0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D3SHB0L1

D3SHB0L1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Switch Detector N.C. SPST Long Lever J-Bend 0.001A 5VDC SMD T/R

  • 数据手册
  • 价格&库存
D3SHB0L1 数据手册
Surface Mount Detection Switch D3SH The smallest detection switch in the world. (OMRON’s data as of June 2006. ) ■ Ultra small size and ultra low profile contributing to down-sizing of sets devices. (3.0 × 3.4 × 0.9 mm (W × D × H)) ■ A unique mechanism enables high contact reliability and high precision operation. ■ Horizontal 2-way detection and long stroke for easy installation are available. ■ Meet a variety of applications by contact and lever variations. Ordering Information ■ Model Number Legend D3SH- □ □ □ ① ② ③ ① Contacts ② Boss of Positioning ③ Lever and Detection of Operation A: SPST-NO B: SPST-NC 0: without Boss 1: with Boss R : Right operating with standard lever L : Left operating with standard lever R1: Right operating with long lever L1 : Left operating with long lever ■ List of Modelsd Standard Lever Models Contact form SPSTNO Direction of Operation Right Left SPSTNC Right Left Note: Boss of Positioning Long Lever Models Model With Boss D3SH-A1R Without Boss D3SH-A0R With Boss D3SH-A1L Without Boss D3SH-A0L With Boss D3SH-B1R Without Boss D3SH-B0R With Boss D3SH-B1L Without Boss D3SH-B0L Minimum packing unit is 1,000 pcs./reel. Packing form Embossed tape packing (see note) Contact form SPSTNO Direction of Operation Right Boss of Positioning With Boss Without Boss Left SPSTNC Right Left Note: Model Packing form D3SH-A1R1 Embossed tape packing (see note) D3SH-A0R1 With Boss D3SH-A1L1 Without Boss D3SH-A0L1 With Boss D3SH-B1R1 Without Boss D3SH-B0R1 With Boss D3SH-B1L1 Without Boss D3SH-B0L1 Minimum packing unit is 1,000 pcs./reel. 1 D3SH D3SH Specifications ■ Contact Specifications Contact Specification Slide Minimum applicable load 15 μ A at 3 VDC ■ Characteristics Operating speed 1 mm to 300 mm/s Operating frequency Mechanical: 20 operations/min max. Electrical: 20 operations/min max. Insulation resistance 100 MΩ min. (at 100 VDC) Contact resistance (initial value) 3 Ω max. Dielectric strength 100 VAC for 1 min between terminals of same polarity Vibration resistance (see note 2) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance (see note 2) Destruction: 1000 m/s2 {approx. 100 G} max. Malfunction: 300 m/s2 {approx. 30 G} max. Durability(see note 3) Mechanical: 150,000 operations min. (20 operations/min.) Electrical: 100,000 operations min. (20 operations/min.) Ambient operating temperature -25 ℃ to 85 ℃ (at ambient humidity of 60 % max.) (with no icing or condensation) Ambient operating humidity 85 % max.(for 5 ℃ to 35 ℃ ) Weight Approx. 0.02 g Note: 1. The data given above are initial values. 2. The values apply at the total travel position. Contact opening or closing time is within 1ms. 3. For testing conditions, consult your OMRON sales representative. ■ Ratings Note: ■ Rated voltage Resistive load 5 VDC 1 mA Contact form SPST-NO The ratings values apply under the following test conditions: 1. Ambient temperature : 20 ± 2 ℃ COM N.O COM N.O N.C COM N.C 2. Ambient humidity: 65 ± 5% 3. Operating frequency: 30 operations/min. SPST-NC COM Note: 2 The cover connects with COM terminal inside. D3SH D3SH Dimensions ■ Packaging Specifications Carrier tape Label (18) (1.8) Feed direction 12±0.30 Drawing direction Conforms to JEITA Package Qty 1,000 pcs/reel φ13 Standard package Qty 1,000 pcs/reel ■ Standards φ380±2 Reel Dimensions and Operating Characteristics Note: 1. All units are in millimeters unless otherwise indicated. 2. Unless otherwise specified, a tolerance of ± 0.15 mm applies to all dimensions. 