Cylindrical Proximity Sensor
E2A
Safe Mounting with Greater
Sensing Distance
• Ensures a sensing distance approximately 1.5 to 2
times larger than that of any conventional OMRON
Sensor.
• Problems such as the collision of workpieces are
eliminated.
• Full range of standard sizes (M8, M12, M18 and
M30; both long and short barrels)
• Modular construction simplifies customization.
Ordering Information
Size
M8
Shielded
Sensing
distance
2.0 mm
Connection
Pre-wired
Body
material
Stainless
steel
Thread length
Output
(overall length) configuration
27 (40)
Stainless
steel
Brass
PNP
E2A-S08KS02-WP-B1 2M
E2A-S08KS02-WP-B2 2M
E2A-S08KS02-WP-C1 2M
E2A-S08KS02-WP-C2 2M
PNP
E2A-S08LS02-WP-B1 2M
E2A-S08LS02-WP-B2 2M
NPN
E2A-S08LS02-WP-C1 2M
E2A-S08LS02-WP-C2 2M
27 (43)
PNP
E2A-S08KS02-M1-B1
E2A-S08KS02-M1-B2
NPN
E2A-S08KS02-M1-C1
E2A-S08KS02-M1-C2
49 (65)
PNP
E2A-S08LS02-M1-B1
E2A-S08LS02-M1-B2
NPN
E2A-S08LS02-M1-C1
E2A-S08LS02-M1-C2
27 (43)
PNP
E2A-M08KS02-M1-B1
E2A-M08KS02-M1-B2
NPN
E2A-M08KS02-M1-C1
E2A-M08KS02-M1-C2
PNP
E2A-M08LS02-M1-B1
E2A-M08LS02-M1-B2
NPN
E2A-M08LS02-M1-C1
E2A-M08LS02-M1-C2
27 (39)
PNP
E2A-S08KS02-M5-B1
E2A-S08KS02-M5-B2
NPN
E2A-S08KS02-M5-C1
E2A-S08KS02-M5-C2
49 (61)
PNP
E2A-S08LS02-M5-B1
E2A-S08LS02-M5-B2
NPN
E2A-S08LS02-M5-C1
E2A-S08LS02-M5-C2
E2A-S08KN04-WP-B2 2M
49 (65)
M8 connector (3- Stainless
pin)
steel
Non-shielded
4.0 mm
Pre-wired
M12 connector
Stainless
steel
Stainless
steel
Brass
27 (40)
PNP
E2A-S08KN04-WP-B1 2M
NPN
E2A-S08KN04-WP-C1 2M
E2A-S08KN04-WP-C2 2M
49 (62)
PNP
E2A-S08LN04-WP-B1 2M
E2A-S08LN04-WP-B2 2M
NPN
E2A-S08LN04-WP-C1 2M
E2A-S08LN04-WP-C2 2M
27 (43)
PNP
E2A-S08KN04-M1-B1
E2A-S08KN04-M1-B2
NPN
E2A-S08KN04-M1-C1
E2A-S08KN04-M1-C2
49 (65)
PNP
E2A-S08LN04-M1-B1
E2A-S08LN04-M1-B2
NPN
E2A-S08LN04-M1-C1
E2A-S08LN04-M1-C2
27 (43)
49 (65)
M8 connector (3- Stainless
pin)
steel
Operation mode NC
NPN
49 (62)
M12 connector
Operation mode NO
27 (39)
49 (61)
PNP
E2A-M08KN04-M1-B1
E2A-M08KN04-M1-B2
NPN
E2A-M08KN04-M1-C1
E2A-M08KN04-M1-C2
PNP
E2A-M08LN04-M1-B1
E2A-M08LN04-M1-B2
NPN
E2A-M08LN04-M1-C1
E2A-M08LN04-M1-C2
PNP
E2A-S08KN04-M5-B1
E2A-S08KN04-M5-B2
NPN
E2A-S08KN04-M5-C1
E2A-S08KN04-M5-C2
PNP
E2A-S08LN04-M5-B1
E2A-S08LN04-M5-B2
NPN
E2A-S08LN04-M5-C1
