D4BL-4CRA-NPT

D4BL-4CRA-NPT

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    D4BL-4CRA-NPT

  • 数据手册
  • 价格&库存
D4BL-4CRA-NPT 数据手册
Guard Lock Safety-door Switch D4BL C39I-E-02 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia Note: Contact your sales representative for details on models with safety standard certification. • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is achieved using a mechanism where the lock is only released when voltage is applied to the solenoid. • Conforms to EN (TÜV) standards corresponding to the CE marking. • Certified by UL, CSA and CCC standards. • The Switch contact is opened by a direct opening mechanism (NC contacts only) when the protective cover is opened. Direct opening mechanism that is EN-certified is indicated by on the Switch. • Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure. • Tough aluminum die-cast body incorporating a switch box with degree of protection satisfying IP67, UL, and CSA TYPE6P, 13. • Equipped with a horizontal and vertical conduit opening. • Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a swinging door are available. • The mounting direction of the head can be changed Be sure to read the “Safety Precautions” on page 13. to allow the Operation Key to be inserted from four directions. • Conforms to ISO 14119. Model Number Structure Model Number Legend Switch D4BL - 1 2 3 4 - 5 1. Conduit Size (2-conduit) 1: PG13.5 2: G1/2 4: M20 2. Built-in Switch (with Safety Switch and Lock Monitor Switch Contacts) C: 1NC/1NO (slow-action) + 1NC (slow-action) D: 2NC (slow-action) + 1NC (slow-action) 3. Head Mounting Direction R: Four mounting directions possible (right-side mounting at shipping) 4. Door Lock and Release (Auxiliary Release Key is Incorporated by All Models) A: Mechanical lock/24 VDC solenoid release G: 24 VDC Solenoid lock/Mechanical release 5. Indicator Blank: Without indicator A: 10 to 115 VAC or VDC driving (with orange and green LED indicator unit) Operation Key D4BL - K 1 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 1 D4BL Switch Operation Key D4BL -2GRD-AT 1 2 3 4 D4BL - K 5 1. Conduit Size (2-conduit) 2: G1/2 2. Built-in Switch G: 2NC (slow-action) + 2NC (slow-action) 3. Head Mounting Direction R: Four mounting directions possible (right-side mounting at shipping) 4. Door Lock and Release D: Mechanical lock/24 VDC solenoid release 5. Indicator lamp A: Equipped with an orange/green LED display unit 1 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) Ordering Information List of Models Switches (Operation Keys are sold separately.) : Models with certified direct opening contacts. Consult with your OMRON representative when ordering any models that are not listed in this table. Lock method Mechanical lock Solenoid lock Without indicator 1NC/1NO+ 1NC (Slow-action) With LED indicator 1NC/1NO+ 1NC (Slow-action) Without indicator 2NC+ 1NC (Slow-action) With LED indicator 2NC+ 1NC (Slow-action) D4BL-1CRA D4BL-1CRA-A D4BL-1DRA D4BL-1DRA-A D4BL-2CRA D4BL-2CRA-A D4BL-2DRA D4BL-2DRA-A M20 D4BL-4CRA D4BL-4CRA-A D4BL-4DRA D4BL-4DRA-A Pg 13.5 D4BL-1CRG D4BL-1CRG-A D4BL-1DRG D4BL-1DRG-A D4BL-2CRG D4BL-2CRG-A D4BL-2DRG D4BL-2DRG-A D4BL-4CRG D4BL-4CRG-A D4BL-4DRG D4BL-4DRG-A Conduit size Voltage for solenoid PG13.5 G1/2 G1/2 M20 24 VDC 24 VDC Operation Keys Mounting type Model Horizontal mounting D4BL-K1 Vertical mounting D4BL-K2 Adjustable mounting D4BL-K3 2 D4BL Specifications Standards and EC Directives Conforms to the following EC Directives: Certified Standards • Machinery Directive • Low Voltage Directive • EN ISO 14119 Certification body TÜV Rheinland Certified Standard Ratings Standard EN60947-5-1 (certified direct opening) GS-ET-19 UL UL508 CSA CSA C22.2, No.14 CQC (CCC) GB14048.5 File No. Consult your OMRON representative for details. E76675 LR45746 2003010305073836 TÜV (EN60947-5-1), CCC (GB14048.5) Standard model Indicator model AC-15 AC-15 Rated operating current (Ie) 3A 6A Rated operating voltage (Ue) 250 V 115 V Item Type Utilization category Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. UL/CSA (UL508, CSA C22.2 No. 14) A300 Rated voltage 120 VAC 240 VAC Carry current 10 A Current (A) Volt-amperes (VA) Make Break 60 6 30 3 Make Break 7,200 720 Note: The UL/CSA certified rating for products with indicators (-A) is 6 A/115 