0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E3FZ-LS66H

E3FZ-LS66H

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    HORIZ,BGS,100MM,NPN

  • 数据手册
  • 价格&库存
E3FZ-LS66H 数据手册
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 1 Dienstag, 15. April 2008 5:17 17 Easy mounting photoelectric sensor in short M18 housing E3FZ/E3FR • Secure-click snap mounting for fast installation • High power LED for enhanced sensing distance • Short housing with less than 40 mm length • Minimal optical axis deviation for easy alignment Features Easy and fast installation Installation time can be reduced by up to 10 times compared to conventional sensors. Up to 10 times faster Up to 3 times faster The SecureClick snap mounting mechanism provides easy installation in 2 steps and enhanced protection against vibration. >>CLICK 2 1 Conventional square sensors Conventional cylindrical sensors E3FZ with SecureClick* *SecureClick has been tested to withstand severe vibrations. E3FZ/E3FR 1 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 2 Dienstag, 15. April 2008 5:17 17 Ordering Information Snap mounting – E3FZ*2 Sensor type Through-beam Retroreflective with M.S.R. Diffuse reflective Diffuse reflective (background suppression) Sensing distance 15 m 0.1 to 4 m *1 1 m (adjustable) 100 mm (fixed) Connection method Order code NPN output PNP output – – 2m –*3 E3FZ-T61H 2M E3FZ-T81H 2M – „ – –*3 E3FZ-T66H E3FZ-T86H – – 2m –*3 E3FZ-R61H 2M E3FZ-R81H 2M – „ – –*3 E3FZ-R66H E3FZ-R86H – – 2m –*3 E3FZ-D62 2M E3FZ-D82 2M – „ – –*3 E3FZ-D67 E3FZ-D87 – – 2m –*3 E3FZ-LS61H 2M E3FZ-LS81H 2M – „ – –*3 E3FZ-LS66H E3FZ-LS86H – – 2m –*3 E3FZ-LS64H 2M E3FZ-LS84H 2M – „ – –*3 E3FZ-LS69H E3FZ-LS89H 200 mm (fixed) Radial mounting – E3FR Sensor type Through-beam Retroreflective with M.S.R. Diffuse reflective Diffuse reflective (background suppression) Sensing distance 15 m 0.1 to 4 m *1 1 m (adjustable) 100 mm (fixed) Connection method Order code *2. *3. 2 PNP output – – 2m –*3 E3FR-T61H 2M E3FR-T81H 2M – „ – –*3 E3FR-T66H E3FR-T86H – – 2m –*3 E3FR-R61H 2M E3FR-R81H 2M – „ – –*3 E3FR-R66H E3FR-R86H – – 2m –*3 E3FR-D62 2M E3FR-D82 2M – „ – –*3 E3FR-D67 E3FR-D87 – – 2m –*3 E3FR-LS61H 2M E3FR-LS81H 2M – „ – –*3 E3FR-LS66H E3FR-LS86H – – 2m –*3 E3FR-LS64H 2M E3FR-LS84H 2M – „ – –*3 E3FR-LS69H E3FR-LS89H 200 mm (fixed) *1. NPN output Measured with reflector E39-R1S The reflector is sold separately. Mounting with Snap-Holder (provided with product) or M18 Nuts (provided with product) possible. Pre-wired connectors are available on request (item description see "Model Number Legend" on page 4) Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 3 Dienstag, 15. April 2008 5:17 17 Accessories Reflectors Shape Type Material Features Size in mm Applicable Sensor General purpose reflectors - ABS base - Acrylic surface Surface screw mounting (diagonal holes) 59.9x40.3x7.5 Snap mounting dia 30 mm (reflector) dia 6.5 mm (snap mount) E39-R1S - Retroreflective photo electric sensors – non polarizing - Retroreflective photo electric sensors – polarizing (MSR) E39-R49 Order code Mounting brackets Shape Type Material Features Applicable Sensor Order code General purpose mounting stainless steel Horizontal angle adjustment E3FZ (dia 20mm snap holder) E39-EL8 Telescope mounting 3D rotation (fits to 12 mm mounting rod) E39-EL9 Sensor I/O connectors Straight 2m 4-wire 5m L-shaped 2m 5m PVC XS2F-D421-D80-A PUR Y92E-M12PUR4S2M-L PVC XS2F-D421-G80-A PUR Y92E-M12PUR4S5M-L PVC XS2F-D422-D80-A PUR Y92E-M12PUR4A2M-L PVC XS2F-D422-G80-A PUR Y92E-M12PUR4A5M-L Note: For the complete list of sensor I/O connectors refer to E26E Accessories datasheet. E3FZ/E3FR 3 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 