0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D2VW-5-1M

D2VW-5-1M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    D2VW-5-1M

  • 数据手册
  • 价格&库存
D2VW-5-1M 数据手册
D2VW Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) D 2 V W O Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive dust. O V-series internal mechanism assures high precision and durability. The mounting is the same as of the V models. O Ideal for automobiles, agricultural machines, large-scale home appliances, and industrial equipment, which require high environmental resistance. RoHS Compliant Model Number Legend 1  2  3  4  5 D2VW -  1. Ratings 5 : 250 VAC 5 A 01 : 30 VDC 0.1 A 2. Actuator None : Pin plunger L1A : Short hinge lever L1 : Hinge lever L1B : Long hinge lever L2A : Short hinge roller lever 4. Terminals None, HS : Solder terminals M, MS : Molded lead wires Note: UL/cUL approved versions are available. In this case, HS, MS will be added to the end of the model numbe UL/cUL approved models have UL approved wiring (AWG20 UL1015). Consult your OMRON sales representative for details. 5. Length of the molded lead wire None : 300 mm -0 : 1,000 mm L2 : Hinge roller lever L3 : Simulated roller hinge lever 3. Contact form -1 : SPDT -2 : SPST-NC -3 : SPST-NO 1 D2VW Sealed Miniature Basic Switch List of Models Ratings Actuator Terminals Solder terminals Molded lead wires (300 mm) D 2 V W Molded lead wires (1,000 mm) Solder terminals Short hinge lever Molded lead wires (300 mm) SPDT D2VW-5-1 D2VW-01-1 D2VW-5-2 D2VW-01-2 D2VW-5-3 D2VW-01-3 SPDT D2VW-5-1M D2VW-01-1M SPST-NC D2VW-5-2M D2VW-01-2M SPST-NO D2VW-5-3M D2VW-01-3M D2VW-5-1M-0 D2VW-01-1M-0 SPDT SPDT D2VW-5L1A-1 D2VW-01L1A-1 SPST-NC D2VW-5L1A-2 D2VW-01L1A-2 SPST-NO D2VW-5L1A-3 D2VW-01L1A-3 SPDT D2VW-5L1A-1M D2VW-01L1A-1M SPST-NC D2VW-5L1A-2M D2VW-01L1A-2M SPST-NO Molded lead wires (1,000 mm) Solder terminals SPDT Molded lead wires (300 mm) Molded lead wires (1,000 mm) Solder terminals Molded lead wires (300 mm) D2VW-5L1-1 D2VW-01L1-1 D2VW-5L1-2 D2VW-01L1-2 D2VW-5L1-3 D2VW-01L1-3 SPDT D2VW-5L1-1M D2VW-01L1-1M SPST-NC D2VW-5L1-2M D2VW-01L1-2M SPST-NO D2VW-5L1-3M D2VW-01L1-3M D2VW-5L1-1M-0 D2VW-01L1-1M-0 SPDT SPDT D2VW-5L1B-1 D2VW-01L1B-1 SPST-NC D2VW-5L1B-2 D2VW-01L1B-2 D2VW-5L1B-3 D2VW-01L1B-3 SPDT D2VW-5L1B-1M D2VW-01L1B-1M SPST-NC D2VW-5L1B-2M D2VW-01L1B-2M SPST-NO Molded lead wires (1,000 mm) Solder terminals SPDT Molded lead wires (300 mm) Molded lead wires (1,000 mm) Solder terminals Molded lead wires (300 mm) Molded lead wires (1,000 mm) Solder terminals D2VW-5L2A-1 D2VW-01L2A-1 D2VW-5L2A-2 D2VW-01L2A-2 D2VW-5L2A-3 D2VW-01L2A-3 SPDT D2VW-5L2A-1M D2VW-01L2A-1M SPST-NC D2VW-5L2A-2M D2VW-01L2A-2M SPST-NO D2VW-5L2A-3M D2VW-01L2A-3M SPDT D2VW-5L2A-1M-0 D2VW-01L2A-1M-0 SPDT D2VW-5L2-1 D2VW-01L2-1 SPST-NC D2VW-5L2-2 D2VW-01L2-2 D2VW-5L2-3 D2VW-01L2-3 SPDT D2VW-5L2-1M D2VW-01L2-1M SPST-NC D2VW-5L2-2M D2VW-01L2-2M SPST-NO D2VW-5L2-3M D2VW-01L2-3M D2VW-5L2-1M-0 D2VW-01L2-1M-0 SPDT SPDT D2VW-5L3-1 D2VW-01L3-1 SPST-NC D2VW-5L3-2 D2VW-01L3-2 SPST-NO Simulated roller hinge lever Molded lead wires (300 mm) Molded lead wires (1,000 mm) D2VW-01L1B-3M D2VW-01L1B-1M-0 SPDT SPST-NO Hinge roller lever D2VW-5L1B-3M D2VW-5L1B-1M-0 SPST-NC SPST-NO Short hinge roller lever D2VW-01L1A-3M D2VW-01L1A-1M-0 SPDT SPST-NO Long hinge lever D2VW-5L1A-3M D2VW-5L1A-1M-0 SPST-NC SPST-NO Hinge lever D2VW-5L3-3 D2VW-01L3-3 SPDT D2VW-5L3-1M D2VW-01L3-1M SPST-NC D2VW-5L3-2M D2VW-01L3-2M SPST-NO D2VW-5L3-3M D2VW-01L3-3M D2VW-5L3-1M-0 D2VW-01L3-1M-0 SPDT Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately) 2 0.1 A SPST-NC SPST-NO Pin plunger 5A Contact form Refer to "Basic Switch Common Accessories" D2VW Sealed Miniature Basic Switch OSafety Standard Approved Models Ratings Actuator Terminals Pin plunger Short hinge lever Hinge lever Long hinge lever Hinge roller lever Simulated roller lever 0.1A Solder terminals D2VW-5-1HS D2VW-01-1HS Molded lead wires (300 mm) D2VW-5-1MS D2VW-01-1MS Solder terminals D2VW-5L1A-1HS D2VW-01L1A-1HS Molded lead wires (300 mm) D2VW-5L1A-1MS D2VW-01L1A-1MS Solder terminals D2VW-5L1-1HS D2VW-01L1-1HS Molded lead wires (300 mm) D2VW-5L1-1MS D2VW-01L1-1MS Solder terminals D2VW-5L1B-1HS D2VW-01L1B-1HS Molded lead wires (300 mm) Short hinge roller lever 5A Contact form SPDT D2VW-5L1B-1MS D2VW-01L1B-1MS Solder terminals D2VW-5L2A-1HS D2VW-01L2A-1HS Molded lead wires (300 mm) D2VW-5L2A-1MS D2VW-01L2A-1MS Solder terminals D2VW-5L2-1HS D2VW-01L2-1HS Molded lead wires (300 mm) D2VW-5L2-1MS D2VW-01L2-1MS Solder terminals D2VW-5L3-1HS D2VW-01L3-1HS Molded lead wires (300 mm) D2VW-5L3-1MS D2VW-01L3-1MS D 2 V W Contact Form OSPDT OSPST-NC NC (Red) NO (Blue) COM (Black) OSPST-NO NC (Red) NO (Blue) COM (Black) COM (Black) The color in parentheses indicates the color of the lead wire. Contact Specifications Item Model D2VW-5 models D2VW-01 models Rivet Crossbar Specification Contact Material Silver alloy Gap (standard value) Inrush current Gold alloy 15A max. - NO 15A max. - 5 VDC 160 mA 5 VDC 1 mA Please refer to "Using Micro Loads" in "OPrecautions" for more information on the minimum applicable load. Ratings Item Model D2VW-5 models D2VW-01 models Rated voltage Resistive load 250 VAC 125 VAC 5A 5A 30 VDC 5A 125 VAC 0.1 A 30 VDC 0.1 A UL (UL61058-1)/cUL (CSA C22.2 No.61058-1) The terminal specification for models with UL/cUL safety standard certification is “HS” or “MS.” Rated voltage 0.5 mm NC Minimum applicable load (reference value) * * Approved Safety Standards Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 30 operations/min D2VW-5 D2VW-01 125 VAC 250 VAC Model 3A 3A 0.1 A - 30 VDC - 0.1 A VDE (EN61058-1) The models in the List of Models on the previous page are not certified for VDE standards. Contact your OMRON representative if you require certified models. Rated voltage 125 VAC 250 VAC Model D2VW-5 D2VW-01 3A 0.1 A - Testing conditions: D2VW-5 25E3 (25,000 operations) T55 (0 to 55°C) D2VW-01 1E5 (100,000 operations) T85 (0 to 85°C) Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Micro Switch Common Accessories" 3 D2VW Sealed Miniature Basic Switch Characteristics Item Mounting Holes (Unit: mm) Model D2VW-5 models Permissible operating speed Permissible operating frequency Mechanical Electrical 60 operations/min Terminal models 50 mΩ max. 200 mΩ max. Between terminals of the same polarity 1,000 VAC 50/60 Hz for 1 min Between current-carrying metal parts and ground 1,500 VAC 50/60 Hz for 1 min Between terminals and non-current-carrying metal parts 1,500 VAC 50/60 Hz for 1 min 10 to 55 Hz, 1.5 mm double amplitude Destruction 1,000m/s2 {approx. 100G} max. Malfunction *2 300m/s2 {approx. 30G} max. Mechanical Durability *3 Degree of protection 22.2±0.1 100 mΩ max. Vibration Malfunction resistance *2 Shock resistance 10.3±0.1 100 MΩ min. (500 VDC with insulation tester) Contact Molded lead wire resistance terminals (300mm) (initial value) Molded lead wire terminals (1,000mm) Dielectric strength *1 Electrical Terminal models 10,000,000 operations min. (60 operations/min) 100,000 operations min. (30 operations/min) IEC IP67 Degree of protection against electric shock Class l Proof tracking index (PTI) 175 –40°C to +85°C (at ambient humidity of 60% max.) (with no icing or condensation) 95% max. (for +5°C to +35°C) Ambient operating humidity Weight 1,000,000 operations min. (30 operations/min) IEC IP67 (excluding the terminals on terminal models) Molded lead wire models Ambient operating temperature 2-3.1 dia. mounting holes or M3 screw holes 300 operations/min Insulation resistance D 2 V W D2VW-01 models 0.1mm to 1m/s (for pin plunger models) Approx. 