Safety Limit Switch
D4N
Upgraded Safety Limit Switches Based on
the Popular D4D, Providing a Full Lineup
Conforming to International Standards
• Lineup includes three contact models with 2NC/1NO and 3NC
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC. Models with MBB contacts are also available.
• M12-connector models are available, saving on labor and
simplifying replacement.
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
• Conforms to EN115 and EN81-2.
• Lineup includes both slow-action and snap-action models with
Zb contacts.
• Certified standards: UL, EN (TÜV), and CCC
Note: Be sure to read the “Safety Precautions” on page 268.
Note: Contact your sales representative for details on models with
safety standard certification.
Model Number Structure
■ Model Number Legend
D4N-@@@@
1 2
3
1. Conduit/Connector size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
250
Safety Limit Switch D4N
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top plunger
32: Top roller plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE:Fork lever lock (right operation)
LE: Fork lever lock (left operation)
Ordering Information
■ List of Models
Switches with Two Contacts
Actuator
Conduit size
Built-in switch mechanism
1NC/1NO
(Snap-action)
Direct
opening
Roller lever (resin 1-conduit
lever, resin roller)
2-conduit
Roller lever (metal 1-conduit
lever, resin roller)
2-conduit
Roller lever (metal 1-conduit
lever, metal roller)
Roller lever (metal 1-conduit
lever, bearing
roller)
Plunger
1-conduit
2-conduit
Roller plunger
1-conduit
2-conduit
Model
2NC
(Snap-action)
Direct
opening
Model
1NC/1NO
(Slow-action)
Direct
opening
Model
2NC
(Slow-action)
Direct
opening
Model
Pg13.5
D4N-1120
D4N-1220
D4N-1A20
D4N-1B20
G1/2
D4N-2120
D4N-2220
D4N-2A20
D4N-2B20
1/2-14NPT
D4N-3120
D4N-3220
D4N-3A20
D4N-3B20
M20
D4N-4120
D4N-4220
D4N-4A20
D4N-4B20
D4N-9B20
M12 connector
D4N-9120
D4N-9220
D4N-9A20
Pg13.5
D4N-5120
D4N-5220
D4N-5A20
D4N-5B20
G1/2
D4N-6120
D4N-6220
D4N-6A20
D4N-6B20
M20
D4N-8120
D4N-8220
D4N-8A20
D4N-8B20
Pg13.5
D4N-1122
D4N-1222
D4N-1A22
D4N-1B22
G1/2
D4N-2122
D4N-2222
D4N-2A22
D4N-2B22
1/2-14NPT
D4N-3122
D4N-3222
D4N-3A22
D4N-3B22
M20
D4N-4122
D4N-4222
D4N-4A22
D4N-4B22
D4N-9B22
M12 connector
D4N-9122
D4N-9222
D4N-9A22
Pg13.5
D4N-5122
D4N-5222
D4N-5A22
D4N-5B22
G1/2
D4N-6122
D4N-6222
D4N-6A22
D4N-6B22
M20
D4N-8122
D4N-8222
D4N-8A22
D4N-8B22
Pg13.5
D4N-1125
D4N-1225
D4N-1A25
D4N-1B25
G1/2
D4N-2125
D4N-2225
D4N-2A25
D4N-2B25
1/2-14NPT
D4N-3125
D4N-3225
D4N-3A25
D4N-3B25
M20
D4N-4125
D4N-4225
D4N-4A25
D4N-4B25
D4N-9B25
M12 connector
D4N-9125
D4N-9225
D4N-9A25
Pg13.5
D4N-1126
D4N-1226
D4N-1A26
D4N-1B26
G1/2
D4N-2126
D4N-2226
D4N-2A26
D4N-2B26
1/2-14NPT
D4N-3126
D4N-3226
D4N-3A26
D4N-3B26
M20
D4N-4126
D4N-4226
D4N-4A26
D4N-4B26
D4N-9B26
M12 connector
D4N-9126
D4N-9226
D4N-9A26
Pg13.5
D4N-1131
D4N-1231
D4N-1A31
D4N-1B31
G1/2
D4N-2131
D4N-2231
D4N-2A31
D4N-2B31
1/2-14NPT
D4N-3131
D4N-3231
D4N-3A31
D4N-3B31
M20
D4N-4131
D4N-4231
D4N-4A31
D4N-4B31
D4N-9B31
M12 connector
D4N-9131
D4N-9231
D4N-9A31
Pg13.5
D4N-5131
D4N-5231
D4N-5A31
D4N-5B31
G1/2
D4N-6131
D4N-6231
D4N-6A31
D4N-6B31
M20
D4N-8131
D4N-8231
D4N-8A31
D4N-8B31
Pg13.5
D4N-1132
D4N-1232
D4N-1A32
D4N-1B32
G1/2
D4N-2132
D4N-2232
D4N-2A32
D4N-2B32
1/2-14NPT
D4N-3132
D4N-3232
D4N-3A32
D4N-3B32
M20
D4N-4132
D4N-4232
D4N-4A32
D4N-4B32
M12 connector
D4N-9132
D4N-9232
D4N-9A32
D4N-9B32
Pg13.5
D4N-5132
D4N-5232
D4N-5A32
D4N-5B32
G1/2
D4N-6132
D4N-6232
D4N-6A32
D4N-6B32
M20
D4N-8132
D4N-8232
D4N-8A32
D4N-8B32
Safety Limit Switch D4N
251
Actuator
Conduit size
Built-in switch mechanism
1NC/1NO
(Snap-action)
Direct
opening
One-way roller
arm lever
(horizontal)
1-conduit
2-conduit
One-way roller
arm lever
(vertical)
1-conduit
2-conduit
Adjustable roller 1-conduit
lever, form lock
(metal lever, resin
roller)
2-conduit
Adjustable roller
lever, form lock
(metal lever,
rubber roller)
1-conduit
2-conduit
Model
2NC
(Snap-action)
Direct
opening
Model
1NC/1NO
(Slow-action)
Direct
opening
Model
2NC
(Slow-action)
Direct
opening
Model
Pg13.5
D4N-1162
D4N-1262
D4N-1A62
D4N-1B62
G1/2
D4N-2162
D4N-2262
D4N-2A62
D4N-2B62
1/2-14NPT
D4N-3162
D4N-3262
D4N-3A62
D4N-3B62
M20
D4N-4162
D4N-4262
D4N-4A62
D4N-4B62
M12 connector
D4N-9162
D4N-9262
D4N-9A62
D4N-9B62
Pg13.5
D4N-5162
D4N-5262
D4N-5A62
D4N-5B62
G1/2
D4N-6162
D4N-6262
D4N-6A62
D4N-6B62
M20
D4N-8162
D4N-8262
D4N-8A62
D4N-8B62
Pg13.5
D4N-1172
D4N-1272
D4N-1A72
D4N-1B72
G1/2
D4N-2172
D4N-2272
D4N-2A72
D4N-2B72
1/2-14NPT
D4N-3172
D4N-3272
D4N-3A72
D4N-3B72
M20
D4N-4172
D4N-4272
D4N-4A72
D4N-4B72
M12 connector
D4N-9172
D4N-9272
D4N-9A72
D4N-9B72
Pg13.5
D4N-5172
D4N-5272
D4N-5A72
D4N-5B72
G1/2
D4N-6172
D4N-6272
D4N-6A72
D4N-6B72
M20
D4N-8172
D4N-8272
D4N-8A72
D4N-8B72
Pg13.5
D4N-112G
D4N-122G
D4N-1A2G
D4N-1B2G
G1/2
D4N-212G
D4N-222G
D4N-2A2G
D4N-2B2G
1/2-14NPT
D4N-312G
D4N-322G
D4N-3A2G
D4N-3B2G
M20
D4N-412G
D4N-422G
D4N-4A2G
D4N-4B2G
M12 connector
D4N-912G
D4N-922G
D4N-9A2G
D4N-9B2G
G1/2
D4N-612G
D4N-622G
D4N-6A2G
D4N-6B2G
M20
D4N-812G
D4N-822G
D4N-8A2G
D4N-8B2G
Pg13.5
D4N-112H
D4N-122H
D4N-1A2H
D4N-1B2H
G1/2
D4N-212H
D4N-222H
D4N-2A2H
D4N-2B2H
1/2-14NPT
D4N-312H
D4N-322H
D4N-3A2H
D4N-3B2H
M20
D4N-412H
D4N-422H
D4N-4A2H
D4N-4B2H
M12 connector
D4N-912H
D4N-922H
D4N-9A2H
D4N-9B2H
G1/2
D4N-612H
D4N-622H
D4N-6A2H
D4N-6B2H
M20
D4N-812H
D4N-822H
D4N-8A2H
D4N-8B2H
Note: It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
Switches with Three Contacts and MBB Contacts
Actuator
Conduit size
Built-in switch mechanism
2NC/1NO
(Slow-action)
Direct
opening
Roller lever (resin 1-conduit
lever, resin roller)
2-conduit
252
Model
3NC
(Slow-action)
Direct
opening
Model
1NC/1NO MBB
(Slow-action)
Direct
opening
Model
2NC/1NO MBB
(Slow-action)
Direct
opening
Model
Pg13.5
D4N-1C20
D4N-1D20
D4N-1E20
D4N-1F20
G1/2
D4N-2C20
D4N-2D20
D4N-2E20
D4N-2F20
1/2-14NPT
D4N-3C20
D4N-3D20
D4N-3E20
D4N-3F20
M20
D4N-4C20
D4N-4D20
D4N-4E20
D4N-4F20
M12 connector
---
---
D4N-9E20
---
Pg13.5
D4N-5C20
D4N-5D20
D4N-5E20
D4N-5F20
G1/2
D4N-6C20
D4N-6D20
D4N-6E20
D4N-6F20
M20
D4N-8C20
D4N-8D20
D4N-8E20
D4N-8F20
Safety Limit Switch D4N
Actuator
Conduit size
Built-in switch mechanism
2NC/1NO
(Slow-action)
Direct
opening
Roller lever (metal 1-conduit
lever, resin roller)
2-conduit
Roller lever (metal 1-conduit
lever, metal roller)
