Long Distance Cylindrical Proximity Sensor
E2A3
.
Extra long distance for
increased protection and
sensing performance
• triple distance proximity sensors for flush mounting requirements.
• designed and tested for extra long life.
Ordering Information
Size
Type
Sensing
distance
Connection
Pre-wired
M8
Shielded
3.0mm
M12
connector
M8
connector
(3-pin)
Body
material
Operation mode: NO
Operation mode: NC
6.0mm
PNP
NPN
PNP
Stainless steel 27 (44) mm
NPN
(See note.)
PNP
27 (40) mm
NPN
E2A3-S08KS03-WP-B1 2M
E2A3-S08KS03-WP-C1 2M
E2A3-S08KS03-M1-B1
E2A3-S08KS03-M1-C1
E2A3-S08KS03-M5-B1
E2A3-S08KS03-WP-B2 2M
E2A3-S08KS03-WP-C2 2M
E2A3-S08KS03-M1-B2
E2A3-S08KS03-M1-C2
E2A3-S08KS03-M5-B2
E2A3-S08KS03-M5-C1
E2A3-S08KS03-M5-C2
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
E2A3-M12KS06-WP-B1 2M
E2A3-M12KS06-WP-C1 2M
E2A3-M12KS06-M1-B1
E2A3-M12KS06-M1-C1
E2A3-M18KS11-WP-B1 2M
E2A3-M18KS11-WP-C1 2M
E2A3-M18KS11-M1-B1
E2A3-M18KS11-M1-C1
E2A3-M30KS20-WP-B1 2M
E2A3-M30KS20-WP-C1 2M
E2A3-M30KS20-M1-B1
E2A3-M30KS20-M1-C1
E2A3-M12KS06-WP-B2 2M
E2A3-M12KS06-WP-C2 2M
E2A3-M12KS06-M1-B2
E2A3-M12KS06-M1-C2
E2A3-M18KS11-WP-B2 2M
E2A3-M18KS11-WP-C2 2M
E2A3-M18KS11-M1-B2
E2A3-M18KS11-M1-C2
E2A3-M30KS20-WP-B2 2M
E2A3-M30KS20-WP-C2 2M
E2A3-M30KS20-M1-B2
E2A3-M30KS20-M1-C2
34 (50) mm
Brass
M12
connector
34 (49) mm
Pre-wired
M18 Shielded
11.0mm
39 (60) mm
Brass
M12
connector
39 (54) mm
Pre-wired
M30 Shielded
20.0mm
44 (65) mm
Brass
M12
connector
Output
27 (40) mm
Pre-wired
M12 Shielded
Thread
length
44 (59) mm
Note: Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS303 (AISI), 2346 (SS).
E2A3
D-35
E2A3
DC 3-wire Models
Connectivity
E2A3 Sensors are available with the following connectors and cable materials:
Pre-wired Models
Connector Models
Standard connectors: M12, M8 (3-pin)
Standard cable lengths are 2 m and 5 m.
For other cable lengths, please contact your OMRON
representative.
Standard cable material: PVC (4-mm dia.)
-M1, -M5
-WP
Model Number Legend
E2A@-@@@@@-@-@@-@@
1
2 3 4 5 6 7 8 9 10 11 12
Example: E2A3-M12KS06-M1-B1
Triple distance, M12, standard barrel, shielded, Sn = 6 mm, M12 connector, PNP-NO
E2A3-S08KS03-WP-B1 2M Triple distance, M8 stainless steel, standard barrel, shielded, Sn = 3 mm, pre-wired PVC cable,
PNP-NO, cable length = 2 m
1. Basic name
E2A
8. Kind of connection
WP:
2. Sensing technology
Blank:
Standard double distance
3:
Triple distance
3. Housing shape and material
M:
Cylindrical, metric threaded, brass
S:
Cylindrical, metric threaded, stainless steel
4. Housing size
08:
8 mm
12:
12 mm
18:
18 mm
30:
30 mm
5. Barrel length
K:
Standard length
L:
Long body
Pre-wired, PVC, 4-mm dia.