E2A-S08LN04-M5-C2
E2A Cylindrical Proximity Sensor
1
Size
M12
Sensing
distance
Shielded
4.0 mm
Connection
Pre-wired
Body
material
Brass
Thread length
Output
(overall length) configuration
34 (50)
Non-shielded
8.0 mm
Pre-wired
Brass
Brass
PNP
E2A-M12KS04-WP-B1 2M
E2A-M12KS04-WP-B2 2M
E2A-M12KS04-WP-C1 2M
E2A-M12KS04-WP-C2 2M
PNP
E2A-M12LS04-WP-B1 2M
E2A-M12LS04-WP-B2 2M
NPN
E2A-M12LS04-WP-C1 2M
E2A-M12LS04-WP-C2 2M
34 (48)
PNP
E2A-M12KS04-M1-B1
E2A-M12KS04-M1-B2
NPN
E2A-M12KS04-M1-C1
E2A-M12KS04-M1-C2
56 (70)
PNP
E2A-M12LS04-M1-B1
E2A-M12LS04-M1-B2
NPN
E2A-M12LS04-M1-C1
E2A-M12LS04-M1-C2
PNP
E2A-M12KN08-WP-B1 2M
E2A-M12KN08-WP-B2 2M
NPN
E2A-M12KN08-WP-C1 2M
E2A-M12KN08-WP-C2 2M
34 (50)
56 (72)
M12 connector
Brass
34 (48)
56 (70)
M18
Shielded
8.0 mm
Pre-wired
Brass
39 (59)
Non-shielded
16.0 mm
Pre-wired
Brass
Brass
Brass
Shielded
15.0 mm
Pre-wired
Brass
Non-shielded
20.0 mm
Pre-wired
Brass
Brass
30.0 mm
20.0 mm
M12 connector
Brass
30.0 mm
E2A-M12LN08-WP-C2 2M
PNP
E2A-M12KN08-M1-B1
E2A-M12KN08-M1-B2
NPN
E2A-M12KN08-M1-C1
E2A-M12KN08-M1-C2
PNP
E2A-M12LN08-M1-B1
E2A-M12LN08-M1-B2
NPN
E2A-M12LN08-M1-C1
E2A-M12LN08-M1-C2
E2A-M18KS08-WP-B1 2M
E2A-M18KS08-WP-B2 2M
E2A-M18KS08-WP-C2 2M
PNP
E2A-M18LS08-WP-B1 2M
E2A-M18LS08-WP-B2 2M
NPN
E2A-M18LS08-WP-C1 2M
E2A-M18LS08-WP-C2 2M
39 (53)
PNP
E2A-M18KS08-M1-B1
E2A-M18KS08-M1-B2
NPN
E2A-M18KS08-M1-C1
E2A-M18KS08-M1-C2
61 (75)
PNP
E2A-M18LS08-M1-B1
E2A-M18LS08-M1-B2
NPN
E2A-M18LS08-M1-C1
E2A-M18LS08-M1-C2
PNP
E2A-M18KN16-WP-B1 2M
E2A-M18KN16-WP-B2 2M
NPN
E2A-M18KN16-WP-C1 2M
E2A-M18KN16-WP-C2 2M
39 (59)
39 (53)
44 (64)
PNP
E2A-M18LN16-WP-B1 2M
E2A-M18LN16-WP-B2 2M
NPN
E2A-M18LN16-WP-C1 2M
E2A-M18LN16-WP-C2 2M
PNP
E2A-M18KN16-M1-B1
E2A-M18KN16-M1-B2
NPN
E2A-M18KN16-M1-C1
E2A-M18KN16-M1-C2
PNP
E2A-M18LN16-M1-B1
E2A-M18LN16-M1-B2
NPN
E2A-M18LN16-M1-C1
E2A-M18LN16-M1-C2
PNP
E2A-M30KS15-WP-B1 2M
E2A-M30KS15-WP-B2 2M
NPN
E2A-M30KS15-WP-C1 2M
E2A-M30KS15-WP-C2 2M
PNP
E2A-M30LS15-WP-B1 2M
E2A-M30LS15-WP-B2 2M
NPN
E2A-M30LS15-WP-C1 2M
E2A-M30LS15-WP-C2 2M
44 (58)
PNP
E2A-M30KS15-M1-B1
E2A-M30KS15-M1-B2
NPN
E2A-M30KS15-M1-C1
E2A-M30KS15-M1-C2
66 (80)
PNP
E2A-M30LS15-M1-B1
E2A-M30LS15-M1-B2
NPN
E2A-M30LS15-M1-C1
E2A-M30LS15-M1-C2
44 (64)
(See note.)