VAC. 3 D4BL Characteristics Degree of protection *1 Durability *2 IP67 (EN60947-5-1) Mechanical 1,000,000 operations min. Electrical 500,000 operations min. (10 A resistive load at 250 VAC) Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Holding force 700 N min. (GS-ET-19) Contact resistance 50 mΩ max. Rated insulation voltage (Ui) 300 V (EN60947-5-1) Rated frequency 50/60 Hz Protection against electric shock Class I (with ground terminal) Pollution degree (operating environment) 3 (EN60947-5-1) Between terminals of same polarity Impulse withstand voltage (EN60947-5-1) Between terminals of different polarity 4 kV Between each terminal and ground Between solenoid and ground Insulation resistance 100 MΩ min. (at 500 VDC) Contact gap Vibration resistance Shock resistance 2.5 kV 2 × 2 mm min. Malfunction 10 to 55 Hz, 0.35 mm single amplitude Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. Conditional short-circuit current 100 A (EN60947-5-1) Conventional enclosed thermal current (Ithe) 10 A (EN60947-5-1) Ambient operating temperature –10 to 55°C (with no icing) Ambient operating humidity 95% max. Weight Approx. 800 g Note: The above values are initial values. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. *3. These figures are minimum requirements for safe operation. Solenoid Coil Characteristics Item Type 24 VDC mechanical lock models Rated operating voltage 24 VDC Current consumption +10% −15% 24 VDC solenoid lock models (100% ED) Approx. 300 mA Insulation class Class B (130°C or less) Indicator Characteristics Rated voltage 10 to 115 VAC/VDC Current leakage Approx. 1 mA Color (LED) Orange, green 4 D4BL Structure and Nomenclature Structure D4BL-@CR@-@ D4BL-@DR@-@ Operation Key Lock plate Operation Key Lock plate Auxiliary release key Lock monitor switch Solenoid Auxiliary release key Rotating drum Operation plunger Rotating drum Lock monitor switch Solenoid Operation plunger Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever Safety switch Safety switch Seal packing (NBR) Seal packing (NBR) Conduit opening Connection (Pull out terminal M3.5 horizontally) Conduit opening Conduit opening (Pull out (Pull out horizontally) vertically) Ground terminal M3.5 Connection terminal M3.5 Ground terminal M3.5 Conduit opening (Pull out vertically) The head can be changed to any of four directions. Contact Form (Diagrams Show State with Key Inserted and Lock Engaged) Model Contact (door open/ closed detection and lock monitor) Contact form Operating pattern Door open/ closed detection Lock monitor Remarks Lock position Door open/closed detection Lock monitor D4BL-@CR@-@ 1NC/1NO+1NC 31 32 11 Zb 12 Operation Key insertion completion position 24 23 ON Stroke The terminals 11-12 and 23-24 can be used as unlike poles. Extraction completion position Lock position Door open/closed detection Lock monitor D4BL-@DR@-@ 2NC+1NC 31 32 11 Zb 21 Note: The EN-certified direct opening mechanism is indicated by 12 22 ON Stroke Operation Key insertion completion position Extraction completion position Only NC contacts 11-12 have a certified direct opening mechanism. Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-12 and 21-22 can be used as unlike poles. on the Switch. Contact Form (D4BL-2GRD-AT) (Safety circuit side) (Monitor circuit side) 5 D4BL Dimensions and Operating Characteristics (Unit: mm) Switches D4BL-@@R@-@ Four, M3.5 head clamping screws (116.5) Red 31.5 17 10 74±0.1 6.8 100±0.1 112+1 0 (116.5) Four, M3.5 head clamping screws Model D4BL-@@R@-@ Key insertion force Key extraction force 19.61 N max. 19.61 N max. Movement before being locked 15 mm max. Total travel 23 mm min. 31.5 17 10 7 Indicator (Green: Solenoid ON). 37.5 Four, 5.3 dia. Mounting holes Four, M4 cover clamping screws Cover (123.5) 74±0.1 6.8 Conduit opening Operating Characteristics 46.3 Conduit opening D4BL-2GRD-AT 34.2 86+10 16 39.6 5.5 Indicators Red 37.5 Four, 5.3 dia. mounting holes Four, M4 cover clamping screws Cover (123.5) Conduit opening 7 Lock protection cap 15 34.2 100±0.1 +1 1120 5.5 +1 0 86 16 39.6 42.6 Indictor Conduit opening (Orange: Switch OFF) Conduit opening Operating Characteristics Model D4BL-2GRD-AT Key insertion force Key extraction force 19.61 N max. 19.61 N max. Movement before being locked 15 mm max. Total travel 23 mm min. Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application. 6 D4BL Operation Keys D4BL-K1 D4BL-K3 Red 78.7 40.7 20 12 Red Long mounting hole 7.3 15 25.8 15.6 5.3 36 5.3 Two, 2.65R 2.6 Red 7.5 20 11.8 5.6 4 dia. 4 D4BL-K2 12 40 20 18° 53.7 Red 26 13 25.8 15.6 5.3 x 7.3 long mounting hole 40 15.6 18° (80.7) 40 30 52.4 36 11.8 30 36 5.3 11.9 7.5 20 11.8 5.3 dia. 2.6 19.5 5.6 (37.8) 4 dia. 17.5 34.6 M4 Allen-head bolt 5.6 4 dia. 2.6 7 D4BL With Operation Key Inserted D4BL + D4BL-K2 D4BL + D4BL-K1 D4BL + D4BL-K3 Red Red 53.5 min. 57 max. (41) (12) Horizontal direction Operation Key insertion radius R ≥ 1200 54.5 min. 58 max. (20±0.15) (41) Horizontal direction Operation Key insertion radius R ≥ 250 Horizontal direction Operation Key insertion radius R ≥ 1200 (13) Red 81.5 min. 85 max. (41) (40) (40±0.15) (30±0.15) Vertical direction Operation Key insertion radius R ≥ 1000 Vertical direction Operation Key insertion radius R ≥ 1000 Vertical direction Operation Key insertion radius R ≥ 1000 54.5 min. 58 max. 53.5 min. 57 max. (20±0.15) (41) 81.5 min. 85 max. (41) (41) (35) (35) (35) Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. In the above diagrams, the Operation Key is inserted from the front. 8 D4BL Indicator Unit Four terminal plates Two, 7 dia. (7) Two LED (16) 26.8 53.2 57.2 (16) 0.3 5.6 2 10.6 (12.6) (35) 26.2 (61.2) Connections Internal Circuit Diagram Indicator 10 to 115 VAC/VDC Solenoid 24 VDC R ZD R E1 (+) LED E2 (−) Constant-current diode 9 D4BL Circuit Connection Example • Terminals 11 and 32 are connected internally and so connect terminals 12 and 31 for safety-circuit input. (GS-ET-19). • When using indicators, connect them to the auxiliary circuit side (monitor circuit) or in parallel between E1 and E2 as shown below. • Do not connect the indicators in parallel with the direct opening contact. If the indicators are broken, a short-circuit current may flow, causing equipment to malfunction. • The 24 VDC solenoid terminals have polarity. Confirm the polarity before wiring. 1. Orange: Lights when the solenoid turns ON. Green: Lights when the door opens. 2. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON. (Power supply side) (Power supply side) E1 (+) 12 11 23 24 32 31 Solenoid LED (orange) E2 (−) E1 (+) 12 11 23 24 32 31 LED (orange) LED (green) Auxiliary circuit (monitor circuit) Solenoid LED (green) Auxiliary circuit (monitor circuit) Safety circuit 3. Orange: Lights when the solenoid turns ON. Green: Lights when door closes. (Power supply side) Safety circuit 4. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON. (Power supply side) E1 (+) E1 (+) 12 11 21 22 32 31 Solenoid LED (orange) E2 (−) 12 11 21 22 32 31 Safety circuit Solenoid LED (orange) LED (green) Auxiliary circuit (monitor circuit) E2 (−) E2 (−) LED (green) Auxiliary circuit (monitor circuit) Safety circuit 10 D4BL Connection Example with OMRON’s G9SA Safety Relay Unit G9SA-321-T@ (24 VAC/VDC) + D4BL-@DRA-@ (Mechanical Lock Type) Circuit Diagram (Manual Reset) Lock release signal KM1 KM2 S2 S4 31 S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic Contactor M: 3-phase motor 32 11 21 12 22 PLC Guard S1 Feedback loop OPEN KM1 S3 KM2 Stop signal A1 A2 T11 TH T12 T31 T32 13 23 33 43 53 61 1 a K1 SA K2 K3 K3 a K1 b K2 K4 3 4 Off-Delay Timer K4 Control Circuit b 2 K1 5 K2 JP 1 2 3 4 5 6 6 PE T21 T23 T22 A 14 24 34 44 54 62 B KM1 KM2 Guard opens Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Lock release signal Operation instruction Motor controller KM1 S4 Guard can be opened Stop signal Reset switch S3 K1 and K2 (NC) K1 and K2 (NO) K3 and K4 (NC) KM2 M Note: This example circuit is for Category 3. K3 and K4 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) Operation instruction Motor rotation OFF-delay time 11 D4BL G9SA-301 (24 VAC/VDC) + D4BL-@DRG-@ (Solenoid Lock Type) Circuit Diagram (Auto-reset) Lock signal S2 31 32 11 21 12 22 S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch KM1 and KM2: Magnetic Contactor M: 3-phase motor S1 PLC 12 OPEN Feedback loop 11 KM1 KM2 Operation signal A1 A2 T11 TH T31 T12 T32 1 a K1 K1 K2 SA 13 23 33 41 3 4 K2 K1 b K2 a b Control Circuit 2 5 JP 1 2 3 4 5 6 6 PE T21 T23 T22 A B 14 24 34 42 KM1 KM2 Operation instruction Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Motor controller Guard opens KM1 KM2 Operation signal Lock signal K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) M Note: 1. This example circuit is for Category 4. 