M1:
M12 connector (4-pin) *
M5:
M8 connector (3-pin)
9. Power source and output
B:
DC, 3-wire, PNP open collector
C:
DC, 3-wire, NPN open collector
10.Operation mode
1:
Normally open (NO)
2:
Normally closed (NC)
11.Specials (e.g., cable material, oscillating frequency)
12.Cable length
Blank:
Connector Model
Numeral: Cable length
6. Shield
S:
Shielded
N:
Non-shielded
7. Sensing distance
Numeral: Sensing distance: e.g., 03 = 3 mm, 11 = 11 mm
D-36
Inductive Sensors
Specifications
DC 3-wire Models
Item
Sensing distance
Ambient temp. of
−25 to 70°C
Setting
distance
Ambient temp. of
−10 to 60°C
Differential travel
Target
Standard sensing object
Response frequency (See note 1.)
Power supply voltage
(operating voltage range)
Current consumption
Output type
Control output
Load current
Residual voltage
Indicator
Operation mode
Protection circuits
Ambient air temperature
Temperature influence
Ambient humidity
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
M8
Shielded
M12
Shielded
M18
M30
Shielded
Shielded
E2A3-S08KS03-@@-B@ E2A3-M12KS06-@@-B@ E2A3-M18KS11-@@-B@ E2A3-M30KS20-@@-B@
E2A3-S08KS03-@@-C@ E2A3-M12KS06-@@-C@ E2A3-M18KS11-@@-C@ E2A3-M30KS20-@@-C@
3 mm ± 10%
6 mm ± 10%
11 mm ± 10%
20 mm ± 10%
0 to 2.1 mm
0 to 4.2 mm
0 to 7.7 mm
0 to 14 mm
0 to 2.4 mm
0 to 4.8 mm
0 to 8.8 mm
0 to 16 mm
20% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
9 × 9 × 1 mm
18 × 18 × 1 mm
33 × 33 × 1 mm
60 × 60 × 1 mm
700 Hz
350 Hz
250 Hz
80 Hz
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
10 mA max.
-B models: PNP open collector
-C models: NPN open collector
200 mA max. (32 VDC max.)
2 V max. (under load current of 200 mA with cable length of 2 m)
Operation indicator (Yellow LED)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Power source circuit reverse polarity protection, Output reverse polarity protection, Power source circuit reverse polarity protecSurge suppressor, Short- tion, Surge suppressor, Short-circuit protection
circuit protection
Operating: −25°C to 70°C, Storage: −25°C to 70°C
±20% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
−10% to +20% of sensing distance at 23°C within temperature range of −10°C to 60°C
Operating: 35% to 95%, Storage: 35% to 95%
±1% max. of sensing distance in rated voltage range ±15%
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2, 10 times each 1,000 m/s2, 10 times each in X, Y and Z directions
in X, Y, and Z directions
IP67 after IEC 60529
Standards and listings
IP69K after DIN 40050
(See note 2.)
EMC after EN60947-5-2
-WP models: Pre-wired Models (4-mm dia. PVC cable with length of 2 m)
Connection method
-M1 models: M12 4-pin Connector Models
-M5 models: M8 3-pin Connector Models
Pre-wired Models Approx. 65 g
Approx. 85 g
Approx. 160 g
Weight
M12
Connector
Models:
(packed state) Connector Models
Approx. 35 g
Approx. 70 g
Approx. 20 g
Case
Stainless steel
Brass-nickel plated
Sensing surface
PBT
Material
Cable
PVC
Clamping nut
Stainless steel
Brass-nickel plated
Shock resistance
Approx. 280 g
Approx. 200 g
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard sensing object length between sensing objects, and a set distance of half the sensing distance.