4 Donnerstag, 15. Mai 2008 4:30 16 Model Number Legend E3F@-@@@@-@-@@ 1 2 3456 7 8 9 e.g., E3FZ-T81H; short housing/ through-beam/PNP output/2 m cable/without an adjustor/L-on/D-on by wire/ E3FZ-T86H-D; short housing/through-beam/PNP output/M12 connector/without an adjustor/L-on/D-on by wire/receiver E3FR-LS86; radial housing/background-suppression/PNP output/M12 connector/sensing distance of 100 mm/without an adjustor/ L-on/D-on by wire/ 1. Cylindrical family name: E3F 2. Series name 2: standard housing (seperate naming rule) Z: short housing R: radial housing 3. Sensing method T: through-beam R: retroreflective D: diffuse reflective LS: background suppression 4. Output 6: NPN output 8: PNP output 5. Connection Through-beam, retroreflective types 1: 2 m cable 6: M12 connector Diffuse reflective types 2: 2 m cable 7: M12 connector Background suppression types 1: 2 m cable/sensing distance of 100 mm 4: 2 m cable/sensing distance of 200 mm 6: M12 connector/sensing distance of 100 mm 9: M12 connector/sensing distance of 200 mm 4 6. Adjuster Blank: with volume adjuster/L-on/D-on by wire H: without volume adjuster/L-on/D-on by wire 7. Emitter/ Receiver L: emitter D: receiver 8. Kind of connection Blank: standard 2 m cable or M12 connector M1J: pre-wired with 30 cm cable and M12 plug connector (4 pin) M3J: pre-wired with 30 cm cable and M8 plug connector (4 pin) M5J: pre-wired with 30 cm cable and M8 plug connector (3 pin) M1TJ: pre-wired with 30cm cable and Twist&Click M12 plug connector (4 pin) 9. Cable length Blank: M12 connector Number: cable length Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 5 Dienstag, 15. April 2008 5:17 17 Mounting and dismounting Mounting Step 1 dia 20.1 to 20.2 mm 2.5 to 2.9 mm Insert the snap holder into the mounting hole from the front Verify the correct position (a clicking sound can be heard) Step 2 Insert the sensor into the snap holder from the back Verify the correct position (a clicking sound can be heard) Dismounting Step 1 Apply soft pressure to the sensor lens in the indicated areas (e.g. with two thumbs) Remove the sensor Step 2 Press down both snap-fits and push the snap holder forward. E3FZ/E3FR Remove the snap holder 5 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 6 Dienstag, 15. April 2008 5:17 17 Specifications Item Through-beam Retroreflective Diffuse reflective E3FZ-T / E3FR-T E3FZ-R / E3FR-R E3FZ-D / E3FR-D Sensing distance 15 m 4 m [100 mm] 1 m (white paper 300x300 mm) Spot diameter – Standard sensing object Opaque: 12 mm dia .min Opaque: 75 mm dia. min – Differential travel – Black/white error – Directional angle Emitter and Reciever: 3° to 15° Sensor: 3° to 10°, Reflector: 30° – Light source (wave length) Infrared LED (870 nm) Red LED (660 nm) Power supply voltage 10 to 30 VDC, including 10% ripple(p-p) Current consumption 45mA max. (Emitter: 25mA max., Receiver; 20 mA max. ) Control output Load power supply voltage; 30 VDC max., Load current; 100 mA max.(Residual voltage; 2 V max.), Light-on/Dark-on selectable by wire, E3F@-6@: NPN open-collector output E3F@-8@: PNP open-collector output Protective circuits Power supply reverse polarity protection, output short-circuit protection, and reversed output polarity protection 20% max. of sensing distance max. Infrared LED (860 nm) 25 mA max. Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention and reversed output polarity protection Response time Operate and reset; 1 ms max. Sensitivity adjustment – Ambient illumination (receiver side) Incandescent lamp; 3000 lx max., Sunlight 10000 lx max. One-turn adjuster Ambient temperature Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation) Ambient humidity Operating; 35 to 85% RH, Storage; 35 to 95% RH (with no condensation) Insulation resistance 20MΩ min. at 500 VDC Dielectric resistance 1000 VAC at 50/60 Hz for 1 min Vibration resistance Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions Destruction; 500 m/s2, 3 times, each in X, Y and Z directions Shock resistance Degree of protection *1 IEC 60529 IP67, IP69K after DIN 40050-9 Connection method Pre-wired cable (standard length 2 m), Standard M12 connector Indicator Operation indicator: yellow, stability indicator: green (Emitter has only power supply indicator; green) Weight (packed state) Material Accessories *1. 6 Pre-wired approx. 120 g approx. 60 g Standard connector approx. 40 g approx. 20 g Case ABS Cover lens Plate window PMMA Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only). The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water at 80°C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from high pressure water in appearance and functionality. Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 7 Dienstag, 15. April 2008 5:17 17 Specification Item Background suppression (BGS) E3FZ-LS@1H / E3FR-LS@1H E3FZ-LS@6H / E3FR-LS@6H E3FZ-LS@4H / E3FR-LS@4H E3FZ-LS@9H / E3FR-LS@9H Sensing distance 10 to 100 mm (White paper 100x100 mm) 10 to 200 mm (White paper 100x100 mm) Spot diameter 4 mm dia. at sensing distance of 100 mm 18 mm dia. at sensing distance of 200 mm Standard sensing object – Differential travel 3% of sensing distance max. 20% of sensing distance max. Black/white error 5% of sensing distance max. 20% of sensing distance max. Directional angle – Light source (wave length) Red LED (650 nm) Power supply voltage 10 to 30 VDC, including 10% ripple(p-p) Red LED (660 nm) Current consumption 25 mA max. Control output Load power supply voltage; 30 VDC max., Load current; 100 mA max. (Residual voltage; 2 V max.), Light-on/Dark-on selectable by wire, E3F@-LS6: NPN open-collector output E3F@-LS8: PNP open-collector output Protective circuits Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention and reversed output polarity protection Response time Operate and reset; 1 ms max. Sensitivity adjustment – Ambient illumination (receiver side) Incandescent lamp; 3000 lx max., Sunlight 10000 lx max. Ambient temperature Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation) Ambient humidity Operating; 35 to 85%RH, Storage; 35 to 95%RH (with no condensation) Insulation resistance 20MΩ min. at 500 VDC Dielectric resistance 1000 VAC at 50/60 Hz for 1 min Vibration resistance Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions Shock resistance Destruction; 500m/s2, 3 times, each in X, Y and Z directions Degree of protection *1 IEC 60529 IP67, IP69K after DIN 40050-9 Connection method Pre-wired cable (standard length 2m), Standard M12 connector Indicator Operation indicator: yellow, stability indicator: green Weight (packed state) Pre-wired approx.60g Standard connector approx.20g Material Case ABS Cover-lens Plate-window PMMA Accessories *1. Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only). The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water at 80ºC is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from high pressure water in appearance and functionality. E3FZ/E3FR 7 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 8 Dienstag, 15. April 2008 5:17 17 Engineering Data (typical) Parallel Operating Range Through-beam Models Retroreflective Models E3F@-R@1H(R@6H) Distance Y (mm) Distance Y (mm) E3F@-T@1H(T@6H) 1500 1000 500 150 100 E39-R1 50 Y Y 0 E39-R1S 0 X X -500 -50 -1000 -100 -1500 0 5 10 15 20 25 30 35 -150 0 40 1 2 3 4 Distance X (m) 5 6 Distance X (m) Operating Range Sensing object: 300 x 300 white paper 100 Y 80 X 60 40 4 