NEW
Guard Lock
Safety-door Switch
D4SL
Strong
World
Smallest
Class
Easy
Connector Type
Terminal Block Type
GUARD LOCK SAFETY-DOOR SWITCH
Strong
Easy
World Smallest
Class 6-contact
Guard Lock
Safety-door Switch
Achieved world smallest class
with easily selectable wiring
method and metal-head
robustness
Easy
Conveniently Selectable Wiring Method
Two types of wiring methods are available to shorten wiring work time and prevent miswiring. Use of
the "connector type" with the corresponding connector cable provides speedy maintenance and
prevents miswiring. The "terminal block type" comprises a detachable terminal block, significantly
increasing wiring efficiency.
Connector Type
Terminal Block Type
Detachable
terminal
block
* Connector cables are not included with the connector type
and are to be purchased separately.
1
Cable break
Easy
replacement
in case of
cable break
2
3
Remove the
cable.
Remove
Replace with a new
cable, and resume
production without
delay.
NEW
(Connector type)
Strong
Adopting Metal Head
The head is designed with strong and durable materials,
able to withstand prolonged use in the workplace.
Metal
Head
To prepare for any unforeseeable circumstances,
a key holding force of 1,300 N (min.) has been
achieved. This has increased the range of
possible applications.
1,300N
Wide Key Slot
Even when the door is unstable, the wide key slot provides easier insertion than prior models.
D4GL
D4SL
(Precedent
model)
Actual size
Actual size
3
Easy
Wide Variety of Mounting Methods
The switch can be mounted in four directions by rotating the
dedicated spacer. Mounting screws can be inserted
4-directionally, enabling mounting on a wider range of surfaces.
Thus saving time and effort over the prior mounting method.
Front mounting
Pull out
4-directional
mounting
Side mounting*
Rotate 90°
* Three screws are needed for side
mounting.
Easy View LED Indicators
With the two LED indicators, switch status can be checked
from any direction.
Safe
Merits of 6-contact Models
The safety circuit comprises of four contacts and of two contacts used for monitoring.
Door open/closed status and lock status can be monitored.
Pattern 1
Lock Monitor
Door
closed
Door
open
Door Open/Closed Detection
42
41 12
11
52
51 22
21
64
63 34
33
Monitors the
door's lock state.
Monitors if the door is open.
Pattern 2
Lock
ON
Lock
OFF
Monitors if the door lock is released.
4
Lock
ON
Monitors the door's
open/closed state.
Strong
Safer
Safe
Wide Variety of Operation Keys
Within the selection are keys with shock and vibration resistant properties and a single adjustable type.
Horizontal mounting
D4SL-K1
Horizontal mounting (Short)
D4SL-K1S
Horizontal mounting (with Cushion Rubber)
D4SL-K1G
Vertically mounting
D4SL-K2
Vertical mounting (with Cushion Rubber)
D4SL-K2G
Adjustable (Horizontal)
D4SL-K3
Accessories for Room Access Control
Door mounting accessories for D4SL are provided to prevent an operator becoming trapped inside the
hazardous area by using a lockout key. In combination with A22TK, a safe environment can be kept during
maintenance inside the hazardous area.
D4SL-SK10-LK
D4SL
A22TK
5
Guard Lock Safety-door Switch
D4SL
World’s Smallest Class 6-contact Guard Lock
Safety-door Switch
• Two types are available: a connector type that reduces wiring time and a
detachable terminal block type.
• Robust and durable metal head.
• Key holding force of 1,300 N.
• The wider key slot is less susceptible to movement from doors, and can
handle doors with a small radius.
• By rotating the mounting part, it is possible, both to change the key insertion
point and to enable mounting on various devices.
• Easy view LED indicators can be checked from any direction.
• By utilizing the 6-contact type, both the door open/closed status and the
solenoid ON/OFF status can be monitored independently.
• A cost-effective 5-contact model is also available.
Connector Type
Terminal Block Type
Be sure to read the “Safety Precautions”
on page 24.
Model Number Structure
Model Number Legend
Switch
D4SL-@@@@-@@@
–––– –––
1 2 3 4
5 6 7
1. Conduit Size
2 : G1/2 (1 conduit)
3 : 1/2-14NPT (1 conduit) *1
4 : M20 (1 conduit)
2. Built-in Switch *2
5-contact Model
J : 1NC/1NO + 2NC/1NO
K : 1NC/1NO + 3NC
L : 2NC + 2NC/1NO
M : 2NC + 3NC
6-contact Model
N : 2NC/1NO + 2NC/1NO
P : 2NC/1NO + 3NC
Q : 3NC + 2NC/1NO
R : 3NC + 3NC
3. Head Material
D : Metal
4. Door Lock and Release
A : Mechanical lock/
24 VDC solenoid release
G : 24 VDC solenoid lock/
mechanical release
7. Connection Method
Blank : Terminal block
N : Connector *3
5. Indicator
D : 24 VDC (orange LED indicator)
6. Release Key Type
Blank : Standard release key
4 : Special release key
(Note: Release keys are provided.)
*1. M20, includes M20-to-1/2-14NPT conversion adapter (To be released.)
*2. If a current is detected in the solenoid lock model (built-in switches; N,P,Q,R), before the door is closed, the door will remain unlocked.
Be sure to close the door before turning ON the solenoid.
*3. Connector cables are not included with the connector type and are to be purchased separately.
Operation Key
D4SL-K@@
––
1 2
1. Operation Key Type
1 : Horizontal mounting
2 : Vertical mounting
3 : Adjustable mounting (horizontal)
6
2. Key Type
Blank : No cushion rubber
G : Cushion rubber
S : No cushion rubber, short type
D4SL
Ordering Information
Mechanical lock/24 VDC solenoid release (G1/2, M20 conduit type)
List of Models (Operation Keys are sold separately.)
Release
key type
Wiring
method
Solenoid
voltage/
Indicator
Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
Connector
3NC + 2NC/1NO
3NC + 3NC
Standard
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
Terminal
block
3NC + 2NC/1NO
24 VDC
Orange
Mechanical
lock
Solenoid
release
3NC + 3NC
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
Connector
3NC + 2NC/1NO
3NC + 3NC
Special
release
key
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
Terminal
block
3NC + 2NC/1NO
3NC + 3NC
Conduit size
Model
G1/2
D4SL-2NDA-DN
M20
D4SL-4NDA-DN
G1/2
D4SL-2PDA-DN
M20
D4SL-4PDA-DN
G1/2
D4SL-2QDA-DN
M20
D4SL-4QDA-DN
G1/2
D4SL-2RDA-DN
M20
D4SL-4RDA-DN
G1/2
D4SL-2NDA-D
M20
D4SL-4NDA-D
G1/2
D4SL-2PDA-D
M20
D4SL-4PDA-D
G1/2
D4SL-2QDA-D
M20
D4SL-4QDA-D
G1/2
D4SL-2RDA-D
M20
D4SL-4RDA-D
G1/2
D4SL-2NDA-D4N *
M20
D4SL-4NDA-D4N *
G1/2
D4SL-2PDA-D4N *
M20
D4SL-4PDA-D4N *
G1/2
D4SL-2QDA-D4N *
M20
D4SL-4QDA-D4N *
G1/2
D4SL-2RDA-D4N *
M20
D4SL-4RDA-D4N *
G1/2
D4SL-2NDA-D4
M20
D4SL-4NDA-D4
*
G1/2
D4SL-2PDA-D4
*
M20
D4SL-4PDA-D4
*
G1/2
D4SL-2QDA-D4
*
*
M20
D4SL-4QDA-D4
*
G1/2
D4SL-2RDA-D4
*
M20
D4SL-4RDA-D4 *
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
* These models received Korean S-mark certification.
