E2EW-X22B1T30-M1

E2EW-X22B1T30-M1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON INDUSTRIAL AUTOMATION - E2EW-X22B1T30-M1 - PROXIMITY SENSOR, 22MM, PNP/SPST-NO, M30

  • 数据手册
  • 价格&库存
E2EW-X22B1T30-M1 数据手册
Welding Proximity Sensor E2EW Series DC 3-wire Stable detection in lines containing both aluminum and iron • Equivalent sensing distances for both iron and aluminum 1 • Enables common design for lines with both iron and aluminum 1 • The exceptional sensing range 2, which means fewer false detections and thereby fewer unexpected stoppages. • OMRON’s unique fluororesin coating technologies enable longlasting spatter resistance 4, eliminates the need to replace for 10 years 3. • Durable full metal body to reduce unexpected downtime • 2-output (NO+NC) models and models with IO-Link 1 are also available. • Laser printed information (sensing distance on the sensor head, model on the cable, and model on the metal part of the connector model) reduce errors during sensor replacement. 5 • Weld field immunity cancels pulse noise from magnetic fields. 1 • UL certification (UL60947-5-2) and CSA certification (CSA C22.2 UL60947-5-2-14) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 23. 1. PREMIUM Models only. 2. Based on November 2020 OMRON investigation. 3. This value assumes that the sensor operates 10 hours a day in an arc welding environment and is cleaned once a month (12 times a year). If our previous model (E2EF-Q) needs to be replaced once every 3 times it is cleaned, the E2EW-Q Proximity Sensor needs to be replaced once every 180 times it is cleaned. This means that there is no need to replace the E2EW-Q Proximity Sensor for 10 or more years. 4. Models with spatter-resistant coating only. 5. Models without spatter-resistant coating only. E2EW Series Model Number Legend DC 3-wire E2EW - (1) X (2) (3) (4) (5) (6) - (7) No. Type (1) Case (2) Sensing distance (3) (4) Output configuration Operation mode (8) Code Blank Q With spatter-resistant coating Number Sensing distance (Unit: mm) B PNP open collector C NPN open collector 1 Normally open (NO) 2 Normally closed (NC) 3 Normally open, Normally closed (NO+NC) Blank (5) (6) IO-Link baud rate Size D Connection method (8) Cable length Non IO-Link compliant COM2 (38.4kbps) T COM3 (230.4kbps) 12 M12 18 M18 30 M30 Blank (7) Meaning Without spatter-resistant coating M1 M1TJ Number M Pre-wired Models M12 Connector Models M12 Pre-wired Smartclick Connector Models Cable length Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number. Models are not available for all combinations of code numbers. 1 E2EW Series Ordering Information PREMIUM Model E2EW Series (Quadruple distance model) DC 3-wire [Refer to Dimensions on page 26.] Shielded 1 Size (Sensing distance) Connection method Pre-wired (2 m) 2 Operation mode M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-X7B1T12 2M E2EW-X7C112 2M NC E2EW-X7B212 2M E2EW-X7C212 2M E2EW-X7B3T12 2M E2EW-X7C312 2M NO E2EW-X7B1T12-M1TJ 0.3M E2EW-X7C112-M1TJ 0.3M NC E2EW-X7B212-M1TJ 0.3M E2EW-X7C212-M1TJ 0.3M E2EW-X7B3T12-M1TJ 0.3M E2EW-X7C312-M1TJ 0.3M NO E2EW-X7B1T12-M1 E2EW-X7C112-M1 NC E2EW-X7B212-M1 E2EW-X7C212-M1 NO+NC E2EW-X7B3T12-M1 E2EW-X7C312-M1 NO E2EW-X12B1T18 2M E2EW-X12C118 2M NC E2EW-X12B218 2M E2EW-X12C218 2M E2EW-X12B3T18 2M E2EW-X12C318 2M NO E2EW-X12B1T18-M1TJ 0.3M E2EW-X12C118-M1TJ 0.3M NC E2EW-X12B218-M1TJ 0.3M E2EW-X12C218-M1TJ 0.3M NO+NC E2EW-X12B3T18-M1TJ 0.3M E2EW-X12C318-M1TJ 0.3M NO E2EW-X12B1T18-M1 E2EW-X12C118-M1 NC E2EW-X12B218-M1 E2EW-X12C218-M1 NO+NC E2EW-X12B3T18-M1 E2EW-X12C318-M1 NO E2EW-X22B1T30 2M E2EW-X22C130 2M NC E2EW-X22B230 2M E2EW-X22C230 2M NO+NC NO+NC M18 (12 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-X22B3T30 2M E2EW-X22C330 2M NO E2EW-X22B1T30-M1TJ 0.3M E2EW-X22C130-M1TJ 0.3M NC E2EW-X22B230-M1TJ 0.3M E2EW-X22C230-M1TJ 0.3M NO+NC E2EW-X22B3T30-M1TJ 0.3M E2EW-X22C330-M1TJ 0.3M NO E2EW-X22B1T30-M1 E2EW-X22C130-M1 NC E2EW-X22B230-M1 E2EW-X22C230-M1 E2EW-X22B3T30-M1 E2EW-X22C330-M1 NO+NC M30 (22 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector NPN NO NO+NC M12 (7 mm) Model PNP NO+NC 1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X7B1T12 5M) Note: 1. Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-XD" (Example: E2EW-X7B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 2 E2EW Series PREMIUM Model E2EW Series (Triple distance model) DC 3-wire [Refer to Dimensions on page 26.] Shielded 1 Size (Sensing distance) Connection method Pre-wired (2 m) 2 Operation mode M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-X6B1T12 2M E2EW-X6C112 2M NC E2EW-X6B212 2M E2EW-X6C212 2M E2EW-X6B3T12 2M E2EW-X6C312 2M NO E2EW-X6B1T12-M1TJ 0.3M E2EW-X6C112-M1TJ 0.3M NC E2EW-X6B212-M1TJ 0.3M E2EW-X6C212-M1TJ 0.3M E2EW-X6B3T12-M1TJ 0.3M E2EW-X6C312-M1TJ 0.3M NO E2EW-X6B1T12-M1 E2EW-X6C112-M1 NC E2EW-X6B212-M1 E2EW-X6C212-M1 NO+NC E2EW-X6B3T12-M1 E2EW-X6C312-M1 NO E2EW-X10B1T18 2M E2EW-X10C118 2M NC E2EW-X10B218 2M E2EW-X10C218 2M E2EW-X10B3T18 2M E2EW-X10C318 2M NO E2EW-X10B1T18-M1TJ 0.3M E2EW-X10C118-M1TJ 0.3M NC E2EW-X10B218-M1TJ 0.3M E2EW-X10C218-M1TJ 0.3M NO+NC E2EW-X10B3T18-M1TJ 0.3M E2EW-X10C318-M1TJ 0.3M NO E2EW-X10B1T18-M1 E2EW-X10C118-M1 NC E2EW-X10B218-M1 E2EW-X10C218-M1 NO+NC E2EW-X10B3T18-M1 E2EW-X10C318-M1 NO E2EW-X20B1T30 2M E2EW-X20C130 2M NC E2EW-X20B230 2M E2EW-X20C230 2M NO+NC NO+NC M18 (10 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-X20B3T30 2M E2EW-X20C330 2M NO E2EW-X20B1T30-M1TJ 0.3M E2EW-X20C130-M1TJ 0.3M NC E2EW-X20B230-M1TJ 0.3M E2EW-X20C230-M1TJ 0.3M NO+NC E2EW-X20B3T30-M1TJ 0.3M E2EW-X20C330-M1TJ 0.3M NO E2EW-X20B1T30-M1 E2EW-X20C130-M1 NC E2EW-X20B230-M1 E2EW-X20C230-M1 E2EW-X20B3T30-M1 E2EW-X20C330-M1 NO+NC M30 (20 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector NPN NO NO+NC M12 (6 mm) Model PNP NO+NC 1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X6B1T12 5M) Note: 1. Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EWXD" (Example: E2EW-X6B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 3 E2EW Series PREMIUM Model E2EW-Q Series (Spatter-resistant Quadruple distance model) DC 3-wire [Refer to Dimensions on page 26.] Shielded 1 Size (Sensing distance) Connection method Pre-wired (2 m) 2 M12 (7 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 Operation mode M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-QX7B1T12 2M E2EW-QX7C112 2M NC E2EW-QX7B212 2M E2EW-QX7C212 2M NO+NC E2EW-QX7B3T12 2M E2EW-QX7C312 2M NO E2EW-QX7B1T12-M1TJ 0.3M E2EW-QX7C112-M1TJ 0.3M NC E2EW-QX7B212-M1TJ 0.3M E2EW-QX7C212-M1TJ 0.3M E2EW-QX7B3T12-M1TJ 0.3M E2EW-QX7C312-M1TJ 0.3M NO E2EW-QX7B1T12-M1 E2EW-QX7C112-M1 NC E2EW-QX7B212-M1 E2EW-QX7C212-M1 NO+NC E2EW-QX7B3T12-M1 E2EW-QX7C312-M1 NO E2EW-QX12B1T18 2M E2EW-QX12C118 2M NC E2EW-QX12B218 2M E2EW-QX12C218 2M E2EW-QX12B3T18 2M E2EW-QX12C318 2M NO E2EW-QX12B1T18-M1TJ 0.3M E2EW-QX12C118-M1TJ 0.3M NC E2EW-QX12B218-M1TJ 0.3M E2EW-QX12C218-M1TJ 0.3M E2EW-QX12B3T18-M1TJ 0.3M E2EW-QX12C318-M1TJ 0.3M NO E2EW-QX12B1T18-M1 E2EW-QX12C118-M1 NC E2EW-QX12B218-M1 E2EW-QX12C218-M1 NO+NC E2EW-QX12B3T18-M1 E2EW-QX12C318-M1 NO E2EW-QX22B1T30 2M E2EW-QX22C130 2M NC E2EW-QX22B230 2M E2EW-QX22C230 2M NO+NC NO+NC E2EW-QX22B3T30 2M E2EW-QX22C330 2M NO E2EW-QX22B1T30-M1TJ 0.3M E2EW-QX22C130-M1TJ 0.3M NC E2EW-QX22B230-M1TJ 0.3M E2EW-QX22C230-M1TJ 0.3M E2EW-QX22B3T30-M1TJ 0.3M E2EW-QX22C330-M1TJ 0.3M NO E2EW-QX22B1T30-M1 E2EW-QX22C130-M1 NC E2EW-QX22B230-M1 E2EW-QX22C230-M1 NO+NC E2EW-QX22B3T30-M1 E2EW-QX22C330-M1 NO+NC M30 (22 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector NPN NO NO+NC M18 (12 mm) Model PNP NO+NC 1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX7B1T12 5M) Note: 1. Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-QXD" (Example: E2EW-QX7B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 4 E2EW Series PREMIUM Model E2EW-Q Series (Spatter-resistant Triple distance model) DC 3-wire [Refer to Dimensions on page 26.] Shielded 1 Size (Sensing distance) Connection method Pre-wired (2 m) 2 M12 (6 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 Operation mode M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector Pre-wired (2 m) 2 E2EW-QX6B1T12 2M E2EW-QX6C112 2M NC E2EW-QX6B212 2M E2EW-QX6C212 2M NO+NC E2EW-QX6B3T12 2M E2EW-QX6C312 2M NO E2EW-QX6B1T12-M1TJ 0.3M E2EW-QX6C112-M1TJ 0.3M NC E2EW-QX6B212-M1TJ 0.3M E2EW-QX6C212-M1TJ 0.3M E2EW-QX6B3T12-M1TJ 0.3M E2EW-QX6C312-M1TJ 0.3M NO E2EW-QX6B1T12-M1 E2EW-QX6C112-M1 NC E2EW-QX6B212-M1 E2EW-QX6C212-M1 NO+NC E2EW-QX6B3T12-M1 E2EW-QX6C312-M1 NO E2EW-QX10B1T18 2M E2EW-QX10C118 2M NC E2EW-QX10B218 2M E2EW-QX10C218 2M E2EW-QX10B3T18 2M E2EW-QX10C318 2M NO E2EW-QX10B1T18-M1TJ 0.3M E2EW-QX10C118-M1TJ 0.3M NC E2EW-QX10B218-M1TJ 0.3M E2EW-QX10C218-M1TJ 0.3M E2EW-QX10B3T18-M1TJ 0.3M E2EW-QX10C318-M1TJ 0.3M NO E2EW-QX10B1T18-M1 E2EW-QX10C118-M1 NC E2EW-QX10B218-M1 E2EW-QX10C218-M1 NO+NC E2EW-QX10B3T18-M1 E2EW-QX10C318-M1 NO E2EW-QX20B1T30 2M E2EW-QX20C130 2M NC E2EW-QX20B230 2M E2EW-QX20C230 2M NO+NC NO+NC E2EW-QX20B3T30 2M E2EW-QX20C330 2M NO E2EW-QX20B1T30-M1TJ 0.3M E2EW-QX20C130-M1TJ 0.3M NC E2EW-QX20B230-M1TJ 0.3M E2EW-QX20C230-M1TJ 0.3M E2EW-QX20B3T30-M1TJ 0.3M E2EW-QX20C330-M1TJ 0.3M NO E2EW-QX20B1T30-M1 E2EW-QX20C130-M1 NC E2EW-QX20B230-M1 E2EW-QX20C230-M1 E2EW-QX20B3T30-M1 E2EW-QX20C330-M1 NO+NC M30 (20 mm) M12 Pre-wired Smartclick Connector (0.3 m) M12 Connector NPN NO NO+NC M18 (10 mm) Model PNP NO+NC NO+NC 1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX6B1T12 5M) Note: 1. Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-QXD" (Example: E2EW-QX6B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 5 E2EW Series BASIC Model E2EW Series (Single distance model) DC 3-wire [Refer to Dimensions on page 27.] Shielded Size (Sensing distance) Connection method Pre-wired (2 m) * M12 (2 mm) M12 Pre-wired Smartclick Connector (0.3 m) Pre-wired (2 m) * M18 (5 mm) M12 Pre-wired Smartclick Connector (0.3 m) Pre-wired (2 m) * M30 (10 mm) M12 Pre-wired Smartclick Connector (0.3 m) Operation mode Model PNP E2EW-X2B112 2M E2EW-X2C112 2M NC E2EW-X2B212 2M E2EW-X2C212 2M NO+NC E2EW-X2B312 2M E2EW-X2C312 2M NO E2EW-X2B112-M1TJ 0.3M E2EW-X2C112-M1TJ 0.3M NC E2EW-X2B212-M1TJ 0.3M E2EW-X2C212-M1TJ 0.3M NO+NC E2EW-X2B312-M1TJ 0.3M E2EW-X2C312-M1TJ 0.3M NO E2EW-X5B118 2M E2EW-X5C118 2M NC E2EW-X5B218 2M E2EW-X5C218 2M NO+NC E2EW-X5B318 2M E2EW-X5C318 2M NO E2EW-X5B118-M1TJ 0.3M E2EW-X5C118-M1TJ 0.3M NC E2EW-X5B218-M1TJ 0.3M E2EW-X5C218-M1TJ 0.3M NO+NC E2EW-X5B318-M1TJ 0.3M E2EW-X5C318-M1TJ 0.3M NO E2EW-X10B130 2M E2EW-X10C130 2M NC E2EW-X10B230 2M E2EW-X10C230 2M NO+NC E2EW-X10B330 2M E2EW-X10C330 2M NO E2EW-X10B130-M1TJ 0.3M E2EW-X10C130-M1TJ 0.3M NC E2EW-X10B230-M1TJ 0.3M E2EW-X10C230-M1TJ 0.3M NO+NC E2EW-X10B330-M1TJ 0.3M E2EW-X10C330-M1TJ 0.3M * Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X2B112 5M) Note: IO-Link is not supported for all types of BASIC Model. 