E2Q6-N20F3-H

E2Q6-N20F3-H

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    PROXIMITY SENSOR 30MM INDUCTIVE

  • 数据手册
  • 价格&库存
E2Q6-N20F3-H 数据手册
Rectangular Proximity Sensor E2Q6 CSM_E2Q6_DS_E_1_1 Freely Change the Sensing Direction • Change between any of five sensing directions: front or 90° up, down, left, or right. • Four indicators show the operating status of the Sensor from many directions. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 4. Ordering Information Sensors [Refer to Dimensions on page 6] DC Models Shielded/ Unshielded Sensing distance Shielded Connection method Operation mode 20 mm Terminal block Unshielded 30 mm Model NPN output PNP output E2Q6-N20E3-H E2Q6-N20F3-H E2Q6-N30ME3-H E2Q6-N30MF3-H NO + NC Accessories (Sold Separately) Recommended Cable Gland (ST Type) (Manufactured by LAPP) Purchase a cable gland to maintain a water-resistant structure. Product number ST-M20 × 1.5 Color Screw size M20 × P1.5 Black Applicable cable outer diameter 7 to 13 dia. Dimensions (Unit: mm) 25 37 9 27.6 17 For details or to make purchases, contact your OMRON sales representative. 13.4 Note: A seal packing is not included. Applicable seal packing GPM20 Note: Purchase a seal packing to maintain water resistance. 1 E2Q6 Ratings and Specifications Shielding Item Model Shielded Unshielded E2Q6-N20†3-H E2Q6-N30M†3-H Sensing distance 20 mm ±10% 30 mm ±10% Set distance 0 to 16 mm 0 to 24 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on page 3.) Standard sensing object Iron, 60 × 60 × 1 mm Iron, 90 × 90 × 1 mm Response frequency *1 150 Hz 100 Hz Power supply voltage (operating voltage range) 10 to 30 VDC, including 10% ripple (p-p) Current consumption Control output 20 mA max. Load current 200 mA max. Residual voltage 2 V max. (at 200 mA load current) Indicators Power indicator (green), detection indicator (yellow) Operation mode NO + NC Protection circuits Power supply reverse polarity protection, output reverse polarity protection, and load short-circuit protection Ambient temperature range Operating and storage: −25 to 70°C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 95% (with no condensation) Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence ±2% max. of sensing distance at 24 VDC in the range of 24 VDC ±15% ±2% max. of sensing distance at 12 VDC in the range of 12 VDC ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, at 50/60 Hz for 1 min. between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude in X, Y, and Z directions Shock resistance (destruction) 300 m/s2 3 times each in six directions Degree of protection IEC IP67 *2 Connection method Terminal block Weight (packed state/Sensor only) Approx. 250 g/approx. 230 g Materials Accessories Case Polyamide (PA) Sensing surface Polyamide (PA) Terminal base Polyamide (PA) Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. When the recommended cable gland is used. 2 E2Q6 Engineering Data (Reference Value) Sensing Area Shielded Models E2Q6-N20†3-H Unshielded Models E2Q6-N30M†3-H Y X 30 35 Distance X (mm) Distance X (mm) 35 25 30 25 Y X 20 20 15 15 10 10 5 5 0 −40 −30 −20 −10 0 10 20 30 0 −40 40 −30 −20 Distance Y (mm) Sensing Head −10 0 10 20 30 40 Distance Y (mm) Sensing Head 25 t = 1 mm d X Iron 20 Distance X (mm) Distance X (mm) Influence of Sensing Object Size and Materials Shielded Models Unshielded Models E2Q6-N20†3-H E2Q6-N30M†3-H 35 d t = 1 mm X Iron 30 Stainless steel SUS304 25 Stainless steel SUS304 15 20 15 10 Brass Brass Aluminum Aluminum 10 Copper Copper 5 5 0 0 0 10 20 30 40 50 60 0 70 10 20 Side length of sensing object: d (mm) 30 40 50 60 70 Side length of sensing object: d (mm) I/O Circuit Diagrams NPN Model Operation mode Timing charts Outside of sensing area Output circuit Sensing area Proximity Sensor Sensing object 1 +V Load Load 4 E2Q6-N20E3-H E2Q6-N30ME3-H 100 (%) 0 Rated sensing distance NO + NC NO output Proximity Sensor main circuit Lit Not lit ON OFF ON 2 NC output Detection indicator (yellow) Control output, NO 3 0V Terminal arrangement Cable connecting side Control output, NC OFF PNP Model Operation mode Timing charts Outside of sensing area Sensing area Output circuit Proximity Sensor 1 Sensing object E2Q6-N20F3-H E2Q6-N30MF3-H (%) NO + NC 100 Proximity Sensor main circuit 0 Rated sensing distance Lit Detection