D2VW
Sealed Miniature Basic Switch
Sealed Miniature Basic Switch
Conforms to IP67 (Molded Lead Wire
Type Only)
Use of epoxy resin assures stable sealing,
making this switch ideal for places subject to
water spray or excessive dust.
V-series internal mechanism assures high
precision and long life.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial
equipment, which require high environmental
resistance.
Models available with conformance to safety
standards, including UL, CSA and VDE.
WRC
Ordering Information
Model Number Legend
D2VW-jj-jj
1
2
3
4
1.
Ratings
5: 5 A at 250 VAC
01: 0.1 A at 30 VDC
2.
Actuator
None: Pin plunger
L1A:
Short hinge lever
L1:
Hinge lever
L1B:
Long hinge lever
L3:
Simulated roller lever
L2A:
Short hinge roller lever
L2:
Hinge roller lever
3.
Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
4.
Terminals
None, HS: Solder terminals
(HS for UL and CSA approval.)
M, MS:
Molded lead wires (MS for UL and CSA approval)
List of Models
Actuator
Pin plunger
p g
Short hinge
g lever
Hinge
g Lever
Long
g hinge
g lever
Simulated roller lever
Short hinge
g roller lever
Hinge roller lever
Note:
Model
5A
0.1 A
Solder terminals
D2VW-5-1
D2VW-01-1
Molded lead wires
D2VW-5-1M
D2VW-01-1M
Solder terminals
D2VW-5L1A-1
D2VW-01L1A-1
Molded lead wires
D2VW-5L1A-1M
D2VW-01L1A-1M
Solder terminals
D2VW-5L1-1
D2VW-01L1-1
Molded lead wires
D2VW-5L1-1M
D2VW-01L1-1M
Solder terminals
D2VW-5L1B-1
D2VW-01L1B-1
Molded lead wires
D2VW-5L1B-1M
D2VW-01L1B-1M
Solder terminals
D2VW-5L3-1
D2VW-01L3-1
Molded lead wires
D2VW-5L3-1M
D2VW-01L3-1M
Solder terminals
D2VW-5L2A-1
D2VW-01L2A-1
Molded lead wires
D2VW-5L2A-1M
D2VW-01L2A-1M
Solder terminals
D2VW-5L2-1
D2VW-01L2-1
Molded lead wires
D2VW-5L2-1M
D2VW-01L2-1M
1. The standard lengths of the molded lead wires (AV0.75f) of models incorporating them are 30 cm.
2. Consult your OMRON sales representative for details on SPST-NO and SPST-NC models.
3. Add “HS” or “MS” to the end of the model number for the UL/CSA-approved version (e.g., D2VW-01-1 → D2VW-01-1HS).
Consult your OMRON sales representative for details.
214
D2VW
D2VW
Specifications
Ratings
Item
Model
D2VW-5
D2VW-01
Note:
Resisteve load
Rated voltage
250 VAC
5A
125 VAC
5A
30 VDC
5A
125 VAC
0.1 A
30 VDC
0.1 A
The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
Switching Capacity per Load (Reference Values)
Non-inductive load
Resistive load
Model
D2VW-5
Note:
Voltage
NC
Inductive load
Lamp load
NO
NC
Inductive load
NO
NC
125 VAC
5A
0.5 A
4A
250 VAC
5A
0.5 A
4A
30 VDC
5A
3A
4A
125 VDC
0.4 A
0.1 A
0.4 A
NO
1. The above current ratings are the values of the steady-state current.
2. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
Characteristics
Operating speed
0.1 mm to 1 m/s (pin plunger models)
Operating frequency
Mechanical: 300 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance (initial value)
50 mΩ max. (100 mΩ max. for molded lead wire models)
Dielectric strength (see note 2)
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying
metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 3)
Destruction: 1,000 m/s2 {approx. 100G} max.
Malfunction: 300 m/s2 {approx. 30G} max.
