Safety-door Switch
D4NS/D4NS-SK
C23I-E-02
Multi-contact, Labor-saving,
Environment-friendly, Nextgeneration Safety-door Switch
• Lineup includes three contact models with 2NC/1NO
and 3NC contact forms and MBB models in addition
to the previous contact forms 1NC/1NO, and 2NC.
• M12-connector models are available, saving on
labor and simplifying replacement.
• Standardized gold-clad contacts provide high
contact reliability.
Applicable to both standard loads and micro-loads.
• Variety of metallic heads available.
• Conforms to ISO 14119.
Slide keys
Be sure to read the “Safety Precautions” on page 13.
Safety Door Switchs
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
Switch (Standard type)
Switch (High pull-force type)
D4NS-@@@
D4NS-@@F-SJ
1 2 3
1. Conduit/Connector size
1:Pg13.5 (1-conduit)
2:G1/2 (1-conduit)
4:M20 (1-conduit)
6:G1/2 (2-conduit)
8:M20 (2-conduit)
9:M12 connector (1-conduit)
1 2
1. Conduit size
2:G1/2 (1-conduit)
4:M20 (1-conduit)
2. Built-in Switch
A:1NC/1NO (slow-action)
B:2NC (slow-action)
C:2NC/1NO (slow-action)
D:3NC (slow-action)
E:1NC/1NO (MBB contact)
F:2NC/1NO (MBB contact)
3. Head Mounting Direction
F:Four mounting directions possible (Front-side mounting at
shipping)/plastic
D:Four mounting directions possible (Front-side mounting at
shipping)/metal
2. Built-in Switch
A:1NC/1NO (slow-action)
B:2NC (slow-action)
C:2NC/1NO (slow-action)
D:3NC (slow-action)
Operation Key
D4DS-K@
1
1. Operation Key Type
1:Horizontal mounting
2:Vertical mounting
3:Adjustable mounting (Horizontal)
5:Adjustable mounting (Horizontal/Vertical)
Note: An order for the head part or the switch part alone cannot be
accepted. (The Operation Key is sold separately.)
1
D4NS/D4NS-SK
Ordering Information
Switches (Operation Keys are sold separately.)
: Models with certified direct opening contacts.
Consult with your OMRON representative when ordering any models that are not listed in this table.
Type
Contact configuration
1NC/1NO
2NC
Slow-action
2NC/1NO
1-Conduit
3NC
1NC/1NO
Slow-action MBB
contact
2NC/1NO
1NC/1NO
2NC
Slow-action
2NC/1NO
2-Conduit
3NC
1NC/1NO
Slow-action MBB
contact
2NC/1NO
1-Conduit, with
connector
Slow-action
Slow-action MBB
contact
Conduit opening/Connector
D4NS-1AF *
G1/2
D4NS-2AF *
M20
D4NS-4AF
Pg13.5
D4NS-1BF *
G1/2
D4NS-2BF *
M20
D4NS-4BF
Pg13.5
D4NS-1CF *
G1/2
D4NS-2CF *
M20
D4NS-4CF
Pg13.5
D4NS-1DF *
G1/2
D4NS-2DF *
M20
D4NS-4DF
Pg13.5
D4NS-1EF
G1/2
D4NS-2EF
M20
D4NS-4EF
Pg13.5
D4NS-1FF
G1/2
D4NS-2FF
M20
D4NS-4FF
G1/2
D4NS-6AF
M20
D4NS-8AF
G1/2
D4NS-6BF
M20
D4NS-8BF
G1/2
D4NS-6CF
M20
D4NS-8CF
G1/2
D4NS-6DF
M20
D4NS-8DF
G1/2
D4NS-6EF
M20
D4NS-8EF
G1/2
D4NS-6FF
M20
D4NS-8FF
D4NS-9AF
1NC/1NO
2NC
M12 connector
1NC/1NO
1NC/1NO
2NC
1-Conduit
Slow-action
(High pull-force type)
2NC/1NO
3NC
Model
Pg13.5
D4NS-9BF
D4NS-9EF
G1/2
D4NS-2AF-SJ *
M20
D4NS-4AF-SJ *
G1/2
D4NS-2BF-SJ *
M20
D4NS-4BF-SJ *
G1/2
D4NS-2CF-SJ *
M20
D4NS-4CF-SJ *
G1/2
D4NS-2DF-SJ *
M20
D4NS-4DF-SJ *
* Models with Korean S-mark certification.
