D4D-R
Manual Reset Limit Switch
Pull Reset Limit Switch
H Each model features a positive opening
H
H
H
H
mechanism (NC contacts only) and is
equipped with a lockable head
Conforms to EN standards (positive
on the
opening mechanism is shown by
Switch)
Positive opening mechanism
and double
approved by TÜV and BIA
insulation
Operates between --30°C and 70°C
Conforms to these standards and
EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
Eu
EN1088
H Approved Standards
Slow-Action Models
Agency
Standard
File No.
TÜV Rheinland
EN60947-5-1
EN81, EN115
R9451184
UL (see note 1)
UL508
CSA C22.2 No.14
E76675
BIA (see note 2)
GS-ET-15
1-conduit: 9505895
2-conduit: 9509914
SUVA (see note 2)
SUVA
1-conduit: 6013Z
2-conduit: 6012Z
(Positive opening:
approved)
Note: 1. CSA C22.2 No. 14 compliance was verified and
).
approved by UL (Marked with
2. Except for adjustable roller lever models.
2
D4D-R
Ordering Information
J MODEL NUMBER LEGEND
D4D-jjjjR
1
2
3
1.
Conduit
1: Pg13.5 (1-conduit, European type)
2: G1/2 (1-conduit, Japanese type)
3: 1/2-14NPT (1-conduit, North American type)
5: Pg13.5 (2-conduit, European type)
6: G1/2 (2-conduit, Japanese type)
2.
Built-in Switch
5: 1NC/1NO (Slow-action)
A: 2NC (Slow-action)
3.
Actuator
20: Roller lever
21: Adjustable roller lever
27: Adjustable roller lever (with rubber roller)
62: One-way roller arm lever (Horizontal)
72: One-way roller arm lever (Vertical)
31: Plunger
32: Roller plunger
J SWITCHES
Actuator
Roller lever
Conduit size/type
/ yp
1-conduit
2-conduit
Adjustable
j
roller
l
lever
(See Note 2)
1-conduit
2-conduit
Adjustable roller
lever (with rubber
roller)
(See Note 2)
1-conduit
2-conduit
Plunger
1-conduit
2-conduit
Roller plunger
p g
1-conduit
2-conduit
1NC/1NO (Slow-action)
2NC (Slow-action)
Positive
opening
(See Note 1)
Positive
opening
(see Note 1)
Part
number
Part
number
Pg13.5 (European)
D4D-1520R
D4D-1A20R
G1/2 (Japanese)
D4D-2520R
D4D-2A20R
1/2-14NPT (North American)
D4D-3520R
D4D-3A20R
Pg13.5 (European)
D4D-5520R
D4D-5A20R
G1/2 (Japanese)
D4D-6520R
D4D-6A20R
Pg13.5 (European)
D4D-1521R
D4D-1A21R
G1/2 (Japanese)
D4D-2521R
D4D-2A21R
1/2-14NPT (North American)
D4D-3521R
D4D-3A21R
Pg13.5 (European)
D4D-5521R
D4D-5A21R
G1/2 (Japanese)
D4D-6521R
D4D-6A21R
Pg13.5 (European)
D4D-1527R
D4D-1A27R
G1/2 (Japanese)
D4D-2527R
D4D-2A27R
1/2-14NPT (North American)
D4D-3527R
D4D-3A27R
Pg13.5 (European)
D4D-5527R
D4D-5A27R
G1/2 (Japanese)
D4D-6527R
D4D-6A27R
Pg13.5 (European)
D4D-1531R
D4D-1A31R
G1/2 (Japanese)
D4D-2531R
D4D-2A31R
1/2-14NPT (North American)
D4D-3531R
D4D-3A31R
Pg13.5 (European)
D4D-5531R
D4D-5A31R
G1/2 (Japanese)
D4D-6531R
D4D-6A31R
Pg13.5 (European)
D4D-1532R
D4D-1A32R
G1/2 (Japanese)
D4D-2532R
D4D-2A32R
1/2-14NPT (North American)
D4D-3532R
D4D-3A32R
Pg13.5 (European)
D4D-5532R
D4D-5A32R
G1/2 (Japanese)
D4D-6532R
D4D-6A32R
(This table continues on the next page.)
