0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D4GL-1GFG-A

D4GL-1GFG-A

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    D4GL-1GFG-A

  • 数据手册
  • 价格&库存
D4GL-1GFG-A 数据手册
Guard Lock Safety-door Switch/Slide key D4GL/D4GL-SK10-LK@ CSM_D4GL_D4GL-SK10-LK_DS_E_6_1 Vertically Mounting Guard Lock Safety-door Switch Ideal for Limited Installation Space • Selectable Operation Key insertion direction. • Slim safety-door switch with an electromagnetic lock or unlock mechanism . • Built-in switches with multiple-contact construction are available. • A key holding force of 1,000 N minimum. • Can be used for either standard loads or microloads. • Lineup includes models with a conduit size of M20. • Variety of Metallic Heads Available. Guard Lock Safety-door Switches Slide keys For the most recent information on models that have been certified for safety standards, refer to your OMRON website. • The D4GL Vertical Electromagnetic Lock and Safety-door Switches easily mount to a 40 × 40-mm aluminum frame section. • The Switches are made of resin so they are suitable for lightweight doors. Be sure to read the “Safety Precautions” on page 17 and the “Precautions for All Safety Door Switches”. Model Number Structure Model Number Legend Switch (Standard type) Switch (Metallic release key type) D4GL-@@@@-@@ D4GL-@@@@-@@-SJ 1 2 3 4 5 6 1. Conduit Size 1: Pg13.5 2: G1/2 4: M20 2. Built-in Switch (with Door Open/Closed Detection Switch and Lock Monitor Switch Contacts) A: 1NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts) B: 1NC/1NO (slow-action contacts) + 2NC (slow-action contacts) C: 2NC (slow-action contacts) + 1NC/1NO (slow-action contacts) D: 2NC (slow-action contacts) + 2NC (slow-action contacts) E: 2NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts) F: 2NC/1NO (slow-action contacts) + 2NC (slow-action contacts) G: 3NC (slow-action contacts) + 1NC/1NO (slow-action contacts) H: 3NC (slow-action contacts) + 2NC (slow-action contacts) 3. Head Mounting Direction and Material F: Four mounting directions possible (Front-side mounting at shipping)/plastic D: Four mounting directions possible (Front-side mounting at shipping)/metal 4. Door Lock and Release A: Mechanical lock/24 VDC solenoid release G: 24 VDC solenoid lock/mechanical release 5. Indicator A: 24 VDC (orange/green LED indicator) 6. Release Key Type Blank: Standard release key (resin) 4: Special release key (resin) (Note: Release keys are provided.) 1 2 3 4 5 6 1. Conduit Size 2: G1/2 (1-conduit) 4: M20 (1-conduit) 2. Built-in Switch A: 1NC/1NO + 1NC/1NO B: 1NC/1NO + 2NC C: 2NC + 1NC/1NO D: 2NC + 2NC E: 2NC/1NO + 1NC/1NO F: 2NC/1NO + 2NC G: 3NC + 1NC/1NO H: 3NC + 2NC 3. Head Material F: resin 4. Door Lock and Release A: Mechanical lock/24 VDC solenoid release G: 24 VDC solenoid lock/ mechanical release 5. Indicator A: 24 VDC (orange/green LED indicator) Note: The wiring specification is different from the wiring specification for the standard type. Please refer to the "Connection" section for details. 6. Release Key Type Blank: Standard release key (metal) Operation Key D4DS-K@ 1 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontal) 5: Adjustable mounting (horizontal/vertical) 1 D4GL/D4GL-SK10-LK@ Ordering Information List of Models Switches (Operation Keys are sold separately.) : Models with certified direct opening contacts. Consult with your OMRON representative when ordering any models that are not listed in this table. Head material Release key type Solenoid voltage/ indicator Lock and release types Contact configuration (door open/closed detection switch and lock monitor switch contacts) (slow-action) Certified direct opening NC contact Conduit size Pg13.5 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Mechanical lock Solenoid release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC Plastic Standard (resin) Solenoid: 24 VDC Orange/green LED: 24 VDC 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Solenoid lock Mechanical release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC Model D4GL-1AFA-A G1/2 D4GL-2AFA-A * M20 D4GL-4AFA-A Pg13.5 D4GL-1BFA-A G1/2 D4GL-2BFA-A M20 D4GL-4BFA-A Pg13.5 D4GL-1CFA-A G1/2 D4GL-2CFA-A M20 D4GL-4CFA-A Pg13.5 D4GL-1DFA-A G1/2 D4GL-2DFA-A * M20 D4GL-4DFA-A Pg13.5 D4GL-1EFA-A G1/2 D4GL-2EFA-A M20 D4GL-4EFA-A Pg13.5 D4GL-1FFA-A G1/2 D4GL-2FFA-A * M20 D4GL-4FFA-A Pg13.5 D4GL-1GFA-A G1/2 D4GL-2GFA-A M20 D4GL-4GFA-A Pg13.5 D4GL-1HFA-A G1/2 D4GL-2HFA-A * M20 D4GL-4HFA-A Pg13.5 D4GL-1AFG-A G1/2 D4GL-2AFG-A * M20 D4GL-4AFG-A Pg13.5 D4GL-1BFG-A G1/2 D4GL-2BFG-A M20 D4GL-4BFG-A Pg13.5 D4GL-1CFG-A G1/2 D4GL-2CFG-A M20 D4GL-4CFG-A Pg13.5 D4GL-1DFG-A G1/2 D4GL-2DFG-A * M20 D4GL-4DFG-A Pg13.5 D4GL-1EFG-A G1/2 D4GL-2EFG-A M20 D4GL-4EFG-A Pg13.5 D4GL-1FFG-A G1/2 D4GL-2FFG-A * M20 D4GL-4FFG-A Pg13.5 D4GL-1GFG-A G1/2 D4GL-2GFG-A M20 D4GL-4GFG-A Pg13.5 D4GL-1HFG-A G1/2 D4GL-2HFG-A * M20 D4GL-4HFG-A * Models with Korean S-mark certification. 