Roller lever (metal 1-conduit
lever, bearing
roller)
Plunger
1-conduit
2-conduit
Roller plunger
1-conduit
2-conduit
One-way roller
arm lever
(horizontal)
1-conduit
2-conduit
One-way roller
arm lever
(vertical)
1-conduit
2-conduit
Model
3NC
(Slow-action)
Direct
opening
Model
1NC/1NO MBB
(Slow-action)
Direct
opening
Model
2NC/1NO MBB
(Slow-action)
Direct
opening
Model
Pg13.5
D4N-1C22
D4N-1D22
D4N-1E22
D4N-1F22
G1/2
D4N-2C22
D4N-2D22
D4N-2E22
D4N-2F22
1/2-14NPT
D4N-3C22
D4N-3D22
D4N-3E22
D4N-3F22
M20
D4N-4C22
D4N-4D22
D4N-4E22
D4N-4F22
M12 connector
---
---
D4N-9E22
---
Pg13.5
D4N-5C22
D4N-5D22
D4N-5E22
D4N-5F22
G1/2
D4N-6C22
D4N-6D22
D4N-6E22
D4N-6F22
M20
D4N-8C22
D4N-8D22
D4N-8E22
D4N-8F22
Pg13.5
D4N-1C25
D4N-1D25
D4N-1E25
D4N-1F25
G1/2
D4N-2C25
D4N-2D25
D4N-2E25
D4N-2F25
1/2-14NPT
D4N-3C25
D4N-3D25
D4N-3E25
D4N-3F25
M20
D4N-4C25
D4N-4D25
D4N-4E25
D4N-4F25
M12 connector
---
---
D4N-9E25
---
Pg13.5
D4N-1C26
D4N-1D26
D4N-1E26
D4N-1F26
G1/2
D4N-2C26
D4N-2D26
D4N-2E26
D4N-2F26
1/2-14NPT
D4N-3C26
D4N-3D26
D4N-3E26
D4N-3F26
M20
D4N-4C26
D4N-4D26
D4N-4E26
D4N-4F26
M12 connector
---
---
D4N-9E26
---
Pg13.5
D4N-1C31
D4N-1D31
D4N-1E31
D4N-1F31
G1/2
D4N-2C31
D4N-2D31
D4N-2E31
D4N-2F31
1/2-14NPT
D4N-3C31
D4N-3D31
D4N-3E31
D4N-3F31
M20
D4N-4C31
D4N-4D31
D4N-4E31
D4N-4F31
M12 connector
---
---
D4N-9E31
---
Pg13.5
D4N-5C31
D4N-5D31
D4N-5E31
D4N-5F31
G1/2
D4N-6C31
D4N-6D31
D4N-6E31
D4N-6F31
M20
D4N-8C31
D4N-8D31
D4N-8E31
D4N-8F31
Pg13.5
D4N-1C32
D4N-1D32
D4N-1E32
D4N-1F32
G1/2
D4N-2C32
D4N-2D32
D4N-2E32
D4N-2F32
1/2-14NPT
D4N-3C32
D4N-3D32
D4N-3E32
D4N-3F32
M20
D4N-4C32
D4N-4D32
D4N-4E32
D4N-4F32
M12 connector
---
---
D4N-9E32
---
Pg13.5
D4N-5C32
D4N-5D32
D4N-5E32
D4N-5F32
G1/2
D4N-6C32
D4N-6D32
D4N-6E32
D4N-6F32
M20
D4N-8C32
D4N-8D32
D4N-8E32
D4N-8F32
Pg13.5
D4N-1C62
D4N-1D62
D4N-1E62
D4N-1F62
G1/2
D4N-2C62
D4N-2D62
D4N-2E62
D4N-2F62
1/2-14NPT
D4N-3C62
D4N-3D62
D4N-3E62
D4N-3F62
M20
D4N-4C62
D4N-4D62
D4N-4E62
D4N-4F62
M12 connector
---
---
D4N-9E62
----
Pg13.5
D4N-5C62
D4N-5D62
D4N-5E62
D4N-5F62
G1/2
D4N-6C62
D4N-6D62
D4N-6E62
D4N-6F62
M20
D4N-8C62
D4N-8D62
D4N-8E62
D4N-8F62
Pg13.5
D4N-1C72
D4N-1D72
D4N-1E72
D4N-1F72
G1/2
D4N-2C72
D4N-2D72
D4N-2E72
D4N-2F72
1/2-14NPT
D4N-3C72
D4N-3D72
D4N-3E72
D4N-3F72
M20
D4N-4C72
D4N-4D72
D4N-4E72
D4N-4F72
M12 connector
---
---
D4N-9E72
---
Pg13.5
D4N-5C72
D4N-5D72
D4N-5E72
D4N-5F72
G1/2
D4N-6C72
D4N-6D72
D4N-6E72
D4N-6F72
M20
D4N-8C72
D4N-8D72
D4N-8E72
D4N-8F72
Safety Limit Switch D4N
253
Actuator
Conduit size
Built-in switch mechanism
2NC/1NO
(Slow-action)
Direct
opening
Adjustable roller 1-conduit
lever, form lock
(metal lever, resin
roller)
2-conduit
Adjustable roller
lever, form lock
(metal lever,
rubber roller)
1-conduit
2-conduit
Model
3NC
(Slow-action)
Direct
opening
Model
1NC/1NO MBB
(Slow-action)
Direct
opening
Model
2NC/1NO MBB
(Slow-action)
Direct
opening
Model
Pg13.5
D4N-1C2G
D4N-1D2G
D4N-1E2G
D4N-1F2G
G1/2
D4N-2C2G
D4N-2D2G
D4N-2E2G
D4N-2F2G
1/2-14NPT
D4N-3C2G
D4N-3D2G
D4N-3E2G
D4N-3F2G
M20
D4N-4C2G
D4N-4D2G
D4N-4E2G
D4N-4F2G
M12 connector
---
---
D4N-9E2G
---
G1/2
D4N-6C2G
D4N-6D2G
D4N-6E2G
D4N-6F2G
M20
D4N-8C2G
D4N-8D2G
D4N-8E2G
D4N-8F2G
Pg13.5
D4N-1C2H
D4N-1D2H
D4N-1E2H
D4N-1F2H
G1/2
D4N-2C2H
D4N-2D2H
D4N-2E2H
D4N-2F2H
1/2-14NPT
D4N-3C2H
D4N-3D2H
D4N-3E2H
D4N-3F2H
M20
D4N-4C2H
D4N-4D2H
D4N-4E2H
D4N-4F2H
M12 connector
---
---
D4N-9E2H
---
G1/2
D4N-6C2H
D4N-6D2H
D4N-6E2H
D4N-6F2H
M20
D4N-8C2H
D4N-8D2H
D4N-8E2H
D4N-8F2H
Note: It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
General-purpose Switches with Two Contacts
Actuator
Conduit size
Built-in switch mechanism
1NC/1NO
(Snap-action)
Direct
opening
Fork lever lock
(right operation)
1-conduit
G1/2
---
Model
---
2NC
(Snap-action)
Direct
opening
---
Model
---
1NC/1NO
(Slow-action)
Direct
opening
---
1/2-14NPT
M20
2-conduit
G1/2
---
---
---
M20
Fork lever lock
(left operation)
1-conduit
G1/2
---
---
---
1/2-14NPT
M20
2-conduit
G1/2
---
---
---
M20
Cat whisker
1-conduit
2-conduit
G1/2
---
1-conduit
2-conduit
---
D4N-2280
D4N-3180
D4N-3280
M20
D4N-4180
D4N-4280
G1/2
---
M20
Plastic rod
D4N-2180
1/2-14NPT
G1/2
D4N-6180
---
D4N-8180
---
D4N-2187
D4N-6280
---
D4N-2287
D4N-3187
D4N-3287
M20
D4N-4187
D4N-4287
M20
---
D4N-6187
D4N-8187
Direct
opening
---
D4N-6287
D4N-8287
Model
D4N-2ARE ---
D4N-2BRE
D4N-3ARE
D4N-3BRE
D4N-4ARE
D4N-4BRE
D4N-6ARE ---
D4N-6BRE
D4N-8ARE
D4N-8BRE
D4N-2ALE ---
D4N-2BLE
D4N-3ALE
D4N-3BLE
D4N-4ALE
D4N-4BLE
D4N-6ALE ---
D4N-6BLE
D4N-8ALE
D4N-8BLE
---
---
D4N-2B80
D4N-3B80
D4N-4B80
---
---
D4N-8280
1/2-14NPT
G1/2
---
Model
2NC
(Slow-action)
D4N-6B80
D4N-8B80
---
---
D4N-2B87
D4N-3B87
D4N-4B87
---
---
D4N-6B87
D4N-8B87
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
254
Safety Limit Switch D4N
General-purpose Switches with Three Contacts and MBB Contacts
Actuator
Conduit size
Fork lever lock 1-conduit
(right operation)
2-conduit
G1/2
Built-in switch mechanism
Direct
2NC/1NO
Direct
3NC
Direct
opening (Slow-action) opening (Slow-action) opening
1NC/1NO
Direct
2NC/1NO
MBB
opening
MBB
(Slow-action)
(Slow-action)
---
D4N-2ERE
1-conduit
2-conduit
1-conduit
D4N-3FRE
D4N-4DRE
D4N-4ERE
D4N-4FRE
G1/2
---
G1/2
D4N-6CRE
---
D4N-8CRE
---
D4N-2CLE
D4N-6DRE
---
D4N-6ERE
D4N-8DRE
---
D4N-2DLE
---
D4N-6FRE
---
D4N-2FLE
D4N-8ERE
---
D4N-8FRE
D4N-2ELE
1/2-14NPT
D4N-3CLE
D4N-3DLE
D4N-3ELE
D4N-3FLE
M20
D4N-4CLE
D4N-4DLE
D4N-4ELE
D4N-4FLE
G1/2
---
G1/2
D4N-6CLE
---
D4N-8CLE
---
---
G1/2
G1/2
---
---
D4N-6ELE
D4N-2D80
---
D4N-6FLE
D4N-8ELE
---
D4N-8FLE
---
---
---
D4N-3D80
D4N-4D80
---
---
D4N-6D80
---
---
---
---
---
---
D4N-8D80
---
---
D4N-2D87
D4N-3D87
M20
G1/2
D4N-6DLE
D4N-8DLE
1/2-14NPT
2-conduit
D4N-2FRE
D4N-4CRE
M20
1-conduit
---
M20
M20
Plastic rod
---
D4N-3ERE
1/2-14NPT
2-conduit
D4N-2DRE
D4N-3DRE
M20
Cat whisker
---
D4N-3CRE
M20
Fork lever lock
(left operation)
D4N-2CRE
1/2-14NPT
D4N-4D87
---
---
M20
D4N-6D87
D4N-8D87
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Specifications
■ Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN60204-1
EN1088
GS-ET-15
■ Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Utilization
category
Item
Rated operating current (Ie)
AC-15
DC-13
3A
0.27 A
Rated operating voltage (Ue) 240 V
■ Certified Standards
Certification
body
TÜV Product
Service
Standard
EN60947-5-1
(certified direct opening)
File No.