7
D4SL
24 VDC solenoid lock/Mechanical release (G1/2, M20 conduit type)
List of Models (Operation Keys are sold separately.)
Release
key type
Wiring
method
Solenoid
voltage/
Indicator
Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
1NC/1NO + 2NC/1NO
1NC/1NO + 3NC
2NC + 2NC/1NO
2NC + 3NC
Connector
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
3NC + 2NC/1NO
24 VDC
Orange
Standard
Solenoid lock/
Mechanical
release
3NC + 3NC
1NC/1NO + 2NC/1NO
1NC/1NO + 3NC
2NC + 2NC/1NO
2NC + 3NC
Terminal
block
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
3NC + 2NC/1NO
3NC + 3NC
Conduit size
Model
G1/2
D4SL-2JDG-DN
M20
D4SL-4JDG-DN
G1/2
D4SL-2KDG-DN
M20
D4SL-4KDG-DN
G1/2
D4SL-2LDG-DN
M20
D4SL-4LDG-DN
G1/2
D4SL-2MDG-DN
M20
D4SL-4MDG-DN
G1/2
D4SL-2NDG-DN
M20
D4SL-4NDG-DN
G1/2
D4SL-2PDG-DN
M20
D4SL-4PDG-DN
G1/2
D4SL-2QDG-DN
M20
D4SL-4QDG-DN
G1/2
D4SL-2RDG-DN
M20
D4SL-4RDG-DN
G1/2
D4SL-2JDG-D
M20
D4SL-4JDG-D
G1/2
D4SL-2KDG-D
M20
D4SL-4KDG-D
G1/2
D4SL-2LDG-D
M20
D4SL-4LDG-D
G1/2
D4SL-2MDG-D
M20
D4SL-4MDG-D
G1/2
D4SL-2NDG-D
M20
D4SL-4NDG-D
G1/2
D4SL-2PDG-D
M20
D4SL-4PDG-D
G1/2
D4SL-2QDG-D
M20
D4SL-4QDG-D
G1/2
D4SL-2RDG-D
M20
D4SL-4RDG-D
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
8
D4SL
24 VDC solenoid lock/Mechanical release (G1/2, M20 conduit type)
List of Models (Operation Keys are sold separately.)
Release
key type
Wiring
method
Solenoid
voltage/
Indicator
Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
1NC/1NO + 2NC/1NO
1NC/1NO + 3NC
2NC + 2NC/1NO
2NC + 3NC
Connector
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
3NC + 2NC/1NO
Special
release
key
24 VDC
Orange
Solenoid lock/
Mechanical
release
3NC + 3NC
1NC/1NO + 2NC/1NO
1NC/1NO + 3NC
2NC + 2NC/1NO
2NC + 3NC
Terminal
block
2NC/1NO + 2NC/1NO
2NC/1NO + 3NC
3NC + 2NC/1NO
3NC + 3NC
Conduit size
Model
G1/2
D4SL-2JDG-D4N
M20
D4SL-4JDG-D4N
G1/2
D4SL-2KDG-D4N
M20
D4SL-4KDG-D4N
G1/2
D4SL-2LDG-D4N
M20
D4SL-4LDG-D4N
G1/2
D4SL-2MDG-D4N
M20
D4SL-4MDG-D4N
G1/2
D4SL-2NDG-D4N *
M20
D4SL-4NDG-D4N *
G1/2
D4SL-2PDG-D4N *
M20
D4SL-4PDG-D4N *
G1/2
D4SL-2QDG-D4N *
M20
D4SL-4QDG-D4N *
G1/2
D4SL-2RDG-D4N *
M20
D4SL-4RDG-D4N *
G1/2
D4SL-2JDG-D4
M20
D4SL-4JDG-D4
G1/2
D4SL-2KDG-D4
M20
D4SL-4KDG-D4
G1/2
D4SL-2LDG-D4
M20
D4SL-4LDG-D4
G1/2
D4SL-2MDG-D4
M20
D4SL-4MDG-D4
G1/2
D4SL-2NDG-D4
*
M20
D4SL-4NDG-D4
*
G1/2
D4SL-2PDG-D4
*
M20
D4SL-4PDG-D4
*
G1/2
D4SL-2QDG-D4
*
M20
D4SL-4QDG-D4
*
G1/2
D4SL-2RDG-D4
*
M20
D4SL-4RDG-D4 *
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
* These models received Korean S-mark certification.
9
D4SL
Mechanical lock/24 VDC solenoid release (1/2-14NPT conduit type)
List of Models (Operation Keys are sold separately.)
Contact configuration
Model
(door open/closed detection switch Conduit size
(Available soon)
and lock monitor switch contacts)
2NC/1NO + 2NC/1NO
D4SL-3NDA-DN
2NC/1NO + 3NC
D4SL-3PDA-DN
Connector
3NC + 2NC/1NO
D4SL-3QDA-DN
3NC + 3NC
D4SL-3RDA-DN
Standard
2NC/1NO + 2NC/1NO
D4SL-3NDA-D
2NC/1NO + 3NC
D4SL-3PDA-D
Terminal
block
3NC
+
2NC/1NO
D4SL-3QDA-D
Mechanical
3NC + 3NC
D4SL-3RDA-D
24 VDC
lock
1/2-14NPT
Orange
Solenoid
2NC/1NO + 2NC/1NO
D4SL-3NDA-D4N *
release
2NC/1NO + 3NC
D4SL-3PDA-D4N *
Connector
3NC + 2NC/1NO
D4SL-3QDA-D4N *
Special
3NC + 3NC
D4SL-3RDA-D4N *
release
2NC/1NO + 2NC/1NO
D4SL-3NDA-D4 *
key
2NC/1NO + 3NC
D4SL-3PDA-D4 *
Terminal
block
3NC + 2NC/1NO
D4SL-3QDA-D4 *
3NC + 3NC
D4SL-3RDA-D4 *
Note: The recommended models for equipment and machinery being exported to North America are those with a 1/2-14NPT conduit sizes.
* These models will receive Korean S-mark certification.