Note: 1. The Switches are marked with
indicating approval for the positive opening mechanism.
2. The adjustable roller lever models are approved by the EN ratings (TÜV Rheinland) but not by GS-ET-15 (BIA) and SUVA.
3
D4D-R
Ordering Information Table -- continued from previous page
Actuator
One-wayy roller
arm lever
l
(Horizontal)
Conduit size/type
/ yp
1-conduit
2-conduit
One-wayy roller
arm lever
l
(Vertical)
1-conduit
2-conduit
1NC/1NO (Slow-action)
2NC (Slow-action)
Positive
opening
(See Note 1)
Positive
opening
(See Note 1)
Part
number
Part
number
Pg13.5 (European)
D4D-1562R
D4D-1A62R
G1/2 (Japanese)
D4D-2562R
D4D-2A62R
1/2-14NPT (North American)
D4D-3562R
D4D-3A62R
Pg13.5 (European)
D4D-5562R
D4D-5A62R
G1/2 (Japanese)
D4D-6562R
D4D-6A62R
Pg13.5 (European)
D4D-1572R
D4D-1A72R
G1/2 (Japanese)
D4D-2572R
D4D-2A72R
1/2-14NPT (North American)
D4D-3572R
D4D-3A72R
Pg13.5 (European)
D4D-5572R
D4D-5A72R
G1/2 (Japanese)
D4D-6572R
D4D-6A72R
Note: 1. The Switches are marked with
indicating approval for the positive opening mechanism.
2. The adjustable roller lever models are approved by the EN ratings (TÜV Rheinland) but not by GS-ET-15 (BIA) and SUVA.
Specifications
J APPROVED STANDARD RATINGS
Applicable Standards
TÜV (EN60947-5-1)
Utilization category
AC-15
Rated operating current (Ie)
2A
Rated operating voltage (Ue)
400 V
UL (UL508/CSA C22.2 No.14)
A600
Rated voltage
Carryy current
Current
Volt-amperes
Make
Break
Make
Break
60 A
6A
7,200 VA
720 VA
240 VAC
30 A
3A
480 VAC
15 A
1.5 A
600 VAC
12 A
1.2 A
120 VAC
10 A
4
D4D-R
J CHARACTERISTICS
Degree of protection
IP65 (EN60947-5-1)
Life expectancy (see note)
Mechanical: 1,000,000 operations min.
Electrical: 150,000 operations min.
Operating speed
1 mm/s to 0.5 m/s
Contact gap
2 x 2 mm min.
Operating frequency
30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC) between terminals of the same polarity, and between each
terminal and non-current-carrying metal part
Contact resistance
25 mΩ max. (initial value)
Dielectric strength
Uimp 4 kV between terminals of the same polarity, between terminals of different polarity,
and between each terminal and non-current-carrying metal part (EN60947-5-1)
Rated insulation voltage (Ui)
400 V (EN60947-5-1)
Switching overvoltage
1,500 V max. (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current
(Ithe)
10 A (EN60947-5-1)
Protection against electric shock
Class II (double insulation)
Vibration resistance
Malfunction: 10 to 55 Hz, 0.75-mm single amplitude
Shock resistance
Destruction: 1,000 m/s2 min.
Malfunction: 300 m/s2 min.
Ambient temperature
Operating: --30°C to 70°C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 80 g (for D4D-1120R)
Note: Life expectancy values are calculated at an operating temperature of 5°C to 35°C and an operating humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating environments.