2 D4GL/D4GL-SK10-LK@ Head material Release key type Solenoid voltage/ indicator Lock and release types Contact configuration (door open/closed detection switch and lock monitor switch contacts) (slow-action) Certified direct opening NC contact 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Mechanical lock Solenoid release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO Plastic Special release key (resin) 3NC+2NC Solenoid: 24 VDC Orange/green LED: 24 VDC 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Solenoid lock Mechanical release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC Conduit size Model Pg13.5 D4GL-1AFA-A4 G1/2 D4GL-2AFA-A4 M20 D4GL-4AFA-A4 Pg13.5 D4GL-1BFA-A4 G1/2 D4GL-2BFA-A4 M20 D4GL-4BFA-A4 Pg13.5 D4GL-1CFA-A4 G1/2 D4GL-2CFA-A4 M20 D4GL-4CFA-A4 Pg13.5 D4GL-1DFA-A4 G1/2 D4GL-2DFA-A4 M20 D4GL-4DFA-A4 Pg13.5 D4GL-1EFA-A4 G1/2 D4GL-2EFA-A4 M20 D4GL-4EFA-A4 Pg13.5 D4GL-1FFA-A4 G1/2 D4GL-2FFA-A4 M20 D4GL-4FFA-A4 Pg13.5 D4GL-1GFA-A4 G1/2 D4GL-2GFA-A4 M20 D4GL-4GFA-A4 Pg13.5 D4GL-1HFA-A4 G1/2 D4GL-2HFA-A4 M20 D4GL-4HFA-A4 Pg13.5 D4GL-1AFG-A4 G1/2 D4GL-2AFG-A4 M20 D4GL-4AFG-A4 Pg13.5 D4GL-1BFG-A4 G1/2 D4GL-2BFG-A4 M20 D4GL-4BFG-A4 Pg13.5 D4GL-1CFG-A4 G1/2 D4GL-2CFG-A4 M20 D4GL-4CFG-A4 Pg13.5 D4GL-1DFG-A4 G1/2 D4GL-2DFG-A4 M20 D4GL-4DFG-A4 Pg13.5 D4GL-1EFG-A4 G1/2 D4GL-2EFG-A4 M20 D4GL-4EFG-A4 Pg13.5 D4GL-1FFG-A4 G1/2 D4GL-2FFG-A4 M20 D4GL-4FFG-A4 Pg13.5 D4GL-1GFG-A4 G1/2 D4GL-2GFG-A4 M20 D4GL-4GFG-A4 Pg13.5 D4GL-1HFG-A4 G1/2 D4GL-2HFG-A4 M20 D4GL-4HFG-A4 3 D4GL/D4GL-SK10-LK@ Head material Release key type Solenoid voltage/ indicator Lock and release types Contact configuration (door open/closed detection switch and lock monitor switch contacts) 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Mechanical lock Solenoid release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO Plastic Standard (metal) 3NC+2NC Solenoid: 24 VDC Orange/green LED: 24 VDC 1NC/1NO+1NC/1NO 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC Solenoid lock Mechanical release 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC Conduit size Model G1/2 D4GL-2AFA-A-SJ * M20 D4GL-4AFA-A-SJ * G1/2 D4GL-2BFA-A-SJ * M20 D4GL-4BFA-A-SJ * G1/2 D4GL-2CFA-A-SJ * M20 D4GL-4CFA-A-SJ * G1/2 D4GL-2DFA-A-SJ * M20 D4GL-4DFA-A-SJ * G1/2 D4GL-2EFA-A-SJ * M20 D4GL-4EFA-A-SJ * G1/2 D4GL-2FFA-A-SJ * M20 D4GL-4FFA-A-SJ * G1/2 D4GL-2GFA-A-SJ * M20 D4GL-4GFA-A-SJ * G1/2 D4GL-2HFA-A-SJ * M20 D4GL-4HFA-A-SJ * G1/2 D4GL-2AFG-A-SJ * M20 D4GL-4AFG-A-SJ * G1/2 D4GL-2BFG-A-SJ * M20 D4GL-4BFG-A-SJ * G1/2 D4GL-2CFG-A-SJ * M20 D4GL-4CFG-A-SJ * G1/2 D4GL-2DFG-A-SJ * M20 D4GL-4DFG-A-SJ * G1/2 D4GL-2EFG-A-SJ * M20 D4GL-4EFG-A-SJ * G1/2 D4GL-2FFG-A-SJ * M20 D4GL-4FFG-A-SJ * G1/2 D4GL-2GFG-A-SJ * M20 D4GL-4GFG-A-SJ * G1/2 D4GL-2HFG-A-SJ * M20 D4GL-4HFG-A-SJ * * These models will receive Korean S-mark certification. Operation Keys Type Model Horizontal mounting D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 4 D4GL/D4GL-SK10-LK@ Slide keys Appearance Specifications Contents Model Slide Key: 1 (not yet mounted) D4GL mounting plate: 1 Door Switch special mounting screws: 4 Weight: Approx. 0.6 kg D4DS-K1 (operation key): 1 Mechanical durability: D4DS-K1 special mounting screws: 2 D4GL-SK10-LK 20,000 operations min. Lockout keys: 2 Lockout key strap: 1 Caution labels (stickers): 2 sheets (English and Japanese) Weight:Approx.0.1kg Inner Lever:1 D4SL-SK10H* Slide Key: 1 (not yet mounted) D4GL mounting plate: 1 Door Switch special mounting screws: 4 Weight:Approx.0.7kg D4DS-K1 (operation key): 1 Mechanical durability: D4DS-K1 special mounting screws: 2 D4GL-SK10-LKH 20,000 operations min. Lockout keys: 2 Lockout key strap: 1 Caution labels (stickers): 2 sheets (English and Japanese) Applicable Door Switch D4GL - D4GL Note: 1. The Door Switch is not included. Select the Door Switch depending on the necessary number of contacts and the conduit size. The contents are provided as a total set, individual contents cannot be ordered separately. 2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly. * The inner lever for D4GL-SK10-LK/D4SL-NSK10-LK that can not be used for other products and applications. D4GL-SK10-LK + D4GL-SK10-LK = D4GL D4GL-SK10-LKH + D4GL-SK10-LKH = D4GL 5 D4GL/D4GL-SK10-LK@ Features The lockout key prevents workers from becoming trapped without using a padlock. Note: Using two-color LEDs enables confirming whether the door is open or closed and locked or unlocked. Example: D4GL-2DFA-A with mechanical lock and solenoid release Locked (power not Close door. supplied to solenoid) The slide handle is closed. The handle-shaped fixture makes it easy to use the Door Switch. Close door. Attach the supplied caution labels for display. Locked (power not supplied to solenoid) The slide handle is closed. Left door Lockout Key The slide handle can be pulled. Open door. The slide handle is open. Door Opening to the Left. Do not turn the key as in the figure above if the slide handle is closed. Open door. The slide handle is open. Open door. The slide handle is open. The slide handle does not move. When the slide handle is open, the lockout key can be pulled regardless of whether power is being supplied to the solenoid or not. The slide handle is secured at the position shown in the figure. A worker holding the lockout key will not be trapped locked inside the hazardous area by another person. If the lockout key is not mounted, the slide handle will not move and the door will not close. 