Release
key type
Wiring
method
Solenoid
voltage/
Indicator
Lock and
release type
24 VDC solenoid lock/Mechanical release (1/2-14NPT conduit type)
List of Models (Operation Keys are sold separately.)
Contact configuration
Model
(door open/closed detection switch Conduit size
(Available soon)
and lock monitor switch contacts)
1NC/1NO + 2NC/1NO
D4SL-3JDG-DN
1NC/1NO + 3NC
D4SL-3KDG-DN
2NC + 2NC/1NO
D4SL-3LDG-DN
2NC + 3NC
D4SL-3MDG-DN
Connector
2NC/1NO + 2NC/1NO
D4SL-3NDG-DN
2NC/1NO + 3NC
D4SL-3PDG-DN
3NC + 2NC/1NO
D4SL-3QDG-DN
3NC + 3NC
D4SL-3RDG-DN
24 VDC
Standard
Orange
1NC/1NO + 2NC/1NO
D4SL-3JDG-D
1NC/1NO + 3NC
D4SL-3KDG-D
2NC + 2NC/1NO
D4SL-3LDG-D
2NC + 3NC
D4SL-3MDG-D
Terminal
block
2NC/1NO + 2NC/1NO
D4SL-3NDG-D
2NC/1NO + 3NC
D4SL-3PDG-D
3NC + 2NC/1NO
D4SL-3QDG-D
Solenoid lock/
3NC + 3NC
D4SL-3RDG-D
Mechanical
1/2-14NPT
1NC/1NO
+
2NC/1NO
D4SL-3JDG-D4N
release
1NC/1NO + 3NC
D4SL-3KDG-D4N
2NC + 2NC/1NO
D4SL-3LDG-D4N
2NC + 3NC
D4SL-3MDG-D4N
Connector
2NC/1NO + 2NC/1NO
D4SL-3NDG-D4N
2NC/1NO + 3NC
D4SL-3PDG-D4N
3NC + 2NC/1NO
D4SL-3QDG-D4N
Special
3NC + 3NC
D4SL-3RDG-D4N
24 VDC
release
Orange
1NC/1NO
+
2NC/1NO
D4SL-3JDG-D4
key
1NC/1NO + 3NC
D4SL-3KDG-D4
2NC + 2NC/1NO
D4SL-3LDG-D4
2NC + 3NC
D4SL-3MDG-D4
Terminal
block
2NC/1NO + 2NC/1NO
D4SL-3NDG-D4
2NC/1NO + 3NC
D4SL-3PDG-D4
3NC + 2NC/1NO
D4SL-3QDG-D4
3NC + 3NC
D4SL-3RDG-D4
* The recommended models for equipment and machinery being exported to North America are those with a 1/2-14NPT conduit sizes.
* These models will receive Korean S-mark certification.
Release
key type
10
Wiring
method
Solenoid
voltage/
Indicator
Lock and
release type
*
*
*
*
*
*
*
*
D4SL
Operation Keys
Connector Cables
Type
Horizontal mounting
Model
D4SL-K1
Horizontal mounting
(Short)
D4SL-K1S
Horizontal mounting
(Cushion rubber)
D4SL-K1G
Vertical mounting
D4SL-K2
Horizontal mounting
(Cushion rubber)
D4SL-K2G
Adjustable (Horizontal)
D4SL-K3
Type
Model
1m
D4SL-CN1
3m
D4SL-CN3
5m
D4SL-CN5
Slide Key
Type
Model
D4SL-SK10-LK
11
D4SL
Specifications
Characteristics
Standards and EC Directives
Degree of protection *1
Conforms to the following EC Directives:
•
•
•
•
•
•
Machinery Directive
Low Voltage Directive
EMC Directive
EN1088
EN60204-1
GS-ET-19
Durability
*2
Certified Standards
Certification body
Standard
File No.
Consult your
OMRON
representative for
details.
TÜV SÜD
EN60947-5-1
(certified direct opening)
UL *
UL508, CSA C22.2 No.14 E76675
CQC(CCC)
GB14048.5
pending
Consult your
OMRON
KOSHA
EN60947-5-1
representative for
details.
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Item
Utilization category
AC-15
DC-13
1.5A
0.22A
Rated operating current (Ie)
0.05 to 1 m/s
5 operations minute max.
Direct opening force *4
60 N min. (EN60947-5-1)
Direct opening travel *4
15 mm min. (EN60947-5-1)
Holding force *5
1,300 N min.
Contact resistance
200 mΩ max.
Minimum applicable load 1 mA resistive load at 5 VDC
*6
(N-level reference value)
Rated insulation voltage (Ui)
150V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against
electric shock
Class II (double insulation)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Impulse
withstand
voltage
(EN60947-5-1)
120 VAC
Carry
current
2.5A
Volt-amperes
(VA)
Current (A)
Make
15
Break
1.5
Make
1,800
Break
180
R150
Rated
voltage
Carry
current
125 VDC
1.0A
Volt-amperes
(VA)
Current (A)
Make
Break
Make
Break
0.22
0.22
28
28
Vibration
resistance
Shock
resistance
Solenoid Coil Characteristics
Type
24 VDC
Rated operating voltage
(100% ED)
24 VDC
Current consumption *
Power ON: Approx. 34 W at 1.4 A
Constant: Approx. 2.6 W (average) at
0.4 A (max.)
+10%
-15%
Insulation
Class E (120°C max.)
* A starting current is applied to the solenoid for a maximum of one
second.
After this, the internal circuit switches to a constant current.
Indicator
Item
12
Type
1.5 kV
Between
terminals of
different
polarity
1.5 kV
Between other
terminals and
non-current
carrying
metallic parts
2.5 kV
LED type
Rated voltage
24 VDC
Current consumption
Approx. 10 mA
Color (LED)
Orange
100 Ω min. (at 500 VDC)
Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Malfunction 100 m/s2 min.
Destruction 1,000 m/s2 min.
Conditional short-circuit
100 A (EN60947-5-1)
current
Conventional free air
thermal current (Ith)
2.5 A (EN60947-5-1)
Ambient operating
temperature
-10 to 55°C (with no icing)
Ambient operations humidity 95% max.
Weight
Item
Between
terminals of
same polarity
Insulation resistance
UL/CSA (UL508, CSA C22.2 No. 14)
C150
150,000 operations min.
(1A resistance at 125VAC) *3
Operating frequency
Rated operating current (Ue)
120V
125V
Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit
protection device. This fuse is not included with the switch.
Rated
voltage
Electrical
Operating speed
Certified Standard Ratings
TÜV(EN60947-5-1)
IP67 (EN60947-5-1)
Mechanical 1,000,000 operations min.
Approx. 360 g (Connector model)
Approx. 390 g (Terminal block model)
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads
or microloads. Once the contacts have been used to switch
a load, however, they cannot be used to switch smaller
loads.
The contact surfaces will become rough once they have
been used and contact reliability for smaller loads may be
reduced.
*1. The degree of protection is tested using the method specified by
the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment
beforehand.