PNP
E2A-M30KN20-WP-B1 2M
E2A-M30KN20-WP-B2 2M
NPN
E2A-M30KN20-WP-C1 2M
E2A-M30KN20-WP-C2 2M
66 (86)
PNP
E2A-M30LN30-WP-B1 2M
E2A-M30LN30-WP-B2 2M
66 (86)
M12 connector
E2A-M12LN08-WP-B2 2M
E2A-M12LN08-WP-C1 2M
E2A-M18KS08-WP-C1 2M
61 (75)
M30
E2A-M12LN08-WP-B1 2M
PNP
61 (81)
M12 connector
PNP
NPN
NPN
61 (81)
M12 connector
Operation mode NC
NPN
56 (72)
M12 connector
Operation mode NO
NPN
E2A-M30LN30-WP-C1 2M
E2A-M30LN30-WP-C2 2M
44 (58)
(See note.)
PNP
E2A-M30KN20-M1-B1
E2A-M30KN20-M1-B2
NPN
E2A-M30KN20-M1-C1
E2A-M30KN20-M1-C2
66 (80)
PNP
E2A-M30LN30-M1-B1
E2A-M30LN30-M1-B2
NPN
E2A-M30LN30-M1-C1
E2A-M30LN30-M1-C2
Note: M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from
the surrounding metal. Standard sensing models are thus available.
2
E2A Cylindrical Proximity Sensor
■ Model Number Legend
E2A@-@@@@@-@-@@-@@
1
2
3 4 5 6 7
8
9 10 11 12
Example: E2A-M12LS04-M1-B1
E2A-M08KN04-WP-B1 5M
Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m
1. Basic name
E2A
2. Sensing technology
Blank:
Standard double distance
3. Housing shape and material
M:
Cylindrical, metric threaded, brass
S:
Cylindrical, metric threaded, stainless steel
4. Housing size
8. Kind of connection
WP:
Pre-wired, PVC
M1:
M12 connector (4-pole)
M3:
M8 connector (4-pole)
M5:
M8 connector (3-pole)
9. Power source and output
B:
DC, 3-wire, PNP open collector
C:
DC, 3-wire, NPN open collector
08:
8 mm
D:
DC, 2-wire
12:
12 mm
E:
DC, 3-wire, NPN voltage output
18:
18 mm
F:
DC, 3-wire, PNP voltage output
30:
30 mm
5. Barrel length
10.Operation mode
1:
Normally open (NO)
2:
Normally closed (NC)
K:
Standard length
L:
Long body
11.Specials (e.g., cable material, oscillating frequency)
S:
Shielded
12.Cable length
N:
Non-shielded
6. Shield
7. Sensing distance
Blank:
Connector type
Numeral: Cable type
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
E2A Cylindrical Proximity Sensor
3
Specifications
■ DC 3-wire Models
Size
M8
Type
Item
M12
Shielded
Non-shielded
Shielded
Non-shielded
E2A-M08@S02-M1-B1
E2A-M08@S02-M1-B2
E2A-M08@S02-M1-C1
E2A-M08@S02-M1-C2
E2A-S08@S02-@@-B1
E2A-S08@S02-@@-B2
E2A-S08@S02-@@-C1
E2A-S08@S02-@@-C2
E2A-M08@N04-M1-B1
E2A-M08@N04-M1-B2
E2A-M08@N04-M1-C1
E2A-M08@N04-M1-C2
E2A-S08@N04-@@-B1
E2A-S08@N04-@@-B2
E2A-S08@N04-@@-C1
E2A-S08@N04-@@-C2
E2A-M12@S04-@@-B1
E2A-M12@S04-@@-B2
E2A-M12@S04-@@-C1
E2A-M12@S04-@@-C2
E2A-M12@N08-@@-B1
E2A-M12@N08-@@-B2
E2A-M12@N08-@@-C1
E2A-M12@N08-@@-C2
Sensing distance