Durability (see note 4)
Mechanical: 10,000,000 operations min. (60 operations/min)
Electrical: D2VW-5 models: 100,000 operations min. (30 operations/min)
D2VW-01 models: 1,000,000 operations min. (30 operations/min)
Degree of protection
IEC IP67 (excluding the terminals on terminal models)
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature (see note 5)
–40°C to 85°C (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity
95% max. (for 5°C to 35_C)
Weight
Approx. 7 g (pin plunger models with terminals)
Note:
1. The data given above are initial values.
2. The dielectric strength shown in the table indicates the value for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
they apply at the total travel position.
4. For testing conditions, consult your OMRON sales representative.
5. The operating temperature of the lead wire (AV0.75f) for the molded lead wire model is between –40°C to 85°C.
215
D2VW
D2VW
Approved Standards
Contact Specifications
Consult your OMRON sales representative for specific models with
standard approvals.
Item
Contact
UL1054 (File No. E41515)/
CSA C22.2 No.55 (File No. LR21642)
Rated voltage
D2VW-5
3A
3A
0.1 A
---
30 VDC
---
0.1 A
Rated voltage
D2VW-5
125 VAC
250 VAC
Crossbar
Material
Silver alloy
Gold alloy
Gap
(standard value)
0.5 mm
NC
15 A max.
---
NO
15 A max.
---
Minimum applicable load
(see note)
160 mA
at 5 VDC
1 mA
at 5 VDC
Inrush
currentt
EN61058-1 (File No. 104068, VDE approval)
D2VW-01
--3A
D2VW-01
Rivet
D2VW-01
125 VAC
250 VAC
D2VW-5
Specification
Note:
For more information on the minimum applicable load,
refer to Using Micro Loads on page 219.
0.1 A
---
Testing conditions:
25E3 (25,000 operations), T85 (0°C to 85°C) for D2VW-5,
1E5 (100,000 operations), T85 (0°C to 85°C) for D2VW-01
Contact Form
SPDT
SPST-NC
NC (red)
NO (blue)
COM (black)
Note:
SPST-NO
NC (red)
NO (blue)
COM (black)
COM (black)
Colors in parentheses indicate lead wire colors.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Terminals
The pin plunger model is shown here as a typical example. Operating characteristics and dimensions of the actuator section are the same as for
the molded lead wire models.
Molded Lead Wires
Solder/Quick Connect Terminals
2.4 dia. hole
1.3 dia. hole
AV 0.75f Lead wire (red)*
10.3
AV 0.75f Lead wire (blue)*
AV 0.75f Lead wire (black)*
4.8
1.2
5.2
8.4
0.5
2.5
5.2
5.2
t=0.5
Three, solder terminals
33
41.4
Mounting Holes
Two, 3.1-dia. mounting holes or
M3 screw holes
10.3 ± 0.1
22.2 ± 0.1
216
33
10.3
300±10
* UL/CSA approved models have UL approved wiring.
22.2±0.1
2.8
(5)
22.2±0.1
2.8
D2VW
D2VW
Dimensions and Operating Characteristics
Note:
1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
3. The operating characteristics are for operation in the A direction ( ).
Pin Plunger Models
2.4 dia. hole
1.3 dia. hole
OF max.
1.96 N {{200 g
gf}}
RF min.
0.29 N {30 gf}
PT max.
1.2 mm
OT min.
1.0 mm
MD max.
0.4 mm
OP
14.7±0.4 mm
OF max.
1.96 N {{200 g
gf}}
RF min.
0.20 N {20 gf}
PT max.
1.6 mm
OT min.
0.8 mm
MD max.
0.5 mm
OP
15.2±0.5 mm
Hinge Lever Models
OF max.
1.18 N {{120 g
gf}}
D2VW-01L1-1M
D2VW-5L1-1M
RF min.
0.15 N {15 gf}
PT max.
4.0 mm
OT min.
1.6 mm
MD max.
0.8 mm
OP
15.2±1.2 mm
Long Hinge Lever Models
OF max.
0.59 N {{60 g
gf}}
D2VW-01L1B-1M
D2VW-5L1B-1M
RF min.
0.05 N {5 gf}
PT max.
9.0 mm
OT min.
3.2 mm
MD max.
