R
General-Purpose Photoelectric Sensor
E3JU
Compact Limit Switch Style with
Universal Power Supply
H FET output allows for solid state
switching of AC or DC
H Universal AC/DC power supply
H Choose cable or connector types
H Sensitivity adjustment standard on all
models
H Wide selection of timing options
H UL/CE/CSA certified
H NEMA 4X, IP67 rated
Ordering Information
J SENSORS
Method of detection
Sensing distance
Through-beam
Polarized
retroreflective
Diffuse reflective
25 m (82 ft)
5 m (16.4 ft)
1 m (3.3 ft)
2 m (6.6 ft)
Output
Connection
Timer
Part number
Relayy
300-V cable
No
E3JU-25M4-3
E3JU-R5M4-3
E3JU-D1M4-3
E3JU-D2M4-3
E3JU-25M4-6
E3JU-R5M4-6
E3JU-D1M4-6
E3JU-D2M4-6
E3JU-25M4T-3
E3JU-R5M4T-3
E3JU-D1M4T-3
E3JU-D2M4T-3
E3JU-25M4T-6
E3JU-R5M4T-6
E3JU-D1M4T-6
E3JU-D2M4T-6
E3JU-25P4-3
E3JU-R5P4-3
E3JU-D1P4-3
E3JU-D2P4-3
E3JU-25P4-6
E3JU-R5P4-6
E3JU-D1P4-6
E3JU-D2P4-6
E3JU-25P4T-3
E3JU-R5P4T-3
E3JU-D1P4T-3
E3JU-D2P4T-3
E3JU-25P4T-6
E3JU-R5P4T-6
E3JU-D1P4T-6
E3JU-D2P4T-6
600-V cable
300-V cable
Yes
600-V cable
FET
300-V cable
No
600-V cable
300-V cable
Yes
600-V cable
Relayy
FET
MiniChangeR
C a ge
Connector
No
E3JU-25M4-MN1
E3JU-R5M4-MN1
E3JU-D1M4-MN1
E3JU-D2M4-MN1
Yes
E3JU-25M4T-MN1
E3JU-R5M4T-MN1
E3JU-D1M4T-MN1
E3JU-D2M4T-MN1
MiniChangeR
C a ge
Connector
No
E3JU-25P4-MN1
E3JU-R5P4-MN1
E3JU-D1P4-MN1
E3JU-D2P4-MN1
Yes
E3JU-25P4T-MN1
E3JU-R5P4T-MN1
E3JU-D1P4T-MN1
E3JU-D2P4T-MN1
J ACCESSORIES (ORDER SEPARATELY, NOT INCLUDED WITH SENSOR)
Description
Part number
Mounting bracket
E39-LU1
Mounting bracket for E39-R1 reflector
E39-L7
Large corner cube reflector
81 x 60 x 7 mm (3.19 x 2.36 x 0.28 inch)
E39-R2
Small corner cube reflectors
38 x 22 x 11 mm (1.50 x 0.87 x 0.43 inch)
E39-R3
23 x 14 x 5 mm (0.91 x 0.55 x 0.19 inch)
E39-R4
35 x 10 x 0.7 mm (1.38 x 0.39 x 0.03 inch)
E39-RSA
40 x 35 x 0.7 mm (1.57 x 1.38 x 0.03 inch)
E39-RSB
Adhesive backed reflectors
E3JU
E3JU
J REPLACEMENT PARTS
Description
Part number
Reflector (supplied with retroreflective sensors)
E39-R1
Specifications
Part number
E3JU-25j4j-j
E3JU-R5j4j-j
E3JU-D1j4j-j
Method of detection
Through-beam type
Polarized retroreflective
Diffuse reflective
Supply voltage
24 to 240 VAC !10%, 50/60 Hz
12 to 240 VDC, 10% max. peak-to-peak ripple
Power consumption
Emitter: 2 W max.
Receiver: 3.5 W max.