6 D4GL/D4GL-SK10-LK@ Specifications Standards and EC Directives Characteristics Conforms to the following EC Directives: • • • • • Degree of protection *1 Mechanical Machinery Directive Low Voltage Directive EN1088 EN60204-1 GS-ET-19 Certified Standards Standard type Certification body UL *1 CQC (CCC) Standard EN60947-5-1 (certified direct opening) UL508, CSA C22.2 No.14 GB14048.5 KOSHA *2 EN 60947-5-1 TÜV SÜD File No. Consult your OMRON representative for details. E76675 2003010305064264 Consult your OMRON representative for details. *1. Certification for CSA C22.2 No. 14 is authorized by the UL mark. *2. Only certain models have been certified. Metallic release key type Certification body Standard EN60947-5-1 (certified direct opening) TÜV SÜD KOSHA File No. Consult your OMRON representative for details. Consult your OMRON representative for details. EN 60947-5-1 Certified Standard Ratings TÜV (EN60947-5-1), CCC (GB14048.5) Utilization Item category Rated operating current (Ie) Rated operating voltage (Ue) AC-15 DC-13 0.75 A 240 V 0.27 A 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. UL/CSA (UL508, CSA C22.2 No. 14) C300 Rated voltage Carry current 120 VAC 240 VAC 2.5 A Current (A) Make Break 15 1.5 7.5 0.75 Volt-amperes (VA) Make Break Current (A) Make Break 0.55 0.55 0.27 0.27 Volt-amperes (VA) Make Break 1,800 180 Q300 Rated voltage Carry current 125 VAC 250 VAC 2.5 A 69 Solenoid Coil Characteristics Item Type Rated operating voltage (100% ED) Current consumption Insulation 24 VDC 24 VDC ±10% Approx. 200 mA Class B (130°C max.) Indicator Characteristics Item Rated voltage Current leakage Color (LED) Type LED 24 VDC Approx. 3 mA Orange/Green 69 IP67 (EN60947-5-1) 1,000,000 operations min. 500,000 operations min. (4 mA resistive load at 24 VDC) Durability *2 150,000 operations min. (1 A Electrical resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24 VDC, 2 circuits) *3 Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *4 60 N min. (EN60947-5-1) Direct opening travel *4 10 mm min. (EN60947-5-1) Holding force *5 1,000 N min. Contact resistance 100 mΩ max. 4 mA resistive load at 24 VDC (NMinimum applicable load *6 level reference value) Rated insulation voltage (Ui) 300 V (EN60947-5-1) Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation) Pollution degree (operating 3 (EN60947-5-1) environment) Between terminals of 2.5 kV same polarity Between 4 kV terminals of different polarity Impulse Between withstand solenoid and voltage 0.8 kV (EN60947-5- non-current carrying 1) metallic parts Between other terminals and non-current 4 kV carrying metallic parts Insulation resistance 100 MΩ min. (at 500 VDC) Contact gap 2 × 2 mm min. 10 to 55 Hz, 0.75 mm single Vibration Malfunction amplitude resistance Destruction 1,000 m/s2 min. Shock resistance Malfunction 300 m/s2 min. Conditional short-circuit 100 A (EN60947-5-1) current Conventional free air thermal 2.5 A (EN60947-5-1) current (Ith) Ambient operations temperature −10 to 55°C (with no icing) Ambient operations humidity 95% max. Weight Approx. 400 g (D4GL-1AFA-A) Note: 1. The above values are initial values. 2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4GL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 1 A, 125 VAC load through more than 2 circuits. *4. These figures are minimum requirements for safe operation. *5. This figure is based on the GS-ET-19 evaluation method. *6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. 7 D4GL/D4GL-SK10-LK@ Connections Internal Circuit Diagram Indicator Connection Example for D4GL-1HFA-A 51 Solenoid 24V DC E1 (+) D4GL-@@@@-@@ D LED (Green) (+) 12 41 42 11 Safety circuit 52 21 Auxiliary circuit 22 D Auxiliary circuit LED (Orange) (+) E2 (−) LED LED (Green) (Orange) 31 32 O1 (Green) 5 to 24V DC CRD CRD ZD ZD COM (−) D4GL-@@@@-@@-SJ D LED (Green) (+) LED (Green) LED (Green) E2 E1 O3 (Orange) Auxiliary circuit O2 (Black) Solenoid LED (Orange) • Direct opening contacts used as safety-circuit input are indicated with the mark. Terminals 11 and 12 and terminals 21 and 22 are direct opening contacts. • Connect the indicators in parallel to the auxiliary circuits or terminals E1 and E2. • Although the 3 lines are connected at the time of delivery, rewire them as necessary for the application. 