E3F@-LS@4H(LS@9H), left to right Distance Y (mm) E3F@-LS@1H(LS@6H), left to right 140 120 Distance Y (mm) BGS Models E3F@-D@2(D@7) Distance Y (mm) Diffuse reflective Models Sensing object: 100 x 100 white paper 3 2 1 8 Sensing object: 100 x 100 white paper 6 4 Y 2 20 X Y 0 0 0 -20 X -40 -1 -2 -2 -4 -3 -6 -60 -80 -100 -120 -140 0 0.2 0.4 0.6 0.8 1 1.2 1.4 -4 0 1.6 1.8 20 40 60 80 -8 100 0 Distance X (mm) Distance X (m) 50 100 150 200 250 Distance X (mm) Excess Gain vs. Distance Retroreflective Models Diffuse reflective Models 100 50 30 10 5 3 Excess gain ratio (multiple) E3F@-D@2(D@7) E3F@-R@1H(R@6H) Excess gain ratio (multiple) Excess gain ratio (multiple) Through-beam Models E3F@-T@1H(T@6H) 100 100 50 30 10 5 E39-R1S 3 E39-R1 30 10 5 3 Operating 1 level Operating 1 level 0.5 Operating 1 level 0.5 0.5 0.3 0.3 0.3 0.1 0 8 5 10 15 20 25 30 35 40 45 50 Distance (m) Sensing object: 300 x 300 white paper 50 0.1 0.1 0 1 2 3 4 5 6 Distance (m) 0 0.5 1 1.5 2 2.5 Distance (m) Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 9 Dienstag, 15. April 2008 5:17 17 Sensing Object Size vs. Distance Spot Diameter vs. Distance E3F@-D@2(D@7) E3F@-LS@1H(LS@6H) 1.6 1.4 1.2 E3F@-LS@4H(LS@9H) 12 Spot diameter (mm) 1.8 Spot diameter (mm) BGS Models Distance (m) Diffuse reflective Models 10 8 20 18 16 14 12 1.0 6 10 0.8 8 4 0.6 6 0.4 d Sensing object: White paper 4 2 0.2 2 d 0.0 0 100 200 0 0 300 400 500 600 Length d of sensing object (mm) 20 40 60 Sensing Distance vs. Sensing Object Material 50 100 150 200 250 Distance (mm) Inclination Characteristics (Vertical) BGS Models BGS Models E3F@-LS@4H(LS@9H) Sensing distance (mm) 120 100 80 E3F@-LS@1H(LS@6H) 250 Sensing distance variation (%) E3F@-LS@1H(LS@6H) Sensing distance (mm) 0 0 80 100 Distance (mm) 200 150 60 100 10 Upwards and Downwards Inclination angle 8 6 Sensing object 4 Center line +θ −θ 2 0 -2 40 -4 20 50 -6 0 -10 -80 -8 0 White Veneer Card- Black Black SUS paper board paper rubber White Veneer Card- Black Black SUS paper board paper rubber Mirror surface Mirror surface -60 -40 -20 0 20 40 60 80 Inclination angle (°) Material Material Inclination Characteristics (Horizontal) BGS Models E3F@-LS@4H(LS@9H) (Left and Right) Inclination angle 40 30 Sensing object 20 Center line +θ −θ 10 0 50 E3F@-LS@4H(LS@9H) (Left and Right) Inclination angle 40 30 Sensing object 20 Center line +θ −θ 10 0 Sensing distance variation (%) 50 Sensing distance variation (%) Sensing distance variation (%) E3F@-LS@1H(LS@6H) 50 30 20 20 20 30 30 30 40 40 40 50 -80 50 -80 E3FZ/E3FR 0 20 40 60 80 Inclination angle (°) -60 -40 -20 0 20 40 60 80 Inclination angle (°) +θ +θ 0 10 -20 Center line 10 10 -40 Sensing object 20 10 -60 Upwards and Downwards Inclination angle 40 50 -80 -60 -40 -20 0 20 40 60 80 Inclination angle (°) 9 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 10 Dienstag, 15. April 2008 5:17 17 Output Circuit Diagram PNP Output Model Operation Timing charts mode Mode selector switch E3F@-T8 E3F@-R8 E3F@-D8 Light ON Connect the pink wire (Pin(2)) to the brown (Pin(1)) or open the pink wire (Pin(2). Light Incident Light Interrupted Operation indicator ON (yellow) OFF Output transistor Load (e.g., relay) Dark ON ON OFF Operate Reset (Between brown and black wires) Load (e.g., relay) ON OFF Operate Reset Through-beam Receivers, retroreflective models, diffuse reflective models Operation indicator (Yellow) Connect the pink wire (Pin(2)) to the blue (Pin(3)). Light Incident Light Interrupted Operation indicator ON (yellow) OFF Output transistor Output circuit Brown Stability indicator (Green) Photoelectric Sensor Main Circuit 10 to 30 VDC 1 ZD Black (Control output) 4 100 mA max. Load (Relay) 3 0V Blue (Between brown and black wires) Through-beam