3.5 W max.
4 W max.
Sensing distance
25 m (82 ft)
5 m (16.4 ft) with E39-R1
reflector (supplied)
5.5 m (18.0 ft) with E39-R2
3.3 m (10.8 ft) with E39-R3
1.5 m (4.9 ft) with E39-R4
0.8 m (2.6 ft) with E39-RSB
0.5 m (1.6 ft) with E39-RSA
1 m (3.3 ft) Kodak
gray card white side
90% reflective
Light source
Infrared LED
(950 nm)
Polarized red LED
(660 nm)
Infrared LED (950 nm)
Detectable object type
Opaque, 16 mm
(0.63 in) minimum
Opaque, 56 mm (2.2 in)
minimum with E39-R1
Opaque and translucent materials
Operation mode
Light-ON/Dark-ON, switch selectable
Sensitivity adjustment
Adjustable
Mutual interference protection
Not provided
Control
output
Type
SPDT relay
Max. load
3 A, 250 VAC; 30 VDC rated (p.f.=1)
Min. load
10 mA, 5 VDC minimum
Response
time
Models without timer and timer models set to No Timer: 12 ms ON (6 ms typ.), 12 ms OFF (5 ms typ.)
Models with timer: 0.1 to 10 sec (adjustable)
Type
Power MOSFET relay
Max. load
400 mA AC/DC (600 mA up to 40" C) 240 VAC max., 100 VDC max.
Response
time
Models without timer and timer models set to No Timer: 8 ms ON, 12 ms OFF max.
Models with timer: 0.1 to 10 sec (adjustable)
Type
ON-delay, OFF-delay, ON/OFF delay, one-shot, delayed one-shot; switch selectable
Range
0.1 to 10 seconds
Contact
Solid
state
Timer functions
Not provided
Indicators
Light incident (red LED); output operation (yellow LED); stability (green LED)
Lens
Plastic: PMMA
Case
Plastic: Case-ABS/Polycarbonate blend, Cover-Polycarbonate
Mounting
Connections
Two M5 front-mounting through holes. M30 externally threaded base and 1/2-14 NPSM internal
threads for cable type: conduit torque not to exceed 100 inch-lbs.
Prewired
(--6) 600 V rated, AWG 20: 2-wire, 4-wire cables; AWG 21: 5-wire cables; (--3) 300 V rated; AWG 22:
4-wire, 5-wire cables
Connector
MiniChangeR style connector: 2, 4, and 5 pins
(This table continues on the next page.)
2
2 m (6.6 ft) Kodak
gray card white side
90% reflective
Provided
Circuit protection
Materials
E3JU-D2j4j-j
E3JU
E3JU
Specifications Table -- continued from previous page
Part number
E3JU-25j4j-j
E3JU-R5j4j-j
E3JU-D1j4j-j
Method of detection
Through-beam type
Polarized
retroreflective
Diffuse reflective
Emitter: (--6): 260 g (9.1 oz);
(--3): 180 g (6.3 oz)
(--6): 300 g (10.5 oz); (--3): 220 g (7.7 oz)
(--6): 315 g (11.03 oz);
((--3):
3): 235 g (8.23 oz)
((--MN1):
) 130 g ((4.55 oz))
((--MN1):
) 145 g ((5.08 oz))
Weight
Prewired
E3JU-D2j4j-j
Receiver (--6): 300 g (10.5 oz);
(--3): 220 g (7.7 oz)
Connector
Emitter: 115 g ( 4.03 oz)
Receiver: 130 g (4.55 oz)
Enclosure
ratings
NEMA
NEMA 1, 2, 3, 4X, 5, 12
IEC 144
IP67
Approvals
pp
UL
Listing E41515
CSA
Certification LR45951
Ambient
temperature
CE
IEC947-5-2
Operating
-25"C to 55"C (-13"F to 131"F)
Storage
-40"C to 70"C (-40"F to 158"F)
Engineering Data
J EXCESS GAIN
E3JU-25j4j-j
E3JU-R5j4j-j
E3JU-D1j4j-j
Excess gain ratio
Excess gain ratio
Excess gain ratio
100
10
1
Sensing distance (m)
Sensing distance (m)
Sensing distance (m)
Excess gain ratio
E3JU-D2j4j-j
Sensing distance (m)
3
E3JU
E3JU
J OPERATING RANGE
Operating Range (Typical)
E3JU-25j4j-j
E3JU-R5j4j-j
1.5
18
1.0
12
Operating range (m)
24
0.5
-0.0
-0.5
-1.0
6
0
-6
-12
-18
-15
-24
-20
0
5
10
15
20
Sensing distance (m)
Operating range (m)
E3JU-D2j4j-j
Sensing distance (m)
4
E3JU-D1j4j-j
2.0
Operating range (m)
Parallel operating range (m)
Parallel Operating
Range (Typical)
25
30
0.0
Sensing distance (m)
0.2
0.4
0.6
0.8
1.0
Sensing distance (m)
1.2
1.4
E3JU
E3JU
Nomenclature
J SENSOR WITHOUT TIMER
E3JU-jjj4-j
J SENSOR WITH TIMER
E3JU-jjj4T-j
5
E3JU
E3JU
Operation
J OUTPUT CIRCUIT DIAGRAMS
Solid State Relay Output Types
E3JU-jjPjj-j
Relay Output Types
E3JU-jjMjj-j
Main
circuit
Power
supply
24 to 240 VAC
12 to 240 VDC
(50/60 Hz AC)
Either polarity
Main
circuit
Optically
isolated
NC
COM
24 to 240 VAC
12 to 240 VDC
(50/60 Hz AC)