Although the switch box is protected from dust, oil or water
penetration, do not use the D4SL in places where cutting chips,
oil, water or chemicals may enter through the key hole on the
head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an
ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
*3. Do not pass the 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment,
and reliability level. Confirm that correct operation is possible with
the actual load beforehand.
D4SL
Connections
Internal Circuit Diagram
24 VDC
E1(+)
Connection Example for D4SL-@MDG
• Terminals 12-41 are connected internally and so connect terminals
11-42 for safety-circuit input. (BIA GS-ET-19)
D
R
Control
ZD
LED
9
E1
(+)
10
E2
(-)
D
circuit
E2(-)
Circuit Connection Example
• Direct opening contacts used as safety-circuit input are indicated
with the
mark.
• Do not switch circuits for three or more standard loads at the same
time.
Doing so may adversely affect insulation performance.
• DC solenoids have polarity. (E1: Positive, E2: Negative)
Confirm terminal polarity before wiring.
Connection Example for D4SL-@JDG
• Terminals 12-41 are connected internally and so connect terminals
11-42 for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
42
6
52
8
64
Lock monitor
switch
41
12
63
34
7
4
11
1
To safety circuit
51
5
To control circuit
33
3
To control circuit
To control circuit
2
42
6
52
8
61
Lock monitor
switch
41
12
62
32
7
4
11
1
To safety circuit
51
5
To control circuit
31
3
To control circuit
To control circuit
Connection Example for D4SL-@NDA and D4SL-@NDG
• Terminals 12- 41, and 22- 51 are connected internally and so
connect terminals 11-42, and 21-52 for safety-circuit input. (BIA
GS-ET-19)
9
E1
(+)
10
E2
(-)
Door open/closed
detection switch
LED
Door open/
closed detection
switch
LED
Door open/
closed detection
switch
LED
2
42
41
12
11
1
To safety circuit
4
52
51
22
21
3
To safety circuit
8
64
63
34
33
5
To control circuit
7
6
Lock monitor
switch
To control circuit
Connection Example for D4SL-@PDA and D4SL-@PDG
• Terminals 12-41, and 22-51 are connected internally and so
connect terminals 11-42, and 21-52 for safety-circuit input. (BIA
GS-ET-19)
Connection Example for D4SL-@KDG
• Terminals 12-41 are connected internally and so connect terminals
11-42 for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
Door open/
closed detection
switch
E2
(-)
2
42
6
52
8
61
41
12
11
1
Door open/closed
detection switch
LED
E1
(+)
LED
10
9
2
42
41
12
11
1
To safety circuit
4
52
51
22
21
3
To safety circuit
8
62
61
34
33
5
To control circuit
7
6
To safety circuit
51
5
To control circuit
33
3
To control circuit
Lock monitor
switch
To control circuit
Lock monitor
switch
62
34
7
4
Connection Example for D4SL-@QDA and D4SL-@QDG
To control circuit
Connection Example for D4SL-@LDG
• Terminals 12-41 are connected internally and so connect terminals
11-42 for safety-circuit input. (BIA GS-ET-19)
• Terminals 12-41, and 22-51 are connected internally and so
connect terminals 11-42, and 21-52 for safety-circuit input. (BIA
GS-ET-19)
9
E1
(+)
10
E2
(-)
Door open/closed
detection switch
LED
9
E1
(+)
10
E2
(-)
Door open/
closed detection
switch
LED
2
42
6
52
8
64
Lock monitor
switch
41
12
63
32
7
4
11
1
To safety circuit
51
5
To control circuit
31
3
42
41
12
11
1
To safety circuit
4
52
51
22
21
3
To safety circuit
8
64
63
32
31
5
To control circuit
7
6
Lock monitor
switch
To control circuit
To control circuit
2
To control circuit
Connection Example for D4SL-@RDA and D4SL-@RDG
• Terminals 12-41, and 22-51 are connected internally and so
connect terminals 11-42, and 21-52 for safety-circuit input. (BIA
GS-ET-19)
9
E1
(+)
10
E2
(-)
Door open/closed
detection switch
LED
2
42
41
12
11
1
To safety circuit
4
52
51
22
21
3
To safety circuit
8
62
61
32
31
5
To control circuit
7
6
Lock monitor
switch
To control circuit
13
D4SL
Structure and Nomenclature
Structure
D4SL-@@D@-D4N Connector Model
D4SL-@@D@-D4 Terminal Block Model
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
Can be mounted
from four directions.
The switch has an
indicator on the back
of the switch as well.
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
D4SL-@NDA and D4SL-@NDG
9
E1(+)
10 E2(-)
Can be mounted
from four directions.
The switch has an
indicator on the back
of the switch as well.
ORANGE
2
42
41
12
11
1
4
52
51
22
21
3
8
64
63
34
33
5
7
6
Note: Numbers inside the boxes are terminal
numbers printed on the product.
D4SL-@JDG
9
E1(+)
10 E2(-)
12
11
1
63
34
33
3
7
4
42
41
6
52
51 5
8
64
2
ORANGE
Note: Numbers inside the boxes are terminal
numbers printed on the product.
14
D4SL
Contact Form
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41, 51 and 22 are connected internally (as per BIA GSET-19).
Model
Contact Form
Contact
(door open/
Door open/
closed detection
Lock monitor
closed
and lock monitor)
detection
Operating pattern
Remarks
Lock position
Lock monitor
D4SL@JD@-D@@
1NC/1NO +
2NC/1NO
42
Door open/closed
detection
41 12
11
52
51
64
63 34
33
42-11
34-33
52-51
64-63
Only NC contact 11-12 has a certified direct opening mechanism.
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@KD@-D@@
42
Door open/closed
detection
41 12
11
52
51
1NC/1NO + 3NC
62
61 34
33
42-11
34-33
52-51
62-61
Only NC contact 11-12 has a certified direct opening mechanism.
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@LD@-D@@
42
Door open/closed
detection
41 12
11
52
51
64
63 32
2NC + 2NC/1NO
31
42-11
32-31
52-51
64-63
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@MD@-D@@
42
Door open/closed
detection
41 12
11
52
51
62
61 32
2NC + 3NC
31
42-11
32-31
52-51
62-61
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@ND@-D@@
2NC/1NO +
2NC/1NO
42
Door open/closed
detection
41 12
11
52
51 22
21
64
63 34
33
42-11
52-21
34-33
64-63
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@PD@-D@@
42
Door open/closed
detection
41 12
11
52
51 22
21
62
61 34
33
2NC/1NO + 3NC
42-11
52-21
34-33
62-61
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@QD@-D@@
42
Door open/closed
detection
41 12
11
52
51 22
21
64
63 32
31
3NC + 2NC/1NO
42-11
52-21
32-31
64-63
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
Lock position
Lock monitor
D4SL@RD@-D@@
42
Door open/closed
detection
41 12
11
52
51 22
21
62
61 32
31
3NC + 3NC
The terminals 42-11, 33-34, 5152, and 64-63 can be used as unlike poles.