2
D4NS/D4NS-SK
Operation Keys
Type
Model
Horizontal mounting
D4DS-K1
Vertical mounting
D4DS-K2
Adjustable mounting
(Horizontal)
D4DS-K3
Adjustable mounting
(Horizontal/Vertical)
D4DS-K5
Slide Keys
Appearance
Specifications
Contents
Model
Applicable Door
Switch
Weight: 422 g
Slide Key: 1
Mechanical durability: Auxiliary mounting bracket: 1
20,000 operations min. Receptacle bracket: 1
D4NS-SK01
D4NS
1-conduit type
Slide Key: 1
D4NS mounting tool: 1
Inner lever: 1
Weight: 2,800 g
Inner lever mounting screws: 2
Mechanical durability: Door Switch mounting one-way screws: 2
20,000 operations min. Switch protective cover: 1
Switch protective cover screws: 4
Disable-prevention cover
(already mounted on Slide Key): 1
D4NS-SK30
D4NS
1-conduit type
3
D4NS/D4NS-SK
Slide Keys
D4NS-SK01
Configration
Ideal for 20 x 20-mm
aluminum frame doors
D4NS-SK01
D4NS 1-conduit type
Can be mounted directly to a
20 x 20 mm aluminum frame.
Can be mounted directly to a
20 x 20 mm aluminum frame.
1 Release door lock.
4 Lock door.
2 Open door.
3 Close door.
Note: The D4NS-9AF Safety-door Switch
(with M12 connector) is sold separately.
Note: Assess risk before implementing
safety measures for the equipment.
4
D4NS/D4NS-SK
D4NS-SK30
Configration
For safety measures
on large doors
D4NS-SK30
D4NS 1-conduit type
Close door.
Magnetic catches prevent the
operator from accidentally
opening the door.
Open door.
Operation display
window lets you visually
confirm Key insertion.
The handle-shaped fixture makes it easy
to use the Door Switch.
L-shaped key
guard prevents
Key from being
damaged.
Open door.
Set the disableprevention cover
with a pad lock to
prevent an operator
from disabling the
open condition.
ANSI/RIA R15.06-1999 8.4 Protection of personnel within the safeguarded space
Personnel required to perform tasks within the safeguarded space shall be protected by:
a) Preventing the re-initiation of any motion or hazardous process while personnel are within the safeguarded space, for example locking a gate open;
5
D4NS/D4NS-SK
Specifications
Standards and EC Directives
Direct opening travel *4
Conforms to the following EC Directives:
Contact resistance
25 mΩ max.
Machinery Directive
Low Voltage Directive
EN50047
EN60204-1
EN ISO 14119
GS-ET-15
Minimum applicable load *5
1 mA resistive load at 5 VDC (Nlevel reference value)
Rated insulation voltage (Ui)
300 V
Rated frequency
50/60 Hz
Protection against electric
shock
Class II (double insulation)
Certified Standards
Pollution degree (operating
environment)
3 (EN60947-5-1)
Impulse
withstand
voltage
(EN60947-51)
Between
terminals of
same polarity
2.5 kV
Between
terminals of
different
polarity
4 kV
•
•
•
•
•
•
Certification body
Standard
File No.
TÜV SÜD
EN60947-5-1
(certified direct opening)
Consult your
OMRON representative
for details.
UL *1
UL508, CSA C22.2 No.14
E76675
CQC (CCC)
GB14048.5
2003010305077330
KOSHA *2
EN60947-5-1
Consult your
OMRON representative
for details.
Between each 6 kV
terminal and
non-current
carrying
metallic parts
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Utilization
category
Item
AC-15
DC-13
Rated operating current (Ie)
3A
0.27 A
Rated operating voltage (Ue)
240 V
250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the
Switch.