6 NPN NO E2EW Series BASIC Model E2EW-Q Series (Spatter-resistant Single distance model) DC 3-wire [Refer to Dimensions on page 27.] Shielded Size (Sensing distance) Connection method Pre-wired (2 m) * M12 (2 mm) M12 Pre-wired Smartclick Connector (0.3 m) Pre-wired (2 m) * M18 (5 mm) M12 Pre-wired Smartclick Connector (0.3 m) Pre-wired (2 m) * M30 (10 mm) M12 Pre-wired Smartclick Connector (0.3 m) Operation mode Model PNP NPN NO E2EW-QX2B112 2M E2EW-QX2C112 2M NC E2EW-QX2B212 2M E2EW-QX2C212 2M NO+NC E2EW-QX2B312 2M E2EW-QX2C312 2M NO E2EW-QX2B112-M1TJ 0.3M E2EW-QX2C112-M1TJ 0.3M NC E2EW-QX2B212-M1TJ 0.3M E2EW-QX2C212-M1TJ 0.3M NO+NC E2EW-QX2B312-M1TJ 0.3M E2EW-QX2C312-M1TJ 0.3M NO E2EW-QX5B118 2M E2EW-QX5C118 2M NC E2EW-QX5B218 2M E2EW-QX5C218 2M NO+NC E2EW-QX5B318 2M E2EW-QX5C318 2M NO E2EW-QX5B118-M1TJ 0.3M E2EW-QX5C118-M1TJ 0.3M NC E2EW-QX5B218-M1TJ 0.3M E2EW-QX5C218-M1TJ 0.3M NO+NC E2EW-QX5B318-M1TJ 0.3M E2EW-QX5C318-M1TJ 0.3M NO E2EW-QX10B130 2M E2EW-QX10C130 2M NC E2EW-QX10B230 2M E2EW-QX10C230 2M NO+NC E2EW-QX10B330 2M E2EW-QX10C330 2M NO E2EW-QX10B130-M1TJ 0.3M E2EW-QX10C130-M1TJ 0.3M NC E2EW-QX10B230-M1TJ 0.3M E2EW-QX10C230-M1TJ 0.3M NO+NC E2EW-QX10B330-M1TJ 0.3M E2EW-QX10C330-M1TJ 0.3M * Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX2B112 5M) Note: IO-Link is not supported for all types of BASIC Model. 7 E2EW Series Accessories (Sold Separately) Sensor I/O Connectors (Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately as required. Round Water-resistant Connectors XS2 series Appearance Cable Specification Type Cable diameter (mm) Cable Connection Direction Straight Sockets on One Cable End M12 Connector 6 dia. Right-angle Straight type Straight (Socket)/ Straight (Plug) PVC robot cable Right-angle type 8 Socket and Plug on Cable Ends 6 dia. Cable length (m) Sensor I/O Connector model number 2 XS2F-M12PVC4S2M 5 XS2F-M12PVC4S5M 10 XS2F-M12PVC4S10M 2 XS2F-M12PVC4A2M 5 XS2F-M12PVC4A5M 10 XS2F-M12PVC4A10M 1 XS2W-D421-C81-F 2 XS2W-D421-D81-F 3 XS2W-D421-E81-F 5 XS2W-D421-G81-F 10 XS2W-D421-J81-F Right-angle (Socket)/ Right-angle (Plug) 2 XS2W-D422-D81-F 5 XS2W-D422-G81-F Straight (Socket)/ Right-angle (Plug) 2 XS2W-D423-D81-F 5 XS2W-D423-G81-F Right-angle (Socket)/ Straight (Plug) 2 XS2W-D424-D81-F 5 XS2W-D424-G81-F Applicable Proximity Sensor model number E2EW-X-M1 E2EW-QX-M1 E2EW-X-M1TJ E2EW-QX-M1TJ E2EW Series Ratings and Specifications PREMIUM Model E2EW Series (Quadruple/Triple distance model) E2EW-Q Series (Spatter-resistant Quadruple/Triple distance model) DC 3-wire Shielded Type Quadruple distance model Size Item M18 Triple distance model M30 M12 M18 M30 E2EW-(Q)X712 E2EW-(Q)X1218 E2EW-(Q)X2230 E2EW-(Q)X612 E2EW-(Q)X1018 E2EW-(Q)X2030 Sensing distance 7 mm ±10% 12 mm ±10% 22 mm ±10% 6 mm ±10% 10 mm ±10% 20 mm ±10% Setting distance 0 to 4.9 mm 0 to 8.4 mm 0 to 15.4 mm 0 to 4.2 mm 0 to 7.0 mm 0 to 14 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data on page 11.) Standard sensing object Iron, 21 × 21 × 1 mm Response frequency 1 2 Hz Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2 Current consumption 720 mW max. (Current consumption: 30 mA max. at power supply voltage of 24 V) Output configuration B Models: PNP open collector, C Models: NPN open collector Operation mode 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) Control output Model M12 Iron, 36 × 36 × 1 mm Iron, 66 × 66 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Load current 1-output models (B1,B2,C1,C2): 10 to 30 VDC, Class 2, 200 mA max. 2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max. Residual voltage 1-output models (B1,B2,C1,C2): 2 V max. (Load current: 200 mA, Cable length: 2 m) 2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m) Iron, 60 × 60 × 1 mm Indicator In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) Protection circuits Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection Ambient temperature range Operating: 0 to 85 °C, Storage: -15 to 85 °C (with no icing or condensation) 3 Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±20% max. of sensing distance at 23 °C in the temperature range of 0 to 85 °C Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529: IP67 Connection method Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models Weight (packed state) Materials Pre-wired Approx. 140 g Approx. 165 g Approx. 225 g Approx. 140 g Approx. 165 g Approx. 225 g M12 Pre-wired Smartclick Connector Approx. 70 g Approx. 100 g Approx. 160 g Approx. 70 g Approx. 100 g Approx. 160 g M12 Connector Approx. 60 g Approx. 75 g Approx. 135 g Approx. 60 g Approx. 75 g Approx. 135 g Case E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Sensing surface E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Sensing surface (Thickness) 0.4 mm Clamping nuts E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Toothed washers Zinc-plated iron Cable Main IO-Link functions 2 IO-Link specification 0.4 mm 0.5 mm 0.4 mm 0.4 mm 0.5 mm Vinyl chloride (PVC) Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset Ver.1.1 IO-Link Baud rate Communication 2 Data length specifications Minimum cycle time E2EW(-Q) XBT: COM3 (230.4 kbps), E2EW(-Q) XBD: COM2 (38.4 kbps) Accessories Instruction manual, Clamping nuts, Toothed washer PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) COM2: 2.3 ms, COM3: 1.0 ms 1. The response frequency is an average value. Factory setting: (timer function: ONOFF delay) 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 3. UL temperature rating is between 0 °C to 60 °C. 9 E2EW Series BASIC Model E2EW Series (Single distance model) E2EW-Q Series (Spatter-resistant Single distance model) DC 3-wire Shielded Type Single distance model Size Item Model M12 M18 M30 E2EW-(Q)X212 E2EW-(Q)X518 E2EW-(Q)X1030 Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10% Setting distance 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data on page 11.) Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Response frequency 1 100 Hz 80 Hz 40 Hz Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2 Current consumption 1-output models (B1, B2, C1, C2): 16 mA max. 2-output models (B3, C3): 20 mA max. Output configuration B Models: PNP open collector, C Models: NPN open collector Operation mode 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) Control output Load current 1-output models (B1, B2, C1, C2): 10 to 30 VDC, Class 2, 200 mA max. 2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max. Residual voltage 1-output models (B1, B2, C1, C2): 2 V max. (Load current: 200 mA, Cable length: 2 m) 2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m) Indicator Operation indicator (orange, lit) and communication indicator (green, not lit) Protection circuits Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection Ambient temperature range Operating: 0 to 85 °C, Storage: -15 to 85 °C (with no icing or condensation) 2 Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±20% max. of sensing distance at 23 °C in the temperature range of 0 to 85 °C Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529: IP67 Connection method Weight (packed state) Materials Accessories Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) Pre-wired Approx. 140 g Approx. 160 g Approx. 225 g M12 Pre-wired Smartclick Connector Approx. 70 g Approx. 95 g Approx. 160 g Case E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Sensing surface E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Sensing surface (Thickness) 0.8 mm Clamping nuts E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303)) Toothed washers Zinc-plated iron Cable Vinyl chloride (PVC) 0.8 mm 0.8 mm Instruction manual, Clamping nuts, Toothed washer 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. UL temperature rating is between 0 °C to 60 °C. 10 E2EW Series Engineering Data (Reference Value) Sensing Area PREMIUM Model Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded Sensing object: Aluminum 24 22 20 Y 18 X E2EW-(Q)X22@30 16 Distance X (mm) Distance X (mm) Sensing object: iron 24 22 X E2EW-(Q)X22@30 18 16 14 14 12 12 10 10 E2EW-(Q)X12@18 8 E2EW-(Q)X12@18 8 E2EW-(Q)X7@12 6 6 4 E2EW-(Q)X7@12 4 2 2 0 -35 Y 20 -30 -25 -20 -15 -10 -5 0 5 10 15 20 0 -35 25 30 35 Distance Y (mm) -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 Distance Y (mm) Triple distance model/ Spatter-resistant Triple distance model Shielded Sensing object: Aluminum 24 22 20 18 16 Y X E2EW-(Q)X20@30 14 24 22 Y X 20 18 E2EW-(Q)X20@30 16 14 12 12 10 10 8 E2EW-(Q)X10@18 6 E2EW-(Q)X10@18 8 6 E2EW-(Q)X6@12 4 2 0 -35 Distance X (mm) Distance X (mm) Sensing object: iron E2EW-(Q)X6@12 4 2 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 Distance Y (mm) 0 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 Distance Y (mm) BASIC Model Single distance model/ Spatter-resistant Single distance model Shielded Distance X (mm) Sensing object: iron 14 Y 12 X 10 E2EW-(Q)X10@30 8 6 4 E2EW-(Q)X5@18 2 0 -25 E2EW-(Q)X2@12 -20 -15 -10 -5 0 5 10 15 20 25 Distance Y (mm) 11 E2EW Series Influence of Sensing Object Size and Material PREMIUM Model Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded Size: M12 E2EW-(Q)X712 Size: M12 E2EW--(Q)X612 Distance X (mm) Distance X (mm) Triple distance model/ Spatter-resistant Triple distance model Shielded 10 Brass Iron 8 10 Brass Iron 8 6 6 Copper Aluminum @d Stainless steel (SUS304) X 2 Copper Aluminum 4 4 t=3mm @d Stainless steel (SUS304) 2 X 0 0 0 10 20 30 40 50 60 70 80 0 90 10 20 30 40 Side length of sensing object: d (mm) Size: M18 E2EW-(Q)X1218 50 60 70 80 90 Side length of sensing object: d (mm) Size: M18 E2EW-(Q)X1018 Distance X (mm) Distance X (mm) t=3mm 16 Brass Iron 14 12 14 Brass Aluminum 12 10 10 8 Aluminum 8 Copper Copper Iron 6 6 @d 4 X Stainless steel (SUS304) 2 0 10 20 30 40 50 60 70 80 90 0 10 20 30 50 60 Iron Brass 20 Aluminum 25 Brass 90 Iron 20 Aluminum Copper Copper 10 10 @d X Stainless steel (SUS304) 5 @d t=3mm 0 0 10 20 30 40 50 60 70 80 90 100 110 120 X Stainless steel (SUS304) 5 Side length of sensing object: d (mm) 12 80 15 15 0 70 Size: M30 E2EW-(Q)X2030 25 Distance X (mm) Distance X (mm) 40 t=3mm Side length of sensing object: d (mm) Side length of sensing object: d (mm) Size: M30 E2EW-(Q)X2230 X Stainless steel (SUS304) 2 0 0 @d 4 t=3mm 0 10 20 30 40 50 60 70 80 90 100 t=3mm 110 120 Side length of sensing object: d (mm) E2EW Series BASIC Model Single distance model/ Spatter-resistant Single distance model Shielded Distance X (mm) Size: M12 E2EW-(Q)X212 3 @d X Iron t=3mm 2 Brass 1 Stainless steel (SUS304) Copper Aluminum 0 0 10 20 30 40 50 60 70 80 90 Side length of sensing object: d (mm) Distance X (mm) Size: M18 E2EW-(Q)X518 8 @d 7 X t=3mm Iron 6 5 4 Stainless steel (SUS304) 3 2 Brass 1 0 Aluminum 0 10 20 30 40 50 60 70 80 90 Side length of sensing object: d (mm) Distance X (mm) Size: M30 E2EW-(Q)X1030 14 @d X 12 t=3mm Iron 10 Stainless steel (SUS304) 8 6 Brass 4 Aluminum 2 0 0 10 20 30 40 50 60 70 80 90 Side length of sensing object: d (mm) 13 E2EW Series Influence of Sensing Object Thickness and Material PREMIUM Model Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded Size: M12 E2EW-(Q)X712 