5 to 24V DC CRD ZD LED (Green) (−) Indicator Terminal number Lead wire color Connected terminal number * Green indicator (+) 01 Green 31 Orange indicator (+) 03 Orange E1 Common (-) 02 Black E2 Indicator Terminal number Lead wire color Connected terminal number * Green indicator (+) 01 Green 31 D LED (Orange) (+) LED (Orange) 5 to 24V DC CRD ZD LED (Orange) (−) Circuit Connection Example • Terminals 12 and 41 are connected internally and so connect terminals 11 and 42 for safety-circuit input. (BIA GS-ET-19) • Connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety-circuit input (redundancy circuit for terminals 11 and 12 and terminals 41 and 42 above). Connect the terminals individually when using as auxiliary-circuit input (e.g., terminals 21 and 22 for safety-door open/closed monitoring and terminals 51 and 52 for monitoring the lock status). • In the following connection example, terminals 21 and 22 and terminals 51 and 52 are used as auxiliary-circuit input. In this case,the green indicator lights when the door is closed and the orange indicator lights when the solenoid turns ON. Green indicator (-) 04 White − Orange indicator (+) 03 Orange E1 Orange indicator (-) 05 Black E2 * The terminal number of green indicator will be different according to the contact configuration. D4GL-@@@@-@@ 2 “2” : A, B, E, or F =33 “2” : C or D =21 “2” : G or H =31 • If an indicator is connected in parallel to a direct opening contact, when the indicator breaks, a short-circuit current will be generated, possibly resulting in an installation malfunction. • Do not switch circuits for two or more standard loads at the same time. Doing so may adversely affect insulation performance. • DC solenoids have polarity. Confirm terminal polarity before wiring. 8 D4GL/D4GL-SK10-LK@ Operation Method Operation Principles Plunger return spring LOCK Lock spring UNLOCK Linking arm The lock plate and monitor switch are linked. Mechanical lock models Return spring OFF OFF ON When the door is closed, it is locked by the The solenoid is released only when the lock spring. The door will stay locked even lock is turned ON. if there is a power interruption. Plunger return spring Lock return spring LOCK UNLOCK Linking arm The lock plate and monitor switch are linked. Solenoid lock models Return spring OFF ON OFF If the solenoid is OFF, the door will not be locked when it is closed. This means that the door can be opened and closed easily when replacing workpieces or parts. The door is locked only when the solenoid is turned ON. This means that the door will be unlocked if there is a power interruption and so this model cannot be used in systems that would maintain a hazardous state (e.g., systems requiring toxic gases, high temperatures, or gears that would continue to turn due to inertia). Structure and Nomenclature Structure Operation key hole Indicator (green) Indicator (orange) Release key Terminal 42 Terminal 21 Terminal 11 Terminal 22 Terminal 31/33 Terminal 51/53 Terminal 32/34 Conduit opening Terminal 52/54 Conduit opening Terminal E2 (−) Terminal E1 (+) Cover Note: Terminal numbers vary with the model. Confirm terminal numbers by referring to the cover on the back of the Switch. 9 D4GL/D4GL-SK10-LK@ Contact Form Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per BIA GS-ET-19). Model Contact (door open/closed detection and lock monitor) Contact form Door open/ closed detection Operating pattern Lock monitor Remarks Lock position D4GL-@AF@-@ 1NC/1NO + 1NC/1NO Door open/ closed detection Zb 11 12 Lock monitor 41 42 33 53 54 Zb 11-42 33-34 53-54 ON Stroke 34 Operation Key insertion completion position Extraction completion position Lock position D4GL-@BF@-@ 1NC/1NO + 2NC Door open/ closed detection Zb 11 12 Lock monitor 41 42 33 51 52 Zb 11-42 33-34 51-52 ON Operation Key insertion completion position Extraction completion position Lock position D4GL-@CF@-@ 2NC + 1NC/1NO Door open/ closed detection Zb 11 12 41 42 21 53 54 22 Lock monitor Zb 11-42 21-22 53-54 ON Stroke Operation Key insertion completion position Extraction completion position Lock position D4GL-@DF@-@ 2NC + 2NC Door open/ closed detection Zb 11 12 41 42 21 51 52 22 Lock monitor Zb 11-42 21-22 51-52 ON Stroke Operation Key insertion completion position Extraction completion position Lock position D4GL-@EF@-@ 2NC/1NO + 1NC/1NO Door open/ closed detection Zb 11 12 Lock monitor 41 42 21 22 53 54 33 34 Zb 11-42 21-22 33-34 53-54 ON Stroke Operation Key insertion completion position Extraction completion position Lock position D4GL-@FF@-@ 2NC/1NO + 2NC Door open/ closed detection Zb 11 12 41 Lock monitor 42 21 22 51 52 33 34 Zb 11-42 21-22 33-34 51-52 ON Stroke Operation Key insertion completion position Extraction completion position Lock position D4GL-@GF@-@ 3NC + 1NC/1NO Door open/ closed detection Zb 11 12 41 Lock monitor 42 21 22 53 54 31 32 Zb 11-42 21-22 31-32 53-54 ON Stroke Operation Key insertion completion position Extraction completion position Lock position D4GL-@HF@-@ 3NC + 2NC Door open/ closed detection Zb 11 12 41 Lock monitor 42 21 22 51 52 31 32 Zb 11-42 21-22 31-32 51-52 ON Stroke Operation Key insertion completion position The terminals 11-42, 33-34, and 53-54 can be used as unlike poles. Only NC contact 11-12, has a certified direct opening mechanism. The terminals 11-42, 33-34, and 51-52 can be used as unlike poles. Stroke 34 Only NC contact 11-12 has a certified direct opening mechanism. Extraction completion position Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-42, 21-22, and 53-54 can be used as unlike poles. Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-42, 21-22, and 51-52 can be used as unlike poles. Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-42, 21-22, 33-34, and 53-54 can be used as unlike poles. Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-42, 21-22, 33-34, and 51-52 can be used as unlike poles. Only NC contacts 11-12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals 11-42, 21-22, 31-32, and 53-54 can be used as unlike poles. Only NC contacts 11-12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals 11-42, 21-22, 31-32, and 51-52 can be used as unlike poles. 10 D4GL/D4GL-SK10-LK@ Dimensions (Unit: mm) Dimensions and Operating Characteristics Switches D4GL-@@@@-A4 15.3 15.3 D4GL-@@@@-A Four, head mounting screws Four, head mounting screws Head cap Head cap Pre-travel distance 34.4 15.3 23.5 Four, 5.2-dia. holes 31.5 Four, 5.2-dia. holes Four, 9.2-dia. spot facings (depth: 10) Four, 9.2-dia. spot facings (depth: 10) Four, LED indicators Release key 84±0.2 Release key Cover mounting screw Cover mounting screw Two, cap screws (3) (3) Two, cap screws 30±0.2 (3) (21.5) (3) 30±0.2 43 (3) 23.5 43 23.5 (3) Conduit cap Model (18.5) (18.5) Conduit cap Operating characteristics (127.5) 148 (187) (127.5) 148 (187) 84±0.2 Four, LED indicators (21.5) 34.4 15.3 31.5 4.4 23.5 Pre-travel distance Operation Key 47.8 40 38 4.4 Operation Key 47 40 38 Operating characteristics D4GL-@@@@-A Key insertion force Key extraction force 15 N max. 40 N max. Pre-travel distance 10 mm max. Movement before being locked D4GL-@@@@-A4 Key insertion force Key extraction force 15 N max. 40 N max. Pre-travel distance Model 10 mm max. Movement before being locked 4 mm min. 4 mm min. Operation Keys D4DS-K1 17.5 D4DS-K3 28 14 13 30 28 15 Angle adjustment bolt 9 dia. 4 8 dia. 4.5 dia. 4.3 7 13 13 30 40 56 20° Four, 2.15R 7 Black 2 2 6.3 10.5 D4DS-K2 9 30 28 6 D4DS-K5 20.9 7 13 15 28 4 15 17 13.5 4.5 15 ° 8 30 41 2 4.3 Mounting Holes (Enlargement) 24.6 22.5 43 55 7 13 Four, 2.15R Black 18 ° 41 6.5 18 43 (7) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 11 D4GL/D4GL-SK10-LK@ Slide keys D4GL-SK10-LK (Open door.) 10 (Close door.) (98) 40×40 40×40 12.5 (40) Lockout key (8) (29) (314) (35) +10 15-5 (230) (112) (147) 107 (35) (28) (84) (71.8) 19.1 (20) 11.5 Shot bolt 17 (56.5) SLIDE SLIDE LOCK LOCK 50 SLIDE FREE SLIDE (64) (90.4) FREE Guide (76.2) Four, M6 mounting holes (32.5) Slide base D4DS-K1 Operation Key (350) 84.1 UN –LOCK UN –LOCK LOCK LOCK 4 30 4-M5 Cross-sectional view A-A 17 (22.7) A Guard Lock Safety-door A Switch D4GL 11.5 12.5 Two, M6 8 Switch base mounting holes D4GL-SK10-LKH (Open door.) (Close door.) 10 Aluminum frame 40×40 12.5 Lockout key (323) (40) (121) (147) (35) (239) (29) 107 84 37 (71.8) 19.1 (20) 11.5 (56.5) (115) 17 SLIDE SLIDE (78) LOCK LOCK 50 (64) (90.4) SLIDE FREE SLIDE FREE Guide Ø12 Ø40 (76.2) Inner Lever (32.5) Slide base D4DS-K1 (35) Operation Key Four, M6 mounting holes Shot bolt (350) 84.1 4 UN –LOCK UN –LOCK LOCK LOCK Cross-sectional 30 view A-A 4-M5 Guard Lock Safety-door Switch D4GL +10 15-5 17 Between slyde key unit (22.7) A A 11.5 12.5 Two, M6 8 Switch base mounting holes 12 D4GL/D4GL-SK10-LK@ With Operation Key Inserted D4GL + D4DS-K1 (with Front-inserted Operation Key) (38) D4GL + D4DS-K1 (with Top-inserted Operation Key) Horizontal insertion radius: R ≥ 200 (15) 51.5 min. 54 max. Key insertion position Center tolerance of key hole: ±1 Vertical insertion radius: R ≥ 200 (15) Center tolerance of key hole: ±1 Center tolerance of key hole: ±1 (15.2) 52.5 min. 55.0 max. Key insertion position (39) Center tolerance of key hole: ±1 Vertical insertion radius: R ≥ 200 (39) (31.7) Horizontal insertion radius: R ≥ 200 52.5 min. 55.0 max. Key insertion position D4GL + D4DS-K2 (with Top-inserted Operation Key) D4GL + D4DS-K2 (with Front-inserted Operation Key) (38) Horizontal insertion radius: R ≥ 200 (15) 47.5 min. 50 max. Key insertion position Center tolerance of key hole: ±1 Vertical insertion radius: R ≥ 200 Vertical insertion radius: R ≥ 200 (15) Center tolerance of key hole: ±1 48.5 min. 51.0 max. Key insertion position Center tolerance of key hole: ±1 (15.2) (6) (39) Center tolerance of key hole: ±1 (39) (31.7) Horizontal insertion radius: R ≥ 200 48.5 min. 51.0 max. Key insertion position 13 D4GL/D4GL-SK10-LK@ D4GL + D4DS-K3 D4GL + D4DS-K3 (with Top-inserted Operation Key) (with Front-inserted Operation Key) (38) Horizontal insertion radius: R ≥ 50 52.5 min. 55 max. (40) Key insertion position Center tolerance of key hole: ±1 Vertical insertion