42-11
52-21
32-31
62-61
ON
Stroke
Operation Key insertion
completion position
Extraction completion
position
The terminals 42-11, 33-34, 5152, and 62-61 can be used as unlike poles.
Only NC contacts 11-12 and 3132 have a certified direct opening
mechanism.
The terminals 42-11, 33-34, 5152, and 64-63 can be used as unlike poles.
Only NC contacts 11-12 and 3132 have a certified direct opening
mechanism.
The terminals 42-11, 33-34, 5152, and 62-61 can be used as unlike poles.
Only NC contacts 11-12 and 2122 have a certified direct opening
mechanism.
The terminals 42-11, 52-21, 3433, and 64-63 can be used as unlike poles.
Only NC contacts 11-12 and 2122 have a certified direct opening
mechanism.
The terminals 42-11, 52-21, 3433, and 62-61 can be used as unlike poles.
Only NC contacts 11-12, 21-22,
and 31-32 have a certified direct
opening mechanism.
The terminals 42-11, 52-21, 3231, and 64-63 can be used as unlike poles.
Only NC contacts 11-12, 21-22,
and 31-32 have a certified direct
opening mechanism.
The terminals 42-11, 52-21, 3231, and 62-61 can be used as unlike poles.
15
D4SL
Structure
D4SL-@@D@-D4N Connector Model
D4SL-@@D@-D4 Terminal Block Model D4SL-@NDA and D4SL-@NDG
9
E1(+)
10 E2(-)
ORANGE
2
42
41
12
11
1
4
52
51
22
21
3
8
64
63
34
33
5
7
6
Note: Numbers inside the boxes indicate
terminal numbers printed on the product.
1
2
3
4
5
6
D4SL-@JDG
10
9
Notched side is No. 1
1
2
3
4
5
6
7
E1(+)
9
8 10
10 E2(-)
12
11
1
63
34
33
3
7
4
42
41
6
52
51 5
8
64
2
ORANGE
Note: Numbers inside the boxes indicate
terminal numbers printed on the product.
Operating Cycle Examples for Standard Models
D4SL-@@DA-D4@ (Mechanical Lock Models with Special Release Keys)
Door condition
Condition 1
Condition 2
Turning the special
release key
Condition 3
Return to
condition 1
Terminal No. and function
E1-E2
Door open.
The door will lock when
the door closes.
Door closed.
The door is locked.
Door closed.
The door can be opened.
Door closed.
No power is supplied to the solenoid.
The door is unlocked manually.
Solenoid ON
42-11 (NC) Door open/closed detection
52-21 (NC) and lock monitor contacts
31-32 (NC)
Door open/closed
detection contact
33-34 (NO)
Door open/closed
detection contact
51-52 (NC) Lock monitor
61-62 (NC) contact
63-64 (NO)
Lock monitor
contact
D4SL-@@DG-D4@ (Solenoid Lock Models with Special Release Keys)
Door condition Even when the door is closed,
it does not lock until power is
Terminal No. and function supplied to the solenoid.
E1-E2
Door closed.
The door is locked.
Door closed.
The door can be opened.
Solenoid ON
42-11 (NC) Door open/closed detection
52-21 (NC) and lock monitor contacts
31-32 (NC)
Door open/closed
detection contact
33-34 (NO)
Door open/closed
detection contact
51-52 (NC) Lock monitor
61-62 (NC) contact
63-64 (NO)
Lock monitor
contact
The shaded areas indicate the contact is closed and power is supplied to the solenoid.
Door open/closed detection and lock monitor contacts : Can be used in safety circuits because of the direct opening mechanisms.
Door open/closed detection contact
: Can be used to confirm whether the key is inserted and to monitor the open/closed status of a door.
Lock monitor contact
: Can be used to confirm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed.
Note: 1. The door open/closed detection and lock monitor contact configuration depends on the model.
2. If a current is detected in the solenoid lock model (built-in switches; N,P,Q,R), before the door is closed, the door will remain unlocked.
Be sure to supply power to the solenoid after the door is closed.
16
D4SL
Dimensions and Operating Characteristics
(unit: mm)
Switches
D4SL-@@D@-D4N
Head cap
29.2
29.2
9
Pre-travel distance
39
37
22±0.2
Operation Key
26.3
A
Front-side mounting
2, 4.3 dia.
Mounting hole
26.3
Spacers
22±0.2
4.5 dia.
(depth: 1.6)
10
4
31.5
42.9
38.7±0.2
B
Side mounting
Three, 4.3 dia.
Mounting hole
38.5
4.5 dia.
(depth: 1.6)
41.7±0.2
(63.3)
39
24.7
41.7±0.2
(55)
41.7±0.2
(55)
(144.8)
41.7±0.2
(63.3)
79.1
Release key
101.9±0.8
4.5 dia.
(depth: 1.6)
LED indicators
(17.6)
(11.4)
LED indicators
Release key
(11.4)
A
(1)
(8)
B
(17.6)
26 dia.
A-A
B-B
4.5 dia.
(depth: 1.6)
LED indicators
Conduit cap
Operating characteristics Model
1- Conduit
2- Cover mounting screw
D4SL-@@D@-D4
Head cap
D4SL-@@D@-D4N
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance
15 mm max.
Movement before being
locked
3 mm min.
29.2
29.2
9
Pre-travel distance
39
37
22±0.2
Operation Key
26.3
A
Front-side mounting
2, 4.3 dia.
Mounting hole
26.3
Spacers
22±0.2
4.5 dia.
(depth: 1.6)
10
4
31.5
42.9
38.7±0.2
Side mounting
Three, 4.3 dia.
Mounting hole
38.5
4.5 dia.
(depth: 1.6)
41.7±0.2
(63.3)
39
24.7
B
41.7±0.2
(55)
Release key
41.7±0.2
(55)
41.7±0.2
(63.3)
79.1
(169.7)
126.8±0.8
4.5 dia.
(depth: 1.6)
LED indicators
LED indicators
LED indicators
4.5 dia.
(depth: 1.6)
Release key
(11.4)
B-B
(17.6)
(11.4)
A
(1)
(8)
(17.6)
B
26 dia.
A-A
Conduit cap
2- Cover mounting screw
1- Conduit
Operating characteristics Model
D4SL-@@D@-D4
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance
15 mm max.
Movement before being
locked
3 mm min.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
17
D4SL
Operation Key
D4SL-K1
D4SL-K1S
28
19.5
28
21.5
35
7
22.7
15
7
28
13
7
35
22.7
15
7
4.3
4-R2.15
4.3
4-R2.15
2
2
D4SL-K1G
D4SL-K2
28
21.5
28
15.6
14.5
28
8
7
35
20
12
22.7
2-4.3 dia.
15
22.7
35
2-9 dia.