J OPERATING CHARACTERISTICS
1-Conduit Models
Part number
D4D-1520R
D4D-2520R
D4D-3520R
D4D-1A20R
D4D-2A20R
D4D-3A20R
D4D-1521R
D4D-2521R
D4D-3521R
D4D-1A21R
D4D-2A21R
D4D-3A21R
(See Note 1)
D4D-1527R
D4D-2527R
D4D-3527R
D4D-1A27R
D4D-2A27R
D4D-3A27R
(See Note 2)
D4D-1531R
D4D-2531R
D4D-3531R
D4D-1A31R
D4D-2A31R
D4D-3A31R
D4D-1532R
D4D-2532R
D4D-3532R
D4D-1A32R
D4D-2A32R
D4D-3A32R
D4D-1562R
D4D-2562R
D4D-3562R
D4D-1A62R
D4D-2A62R
D4D-3A62R
D4D-1572R
D4D-2572R
D4D-3572R
D4D-1A72R
D4D-2A72R
D4D-3A72R
LF max.
6.37 N
5.59 N
5.39 N
10.79 N
10.79 N
7.35 N
7.85 N
LT max.
55°
55°
55°
4.5 mm
4.5 mm
7 mm
7 mm
PT1 max.
(See Note 3)
18° to 27°
18° to 27°
18° to 27°
2 mm
2 mm
4 mm
4 mm
PT2
(See Note 4)
44°
44°
44°
2.9 mm
2.9 mm
5.2 mm
4.3 mm
OP
---
---
---
34±0.5 mm
44.4±0.8 mm
53±0.8 mm
27±0.8 mm
TT
(See Note 5)
70°
70°
70°
6 mm
6 mm
9 mm
9 mm
POF min.
(see note 6)
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
POT min.
(See Note 6)
50°
50°
50°
3.2 mm
3.2 mm
5.8 mm
4.8 mm
Note: 1.
2.
3.
4.
The operating characteristics of these Switches were measured with the roller lever set at 30 mm.
The operating characteristics of these Switches were measured with the roller lever set at 31 mm.
These PT1 values are possible when the NC contacts are OFF.
These PT2 values are possible when the NO contacts are ON (applicable to D4D-jR models with 1NC and 1NO contact
each).
5. Reference value.
6. POT (positive opening travel) and POF (positive opening force) are required values for positive opening.
5
D4D-R
2-Conduit Models
Part number
D4D-5520R
D4D-6520R
D4D-5A20R
D4D-6A20R
D4D-5521R
D4D-6521R
D4D-5A21R
D4D-6A21R
D4D-5527R
D4D-6527R
D4D-5A27R
D4D-6A27R
D4D-5531R
D4D-6531R
D4D-5A31R
D4D-6A31R
D4D-5532R
D4D-6532R
D4D-5A32R
D4D-6A32R
D4D-5562R
D4D-6562R
D4D-5A62R
D4D-6A62R
D4D-5572R
D4D-6572R
D4D-5A72R
D4D-6A72R
LF max.
6.37 N
5.59 N
5.39 N
10.79 N
10.79 N
7.35 N
7.85 N
LT max.
55°
55°
55°
4.5 mm
4.5 mm
7 mm
7 mm
PT1 max.
(See Note 3)
18° to 27°
18° to 27°
18° to 27°
2 mm
2 mm
4 mm
4 mm
PT2
(See Note 4)
44°
44°
44°
2.9 mm
2.9 mm
5.2 mm
4.3 mm
OP
---
---
---
34±0.5 mm
44.4±0.8 mm
53±0.8 mm
27±0.8 mm
TT
(See Note 5)
70°
70°
70°
6 mm
6 mm
9 mm
9 mm
POF min.
(See Note 6)
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
19.61 N
POT min.
(See Note 6)
50°
50°
50°
3.2 mm
3.2 mm
5.8 mm
4.8 mm
Note: 1.
2.
3.
4.
The operating characteristics of these Switches were measured with the roller lever set at 30 mm.
The operating characteristics of these Switches were measured with the roller lever set at 31 mm.
These PT1 values are possible when the NC contacts are OFF.
These PT2 values are possible when the NO contacts are ON (applicable to D4D-jR models with 1NC and 1NO contact
each).
5. Reference value.
6. POT (positive opening travel) and POF (positive opening force) are required values for positive opening.
Nomenclature
Head
With roller lever models, the direction of the switch head can
be adjusted to any of the four directions by loosening the
roller lever switch screws at the four corners of the head.