(See note 1.)
UL (See note 2.)
UL508, CSA C22.2 No.14 E76675
CCC (CQC)
GB14048.5
2004010305105973
Note: 1. Consult your OMRON representative for details.
2. Certification for CSA C22.2 No. 14 is authorized by the UL
mark.
3. Ask your OMRON representative for information on certified
models.
250 V
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a
short-circuit protection device. This fuse is not built into the
Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated
voltage
120 VAC
Carry current
Current
Make
10 A
240 VAC
Break
60 A
6A
30 A
3A
Volt-amperes
Make
Break
7,200 VA 720 VA
Q300
Rated
voltage
125 VDC
250 VDC
Carry current
Current
Make
2.5 A
Break
0.55 A
0.55 A
0.27 A
0.27 A
Volt-amperes
Make
69 VA
Safety Limit Switch D4N
Break
69 VA
255
■ Characteristics
Degree of protection (See note 3.)
IP67 (EN60947-5-1)
Durability
(See note 4.)
Mechanical
15,000,000 operations min. (See note 7.)
Electrical
500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Operating speed
1 to 500 mm/s (D4N-1120)
Operating frequency
30 operations/minute max.
Contact resistance
25 m Ω max. (Initial value)
Minimum applicable load (See note 6.)
Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)
300 V
Protection against electric shock
Class II (double insulation)
Pollution degree (operating environment)
Level 3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1)
Between terminals of the same polarity: 2.5 kV
Between terminals of different polarities: 4 kV
Between other terminals and uncharged metallic parts: 6 kV
Insulation resistance
100 M Ω min.
Contact gap
Snap-action: 2 x 0.5 mm min
Slow-action: 2 x 2 mm min
Vibration resistance
Malfunction
Shock resistance
Destruction
10 to 55 Hz, 0.75-mm single amplitude
1,000 m/s2 min.
Malfunction
300 m/s2 min.
Conditional short-circuit current
100 A (EN60947-5-1)
Rated open thermal current (Ith)
10 A (EN60947-5-1)
Ambient temperature
Operating: −30°C to 70°C with no icing
Ambient humidity
Operating: 95% max.
Weight
Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-5120)
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in
roughening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration,
do not use the D4N in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head.
Otherwise, premature wear, Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. Do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the
actual load beforehand.
7. The mechanical durability of fork lever lock models is 10,000,000 operations min.
256
Safety Limit Switch D4N
Connections
■ Contact Form
Model
D4N-@1@
Contact
Contact form
1NC/1NO (Snapaction)
13
Zb
31
D4N-@2@
14
D4N-@B@
D4N-@D@
Remarks
ON
Stroke
11
12
31
32
1NC/1NO (Slowaction)
11-12
31-32
ON
Stroke
Zb
11
12
33
34
11-12
33-34
ON
Stroke
11
12
31
32
2NC/1NO (Slowaction)
ON
ON
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
Zb
11
12
21
22
33
34
Stroke
3NC (Slow-action)
Zb
D4N-@E@
D4N-@F@
11
12
21
22
31
32
1NC/1NO MBB
(Slow-action)
2NC/1NO MBB
(Slow-action)
11-12
21-22
31-32
ON
Zb
11
12
33
34
ON
12
21
22
33
34
11-12
21-22
33-34
ON
Stroke
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
Stroke
Zb
11
Only NC contacts 11-12, 21-22,
and 31-32 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
Stroke
11-12
33-34
Only NC contacts 11-12 have a
certified direct opening
mechanism.
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
Stroke
11-12
21-22
33-34
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
The terminals 11-12 and 33-34
can be used as unlike poles.
2NC (Slow-action)
11-12
31-32
Only NC contacts 31-32 have a
certified direct opening
mechanism.
The terminals 13-14 and 31-32
can be used as unlike poles.
2NC (Snap-action)
Zb
D4N-@C@
13-14
31-32
32
Zb
D4N-@A@
Operating pattern
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
Note: 1. Terminals are numbered according to EN50013 and the contact forms are according to IEC947-5-1.
2. MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally
open contact (NO) closes.
Safety Limit Switch D4N
257
Operation
■ Direct Opening Mechanism
1NC/1NO Contact (Slow-action)
Fixed contact (NC)
Contact spring
Movable contact
Fixed contact (NO)
Plunger
Return spring
Conforms to EN60947-5-1 Direct Opening Operation
(Only the NC contact side has a direct opening
mechanism.)
When contact welding occurs, the contacts are
separated from each other by the plunger being
pushed in.
2NC Contact (Slow-action)
Fixed contact (NC)
Movable contact
Contact spring
Plunger
Conforms to EN60947-5-1 Direct Opening Operation
(Both NC contacts have a direct opening
mechanism.)
Return spring
Nomenclature
■ Structure
Safety-oriented Lever Setting
(Form-lock construction)
Grooves which engage the lever are cut in the lever and
rotary shaft to prevent the lever from slipping against the
rotary shaft.
There are resin-lever and metal-lever types.
Head
The direction of the switch head can be varied to any of
the four directions. (Roller plunger models can be
mounted in either of two directions at a 90˚ angle.)
Conduit Opening
A wide variety of conduits is available.
Built-in Switch
The built-in switch has a direct opening mechanism
that forcibly separates the NC contact even when
there is contact deposit.
Cover
The cover, with a hinge on its lower part, can
be opened by removing the screw of the
cover, which ensures ease of maintenance
and wiring.
1-conduit
2-conduit
Pg13.5
Size
Yes
Yes
G1/2
Yes
Yes
1/2-14NPT
Yes
Yes
M20
Yes
Yes
M12 connector
Yes
---
Note: M12 connector types are not available for
Switches with three contacts.
258
Safety Limit Switch D4N
Dimensions
■ Switches
Note: All units are in millimeters unless otherwise indicated.
1-conduit Models
Roller Lever (Resin Lever, Resin Roller)
D4N-1@20
D4N-2@20
D4N-3@20
D4N-4@20
47
40
D4N-9@20 (See note 2.) 17.5 dia. × 6.8
Roller Lever (Metal Lever, Resin Roller)
D4N-1@22
D4N-2@22
D4N-3@22
D4N-4@22
45±
D4N-9@22 (See note 2.) 17.5 dia. × 6.8
39.5±
±1
resin roller
1
±1
1
(27)
resin roller
11±0.2
26R
Resin lever
26R
Metal lever
20.5 × 20.5
(31)
11±0.2
20.5 × 20.5
27.5
18
20±0.1
22±0.1
22±0.2
31 max.
55
14.2
30
Conduit cap
47±0.2
Two, 4+0.15
dia. holes
0
Depth: 5
22±0.2
31 max.
47±0.2
Conduit cap
Bearing roller
(31)
11±0.2
26R
14.2
30
26R
Metal lever
(31.5)
11±0.2
20.5 × 20.5
20.5 × 20.5
18
27.5
9±0.2
2.5
21.5
20±0.1
22±0.1
22±0.2
31 max.
55
47±0.2
21.5
20±0.1
22±0.1
2.15±0.05R
mounting holes
Conduit cap
Two, 4+0.15
dia. holes
0
Depth: 5
1
27.5
55
2.15±0.05R
mounting holes
1
1
9±0.2
2.5
21.5
20±0.1
22±0.1
Roller Lever (Metal Lever, Bearing Roller)
D4N-1@26
D4N-2@26
D4N-3@26
D4N-4@26
43.6±
D4N-9@26 (See note 2.) 17 dia. × 6
39±
39.5±1
sintered stainless
steel roller
Metal lever
2.5
2.15±0.05R
mounting holes
Roller Lever (Metal Lever, Metal Roller)
D4N-1@25
D4N-2@25
D4N-3@25
D4N-4@25
D4N-9@25 (See note 2.) 17.5 dia. × 7
45±
18
9±0.2
21.5
2.5
47±0.2
55
27.5
18
9±0.2
14.2
30
22±0.2
31 max.
