0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E2AM08KN04M1B1

E2AM08KN04M1B1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Proximity Sensor NO PNP 4mm 10V to 32V 4-Pin

  • 数据手册
  • 价格&库存
E2AM08KN04M1B1 数据手册
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance • Ensures a sensing distance approximately 1.5 to 2 times larger than that of any conventional OMRON Sensor. • Problems such as the collision of workpieces are eliminated. • Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels) • Modular construction simplifies customization. Ordering Information Size M8 Shielded Sensing distance 2.0 mm Connection Pre-wired Body material Stainless steel Thread length Output (overall length) configuration 27 (40) Stainless steel Brass PNP E2A-S08KS02-WP-B1 2M E2A-S08KS02-WP-B2 2M E2A-S08KS02-WP-C1 2M E2A-S08KS02-WP-C2 2M PNP E2A-S08LS02-WP-B1 2M E2A-S08LS02-WP-B2 2M NPN E2A-S08LS02-WP-C1 2M E2A-S08LS02-WP-C2 2M 27 (43) PNP E2A-S08KS02-M1-B1 E2A-S08KS02-M1-B2 NPN E2A-S08KS02-M1-C1 E2A-S08KS02-M1-C2 49 (65) PNP E2A-S08LS02-M1-B1 E2A-S08LS02-M1-B2 NPN E2A-S08LS02-M1-C1 E2A-S08LS02-M1-C2 27 (43) PNP E2A-M08KS02-M1-B1 E2A-M08KS02-M1-B2 NPN E2A-M08KS02-M1-C1 E2A-M08KS02-M1-C2 PNP E2A-M08LS02-M1-B1 E2A-M08LS02-M1-B2 NPN E2A-M08LS02-M1-C1 E2A-M08LS02-M1-C2 27 (39) PNP E2A-S08KS02-M5-B1 E2A-S08KS02-M5-B2 NPN E2A-S08KS02-M5-C1 E2A-S08KS02-M5-C2 49 (61) PNP E2A-S08LS02-M5-B1 E2A-S08LS02-M5-B2 NPN E2A-S08LS02-M5-C1 E2A-S08LS02-M5-C2 E2A-S08KN04-WP-B2 2M 49 (65) M8 connector (3- Stainless pin) steel Non-shielded 4.0 mm Pre-wired M12 connector Stainless steel Stainless steel Brass 27 (40) PNP E2A-S08KN04-WP-B1 2M NPN E2A-S08KN04-WP-C1 2M E2A-S08KN04-WP-C2 2M 49 (62) PNP E2A-S08LN04-WP-B1 2M E2A-S08LN04-WP-B2 2M NPN E2A-S08LN04-WP-C1 2M E2A-S08LN04-WP-C2 2M 27 (43) PNP E2A-S08KN04-M1-B1 E2A-S08KN04-M1-B2 NPN E2A-S08KN04-M1-C1 E2A-S08KN04-M1-C2 49 (65) PNP E2A-S08LN04-M1-B1 E2A-S08LN04-M1-B2 NPN E2A-S08LN04-M1-C1 E2A-S08LN04-M1-C2 27 (43) 49 (65) M8 connector (3- Stainless pin) steel Operation mode NC NPN 49 (62) M12 connector Operation mode NO 27 (39) 49 (61) PNP E2A-M08KN04-M1-B1 E2A-M08KN04-M1-B2 NPN E2A-M08KN04-M1-C1 E2A-M08KN04-M1-C2 PNP E2A-M08LN04-M1-B1 E2A-M08LN04-M1-B2 NPN E2A-M08LN04-M1-C1 E2A-M08LN04-M1-C2 PNP E2A-S08KN04-M5-B1 E2A-S08KN04-M5-B2 NPN E2A-S08KN04-M5-C1 E2A-S08KN04-M5-C2 PNP E2A-S08LN04-M5-B1 E2A-S08LN04-M5-B2 NPN E2A-S08LN04-M5-C1 E2A-S08LN04-M5-C2 E2A Cylindrical Proximity Sensor 1 Size M12 Sensing distance Shielded 4.0 mm Connection Pre-wired Body material Brass Thread length Output (overall length) configuration 34 (50) Non-shielded 8.0 mm Pre-wired Brass Brass PNP E2A-M12KS04-WP-B1 2M E2A-M12KS04-WP-B2 2M E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M PNP E2A-M12LS04-WP-B1 2M E2A-M12LS04-WP-B2 2M NPN E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M 34 (48) PNP E2A-M12KS04-M1-B1 E2A-M12KS04-M1-B2 NPN E2A-M12KS04-M1-C1 E2A-M12KS04-M1-C2 56 (70) PNP E2A-M12LS04-M1-B1 E2A-M12LS04-M1-B2 NPN E2A-M12LS04-M1-C1 E2A-M12LS04-M1-C2 PNP E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M NPN E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M 34 (50) 56 (72) M12 connector Brass 34 (48) 56 (70) M18 Shielded 8.0 mm Pre-wired Brass 39 (59) Non-shielded 16.0 mm Pre-wired Brass Brass Brass Shielded 15.0 mm Pre-wired Brass Non-shielded 20.0 mm Pre-wired Brass Brass 30.0 mm 20.0 mm M12 connector Brass 30.0 mm E2A-M12LN08-WP-C2 2M PNP E2A-M12KN08-M1-B1 