Safety-Oriented Lever Setting
Grooves which engage the lever every 90° are cut in the
operation indicator disk to prevent the lever from slipping
against the rotary shaft.
Reset Head
The direction of the reset head can be adjusted to any of
the four directions.
Built-in Switch
Has a positive opening mechanism separating the contacts when the contacts are welded.
Conduit
Wide switch variations.
Pg13.5:
1-conduit, 2-conduit models
G1/2:
1-conduit, 2-conduit models
1/2-14NPT: 1-conduit models
Cover
The cover, with a hinge on its lower part, can be opened by
removing the screw of the cover, which ensures ease of
maintenance and wiring.
Note: The D4D-jR uses NBR.
6
D4D-R
Operation
J CONTACT FORM
Model
Contact
D4D-j5jN
1NC/1NO
(slow-action)
Diagrams
Zb
11
12
Remarks
Only NC contact 11-12 has an
approved positive opening
mechanism.
11-12
23-24
23
24
Stroke
ON
D4D-jAjN
2NC
(slow-action)
Zb
11
12
NC contacts 11-12 and 21-22 have an
approved positive opening
mechanism.
11-12
21-22
21
Terminals 11-12 and 23-24 can be
used as unlike poles.
Stroke
22
ON
Terminals 11-12 and 21-22 can be
used as unlike poles.
Note: Terminals are numbered according to EN50013 and contacts are marked according to EN60947-5-1.
J POSITIVE OPENING MECHANISM
1NC/1NO Contact (Slow-Action)
2NC Contact (Slow-Action)
Fixed contact (NC)
Fixed contact (NC)
Contact spring
Movable contact
Contact spring
Movable contact
Plunger
Return spring
Fixed contact (NO)
Return spring
Plunger
Only the NC contacts have a positive
opening function.
Both NC contacts have a positive opening
function.
When metal deposition occurs, the contacts
are separated from each other by pushing in
the plunger.
When metal deposition occurs, the contacts
are separated from each other by pushing in
the plunger.
Conforms to EN60947-5-1 Positive Opening
Conforms to EN60947-5-1 Positive Opening
Note: The Switches are marked with “
” indicating approval for the positive opening mechanism.
7
D4D-R
Dimensions
Unit: mm
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The minimum number of screw threads is five when the Pg13.5 conduit is used and four when the G1/2 conduit is used.
J SWITCHES
1-Conduit Models
Roller Lever
D4D-1520R
D4D-2520R
D4D-3520R
D4D-1A20R
D4D-2A20R
D4D-3A20R
17.5 dia. x 6.8
resin roller
20.5 x 20.5
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
0
dia. holes
depth: 5
Adjustable Roller Lever
D4D-1521R
D4D-2521R
D4D-3521R
D4D-1A21R
D4D-2A21R
D4D-3A21R
17.5 dia. x 6.8
resin roller
R20 to 65
20.5 x 20.5
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
+0.15
Two. 4 0
depth: 5
dia. holes
Adjustable Roller Lever
(Rubber Roller Lever)
D4D-1527R
D4D-2527R
D4D-3527R
D4D-1A27R
D4D-2A27R
D4D-3A27R
50 dia. x 8
rubber roller
R31 to 65
20.5 x 20.5
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
8
Two. 4 +0.15
0
dia. holes
depth: 5
D4D-R
Plunger
20.5 x 20.5
D4D-1531R
D4D-2531R
D4D-3531R
D4D-1A31R
D4D-2A31R
D4D-3A31R
6 dia.
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
0
dia. holes
depth: 5
Roller Plunger
D4D-1532R
D4D-2532R
D4D-3532R
D4D-1A32R
D4D-2A32R
D4D-3A32R
9.5 dia. x 5
resin roller
20.5 x 20.5
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
One-way Roller Arm Lever
(Horizontal)
+0.15
Two. 4 0
depth: 5
dia. holes
12 dia. x 5
resin roller
D4D-1562R
D4D-2562R
D4D-3562R
D4D-1A62R
D4D-2A62R
D4D-3A62R
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
0
dia. holes
depth: 5
One-way Roller Arm Lever
(Vertical)
D4D-1572R
D4D-2572R
D4D-3572R
D4D-1A72R
D4D-2A72R
D4D-3A72R
12 dia. x 5
resin roller
14 dia.