Size: M12 E2EW-(Q)X612 Distance X (mm) Distance X (mm) Triple distance model/ Spatter-resistant Triple distance model Shielded 10 Aluminum Brass 8 6 10 Aluminum Brass 8 6 Iron Copper Copper 4 Iron 4 t t X Stainless steel (SUS304) 2 2 Sensing object size: 21 × 21 mm Sensing object size: 18 × 18 mm 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 15 1 2 3 4 5 6 7 8 Thickness of sensing object: t (mm) Brass 12 Iron 12 13 14 15 16 14 Brass 12 8 Copper Aluminum 8 Iron t 6 2 Sensing object size: 36 × 36 mm 0 0 5 10 15 t 20 Sensing object size: 30 × 30 mm 0 5 10 Distance X (mm) Brass 20 Iron 15 t 10 0 5 10 Brass 20 10 Sensing object size: 66 × 66 mm 0 25 Iron X Stainless steel (SUS304) 5 30 15 Copper Aluminum 20 Size: M30 E2EW-(Q)X2030 30 25 15 Thickness of sensing object: t (mm) Thickness of sensing object: t (mm) Size: M30 E2EW-(Q)X2230 X Stainless steel (SUS304) 4 X 2 Copper Aluminum 6 Stainless steel (SUS304) 4 Distance X (mm) 11 10 10 15 20 Thickness of sensing object: t (mm) 14 10 Size: M18 E2EW-(Q)X1018 16 14 9 Thickness of sensing object: t (mm) Distance X (mm Distance X (mm) Size: M18 E2EW-(Q)X1218 0 X Stainless steel (SUS304) Copper Aluminum t X Stainless steel (SUS304) 5 Sensing object size: 60 × 60 mm 0 0 5 10 15 20 Thickness of sensing object: t (mm) E2EW Series BASIC Model Single distance model/ Spatter-resistant Single distance model Shielded Distance X (mm) Size: M12 E2EW-(Q)X212 3 Iron t X 2 Stainless steel (SUS304) Sensing object size: 12 × 12 mm 1 Brass Copper Aluminum 0 0 5 10 15 20 Thickness of sensing object: t (mm) Distance X (mm) Size: M18 E2EW-(Q)X518 8 7 Iron 6 t 5 4 X Stainless steel (SUS304) Sensing object size: 18 × 18 mm 3 2 1 0 Brass 0 Aluminum 5 10 15 20 Thickness of sensing object: t (mm) Distance X (mm) Size: M30 E2EW-(Q)X1030 14 Iron 12 t 10 X Stainless steel (SUS304) 8 Sensing object size: 30 × 30 mm 6 4 Brass 2 0 0 Aluminum 5 10 15 20 Thickness of sensing object: t (mm) 15 E2EW Series Monitor Output vs. Sensing Distance PREMIUM Model Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded Triple distance model/ Spatter-resistant Triple distance model Shielded Size: M12 E2EW-(Q)X612 300 Detection level Detection level Size: M12 E2EW-(Q)X712 @d=21 mm t=3 mm 250 X 200 300 @d=18 mm t=3 mm 250 200 Aluminum Iron Iron 150 150 100 100 Stainless steel (SUS304) 50 0 2 0 Stainless steel (SUS304) 50 4 8 6 0 10 0 2 4 Size: M18 E2EW-(Q)X1218 10 8 6 Distance X (mm) Distance X (mm) Size: M18 E2EW-(Q)X1018 300 @d=36 mm t=3 mm 250 X Aluminum 200 Detection level Detection level X Aluminum 300 @d=30 mm t=3 mm 250 X Aluminum 200 Iron 100 100 Stainless steel (SUS304) 50 0 Iron 150 150 0 0 Stainless steel (SUS304) 50 5 10 15 0 5 10 Distance X (mm) Size: M30 E2EW-(Q)X2030 300 @d=66 mm t=3 mm 250 X Aluminum 200 Detection level Detection level Size: M30 E2EW-(Q)X2230 300 @d=60 mm t=3 mm 250 200 Iron 150 150 100 100 Stainless steel (SUS304) 50 Stainless steel (SUS304) 50 0 5 10 15 20 25 30 Distance X (mm) 16 X Aluminum Iron 0 15 Distance X (mm) 0 0 5 10 15 20 25 30 Distance X (mm) E2EW Series I/O Circuit Diagrams/Timing charts DC 3-wire PNP output PREMIUM Model Output circuit Operation mode Model IO-Link Communication mode (COM mode) When using the Sensor connected to IO-Link Master Unit Standard I/O mode (SIO mode) When using as a general IO-Link master DC10 to 30V Brown (1) +V NO E2EW-(Q)XB1 Proximity sensor main circuit +V Brown (1) Proximity sensor main circuit Black (4) OUT +V (1) C/Q Black (4) C/Q (4) Load 0V Blue (3) 0V Blue (3) 0V (3) DC10 to 30V Brown (1) +V NC E2EW-(Q)XB2 Proximity sensor main circuit --- Black (2) OUT Load Blue (3) 0V DC10 to 30V Brown (1) +V Black (4) NO+NC E2EW-(Q)XB3 Proximity sensor main circuit Brown (1) C/Q OUT1 Load White (2) OUT2 Load Blue (3) IO-Link master +V Proximity sensor main circuit Black (4) DO +V (1) C/Q (4) DI (2) White (2) 0V 0V Blue (3) 0V0V (3) In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less. Connector Pin Arrangement M12 Connector M12 Smartclick Connector 1 4 2 3 17 E2EW Series PNP output Timing chart Nonsensing area Output mode Operation mode 1 Unstable Sensing area Set position Excessive proximity judgment distance 7 Stable Sensing area ProximitySensor Sensing object Rated Sensing distance (%) 100 80 20 0 ON OFF ON OFF ON OFF NO Standard I/O mode (SIO mode) 2 ON OFF ON OFF ON OFF NC ON OFF ON OFF ON OFF ON OFF NO+NC Comunication indicator (green) : Always OFF Operation indicator (orange) Control output 3 Comunication indicator (green) : Always OFF Operation indicator (orange) Control output 3 ON delay Comunication indicator (green) : Always OFF Operation indicator (orange) NO 5 4 Control output 1 3 Control output 2 3 Operation indicator (orange) Control output (PD1_bit0) 3 Instability detection 6 (PD1_bit4) Excessive proximity detection (PD1_bit5) Flashing Comunication indicator (green) (1sec cycle) IO-Link Communication mode (COM mode) NC 5 4 ON OFF 1 0 1 0 1 0 Operation indicator (orange) Control output (PD1_bit0) 3 Instability detection 6 (PD1_bit4) Excessive proximity detection (PD1_bit5) Flashing (1sec cycle) Comunication indicator (green) NO+NC 5 4 ON OFF 1 0 1 0 1 0 1 0 Sensing Present object Not present ON OFF ON NC OFF NO Flashing (1sec cycle) Comunication indicator (green) ON OFF 1 0 1 0 1 0 3. The timer function of the control output can be set up by the IO-Link communications. (It is able to select ON delay, OFF delay, one-shot, or ONOFF delay function and select a timer time of 1 to 16,383ms (T).) Operation indicator (orange) Control output1 (PD1_bit0) 3 Control output2 (PD1_bit1) 3 Instability detection 6 (PD1_bit4) Excessive proximity detection (PD1_bit5) OFF delay Sensing Present object Not present T 1 0 1 0 One shot Sensing Present object Not present ON OFF ON NC OFF NO 1 0 1 0 ON 1 OFF 0 ON 1 NC OFF 0 T ONOFF delay Sensing Present object Not present T ON OFF ON NC OFF NO T 1 0 1 0 T T T T 4. The excessive proximity diagnosis function can be selected by the IOLink communications. 