10 mm min.
Insulation resistance
100 MΩ min.
Contact gap
2 × 2 mm min.
Vibration
resistance
Malfunction
10 to 55 Hz, 0.75 mm single
amplitude
Shock
resistance
Destruction
1,000 m/s2 min.
Malfunction
300 m/s2 min.
Conditional short-circuit
current
100 A (EN60947-5-1)
Conventional free air thermal 10 A (EN60947-5-1)
current (Ith)
UL/CSA (UL508, CSA C22.2 No. 14)
Ambient operating
temperature
−30 to 70°C (with no icing)
A300
Ambient operating humidity
95% max.
Weight
Approx. 96 g (D4NS-1CF)
Rated
voltage
120 VAC
240 VAC
Carry current
10 A
Current (A)
Make
Break
60
6
30
3
Volt-amperes (VA)
Make
Break
7,200
720
Q300
Rated
voltage
125 VDC
250 VDC
Carry current
2.5 A
Current (A)
Make
Break
0.55
0.55
0.27
0.27
Volt-amperes (VA)
Make
Break
69
69
Characteristics
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2 Mechanical
1,000,000 operations min.
100,000 operations min.
Electrical
500,000 operations min. (3 A
resistive load at 250 VAC) *3
300,000 operations min. (10 A
resistive load at 250 VAC)
100,000 operations min. (10 A
resistive load at 250 VAC)
Operating speed
0.05 to 0.5 m/s
Direct opening force *4
60 N min.
80 N min.
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads
or microloads. Once the contacts have been used to switch
a load, however, they cannot be used to switch smaller
loads. The contact surfaces will become rough once they
have been used and contact reliability for smaller loads may
be reduced.
*1. The degree of protection is tested using the method specified by
the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment
beforehand. Although the switch box is protected from dust or
water penetration, do not use the D4NS in places where foreign
material may enter through the key hole on the head, otherwise
Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an
ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This value will vary with the switching frequency, environment,
and reliability level. Confirm that correct operation is possible with
the actual load beforehand.
6
D4NS/D4NS-SK
Structure and Nomenclature
Structure
D4NS-@A@, D4NS-@B@, D4NS-@E@,
D4NS-@AF-SJ, D4NS-@BF-SJ
Operation
key hole
D4NS-@C@, D4NS-@D@, D4NS-@F@,
D4NS-@CF-SJ, D4NS-@DF-SJ
Head
The head can be mounted
in four directions.
Sealing properties
The switch casing ensures IP67
Terminal 11
Terminal 12
Terminal 31 (33)
Terminal 32 (34)
Terminal 11
Terminal 12
Terminal 21
Terminal 22
Terminal 31 (33)
Terminal 32 (34)
Note: The 2-conduit models have the same terminal arrangement.
Contact Form
Model
Diagrams Show State with Key Inserted.
Contact
Contact form
11-12
33-34
Zb
D4NS-@A@
D4NS-@AF-SJ
D4NS-@B@
D4NS-@BF-SJ
1NC/1NO
11
12
33
34
11
12
31
32
Zb
D4NS-@C@
D4NS-@CF-SJ
2NC/1NO
11
12
21
22
33
34
Zb
D4NS-@D@
D4NS-@DF-SJ
3NC
11
12
21
22
31
32
D4NS-@E@
1NC/1NO MBB *
11
12
33
34
Zb
D4NS-@F@
2NC/1NO MBB *
Stroke
Extraction
completion
position
Operation
Key insertion
completion
position
Stroke
Operation
Key insertion
completion
position
Extraction
completion
position
11-12
21-22
33-34
ON
Stroke
Extraction
completion
position
Operation
Key insertion
completion
position
11-12
21-22
31-32
ON
Stroke
Operation
Key insertion
completion
position
11
12
21
22
33
34
Stroke
Extraction
completion
position
11-12
21-22
33-34
NC contacts 11-12 and 31-32
have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
NC contacts 11-12 and 21-22
have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
NC contacts 11-12, 21-22, and
31-32 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
Extraction
completion
position
ON
Operation
Key insertion
completion
position
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
ON
11-12
33-34
Zb
Remarks
ON
11-12
31-32
Zb
2NC
Operating pattern
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
ON
NC contacts 11-12 and 21-22
have a certified direct opening
mechanism.