Emitter Power indicator (green) Brown 1 Photoelectric Sensor Main Circuit 10 to 30 VDC Blue 3 E3F@-LS8 Light ON NEAR FAR Operation indicator ON (yellow) OFF Output transistor Load (e.g., relay) ON OFF Operate Reset (Between brown and black wires) Dark ON NEAR FAR Operation indicator ON (yellow) OFF Output transistor Load (e.g., relay) ON OFF Operate Reset Connect the pink wire (Pin(2)) to the brown (Pin(1)) or open the pink wire (Pin(2). Connect the pink wire (Pin(2)) to the blue (Pin(3)). Operation indicator (Yellow) Stability indicator (Green) Photoelectric Sensor Main Circuit 1 Brown 10 to 30 VDC Light-ON ZD Black 100 mA max. (Control output) 4 Blue Load (Relay) 3 2 0V Pink Dark-ON (Between brown and black wires) 10 Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 11 Dienstag, 15. April 2008 5:17 17 NPN Output Model Operation Timing charts mode Mode selector switch E3F@-T6 E3F@-R6 E3F@-D6 Light ON Connect the pink wire (2) to the blue wire (3) or leave open. Light Incident Light Interrupted Operation indicator ON (yellow) OFF ON Output transistor Load (e.g., relay) Dark ON OFF Operate Reset Output circuit Through-beam receivers, retroreflective models, diffuse reflective models (Between brown and black wires) Operation indicator (Yellow) Connect the pink wire (2) to the brown wire (1). Light Incident Light Interrupted Operation indicator ON (yellow) OFF ON Output transistor Brown Stability indicator (Green) 10 to 30 VDC 1 (Control output) Photoelectric Sensor Main Circuit 100 mA max. 4 Load (Relay) Black ZD Blue 3 0V OFF Load (e.g., relay) Operate Reset (Between brown and black wires) Through-beam Emitter Brown Power indicator (green) 1 Photoelectric Sensor Main Circuit 10 to 30 VDC Blue 3 E3F@-LS6 Light ON NEAR FAR Operation indicator ON (yellow) OFF Output transistor Load (e.g., relay) ON OFF Operate Reset Connect the pink wire (2) to the blue wire (3) or leave open. (Between brown and black wires) Dark ON NEAR FAR Operation indicator ON (yellow) OFF Output transistor Load (e.g., relay) ON OFF Operation indicator (Yellow) Stability indicator (Green) 1 Light-ON Photoelectric Sensor Main Circuit Connect the pink wire (2) to the brown wire (1). 10 to 30 VDC Brown 4 Load (Relay) Black 100 mA max. (Control output) ZD 3 2 Blue 0V Pink Dark-ON Operate Reset (Between brown and black wires) Connector Pin Arrangement Connectors (Sensor I/O connectors) M12 Pre-wired Connector (-M1J) M12 4-wire Connectors M12 Connector Pin Arrangement Pin No. 2 1 2 1 4 3 4 3 Wire color Brown White Blue Black 1 2 3 4 XS2F-D421-D80-A XS2F-D421-G80-A Classification DC E3FZ/E3FR Wire color Brown White Blue Black Connector pin No. A B C D XS2F-D422-D80-A XS2F-D422-G80-A Application Power supply (+V) Operation selection Power supply (0 V) Output 11 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 12 Dienstag, 15. April 2008 5:17 17 Dimensions Note: All units are in millimeters unless otherwise stated. E3FZ-Series E3FZ-T@ Emitter Pre-wired models Connector models Power indicator (green) Power indicator (green) M18x1 6g M18x1 6g 4 dia Optical Axis 15 16.25 5.20 E3FZ-T@ Receiver 16.25 M12x1 6g 9.30 30.25 Stability indicator (green) 30.35 Stability indicator (green) M18x1 6g Operation indicator (yellow) M18x1 6g Operation indicator (yellow) 4 dia Optical Axis 15 16.25 5.20 E3FZ-R@ E3FZ-LS@ 16.25 M12x1 6g 9.30 30.25 Stability indicator (green) 30.35 Stability indicator (green) M18x1 6g Emitter Operation indicator (yellow) M18x1 6g Operation indicator (yellow) Receiver 4 dia 3.50 Optical Axis 15 16.25 5.20 E3FZ-D@ 16.25 M12x1 6g 9.30 30.25 Stability indicator (green) 30.35 Stability indicator (green) M18x1 6g Emitter M18x1 6g Operation indicator (yellow) Operation indicator (yellow) Sensitivity adjuster Sensitivity adjuster Receiver 4 dia 3.50 Optical Axis 15 16.25 16.25 M12x1 6g 22.55 5.20 12 30.25 9.30 30.35 Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 13 Dienstag, 15. April 2008 5:17 17 E3FR Series Pre-wired models Connector models E3FR-T@1H 2M Power indicator (green) 30.35 25.75 18.25 16.25 R8. 