R2.15±0.05
mounting holes
See Note 2,
referring to
the min. no.
of screw
threads.
9
+0.15
Two. 4 0
depth: 5
dia. holes
D4D-R
2-Conduit Models
Roller Lever
D4D-5520R
D4D-6520R
D4D-5A20R
D4D-6A20R
17.5 dia. x 6.8
resin roller
20.5 x 20.5
14 dia.
25 dia.
R2.15±0.05
mounting holes
Cap
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
0
dia. holes
depth: 5
Adjustable Roller Lever
D4D-5521R
D4D-6521R
D4D-5A21R
D4D-6A21R
17.5 dia. x 6.8
resin roller
R20 to 65
20.5 x 20.5
14 dia.
25 dia.
R2.15±0.05
mounting holes
Cap
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
0
dia. holes
depth: 5
Adjustable Roller Lever
(Rubber Roller Lever)
D4D-5527R
D4D-6527R
D4D-5A27R
D4D-6A27R
50 dia. x 8
rubber roller
R31 to 65
20.5 x 20.5
14 dia.
25 dia.
R2.15±0.05
mounting holes
Cap
See Note 2,
referring to
the min. no.
of screw
threads.
Two. 4 +0.15
dia. holes
0
depth: 5
10
D4D-R
J LEVERS
Refer to the following for the angles and positions of the dogs.
Roller Lever
D4D-jj20R
Adjustable Roller Lever
D4D-jj21R
10 min.
Adjustable Roller Lever
(Rubber Roller Lever)
D4D-jj27R
10 min.
Dog
Dog
45 min.
Dog
20 min.
10 min.
40 min.
25 min.
5 min.
15 min.
Roller Plunger
D4D-jj32R
Sealed Plunger
D4D-jj31R
Dog
Dog
Dog
Dog
20 min.
31 min.
41 min.
10 min.
One-Way Roller Arm Lever
(Horizontal)
D4D-jj62R
Dog
One-Way Roller Arm Lever
(Vertical)
D4D-jj72R
10 min.
20 min.
5.0 min.
5 min.
Dog
10 min.
30 max.
20 min.
Precautions
!
When the Limit Switch locks due to a fault in the system, be sure
to reset it manually before resupplying power after confirming the
safety of the system.
CAUTION
Do not use metal connectors or conduits with this Switch. Rigid
connectors and conduits may damage the Switch. A broken
conduit hole may cause an electrical shock hazard.
Be sure to connect a fuse with a breaking current 1.5 to 2 times
larger than the rated current to the Limit Switch in parallel, to
protect it from damage due to short-circuiting.
If the D4D-jR is applied to an emergency stop circuit or safety
circuit for prevention of injury, use the D4D-jR model that has
an NC contact equipped with a force-separation mechanism and
make sure that the D4D-jR operates in the positive mode. In
addition, secure the D4D-jR with screws or equivalent parts that
are tightened in a single direction so that the D4D-jR cannot be
easily removed. Then provide a protection cover for the D4D-jR
and post a warning label near the D4D-jR.
When using the Limit Switch for the EN ratings, use the gI or gG
10-A fuse.
Do not use the Limit Switch as a stopper.
Actuation of the Limit Switch over a long time may cause Switch
parts to deteriorate, and a releasing failure may result. Be sure to
check the condition of the Limit Switch regularly.
When using the Limit Switch as a safety component, be sure to
check the system design for both operational and circuit safety.
Ensure that the actuator is pushed into the lock position by, for
example, setting up a dog. Not doing so may result in the
actuator becoming unlocked and causing an accident.
