D7FS0305

D7FS0305

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Vibration Sensor 3-Pin

  • 数据手册
  • 价格&库存
D7FS0305 数据手册
Vibration Sensor with Linear Output or Manual Setting D7F Detects Changes in Machine Vibration „ ON/OFF output can be set and checked quickly and easily from the vibration level meter. „ Vibration waveforms can be checked using the AC monitor output. „ The IP67 rating enables use in harsh environments. „ Selectable acceleration and speed available with Linear Output Models. „ Five operating modes ensure highly accurate error detection. Vibration/ Inclination/ Other Sensors Vibration Sensors Inclination Sensors Be sure to read Safety Precautions on page 1218. Ordering Information Sensors Appearance Liquid Leakage Sensors Manually set Liquid Leakage Sensor Accessories Linear output Other Controllers Information Appearance D7F 1214 Type Type Cable length Model 5m D7F-S01-05 10 m D7F-S01-10 5m D7F-S03-05 Model Manually set D7F-C01 Linear output D7F-C03 D7F Ratings and Specifications Sensors Manually Set Models D7F-S01-05/D7F-S01-10 Sensitivity 5.1 mV/(m/s2) (typical) Detection frequency 20 Hz to 2 kHz (±3 dB) Resonance frequency Approx. 5 kHz Max. acceleration 784 m/s2 Shock resistance 29,400 m/s2 Vibration resistance 10 Hz to 2 kHz, 2-mm single amplitude or 392 m/s2 Degree of protection IP67 (IEC 60529) Insulation resistance 20 MΩ min. at 100 VDC between the case and all terminals Dielectric strength 1,000 VAC between the case and all terminals at 50/60 Hz for 1 min Ambient temperature −25 to 70°C (with no icing or condensation) Ambient humidity 25% to 95% (with no icing or condensation) Cable length 5 m, 10 m Tightening torque 4.4 to 5.4 N·m Weight Approx. 40 g (excluding the cable) Linear Output Model D7F-S03-05 Operating temperature range −25 to 70°C Operating humidity range 25% to 95% Storage temperature −40 to 80°C Connectable vibration sensor Controller D7F-C03 Vibration resistance 10 to 150 Hz, 0.35-mm single amplitude or 50 m/s2 Shock resistance 150 m/s2 Degree of protection IP67 (IEC 60529) Sensitivity * 5.1mV/(m/s2) ±20 (at 100 Hz) Frequency range 10 to 2,000 Hz (±3 dB) Max. acceleration 98 m/s2 (rms) Weight Approx. 40 g (excluding the cable) * Sensor characteristic Vibration/ Inclination/ Other Sensors Vibration Sensors Inclination Sensors Liquid Leakage Sensors Liquid Leakage Sensor Accessories Other Information D7F 1215 D7F Controllers Manually Set Model D7F-C01 Vibration/ Inclination/ Other Sensors Vibration Sensors Inclination Sensors Liquid Leakage Sensors Liquid Leakage Sensor Accessories Linear Output Model D7F-C03 Frequency range 20 Hz to 20 kHz Power supply voltage range 12 to 24 VDC±10% (10.8 to 26.4 VDC) Current consumption 200 mA max. Relay output SPDT (30 VDC, 3 A or 250 VAC, 3 A resistive load) Monitor output * 5.1 mV (m/s2) Operations Mode selector (MODE) Gain selector (GAIN) Sensitivity adjuster (SENS) Power supply voltage range 12 to 24 VDC±10% (10.8 to 26.4 VDC) Current consumption 100 mA max. Operating temperature range −10 to 55°C Operating humidity range 25% to 85% Storage temperature range −25 to 65°C Connectable Vibration Sensor D7F-S03-05 Vibration resistance 10 to 150 Hz, 0.35-mm single amplitude or 50 m/s2 Shock resistance 150 m/s2 Output range 4 to 20 mA Allowable load resistance 300 Ω max. 1s Output configuration NPN open collector Vibration level indicator 10-level meter Residual voltage 1.5 V max. Additional functions Relay output for a sensor cable disconnection and a flashing level meter ON delay 0.1 s min. in Continuous Vibration Detection Mode 5 ms in Intermittent Vibration Detection Mode OFF delay Destruction: 10 to 150 Hz, 0.75-mm single Vibration resistance amplitude, maximum acceleration of 98m/s2 Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: −20 to 60°C (with no icing or