2.0 mm
OP
15.2±2.6 mm
D2VW-01-1
D2VW-5-1
10.3
4.8
1.2
5.2
20.2±0.25
A
2.5 dia.
2.8
PT
OP
8.4
+0.13
3.1 –0.03 dia. holes
0.5
15.9 10.3±0.1
2.5
5.2
5.2
3.2±0.1 dia.
+0.13
3.1 –0.03
22.2±0.1
2.8
t=0.5
Three, solder terminals
33
41.4
Short Hinge Lever Models
D2VW-01L1A-1M
D2VW-5L1A-1M
A
4.3
24.3±0.8
t=0.5* 5
PT
OP
15.9
*Stainless-steel lever
A
35.6±0.8
t=0.5*
10.3
4.3
5
PT
OP 15.9
*Stainless-steel lever
A
59.4±0.8
t=0.5*
10.3
5
4.3
PT
OP
15.9
*Stainless-steel lever
10.3
217
D2VW
D2VW
Simulated Roller Lever Models
D2VW-01L3-1M
D2VW-5L3-1M
A
PT
32.6±0.8
3.5R
t=0.5*
4.3
5
OP
15.9
D2VW-01L2A-1M
D2VW-5L2A-1M
4.8 dia.
4.8 **
PT
24.3±0.8
A
20.1±0.8
5
t=0.5*
7.2
OP
15.9
*Stainless-steel lever
**Oil-less polyacetal resin roller
A
34±0.8
4.8 dia. 4.8 **
PT
5
7.2
t=0.5*
OP
15.9
*Stainless-steel lever
**Oil-less polyacetal resin roller
218
RF min.
0.15 N {15 gf}
PT max.
4.0 mm
OT min.
1.6 mm
MD max.
0.8 mm
OP
18.7±1.2 mm
OF max.
2.25 N {{230 g
gf}}
RF min.
0.20 N {20 gf}
PT max.
1.6 mm
OT min.
0.8 mm
MD max.
0.5 mm
OP
20.7±0.6 mm
OF max.
1.18 N {{120 g
gf}}
RF min.
0.15 N {15 gf}
PT max.
4.0 mm
OT min.
1.6 mm
MD max.
0.8 mm
OP
20.7±1.2 mm
10.3
Hinge Roller Lever Models
D2VW-01L2-1M
D2VW-5L2-1M
1.18 N {{120 g
gf}}
10.3
*Stainless-steel lever
Short Hinge Roller Lever Models
OF max.
10.3
D2VW
D2VW
Precautions
Refer to pages 26 to 31 for common precautions.
Cautions
Correct Use
Mounting
Degree of Protection
Do not use the Switch underwater. The Switch was tested and found
to meet the conditions necessary to meet the following standard.
The test checks for water intrusion after immersion for a specified
time period. The test does not check for switching operation underwater.
IEC Publication 529, degree of protection IP67.
Protection Against Chemicals
Use M3 mounting screws with plane washers or spring washers to
securely mount the Switch. Tighten the screws to a torque of 0.39 to
0.59 N S m {4 to 6 kgf S cm}.
Operating Body
With the pin plunger models, set the Switch so that the plunger can
be pushed in from directly above. Since the plunger is covered with
a rubber cap, applying a force from lateral directions may cause
damage to the plunger or reduction in the sealing capability.
Prevent the Switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of Switch materials may result.
Correct
Incorrect
Incorrect
Handling
Handle the Switch carefully so as not to break the sealing rubber of
the plunger.
Using Micro Loads
Voltage (V)
Using a model for ordinary loads to open or close the contact of a
micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load
models within the operating range shown below, if inrush current occurs when the contact is opened or closed, it may increase contact
wear and so decrease durability. Therefore, insert a contact protection circuit where necessary.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability level of 60% (λ 60). The equation, λ 60 = 0.5 10–6/operations indicates that the estimated malfunction rate is less than 1/2,000,000
operations with a reliability level of 60%.
Operating range
for micro load
models D2VW-01
Operating
range for
general-load
models
D2VW-05
Inoperable
range
Current (mA)
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C095-E1-03C
219