2. For USA and Canada: use class 2 circuit only.
E2A3
D-37
E2A3
Size
Type
Engineering Data
Sensing distance X (mm)
Operating Range (Typical)
22
20
18
Y
16
X
14
E2A3-M30KS20
12
E2A3-M18KS11
10
E2A3-M12KS06
8
E2A3-S08KS03
6
4
2
0
−30
−20
−10
0
10
20
30
Distance Y (mm)
E2A3-S08KS03
E2A3-M12KS06
E2A3-M18KS11
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Influence of Sensing Object Size and Materials
3.5
@d
X
3.0
Iron
t = 1 mm
2.5
Stainless steel (SUS303)
2.0
Brass
1.5
Aluminum
1.0
7
@d
X
6
t = 1 mm
5
Iron
Stainless steel (SUS303)
4
Brass
Aluminum
3
Copper
0.5
10
t = 1 mm
X
Iron
10
Stainless steel (SUS303)
8
6
Brass
4
Aluminum
Copper
2
1
5
@d
2
Copper
0.0
0
12
15
20
25
Side length of sensing object d (mm)
0
0
5
10
15
20
25
30
Side length of sensing object d (mm)
0
0
10
20
30
40
50
Side length of sensing object d (mm)
Sensing distance X (mm)
E2A3-M30KS20
25
@d
X
t = 1 mm
Iron
20
Stainless steel (SUS303)
15
Brass
10
Aluminum
Copper
5
0
0
10
20
30
40
50
60
Side length of sensing object d (mm)
D-38
Inductive Sensors
Operation
DC 3-wire Models
PNP Output
Operation mode
Model
Timing chart
Non-sensing area
Output circuit
Sensing area
Brown
Proximity
Sensor
+V
Sensing
object
(%)
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
Load
ON
OFF
NO
Black
(See note 1.)
E2A3-@-@-B1
ON
OFF
Blue
0V
Yellow indicator
Control output
Note 1: With M8 Size Models, there is no output reverse
polarity protection diode.
M12 Connector M8 Connector
Pin Arrangement
(3-pin)
(See note 2.) Pin Arrangement
4
1
2
4
3
1
3
Note 2: Terminal 2 of the M12 connector is not used.
Non-sensing area
Sensing area
Brown
Proximity
Sensor
+V
Sensing
object
100
Rated
sensing
distance
E2A3-@-@-B2
)
(See note 1.)
Load
ON
NC
Black
(M8 connector:
Proximity
Sensor
main
circuits
0
OFF
Blue
Yellow indicator
ON
OFF
Control output
0V
Note 1: With M8 Size Models, there is no output reverse
polarity protection diode.
M12 Connector M8 Connector
(3-pin)
Pin Arrangement
(See note 2.) Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
E2A3
D-39
E2A3
(%)
DC 3-wire Models
NPN Output
Operation mode
Model
Timing chart
Non-sensing area
Output circuit
Sensing area
Brown
Proximity
Sensor
Sensing
object
(%)
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
NO
+V
OFF
E2A3-@-@-C1
ON
OFF
(See note 1.) Black
Blue
0V
Yellow indicator
Control output
Note 1: With M8 Size Models, there is no output reverse
polarity protection diode.
M12 Connector M8 Connector
(3-pin)
Pin Arrangement
(See note 2.) Pin Arrangement
4
1
2
4
3
1
3
Note 2: Terminal 2 of the M12 connector is not used.
Non-sensing area
Sensing area
Brown
Proximity
Sensor
Sensing
object
(%)
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
OFF
NC
E2A3-@-@-C2
+V
(M8 connector:
)
Blue
0V
Yellow indicator
ON
OFF
(See note 1.) Black
Control output
Note 1: With M8 Size Models, there is no output reverse
polarity protection diode.
M12 Connector M8 Connector
(3-pin)
Pin Arrangement
(See note 2.) Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
D-40
Inductive Sensors
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Pre-wired Models
E2A3-S08KS03-WP-@@
E2A3-M18KS11-WP-@@
59.6
40
39
26.8
4
6
24
5
(See note 1.)
Indicator (See note 2.)
Two, clamping nuts
M8×1
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2; Insulator diameter: 1.3 mm),
Standard length: 2 m
2. Operation indicator (yellow)
E2A3-M12KS06-WP-@@
15
(See note 1.)
Indicator (See note 2.)
M18×1
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2; Insulator diameter: 1.3 mm),
Standard length: 2 m
2. Operation indicator (yellow)
E2A3-M30KS20-WP-@@
50.4
34
64.6
5.5
17
12
44
36
7
15
(See note 1.)
Indicator (See note 2.)
M12×1
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2; Insulator diameter: 1.3 mm),
Standard length: 2 m
2. Operation indicator (yellow)
(See note 1.)
Indicator (See note 2.)