Either polarity
Power
supply
0.1 to 400 mA
Load*
Power
supply
Relay output
250 VAC, 3 A rated
5 VDC, 10 mA min.
Line voltage
5 to 240 VAC
5 to 100 VDC
Either polarity
Load*
NO
* Load can be hooked up on either side of the power supply.
J CONNECTIONS
Prewired types
Connector Types
Through-beam Emitter Types
E3JU-25L-3
E3JU-25L-6
Through-beam Emitter Type
E3JU-25L-MN1
2
Brown
Power
1
24 to 240 VAC
12 to 240 VDC
24 to 240 VAC
Power 12 to 240 VDC
Blue
Relay Output Types
E3JU-jjMjj-3
E3JU-jjMjj-6
Relay Output Types
E3JU-jjMjj-MN1
3
Brown
4
24 to 240 VAC
Power 12 to 240 VDC
Blue
COM
NO
NC
COM
1
5
NO
NC
Gray
Black
White
Solid State Relay Output Types
E3JU-jjPjj-3
E3JU-jjPjj-6
Solid State Relay Output Types
E3JU-jjPjj-MN1
Brown
Power
3
24 to 240 VAC
12 to 240 VDC
Load
White
Black Load*
4
2
1
Load*
Blue
6
Power
24 to 240 VAC
12 to 240 VDC
2
Power
Power
* Load can be hooked up on either side
of the power supply.
Power 24 to 240 VAC
12 to 240 VDC
Load
E3JU
E3JU
J TIMING CHART
7
E3JU
E3JU
J SENSITIVITY ADJUSTMENT (DIFFUSE REFLECTIVE SENSORS)
Steps
Step 1
Step 2
Step 3
Function
Determine position A
Determine position B
Adjust to optimum setting
Sensing
condition
Photoelectric sensor
Photoelectric sensor
Target
Target
Background
Sensitivity
adjuster
Procedure
8
Target
Background
A
B
A
Min
Indicators
Photoelectric sensor
Max
ON
LIGHT Incident
Indicator (red)
Place target at the desired sensing
distance. Set sensitivity adjuster to the
minimum scale position, and gradually
increase sensitivity by turning the
sensitivity adjuster clockwise until the
Light Incident indicator (red LED)
turns ON. Position A designates the
point at which the LED has turned ON.
Min
Max
OFF
LIGHT Incident
Indicator (red)
Remove the target. Starting from the
maximum scale position, gradually
decrease sensitivity by turning the
sensitivity adjuster counterclockwise
until the Light Incident indicator (red
LED) turns OFF. Position B
designates the point at which the LED
has turned OFF.
Background
B
Min
Max
OFF
LIGHT Incident
Indicator (red)
Set the sensitivity indicator to the
position between Positions A and B (in
some cases, Positions A and B are
opposite of the above example). To
insure stable sensor operation, the
green stability indicator should be fully
“on” in both the sensing and
non-sensing conditions.
E3JU
E3JU
Dimensions
Unit: mm (inch)
J SENSORS
E3JU-D2jjj-j
E3JU-[R5, 25, D1]jjj-j
9
E3JU
E3JU
J CORNER CUBE REFLECTORS
E39-R1 Reflector
(Included with E3JU-Rjjj-j)
Two, 3.5 (0.14) dia.