E2A-M12KN08-M1-B2 NPN E2A-M12KN08-M1-C1 E2A-M12KN08-M1-C2 PNP E2A-M12LN08-M1-B1 E2A-M12LN08-M1-B2 NPN E2A-M12LN08-M1-C1 E2A-M12LN08-M1-C2 E2A-M18KS08-WP-B1 2M E2A-M18KS08-WP-B2 2M E2A-M18KS08-WP-C2 2M PNP E2A-M18LS08-WP-B1 2M E2A-M18LS08-WP-B2 2M NPN E2A-M18LS08-WP-C1 2M E2A-M18LS08-WP-C2 2M 39 (53) PNP E2A-M18KS08-M1-B1 E2A-M18KS08-M1-B2 NPN E2A-M18KS08-M1-C1 E2A-M18KS08-M1-C2 61 (75) PNP E2A-M18LS08-M1-B1 E2A-M18LS08-M1-B2 NPN E2A-M18LS08-M1-C1 E2A-M18LS08-M1-C2 PNP E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M NPN E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M 39 (59) 39 (53) 44 (64) PNP E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M NPN E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M PNP E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2 NPN E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2 PNP E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2 NPN E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2 PNP E2A-M30KS15-WP-B1 2M E2A-M30KS15-WP-B2 2M NPN E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C2 2M PNP E2A-M30LS15-WP-B1 2M E2A-M30LS15-WP-B2 2M NPN E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M 44 (58) PNP E2A-M30KS15-M1-B1 E2A-M30KS15-M1-B2 NPN E2A-M30KS15-M1-C1 E2A-M30KS15-M1-C2 66 (80) PNP E2A-M30LS15-M1-B1 E2A-M30LS15-M1-B2 NPN E2A-M30LS15-M1-C1 E2A-M30LS15-M1-C2 44 (64) (See note.) PNP E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M NPN E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M 66 (86) PNP E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2M 66 (86) M12 connector E2A-M12LN08-WP-B2 2M E2A-M12LN08-WP-C1 2M E2A-M18KS08-WP-C1 2M 61 (75) M30 E2A-M12LN08-WP-B1 2M PNP 61 (81) M12 connector PNP NPN NPN 61 (81) M12 connector Operation mode NC NPN 56 (72) M12 connector Operation mode NO NPN E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M 44 (58) (See note.) PNP E2A-M30KN20-M1-B1 E2A-M30KN20-M1-B2 NPN E2A-M30KN20-M1-C1 E2A-M30KN20-M1-C2 66 (80) PNP E2A-M30LN30-M1-B1 E2A-M30LN30-M1-B2 NPN E2A-M30LN30-M1-C1 E2A-M30LN30-M1-C2 Note: M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding metal. Standard sensing models are thus available. 2 E2A Cylindrical Proximity Sensor ■ Model Number Legend E2A@-@@@@@-@-@@-@@ 1 2 3 4 5 6 7 8 9 10 11 12 Example: E2A-M12LS04-M1-B1 E2A-M08KN04-WP-B1 5M Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m 1. Basic name E2A 2. Sensing technology Blank: Standard double distance 3. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel 4. Housing size 8. Kind of connection WP: Pre-wired, PVC M1: M12 connector (4-pole) M3: M8 connector (4-pole) M5: M8 connector (3-pole) 9. Power source and output B: DC, 3-wire, PNP open collector C: DC, 3-wire, NPN open collector 08: 8 mm D: DC, 2-wire 12: 12 mm E: DC, 3-wire, NPN voltage output 18: 18 mm F: DC, 3-wire, PNP voltage output 30: 30 mm 5. Barrel length 10.Operation mode 1: Normally open (NO) 2: Normally closed (NC) K: Standard length L: Long body 11.Specials (e.g., cable material, oscillating frequency) S: Shielded 12.Cable length N: Non-shielded 6. Shield 7. Sensing distance Blank: Connector type Numeral: Cable type Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm E2A Cylindrical Proximity Sensor 3 Specifications ■ DC 3-wire Models Size M8 Type Item M12 Shielded Non-shielded Shielded Non-shielded E2A-M08@S02-M1-B1 E2A-M08@S02-M1-B2 E2A-M08@S02-M1-C1 E2A-M08@S02-M1-C2 E2A-S08@S02-@@-B1 E2A-S08@S02-@@-B2 E2A-S08@S02-@@-C1 