Stroke
Operation
Key insertion
completion
position
Extraction
completion
position
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
* MBB (Make Before Break) contacts have an overlapping structure,
so that before the normally closed contact (NC) opens, the normally
open contact (NO) closes.
7
D4NS/D4NS-SK
Dimensions
(Unit: mm)
Dimensions and Operating Characteristics
1-Conduit Models
Head cap
D4NS-1@F
D4NS-2@F
D4NS-4@F
D4NS-2@F-SJ
D4NS-4@F-SJ
7.5
Model
15.3
Red
Operating
characteristics
30.6
15.5
30.2
Key insertion force
Key extraction force
4.4
41 33.5
2.5
Black
55
47±0.2
D4NS-1@F
D4NS-2@F
D4NS-4@F
21.5
20±0.1
22±0.1
2.15±0.05R
mounting holes
6±3 mm
6±3 mm
Total travel (TT)
(28 mm)
(28 mm)
60 N min.
10 mm min.
80N min.
10mm min.
* Always maintain the above operating characteristics for safe use.
14.2
30
22±0.2
31
15N max.
(50N max.)
Pretravel (PT)
Direct opening force *
Direct opening stroke *
31.5
15 N max.
30 N max.
D4NS-2@F-SJ
D4NS-4@F-SJ
Two, 4+0.15
dia. holes
0
depth: 5
2-Conduit Models
Head cap
D4NS-6@F
D4NS-8@F
7.5
31.5
30.6
42±0.1
40±0.1
30.2
15.3
Red
Model
Operating
characteristics
21.5
15.5
Key insertion force
Key extraction force
4.4
Black
41
47
33.5 5.4
2.5
20.5
20±0.1
39±0.2
9±0.2
Cap (both sides)
42±0.2
56 max.
2.15±0.05R
mounting holes
14.2
3
30
4+0.15
0
Two,
depth: 5
15 N max.
30 N max.
Pretravel (PT)
6±3 mm
Total travel (TT)
(28 mm)
Direct opening force *
Direct opening stroke *
25 dia.
22±0.1
D4NS-6@F
D4NS-8@F
60 N min.
10 mm min.
* Always maintain the above operating characteristics
for safe use.
dia. holes
1-Conduit Connector Models
Head cap
D4NS-9@F
7.5
Red
30.6
15.5
30.2
15.3
Operating
characteristics
Key insertion force
Key extraction force
4.4
Black
Model
D4NS-9@F
15 N max.
30 N max.
41 33.5
Pretravel (PT)
6±3 mm
Total travel (TT)
(28 mm)
2.5
55
47±0.2
21.5
20±0.1
22±0.1
31.5
2.15±0.05R
mounting holes
M12 × 1
Two,
depth: 5
dia. holes
Direct opening force *
Direct opening stroke *
60 N min.
10 mm min.
* Always maintain the above operating characteristics
for safe use.
(14)
22±0.2
31
4+0.15
0
14.2
30
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before
application.
8
D4NS/D4NS-SK
Operation Keys
D4DS-K1
17.5
14
D4DS-K3
28
28
Angle adjustment screw
9 dia.
4
8 dia.
13
4.5 dia.
4.3
7
13
30
15
13
9
6.3
D4DS-K5
6
28
30
56
2
2
10.5
D4DS-K2
40
Black
Four, 2.15R
7
30
20°
20.9
7
15
28
24.6
22.5
4
13
Mounting Holes
(Enlargement)
Angle
adjustment screws
17
13.5
4.5
15
15°
8
30
41
2 4.3
43
55
7
13
Four, 2.15R
41
18°
Black
6.5
18
43
(7)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Slide Keys
D4NS-SK01
Main Body
Auxiliary Mounting Bracket and
Receptacle Bracket
40
20.5
3
12
36.5
Auxiliary mounting bracket
55
19.5
7.5
2
39.5
3
17
13
3
Two, M4 × 6
Receptacle
bracket
Four, M5 tap screws
P=0.8
Stroke
40
70
65
65
58
5.5 dia.