11
D4D-R
Mounting Holes/Studs
J CORRECT USE
Standard 1-Conduit
Operating Environment
The Limit Switch is intended for indoor use only. Using the Limit
Switch outdoors may result in a malfunction.
Correct Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten
each screw to the proper tightening torque as shown below.
No.
Type
Torque
1
Terminal screw
0.59 to 0.78 N S m
2
Cover mounting
screw
0.78 to 0.88 N S m
3
Head mounting
screw
0.78 to 0.88 N S m
4
Lever mounting
screw
1.57 to 1.77 N S m
5
Switch mounting
screw (M4)
0.49 to 0.69 N S m
6
Connector
1.77 to 2.16 N S m
1.37 to 1.77 N S m (see note)
7
Cap screw
1.27 to 1.67 N S m
2-Conduit
4 --0.05
--0.15 dia. height, 4.8 max.
--0.05
4 --0.15 dia. height, 4.8 max.
Note: This applies to the 1/2-14NPT connector.
Changing the Head Direction
If the head direction has been changed, check the torque of each
screw and make sure that the screws are free of foreign
substances, and that each screw is tightened to the proper
torque.
Wiring
Do not connect the bare lead wires directly to the terminals,
but be sure to connect each of them by using an insulation
tube and M3.5 round solderless terminals and tighten each
terminal screw within the specified torque range.
The proper lead wire is 20 to 14 AWG (0.5 to 2.5 mm2) in
size.
To avoid an electrical shock, do not touch the terminals while
power is being supplied.
Mounting
Fasten the Switch with two M4 Allen-head bolts and washers.
Provide a stud with a diameter of 4-0.05/-0.15 and a height of 4.8
mm max. at two places as shown below so that the Switch is
firmly fixed at four points.
D dia.
dz dia.
D dia.
B:
L:
F:
ℓ:
Mounting hole
Mounting surface
Hole for stud insertion
4 --0.05
--0.15 dia. height, 4.8 max.
12
3.7
4.5
7.0
20.2
7.7
9.0 (mm)
dz dia.
D4D-R
Insert a cap screw provided with the D4D-jR into any unused
conduit opening of the D4D-jR and tighten the cap screw to a
torque of 1.27 to 1.67 N S m.
Perform wiring for the crimp terminals in the orientation shown
below, so that they do not rest on the case or the cover.
Correct
Recommended Connector
Incorrect
Terminal screw
Conduit size
Manufacturer
Model
Applicable
cable diameter
G1/2
OMRON
SC-6
7.5 to 9.0 mm
LAPP
(see note 1)
ST-PF1/2
5380-1002
6.0 to 12.0 mm
Ohm Denki
(see note 2)
OA-W1609
7.0 to 9.0 mm
Pg13.5
LAPP
(see note 1)
ST13.5
5301-5030
5.0 to 12.0 mm
1/2-14NPT
LAPP
(see note 1)
ST-NPT1/2
5301-6030
6.0 to 12.0 mm
Crimp-style terminal
Correct
Crimp-style terminal
Note: 1. LAPP is a German manufacturer.
2. Ohm Denki is a Japanese manufacturer.
Maintenance and Repairs
Incorrect
The user must not maintain or repair equipment incorporating any
D4D-jR model. Contact the manufacturer of the equipment for
any maintenance or repairs required.
Crimp-style terminal
Rubber Roller Lever Models
With rubber roller lever models, the rubber roller may turn white
with the passage of time, but this will not affect the quality of
operation.
Processing the Conduit Opening
Tighten the connector to a torque of 1.8 to 2.2 N S m (1.37 to
1.77 N S m if it is a 1/2-14NPT). Excessive tightening torque may
damage the casing. To satisfy IP65, apply sealing tape to the
connector conduit. The diameter of the cable must be suited to
the corresponding connector.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
OMRON ELECTRONICS LLC
OMRON CANADA, INC.
OMRON ON-LINE
One Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Toronto, Ontario M1B 5V8
847-843-7900
416-286-6465
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
For US technical support or other inquiries:
800-556-6766
Cat. No. GC SAFETY-2
2/03
Specifications subject to change without notice
13