3. The operating characteristics are for operation in the A direction ( ↓ ) and B direction ( → , ← ). Standard Lever Models Model D3SH- □□ R D3SH- □□ L OF max. 0.3 N {31 gf} FP OP TTP 5.4 ± 0.2 mm 5.0 ± 0.2 mm 3.8 ± 0.15 mm ■ Standard Lever Models Right operating - without Boss A D3SH- □ 0R (0.9) 1.1 0.68 2.3 (2.2) R0.2 B TTP 0.25 3.1 0.8 FP OP center of rotation 0.4 0.4 0.55 1.65 1.1 1.65 2.2 4.4 3 0.9±0.05 0.39 PCB mounting land Dimension (Reference) (View from switch top) 0.5 0.36 z ■ Standard Lever Models Left operating - without Boss D3SH- □ 0L A (0.9) (2.2) R0.2 0.68 1.1 2.3 B OP 0.25 TTP FP center of rotation 0.8 0.4 0.55 1.1 0.4 3.1 1.65 1.65 3 0.9±0.05 0.39 2.2 4.4 PCB mounting land Dimension (Reference) (View from switch top) 0.5 0.36 3 D3SH ■ D3SH Standard Lever Models Right operating - with Boss D3SH- □ 1R A (0.9) (2.2) R0.2 1.1 0.68 2.3 B +0.07 2-φ0.7  0 center of rotation 0.4 2±0.1 0.8 3.1 2.8±0.07 0.4 0.4 0.55 2.8 1.65 2±0.05 1.1 TTP 0.25 C0.15 FP OP φ0.6±0.05 1.65 2.2 4.4 3 0.9±0.05 0.39 PCB mounting hole and land dimensions (Reference) (View from switch top) 0.5 0.36 ■ Standard Lever Models Left operating - with Boss A D3SH- □ 1L (0.9) (2.2) R0.2 0.68 1.1 2.3 2-φ0.7 +0.05  0 B center of rotation TTP FP OP 0.4 φ0.6±0.05 C0.15 2±0.1 0.4 2.8 0.55 1.65 2±0.05 1.1 0.25 0.8 0.4 2.8±0.07 3.1 1.65 2.2 4.4 3 0.39 0.9±0.05 PCB mounting hole and land dimensions (Reference) (View from switch top) 0.5 0.36 Long Lever Models D3SH- □□ R1 D3SH- □□ L1 Model OF max. 0.24 N {24 gf} FP OP TTP 5.9 ± 0.3 mm 5.4 ± 0.3 mm 3.8 ± 0.2 mm ■ Long Lever Models Right operating - without Boss D3SH- □ 0R1 A (0.9) 1.1 0.68 (3.1) 3 R0.2 B OP FP center of rotation 3.1 0.8 0.4 1.65 0.9±0.05 0.4 0.55 1.1 TTP 0.25 1.65 2.2 4.4 3 0.39 0.5 0.36 4 PCB mounting land Dimension (Reference) (View from switch top) D3SH ■ D3SH Long Lever Models Left operating - without Boss D3SH- □ 0L1 A (3.1) (0.9) 0.68 1.1 R0.2 3 B FP OP center of rotation TTP 0.25 0.8 0.4 0.55 1.65 1.1 3.1 0.4 1.65 2.2 4.4 3 0.9±0.05 0.39 PCB mounting land Dimension (Reference) (View from switch top) 0.5 0.36 ■ Long Lever Models Right operating - with Boss D3SH- □ 1R1 A 1.1 (0.9) (3.1) 3 0.68 R0.2 B 2-φ0.7+0.05  0 TTP 0.25 2±0.1 C0.15 3.1 0.8 2.8±0.07 FP OP center of rotation 0.4 φ0.6±0.05 0.4 0.4 0.55 2±0.05 1.1 2.8 1.65 1.65 2.2 4.4 3 0.9±0.05 0.39 PCB mounting hole and land dimensions (Reference) (View from switch top) 0.5 0.36 ■ Long Lever Models Right operating - with Boss D3SH- □ 1L1 A 1.1 (3.1) (0.9) 3 R0.2 0.68 B 2-φ0.7 +0.05 0 center of rotation OP TTP FP 0.4 φ0.6±0.05 C0.15 2±0.1 0.8 0.4 2.8 0.55 1.65 2±0.05 1.1 0.25 3.1 2.8±0.07 1.65 0.4 2.2 4.4 3 0.9±0.05 0.39 PCB mounting hole and land dimensions (Reference) (View from switch top) 0.5 0.36 5 D3SH D3SH Precautions ■ Caution Electrical Ratings ■ Confirm the contact load in order to select an appropriate switch rating. Do not apply an excessive electrical load to the contacts, otherwise the contacts may weld, resulting in a short circuit or burning. Correct Use Mounting The cover has the same electrical potential as the COM terminal. Do not short-circuit the cover with a NO or NC terminal when mounting the cover. Terminal Connection Do not use flow soldering or hand soldering to solder terminals. Conduct reflow soldering within the range shown in the terminal temperature profile below. Some reflow soldering devices have extremely high peak values. Do a test in advance to confirm proper soldering conditions. Do not conduct reflow soldering more than twice. Also provide a time interval of at least five minutes between the first and second reflow soldering processes to allow the Switch to return to room temperature. Heating the Switch continuously (without an interval) may cause the edges of the Switch to melt and degrade the characteristics. When printing for a cream solder process, a 0.13-mm screen thickness is recommended. Be sure to provide local ventilation. cover Be careful of the following points. Incorrect handling may lead to insufficient actuator return, Switch damage, or reduced durability. •Set the operating body in line with the direction of the actuator movement, and make sure that the operating body is completely separate from the actuator when the Switch is in the free position (FP). When the actuator is operated from the crosswise direction of the Switch, make sure that the corner of the operating body has a minimum radius of R1. 