45.5
45.5 60
40
30
45
Switch Mounting Pattern 1
Switch Mounting Pattern 2
74 max.
85
65
3
28
Auxiliary mounting bracket
(included with product)
55
40
39.5
20
45.5
3
42.5
39.5
55
42
Assembled
with D4NS
10
74 max.
3
3
Receptacle bracket
(included with product)
44
(included with
product)
26
58
Assembled
with D4NS Two, M4 × 6
28
40
Stroke
65
70
42
60
60
40
(Stroke)
30
45
51
19.5
30
45
9
D4NS/D4NS-SK
D4NS-SK30
Open Door
(151)
(34)
Brand Name / Model /
Lot No. / Country of Origin
(14.2)
(24)
(237)
Disable-prevention cover
Four, 6.5 × 19 long holes
Trademark
(85)
72
Two, M4
56.5
(40)
66
(27)
(170)
(85)
(168)
72
(58)
(45)
Sliding
17.5
Guide
Two, 6.5 × 19 long holes
Safety Door Switch D4NS
(sold separately)
56.5
66
(35.3)
Shot bolt
17.5 20
(70)
(32)
Lever unit
(117)
8 dia.
(76)
(56.5)
(70)
(75.5)
4
4
25 dia.
Switch part
Handle part
Closed Door
(159)
(R150)
(19)
(78)
8 dia.
(13.7)
(48.5)
(72)
25 dia.
10
D4NS/D4NS-SK
With Operation Key Inserted (Relationship between Insertion Radius and Key Hole)
D4NS-1@F + D4DS-K1
(with Top-inserted Operation Key)
D4NS-1@F + D4DS-K1
(with Front-inserted Operation Key)
Red
44 to 46.5
Key insertion face
(30.6)
Horizontal key insertion
radius R ≥ 200
Red
Horizontal key
insertion radius
R ≥ 200
(15)
(15)
Black
(30.6)
54.5 to 57.0 Key
(41) insertion face
Black
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
Vertical key
insertion radius
R ≥ 200
44 to 46.5
Key insertion face
Vertical key insertion
radius R ≥ 200
(33.5)
(8)
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
54.5 to 57.0 Key
(41) insertion face
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
D4NS-1@F + D4DS-K2
(with Front-inserted Operation Key)
Red
40 to 42.5
Key insertion face
(30.6)
D4NS-1@F + D4DS-K2
(with Top-inserted Operation Key)
Horizontal key
insertion radius
R ≥ 200
Horizontal key insertion
radius R ≥ 200
Red
(15)
(15)
Black
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
50.5 to 53.0 Key
(41) insertion face
Black
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
(30.6)
40 to 42.5
Key insertion face
Vertical key
insertion radius
R ≥ 200
(33.5)
(27.5)
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
Vertical key insertion
radius R ≥ 200
(6)
(8)
50.5 to 53.0 Key
(41) insertion face
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
11
D4NS/D4NS-SK
D4NS-1@F + D4DS-K3
(with Front-inserted Operation Key)
Red
D4NS-1@F + D4DS-K3
(with Top-inserted Operation Key)
45 to 47.5
Key insertion face
(30.6)
40
(40±0.15)
Black
Black
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
(30.6)
45 to 47.5
Key insertion face
Horizontal key insertion
radius R ≥ 50
Red
Horizontal key
insertion radius
R ≥ 50
55.5 to 58.0 Key
insertion face
(41)
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
Vertical key
insertion radius
R ≥ 200
Horizontal key insertion
radius R ≥ 200
(8)
(33.5)
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
55.5 to 58.0 Key
(41) insertion face
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
D4NS-1@F + D4DS-K5
(with Top-inserted Operation Key)
D4NS-1@F + D4DS-K5
(with Front-inserted Operation Key)
Red
51.9 to 54.4
Key insertion face
43 ± 0.1
41 ± 0.1
Red
(30.6)
(43±0.1)
(41±0.1)
Black
62.4 to 64.9 Key
insertion face
Black
Horizontal key
insertion radius
R ≥ 50
(30.6)
51.9 to 54.4
Key insertion face
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
Horizontal key insertion
radius R ≥ 50
(41)
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
Vertical key
insertion radius
R ≥ 50
(33.5)
Permissible difference
in center lines between
the Operation Key and
key hole is ±1.