7 g (for pin plunger models with terminals) Note. The data given above are initial values. *1. The dielectric strength shown in the table indicates the value for models with a Separator (refer to "Basic Switch Common Accessories"). *2. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is 1 ms max. *3. For testing conditions, consult your OMRON sales representative. Dimensions (Unit: mm) and Operating Characteristics The illustrations and dimensions are for pin plunger models. Dimensions and operation characteristics of other actuator models are the same as those of molded lead wires models. Models with solder terminals OPin Plunger Models D2VW-5-1 D2VW-01-1 2.4 dia. holes 1.3 dia. holes 10.3 4.75 1.2 5.2 8.4 PT 2.8 OP A 20.2±0.25 2.5 dia. 3.1+0.13 -0.03 dia. holes 0.5 2.5 5.2 15.9 10.3±0.1 5.2 3.1+0.13 -0.03 2.8 3.2±0.1 dia. 22.2±0.1 33 t0.5 3-Solder terminals Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 4 Operating Force Releasing Force OF RF Max. Min. 1.96 N {200 gf} 0.29 N {30 gf} Pretravel Overtravel Movement Differential PT OT MD Max. Min. Max. 1.2 mm 1.0 mm 0.4 mm Operating Position OP 14.7±0.4 mm D2VW Sealed Miniature Basic Switch The illustration and drawing shown is the SPDT model. SPST-NC model and SPST-NO model are omitted. Models with molded lead wires OPin Plunger Models D2VW-5-1M D2VW-5-1M-0 D2VW-01-1M D2VW-01-1M-0 2.8 OP AV0.75f molded lead wire (red)* 20.20.25 2.5 dia. PT A AV0.75f molded lead wire (blue)* AV0.75f molded lead wire (black)* 3.10.13 -0.03 dia. holes Operating Force Releasing Force 15.9 10.30.1 3.10.13 -0.03 3.20.1 dia. 22.20.1 33 2.8 (5) 10.3 Operating Position 300 mm type 1,000 mm type L 24.3±0.8 PT OP t=0.5* A 300±10 5 35.6±0.8 A t=0.5* OP * UL/cUL approved models have UL approved wiring (AWG20 UL1015). 4.3 Operating Force Releasing Force 5 4.3 A 59.4±0.8 t=0.5* 5 32.6±0.8 A 4.3 Operating Force Releasing Force OF Max. 1.18 N {120 gf} RF Min. 0.15 N {15 gf} OP 4.3 t=0.5* Operating Force Releasing Force OF Max. RF Min. 15.2±1.2 mm 0.59 N {60 gf} 0.05 N {5 gf} 9.0 mm 3.2 mm 2.0 mm Operating Position OP 15.2±2.6 mm Operating Force Releasing Force OF Max. RF Min. 1.18N {120 gf} 0.15N {15 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. OP Operating Position 15.9 * Stainless-steel lever 4.0 mm 1.6 mm 0.8 mm 10.3 5 R3.5 15.2±0.5 mm 10.3 15.9 OSimulated Roller Lever Hinge Models D2VW-5L3-1M PT D2VW-5L3-1M-0 D2VW-01L3-1M D2VW-01L3-1M-0 1.6 mm 0.8 mm 0.5 mm OP Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. * Stainless-steel lever 1.96 N {200 gf} 0.20 N {20 gf} Operating Position Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 15.9 * Stainless-steel lever OP OF Max. RF Min. 10.3 Operating Position OLong Hinge Lever Models D2VW-5L1B-1M PT D2VW-5L1B-1M-0 D2VW-01L1B-1M D2VW-01L1B-1M-0 14.7±0.4 mm 1,000±30 15.9 PT 1.2 mm 1.0 mm 0.4 mm OP Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. * Stainless-steel lever OHinge Lever Models D2VW-5L1-1M D2VW-5L1-1M-0 D2VW-01L1-1M D2VW-01L1-1M-0 Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. L Dimensions OShort Hinge Lever Models D2VW-5L1A-1M D2VW-5L1A-1M-0 D2VW-01L1A-1M D2VW-01L1A-1M-0 OF Max. 1.96 N {200 gf} RF Min. 0.29 N {30 gf} OP 4.0 mm 1.6 mm 0.8 mm 18.7±1.2 mm 10.3 Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 5 D 2 V W D2VW