M30×1.5
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2; Insulator diameter: 1.3 mm),
Standard length: 2 m
2. Operation indicator (yellow)
M12 Connector Models
E2A3-S08KS03-M1-@@
E2A3-M18KS11-M1-@@
54.2
43.9
39
26.8
4
13
6
24
5
M12×1
Indicator (See note.)
Two, clamping nuts
M8×1
15
M12×1
Indicator (See note.)
M18×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A3-M12KS06-M1-@@
E2A3-M30KS20-M1-@@
59.2
49.2
44
34
5.5
17
36
12
7
15
M12×1
M12×1
M12×1
Indicator (See note.)
Indicator (See note.)
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
M30×1.5
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
E2A3
D-41
E2A3
13
M8 Connector Models
E2A3-S08KS03-M5-@@
39.8
26.8
4
5
13
M8×1
M8×1
Indicator (See note.)
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor Dimension F (mm)
M8
F
D-42
M12
+0.5
8.5 dia. 0
+0.5
0
12.5 dia.
+0.5
0
M18
18.5 dia.
M30
30.5 dia.
+0.5
0
Inductive Sensors
Safety Precautions
Precautions for Safe Use
Wiring
Be sure to wire the E2A3 and load correctly, otherwise it may be
damaged.
WARNING
Connection with No Load
This product is not designed or rated for ensuring safety
of persons.
Do not it for such purposes.
Be sure to insert a load when wiring. Make sure to connect a proper
load to the E2A3 during operation, otherwise it may damage internal
elements.
Power Supply
Do not impose an excessive voltage on the E2A3, otherwise it may
be damaged. Do not impose AC current (100 to 240 VAC) on any DC
Model, otherwise it may be damaged.
Load Short-circuit
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
Do not short-circuit the load, or the E2A3 may be damaged.
The E2A3’s short-circuit protection function will be valid if the polarity
of the supply voltage is correct and within the rated voltage range.
Precautions for Correct Use
Power OFF
Designing
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If separate power supplies are connected to the Proximity Sensor and load, be sure to supply power to the Proximity Sensor
before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2A3 within a metal panel, ensure that the
clearances given in the following tables are maintained.
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
A
l
Power Supply Transformer
E2A3
Power Reset Time
B
A
n
d dia.
m
D
l
m
(Unit: mm)
Dimension
Model
Material of
surrounding
metal
l
E2A3
Shielded
M8
Nonferrous
metal
Ferrous
metal
0.5 (*)
(Unit: mm)
M12
2 (*)
2 (*)
m
9
18
d
24
36
D
0.5
n
24
2
Nonferrous
metal
Ferrous
metal
1 (*)
2
Type
Shielded
Dimension
M8
A
25
B
20
M12
35
25
M18
70
45
M30
110
70
1
36
(Unit: mm)
Dimension
Model
E2A3
Shielded
Material of
surrounding
metal
M18
Ferrous
metal
l
4 (*)
m
33
d
54
D
4
n
54
M30
Nonferrous
metal
2.5 (*)
Nonferrous
metal
Ferrous
metal
6 (*)
4 (*)
60
90
2.5
6
4
90
* Using the nuts provided with the E2A3 allows mounting in the way shown below.
Nut provided with E2A3
l = 0 mm
E2A3
D-43
Wiring
Maintenance and Inspection
High-tension Lines
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
The standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistance.
Do not tighten the nut with excessive force. A washer must be used
with the nut.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environmental conditions.
5. Check for proper lighting of indicators (for models with a set indicator).
Never attempt to disassemble or repair the Sensor.
Environment
Water Resistivity
The Proximity Sensors are tested intensively on water resistance, but
to ensure maximum performance and life expectancy, avoid immersion in water and provide protection from rain or snow.
Operating Environment
Store and operate the Proximity Sensor only within the given specifications.
M8
Type
Stainless Steel Model
Brass Model
M12
M18
M30
Torque
9 N·m
--20 N·m
60 N·m
150 N·m
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor. Connect the load to the Proximity
Sensor through a relay.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the
customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON
representative at any time to confirm actual specifications of purchased product.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D102-E2-01A-X
D-44
In the interest of product improvement, specifications are subject to change without notice.
Inductive Sensors