Horizontal key insertion
radius R ≥ 50
(8)
(41)
62.4 to 64.9 Key
insertion face
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
12
D4NS/D4NS-SK
Safety Precautions
Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
CAUTION
Precautions
for Safe Use
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
Supplementary comments on what to do
or avoid doing, to use the product safely.
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, or undesirable effect on product
performance.
Precautions
for Correct
Use
!CAUTION
Electric shock may occasionally occur.
Do not use metal connectors or metal conduits.
Precautions for Safe Use
• Do not use the Switch submersed in oil or water or in locations
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch. (The IP67 degree of
protection of the Switch specifies the amount of water penetration
after the Switch is submerged in water for a certain period of time.)
• Always attach the cover after completing wiring and before using
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
• Do not switch circuits for two or more standard loads (250 VAC,
3 A). Doing so may adversely affect insulation performance.
Mounting Method
Appropriate Tightening Torque
• Loose screws may result in malfunction. Tighten the screws to the
specified torques.
Terminal screw
0.6 to 0.8 N·m
Cover mounting screw
0.5 to 0.7 N·m
Head mounting screw
0.5 to 0.6 N·m
Operation Key mounting screw
2.4 to 2.8 N·m
Body mounting screw
0.5 to 0.7 N·m
Connector
1.8 to 2.2 N·m
Cap screw
1.3 to 1.7 N·m
• When loosening a screw with an electrical screwdriver or similar
tool while pressing down on the screw head, do not continue
turning the screw past the point where the threads disengage.
Doing so may strip the end of the threads.
Mounting Holes
• Use M4 screws and spring washers to mount the Switch and
Operation Key, and tighten the screws to a suitable torque. To
ensure safety, use screws that cannot be easily removed or
another means to prevent the Switch and Operation Key from
easily being removed.
• As shown below, two studs with a maximum height of 4.8 mm and
a diameter of 4 −0.05
−0.15 mm can be provided, the studs inserted into the
holes on the bottom of the Switch, and the Switch secured at four
locations to increase the mounting strength.
Switch Mounting Holes and Studs Operation Key Mounting Holes
• 1-Conduit Modules
• Horizontal/Vertical Mounting
(D4DS-K1/-K2)
Two, M4
Two, M4
2.5±0.1
20±0.1
22±0.1
Stopper Installation
Do not use a Switch as a stopper. Be sure to install a stopper as
shown in the following illustration to ensure that the base of the
Operation Key does not strike the Head, and adjust the stopper to be
within the setting zone (0.5 to 3 mm) of the base of the Operation Key.
Do not subject the Switch to a shock that exceeds the Switch's shock
resistance of 1,000 m/s2.
Correct
Stopper
15±0.1
47±0.1
Incorrect
• Horizontal Adjustable
Mounting (D4DS-K3)
Two, M4
22±0.1
-0.05
4-0.15 dia.
Height: 4.8 max.
40±0.1
• Horizontal/Vertical Adjustable
Mounting (D4DS-K5)
• 2-Conduit Modules
Two, M4
Two, M4
2.5±0.1
5.35±0.1
39±0.1
41±0.1 or, 43±0.1
20±0.1
22±0.1
40±0.1
42±0.1
Operation key
42±0.1
-0.05
Switch
Precautions for Correct Use
The Switch contacts can be used with either standard loads or
microloads. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The contact
surfaces will become rough once they have been used and contact
reliability for smaller loads may be reduced.
4-0.15 dia.
Height: 4.8 max.