radius: R ≥ 200 Center tolerance of key hole: ±1 53.5 min. 56.0 max. Key insertion position D4GL + D4DS-K5 (with Top-inserted Operation Key) D4GL + D4DS-K5 (with Front-inserted Operation Key) (38) Center tolerance of key hole: ±1 (15.2) (40) (39) 53.5 min. 56.0 max. Key insertion position Vertical insertion radius: R ≥ 200 (39) (31.7) Center tolerance of key hole: ±1 Horizontal insertion radius: R ≥ 50 Horizontal insertion radius: R ≥ 50 59.5 min. 62 max. (41 or 43) Key insertion position Center tolerance of key hole: ±1 Vertical insertion radius: R ≥ 50 43±0.1 41±0.1 Center tolerance of key hole: ±1 60.4 min. 62.9 max. Key insertion position Horizontal insertion radius: R ≥ 50 Center tolerance of key hole: ±1 (15.2) (39) Center tolerance of key hole: ±1 (39) (31.7) Horizontal insertion radius: R ≥ 50 60.4 min. 62.9 max. Key insertion position 14 D4GL/D4GL-SK10-LK@ Application Examples PL/safety category Model Stop category Reset 1 Manual Guard Lock Safety-door Switch D4GL-@AFA-@ (Mechanical Lock Type) Safety Relay Unit G9SA-321-T@ (24 VAC/VDC) PLd/3 equivalent Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. ●Application Overview • • • • • The stop signal is sent to the motor controller. The power supply to the motor M is turned OFF after OFF-delay time. The lock release signal enables the guard to be opened. The S1 and S2 monitor the guard, and the power supply to the motor M is kept OFF while the guard is opened. The power supply to the motor M is turned ON again when the reset switch S3 is pressed while the guard is closed and locked. Lock release signal KM1 KM2 S2 S4 42 54 41 53 S1: 12 34 11 33 Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic Contactor M: 3-phase motor PLC PLC Guard 11 S1 OPEN Feedback loop KM1 12 KM2 S3 Stop signal A1 A2 T11 T31 T12 T32 13 1 TH a K1 K3 SA K4 a K1 b K2 K4 61 3 4 K3 K2 23 33 43 53 Off delay timer Control circuit b JP 2 K1 5 K2 1 2 3 4 5 6 6 PE T21 T23 T22 A B 14 24 34 44 54 KM1 62 KM2 Guard opens Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Lock release signal Operation instruction Motor controller KM1 S4 Guard can be opened KM2 Stop signal Reset switch S3 K1 and K2 (NC) K1 and K2 (NO) K3 and K4 (NC) K3 and K4 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) M Operation instruction Motor rotation OFF-delay time 15 D4GL/D4GL-SK10-LK@ PL/safety category PLe/4 equivalent Model Guard Lock Safety-door Switch D4GL-@AFG-@ (Solenoid Lock Type) Safety Relay Unit G9SA-301 (24 VAC/VDC) Stop category Reset 0 Auto Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. ●Application Overview • • • • The power supply to the motor M is turned OFF immediately by the stop signal. The guard can be opened by turning OFF the lock signal. The S1 and S2 monitor the guard, and the power supply to the motor M is kept OFF while the guard is opened. The power supply to the motor M is turned ON again when the guard is closed and locked. Lock signal S2 42 S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch KM1 and KM2: Magnetic Contactor M: 3-phase motor 54 41 53 12 34 11 33 PLC S1 PLC Guard 12 OPEN Feedback loop 11 KM1 KM2 Operation signal A1 A2 T11 T31 T12 T32 TH a 13 23 33 41 3 4 1 K1 K1 K2 SA K2 K1 b K2 a b Control Circuit 2 5 JP 1 2 3 4 5 6 6 PE T21 T23 T22 A B 14 24 34 42 KM1 KM2 Stop instruction Motor controller KM1 Timing Chart Limit switch S1 Guard opens KM2 Guard Lock Safety-door Switch S2 Operation signal M Lock signal K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) Note: The lock can be released at any time. Therefore, do not use a model with a solenoid lock in applications where the operator may be exposed to danger when the guard opens. Use a model with a mechanical lock. KM1 and KM2 (NO) 16 D4GL/D4GL-SK10-LK@ Safety Precautions Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/. Indication and Meaning for Safe Use DANGER Indicates an imminently hazardous situation which, if not avoided, is likely to result in serious injury or may result in death. Additionally there may be severe property damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, or undesirable effect on product performance. Wiring • Do not switch circuits for two or more standard loads (125 VAC, 1 A). Doing so may adversely affect insulation performance. • Always attach the cover after completing wiring and before using the Switch. Do not supply power when the cover is not attached. Electric shock may occur if the Switch is used without the cover attached. Installation • Make sure the Switch is mounted securely to prevent it from falling off. Otherwise injury may result. • Do not use a Switch as a stopper. • Be sure to install a stopper as shown in the following illustration when mounting the Switch and adjust the stopper so that the Operation Key is within the setting zone. (Setting zone: 0.5 to 3.0 mm) Stopper Set zone (0.5 to 3 mm) DANGER Injury may occasionally occur. Always check to make sure that the safety functions operate correctly