condensation) Ambient humidity Operating: 25% to 95% (with no icing or condensation) Connectable Vibration Sensor D7F-S01-@@ Analog DC Transistor Leakage current 0.1 mA max. Max. load voltage 26.4 VDC Max. sink current 100 mA max. Output Range Acceleration (X value) ×1 5.1 mV/(m/s2) ×3 15.3 mV/(m/s2) × 10 51 mV/(m/s2) × 30 153 mV/(m/s2) × 100 510 mV/(m/s2) 50 ms min ACC (reference values) × 1 range, 5.1 mV/(m/s2) (typical) × 5 ranges, 25.5 mV/(m/s2) (typical) × 10 ranges, 51 mV/(m/s2) (typical) VEL (reference values) × 1 range, 25.4 mV/(mm/s) (typical) × 5 ranges, 127 mV/(mm/s) (typical) × 10 ranges, 254 mV/(mm/s) (typical) Impedance 10 kΩ AC monitor * Approx. 120 g Other Weight Information * The following table shows typical AC monitor outputs. X Min. output time Weight Approx. 120 g * The AC monitor output is used to check simple waveforms. Do not use it for precision measurements or waveform analysis. The following diagram shows the monitor output voltage. ACC (acceleration) D7F 0 to 98 m/s ×5 0 to 19.6 m/s2 0 to 4 mm/s × 10 0 to 9.8 m/s2 0 to 2 mm/s Frequency range 20 to 2,000 Hz 10 to 1,000 Hz Linearity ±5% F.S. (at 100 Hz)* Gain error ±5% F.S. (at 100 Hz)* Zero point offset 4±0.2 mA (at 20°C)* * Controller characteristic 1216 VEL (velocity) ×1 Range (rms) 2 0 to 20 mm/s D7F Nomenclature Manually Set Model • D7F-C01 Vibration Sensor Controller Vibration Sensor Controllers process signals from Vibration Sensors, detect errors, and produce an external output. Monitor output ± 4 VAC (Impedance: 10 Ω) Relay output (4) Operations (1) MODE Selector (2) GAIN Selector (1 to 100 x) Selects the waveform processing mode. The GAIN Selector is used to change the signal strength. Application MODE Waveform Example: Increasing signal strength example A 20 Hz to 20 kHz General purpose, monitoring, etc. B Continu- 20 Hz to 200 Hz ous (5) (6) (7) C vibration 200 Hz to High-speed rotating detection 2 kHz object error, etc. D 2 kHz to 20 kHz (3) E Intermittent vibration detection Threshold Vibration Imbalance, deviation, etc. Bearing damage, etc. (3) Sensitivity Adjuster The sensitivity adjuster is used to change the threshold setting. L side Contact, shock, etc. Threshold H side Vibration (1) Applicable in Wet Environments The IP67 (dust-proof and immersion-proof) rating for Vibration Sensors enables application in harsh environments, including those exposed to water. • D7F-S01-@@ Vibration Sensor (2) A quick-mounting magnet is provided to help locate the detection position. Vibration Sensors use piezoelectric ceramic devices to convert vibration to electrical signals. Sensor Frequency Characteristics Indicators (4) LEVEL METER The Level Meter indicator clearly shows the vibration level. (5) POWER The POWER indicator is lit when the power is ON. (6) OUTPUT The OUTPUT indicator is lit when the output relay is operating. (7) OVER The OVER indicator is lit when vibration is detected. Terminology The following diagram shows ON and OFF delay times. Output Vibration input Yes OFF 5 kHz (Resonance point) Frequency ON delay OFF delay Linear Output Model D7F-C03 Inclination Sensors Liquid Leakage Sensor Accessories Relay output ON 2 kHz Vibration Sensors Liquid Leakage Sensors No 0 dB 20 Hz Vibration/ Inclination/ Other Sensors Other Information Indicators (5) Level (10 levels) RUN: Indicates vibration magnitude. SET: Indicates threshold settings. (5) Level Meter (6) (7) (3) (8) (2) (1) (4) Operations (1) RUN/SET Selector The RUN/SET Selector sets the Level Meter indication to RUN or SET. (2) ACC/VEL Selector The ACC/VEL Selector sets the operating mode to acceleration or velocity. (3) GAIN Selector The GAIN Selector changes the signal strength. (4) Threshold Adjuster The Threshold Adjuster sets the threshold value. levels 10 9 8 7 6 5 4 3 2 1 Vibration level and threshold