)
Operating Body
30
0.16mA
26mA
100mA
24
.
Correct
Incorrect
Incorrect
Operating range for
micro load models
D2SW-P01
Operating
range for
general-load
models
D2SW-P2
12
5
Inoperable
range
1mA
Handling
Do not handle the Switch in a way that may cause damage to the
sealing rubber. When handling the Switch, ensure that uneven pressure or, as shown in the following diagram, pressure in a direction
other than the operating direction is not applied to the Actuator, otherwise the Actuator or Switch may be damaged, or durability may be
decreased.
100mA 160mA
0
0.1
1
10
100
1,000
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
Wiring Molded Lead Wire Models
When wiring molded lead wire models, ensure that there is no weight
on the wire or that there are no sharp bends near the parts where the
wire is drawn out. Otherwise, damage to the Switch or deterioration
in the sealing may result.
Sealed Subminiature Basic Switch
D2SW-P
205
■ Cautions
Degree of Protection
Connecting to Terminals
Do not use this product in water. Although these models satisfy the
test conditions for the standard given below, this test is to check the
ingress of water into the switch enclosure after submerging the
Switch in water for a given time. Satisfying this test condition does
not mean that the Switch can be used in water.
IEC 60529: 2001 Degrees of protection provided by enclosures (IP
Code)
Code: IP67 (The test to meet the standard checks for water intrusion
after immersion for 30 minutes.)
Do not operate the Switch when it is exposed to water spray, or when
water drops adhere to the Switch surface, or during sudden temperature changes, otherwise water may intrude into the interior of the
Switch due to a suction effect.
Prevent the Switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of Switch materials may result.
Connecting to Solder Terminals
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and the conduct soldering.
Make sure that the temperature at the tip of the soldering iron is
350 to 400°C. Do not take more than 3 seconds to solder the switch
terminal, and do not impose external force on the terminal for 1 min.
after soldering. Improper soldering involving an excessively high temperature or excessive soldering time may deteriorate the characteristics of the Switch.
Connecting to Quick-connect Terminals
Wire the quick-connect terminals (#110) with receptacles. Insert the
terminals straight into the receptacles. Do not impose excessive
force on the terminal in the horizontal direction, otherwise the terminal may be deformed or the housing may be damaged.
Connecting to PCB Terminal Boards
Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease, otherwise faulty contact may result due to
the generation of silicon oxide.
When using automatic soldering baths, we recommend soldering at
260±5°C within 5 seconds. Make sure that the liquid surface of the
solder does not flow over the edge of the board.
The environment-resistant performance of the switch differs
depending on operating loads, ambient atmospheres, and installation
conditions, etc. Please perform an operating test of the switch in
advance under actual usage conditions.
When soldering by hand, as a guideline, solder with a soldering iron
with a tip temperature of 350 to 400°C within 3 seconds, and do not
apply any external force for at least 1 minute after soldering. When
applying solder, keep the solder away from the case of the Switch
and do not allow solder or flux to enter the case.
Side-actuated (Cam/Dog) Operation
When using a cam or dog to operate the Switch, factors such as the
operating speed, operating frequency, push-button indentation, and
material and shape of the cam or dog will affect the durability of the
Switch. Confirm performance specifications under actual operation
conditions before using the Switch in applications.
206
Sealed Subminiature Basic Switch
D2SW-P
MEMO
Sealed Subminiature Basic Switch
D2SW-P
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X303-E-1
11/10
Specifications subject to change without notice
Sealed Subminiature Basic Switch