before using the machine. The safety functions may not operate correctly because of wiring mistakes, setting mistakes, or Switch malfunction, causing some machines to continue operating in situations where they should be stopped. Injury may occasionally occur. If the machine is used with the release key in the UNLOCK position, the electromagnetic lock may not operate, causing some machines to continue operating in situations where they should be stopped. Be sure to put the release key in the LOCK position before using the machine. Also, check the condition of the lock and safety circuits. Injury may occasionally occur. Always ensure that the release key is set to "UNLOCK" or that the Operation Key is inserted before changing the direction of the head. Not doing so may damage the Switch, causing some machines to continue operating in situations where they should be stopped. Refer to “Release Key” on page 17. Injury may occasionally occur. When the electromagnetic lock function or Switch function is damaged, some machines may continue operating in situations where they should be stopped. Do not use the electromagnetic lock function of the Switch in place of a door lock. Always provide a lock separate from the Switch, attach a warning seal to prevent people from using excessive force to open the door when it is locked, or provide an indicator lamp to show the locked/unlocked status of the door. !CAUTION Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Operation Key • Do not subject the Switch to a shock that exceeds the Switch's shock resistance of 1,000 m/s2. Precautions for Correct Use The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Release Key • The release key is used to unlock the Switch in case of emergency or if the power supply to the Switch stops. • If the release key setting is changed from LOCK to UNLOCK, the lock will be released and the safety door can be opened (mechanical lock models only). • After setting the release key to UNLOCK to, for example, perform maintenance, be sure to return it to LOCK setting before resuming operation. • Do not use the release key to start or stop machines. • The auxiliary lock must be released only by authorized personnel. • Do not impose a force exceeding 0.5 N·m on the release key screws. The release key may be damaged and may not operate properly. • The release key is set in the unlock position at the factory for the D4GL-@@@A and to the lock position for the D4GL-@@@G. • To prevent the release key from being used by unauthorized personnel, set it to LOCK and seal it with sealing wax. Figure 1 Precautions for Safe Use Installation Environment • Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.) D4GL-@@@A-@ D4GL-@@@G-@ D4GL-@@@A-@4 D4GL-@@@G-@4 17 D4GL/D4GL-SK10-LK@ Hinged Door Head Direction If the Switch is mounted too close to the hinge, the force imposed on the lock will be much larger than for locations far from the hinge and the lock may be damaged. Mount the Switch close to the handle. Solenoid Lock Models The solenoid lock locks the door only when power is supplied to the solenoid. Therefore, the door will be unlocked if the power supply to the solenoid stops. Therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating. • Remove the four screws of the head to enable changing the mounting direction of the head. The head can be mounted in four directions. Ensure that no foreign material enters the interior of the Switch. Also, insert the head until the insertion line engraved on the head is hidden by the reference line on the Switch, as shown in the following diagram. • Do not insert or remove the Operation Key with the Switch head removed. Doing so may make it impossible to insert the Operation Key. Insertion line Mounting Reference line Appropriate Tightening Torque • Be sure to tighten each screw of the Switch properly. Loose screws may result in malfunction. Terminal screw 0.4 to 0.5 N·m Cover mounting screw 0.5 to 0.7 N·m Securing the Door Head mounting screw 0.5 to 0.6 N·m Operation Key mounting screw 2.4 to 2.8 N·m Switch mounting screw 1.3 to 1.5 N·m When the door is closed (with the Operation Key inserted), the Operation Key may exceed the set zone because of, for example, the door's own weight, machine vibration, or the door cushion rubber. Then, when an attempt is made to open the door, it may result in damage or malfunction. Also, it may not be possible to unlock the Switch if there is weight placed on the Operation Key. Do not rely on the Switch to substitute for a door locking device. Secure the door with a stopper so that the Operation Key remains within the set zone. 1.8 to 2.1 N·m Connector 1.4 to 1.8 N·m Cap screw 1.3 to 1.7 N·m • When loosening a screw with an electrical screwdriver or similar tool while pressing down on the screw head, do not continue turning the screw past the point where the threads disengage. Doing so may strip the end of the threads. Set zone (0.5 to 3 mm) Switch and