5. The instability detection diagnosis can be selected by the IO-Link communications. 6. The judgment time for the instability detection diagnosis can be selected by the IO-Link communications. (For the ON delay timer function, the setting can be selected from 0 (invalid), 10, 50, 100, 300, 500, or 1000 ms.) 7. The judgment distance of the excessive proximity diagnosis function can be selected by the IOLink communications. (The distance can be selected as a combination of the material of the object detected, such as iron, aluminum, or SUS and the judgment distance of approximately 10, 20, or 30%. However, it is not allowed to select a combination of aluminum and 10%.) Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file). Please contact your OMRON sales representative regarding assignment of data. 1. For models with IO-Link, the operation mode can be changed by the IO-Link communications. 2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode). 18 T NO T E2EW Series DC 3-wire PNP output Operation mode BASIC Model Model Timing chart Nonsensing area Output circuit Stable sensing area DC10 to 30V Brown (1) +V ProximitySensor Sensing object NO E2EW-(Q)XB1 Rated Sensing distance 100 (%) Proximity sensor main circuit 0 OUT Load ON Operation indicator OFF (orange) ON Control output OFF Nonsensing area Black (4) Blue (3) Stable sensing area 0V DC10 to 30V Brown (1) +V ProximitySensor Sensing object NC E2EW-(Q)XB2 Rated Sensing distance 100 (%) Proximity sensor main circuit 0 Black (2) OUT Load ON Operation indicator OFF (orange) ON Control output OFF Nonsensing area Blue (3) Stable sensing area DC10 to 30V Brown (1) +V ProximitySensor Sensing object Black (4) Rated Sensing distance NO+NC E2EW-(Q)XB3 (%) 100 0V 0 ON Operation indicator OFF (orange) ON Control output 1 OFF ON Control output 2 OFF Proximity sensor main circuit OUT1 Load White (2) OUT2 Load Blue (3) 0V Connector Pin Arrangement M12 Connector M12 Smartclick Connector 1 4 2 3 19 E2EW Series DC 3-wire NPN OUTPUT Operation mode PREMIUM Model Model Timing chart Output circuit Stable sensing area Nonsensing area DC10 to 30V Brown (1) +V ProximitySensor Sensing object NO E2EW-(Q)XC1 Load Rated Sensing distance (%) 100 Proximity sensor main circuit 0 ON Operation indicator OFF (orange) ON Control output OFF Nonsensing area OUT Black (4) Blue (3) Stable sensing area 0V DC10 to 30V Brown (1) +V ProximitySensor Sensing object Load NC E2EW-(Q)XC2 Rated Sensing distance (%) 100 Proximity sensor main circuit 0 ON Operation indicator OFF (orange) ON OFF Control output Nonsensing area OUT Black (2) Blue (3) Stable sensing area ProximitySensor DC10 to 30V Sensing object Brown (1) Load Rated Sensing distance NO+NC E2EW-(Q)XC3 (%) 100 M12 Connector M12 Smartclick Connector 1 4 2 3 20 +V Load Black (4) 0 ON Operation indicator OFF (orange) ON Control output 1 OFF ON Control output 2 OFF Connector Pin Arrangement 0V Proximity sensor main circuit OUT1 White (2) OUT2 Blue (3) 0V E2EW Series DC 3-wire BASIC Model NPN OUTPUT Operation mode Model Timing chart Nonsensing area Output circuit Stable sensing area DC10 to 30V Brown (1) +V ProximitySensor Sensing object Load NO E2EW-(Q)XC1 Rated Sensing distance 100 (%) Proximity sensor main circuit 0 ON Operation indicator OFF (orange) ON Control output OFF Nonsensing area OUT Black (4) Blue (3) Stable sensing area DC10 to 30V Brown (1) +V ProximitySensor Sensing object NC E2EW-(Q)XC2 Load Rated Sensing distance 100 (%) Proximity sensor main circuit 0 ON Operation indicator OFF (orange) ON Control output OFF Nonsensing area OUT Black (2) Blue (3) DC10 to 30V ProximitySensor Brown (1) (%) +V Load Rated Sensing distance E2EW-(Q)XC3 0V Stable sensing area Sensing object NO+NC 0V 100 Load Black (4) Proximity sensor main circuit 0 ON OFF ON OFF ON OFF OUT1 White (2) Operation indicator (orange) Control output 1 OUT2 Blue (3) 0V Control output 2 Connector Pin Arrangement M12 Connector M12 Smartclick Connector 1 4 2 3 21 E2EW Series Connections for Sensor I/O Connectors DC 3-Wire Proximity Sensor Types Output Operation mode Sensor I/O Connectors Model Model Connections 1 XS2 E2EW Series E2EW-(Q)XB1- M1TJ/M1 Main circuit NO 1 1 2 2 3 3 4 4 Brown (+) White (not connected) Blue (–) Black (Output) XS2 E2EW Series 2 NC E2EW-(Q)XB2-M1TJ/M1 Main circuit PNP 1 1 2 2 3 3 4 4 XS2 E2EW Series Main circuit E2EW-(Q)XB3-M1TJ/M1 XS2FM124M XS2W-D42-81-F DC 3-Wire (M12 Connector) NO E2EW-(Q)XC1-M1TJ/M1 1 1 2 2 3 3 4 4 Brown (+) White (Output 2) Blue (-) Black (Output 1) XS2 E2EW Series Main circuit NO+NC Brown (+) White (Output) Blue (-) Black (not connected) 1 1 2 2 3 3 4 4 Brown (+) White (not connected) Blue (-) Black (Output) XS2 E2EW Series NC E2EW-(Q)XC2-M1TJ/M1 Main circuit 2 NPN 1 1 2 2 3 3 4 4 XS2 E2EW-(Q)XC3-M1TJ/M1 Main circuit E2EW Series NO+NC Brown (+) White (Output) Blue (-) Black (not connected) 1 1 2 2 3 3 4 4 Brown (+) White (Output 2) Blue (-) Black (Output 1) 1. If the XS2W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug. 2. Different from Proximity Sensor wire colors. 