10.75 R8. 3 10.75 Optical axis 40.40 Emitter 40.40 15 Optical axis 15 3 25.75 18.25 Stability indicator (green) M18x1 6g 30.35 M18x1 6g Operation indicator (yellow) M12x1 6g 4 dia 9.30 5.20 16.25 Receiver E3FR-R@1H 2M E3FR-LS@1H 2M R8. 3 25.75 18.25 Receiver Optical axis 10.75 R8. 3 15 15 30.35 10.75 Optical axis 3.50 3.50 Stability indicator (green) 25.75 18.25 Receiver Operation indicator (yellow) Emitter 40.40 40.40 Emitter 16.25 M18x1 6g M18x1 6g 4 dia 9.30 5.20 M12x1 6g E3FR-D@2 2M 3 R8. 3 15 Emitter Emitter 40.40 22.55 10.75 Optical axis 3.50 15 30.35 Operation indicator (yellow) 10.75 3.50 Stability indicator (green) 25.75 18.25 Receiver 16.25 M18x1 6g 40.40 R8. 25.75 18.25 Receiver Optical axis M18x1 6g Sensitivity adjuster E3FZ/E3FR 9.30 4 dia 5.20 M12x1 6g 13 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 14 Dienstag, 15. April 2008 5:17 17 Accessories E39-R1S Two, 3.5 dia. 40.3 34 7.5 7 59.9 52 Material: ABS base, acrylic surface 8 2.7 1.6 E38-R49 34.5 7.4 32.8 12.6 6.5 Material: ABS base, acrylic surface ~ 2-3 E39-EL8 14 16 32 15° 15° 38 4.3 20 20.15 2.5 Material: stainless steel 6 30 42 E39-EL9 (can be attached to dia 12 mm mounting rod) Material: stainless steel Ø 25 Snap mount tool 1.5 15.5 Material: ABS 14 Standard Photoelectric Sensors E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 15 Dienstag, 15. April 2008 5:17 17 Safety precautions Precautions for Correct Use ! Warning This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. ! Caution Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explostion may result. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.39 to 0.49 N·m for M12 connectors. Load Do not use a load that exceeds the rated load. Rotation Torque for Sensitivity Adjustment Adjust with a torque of 0.05 N·m or less. Environements with Cleaners and Disinfectants (e.g., Food Processing Lines) Do not use the Sensor in environments subject to cleaners and disifectants. They may reduce the degree of protection. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Cleaning Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Do not use the Sensor in any atmosphere or environment that exceeds the ratings. Do not install the Sensor in the following locations. (1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock Connecting and Mounting (1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6) Mount the Sensor either using the bracket (sold separately) or on a flat surface. (7) Be sure to turn OFF the power supply before inserting or removing the connector. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Power Supply Reset Time The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset. The load short-circuit protection will operate when the current flow reaches 1.8 times the rated load current. When using a capacitive load, use an inrush current of 1.8 times the rated load current or higher. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor. E3FZ/E3FR 15 E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 16 Dienstag, 15. April 2008 5:17 17 WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the DIMENSIONS AND WEIGHTS customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Cat. No. E55E-EN-01 Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu 16 Standard Photoelectric Sensors
E3FZ-LS66H 价格&库存

很抱歉,暂时无法提供与“E3FZ-LS66H”相匹配的价格&库存,您可以联系我们找货

免费人工找货