Two, 4+0.15
dia. holes
0
Depth: 5
2.15±0.05R
mounting holes
Conduit cap
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to page 262 for details on M12 connectors.
Snap-action (1NC/1NO) (2NC), Slow-action
(2NC) (3NC)
Model
D4N-@120
D4N-@220
D4N-@B20
D4N-@D20
D4N-@122
D4N-@222
D4N-@B22
D4N-@D22
D4N-@125
D4N-@225
D4N-@B25
D4N-@D25
D4N-@126
D4N-@226
D4N-@B26
D4N-@D26
Slow-action (1NC/1NO) (2NC/1NO)
Model
D4N-@A20
D4N-@C20
D4N-@E20
D4N-@F20
OF max.
5.0 N
OF max.
5.0 N
RF min.
0.5 N
RF min.
0.5 N
PT (See note 1.)
18° to 27°
PT
18° to 27°
PT (2nd) (See note 2.) (44°)
OT min.
40°
PT (See note 3.)
MD max.
(See note 2.)
14°
PT (2nd) (See note 4.) (18°)
OT min.
40°
OP
---
OP
---
TT
(See note 3.)
(80°)
TT (See note 5.)
(80°)
DOT min.
(See note 4.)
50°
DOT min.
(See note 6.)
50°
DOF min.
(See note 4.)
20 N
DOF min.
(See note 6.)
20 N
Note: 1. Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact
operation.
2. Only for snap-action models.
3. Reference value.
4. For safe use, always make sure that the minimum values or greater
are provided.
D4N-@A22
D4N-@C22
D4N-@E22
D4N-@F22
D4N-@A25
D4N-@C25
D4N-@E25
D4N-@F25
D4N-@A26
D4N-@C26
D4N-@E26
D4N-@F26
27.5° to 36.5°
Note: 1. These PT values are possible when the NC contacts are open
(OFF).
2. These PT values are possible when the NO contacts are closed
(ON).
3. Only for MBB models.
4. Reference values for MBB models only.
5. Reference values.
6. For safe use, always make sure that the minimum values or greater
are provided.
Safety Limit Switch D4N
259
1-conduit Models
Roller Plunger
D4N-1@32
D4N-2@32
D4N-3@32
D4N-4@32
D4N-9@32 (See note 2.)
Plunger
D4N-1@31
D4N-2@31
D4N-3@31
D4N-4@31
D4N-9@31 (See note 2.)
25±0.1
Two, 3±0.05 dia.
holes
12 dia.
6-dia. resin
plunger
OP
OP
2.5
20±0.1
22±0.1
47±0.2
22±0.2
31 max.
55
Conduit cap
14.2
30
12.5 dia. × 5
resin roller
23.3 19.5±0.2
2.15±0.05R
mounting holes
dia. holes
Two, 4+0.15
0
Depth: 5
12 dia. × 5
resin roller
(31.5)
21.5
11±0.2
19.5±0.2
9±0.2
2.5
2.5
55
47±0.2
20±0.1
22±0.1
22±0.2
31 max.
Conduit cap
14.2
30
+0.15
0
Two, 4
dia. holes
Depth: 5
Safety Limit Switch D4N
2.15±0.05R
mounting holes
Operating
direction
55
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to page 262 for details on M12 connectors.
260
14.2
30
10.2
9±0.2
22±0.2
31 max.
OP
12
11±0.2
10.2
47±0.2
Conduit cap
R19 14.7
20R
20±0.1
22±0.1
2.15±0.05R
mounting holes
22±0.2
31 max.
dia. holes
Two, 4+0.15
0
Depth: 5
(31.5)
21.5
11±0.2
14.8
13.5
20±0.1
22±0.1
One-way Roller Arm Lever
(Vertical)
D4N-1@72
D4N-2@72
D4N-3@72
D4N-4@72
D4N-9@72 (See note 2.)
Operating direction
11±0.2
47±0.2
2.15±0.05R
mounting holes
One-way Roller Arm Lever
(Horizontal)
D4N-1@62
D4N-2@62
D4N-3@62
D4N-4@62
D4N-9@62 (See note 2.)
OP
25.2
9±0.2
9±0.2
2.5
55
20.5 × 20.5
9.5 dia. × 5
resin roller
(31.5)
21.5
11±0.2
(31.5)
21.5
11±0.2
Conduit cap
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-@132
D4N-@232
D4N-@B32
D4N-@D32
D4N-@162
D4N-@262
D4N-@B62
D4N-@D62
D4N-@172
D4N-@272
D4N-@B72
D4N-@D72
OF max.
6.5 N
6.5 N
5.0 N
5.0 N
RF min.
1.5 N
1.5 N
0.8 N
0.8 N
PT max.
2 mm
2 mm
4 mm
4 mm
OT min.
4 mm
4 mm
5 mm
5 mm
MD max.
1 mm
(See note 2.)
1 mm
1.5 mm
1.5 mm
28.6
±0.8 mm
37 ±0.8 mm 27 ±0.8 mm
TT
(6 mm)
(See note 3.)
(6 mm)
(9 mm)
(9 mm)
DOT min.
3.2 mm
(See note 4.)
3.2 mm
5.8 mm
4.8 mm
DOF min.
20 N
(See note 4.)
20 N
20 N
20 N
OP
18.2
±0.5 mm
Note: 1. Variation occurs in the simultaneity of contact opening/
closing operations of 2NC, 2NC/1NO, and 3NC contacts.
Check contact operation.
2. Only for snap-action models.
3. Reference value.
4. For safe use, always make sure that the minimum values or
greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Model
D4N-@A31
D4N-@C31
D4N-@E31
D4N-@F31
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
D4N-@A62
D4N-@C62
D4N-@E62
D4N-@F62
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
OF max.
6.5 N
6.5 N
5.0 N
5.0 N
RF min.
1.5 N
1.5 N
0.8 N
0.8 N
PT max.
2 mm
(See note 1.)
2 mm
4 mm
4 mm
PT (2nd)
(2.9 mm)
(See note 2.)
(2.9 mm)
(5.2 mm)
(4.3 mm)
PT max.
2.8 mm
(See note 3.)
2.8 mm
4 mm
4 mm
PT (2nd)
(1 mm)
(See note 4.)
(1 mm)
(1.5 mm)
(1.5 mm)
5 mm
OT min.
OP
4 mm
4 mm
5 mm
18.2
±0.5 mm
28.6
±0.8 mm
37 ±0.8 mm 27 ±0.8 mm
OP
17.4
(See note 5.) ±0.5 mm
28 ±0.8 mm 36 ±0.8 mm 26.1
±0.8 mm
TT
(6 mm)
(See note 6.)
(6 mm)
(9 mm)
(9 mm)
DOT min.
3.2 mm
(See note 7.)
3.2 mm
5.8 mm
4.8 mm
DOF min.
20 N
(See note 7.)
20 N
20 N
20 N
Note: 1. These PT values are possible when the NC contacts are
open (OFF).
2. These PT values are possible when the NO contacts are
closed (ON).
3. Only for MBB models.
4. Reference values for MBB models.
5. Only for MBB models.
6. Reference value.
7. For safe use, always make sure that the minimum values or
greater are provided.
Safety Limit Switch D4N
261
1-conduit Models
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-1@2G
D4N-2@2G
D4N-3@2G
D4N-4@2G
D4N-9@2G (See note 2.) 17.5 dia. × 6.8
resin roller
20 to 66R
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-1@2H
D4N-2@2H
D4N-3@2H
D4N-4@2H
D4N-9@2H (See note 2.) 50 dia. × 8
45±1
39.5±1
(31)
Bearing
11±0.2
rubber roller
20.5 × 20.5
48.2±1
41.3±1
(29.2)
11±0.2
32 to 66R
18
27.5
21.5
2.5
55
20.5×20.5
9±0.2
47±0.2
20±0.1
22±0.1
18
27.5
9±0.2
2.15±0.05R
mounting holes
55
Conduit cap
22±0.2
31 max.
21.5
2.5
47±0.2
20±0.1
22±0.1
2.15±0.05R
mounting holes
Stainless steel
lever
14.2
dia. holes
Two, 4+0.15
0
30
Depth: 5
22±0.2
31 max.
Conduit cap
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to following diagrams for details on M12 connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model
D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
OF max.
4.5 N
RF min.
0.4 N
PT
18° to 27°
OT min.
40°
MD max. (See note 3.)
14°
OP
---
TT (See note 4.)
(80°)
DOT min. (See note 5.)
50°
DOF min. (See note 5.)
20 N
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
(See note 2.)
Note: 1. Variation occurs in the simultaneity of contact opening/
closing operations of 2NC, 2NC/1NO, and 3NC contacts.
Check contact operation.
2. The operating characteristics of these Switches were
measured with the roller lever set at 32 mm.
3. Only for snap-action models.
4. Reference value.
5. For safe use, always make sure that the minimum values or
greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Model
D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
OF max.
4.5 N
RF min.
0.4 N
PT (See note 2.)
18° to 27°
PT (2nd) (See note 3.)
(44°)
PT (See note 4.)
27.5° to 36.5°
PT (2nd) (See note 5.)
(18°)
OT min.
40°
OP
---
TT (See note 6.)
(80°)
DOT min.
50°
DOF min. (See note 7.)
20 N
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
(See note 1.)
1-conduit M12 Connector
D4N-9@@@
(14)
M12 × 1
14.2
30
262
Safety Limit Switch D4N
Note: 1. The operating characteristics of these Switches were
measured with the roller lever set at 32 mm.
2. This PT value is possible when the NC contacts are open
(OFF).
3. This PT value is possible when the NO contacts are closed
(ON).
4. Only for MBB models.
5. Reference value for MBB models only.
6. Reference value.
7. For safe use, always make sure that the minimum values or
greater are provided.