4.3
7
4-R2.15
15
Angle adjustment bolt
(5.2)
2
2
Mounting rubber
D4SL-K2G
D4SL-K3
17.2
14.5
28
8
17.7
28
4
22.7
35
12
4.5 dia.
8 dia.
20
9 dia.
2-4.3 dia.
2-9 dia.
2
Mounting rubber
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
18
22.7
20°
30
40
56
D4SL
Connector Cable
D4SL-CN@
(30)
L±40
10
9
8
7
6
5
4
3
2
1
Connector pin No.
(150)
(5)
Cable
AWG22, 10 conductors
*
Model
L size
D4SL-CN1
1m
D4SL-CN3
3m
D4SL-CN5
5m
Connector
* All 10 lead wires laid bare.
Connector No.
Lead wire color
Connector No.
Lead wire color
1
Black
6
Green/White
2
Black/White
7
Yellow
3
Red
8
Yellow/White
4
Red/White
9
Brown
5
Green
10
Brown/White
19
D4SL
Operation Key Mounting
D4SL + D4SL-K1
(with Front-inserted Operation Key)
59 min.
61.5 max.
Key insertion
position
D4SL + D4SL-K1
(with Top-inserted Operation Key)
Horizontal
insertion radius
R ≥ 180
(37)
Center tolerance of
(15) key hole: ±0.8
59 min.
61.5 max.
Key insertion
position
Vertical
insertion radius
R ≥ 200
(37)
Center tolerance of
key hole: ±0.8
31.5
D4SL + D4SL-K1S
(with Front-inserted Operation Key)
50.5 min.
53 max.
Key insertion
position
Vertical
insertion radius
R ≥ 200
(37)
Center tolerance of
key hole: ±0.8
D4SL + D4SL-K1G
(with Front-inserted Operation Key)
(38.5)
60.5 min.
63 max.
Key insertion
position
(38.5)
Horizontal
insertion radius
R ≥ 180
(15) Center tolerance of
key hole: ±0.8
52 min.
54.5 max.
Key insertion
position
(38.5)
Center tolerance
of key hole: ±0.8
9
52 min.
54.5 max.
Key insertion
position
Vertical
insertion radius
R ≥ 200
(38.5)
D4SL + D4SL-K1G
(with Top-inserted Operation Key)
Horizontal
insertion radius
Pitch 12 mm R ≥ 120
Pitch 20 mm R ≥ 170
(37)
59 min.
61.5 max.
Key insertion
position
(Pitch 12 mm) Center tolerance of
(Pitch 20 mm) key hole: ±0.8
Horizontal
insertion radius
Pitch 12 mm R ≥ 120
Pitch 20 mm R ≥ 170
Vertical
insertion radius
R ≥ 140
(37)
(2.6)
(28.9)
31.5
Center tolerance of
key hole: ±0.8
20
60.5 min.
63 max.
Key insertion
position
Vertical
insertion radius
R ≥ 200
Horizontal
insertion radius
R ≥ 180
(37)
31.5
59 min.
61.5 max.
Key insertion
position
(15) Center tolerance of
key hole: ±0.8
Center tolerance
of key hole: ±0.8
9
D4SL + D4SL-K1S
(with Top-inserted Operation Key)
Center tolerance of
(15) key hole: ±0.8
50.5 min.
53 max.
Key insertion
position
Horizontal
insertion radius
R ≥ 180
(38.5)
(Pitch 12 mm)
(Pitch 20 mm)
Center tolerance of
key hole: ±0.8
60.5 min.
63 max.
Key insertion
position
Vertical
Center tolerance of
insertion radius
key hole: ±0.8
R ≥ 140
9
(2.6)
(6.4)
60.5 min.
63 max.
Key insertion
position
(38.5)
D4SL
D4SL + D4SL-K2
(with Front-inserted Operation Key)
53.1 min.
55.6 max.
Key insertion
position
D4SL + D4SL-K2
(with Top-inserted Operation Key)
Horizontal
insertion radius
R ≥ 180
(37)
Center tolerance of
(15) key hole: ±0.8
53.1 min.
55.6 max.
Key insertion
position
Vertical
insertion radius
R ≥ 200
(37)
Horizontal
insertion radius
R ≥ 180
Center tolerance of
key hole: ±0.8
(15)
Center tolerance of
(17)
key hole: ±0.8
9
Vertical
insertion radius
R ≥ 200
(8)
(8)
31.5 (39.5)
54.6 min.
57.1 max.
Key insertion
position
(38.5)
54.6 min.
57.1 max.
Key insertion
position
(38.5)
Center tolerance of
key hole: ±0.8
D4SL + D4SL-K2G
(with Front-inserted Operation Key)
D4SL + D4SL-K2G
(with Top-inserted Operation Key)
Horizontal
insertion radius
Pitch 12 mm R ≥ 120
Pitch 20 mm R ≥ 170
(37)
54.7 min.
57.2 max.
Key insertion
position
(Pitch 12 mm) Center tolerance of
(Pitch 20 mm) key hole: ±0.8
Vertical
insertion radius
R ≥ 140
(37)
54.7 min.
57.2 max.
Key insertion
position
Horizontal
insertion radius
Pitch 12 mm R ≥ 120
Pitch 20 mm R ≥ 170
(Pitch 12 mm)
(Pitch 20 mm)
Center tolerance of
key hole: ±0.8
Center tolerance of
key hole: ±0.8
(17)
9
Vertical
insertion radius
R ≥ 140
(8)
(8)
31.5 (39.5)
56.2 min.
58.7 max.
Key insertion
position
(38.5)
56.2 min.
58.7 max.
Key insertion
position
(38.5)
Center tolerance of
key hole: ±0.8
D4SL + D4SL-K3
(with Front-inserted Operation Key)
55.2 min.
57.7 max.
Key insertion
position
(37)
D4SL + D4SL-K3
(with Top-inserted Operation Key)
Horizontal
insertion radius
R ≥ 50
(40±0.15)
Center tolerance of
key hole: ±0.8
55.2 min.
57.7 max.
Key insertion
position
(37)
Vertical
insertion radius
R ≥ 200
(31.5)
Center tolerance of
key hole: ±0.8
56.7 min.
59.2 max.
Key insertion
position
(38.5)
40
Vertical
Horizontal
insertion radius insertion radius
R ≥ 200
R ≥ 50
Center tolerance of
(9) key hole: ±0.8
(38.5)
56.7 min.
59.2 max.
