D41L-8P5-CFM12-910M

D41L-8P5-CFM12-910M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON INDUSTRIAL AUTOMATION - D41L-8P5-CFM12-910M - SENSOR CORD, 12P M12 RCPT-FREE END, 10M

  • 数据手册
  • 价格&库存
D41L-8P5-CFM12-910M 数据手册
High-Coded Guard Lock Safety Door Switch D41L Ideal for harsh environments and hygienic applications • Minimizes defeat possibilities to prevent bypassing • Hygienic design with smooth surfaces and no key-hole prevents water, food and dust accumulation • ECOLAB-certified detergent resistant for quick cleaning • Complies with ISO 14119 (Type 4/High Coded), ISO 13849-1 (PLe) * The actuator is sold separately. Refer to Safety Precautions on page18 For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Identical mounting for left and right hinged doors Features ±2.0 mm ±3.5 mm Large actuator tolerances • Actuator tolerance in longitudinal direction ± 3.5 mm, lateral direction ± 2.0 mm Easy latching force adjustment • The latching force can be increased from 25 N to 50 N simply by turning the star handle 180°. • Position I: approx. 25 N, Position II: approx. 50 N User-friendly troubleshooting • LED displays simplify troubleshooting • LED red: Fault LED yellow: Status LED green: Power For actuator coding purposes, EN ISO 14119 also introduces a coding level classification that is applicable independently of the technology used. A high-coded safety switch is defined as one where a sensor is paired with a high-level coded actuator for which more than 1,000 variations are available. 1 D41L Model Number Structure Model Number Legend Safety Door Switch Sensor D41L (1)  D   (2) (3) (4) (5) (6) - N2 (7) (1) Model L: Guard Lock (2) Coding level / Teaching limitation 1: High (Individual coding) 2: High (Individual coding, No limitation) (3) OSSD configuration Y: Guard monitoring AND lock monitoring Z: Only guard monitoring (4) Diagnosis output D: With diagnosis output (5) Lock/release logic A: Power to unlock (Mechanical lock) G: Power to lock (Solenoid lock) (6) Release type Blank: Manual release E: Emergency exit (7) Connector N2: M12 Actuator D41L - A 1 (1) (2) (1) Model L: Guard Lock (2) Actuator type 2 D41L Ordering Information List of Models Sensors Classification (Lock and Release) Appearance Power to unlock (Mechanical lock) Power to lock (Solenoid lock) Coding level / Teaching limitation OSSD configuration Emergency exit Model High (Individual coding) Only guard monitoring - D41L-1ZDA-N2 High (Individual coding, No limitation) Only guard monitoring - D41L-2ZDA-N2 High (Individual coding) Guard monitoring AND lock monitoring - D41L-1YDA-N2 High (Individual coding, No limitation) Guard monitoring AND lock monitoring - D41L-2YDA-N2 High (Individual coding, No limitation) Guard monitoring AND lock monitoring Emergency exit High (Individual coding) Only guard monitoring - D41L-1ZDG-N2 High (Individual coding, No limitation) Only guard monitoring - D41L-2ZDG-N2 High (Individual coding) Guard monitoring AND lock monitoring - D41L-1YDG-N2 High (Individual coding, No limitation) Guard monitoring AND lock monitoring - D41L-2YDG-N2 High (Individual coding, No limitation) Only guard monitoring Emergency exit D41L-2ZDGE-N2 D41L-2YDAE-N2 Actuator (Sold separately) Appearance Name Actuator Features Model D41L-A1 3 different directions of actuation Accessory (Sold separately) Connecting cables Appearance Name Connecting cables with Connector M12 Specifications Connecting cables with Connector (M12) (female), 8-pole – 8 x 0.25mm2, straight, IP69 Cable length Model 5m D41L-8P5-CFM12-905M 10 m D41L-8P5-CFM12-910M Mounting Appearance Name Application Model Mounting plate For Sensor D41L-MP Mounting set For Actuator D41L-MS 3 D41L Standards Certification EU Declaration of Conformity • • • • Machinery Directive RE Directive RoHS Directive WEEE Directive Dispose in accordance with applicable regulations. Standards • • • • • EN ISO 13849-1: PL e Category 4 EN 60947-5-3 IEC 61508 EN 300 330 EN ISO 14119 UL Certification • UL508 • CAN/CSA C22.2 No.14 Regions where D41L can be used The product can be used in Japan, the United States of America, Canada, EU member states, the United Kingdom, and People's Republic of China. The use in other countries may conflict with radio laws of the countries. 4 D41L Ratings and Specifications Model D41L Technical Detection method RFID Frequency band 125 kHz Transmitter output -6 dBm max. Interlock type (ISO 14119) Type 4 Coded level (ISO 14119) D41L-1: High (individual coding) D41L-2: High (individual coding, No limitation) Actuator D41L-A1 Response time (ON to OFF) 100 ms max. Response time (input) 1.5 ms max. Risk time 200 ms max. Startup time 5 s max. Typical operating distance (Sn) (IEC 60947-5-3) 2 mm Assured operating distance (Sao) (IEC 60947-5-3) 1 mm Assured switch-off distance (Sar) 20 mm Electrical Supply voltage (Ue) 24 VDC (-15%/+10%) (stabilized PELV-power supply) Current consumption (Io) < 0.1 A Overvoltage category III Pollution degree 3 Operating current device with magnet switched on Average:
D41L-8P5-CFM12-910M 价格&库存

很抱歉,暂时无法提供与“D41L-8P5-CFM12-910M”相匹配的价格&库存,您可以联系我们找货

免费人工找货
D41L-8P5-CFM12-910M
  •  国内价格 香港价格
  • 1+996.670421+128.66180
  • 5+930.231565+120.08510
  • 10+863.7927010+111.50840

库存:0

D41L8P5CFM12910M
    •  国内价格
    • 1+454.84200
    • 30+432.86400

    库存:0