22 E2EW Series Safety Precautions Be sure to read the precautions for all models in the website at: http://www.automation.omron.com/. Warning Indications Warning level WARNING Precautions for Safe Use Precautions for Correct Use Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols General prohibition Indicates the instructions of unspecified prohibited action. Caution, explosion Indicates the possibility of explosion under specific conditions. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Otherwise, explosion may result. Never use the product with an AC power supply. Precautions for Correct Use Do not use the product in any atmosphere or environment that exceeds the ratings. Operating Environment 1. Do not install the Sensor in the following locations. (1) Outdoor locations directly subject to sunlight, rain, snow, waterdroplets, or oil. (2) Locations subject to atmospheres with chemical vapors, inparticular solvents and acids. (3) Locations subject to corrosive gases. 2. The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. Please refer to the Precautions for Correct Use on the OMRON website (www.ia.omron.com) for typical measures. 3. Laying the Proximity Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit. 4. Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. 5. When turning on the power by influence of temperature environment, an outputmis-pulse sometimes occurs. After the sensor has passed for 300 msec after turning on, please use in the stable state. 6. The sensor is adjusted with a high degree of accuracy, so do not use in the environment with sudden temperature change. 7. Operation check is performed using an OMRON's IO-Link master. If using an IO-Link master from another company, perform the operation check in advance. 8. When connecting non IO-Link compliant models to the IO-Link master, use the SIO mode. 9. In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less. 10.The Sensor cannot be used embedded in where pressure is constantly applied to the sensing surface, such as hydraulic cylinders and hydraulic valves. Precautions for Safe Use The following precautions must be observed to ensure safe operation. 1. Do not use the product in environments subject to flammable or explosive gases. 2. Do not attempt to disassemble, repair, or modify the product. 3. Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in explosion or fire. 4. Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire. 5. If the power supply is connected directly without a load, the internal elements may explode or burn. 6. Dispose of the product according to applicable regulations (laws). 23 E2EW Series Design When the Proximity Sensor is mounted in metal, ensure that the minimum distances given in the following table are maintained. Influence of Surrounding Metal When mounting the Proximity Sensor, ensure that the minimum distances given in the following table are maintained. If you use a nut, only use the provided nut. And ensure that the minimum distances between the sensing surface and nut is bigger than the "L" given in the following table. Other non-ferrous metals affect sensor's performance in the same way as aluminum. Perform the operation check in advance. d dia. (Unit: mm) Embedded material: Iron Models d dia. Quadruple distance model *1 (Unit: mm) Mounting panel material: Iron Models Quadruple distance model Triple distance model Single distance model Model L d D m n E2EW-(Q)X712 4 30 4 28 36 E2EW-(Q)X1218 6 54 6 36 54 E2EW-(Q)X2230 8 90 8 66 90 E2EW-(Q)X612 4 30 4 24 36 E2EW-(Q)X1018 2 54 2 30 54 E2EW-(Q)X2030 0 30 0 60 90 E2EW-(Q)X212 0 12 0 8 40 E2EW-(Q)X518 0 18 0 20 60 E2EW-(Q)X1030 0 30 0 40 100 Triple distance model Single distance model Quadruple distance model Triple distance model Single distance model Model L d D m n E2EW-(Q)X712 12 70 12 28 70 E2EW-(Q)X1218 12 80 12 36 80 E2EW-(Q)X2230 16 120 16 66 120 E2EW-(Q)X612 12 70 12 24 70 E2EW-(Q)X1018 12 80 12 30 80 E2EW-(Q)X2030 16 120 16 60 120 E2EW-(Q)X212 12 70 12 8 70 E2EW-(Q)X518 12 80 12 20 80 E2EW-(Q)X1030 16 120 16 40 120 1. If you use the model E2EW-(Q)X2230, or E2EW-(Q)X2030, the panel thickness (t) is 3 mm or less. 24 Model d D m n 4 30 4 28 36 E2EW-(Q)X1218 6 54 6 36 54 E2EW-(Q)X2230 8 90 8 66 90 E2EW-(Q)X612 02 12 2 02 24 36 E2EW-(Q)X1018 0 18 0 30 54 E2EW-(Q)X2030 0 30 0 60 90 E2EW-(Q)X212 0 12 0 8 40 E2EW-(Q)X518 0 18 0 20 60 E2EW-(Q)X1030 0 30 0 40 100 *2. If the thickness of the mounting bracket (t) is less than 10 mm, be sure to install the Sensor so that l  2, d (dia.)  30, and D  2. Embedded material: Aluminum Models Quadruple distance model Mounting panel material: Aluminum Models l E2EW-(Q)X712 Triple distance model Single distance model l d D m n E2EW-(Q)X712 Model 12 70 12 28 70 E2EW-(Q)X1218 12 80 12 36 80 E2EW-(Q)X2230 16 120 16 66 120 E2EW-(Q)X612 12 70 12 24 70 E2EW-(Q)X1018 12 80 12 30 80 E2EW-(Q)X2030 16 120 16 60 120 E2EW-(Q)X212 12 70 12 8 70 E2EW-(Q)X518 12 80 12 20 80 E2EW-(Q)X1030 16 120 16 40 120 E2EW Series Mutual Interference A When installing two or more Proximity Sensors face-to-face or sidebyside, ensure that the minimum distances given in the following table are maintained. Mounting Tightening Force Do not tighten the nut with excessive force. A washer must be used with the nut. The tightening force must be the same or less than the figures in the following table. Tr B A (Unit: mm) Models Quadruple distance model Triple distance model Single distance model (Unit: N·m) Item Model A B Size Torque E2EW-(Q)X712 45 40 M12 20 (15) E2EW-(Q)X1218 80 60 M18 70 (35) E2EW-(Q)X2230 135 110 E2EW-(Q)X612 45 40 M30 180 (60) E2EW-(Q)X1018 80 60 E2EW-(Q)X2030 135 110 E2EW-(Q)X212 40 35 * Tighten the nut of the E2EW-Q to a torque in parentheses. Single distance model (Unit: N·m) E2EW-(Q)X518 65 60 Size Torque E2EW-(Q)X1030 110 100 M12 30 (15) Chips from Cutting Aluminum Normally, chips from cutting aluminum will not cause a detection signal to be output even if it adheres to or accumulates on the detection surface. In the following cases, however, a detection signal may be output. Remove the cutting chips in these cases. 