2 mm ± 10%
4 mm ± 10%
4 mm ± 10%
8 mm ± 10%
Setting distance
0 to 1.6 mm
0 to 3.2 mm
0 to 3.2 mm
0 to 6.4 mm
Differential travel
10% max. of sensing distance
Target
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37)
8×8×1 mm
12×12×1 mm
12×12×1 mm
24×24×1 mm
Response frequency (See note 1.)
1,500 Hz
1,000 Hz
1,000 Hz
800 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 3-wire)
10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.)
200 mA max. (32 VDC max.)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Power source circuit reverse polarity protection,
Surge suppressor, Short-circuit protection
Ambient air temperature
Temperature influence (See note 2.)
Ambient humidity
Output reverse polarity protection, Power source
circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence
±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(packaged)
Material
1,000 m/s2, 10 times each in X, Y and Z directions
Pre-wired model
Approx. 65 g
Approx. 85 g
M12 connector model
M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g
Approx. 35 g
Case
Stainless steel or brass-nickel plated
Brass-nickel plated
Sensing surface
PBT
Cable
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and CANADA : use class 2 circuit only.
4
E2A Cylindrical Proximity Sensor
■ DC 3-wire Models
Size
M18
Type
Item
M30
Shielded
Non-shielded
Shielded
Non-shielded
Non-shielded
E2A-M18@S08-@@-B1
E2A-M18@S08-@@-B2
E2A-M18@S08-@@-C1
E2A-M18@S08-@@-C2
E2A-M18@N16-@@-B1
E2A-M18@N16-@@-B2
E2A-M18@N16-@@-C1
E2A-M18@N16-@@-C2
E2A-M30@S15-@@-B1
E2A-M30@S15-@@-B2
E2A-M30@S15-@@-C1
E2A-M30@S15-@@-C2
E2A-M30KN20-@@-B1
E2A-M30KN20-@@-B2
E2A-M30KN20-@@-C1
E2A-M30KN20-@@-C2
E2A-M30LN30-@@-B1
E2A-M30LN30-@@-B2
E2A-M30LN30-@@-C1
E2A-M30LN30-@@-C2
Sensing distance
8 mm±10%
16 mm±10%
15 mm±10%
20 mm±10%
30 mm±10%
Setting distance
0 to 6.4 mm
0 to 12.8 mm
0 to 12 mm
0 to 16 mm
0 to 24 mm
Differential travel
10% max. of sensing distance
Target
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
24×24×1 mm
48×48×1 mm
45×45×1 mm
60×60×1 mm
90×90×1 mm
Response frequency
(See note 1.)
500 Hz
400 Hz
250 Hz
100 Hz
100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC
3-wire)
10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current (See 200 mA max. (32 VDC max.)
note 2.)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit
protection
Ambient air temperature
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
note 2.)