E2A-S08@S02-@@-C2 E2A-M08@N04-M1-B1 E2A-M08@N04-M1-B2 E2A-M08@N04-M1-C1 E2A-M08@N04-M1-C2 E2A-S08@N04-@@-B1 E2A-S08@N04-@@-B2 E2A-S08@N04-@@-C1 E2A-S08@N04-@@-C2 E2A-M12@S04-@@-B1 E2A-M12@S04-@@-B2 E2A-M12@S04-@@-C1 E2A-M12@S04-@@-C2 E2A-M12@N08-@@-B1 E2A-M12@N08-@@-B2 E2A-M12@N08-@@-C1 E2A-M12@N08-@@-C2 Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10% Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm 12×12×1 mm 24×24×1 mm Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz Power supply voltage (operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) Current consumption (DC 3-wire) 10 mA max. Output type -B models: PNP open collector -C models: NPN open collector Control output Load current (See note 2.) 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode (with sensing object approaching) -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Protection circuit Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Ambient air temperature Temperature influence (See note 2.) Ambient humidity Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s2, 10 times each in X, Y and Z directions Standard and listings (See note 3.) IEC60529: IP67, Degree of protection EN60947-5-2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Weight (packaged) Material 1,000 m/s2, 10 times each in X, Y and Z directions Pre-wired model Approx. 65 g Approx. 85 g M12 connector model M12 connector models: Approx. 20 g M8 connector models: Approx. 15 g Approx. 35 g Case Stainless steel or brass-nickel plated Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max., 3. For USA and CANADA : use class 2 circuit only. 4 E2A Cylindrical Proximity Sensor ■ DC 3-wire Models Size M18 Type Item M30 Shielded Non-shielded Shielded Non-shielded Non-shielded E2A-M18@S08-@@-B1 E2A-M18@S08-@@-B2 E2A-M18@S08-@@-C1 E2A-M18@S08-@@-C2 E2A-M18@N16-@@-B1 E2A-M18@N16-@@-B2 E2A-M18@N16-@@-C1 E2A-M18@N16-@@-C2 E2A-M30@S15-@@-B1 E2A-M30@S15-@@-B2 E2A-M30@S15-@@-C1 E2A-M30@S15-@@-C2 E2A-M30KN20-@@-B1 E2A-M30KN20-@@-B2 E2A-M30KN20-@@-C1 E2A-M30KN20-@@-C2 E2A-M30LN30-@@-B1 E2A-M30LN30-@@-B2 E2A-M30LN30-@@-C1 E2A-M30LN30-@@-C2 Sensing distance 8 mm±10% 16 mm±10% 15 mm±10% 20 mm±10% 30 mm±10% Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST37) 24×24×1 mm 48×48×1 mm 45×45×1 mm 60×60×1 mm 90×90×1 mm Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz 100 Hz Power supply voltage (operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) Current consumption (DC 3-wire) 10 mA max. Output type -B models: PNP open collector -C models: NPN open collector Control output Load current (See 200 mA max. (32 VDC max.) note 2.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode (with sensing object approaching) -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Ambient air temperature Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) Temperature influence (See ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C note 2.) ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C Ambient humidity Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions Standard and listings (See note 3.) IEC60529: IP67, Degree of protection EN60947-5-2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Weight (packaged) Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g M12 connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g Material Case Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max. 3. For USA and CANADA : use class 2 circuit only. E2A Cylindrical Proximity Sensor 5 Engineering Data Operating Range (Typical) Non-shielded Models 18 Sensing distance X (mm) Sensing distance X (mm) Shielded Models E2A-M30@S15 16 14 Y 12 X E2A-M18@S08 10 8 E2A-M12@S04 E2A-S08@S02/ E2A-M08@S02 6 4 35 E2A-M30LN30 30 Y 25 X E2A-M30KN20 20 E2A-M18@N16 15 E2A-M12@N08 10 E2A-S08@N04/ E2A-M08@N04 5 2 0 −30 −20 −10 0 10 20 0 −50 −40 −30 −20 −10 30 0 10 20 30 40 50 Distance Y (mm) Distance Y (mm) Influence of Sensing Object Size and Materials 2.5 @d X t = 1 mm Iron 2.0 Stainless steel (SUS303) 1.5 Brass 1.0 Aluminum E2A-M12@S04 E2A-M18@S08 Sensing distance X (mm) Sensing distance X (mm) E2A-S08@S02/M08@S02 Sensing distance X (mm) Shielded Models 5.0 @d X t = 1 mm Iron 4.0 Stainless steel (SUS303) 3.0 Brass Aluminum 2.0 Copper Copper 8.0 Iron 7.0 6.0 5.0 Brass 4.0 Aluminum 3.0 2.0 0.5 Stainless steel (SUS303) Copper @d X 1.0 t = 1 mm 1.0 0 5 10 15 20 25 Side length of sensing object d (mm) 0 5 Sensing distance X (mm) E2A-M30@S15 20 @d X t = 1 mm 16 Iron 12 Stainless steel (SUS303) 8 Brass Aluminum Copper 4 0 10 20 30 40 50 60 70 80 Side length of sensing object d (mm) 6 10 15 20 25 30 35 Side length of sensing object d (mm) E2A Cylindrical Proximity Sensor 0 10 20 30 40 50 60 Side length of sensing object d (mm) Non-shielded Models @d X E2A-M12@N08 t = 1 mm Iron 4.0 Stainless steel (SUS303) 3.0 Brass 2.0 Aluminum E2A-M18@N16 10 @d X t = 1 mm Iron 8 6 Stainless steel (SUS303) 4 Brass 20 30 40 0 50 t = 1 mm 10 20 30 Iron 12 Stainless steel (SUS303) Brass 8 40 50 0 20 40 60 80 Side length of sensing object d (mm) E2A-M30LN30 Sensing distance X (mm) E2A-M30KN20 Sensing distance X (mm) X 16 4 Side length of sensing object d (mm) Side length of sensing object d (mm) 25 @d Aluminum Copper Copper 2 10 20 Aluminum Copper 1.0 0 Sensing distance X (mm) 5.0 Sensing distance X (mm) Sensing distance X (mm) E2A-S08@N04/M08@N04 @d X t = 1 mm Iron 20 15 Stainless steel (SUS303) 10 Brass 35 @d 30 X Iron t = 1 mm 25 Stainless steel (SUS303) 20 Brass 15 Aluminum Copper Aluminum 10 Copper 5 5 0 20 40 60 80 100 Side length of sensing object d (mm) 0 20 40 60 80 100 Side length of sensing object d (mm) E2A Cylindrical Proximity Sensor 7 Operation ■ PNP Output Operation mode NO Model E2A-@-@-B1 Timing chart Non-sensing zone Output circuit Sensing zone Brown Proximity Sensor +V Sensing object (%) 100 Proximity Sensor main circuits 0 Black Rated sensing distance (See note 1.) Load ON OFF ON OFF Blue 0V Yellow indicator Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement 4 1 2 4 3 1 3 Note 2: Terminal 2 of the M12 connector is not used. NC E2A-@-@-B2 Non-sensing zone Sensing zone Brown Proximity Sensor +V Sensing object (%) 100 Black (M8 connector: Proximity Sensor main circuits 0 Rated sensing distance Load ON OFF Blue Yellow indicator ON OFF Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement 4 1 2 4 1 3 3 Note 2: Terminal 4 of the M12 connector is not used. 8 E2A Cylindrical Proximity Sensor ) (See note 1.) 