Key insertion
position
Center tolerance of
key hole: ±0.8
21
D4SL
Application Examples
G9SA-321-T@ (24 VAC/VDC) + D4SL-@@DA-D4@ (Mechanical Lock Type) Circuit Diagram (Manual Reset)
Lock release signal
KM1
S1: Safety Limit Switch with direct opening mechanism
(D4B-N, D4N, D4F)
S2: Guard Lock Safety-door Switch
S3: Reset switch
S4: Lock release switch
KM1 and KM2: Magnetic Contactor
M: 3-phase motor
KM2
S4
S2
9
10
42
41
12
11
1
2
3
4
5
6
7
8
PLC
PLC
Guard
S1
Feedback loop
OPEN
KM1
S3
KM2
Stop signal
A1 A2 T11
T12
T31
T32
13 23 33 43 53 61
1
TH
a
K1
3
4
K3
K2
K3
SA
a
K1
b
K2
K4
OffDelay
Timer
K4
Control
Circuit
b
2 K1
5
K2
JP
1
2
3
4
5
6
6
PE T21
T23 T22
A
B
14 24 34 44 54 62
KM1 KM2
Timing Chart
(Operation instruction)
Guard opens
Limit switch
Motor controller
S1
Guard Lock
Safety-door Switch S2
KM1
Lock release signal
KM2
S4
Guard can be opened
Stop signal
M
Reset switch S3
Note: 1. The above circuit diagram is for Category 3.
2. Numbers inside the boxes are terminal numbers printed on the
product.
K1 and K2 (NC)
K1 and K2 (NO)
K3 and K4 (NC)
K3 and K4 (NO)
KM1 and KM2 (NC)
KM1 and KM2 (NO)
Operation instruction
Motor rotation
OFF-delay time
22
D4SL
G9SA-301 (24 VAC/VDC) + D4SL-@@DG-D4@ (Solenoid Lock Type) Circuit Diagram (Auto-reset)
Lock signal
S1: Safety Limit Switch with direct opening mechanism
(D4B-N, D4N, D4F)
S2: Guard Lock Safety-door Switch
KM1 and KM2: Magnetic Contactor
M: 3-phase motor
S2
9
10
42
41
12
11
1
2
3
4
5
6
7
8
PLC
PLC
S1
12
OPEN
Feedback loop
11
KM1
KM2
Operation signal
A1 A2 T11
T31
T12
T32
TH
a
13 23 33 41
3
4
1
K1
K1 K2
SA
K2
K1
b
K2
a
b
Control
Circuit
2
5
JP
1
2
3
4
5
6
6
PE T21
T23 T22
A
B
14 24 34 42
KM1 KM2
(Operation instruction)
Motor controller
Timing Chart
Guard opens
KM1
Limit switch
S1
Guard Lock
Safety-door Switch S2
KM2
Operation signal
Lock signal
M
K1 and K2 (NC)
K1 and K2 (NO)
KM1 and KM2 (NC)
KM1 and KM2 (NO)
Note: 1. This circuit diagram is for Category 4.
2. The lock can be released at any time. Therefore, do not use a
model with a solenoid lock in applications where the operator
may be exposed to danger when the guard opens. Use a model
with a mechanical lock.
3. Numbers inside the boxes are terminal numbers printed on the
product.
23
D4SL
Safety Precautions
Refer to the “Precautions for All Switches” and
“Precautions for All Safety Door Switches”.
Precautions for Correct Use
DANGER
Injury may occasionally occur. Always check to make
sure that the safety functions operate correctly before
using the machine. The safety functions may not
operate correctly because of wiring mistakes, setting
mistakes, or Switch malfunction, causing some machines to
continue operating in situations where they should be stopped.
CAUTION
Injury may occasionally occur. When the Switch
function is damaged, some machines may continue
operating in situations where they should be stopped.
Do not impose a force exceeding the key holding
force. Always provide a lock separate from the Switch, attach a
warning seal to avoid excessive force applied to the Switch, or
provide an indicator lamp to show the locked/unlocked status of
the door.
Solenoid Lock Models
• If a current is detected in the solenoid lock model (built-in switches;
N,P,Q,R), before the door is closed, the door will remain unlocked.
Be sure to supply power to the solenoid after the door is closed
(after the Operation Key is inserted).
• The solenoid lock locks the door only when power is supplied to the
solenoid. Therefore, the door will be unlocked if the power supply
to the solenoid stops. Therefore, do not use solenoid lock models
for machines that may be operating and dangerous even after the
machine stops operating.
Release Key
• The release key is used to unlock the Switch in case of emergency
or if the power supply to the Switch stops.
• If the release key setting is changed from LOCK to UNLOCK, the
lock will be released and the safety door can be opened
(mechanical lock models only).
D4SL-@@@@-@
D4SL-@@@@-@4
UNLOCK
UNLOCK
Precautions for Safe Use
Operating Environment
Do not use the Switch submersed in oil or water or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil or water entering the Switch. (The IP67 degree of protection of
the Switch specifies the amount of water penetration after the Switch
is submerged in water for a certain period of time.)
Wiring
• Do not switch circuits for three or more standard loads (125 VAC, 1
A). Doing so may adversely affect insulation performance.
• Do not allow the load current to exceed the rated value.
• For metal connector, use a connector with the screw length of 9
mm or less. Otherwise it may result in electric shock.
• Do not use metallic conduits. In the event of damage to the conduit
opening, this may cause seal failure and may result in electric
shock.
• Do not use a metal connector for a 1/2-14NPT connector. In the
event of damage to the conversion adapter, this may cause seal
failure and may result in electric shock.
• Always attach the cover after completing wiring and before using
the Switch. Do not supply power when the cover is not attached.
Electric shock may occur if the Switch is used without the cover
attached.
• When using the terminal block type, make sure that foreign
material does not adhere to the terminal block board. Otherwise a
short circuit may occur between terminals and safety functions
may fail to work properly.
Installation
• Make sure the Switch is mounted securely to prevent it from falling
off. Otherwise injury may result.
• Do not use a Switch as a stopper.
Head
Stopper
Be sure to install a stopper as shown in the
following illustration so that the Operation
Key does not touch the head.
Do not subject the Switch to a shock that
exceeds the Switch's shock resistance of
Operation Key
1,000 m/s2.
Switch
24
LOCK
LOCK
• After setting the release key to UNLOCK to, for example, perform
maintenance, be sure to return it to LOCK setting before resuming
operation.
• The release key is set in the unlock position at the factory for the
D4SL-@@@A and to the lock position for the D4SL-@@@G.
• In the unlock position, even when the door of large machines or
stamping machines is closed during preliminary adjustment, the
door will remain unlocked and the machines will not be activated.
• Do not use the release key to start or stop machines.
• The auxiliary lock must be released only by authorized personnel.
• Do not impose a force exceeding 0.2 N·m on the release key
screws. The release key may be damaged and may not operate
properly.
• To prevent the release key from being used by unauthorized
personnel, set it to LOCK and seal it with sealing wax.
Mounting Covers
• Confirm that the seal rubber has no defects before use. If the seal
rubber is displaced or raised, or has foreign particles adhered to it,
the sealing capability of the seal rubber will be adversely affected.
Hinged Door
If the Switch is mounted too close to the hinge, the force imposed on
the lock will be much larger than for locations far from the hinge and
the lock may be damaged. Mount the Switch close to the handle.
D4SL
Mounting
Spacer
Appropriate Tightening Torque
Do not remove a spacer. Rotate the spacer in accordance with the
Switch mounting direction. Use of the Switch without spacer will
reduce the lock strength.