Operation Key Mounting • Mount the Switch and Operation Key securely to the applicable tightening torque with M5 screws for the Switch and M4 screws for the Operation Key. Always use spring washers. To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and Operation Key from easily being removed. • Do not operate the Switch with anything other than the special OMRON Operation Key. Otherwise, the Switch may be damaged and the safety of the system may not be maintained. ] D4DS-K1/-K2 Four, M5 Two, M4 15 ±0.1 84 ±0.2 D4DS-K3 Two, M4 40 ±0.1 D4DS-K5 30 ±0.1 Two, M4 41±0.1 or 43±0.1 • Ensure that the alignment offset between the Operation Key and the key hole does not exceed ±1 mm. If the Operation Key is offset or at an angle, accelerated wear or damage to the Switch may result. • Observe the specified insertion radius for the Operation Key and insert it in a direction perpendicular to the key hole. • Do not impose excessive force on the Operation Key while the Key is inserted into the Switch or drop the Switch with the Operation Key inserted. Doing either of these may deform the Key or break the Switch. Operation key Solenoid • The solenoid will heat when it carries current. Do not touch it. • The solenoid has polarity. Confirm terminal polarity before wiring it. Wiring Circuit Connection Example for the D4GL-@H@@-A • Direct opening contacts used as safety-circuit inputs are indicated with the mark. Terminals 11 and 42, and terminals 21 and 22 have direct opening contacts. • Connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety-circuit inputs (redundancy circuit for terminals 11 and 12 and terminals 41 and 42 below). Connect the terminals individually when using as auxiliary-circuit inputs (e.g., terminals 21 and 22 for safety-door open/closed monitoring and terminals 51 and 52 for monitoring the lock status). • In the following connection example, terminals 21 and 22 and terminals 51 and 52 are used as auxiliary-circuit inputs. • Connect the indicators in parallel to the auxiliary circuits or terminals E1 and E2. • Although the 3 lines are connected at the time of delivery, rewire them as necessary for the application. 18 D4GL/D4GL-SK10-LK@ • The following table shows the connection configuration required to make the green indicator light when the door is closed and the orange indicator light when the solenoid turns ON. Terminal number Indicator Green indicator O1 Lead wire color Green Connected terminal number 31 Orange indicator O3 Orange E1 Common Black E2 O2 51 12 41 42 11 52 21 22 31 32 O1 (Green) LED (Green) Auxiliary circuit • Connect a recommended connector to the opening of the conduit and tighten the connector to the proper torque. The case may be damaged if excessive tightening torque is applied. • Make sure that the outer diameter of the cable connected to the connector is correct. • Attach a conduit cap to the unused conduit opening when wiring and tighten it to a suitable torque. The conduit cap is provided with the Switch. Recommended Connectors • Use a connector with a screw section not exceeding 10 mm. Otherwise the screws will protrude into the case interior. The connectors given in the following table have connectors with screw sections not exceeding 10 mm. Use the following connectors to ensure conformance to IP67. Auxiliary circuit Auxiliary circuit Size Manufacturer Model O2 (Black) E2 E1 O3 (Orange) Safety circuit Processing the Conduit Opening LAPP Solenoid G1/2 LED (Orange) Wiring Precautions • Do not wire the Switch while power is being supplied. Doing so may result in electric shock. • Do not let particles, such as small pieces of lead wire, enter the switch body when wiring. • Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm2). Use lead wires of an appropriate length. Not doing so may result in excess length causing the cover to rise and not fit properly. • Do not push crimp terminals into gaps in the case interior. Doing so may cause damage or deformation of the case. • Use crimp terminals that will not interfere with other components inside the case. ST-PF1/2 5380-1002 OHM ELECTRIC OA-W1609 CO. OA-W1611 Applicable cable diameter 6.0 to 12.0 mm 7.0 to 9.0 mm 9.0 to 11.0 mm Pg13.5 LAPP S-13.5 5301-5030 6.0 to 12.0 mm M20 LAPP ST-M20 × 1.5 5311-1020 7.0 to 13.0 mm Use LAPP connectors together with Seal Packing (JPK-16, GP-13.5, or GPM20), and tighten to the applicable torque. Seal Packing is sold separately. • LAPP is a German manufacturer. • OHM Electric Co. is a Japanese manufacturer. Recommended Crimp Terminals Manufacturer J.S.T. Mfg Co. Model FN0.5-3 (F Type) No. 5-3 (Straight Type) • The terminal block screws and contact numbers correspond as shown in the following diagram. The numbers are provided on the terminal cover. Confirm terminal numbers against the terminal block terminal symbols when wiring. 19 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved.
D4GL-1GFG-A 价格&库存

很抱歉,暂时无法提供与“D4GL-1GFG-A”相匹配的价格&库存,您可以联系我们找货

免费人工找货