• Set the Operation Key so that it is within 1 mm of the center of the
key hole. If the Operation Key is offset or at an angle, accelerated
wear or breaking may result.
• Observe the specified insertion radius for the Operation Key and
insert it in a direction perpendicular to the key hole.
13
D4NS/D4NS-SK
Head Direction
• The rotation of the Switch head may be adjusted to any of the four
directions by loosening the head mounting screws at the four
corners of the head. Make sure that no foreign materials enter
through the head.
• Do not insert or remove the Operation Key with the Switch head
removed. Doing so may make it impossible to insert the Operation
Key.
The crimp terminals listed below have a thickness of 0.5 mm or less.
Manufacture
Type
FN0.5-3.7 (F Type)
J.S.T. Mfg Co.
N0.5-3.7 (Straight Type)
J.S.T is a Japanese manufacturer.
L
Securing the Door
t:
dz dia.:
D dia.:
B:
L:
F:
I:
When the door is closed (with the Operation Key inserted), the
Operation Key may exceed the set zone because of, for example, the
door's own weight, machine vibration, or the door cushion rubber.
Secure the door with a stopper so that the Operation Key remains
within the set zone.
0.5 mm
3.7 mm
2.9 mm
6.6 mm
19 mm D dia.
7.7 mm
8.0 mm
l
F
B
dz dia.
Terminal screw
Set zone
(0.5 to 3 mm)
Operation Key
Crimp terminal
Wiring
Correct
Wiring
• When connecting with insulation tubes and M3.5 crimp terminals,
connect the terminals as shown in the following figure and wire
without overriding to the case and the cover. Adequate conductor
size is AWG 20 to AWG18 (0.5 to 0.75 mm2).
Prepare lead wires using the lengths given in the following
diagrams. If lead wires are too long, they will press against the
cover causing the cover to not close properly.
Incorrect
Pin arrangement of connector type
1
2
D4NS-9BF (2NC)
4
3
Zb
1 (11)
2 (12)
3 (31)
4 (32)
D4NS-9AF (1NC/1NO)
D4NS-9EF (1NC/1NO (MBB))
Zb
1 (11)
2 (12)
3 (33)
4 (34)
Pin No. (Terminal No.)
• Suitable socket is XS2F-D421 series (OMRON).
• Refer to the Connector Catalog for corresponding Socket pin
numbers and lead wire colors.
1-Conduit Models with 3 Poles
AB
A
11 12
B
C
D
E
C
21 22
D
E
33 34
F
F
42 mm
33 mm
28 mm
Socket Tightening (Models with Connectors)
Tolerance ±2 mm
2-Conduit Models with 3 Poles
ECA
A
11 12
B
Left hand
Right hand
BD F
C
21 22
D
E
33 34
F
BD F
ECA
42 mm
42 mm
28 mm
• Turn the tightening screws on the Socket by hand and tighten them
until the gap between the Socket and Plug essentially disappears.
• Make sure that the Socket’s connector is tightened securely,
otherwise the rated degree of protection (IP67) of the D4NS may
not be maintained, or the Socket connector may be loosened by
vibration.
28 mm
Conduit Opening
Tolerance ±2 mm
Tolerance ±2 mm
• Do not push the crimp terminal and the likes into the opening
between the parts to prevent the case from being broken and
deformed.
• Use terminals having the thickness of 0.5 mm or less to avoid the
contact between the terminal and the Switch case inside.
• Use cables with suitable diameters for the connector being used.
• When wiring, place the enclosed cap screw on unused conduit
openings (for 2-Conduit Switches) and tighten them to the suitable
tightening torque.
Recommended Connectors
Use the connector with thread section of 9 mm long or less. If a
connector with a longer thread section is used, the protruding part
may interfere with the other parts inside the body. Use the connectors
listed below to ensure IP67 degree of protection.
Size
Manufacture
Model
Applicable cable
diameter
G1/2
LAPP
ST-PF1/2
5380-1002
6.0 to 12.0 mm
Pg13.5
LAPP
S-13.5
5301-5030
6.0 to 12.0 mm
M20
LAPP
ST-M20 × 1.5
5311-1020
7.0 to 13.0 mm
When use LAPP's products, use together with a Seal Packing which
is sold separately (Type names, JPK-16, GP-13.5, or GPM20) and
tighten with proper tightening torque.