indicator Not lit (yellow) ON Control output, NO OFF ON +V NO output 4 NC output 2 Load Load 3 0V Terminal arrangement Cable connecting side Control output, NC OFF 3 E2Q6 Safety Precautions Be sure to read the precautions for all models in the website at: http//www.ia.omron.com/. Indication and Meaning for Safe Use WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, or undesirable effect on product performance. WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. Never use this product with an AC power supply. Otherwise, explosion may result. Precautions for Safe Use The following precautions must be observed to ensure safe operation. 1. Do not use the product in an environment where flammable or explosive gas is present. 2. Do not attempt to disassemble, repair, or modify the product. 3. Power Supply Voltage Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in damage or burnout. 4. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or burnout. 5. Connection without a Load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. 6. Dispose of this product as industrial waste. Precautions for Correct Use Operating Environment 1. Do not install the product in the following locations. Doing so may result in product failure or malfunction. (1) Outdoor locations directly subject to sunlight, rain, snow, water droplets, or oil. (2) Locations subject to atmospheres with chemical vapors, in particular solvents and acids. (3) Locations subject to corrosive gases. (4) Locations subject to shocks or vibration. 2. The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a highfrequency electric field. Please refer to the Precautions for Correct Use of Photoelectric Sensors on the OMRON website (www.ia.omron.com) for typical measures. 3. Laying the Proximity Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit. 4. Cleaning Never use thinner or other solvents. Otherwise, the product surface may be dissolved. 5. Do not subject the Sensor to strong shock. Otherwise, the Sensor Head may be damaged. Power ON The Sensor is ready to sense an object within 300 ms after turning the power ON. If the load and Sensor are connected to different power supplies, always turn ON the Sensor power first. Power OFF Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply to the load or load line first. Effects of Surrounding Metals When the Proximity Sensor is embedded in metal, make sure that the clearances given in the following table are maintained. UL Certification This product is certified for UL standards, but the certification is not applicable to metal piping to the conduit section. For UL applications, use a certified cable grip. B B C A F E E D (Unit: mm) Model A B C D E F E2Q6-N20…3-H 0 0 0 0 10 60 E2Q6-N30M…3-H 40 0 25 40 20 90 4 E2Q6 Mutual Interference Switching the Sensing Direction If more than one Proximity Sensor is installed face-to-face or side-byside, make sure that the distances between two units adjacent to each other are the same as or larger than the corresponding values shown in the following table. 1. Remove two screws. B A 2. Lifting the sensing surface separates it from the case. ② A (Unit: mm) Model A B E2Q6-N20…3-H 170 120 E2Q6-N30M…3-H 280 200 Tightening Torque Tighten bolts and screws with the specified torque. Between case and terminal 1.8 N·m Terminal screws 1.0 N·m ① 3. When positioning the sensing surface to the side, rotate it to the required position, then fit it into the case. (The possible positions are 0, 90, 180, and 270°. Do not forcefully rotate the sensing surface.) 4. Secure it with the screws. 5 E2Q6 (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors E2Q6-N20E3-H E2Q6-N20F3-H E2Q6-N30ME3-H E2Q6-N30MF3-H Power indicator (green) Two, 5.3-dia. holes Two, 7.3 Two, 5.3 30 40 Detection indicator (yellow) 60 46 Front Detection 118 40 Conduit screw, M20 × P1.5 40 11 16.3 40 Detection indicator (yellow) Power indicator (green) Mounting Hole Dimensions Four, 5.5-dia. (or M5) holes 30±0.2 60±0.2 6
E2Q6-N20F3-H 价格&库存

很抱歉,暂时无法提供与“E2Q6-N20F3-H”相匹配的价格&库存,您可以联系我们找货

免费人工找货
E2Q6-N20F3-H
  •  国内价格 香港价格
  • 1+2818.652311+365.80963

库存:0

E2Q6-N20F3-H
  •  国内价格 香港价格
  • 1+1177.089261+152.76470
  • 5+1097.769175+142.47040
  • 10+1024.9792710+133.02360

库存:6

E2Q6-N20F3-H

库存:4

E2Q6-N20F3-H
    •  国内价格
    • 1+1956.80164

    库存:4