E39-L7 R1 Reflector Adapter
for E39-R1 Reflector
(Order Separately)
40.3 (1.59)
34 (1.34)
7 (0.28)
7.5 (0.30)
39.3 (1.56)
34 (1.34)
3.2 (0.13)
12 (0.47)
Nut (M5)
59
(2.32)
59.9
(2.36)
52
(2.05)
52
(2.05)
62.1 (2.44)
M5
Spring
washer
(M5)
Two M3
1.6 (0.06)
8 (0.31)
2.7 (0.11)
J MOUNTING BRACKET
E39-LU1 (Order Separately)
90"!0.5"
61.0 (2.4)
3.0 (0.12)
53.3 (2.1)
35.6 (1.4)
7.1 (0.28)
35.6
(1.4)
rad.
15.2 (0.6)
61.0 (2.4)
35.6 (1.4)
30.7
(1.21) dia.
30.7
(1.21) dia.
71.1 (2.8)
50.8
(2.00) dia.
90"
10
50.8 (2.0)
7.1
(0.28)
E3JU
E3JU
MiniChangeR Connector Cables
J BRAD HARRISON MINICHANGER CONNECTOR CABLES
Connector type
Applicable sensors
Length
Straight
Right angle
5-pole
p
female connectors
E3JU-jjM4j-MN1
3JU jj j
6 foot
41307
41307-90
12 foot
41308
41308-90
20 foot
41322
41322-90
6 foot
41108
41108-90
12 foot
41109
41109-90
20 foot
41177
41177-90
6 foot
40711
40711-90
12 foot
40712
40712-90
20 foot
40748
40748-90
4-pole
p
female connectors
2-pole
p
female connectors
E3JU-jjP4j-MN1
3JU jj j
E3JU-25jj-MN1
3JU 5jj
emitter
e
e
Note: The above part numbers represent Brad Harrison (Daniel Woodhead) part numbers not Omron part numbers. Please contact your
local Omron distributor for future availability by Omron and other equivalent Connector Cables.
Precautions
!
WARNING
These photoelectric sensors should not be used in personal
safety applications. Using the sensor as a safety device may
cause an unsafe condition that could lead to serious injury or
death.
! CAUTION
Cover Screw Torque:
The torque of the cover screw must not exceed 3.5 kgScm
(3 inSlb). Over-torquing twill cause the plastic parts to crack.
J HIGH-VOLTAGE LINES
Do not place sensor power supply or signal lines within the same
conduit as high-voltage power lines.
J VOLTAGE RATINGS
Do not exceed rated supply voltage, ripple percent (for DC
models), or load current limits.
J POWER SUPPLY
If a switching power supply is used, or when using with an
inverter or servomotor, ground the FG (frame ground) and
G (ground) terminals on the power supply for proper operation to
avoid damaging the sensor.
J WATER EXPOSURE
Do not use the sensor where it may be immersed, is outdoors, or
exposed to rain.
J PROPER MOUNTING SCREWS
Use M5 screws and washers to mount sensor and bracket.
J MECHANICAL SHOCK
Avoid mechanical shock during installation which may damage
the housing.
J CONNECTOR
J AMBIENT LIGHTING
#
Do not install sensor in direct sunlight, or other sources of strong
ambient light.
#
J ENVIRONMENTAL CONDITIONS
Do NOT install sensor in areas that have any of these conditions:
#
#
#
High humidity, or where condensation would result.
Corrosive gas.
High vibration or shock.
C:/CEDSAX4
#
#
When connecting or disconnecting the connector, hold the
connector cover to avoid tension on housing.
Tighten connector only by hand. Do not use tools, which may
damage the connector.
Always disconnect power before connecting or disconnecting
the connector.
Be sure that the connector is tightened securely. If this is not
done, the sensor enclosure rating may be reduced, or the
connector may loosen and affect the enclosure rating.
11
E3JU
E3JU
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC
OMRON ON--LINE
OMRON CANADA, INC.
1-800-55-OMRON
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
416-286-6465
One East Commerce Drive
Schaumburg, IL 60173
Cat. No. E00SAD5
04/02
Specifications subject to change without notice.
885 Milner Avenue