• LAPP is a German manufacturer.
14
D4NS/D4NS-SK
!CAUTION
• Use the D4NS-SK30 only with the D4NS Safety-door Switch head
in the direction shown below.
Incorrect operation may cause injury. Also, the product is
designed to be mounted so that it slides horizontally.
Do not mount the product in a vertically sliding
configuration.
(excluding the D4NS-SK01)
Precautions for Safe Use
• Do not drop the Switch. Doing so may prevent the Switch from
functioning to full capacity.
• Mount the Switch securely to prevent it from falling. Otherwise,
injuries may occur.
• Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction.
• Make sure that the gap between the short bolt and guide is (±3
mm. Otherwise, excessive wear or damage may cause
malfunction.
• To ensure safety, do not operate the Switch with anything other
than a Slide Key.
• Be careful to avoid pinching your hand when operating the Switch.
• Be sure to mount the Switch protective cover. Otherwise, your
hand may be injured by being pinched between the shot bolt and
Switch when closing the door with your hand on the Switch.
• When opening the door, be sure to lower the disable-prevention
cover into position, attach a padlock, or take other steps to prevent
other people from operating the Switch.
• The durability of the Switch is greatly influenced by the switching
conditions. Always test the Switch under actual working conditions
before application and use it in a switching circuit for which there
are no problems with performance.
• The user must not maintain or repair equipment incorporating the
Switch. Contact the manufacturer of the equipment for any
maintenance or repairs required.
• Do not shut the door while the shot bolt is extended. The Switch
may be damaged, preventing proper operation.
• Do not apply excessive force in the direction of the slide. This may
damage the product and cause it to malfunction.
Precautions for Correct Use
• Insert the slide handle until the red operation indicator is
completely displayed in the operation display window.
Operation Key
Technical Specifications
D4NS-SK30
Ambient operating
temperature
−10 to 55°C (with no icing)
Ambient operating
humidity
95% max.
Mechanical durability
20,000 operations min.
Weight
Approx. 2.8 kg
(not including D4NS Safety-door Switch)
• Do not store the Switch where corrosive gases (e.g., H2S, SO2,
NH3, HNO3, or CL2) or dust are present, or in locations subject to
high temperature or humidity.
• Perform maintenance inspections periodically.
• This product is for use only with OMRON Safety-door Switches.
Do not use it with door switches made by other manufacturers.
Mounting Holes
(Unit: mm)
D4NS-SK30
209.5
131.5
72
72
56.5 66
Six,
M6
45
30
56.5 66
20
Two, R25 (reference)
Assembly
Switch part
D4NS-SK30
Disable-prevention cover
Switch mounting screw
(one-way screw)
Two, M4 × 25
Normal
Insufficient insertion
Operation display window
• Loose screws may result in malfunction. Use washers and tighten
the screws to the specified torques. Also, when mounting the
Switch to a door for disable-prevention purposes, purchase and
use tamper-resistant screws.
Switch protective cover
mounting screw
Four, M4 × 6
Guide
Handle part
Tightening Torque
Slide Key mounting screw (M6)
6.0 to 7.0 N·m
Switch mounting screw
(included with product)
0.5 to 0.7 N·m
Switch protective cover
mounting screw (included with
product)
1.2 to 1.4 N·m
Lever mounting screw
(included with product)
1.2 to 1.4 N·m
D4NS-SK30
If a burden is placed on the short bolt or guide, making
the door difficult to open and close, adjust the mounting
position within the range of the long holes.
Short bolt
Lever mounting screw
Two, M4 × 8
15
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
14.
15.
16.
17.
18.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for published information.
Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2.
3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu
Authorized Distributor:
Automation Control Systems
• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches
C23I-E-02
07/15
Note: Specifications are subject to change.
Printed on recycled paper.
© 2015 Omron Electronics LLC
Printed in U.S.A.