1-conduit Models
Fork Lever Lock
(Left Operation)
D4N-1@LE
D4N-2@LE
D4N-3@LE
D4N-4@LE
Fork Lever Lock
(Right Operation)
D4N-1@RE
D4N-2@RE
D4N-3@RE
D4N-4@RE
Two, 17.5 dia.
× 8 rubber
rollers
47 max.
39.3±1
47 max.
39.3±1
(27.2)
90°
90°
11±0.2
11±0.2
26R
Two, 17.5 dia. ×
8 rubber rollers
(27.2)
26R
20.5 × 20.5
20.5 × 20.5
27.5
9±0.2
55
21.5
21.5
2.5
20±0.1
22±0.1
47±0.2
Cat Whisker
D4N-1@80
D4N-3@80
2.15±0.05R
mounting holes
2.15±0.05R
mounting
holes
22±0.2
Conduit cap
31 max.
14.2
30
+0.15
0
Two, 4
dia. holes
Depth: 5
20.5 × 20.5
Two, 4+0.15
dia. holes 14.2
0
30
Depth: 5
Plastic Rod
D4N-1@87
D4N-3@87
D4N-2@80
D4N-4@80
PT
1.2-dia.
stainless
steel wire
(See
note 2.)
42
47±0.2
20.5 ×
20.5
21.5
47±0.2
20±0.1
22±0.1
22±0.2
31 max.
14.2
Two, 4+0.15
dia. holes
0
30
Depth: 5
11±0.2
9±0.2
2.5
(31.5)
22±0.2
31 max.
Sealing cap
12±0.2
2.15±0.05R
mounting holes
Conduit cap
55
PT
16.6 dia.
55
22±0.2
31 max.
47±0.2
16.6 dia.
9±0.2
55
2.5
Resin rod
(See note 2.)
21.5
11±0.2
20±0.1
22±0.1
20±0.1
22±0.1
D4N-2@87
D4N-4@87
115
Sealing cap
2.5
Conduit cap
38
143.1
(50.1)
18
9±0.2
27.5
18
2.15±0.05R
mounting holes
Conduit cap
14.2
30
(31.5)
Two, 4+0.15
dia. holes
0
Depth: 5
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The usable range for stainless steel wires and resin rods is 35 mm max. from the end with a total travel of 70 mm max.
Slow-action (1NC/1NO) (2NC/1NO) (2NC) (3NC)
Model
D4N-@@RE
D4N-@@LE
Force necessary to reverse
the direction of the lever:
max.
6.4 N
6.4 N
Movement until the lever
reverses
55 ±10°
55 ±10°
Movement until switch
operation (NC)
6.5°
(MBB: 10°)
6.5°
(MBB: 10°)
Movement until switch
operation (NO)
18.5°
(MBB: 5°)
18.5°
(MBB: 5°)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model
D4N-@@80
D4N-@@87
OF max.
1.5 N
1.5 N
PT max.
15°
15°
Safety Limit Switch D4N
263
2-conduit Models
Roller Lever (Resin Lever, Resin Roller)
D4N-5@20
17.5 dia. × 6.8
D4N-6@20
resin roller
D4N-8@20
26R
(27)
11±0.2
Resin lever
18
20.5 × 20.5
5.4
2.5
20±0.1
22±0.1
40±0.1
42±0.1
25 dia.
18
20.5
(3)
Conduit cap
6-dia. resin plunger
OP
2.15±0.05R
mounting
holes
Conduit cap
20±0.1
22±0.1
40±0.1
42±0.1
(31.5)
21.5
11±0.2
42±0.2
56 max.
(3)
20.5 × 20.5
14.2
30
(31.5)
21.5
11±0.2
9.5 dia. × 5
resin roller
OP 25.2
2.5
9±0.2
5.4
9±0.2
20.5
2.15±0.05R
mounting
holes
Cap
Conduit cap
39±0.2
25 dia.
42±0.2
56 max.
47
Cap
2.5
20±0.1
22±0.1
40±0.1
42±0.1
20.5
39±0.2
25 dia.
Two, 4+0.15
dia. holes
0
Depth: 5
Roller Plunger
D4N-5@32
D4N-6@32
D4N-8@32
Two, 3±0.05
dia. holes
27.5
21.5
9±0.2
2.15±0.05R
mounting
holes
14.2
30
25±0.1
5.4
2.5
47
Cap
12 dia.
11±0.2
20.5 × 20.5
5.4
dia. holes
Two, 4+0.15
0
Depth: 5
Plunger
D4N-5@31
D4N-6@31
D4N-8@31
(31)
27.5
39±0.2
42±0.2
56 max.
45±1
39.5±1
26R
Metal lever
21.5
9±0.2
2.15±0.05R
mounting
holes
Conduit cap
Roller Lever (Metal Lever, Resin Roller)
D4N-5@22
D4N-6@22
17.5 dia. × 6.8
D4N-8@22
resin roller
47±1
40±1
47
(3)
20±0.1
22±0.1
40±0.1
42±0.1
20.5
39±0.2
25 dia.
47
Cap
42±0.2
56 max.
(3)
14.2
30
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Two, 4+0.15
dia. holes
0
Depth: 5
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action
(2NC) (3NC)
Model
D4N-@120
D4N-@220
D4N-@B20
D4N-@D20
D4N-@122
D4N-@222
D4N-@B22
D4N-@D22
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-@132
D4N-@232
D4N-@B32
D4N-@D32
Slow-action (1NC/1NO) (2NC/1NO)
Model
D4N-@A20
D4N-@C20
D4N-@E20
D4N-@F20
D4N-@A22
D4N-@C22
D4N-@E22
D4N-@F22
D4N-@A31
D4N-@C31
D4N-@E31
D4N-@F31
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
OF max.
5N
5N
6.5 N
OF max.
5N
5N
6.5 N
6.5 N
RF min.
0.5 N
0.5 N
1.5 N
6.5 N
1.5 N
RF min.
0.5 N
0.5 N
1.5 N
1.5 N
PT
(See note 1.)
18° to 27°
18° to 27°
2 mm
2 mm
PT (2nd)
(See note 2.)
(44°)
(44 °)
(2.9 mm)
(2.9 mm)
PT
18° to 27°
18° to 27°
2 mm
2 mm
OT min.
40°
40°
4 mm
4 mm
MD max.
(See note 2.)
14°
14°
1 mm
1 mm
PT
(See note 3.)
27.5° to 36.5° 27.5° to 36.5° 2.8 mm
2.8 mm
OP
---
---
18 ±0.5 mm
28.2
±0.8 mm
PT (2nd)
(See note 4.)
(18°)
(1 mm)
TT
(See note 3.)
(80°)
(80°)
(6 mm)
(6 mm)
DOT min.
(See note 4.)
50°
50°
3.2 mm
3.2 mm
DOF min.
(See note 4.)
20 N
20 N
20 N
20 N
Note: 1. Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact
operation.
2. Only for snap-action models.
3. Reference value.
4. For safe use, always make sure that the minimum values or greater
are provided.
264
Safety Limit Switch D4N
(18 °)
(1 mm)
OT min.
40°
40°
4 mm
4 mm
OP
---
---
18 ±0.5 mm
28.2
±0.8 mm
OP
(See note 5.)
---
---
17.4
±0.5 mm
28 ±0.8 mm
TT
(See note 6.)
(80°)
(80 °)
(6 mm)
(6 mm)
DOT min.
(See note 7.)
50°
50°
3.2 mm
3.2 mm
DOF min.
(See note 7.)
20 N
20 N
20 N
20 N
Note: 1.
2.
3.
4.
5.
6.
7.
This PT value is possible when the NC contacts are open (OFF).
This PT value is possible when the NO contacts are closed (ON).
Only for MBB models.
Reference value for MBB models.
Only for MBB models.
Reference value.
For safe use, always make sure that the minimum values or greater
are provided.
2-conduit Models
One-way Roller Arm Lever
Operating direction
(Horizontal)
14.8
D4N-5@62
12 dia. x 5
D4N-6@62
±0.2
11
resin roller
D4N-8@62
13.5
OP
2.15±0.05R
mounting holes
21.5
11±0.2
20R
23.3
5.4
19.5±0.2
One-way Roller Arm Lever
(Vertical)
D4N-5@72
D4N-6@72
OP
D4N-8@72
12
11±0.2
(31.5)
47
20±0.1
22±0.1
40±0.1
42±0.1
Cap
(3)
2.15±0.05R
mounting
holes
Conduit cap
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-6@2G
17.5 dia. × 6.8
resin roller
D4N-8@2G
18
19.5±0.2
9±0.2
20.5
39±0.2
Conduit cap
Resin lever
2.15±0.05R
mounting holes
14.7
2.5
10.2
5.4
25 dia.
19R
21.5
9±0.2
42±0.2
56 max.
21.5
11±0.2
12 dia. × 5
resin roller
10.2
2.5
20±0.1
22±0.1
40±0.1
42±0.1
(31.5)
11±0.2
20 to 66R
25 dia.
20.5
47
Cap
42±0.2
56 max.
Operating
direction
(3)
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-6@2H
50 dia. × 8
rubber roller
D4N-8@2H Bearing
45±1
39.5±1
(31)
21.5
39±0.2
48.2±1
41.3±1
(29.2)
20.5 × 20.5
5.4
2.5
27.5
21.5
9±0.2
25 dia.
18
20.5
39±0.2
20±0.1
22±0.1
40±0.1
42±0.1
11±0.2
47
Conduit cap
(3)
5.4
14.2
30
20.5 × 20.5
2.5
27.5
21.5
9±0.2
20.5
39±0.2
20±0.1
22±0.1
40±0.1
42±0.1
Cap
42±0.2
56 max.
32 to 66R
Stainless
steel lever
2.15±0.05R
mounting holes
25 dia.