Loose screws may result in malfunction. Tighten the screws to the
specified torques.
Cover mounting
screw
0.4 to 0.5 N·m
2.4 to 2.8 N·m (D4SL-K@, -K@S)
Operation Key
mounting screw
Mounting side
0.75 to 1.15 N·m (D4SL-K@G)
Switch mounting
screw
0.75 to 1.15 N·m
Spacer
1.8 to 2.2 N·m (except 1/2-14NPT)
Connector
1.4 to 1.8 N·m (for 1/2-14NPT)
Wiring
Terminal screw
* Terminal block type 0.5 to 0.6 N·m (D4SL-@@@@-@@)
only.
Switch and Operation Key Mounting
• Mount the Switch and Operation Key securely to the applicable
tightening torque with M4 screws. Always use washers.
Switch mounting
Front
Operation Key mounting
2-M4
D4SL-K1/-K2
22±0.1
2-M4
15±0.1
Side
D4SL-K1G/-K2G
2-M4
10±0.1
• Direct opening contacts used as safety-circuit inputs are indicated
with the
mark. Terminals 11-42, and terminals 21-52 have
direct opening contacts.
• DC solenoids have polarity. (E1: +, E2: -) Confirm terminal polarity
before wiring.
• The current of the 24 VDC solenoid is different from when it is first
turned ON as to when it is in operation. To take into account
possible voltage drops, it is important to apply a rated operation
voltage.
• To enable the 24 VDC solenoid, it is necessary to select the
appropriate power supply capacity.
• The ON and OFF contact operation will not engage simultaneously.
Be sure to confirm operation under actual operating conditions.
(D4SL-@NDA, D4SL-@NDG)
12±0.1 or 20±0.1
3-M4
38.7±0.1
Circuit Connection Example
D4SL-K3
2-M4
9
E1
(+)
10
E2
(-)
Door open/closed
detection switch
LED
22±0.1
40±0.1
• Ensure that the alignment offset between the Operation Key and
the key hole does not exceed ±0.8 mm.
If the Operation Key is offset or at an angle, accelerated wear or
damage to the Switch may result.
• Observe the specified insertion radius for the Operation Key and
insert it in a direction perpendicular to the key hole.
• Mount a provided cap head to an unused Operation Key hole.
• Perform 3-point mounting including the head for side mounting.
Securing the Door
When the door is closed (with the
Operation Key inserted), the
Operation Key may exceed the set
zone because of, for example, the
door's own weight, machine vibration,
or the door cushion rubber.
Secure the door with a stopper (hook)
so that the Operation Key remains
within the set zone.
2
42
41
12
11
1
Safety circuit
4
52
51
22
21
3
Safety circuit
8
64
63
34
33
5
Control circuit
7
6
Lock monitor
switch
Control circuit
(D4SL-@JDG)
9
E1
(+)
10
E2
(-)
Door open/closed
detection switch
LED
Set zone
(0.5 to 3 mm)
Operation Key
2
42
6
52
8
64
Lock monitor
switch
41
12
63
34
7
4
11
1
Safety circuit
51
5
Control circuit
33
3
Control circuit
Control circuit
25
D4SL
Processing the Conduit Opening
Wiring Precautions for D4SL-@@@@-@@
• Do not wire the Switch while power is being supplied. Doing so may
result in electric shock.
• Do not let particles, such as small pieces of lead wire, enter the
switch body when wiring.
• Do not directly wire the stranded wire to the terminal block.
• When connecting to the terminals via insulating tube and bar
terminals, arrange the bar terminals so that they do not rise up onto
the case or the cover.
• Applicable lead wire size: AWG22 to AWG18 (0.3 to 0.75 mm2).
• Use lead wires of an appropriate length. Not doing so may result in
excess length causing the cover to rise and not fit properly.
• Remove the terminal block board out of the unit to perform wiring.
Be sure to insert the connector properly.
1
1 3 5
7
3
5
7
9
Recommended Connectors
• Use a connector with a screw section not exceeding 9 mm.
Otherwise the screws will protrude into the case interior. The
connectors given in the following table have connectors with screw
sections not exceeding 9 mm.
Use the following connectors to ensure conformance to IP67.
Size
40±3mm
9
• Connect a recommended connector to the opening of the conduit
and tighten the connector to the proper torque. The case may be
damaged if excessive tightening torque is applied.
• Use the cable with the connector-specified outside diameter.
• For the 1/2-14NPT conduit, mount a provided conversion adapter
to use the connector above.
Manufacturer
LAPP
G1/2
2 4 6
8 10
30±3mm
2
4
6
8 10
• Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
Recommended Crimp Terminals
Manufacturer
PHOENIX
CONTACT
L1: 14 mm max.
L2: 8 mm max.
Model
Applicable wire lead
AI0.34-8 TQ
AWG22
AI0.5-8 WH
AWG20
AI0.75-8 GY
AWG18
L1
L2
Wiring Precautions for D4SL-@@@@-@@N
• Do not wire the Switch while power is being supplied. Doing so may
result in electric shock.
• Do not let particles, such as small pieces of lead wire, enter the
switch body when wiring.
• Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm2). Do
not apply a current of 2 A or more when using AWG24.
• Use lead wires of an appropriate length. Not doing so may result in
excess length causing the cover to rise and not fit properly.
1
2
1 2
3
4
5
6
10
10
30±3mm
• Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
• Do not forcibly insert the wired socket at the cable side into the
connector or D4SL’s conduit opening. Doing so may cause cable
break.
Be sure to insert the cable into the connector or D4SL’s conduit
opening before performing wiring to the socket, or insert the cable
into the connector or conduit opening from the opposite side of the
socket.
Applicable socket for cable side
Manufacturer
J.S.T. Mfg Co.
26
Name
Model
Housing
XHP-10
Contact
(applicable wire lead:
AWG24 to AWG22)
SXH-001T-P0.6
Ace Service
Co.
Model
Applicable
Remarks
cable diameter
ST-PF1/2
5380-1002
6.0 to 12.0 mm
LS-2G
6.0 to 11.0 mm
M20
LAPP
ST-M20X1.5
5311-1020
7.0 to 13.0 mm
1/214NPT
LAPP
ST-NPT1/2
5301-6030
6.0 to 12.0 mm
Short
type
Use LAPP connectors together with Seal Packing (JPK-16 for G1/2,
or GPM20 for M20), and tighten to the applicable torque. Seal
Packing is sold separately.
• LAPP is a German manufacturer.
• Ace Service Co. is a Japanese manufacturer.
READ AND UNDERSTAND THIS CATALOG
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Copyright and Copy Permission
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON SCIENTIFIC TECHNOLOGIES INC.
6550 Dumbarton Circle, Fremont
CA 94555-3605 U.S.A.
Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2010 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Printed in Japan
CSM_3_1_0311
Cat. No. C143-E1-01
0310