2. The lock can be released at any time. Therefore, do not use a model with a solenoid lock in applications where the operator may be exposed to danger when the guard opens. Use a model with a mechanical lock. 12 D4BL Safety Precautions ● Be sure to read the precautions for all D4BL models in the website at: http://www.ia.omron.com/. Precautions for Correct Use DANGER Injury may occasionally occur. Always check to make sure that the safety functions operate correctly before using the machine. The safety functions may not operate correctly because of wiring mistakes, setting mistakes, or Switch malfunction, causing some machines to continue operating in situations where they should be stopped. Injury may occasionally occur. If the machine is used with the release key in the UNLOCK position, the electromagnetic lock may not operate, causing some machines to continue operating in situations where they should be stopped. Be sure to put the release key in the LOCK position before using the machine. Also, check the condition of the lock and safety circuits. Injury may occasionally occur. When the electromagnetic lock function or Switch function is damaged, some machines may continue operating in situations where they should be stopped. Do not use the electromagnetic lock function of the Switch in place of a door lock. Always provide a lock separate from the Switch, attach a warning seal to prevent people from using excessive force to open the door when it is locked, or provide an indicator lamp to show the locked/unlocked status of the door. Appropriate Tightening Torque Loose screws may result in malfunction. Tighten the screws to the specified torques. No. Appropriate tightening torque Type 1 M3.5 terminal screw (including terminal screw) 2 Cover mounting screw 1.18 to 1.37 N·m 3 Head mounting screw 0.78 to 0.98 N·m 4 M5 body mounting screw * 4.90 to 5.88 N·m 5 Operation Key mounting screw 2.35 to 2.75 N·m 6 Connector 1.77 to 2.16 N·m 7 Cap screw 1.27 to 1.67 N·m 0.59 to 0.78 N·m * Use M5 screws. Apply a torque of 4.90 to 5.88 N·m for an Allen-head bolt. For a pan head screw, apply a torque of 2.35 to 2.75 N·m 5. Two, M5 Operation Key mounting screw 3. Four, M3.5 head-mounting screw Precautions for Safe Use • Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.) • Always attach the cover after completing wiring and before using the Switch. Also, do not turn ON the Switch with the cover open. Doing so may result in electric shock. • Make sure the Switch is mounted securely to prevent it from falling off. Otherwise injury may result. Stopper Installation Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration when mounting the Switch so that the Operation Key is within 0.5 to 5 mm of the set zone. Do not subject the Switch to a shock that exceeds the Switch's shock resistance of 1,000 m/s2. Incorrect Correct 2. Four, M4 cover-mounting screw 6. Conduit 7. Conduit cap 4. Four, M5 switch-mounting screw Auxiliary Release Key • The auxiliary release key is used to unlock the D4BL in case of emergency or in case the power supply to the D4BL fails. • Use the enclosed Release Key to change the lock from LOCK to UNLOCK so that the lock will be released and the door can be opened. (Applies only to mechanical locks. Release key is not provided with D4BL-2GRD-AT.) LOCK Stopper UNLOCK Auxiliary release key Switch Incorrect Gap Set zone Correct • Whenever the lock has been changed to UNLOCK, always return it to LOCK before using the Switch. • Do not use the auxiliary release key to start or stop machines. • Make sure that the auxiliary release key is kept with the person in charge. • To prevent the auxiliary release key from being handled carelessly by unauthorized people, seal the auxiliary release key with sealing wax and the provided seal cap to ensure IP67. • Before attaching the cover to the D4BL, make sure that the auxiliary release key position is set to LOCK. Solenoid Lock Models The solenoid lock locks the door only when power is supplied to the solenoid. Therefore, the door will be unlocked if the power supply to the solenoid stops. Therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating. 