47
Cap
Conduit cap
42±0.2
56 max.
Two, 4+0.15
dia. holes
0
Depth: 5
(3)
14.2
30
Two, 4+0.15
dia. holes
0
Depth: 5
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action
(2NC) (3NC)
Model
OF max.
D4N-@162
D4N-@262
D4N-@B62
D4N-@D62
5.0 N
D4N-@172
D4N-@272
D4N-@B72
D4N-@D72
5.0 N
Slow-action (1NC/1NO) (2NC/1NO)
Model
D4N-@A62
D4N-@C62
D4N-@E62
D4N-@F62
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
(See note 1.)
D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
(See note 2.)
5.0 N
4.5 N
4.5 N
0.8 N
0.4 N
0.4 N
4 mm
4 mm
18° to 27°
18° to 27°
PT (2nd)
(See note 4.)
(5.2 mm)
(4.3 mm)
(44°)
(44°)
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
(See note 2.)
D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
(See note 3.)
OF max.
5.0 N
4.5 N
4.5 N
RF min.
0.8 N
PT max.
(See note 3.)
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
RF min.
0.8 N
0.8 N
0.4 N
0.4 N
PT max.
4 mm
4 mm
18° to 27°
18° to 27°
OT min.
5 mm
5 mm
40°
40°
MD max.
(See note 4.)
1.5 mm
1.5 mm
14°
14°
PT max.
(See note 5.)
4 mm
4 mm
27.5° to 36.5°
27.5° to 36.5°
OP
37 ±0.8 mm
27 ±0.8 mm
---
---
(1.5 mm)
(18°)
(18°)
(9 mm)
(9 mm)
(70°)
(70°)
PT (2nd)
(See note 6.)
(1.5 mm)
TT
(See note 5.)
OT min.
5 mm
5 mm
40°
40°
DOT min.
(See note 6.)
5.8 mm
4.8 mm
50°
50°
OP
37 ±0.8 mm
27 ±0.8 mm
---
---
20 N
26.1 ±0.8 mm
---
20 N
36 ±0.8 mm
---
DOF min.
(See note 6.)
OP
(See note 7.)
TT
(See note 8.)
(9 mm)
(9 mm)
(70°)
(70°)
DOT min.
(See note 9.)
5.8 mm
4.8 mm
50°
50°
DOF min.
(See note 9.)
20 N
20 N
20 N
20 N
20 N
20 N
Note: 1. Variation occurs in the simultaneity of contact opening/closing operations
of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
2. The operating characteristics of these Switches were measured with the
roller lever set at 30 mm.
3. The operating characteristics of these Switches were measured with the
roller lever set at 31 mm.
4. Only for snap-action models.
5. Reference value.
6. For safe use, always make sure that the minimum values or greater are
provided.
Note: 1. The operating characteristics of these Switches were measured with the
roller lever set at 30 mm.
2. The operating characteristics of these Switches were measured with the
roller lever set at 31 mm.
3. This PT value is possible when the NC contacts are open (OFF).
4. This PT value is possible when the NO contacts are closed (ON).
5. Only for MBB models.
6. Reference value for MBB models only.
7. Only for MBB models.
8. Reference value.
9. For safe use, always make sure that the minimum values or greater are
provided.
Safety Limit Switch D4N
265
2-conduit Models
Fork Lever Lock
(Right Operation)
D4N-5@RE
D4N-6@RE
D4N-7@RE
D4N-8@RE
Fork Lever Lock
(Left Operation)
D4N-5@LE
D4N-6@LE
D4N-7@LE
D4N-8@LE
47 max.
39.3±1
Two, 17.5 dia. ×
8 rubber rollers
(27.2)
90°
11±0.2
Two, 17.5 dia. ×
8 rubber rollers
20.5 × 20.5
(27.2)
90°
27.5
11±0.2
26R
21.5
20.5 × 20.5
18
5.4
2.5
20±0.1
22±0.1
40±0.1
42±0.1
20.5
27.5
9±0.2
2.15±0.05R
mounting holes
26R
47 max.
39.3±1
5.4
2.5
9±0.2
20±0.1
22±0.1
40±0.1
42±0.1
2.15±0.05R
mounting holes
Conduit cap
21.5
20.5
39±0.2
25 dia.
18
Two, 4+0.15
dia. holes
0
Depth: 5
47
39±0.2
25 dia.
42±0.2
56 max.
14.2
30
(3)
47
Cap
Cap
Conduit cap
42±0.2
56 max.
(3)
14.2
Two, 4+0.15
dia. holes
30
0
Depth: 5
Cat Whisker
D4N-5@80
D4N-7@80
Plastic Rod
D4N-5@87
D4N-7@87
D4N-6@80
D4N-8@80
1.2-dia.
stainless
steel wire
(See
note 2.)
PT
20.5 × 20.5
5.4
16.6 dia.
11±0.2
2.5
20±0.1
22±0.1
40±0.1
42±0.1
5.4
20.5
2.15±0.05R
mounting
holes
Cap
Conduit cap
(3)
14.2
30
21.5
115
16.6 dia.
Sealing cap
11±0.2
2.5
12±0.2
39±0.2
25 dia.
47
42±0.2
56 max.
Resin rod
(See note 2.)
21.5
9±0.2
2.15±0.05R
mounting holes
PT
38
42
143.1
(50.1)
Sealing cap
D4N-6@87
D4N-8@87
9±0.2
20±0.1
22±0.1
40±0.1
42±0.1
20.5
39±0.2
25 dia.
47
Cap
42±0.2
56 max.
(3)
(31.5)
14.2
30
(31.5)
Two, 4+0.15
dia. holes
0
Depth: 5
Two, 4+0.15
dia. holes
0
Depth: 5
Conduit cap
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The usable range for stainless steel wires and resin rods is 35 mm max. from the end with a total travel of 70 mm max.
Slow-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model
D4N-@@RE
D4N-@@LE
Force necessary to reverse the
direction of the lever: max.
6.4 N
6.4 N
Movement until the lever
reverses
55 ±10°
55 ±10°
Movement until switch operation (6.5°)
(NC)
(6.5°)
(MBB: 10°)
Movement until switch operation (18.5°)
(NO)
(18.5°)
(MBB: 5°)
Snap-action (1NC/1NO), Slow-action (2NC) (3NC)
Model
D4N-@@80
D4N-@@87
OF max.
1.5 N
1.5 N
PT max.
15°
15°
266
Safety Limit Switch D4N
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
■ Levers
Refer to the following for the angles and positions of the watchdogs (source: EN50047.)
Roller Lever
(D4N-@@20)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
(D4N-@@2G) (Reference Values)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
(D4N-@@2H) (Reference Values)
30±7
40±2
10 min.
40±2
Dog
30°
29±7
Dog
10 min.
15±3
42±2
11±3
45 min.
10 min.
30°
Dog
40 min.
5±2
20 min. 30°
25 min.
110
55
5 min.
40+10
15 min.
90
30°
70+10
45
35+10
50
65R 31R
65R 20R
Sealed Plunger
(D4N-@@31)
75
55+10
55+10
Roller Plunger
(D4N-@@32)
0
12.5 −2.5
10±1.5
0
12.5 −2.5
Dog
Dog
Operating position
15 min. 18±0.5 21 min.
35
25+10
One-way Roller Arm Lever
(Horizontal)
(D4N-@@62)
Operating position
2.5
20 min. 30°
Dog
25 min. 28±1
10 min.
31 min.
One-way Roller Arm Lever
(Vertical) (Reference Values)
(D4N-@@72)
0
12.5 −2.5
0
12.5 −2.5
10±2
Dog
31
10 min.
5 min.
20 min. 30°
30°
Dog
5 min.
40
31+10
41±2
10 min.
30 max.
22+10 20 min.
Fork Lever Lock
(Right Operation)
(D4N-@@RE)
Fork Lever Lock
(Left Operation)
(D4N-@@LE)
40
40
Mounting
surface
55° to 60°
60
5 to 9R
28
36
Mounting
surface
55° to 60°
60
36
28
Dog setting range
5 to 9R
Dog setting range
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Safety Limit Switch D4N
267
Safety Precautions
Refer to the “Precautions for All Safety Switches” on page 240 and “Precautions for All Safety Limit Switches” on page 247.
• Locations where the interior of the Protective Door may come
into direct contact with cutting chips, metal filings, oil, or
chemicals
!CAUTION
Do not use metal connectors or conduits. If the Switch is
made of resin, damage at the conduit section may cause
electric shock.
■ Precautions for Safe Use
• Locations where the Switch may come into contact with thinner
or detergents
Mounting Method
• Do not drop the Switch. Doing so may result in the Switch not
performing to its full capacity.
• Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction.
• Do not use the Switch where explosive gas or flammable gas may
be present.
• Do not use the Switch submerged in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil or water entering the Switch interior. (The IP67 degree of
protection specification for the Switch refers to water penetration
while the Switch is submersed in water for a specified period of
time.)
• Protect the head from foreign material. Subjecting the head to
foreign material may result in premature wear or damage to the
Switch. Although the switch body is protected from penetration by
dust or water, the head is not protected from penetration by minute
particles or water.
• Turn the power OFF before wiring. Not doing so may result in
electric shock.
• Install the cover after wiring. Not doing so may result in electric
shock.
• Connect a fuse to the Switch in series to protect the Switch from
short-circuit damage. Use a fuse with a breaking current 1.5 to 2
times larger than the rated current. To conform to EN ratings, use
an IEC60269-compliant 10-A fuse type gI or gG.
• Do not switch circuits for two or more standard loads (250 VAC,
3 A) at the same time. Doing so may adversely affect insulation
performance.
• The durability of the Switch is greatly affected by operating
conditions. Evaluate the Switch under actual working conditions
before permanent installation and use within a number of switching
operations that will not adversely affect the Switch’s performance.