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Ambient humidity
Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence
±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(packaged)
Pre-wired model
Approx. 160 g
Approx. 280 g
Approx. 280 g
Approx. 370 g
M12 connector
model
Approx. 70 g
Approx. 200 g
Approx. 200 g
Approx. 260 g
Material Case
Brass-nickel plated
Sensing surface
PBT
Cable
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and CANADA : use class 2 circuit only.
E2A Cylindrical Proximity Sensor
5
Engineering Data
Operating Range (Typical)
Non-shielded Models
18
Sensing distance X (mm)
Sensing distance X (mm)
Shielded Models
E2A-M30@S15
16
14
Y
12
X
E2A-M18@S08
10
8
E2A-M12@S04
E2A-S08@S02/
E2A-M08@S02
6
4
35
E2A-M30LN30
30
Y
25
X
E2A-M30KN20
20
E2A-M18@N16
15
E2A-M12@N08
10
E2A-S08@N04/
E2A-M08@N04
5
2
0
−30
−20
−10
0
10
20
0
−50 −40 −30 −20 −10
30
0
10
20
30
40
50
Distance Y (mm)
Distance Y (mm)
Influence of Sensing Object Size and Materials
2.5
@d
X
t = 1 mm
Iron
2.0
Stainless steel (SUS303)
1.5
Brass
1.0
Aluminum
E2A-M12@S04
E2A-M18@S08
Sensing distance X (mm)
Sensing distance X (mm)
E2A-S08@S02/M08@S02
Sensing distance X (mm)
Shielded Models
5.0
@d
X
t = 1 mm
Iron
4.0
Stainless steel
(SUS303)
3.0
Brass
Aluminum
2.0
Copper
Copper
8.0
Iron
7.0
6.0
5.0
Brass
4.0
Aluminum
3.0
2.0
0.5
Stainless steel (SUS303)
Copper
@d
X
1.0
t = 1 mm
1.0
0
5
10
15
20
25
Side length of sensing object d (mm)
0
5
Sensing distance X (mm)
E2A-M30@S15
20
@d
X
t = 1 mm
16
Iron
12
Stainless steel (SUS303)
8
Brass
Aluminum
Copper
4
0
10
20
30
40
50
60
70
80
Side length of sensing object d (mm)
6
10
15
20
25
30
35
Side length of sensing object d (mm)
E2A Cylindrical Proximity Sensor
0
10
20
30
40
50
60
Side length of sensing object d (mm)
Non-shielded Models
@d
X
E2A-M12@N08
t = 1 mm
Iron
4.0
Stainless steel (SUS303)
3.0
Brass
2.0
Aluminum
E2A-M18@N16
10
@d
X
t = 1 mm
Iron
8
6
Stainless steel (SUS303)
4
Brass
20
30
40
0
50
t = 1 mm
10
20
30
Iron
12
Stainless steel (SUS303)
Brass
8
40
50
0
20
40
60
80
Side length of sensing object d (mm)
E2A-M30LN30
Sensing distance X (mm)
E2A-M30KN20
Sensing distance X (mm)
X
16
4
Side length of sensing object d (mm)
Side length of sensing object d (mm)
25
@d
Aluminum
Copper
Copper
2
10
20
Aluminum
Copper
1.0
0
Sensing distance X (mm)
5.0
Sensing distance X (mm)
Sensing distance X (mm)
E2A-S08@N04/M08@N04
@d
X t = 1 mm
Iron
20
15
Stainless steel (SUS303)
10
Brass
35
@d
30
X
Iron
t = 1 mm
25
Stainless steel (SUS303)
20
Brass
15
Aluminum
Copper
Aluminum
10
Copper
5
5
0
20
40
60
80
100
Side length of sensing object d (mm)
0
20
40
60
80
100
Side length of sensing object d (mm)
E2A Cylindrical Proximity Sensor
7
Operation
■ PNP Output
Operation mode
NO
Model
E2A-@-@-B1
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
(%)
100
Proximity
Sensor
main
circuits
0
Black
Rated
sensing
distance
(See note 1.)