0V ■ NPN Output Operation mode NO Model E2A-@-@-C1 Timing chart Non-sensing zone Output circuit Sensing zone Brown Proximity Sensor Sensing object (%) +V Load 100 Proximity Sensor main circuits 0 Rated sensing distance ON OFF ON OFF (See note 1.) Black Blue 0V Yellow indicator Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement 4 1 2 3 1 4 3 Note 2: Terminal 2 of the M12 connector is not used. NC E2A-@-@-C2 Non-sensing zone Sensing zone Brown Proximity Sensor Sensing object (%) +V Load 100 Proximity Sensor main circuits 0 Rated sensing distance ON OFF (M8 connector: ) Blue 0V Yellow indicator ON OFF (See note 1.) Black Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement 4 1 2 4 1 3 3 Note 2: Terminal 4 of the M12 connector is not used. E2A Cylindrical Proximity Sensor 9 Dimensions Note: All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) E2A-S08KS02-WP-@@ Pre-wired Models (Non-shielded) E2A-S08KN04-WP-@@ 40 40 27 3 13 13 5 27 3 6 5 6 dia. (See note 1.) Indicator (See note 2.) Two, clamping nuts M8×1 Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12KS04-WP-@@ (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12KN08-WP-@@ 50.3 50.3 34 4 34 17 4 17 7 7 7 9.4 dia. (See note 1.) Indicator (See note 2.) M12×1 (See note 1.) Indicator (See note 2.) M12×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M18KS08-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M18KN16-WP-@@ 59.5 59.5 39 4 24 10 24 10 39 4 10 15.3 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M18×1 M18×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30KS15-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30KN20-WP-@@ 64.5 64.5 44 44 5 36 15 36 10 5 10 26.6 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M30×1.5 M30×1.5 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) 10 E2A Cylindrical Proximity Sensor Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-S08LS02-WP-@@ E2A-S08LN04-WP-@@ 62 62 49 49 3 13 13 5 6 5 3 6 dia. (See note 1.) Indicator (See note 2.) M8×1 (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12LN08-WP-@@ E2A-M12LS04-WP-@@ 72.3 72.3 17 56 17 56 4 7 7 4 7 9.4 dia. (See note 1.) Indicator (See note 2.) M12×1 (See note 1.) Indicator (See note 2.) M12×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M18LN16-WP-@@ E2A-M18LS08-WP-@@ 81.5 61 81.5 61 24 4 24 4 10 10 10 15.3 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M18×1 M18×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30LN30-WP-@@ E2A-M30LS15-WP-@@ 86.5 86.5 66 66 5 36 15 36 5 10 10 26.6 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M30×1.5 Two, clamping nuts M30×1.5 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Mounting Hole Cutout Dimensions External diameter of Proximity Sensor Dimension F (mm) M8 M12 F +0.5 8.5 dia. 0 +0.5 0 12.5 dia. +0.5 0 M18 18.5 dia. M30 30.5 dia. +0.5 0 E2A Cylindrical Proximity Sensor 11 M12 Connector Models (Shielded) M12 Connector Models (Non-shielded) E2A-S08KN04-M1-@@ E2A-M08KN04-M1-@@ E2A-S08KS02-M1-@@ E2A-M08KS02-M1-@@ 43 43 27 3 27 3 13 5 13 M12×1 6 M12×1 5 6 dia. Indicator (See note.) Two, clamping nuts M8×1 Indicator (See note.) Two, clamping nuts M8×1 Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) E2A-M12KN08-M1-@@ E2A-M12KS04-M1-@@ 48 48 34 17 34 7 4 M12×1 17 4 7 7 M12×1 9.4 dia. Indicator (See note.) Indicator (See note.) M12×1 M12×1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) E2A-M18KN16-M1-@@ E2A-M18KS08-M1-@@ 53 53 39 10 4 24 39 4 10 24 10 M12×1 M12×1 15.3 dia. Indicator (See note.) Indicator (See note.) M18×1 M18×1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) E2A-M30KS15-M1-@@ E2A-M30KN20-M1-@@ 58 58 44 44 36 5 15 36 10 5 10 M12×1 M12×1 26.6 dia. Indicator (See note.) Indicator (See note.) M30×1.5 M30×1.5 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) 12 E2A Cylindrical Proximity Sensor Note: Operation indicator (yellow LED, 