• Be sure to indicate in the machine manufacturer’s instruction
manual that the user must not attempt to repair or maintain the
Switch and must contact the machine manufacturer for any repairs
or maintenance.
• Check the Switches before use and inspect regularly, replacing
them when necessary. If a Switch is kept pressed for an extended
period of time, the components may deteriorate quickly, and the
Switch may not release.
Mounting Screw Tightening Torque
■ Precautions for Correct Use
Switch Mounting Holes
Tighten each of the screws to the specified torque. Loose screws
may result in malfunction of the Switch within a short time.
1
Terminal screw
0.6 to 0.8 N·m
2
Cover clamping screw
0.5 to 0.7 N·m
3
Head clamping screw
0.5 to 0.6 N·m
4
Lever clamping screw
1.6 to 1.8 N·m
5
Body clamping screw
0.5 to 0.7 N·m
6
Conduit mounting
connection, M12 adaptor
1.8 to 2.2 N·m (except 1/214NPT)
7
Cap screw
1.4 to 1.8 N·m (1/2-14NPT)
1.3 to 1.7 N·m
3
4
5
1
7
6
2
Switch Mounting
• Mount the Switch using M4 screws and washers and tighten the
screws to the specified torque.
• For safety, use screws that cannot be easily removed, or use an
equivalent measure to ensure that the Switch is secure.
• Secure the Switch with two M4 bolts and washers. Provide studs
with a diameter of 4 −−0.05
0.15 and a height of 4.8 mm max. at two places,
inserting into the holes at the bottom of the Switch as shown below
so that the Switch is firmly fixed at four points.
One-conduit Type
Environment
• The Switch is intended for indoor use only.
• Do not use the Switch outdoors. Doing so may cause the Switch to
malfunction.
• Do not use the Switch where corrosive gases (e.g., H2S, SO2, NH3,
HNO3, CI2) are present or in locations subject to high temperature
and humidity. Doing so may result in damage to the Switch caused
by contact failure or corrosion.
• Do not use the Switches in the following locations.
• Locations subject to severe temperature changes
• Locations subject to high temperatures or condensation
• Locations subject to severe vibration
268
Safety Limit Switch D4N
2.5±0.1
Two, M4
Two-conduit Type
2.5±0.1
Two, M4
5.35±0.1
20±0.1
22±0.1
39±0.1
47±0.1
20±0.1
22±0.1
40±0.1
42±0.1
42±0.1
22±0.1
4−0.05
−0.15 dia.
Height: 4.8 max.
4−0.05
−0.15 dia.
Height: 4.8 max.
• Make sure that the dog contacts the actuator at a right angle.
Applying a load to the switch actuator (roller) on a slant may result
in deformation or damage of the actuator or rotary shaft.
Contact Arrangement
• The following diagrams show the contact arrangements used for
screw terminal types and connector types.
Screw Terminal Type
Dog
Dog
D4N-@C@@ (2NC/1NO)
D4N-@F@@ (2NC/1NO (MBB))
D4N-@D@@ (3NC)
Incorrect
Correct
Wiring
• When connecting to the terminals via insulating tube and M3.5
crimp terminals, arrange the crimp terminals as shown below so
that they do not rise up onto the case or the cover. Applicable lead
wire size: AWG20 to AWG18 (0.5 to 0.75 mm2).
Use lead wires of an appropriate length, as shown below. Not doing
so may result in excess length causing the cover to rise and not fit
properly.
11
12
11
21
22
21
22
31
32
33
34
D4N-@B@@ (2NC)
D4N-@2@@ (2NC (SNAP))
12
11
12
31
32
33
34
D4N-@1@@ (1NC/1NO (SNAP))
AB
B
11 12
C
21 22
D
E
33 34
F
42 mm
33 mm
28 mm
Left hand
Right hand
ECA
21 22
33 34
12 (2)
(1) 11
12 (2)
32 (4)
(3) 33
34 (4)
D4N-91@@ (1NC/1NO (SNAP))
1
2
D
42 mm
28 mm
F
28 mm
D4N-9A@@ (1NC/1NO)
D4N-9E@@ (1NC/1NO (MBB))
(3) 31
BD F
ECA
42 mm
E
32
(1) 11
B
BD F
C
31
Connector Type
D4N-9B@@ (2NC)
D4N-92@@ (2NC (SNAP))
Two-conduit Type (3 Poles)
11 12
14
F
Tolerance ±2 mm
A
13
D
E
C
D4N-@A@@ (1NC/1NO)
D4N-@E@@ (1NC/1NO (MBB))
11
One-conduit Type (3 Poles)
A
12
4
(3) 13
14 (4)
(1) 31
32 (2)
3
Pin No. (Terminal No.)
Tolerance ±2 mm
Tolerance ±2 mm
• Do not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
• Use crimp terminals not more than 0.5 mm in thickness. Otherwise,
they will interfere with other components inside the case. The crimp
terminals shown below are not more than 0.5 mm thick.
Manufacture
J.S.T.
Type
FV0.5-3.7 (F type)
V0.5-3.7 (straight type)
J.S.T. is a Japanese manufacturer.
0.5 mm
3.7 mm
2.9 mm
6.6 mm
19 mm D dia.
7.7 mm
8.0 mm
l
F
B
dz dia.
Crimp terminal
Socket Tightening (Connector Type)
• Turn the socket connector screws by hand and tighten until no
space remains between the socket and the plug.
• Make sure that the socket connector is tightened securely.
Otherwise, the rated degree of protection (IP67) may not be
maintained and vibration may loosen the socket connector.
Conduit Opening
L
t:
dz dia.:
D dia.:
B:
L:
F:
I:
• Applicable socket: XS2F (OMRON).
• Refer to the Connector Catalog for details on socket pin numbers
and lead wire colors.
Terminal screw
• Connect a recommended connector to the opening of the conduit
and tighten the connector to the specified torque. The case may be
damaged if an excessive tightening torque is applied.
• When using 1/2-14NPT, wind sealing tape around the joint between
the connector and conduit opening so that the enclosure will
conform to IP67.
• Use a cable with a suitable diameter for the connector.
• Attach and tighten a conduit cap to the unused conduit opening
when wiring. Tighten the conduit cap to the specified torque. The
conduit cap is provided with the Switch (2-conduit types).
Changing the Lever
Correct
Incorrect
The lever mounting screws can be used to set the lever position to
any position in a 360° angle at 7.5° increments. Grooves are incised
on the lever and rotary shaft that engage to prevent the lever from
slipping against the rotary shaft. The screws on adjustable roller
lever models can also loosened to change the length of the lever.
Remove the screws from the front of the lever before mounting the
lever in reverse (front/back), and set the level so that operation will be
completed before exceeding a range of 180° on the horizontal.
Safety Limit Switch D4N
269
Recommended Connectors
Storage
Use connectors with screws not exceeding 9 mm, otherwise the
screws will protrude into the case interior, interfering with other
components in the case. The connectors listed in the following table
have connectors with thread sections not exceeding 9 mm. Use the
recommended connectors to ensure conformance to IP67.
Do not store the Switch in locations where corrosive gases (e.g.,
H2S, SO2, NH3, HNO3, Cl2) or dust is present, or in locations subject
to high temperatures and humidity.
Size
Manufacturer
Model
Applicable cable
diameter
G1/2
LAPP
ST-PF1/2
5380-1002
6.0 to 12.0 mm
Pg13.5
LAPP
ST-13.5
5301-5030
6.0 to 12.0 mm
M20
LAPP
ST-M20 × 1.5
5311-1020
7.0 to 13.0 mm
1/2-14NPT
LAPP
ST-NPT1/2
5301-6030
6.0 to 12.0 mm
Use LAPP connectors together with seal packing (JPK-16, GP-13.5,
GPM20, or GPM12), and tighten to the specified tightening torque.
Seal packing is sold separately.
LAPP is a German manufacturer.
Before using a 2-conduit 1/2-14NPT type, attach the provided
changing adaptor to the Switch and then connect the recommended
connector.
Production Discontinuation
Following the release of the D4N, production of the D4D-N will be
discontinued.
Date of Production Discontinuation
Production of the D4D-N Series will be discontinued as of the end of
March 2006.
Product Replacement
1. Dimensions
The D4D-N and D4N use the same mounting method, and
mounting hole. The multi-contact structure and the extra 4 mm in
length, however, are different.
2. Terminal Numbers
For the 2-contact slow-action model, the terminals 21, 22, 23, and
24 on the D4D-N are 31, 32, 33, and 34 on the D4N.
3. Recommended Terminals
If the recommended terminals are not used, the Switch may not
be compatible. Make sure that the Switch is compatible with the
terminals.
Comparison of the D4D-N and
Substitute Products
Model
D4N
Switch color
Very similar
Dimensions
Very similar
Wiring/connection
Significantly different
Mounting method
Completely compatible
Ratings/performance
Very similar
Operating characteristics
Very similar
Operating method
Completely compatible
270
Safety Limit Switch D4N
Others
• Do not allow the load current to exceed the rated value.
• Confirm that the seal rubber has no defects before use.
If the seal rubber is displaced or raised, or has foreign particles
adhered to it, the sealing capability of the seal rubber will be
adversely affected.
• Use the correct cover mounting screws only, or the sealing
capability of the seal rubber will deteriorate.
• Inspect the Switch regularly.
• Make sure that foreign particles do not enter the head when
removing the screws from the four corners to change the head
position in any of the four directions.
• Use the following recommended countermeasures to prevent
telegraphing when using adjustable or long levers.
1. Make the rear edge of the dog smooth with an angle of 15° to 30°
or make it in the shape of a quadratic curve.