Load
ON
OFF
ON
OFF
Blue
0V
Yellow indicator
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
3
1
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-B2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
(%)
100
Black
(M8 connector:
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
Load
ON
OFF
Blue
Yellow indicator
ON
OFF
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
8
E2A Cylindrical Proximity Sensor
)
(See note 1.)
0V
■ NPN Output
Operation mode
NO
Model
E2A-@-@-C1
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Brown
Proximity
Sensor
Sensing
object
(%)
+V
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
OFF
ON
OFF
(See note 1.) Black
Blue
0V
Yellow indicator
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
3
1
4
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-C2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
Sensing
object
(%)
+V
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
OFF
(M8 connector:
)
Blue
0V
Yellow indicator
ON
OFF
(See note 1.) Black
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
E2A Cylindrical Proximity Sensor
9
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded)
E2A-S08KS02-WP-@@
Pre-wired Models (Non-shielded)
E2A-S08KN04-WP-@@
40
40
27
3
13
13
5
27
3
6
5
6 dia.
(See note 1.)
Indicator (See note 2.)
Two, clamping nuts
M8×1
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12KS04-WP-@@
(See note 1.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12KN08-WP-@@
50.3
50.3
34
4
34
17
4
17
7
7
7
9.4 dia.
(See note 1.)
Indicator (See note 2.)
M12×1
(See note 1.)
Indicator (See note 2.)
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18KS08-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18KN16-WP-@@
59.5
59.5
39
4
24
10
24
10
39
4
10
15.3 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30KS15-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30KN20-WP-@@
64.5
64.5
44
44
5
36
15
36
10
5
10
26.6 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M30×1.5
M30×1.5
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
10
E2A Cylindrical Proximity Sensor
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-S08LS02-WP-@@
E2A-S08LN04-WP-@@
62
62
49
49
3
13
13
5
6
5
3
6 dia.
(See note 1.)
Indicator (See note 2.)
M8×1
(See note 1.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12LN08-WP-@@
E2A-M12LS04-WP-@@
72.3
72.3
17
56
17
56
4
7
7
4
7
9.4 dia.
(See note 1.)
Indicator (See note 2.)
M12×1
(See note 1.)
Indicator (See note 2.)
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18LN16-WP-@@
E2A-M18LS08-WP-@@
81.5
61
81.5
61
24
4
24
4
10
10
10
15.3 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30LN30-WP-@@
E2A-M30LS15-WP-@@
86.5
86.5
66
66
5
36
15
36
5
10
10
26.6 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor Dimension F (mm)
M8
M12
F
+0.5
8.5 dia. 0
+0.5
0
12.5 dia.
+0.5
0
M18
18.5 dia.
M30
30.5 dia.
+0.5
0
E2A Cylindrical Proximity Sensor
11
M12 Connector Models (Shielded)
M12 Connector Models (Non-shielded)
E2A-S08KN04-M1-@@
E2A-M08KN04-M1-@@
E2A-S08KS02-M1-@@
E2A-M08KS02-M1-@@
43
43
27
3
27
3
13
5
13
M12×1
6
M12×1
5
6 dia.
Indicator (See note.)
Two, clamping nuts
M8×1
Indicator (See note.)
Two, clamping nuts
M8×1
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M12KN08-M1-@@
E2A-M12KS04-M1-@@
48
48
34
17
34
7
4
M12×1
17
4
7
7
M12×1
9.4 dia.
Indicator (See note.)
Indicator (See note.)
M12×1
M12×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M18KN16-M1-@@
E2A-M18KS08-M1-@@
53
53
39
10
4
24
39
4
10
24
10
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M30KS15-M1-@@
E2A-M30KN20-M1-@@
58
58
44
44
36
5
15
36
10
5
10
M12×1
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
M30×1.5
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
12
E2A Cylindrical Proximity Sensor
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LS02-M1-@@
E2A-M08LS02-M1-@@
E2A-S08LN04-M1-@@
E2A-M08LN04-M1-@@
65
65
49
49
3
13
5
13
M12×1
M12×1
5
3
6
6 dia.