1. If d ≥ 2/3D at the center of the detection surface where d is the cutting chip size and D is the detection surface size (Unit: mm) Model Quadruple distance model, Triple distance model Dimension D E2EW-(Q)X12 10 E2EW-(Q)X18 16 E2EW-(Q)X30 28 2.If the cutting chips are pressed down M18 70 (35) M30 180 (60) * Tighten the nut of the E2EW-Q to a torque in parentheses. Note: When mounting the Proximity Sensor, only use the provided nut. Do not use set screws. The Sensor may malfunction. d Cutting chips Detection surface D Pressed down Cutting chips 25 E2EW Series Dimensions (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors E2EW/E2EW-Q Series (Quadruple distance/Triple distance/Spatter-resistant Quadruple distance, Spatter-resistant Triple distance model) PREMIUM Model Pre-wired Model/ Pre-wired Connector Model M12 Connector Model B B C F D E C Indicators Standard I/O mode (SIO mode): Operation indicator (orange/ON), communication indicator (green/OFF) IO-Link Communication mode (COM mode): Operation indicator (orange/ON), comunication indicator (green/Flashing (1sec cycle)* Two clamping nuts * Models with IO-Link only. G A D H Toothed washer Pre-wired Model F M12×P1 Two clamping nuts Toothed washer A Pre-wired Connector Model (M1TJ) Indicators Standard I/O mode (SIO mode): Operation indicator (orange/ON), communication indicator (green/OFF) IO-Link Communication mode (COM mode): Operation indicator (orange/ON), comunication indicator (green/Flashing (1sec cycle)* * Models with IO-Link only. E G M12×P1 Models (Operation mode): Output configuration (B1, C1): NO (B2, C2): NC Vinyl-insulated round cable with 3 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 2 m (Operation mode): Output configuration (B3, C3): NO+NC Vinyl-insulated round cable with 4 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 2 m Models (Operation mode): Output configuration (B3, C3): NO+NC Vinyl-insulated round cable with 4 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 0.3 m Model A B C D E F G E2EW-(Q)X7 12(-M1TJ) M12P1 41.5 30 4 10 21 dia. 17 M18P1 41.5 30 4 13 29 dia. 24 M30P1.5 41.5 30 5 13 42 dia. 36 M12P1 41.5 30 4 10 21 dia. 17 M18P1 41.5 30 4 13 29 dia. 24 M30P1.5 41.5 30 5 13 42 dia. 36 Quadruple E2EW-(Q)X12 distance 18(-M1TJ) model E2EW-(Q)X22 30(-M1TJ) E2EW-(Q)X6 Triple distance model (Operation mode): Output configuration (B1, C1): NO (B2, C2): NC Vinyl-insulated round cable with 3 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length:0.3 m 12(-M1TJ) E2EW-(Q)X10 18(-M1TJ) E2EW-(Q)X20 30(-M1TJ) F 26 A B C D E F M12P1 54.4 --- 4 28 8 M18P1 54.4 32 4 28 11 29 dia. 24 M30P1.5 54.4 32 5 28 11 42 dia. 36 E2EW-(Q) X612-M1 M12P1 54.4 --- 4 28 8 E2EW-(Q) X1018M1 M18P1 54.4 32 4 28 11 29 dia. 24 E2EW-(Q) X2030M1 M30P1.5 54.4 32 5 28 11 42 dia. 36 E2EW-(Q) Quadruple X1218distance M1 model E2EW-(Q) X2230M1 Triple distance model Angle R of the Bending Wire Mounting Hole Dimensions Dimensions Model E2EW-(Q) X712-M1 F (mm) M12 12.5 dia. +0.5 0 M18 18.5 dia. +0.5 0 M30 30.5 dia. +0.5 0 10 mm Dimensions R (mm) M12 M18 R M30 18 G H 21 dia. 17 21 dia. 17 E2EW Series Dimensions (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors E2EW/E2EW-Q Series (Single distance model/Spatter-resistant Single distance model) BASIC Model Pre-wired Model/ Pre-wired Connector Model B C F D G E Operation indicator (orange) Two clamping nuts A Toothed washer Pre-wired Connector Model (M1TJ) Pre-wired Model M12×P1 (Operation mode): Output configuration (B1, C1): NO (B2, C2): NC Vinyl-insulated round cable with 3 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 2 m (Operation mode): Output configuration (B1, C1): NO (B2, C2): NC Vinyl-insulated round cable with 3 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 0.3 m (Operation mode): Output configuration (B3, C3): NO+NC Vinyl-insulated round cable with 4 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 2 m Models Single distance model Model (Operation mode): Output configuration (B3, C3): NO+NC Vinyl-insulated round cable with 4 conductors size: 6-dia. (Conductor cross section: 0.3 mm2 (AWG24), Insulator diameter: 1.05 mm), Standard length: 0.3 m A B C D E E2EW-(Q)X2 12(-M1TJ) M12P1 41.9 30.4 4 7 E2EW-(Q)X5 18(-M1TJ) M18P1 41.9 30.4 4 10 29 dia. 24 E2EW-(Q)X10 30(-M1TJ) M30P1.5 41.9 30.3 5 10 42 dia. 36 F G 21 dia. 17 Angle R of the Bending Wire Mounting Hole Dimensions Dimensions F F (mm) M12 12.5 dia. +0.5 0 M18 18.5 dia. +0.5 0 M30 30.5 dia. +0.5 0 10 mm Dimensions R (mm) M12 M18 R 18 M30 27 OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com OTHER OMRON LATIN AMERICA SALES +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime D122DI-E3-02 Note: Specifications are subject to change. © 2021 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
E2EW-X22B1T30-M1 价格&库存

很抱歉,暂时无法提供与“E2EW-X22B1T30-M1”相匹配的价格&库存,您可以联系我们找货

免费人工找货