2. Design the circuit so that no error signal will be generated.
3. Use or set a Switch that is operated in one direction only.
Dimensions (Unit: mm)
Discontinued Models (1-conduit Plunger-type D4D-N)
Replacement Products (1-conduit Plunger-type D4N)
25 dia. ±0.1
25±0.1
Two, 3 ±0.05 dia. holes
Two, 3 ±0.05 dia.
holes
12 dia.
12 dia.
6-dia. resin
plunger
6-dia. resin plunger
OP
OP
9±0.2
2.5
2.15±0.05R
mounting holes
55
47±0.2
Two, 4+0.15
dia. holes
0
depth: 5
31 max.
Discontinued Models (2-conduit Plunger-type D4D-N)
(31.5)
21.5
11±0.2
20±0.1
22±0.1
2.15±0.05R
mounting holes
22±0.2
31 max.
Conduit cap
14.2
30
Two, 4+0.15
dia. holes
0
depth: 5
Replacement Products (2-conduit Plunger-type D4N)
25±0.1
Two, 3 ±0.05 dia. holes
depth: 6
Two, 3 ±0.05
dia. holes
12 dia.
12 dia.
6 dia.
6-dia. resin plunger
OP
OP
2.15±0.05R
mounting holes
25 dia.
2.15±0.05R
mounting holes
Cap
56 max.
5.4
Two, 4+0.15
dia. holes
0
depth: 5
(31.5)
21.5
11±0.2
2.5
9±0.2
20±0.1
22±0.1
40±0.1
42±0.1
39±0.2
25 dia.
47
Conduit cap
20.5
Cap
42±0.2
56 max.
(3)
14.2
Two, 4+0.15
dia. holes
30
0
depth: 5
Safety Limit Switch D4N
271
List of Recommended Substitute Products
: The actuator on the D4D-N is a non-safety type. The D4N is recommended for safety applications (form lock type). Be sure to mount it
correctly.
: M screws are recommended to comply with European standards. Therefore, the M20 type is recommended as a substitute when the Pg13.5
conduit-type is not available in a D4N model.
Safety Limit Switches
D4D-N product to be
discontinued
Recommended
substitute product
D4D-N product to be
discontinued
Recommended
substitute product
D4D-N product to be
discontinued
Recommended
substitute product
D4D-1120N
D4N-1120
D4D-1520N
D4N-1A20
D4D-1A20N
D4N-1B20
D4D-2120N
D4N-2120
D4D-2520N
D4N-2A20
D4D-2A20N
D4N-2B20
D4D-3120N
D4N-3120
D4D-3520N
D4N-3A20
D4D-3A20N
D4N-3B20
D4D-5120N
D4N-5120
D4D-5520N
D4N-5A20
D4D-5A20N
D4N-5B20
D4D-6120N
D4N-6120
D4D-6520N
D4N-6A20
D4D-6A20N
D4N-6B20
D4D-1122N
D4N-1122
D4D-1522N
D4N-1A22
D4D-1A22N
D4N-1B22
D4D-2122N
D4N-2122
D4D-2522N
D4N-2A22
D4D-2A22N
D4N-2B22
D4D-3122N
D4N-3122
D4D-3522N
D4N-3A22
D4D-3A22N
D4N-3B22
D4D-5122N
D4N-5122
D4D-5522N
D4N-5A22
D4D-5A22N
D4N-5B22
D4D-6122N
D4N-6122
D4D-6522N
D4N-6A22
D4D-6A22N
D4N-6B22
D4D-1125N
D4N-1125
D4D-1525N
D4N-1A25
D4D-1A25N
D4N-1B25
D4D-2125N
D4N-2125
D4D-2525N
D4N-2A25
D4D-2A25N
D4N-2B25
D4D-3125N
D4N-3125
D4D-3525N
D4N-3A25
D4D-3A25N
D4N-3B25
D4D-1131N
D4N-1131
D4D-1531N
D4N-1A31
D4D-1A31N
D4N-1B31
D4D-2131N
D4N-2131
D4D-2531N
D4N-2A31
D4D-2A31N
D4N-2B31
D4D-3131N
D4N-3131
D4D-3531N
D4N-3A31
D4D-3A31N
D4N-3B31
D4D-5131N
D4N-5131
D4D-5531N
D4N-5A31
D4D-5A31N
D4N-5B31
D4D-6131N
D4N-6131
D4D-6531N
D4N-6A31
D4D-6A31N
D4N-6B31
D4D-1132N
D4N-1132
D4D-1532N
D4N-1A32
D4D-1A32N
D4N-1B32
D4D-2132N
D4N-2132
D4D-2532N
D4N-2A32
D4D-2A32N
D4N-2B32
D4D-3132N
D4N-3132
D4D-3532N
D4N-3A32
D4D-3A32N
D4N-3B32
D4D-5132N
D4N-5132
D4D-5532N
D4N-5A32
D4D-5A32N
D4N-5B32
D4D-6132N
D4N-6132
D4D-6532N
D4N-6A32
D4D-6A32N
D4N-6B32
D4D-1162N
D4N-1162
D4D-1562N
D4N-1A62
D4D-1A62N
D4N-1B62
D4D-2162N
D4N-2162
D4D-2562N
D4N-2A62
D4D-2A62N
D4N-2B62
D4D-3162N
D4N-3162
D4D-3562N
D4N-3A62
D4D-3A62N
D4N-3B62
D4D-5162N
D4N-5162
D4D-5562N
D4N-5A62
D4D-5A62N
D4N-5B62
D4D-6162N
D4N-6162
D4D-6562N
D4N-6A62
D4D-6A62N
D4N-6B62
D4D-1172N
D4N-1172
D4D-1572N
D4N-1A72
D4D-1A72N
D4N-1B72
D4D-2172N
D4N-2172
D4D-2572N
D4N-2A72
D4D-2A72N
D4N-2B72
D4D-3172N
D4N-3172
D4D-3572N
D4N-3A72
D4D-3A72N
D4N-3B72
D4D-5172N
D4N-5172
D4D-5572N
D4N-5A72
D4D-5A72N
D4N-5B72
D4D-6172N
D4N-6172
D4D-6572N
D4N-6A72
D4D-6A72N
D4N-6B72
D4D-112HN
D4N-112H
D4D-152HN
D4N-1A2H
D4D-1A2HN
D4N-1B2H
D4D-212HN
D4N-212H
D4D-252HN
D4N-2A2H
D4D-2A2HN
D4N-2B2H
D4D-312HN
D4N-312H
D4D-352HN
D4N-3A2H
D4D-3A2HN
D4N-3B2H
272
Safety Limit Switch D4N
General-purpose Limit Switches
D4D-N product to be
discontinued
Recommended
substitute product
D4D-N product to be
discontinued
Recommended
substitute product
D4D-N product to be
discontinued
Recommended
substitute product
D4D-1121N
D4N-112G
D4D-15REN
D4N-1ARE
D4D-1AREN
D4N-1BRE
D4D-2121N
D4N-212G
D4D-25REN
D4N-2ARE
D4D-2AREN
D4N-2BRE
D4D-3121N
D4N-312G
D4D-35REN
D4N-3ARE
D4D-3AREN
D4N-3BRE
D4D-5121N
D4N-512G
D4D-55REN
D4N-5ARE
D4D-5AREN
D4N-5BRE
D4D-6121N
D4N-612G
D4D-65REN
D4N-6ARE
D4D-6AREN
D4N-6BRE
D4D-1127N
D4N-112H
D4D-15LEN
D4N-1ALE
D4D-1ALEN
D4N-1BLE
D4D-2127N
D4N-212H
D4D-25LEN
D4N-2ALE
D4D-2ALEN
D4N-2BLE
D4D-3127N
D4N-312H
D4D-35LEN
D4N-3ALE
D4D-3ALEN
D4N-3BLE
D4D-5127N
D4N-512H
D4D-55LEN
D4N-5ALE
D4D-5ALEN
D4N-5BLE
D4D-6127N
D4N-612H
D4D-65LEN
D4N-6ALE
D4D-6ALEN
D4N-6BLE
D4D-1180N
D4N-4180
D4D-1521N
D4N-1A2G
D4D-1A21N
D4N-1B2G
D4D-2180N
D4N-2180
D4D-2521N
D4N-2A2G
D4D-2A21N
D4N-2B2G
D4D-3180N
D4N-3180
D4D-3521N
D4N-3A2G
D4D-3A21N
D4N-3B2G
D4D-5180N
D4N-8180
D4D-5521N
D4N-5A2G
D4D-5A21N
D4N-5B2G
D4D-6180N
D4N-6180
D4D-6521N
D4N-6A2G
D4D-6A21N
D4N-6B2G
D4D-1187N
D4N-4187
D4D-1527N
D4N-1A2H
D4D-1A27N
D4N-1B2H
D4D-2187N
D4N-2187
D4D-2527N
D4N-2A2H
D4D-2A27N
D4N-2B2H
D4D-3187N
D4N-3187
D4D-3527N
D4N-3A2H
D4D-3A27N
D4N-3B2H
D4D-5187N
D4N-8187
D4D-5527N
D4N-5A2H
D4D-5A27N
D4N-5B2H
D4D-6187N
D4N-6187
D4D-6527N
D4N-6A2H
D4D-6A27N
D4N-6B2H
D4D-1A80N
D4N-4B80
D4D-2A80N
D4N-2B80
D4D-3A80N
D4N-3B80
D4D-5A80N
D4N-8B80
D4D-6A80N
D4N-6B80
D4D-1A87N
D4N-4B87
D4D-2A87N
D4N-2B87
D4D-3A87N
D4N-3B87
D4D-5A87N
D4N-8B87
D4D-6A87N
D4N-6B87
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C130-E1-04
In the interest of product improvement, specifications are subject to change without notice.
Safety Limit Switch D4N