255 ℃ MAX 220℃ R1 min 150℃ Operating body Preheating time: 60 to 120 s Heating time: 40 s max. Printed Circuit Boards Special attention must be paid to the handling of printed circuit boards after a Switch has been mounted onto them. Airborne PCB particles may penetrate the interior of the Switch when printed circuit boards are separated by cutting. Also, do not stack printed circuit boards that have Switches mounted on them. Product Specification Details This document provides only a partial list of specifications. It is recommended that you request complete drawings and specifications prior to purchasing or using the product. •Set the Switch stroke to 70% to 100% of the overtravel (the difference between the operating position and the total travel position). •Do not subject the Switch to operations that involve strong impact. •Do not use the Switch as a stopper. •Do not apply excessive loads to the cover or operate the actuator from a direction other than a specified operating direction. •Do not use an adhesive to secure the Switch. A lubricant is used in the Switch. Some of the lubricant may seep out because the Switch does not have an airtight construction. Consider this possibility with respect to the usage conditions when designing or using the Switch. Application Environment Do not use the Switch in locations that are subject to toxic gas, silicon, excessive dust, excessive dirt, high temperatures, high humidity, sudden temperature changes, water splashes, or oil splashes. Otherwise, damage resulting by faulty contact of the Switch contacts, corrosion, or other causes, or other functional faults may occur. Insulation and Wiring Be sure that the installation conditions provide a sufficient insulation distance between Switch terminals and other metal parts, lands, etc. Cleaning The Switch does not have an airtight construction, and it must not be cleaned with cleaning fluids. Malfunctions may occur if the cleaning fluid penetrates the interior of the Switch together with flux or foreign matter from the surface of the PCB. Confirmation with Actual Equipment Be sure to confirm the quality of the product under the load and environmental conditions that will be used during actual applications. 6 D3SH ■ D3SH RoHS Directive Compliance Models that are indicated as being RoHS compliant are free of the following six substances. Lead : 1,000 ppm max. Mercury : 1,000 ppm max. Cadmium : 100 ppm max. Hexavalent chromium : 1,000 ppm max. PBB : 1,000 ppm max. PBDE : 1,000 ppm max. 7 D3SH D3SH OMRON Switches for Integration in Machinery Miniature Basic Switches (V-size) V VX D3V-01 D2MV Subminiature Basic Switches (S-size) D3M SS SS-P D2S D2VW D2RW D2SW D2SW-P D2T D2A D2RV K D2MC Ultra Subminiature Switches (J-size) D2F J D2MQ D2JW D2FW-G Sealed Basic Switches Door Switches D3D D2D D2HW Miniature Detection Switches D3C D2X D3K Surface Mount Detection Switch D3SH ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. B112-E1-01 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Electronic Components Company Switch Division Detection Switch Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7096/Fax: (81)75-344-7188 UTL : http://www.omron.com/ecb/ 8 Printed in Japan 0609-1M (0609) (W)
D3SHB0L1 价格&库存

很抱歉,暂时无法提供与“D3SHB0L1”相匹配的价格&库存,您可以联系我们找货

免费人工找货