Indicator (See note.)
M8×1
Indicator (See note.)
M8×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
70
E2A-M12LS04-M1-@@
E2A-M12LN08-M1-@@
56
70
56
4
17
7
7
17
M12×1
4
7
M12×1
9.4 dia.
Indicator (See note.)
Two, clamping nuts
M12×1
Indicator (See note.)
M12×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
E2A-M18LS08-M1-@@
75
Note: Operation indicator (yellow LED, 4×90°)
75
E2A-M18LN16-M1-@@
61
61
24
4
10
24
10
10
4
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
80
E2A-M30LN30-M1-@@
E2A-M30LS15-M1-@@
80
66
10
5
15
36
10
5
36
66
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
M8 Connector Models (Shielded)
E2A-S08KS02-M5-@@
M8 Connector Models (Non-shielded)
E2A-S08KN04-M5-@@
39
39
27
27
3
13
5
6
13
M8×1
3
M8×1
5
6 dia.
M8×1
M8×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LS02-M5-@@
E2A-S08LN04-M5-@@
61
61
49
49
3
13
5
M8×1
6
13
3
5
M8×1
6 dia.
M8×1
Note: Operation indicator (yellow LED, 4×90°)
M8×1
Note: Operation indicator (yellow LED, 4×90°)
E2A Cylindrical Proximity Sensor
13
Precautions
■ Safety Precautions
Wiring
Power Supply
Be sure to wire the E2A and load correctly, otherwise it may be damaged.
Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the E2A may be damaged.
The E2A’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2A in operation, otherwise it may damage internal elements.
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
■ Correct Use
Power OFF
Designing
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained.
l
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
n
m
d dia.
D
l
m
(Unit: mm)
Type
Dimension
M8
M12
M18
M30
Short
barrel
Shielded
Nonshielded
l
0
0
0
(See note 2.)
4.5
12
24
45
d
---
---
27
45
D
0
0
1.5
4
n
12
18
27
45
l
12
15
22
30
40
m
8
20
48
70
90
d
24
40
70
90
120
D
12
15
22
30
40
n
24
40
70
90
120
E2A Cylindrical Proximity Sensor
Dimension
M8
M12
M18
M30
Short Long
barrel barrel
Shielded
Nonshielded
Note 1. In the case of using the supplied nuts.
If true flash mounting is necessary, apply a free zone of
1.5 mm.
2. In the case of using the supplied nuts.
If true flush mounting is necessary, apply a free zone of
4 mm.
14
Type
Long
barrel
0
(See note
1.)
m
(Unit: mm)
A
20
30
60
B
15
20
35
110
70
A
80
120
200
300
300
B
60
100
120
200
300
Wiring
Maintenance and Inspection
High-tension Lines
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environmental conditions.
5. Check for proper lighting of indicators (for models with a set indicator.)
Mounting
Never disassemble or repair the Sensor.
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Environment
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the rain.
Operating Environment
Type
M8
Torque
Stainless steel type 9 Nm
Brass type
4 Nm
M12
30 Nm
M18
70 Nm
M30
180 Nm
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
E2A Cylindrical Proximity Sensor
15
OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of the products in
the customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product
for the systems, machines, and equipment with which it will be used.
Product specifications and accessories may be changed at any time
based on improvements and other reasons. Consult with your
OMRON representative at any time to confirm actual specifications
of purchased product.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
16
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
14.
15.
16.
17.
18.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for published information.
Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2.
3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS
Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROpE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • Tel: +31 (0) 23 568 13 00
Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu
Cat. No. D096-D1-01B
12/13
Note: Specifications are subject to change.
© 2013 Omron Electronics LLC
Printed in U.S.A.