Sealed Miniature Basic Switch Models with molded lead wires OShort Hinge Roller Lever Models D2VW-5L2A-1M D2VW-5L2A-1M-0 *2 4.8×4.8 dia. D2VW-01L2A-1M PT D2VW-01L2A-1M-0 24.3±0.8 20.1±0.8 A 5 7.2 *1 t=0.5 15.9 *1. Stainless-steel lever *2. Polyacetal resin roller OHinge roller lever D2VW-5L2-1M D2VW-5L2-1M-0 D2VW-01L2-1M D2VW-01L2-1M-0 A PT 34±0.8 4.8×4.8 * 2 dia. Operating Position OP Operating Force Releasing Force OF Max. RF Min. 5 7.2 Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. t=0.5 * 1 Operating Position 15.9 *1. Stainless-steel lever *2. Polyacetal resin roller Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 2.25 N {230 gf} 0.20 N {20 gf} 1.6 mm 0.8 mm 0.5 mm 20.7±0.6 mm 10.3 OP 6 OF Max. RF Min. Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. OP D 2 V W Operating Force Releasing Force 10.3 OP 1.18 N {120 gf} 0.15 N {15 gf} 4.0 mm 1.6 mm 0.8 mm 20.7±1.2 mm D2VW Sealed Miniature Basic Switch Precautions +Please refer to "Basic Switches Common Precautions" for correct use. Cautions Correct Use ODegree of Protection OMounting Do not use the Switch underwater. The Switch was tested and found to meet the conditions necessary to meet the following standard, however, the test checks for water intrusion after immersion for a specified time period, not for switching operation underwater. JIS C0920: Degrees of protection provided by enclosures of electrical apparatus (IP Code) IEC 60529: Degrees of protection provided by enclosures (IP Code) Degree of protection: IP67 (check water intrusion after immersion for 30 min submerged 1 m underwater) Use M3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.39 to 0.59 N·m {4 to 6 kgf·cm}. Prevent the Switch from coming into contact with oil or chemicals. Otherwise, damage to or deterioration of Switch materials may result. OSoldering • Connecting to Solder Terminals When soldering the lead wire to the terminal, first insert the lead wire conductor through the terminal hole and then conduct soldering. Complete the soldering at the iron tip temperature between 350 to 400°C within 5 seconds, and do not apply any external force for 1 minute after soldering. Soldering at a excessively high temperature or soldering for more than 5 s may deteriorate the characteristics of the Switch. D 2 V W With the pin plunger models, set the Switch so that the plunger can be pushed in from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. OHandling Handle the Switch carefully so as not to break the sealing rubber. OUsing Micro Loads Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The N-level reference value applies for the minimum applicable load. This value indicates the malfunction reference level for the reliability level of 60% (λ60). (JIS C5003) The equation, λ60=0.5×10-6/operations indicates that the 1 estimated malfunction rate is less than 2,000,000 operations with a reliability level of 60%. Voltage (V) OProtection Against Chemicals OOperating Body 30 26 mA 100 mA 0.16 mA 24 Operating range for micro load models D2VW-01 Operating range for general-load models D2VW-5 12 5 1 mA 100mA 160 mA 0 0.1 1 10 100 1,000 Current (mA) 7 D2VW Sealed Miniature Basic Switch D 2 V W Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Americas https://www.components.omron.com/ Asia-Pacific https://ecb.omron.com.sg/ Korea https://www.omron-ecb.co.kr/ Europe http://components.omron.eu/ China https://www.ecb.omron.com.cn/ Japan https://www.omron.co.jp/ecb/ © OMRON Corporation 2007-2020 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. 8 Cat. No. C095-E1-08 0120 (0207)
D2VW-5-1M 价格&库存

很抱歉,暂时无法提供与“D2VW-5-1M”相匹配的价格&库存,您可以联系我们找货

免费人工找货