0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D3C2220

D3C2220

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON ELECTRONIC COMPONENTS - D3C2220 - Detector Switch, SPDT, Solder, 100 mA, 30 V, 6 mm

  • 数据手册
  • 价格&库存
D3C2220 数据手册
D3C Ultra Subminiature Detection Switch 㧰 Ultra Subminiature Detection Switch with Slide Mechanism and Lever Actuator ● Compact and light weight with 3-mm long stroke. 3 C ● Built-in slide mechanism allows selection of shorting or non-shorting switching timing to match the application. RoHS Compliant Model Number Legend Contact Form 2 0 1 2@ D3C-@ ●SPDT 1. Switching timing 1 : Non-shorting Model 2 : Shorting Model 2. Maximum Operating Force (OF) 1 : 1.28N {130 gf} NO COM NC 3 2 : 0.39N {40 gf} Contact 1.28 N {130 gf} (Standard) 0.39 N {40 gf} (Low force) Non-shorting Shorting Non-shorting Shorting D3C-1210 D3C-2210 D3C-1220 D3C-2220 Ratings Specification Slide Material Silver plated Minimum applicable load (reference value) * * Rotary lever 2 Contact Specifications List of models Operating Force (OF) Switching timing Actuator 1 5 VDC 1 mA Please refer to "●Using Micro Loads" in "Precautions" for more information on the minimum applicable load. Characteristics Rated voltage Resistive load 30 VDC 0.1 A Note. The above rating values were applied under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% RH (3) Operating frequency: 30 operations/min Permissible operating speed Permissible operating frequency Mechanical Electrical Insulation resistance Vibration resistance *1 Shock resistance 50 mΩ max. Between terminals of the same polarity 250 VAC 50/60 Hz for 1 min Between current-carrying metal parts and ground 250 VAC 50/60 Hz for 1 min Malfunction Durability Malfunction *1 Durability *2 Degree of protection Ambient operating temperature Ambient operating humidity Weight 30 operations/min 100 MΩ min. (at 250 VDC with insulation tester) Contact resistance (initial value) Dielectric strength 1 mm to 500 mm/s 200 operations/min 10 to 55 Hz, 1.5 mm double amplitude 1,000 m/s2 {approx. 100G} max. 300 m/s2 {approx. 30G}max. 50,000 operations min. (30 operations/min) IEC IP00 -20 to +80°C (at ambient humidity 60% max.) (with no icing or condensation) 85% max. (for +5 to +35°C) Approx. 0.3g Note. The data given above are initial values. *1. The given values apply for Total Travel Position. Close or open circuit of the contact is 1 ms max. *2. For testing conditions, consult your OMRON sales representative. 1 D3C Ultra Subminiature Detection Switch Mounting Holes (Unit: mm) M1.6 Tap 4±0.1 5.7±0.1 1.6 dia. holes Dimensions (Unit: mm) and Operating Characteristics 3 C B A 5.6 4.2 1dia. holes 1.6+0.12 dia. 0 8.7 6.7 5.7±0.15 holes 1.6 R1 FP OP 6 4.7 Type Non-Shorting Operating Characteristics 4±0.15 4.6 max. Model Operating Force OF Max. Releasing Force RF Min. 1 0.8 2.54 2.54 4 8 0.3 0.9 Shorting D3C -1210 D3C -1220 1.28 N {130 gf} (0.98 N {100 gf}) 0.10 N {10 gf} (0.15 N {15 gf}) 0.39 N {40 gf} 1.28 N {130 gf} (0.29 N {30 gf}) (0.98 N {100 gf}) 0.03 N {3 gf} 0.10 N {10 gf} (0.05 N {5 gf}) (0.15 N) {15 gf} Free Position Operating Position 0 1.5-0.15 dia. 3.5 FP Max. OP1 OP2 Total Travel Position TTP D3C -2210 4.8 mm 3.5±0.3 mm 2.5±0.3 mm 1.3±0.4 mm D3C -2220 0.39 N {40 gf} (0.29 N {30 gf}) 0.03 N {3 gf} (0.05 N {5 gf}) 4.8 mm 3.4±0.3 mm 2.6±0.3 mm 1.3±0.4 mm 2.54 Switching timing 3-1dia. holes 2.54 4.2 Non-shorting Model FP OP1 OP2 TTP 2(NC) 2(NC) 1 1 3(NO) 3(NO) FP Shorting Model OP1 OP2 TTP 8 Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The values for operating characteristics apply for operation in the A direction (straight line), and the values in parentheses indicate those for operation in the B (rotary) direction for reference. Precautions ★Please refer to "Common Precautions" for correct use. Cautions ●Soldering ●Mounting Plate For soldering time, we recommend to solder within 3 s at a soldering iron temperature of under 350°C. Soldering at a temperature exceeding 350°C, soldering for more than 3 s, or repeated soldering will degrade the Switch characteristics. Make sure that flux and liquid surface of the solder does not flow over the edge of the board when soldering. Please complete soldering a t a temperature of 260°C within 5 s. It is also recommended that you apply flux Switch mounting surface guard to the mounting surface of the Switch. Use materials other than ABS or polycarbonate for the mounting plate. Since grease is used for the Switch, it may cause cracks if grease from the Switch comes in contact with such materials. Correct Use ●Mounting Use M1.6 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 4.9 to 9.8×10-2 N·m {0.5 to 1 kgf·cm}. ●Application of Operation Force to the Lever ●Using Micro Loads Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The N-level reference value applies for the minimum applicable load. This value indicates the malfunction reference level for the reliability level of 60% (λ60). (JIS C5003) The equation, λ60=0.5×10-6/operation indicates that the 1 estimated malfunction rate is less than 2,000,000 operations with a reliability level of 60%. Voltage (V) 㧰 D3C-1210, D3C-2210 D3C-1220, D3C-2220 30 100 mA 0.16 mA 24 Do not apply loads from any other directions other than operating direction of the lever as shown in the following figure. It may damage the Switch or cause malfunction. Operating range 12 5 1 mA 0 0.1 1 10 100 1,000 Current (mA) 2 D3C Ultra Subminiature Detection Switch 㧰 3 C • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. C099-E1-04 0812(0207)(O) 3
D3C2220 价格&库存

很抱歉,暂时无法提供与“D3C2220”相匹配的价格&库存,您可以联系我们找货

免费人工找货