settings 95% or higher F.S. 85% to 95% F.S. 75% to 85% F.S. 65% to 75% F.S. 55% to 65% F.S. 45% to 55% F.S. 35% to 45% F.S. 25% to 35% F.S. 15% to 25% F.S. 5% to 15% F.S. (7) OUTPUT Indicator The output transformer operates and the OUTPUT indicator lights at vibration levels exceeding the threshold setting. The output and indications are the same whether RUN or SET is selected. (8) SET Indicator The SET Indicator is lit when SET is selected from the RUN/SET selector. D7F Note: Use the Level Meter indicator strictly as a guideline. (6) PWR/ALM Indicator Power ON: Green light Sensor error: Red light 1217 D7F Safety Precautions Refer to Warranty and Limitations of Liability on page F-2. Precautions for Safe Use Do not perform wiring work or touch any terminals with power supplied. Doing so may result in electric shock. Precautions for Correct Use Do not use this product in atmospheres or environments that exceed product ratings. Sensor Installation Vibration/ Inclination/ Other Sensors • Wipe the mounting surface to remove all dirt and use a No. 17 wrench to secure the D7F in place. Optimum tightening torque: 4.4 to 5.4 N·m Mounting hole dimensions: M6 holes, Depth: 7 mm min. • The D7F may not operate correctly if it is not secured with the proper torque or the mounting surface is not cleaned properly prior to installation. • The quick-mounting magnet is provided to help locate the proper detection position. Make sure the D7F is secured with screws for long-term applications. • The quick-mounting magnet will not hold the D7F if the magnet is installed vertically or backwards. Quick-mounting Magnet Dimensions Handling the Sensor • The Sensor Cable can be cut to any length, but it cannot be extended. • Do not disassemble the D7F. Otherwise, it may not operate properly. • Make sure all wiring is correct and be careful not to short wires while wiring. • Do not install the D7F in locations subject to oil. Otherwise, the rubber seal will deteriorate, allowing liquids such as oil or water to enter the D7F, which may cause it to fail. • The D7F should be connected only to a specified Controller, such as the D7F-C01 or D7F-C03. Handling the Controller • The Controller should be connected only to a specified Sensor, such as the D7F-S01-@@ or D7F-S03-@@. • Do not attempt to disassemble the Controller. Otherwise, it may not operate properly. • Do not install the Controller in a dusty location or one subject to water or oil. • Do not mount the Controller directly to any source of vibration. Removing the D7F from a DIN Track M6 Vibration Sensors 9.2+0.2 0 • Remove the D7F from a DIN Track as shown in the diagram on the right. 23 dia. Inclination Sensors Sensor Mounting Direction • Mount the D7F as indicated by the circle in the diagram below. Liquid Leakage Sensors Liquid Leakage Sensor Accessories Other Information D7F 1218 Correct Incorrect Sensor Vibration direction Sensor Vibration direction Vibration direction Sensor Sensor Vibration direction Flat-blade screwdriver (Blade width: 4 mm max.) D7F Dimensions (Unit: mm) Sensors D7F-S01-05 D7F-S01-10 Mounting screw (M6) 5,000±100* 5 23 6 0 17−0.25 (55) 1.5 0 17−0.25 16 dia. Cable (4 dia.) 6.5±0.4 *10,000 ±100 for a cable 10 m long. D7F-S03-05 0 17−0.25 16 dia. 13 dia. Heat shrinkable tubing 6 dia.4 dia. M6 0 17−0.25 1.5 6.5±0.4 5 23 6 6 5,000±100 35±5 Controllers D7F-C01 Mounting Hole Dimensions 45 Two, M3.5 72.4 (67) 75 35.2 67+10 Vibration/ Inclination/ Other Sensors Vibration Sensors Inclination Sensors Liquid Leakage Sensors Liquid Leakage Sensor Accessories Other Information D7F-C03 (0.5) 45 Mounting Hole Dimensions 72.4 4.8 dia. 4.3 Two, M3.5 4 35.2 75 Ten, M3.5 67 67+10 4.8 D7F 7 Cat. No. F835-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1219
D7FS0305 价格&库存

很抱歉,暂时无法提供与“D7FS0305”相匹配的价格&库存,您可以联系我们找货

免费人工找货