13 D4BL Switch and Operation Key Mounting Use four M5 screws and spring washers to mount the Switch and Operation Key, and tighten the screws to a suitable torque. To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and Operation Key from easily being removed. Mounting Dimensions Switch Mounting Dimensions Four, M5 Head Direction • The head can be mounted in four directions by loosening the four screws holding the head. To remove the head, turn the head at the surface mating with the Switch body by 45° as shown in figures (A) and (B) below. To change the direction of the head, make sure that the protruding part of the rotating lever engages with the groove of the plunger. Then turn the head clockwise or counterclockwise to the desired direction. At that time, make sure that the groove of the plunger is located under the rotating lever. If the direction of the head is not set when the plunger is rotated by 45°, the groove of the plunger presses the rotating lever. The head, plunger, or the built-in switch may be damaged as a result. Head Direction Changes 74±0.1 Left Front 100±0.1 (45°) Operation Key Mounting Holes D4BL-K1 Two, M5 (A) (45°) Back Right 20±0.1 D4BL-K2 (B) Head Bottom View Switch Top View Two, M5 40±0.1 D4BL-K3 Two, M5 30±0.1 Operation Key Rotation lever and protruding part Normal Positions of Rotating Lever and Plunger Switch body • The D4BL is provided with a shock-absorbing damper to protect the D4BL from damage that may result from dropping the D4BL during transportation. Be sure to remove the damper after mounting the D4BL. • The mounting tolerance of the Operation Key is ±0.3 mm vertically or horizontally. Be sure to mount the D4BL correctly without misalignment, otherwise the D4BL may soon break or wear out. • Observe the specified insertion radius for the Operation Key and insert it in a direction perpendicular to the key hole. Incorrect Operation plunger and groove mechanism Greater than ±0.3 Rotating lever (with protruding part) Plunger (with groove) Built-in switch • Be sure to check the mechanical lock and solenoid release functions when mounting the D4BL. • If the head direction is changed, recheck the tightening torque of each of screw. Make sure that no foreign materials will enter through the key hole on the head. Incorrect Greater than ±0.3 • Do not use the D4BS operation key. 14 D4BL Processing and Connecting Cable/ Conduit Cable Connection Example 1. Connect the wires to the terminals in the order shown below for wiring efficiency. • The following procedures are recommended for mounting and wiring the indicator unit securely. • To ensure IP67, use OMRON’s SC-@M and Nippon Flex’s ABS-08Pg13.5 and ABS-12 Pg13.5 Connectors. • Recommended cable: UL2464-type cable that is AWG20 to AWG18 (0.5 to 1.0 mm2) in size and has seven conductors • Connect the indicator unit after connecting the seven-conductor cable. Tighten each wired terminal clockwise to a torque of 0.59 to 0.78 N·m. Terminal no. Lp (mm) Lv (mm) E1 30±2 80±2 E2 35±2 75±2 31 45±2 60±2 12 55±2 50±2 23 (21) 65±2 45±2 24 (22) 70±2 35±2 90±2 50±2 a (mm) Twist the wire two or three times and make sure that no bare wire exists outside the terminal when tightening the terminal. 2. The insulation sheath of the seven-conductor cable must come into contact with the wall of the conduit mouth, side A or side B. 8±1 • Properly attach and securely tighten the provided conduit cap to the unused conduit opening to the suitable tightening torque when wiring the D4BL. Insulation sheath edge Others Do not touch the solenoid because the solenoid radiates heat while power is being supplied. 15 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Authorized Distributor: Automation Control Systems • Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders Temperature & Process Controllers • Single and Multi-loop Controllers Sensors & Vision • Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors • Amplified Photomicrosensors • Measurement Sensors • Ultrasonic Sensors • Vision Sensors Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators • Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches C39I-E-02 05/15 Note: Specifications are subject to change. Printed on recycled paper. © 2015 Omron Electronics LLC Printed in U.S.A.
D4BL-4CRA-NPT 价格&库存

很抱歉,暂时无法提供与“D4BL-4CRA-NPT”相匹配的价格&库存,您可以联系我们找货

免费人工找货