4×90°) E2A-S08LS02-M1-@@ E2A-M08LS02-M1-@@ E2A-S08LN04-M1-@@ E2A-M08LN04-M1-@@ 65 65 49 49 3 13 5 13 M12×1 M12×1 5 3 6 6 dia. Indicator (See note.) M8×1 Indicator (See note.) M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) 70 E2A-M12LS04-M1-@@ E2A-M12LN08-M1-@@ 56 70 56 4 17 7 7 17 M12×1 4 7 M12×1 9.4 dia. Indicator (See note.) Two, clamping nuts M12×1 Indicator (See note.) M12×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M18LS08-M1-@@ 75 Note: Operation indicator (yellow LED, 4×90°) 75 E2A-M18LN16-M1-@@ 61 61 24 4 10 24 10 10 4 M12×1 M12×1 15.3 dia. Indicator (See note.) Indicator (See note.) M18×1 M18×1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) 80 E2A-M30LN30-M1-@@ E2A-M30LS15-M1-@@ 80 66 10 5 15 36 10 5 36 66 M12×1 26.6 dia. Indicator (See note.) Indicator (See note.) M30×1.5 Two, clamping nuts M30×1.5 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) M8 Connector Models (Shielded) E2A-S08KS02-M5-@@ M8 Connector Models (Non-shielded) E2A-S08KN04-M5-@@ 39 39 27 27 3 13 5 6 13 M8×1 3 M8×1 5 6 dia. M8×1 M8×1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) E2A-S08LS02-M5-@@ E2A-S08LN04-M5-@@ 61 61 49 49 3 13 5 M8×1 6 13 3 5 M8×1 6 dia. M8×1 Note: Operation indicator (yellow LED, 4×90°) M8×1 Note: Operation indicator (yellow LED, 4×90°) E2A Cylindrical Proximity Sensor 13 Precautions ■ Safety Precautions Wiring Power Supply Be sure to wire the E2A and load correctly, otherwise it may be damaged. Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A may be damaged. The E2A’s short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2A in operation, otherwise it may damage internal elements. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. ■ Correct Use Power OFF Designing The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Effects of Surrounding Metal When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained. l Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. n m d dia. D l m (Unit: mm) Type Dimension M8 M12 M18 M30 Short barrel Shielded Nonshielded l 0 0 0 (See note 2.) 4.5 12 24 45 d --- --- 27 45 D 0 0 1.5 4 n 12 18 27 45 l 12 15 22 30 40 m 8 20 48 70 90 d 24 40 70 90 120 D 12 15 22 30 40 n 24 40 70 90 120 E2A Cylindrical Proximity Sensor Dimension M8 M12 M18 M30 Short Long barrel barrel Shielded Nonshielded Note 1. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of 1.5 mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 4 mm. 14 Type Long barrel 0 (See note 1.) m (Unit: mm) A 20 30 60 B 15 20 35 110 70 A 80 120 200 300 300 B 60 100 120 200 300 Wiring Maintenance and Inspection High-tension Lines Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Mounting Never disassemble or repair the Sensor. The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Environment Do not tighten the nut with excessive force. A washer must be used with the nut. Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Type M8 Torque Stainless steel type 9 Nm Brass type 4 Nm M12 30 Nm M18 70 Nm M30 180 Nm Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. E2A Cylindrical Proximity Sensor 15 OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 16 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROpE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu Cat. No. D096-D1-01B 12/13 Note: Specifications are subject to change. © 2013 Omron Electronics LLC Printed in U.S.A.
E2AM08KN04M1B1 价格&库存

很抱歉,暂时无法提供与“E2AM08KN04M1B1”相匹配的价格&库存,您可以联系我们找货

免费人工找货