Smart Fiber Amplifier Units
E3NX-FA
CSM_E3NX-FA_DS_E_16_2
A Smart Fiber Amplifier Unit with
Ultra-stable Detection and
Ultra-easy Setup
• Improved basic performance with 1.5 times the sensing distance and
approx. 1/10th the minimum sensing object.*
• Ultra-easy setup with Smart Tuning with a light intensity adjustment
range expanded 20 times to 40,000:1. Optimum stable detection
achieved with light intensity adjustment even for saturated incident light.
• White on black display characters for high visibility.
• Solution Viewer that shows the passing time and difference in incident
levels and Change Finder that allows you to see display values even
for fast workpieces.
* Compared to the E3X-HD.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to the Safety Precautions on
page 17.
Ordering Information
Fiber Amplifier Units (Dimensions ➜ pages 19 and 20)
Type
Connecting method
Pre-wired (2 m)
Appearance
NPN output
PNP output
E3NX-FA11 2M
E3NX-FA41 2M
E3NX-FA11-5 2M
*1
---
1 output
Standard models
Advanced models
Model
Inputs/outputs
Wire-saving Connector
1 output
E3NX-FA6
E3NX-FA8
Pre-wired (2 m)
2 outputs + 1 input
E3NX-FA21 2M
E3NX-FA51 2M
1 output + 1 input
E3NX-FA7
E3NX-FA9
2 outputs
E3NX-FA7TW
E3NX-FA9TW
1 output + 1 input
E3NX-FA24
E3NX-FA54
2 outputs
---
E3NX-FA54TW
Wire-saving Connector
M8 Connector
*1. This type can prevent mutual interference for two units in the SHS2 mode.
1
E3NX-FA
Type
Connecting method
Appearance
Inputs/outputs
Model
NPN output
PNP output
Pre-wired (2 m)
1 output
E3NX-FAH11 2M
E3NX-FAH41 2M
Wire-saving Connector
1 output
E3NX-FAH6
E3NX-FAH8
Pre-wired (2 m)
2 outputs
E3NX-FA11AN 2M
E3NX-FA41AN 2M
Infrared models
Analog output
models
E3NX-FA0
Connector for Sensor
Communications Unit
---
E3NX-FAH0
Model for Sensor
Communications Unit *2
Connector for Sensor
Communications Unit
Pre-wired (2 m)
E3NX-FA10 2M
1 output
E3NX-FA40 2M
*2. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.) (Dimensions ➜ page 21)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. Note: Protective stickers are provided.
Type
Appearance
Cable length No. of conductors
Model
Master Connector
4
E3X-CN21
Slave Connector
2
E3X-CN22
3
E3X-CN11
Applicable Fiber Amplifier Units
E3NX-FA7
E3NX-FA7TW
E3NX-FA9
E3NX-FA9TW
2m
Master Connector
E3NX-FA6
E3NX-FA8
Slave Connector
E3X-CN12
1
Sensor I/O Connectors (Required for models for M8 Connectors.) (Dimensions ➜ page 21)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Size
Cable
Appearance
Straight
M8
Standard cable
L-shaped
Cable type
2m
5m
2m
5m
Model
XS3F-M421-402-A
4-wire
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
2
E3NX-FA
Mounting Bracket (Dimensions ➜ page 22)
A Mounting Bracket is not provided with the Fiber Amplifier Unit.
It must be ordered separately as required.
Appearance
Quantity
Type
E39-L143
1
Sensor Communications
Unit for EtherCAT
E3NW-ECT
Sensor Communications
Unit for CompoNet
E3NW-CRT *1
Sensor Communications
Unit for CC-Link
E3NW-CCL
Distributed Sensor Unit *2
E3NW-DS
A DIN Track is not provided with the Fiber Amplifier Unit. It must
be ordered separately as required.
Type
Model
PFP-100N
Shallow type, total length: 0.5 m
PFP-50N
Deep type, total length: 1 m
PFP-100N2
1
End Plate (Dimensions ➜ page 22)
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit. They
must be ordered separately as required.
Model
PFP-M
Quantity
1
Cover
Attach these Covers to Amplifier Units.
Order a Cover when required, e.g., if you lose the covers.
Appearance
Appearance
Model
Quantity
Shallow type, total length: 1 m
Appearance
Sensor Communications Units
Model
DIN Track (Dimensions ➜ page 22)
Appearance
Related Products
Model
Quantity
E39-G25 FOR E3NX-FA
1
Refer to your OMRON website for details.
*1. E3NX-FAH0 can not be connected.
*2. The Distributed Sensor Unit can be connected to any of the
Sensor Communications Units.
EtherCAT® is a registered trademark and patented
technology, licensed by Beckhoff Automation GmbH,
Germany.
CompoNet is a registered trademark of the ODVA.
CC-Link is a registered trademark of Mitsubishi Electric
Corporation. The trademark is managed by the CC-Link
Partner Association.
3
E3NX-FA
Ratings and Specifications
Standard models/ Advanced models/ Infrared models
Type
NPN output
PNP output
Connecting
Item
method
Outputs
Inputs/
outputs External inputs
Light source (wavelength)
Power supply voltage
Power consumption *2
Standard models
Advanced models
E3NX-FA11 E3NX-FA6 E3NX-FA11-5 *1 E3NX-FA21 E3NX-FA7 E3NX-FA7TW E3NX-FA24
--E3NX-FA41 E3NX-FA8
--E3NX-FA51 E3NX-FA9 E3NX-FA9TW E3NX-FA54 E3NX-FA54TW
Wire-saving
Pre-wired
Pre-wired
Pre-wired Wire-saving Connector
M8 Connector
Connector
1 output
2 outputs
1 output
2 outputs
1 output
2 outputs
--1 input
1 input
--1 input
--Red, 4-element LED (625 nm)
10 to 30 VDC, including 10% ripple (p-p)
At Power supply voltage of 24 VDC
Standard Models:
Normal mode : 840 mW max. (Current consumption at 35 mA max.)
Eco function ON : 650 mW max. (Current consumption at 27 mA max.)
Eco function LO : 750 mW max. (Current consumption at 31 mA max.)
Infrared models
E3NX-FAH11 E3NX-FAH6
E3NX-FAH41 E3NX-FAH8
Wire-saving
Pre-wired
Connector
1 outputs
--Infrared LED (870nm)
Advanced Models or Model for Sensor Communications Unit:
Normal mode : 920 mW max. (Current consumption at 38 mA max.)
Eco function ON : 680 mW max. (Current consumption at 28 mA max.)
Eco function LO : 800 mW max. (Current consumption at 33 mA max.)
Infrared models:
Normal mode : 1080 mW max. (Current consumption at 45 mA max.)
Eco function ON : 920 mW max. (Current consumption at 38 mA max.)
Eco function LO : 1020 mW max. (Current consumption at 42 mA max.)
Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format)
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
Control output
External inputs
Indicators
Protection circuits
Super-highspeed mode
(SHS)
High-speed
Response mode (HS)
time
Standard
mode (Stnd)
Giga-power
mode (GIGA)
OFF current: 0.1 mA max.
--Refer to *3.
--Refer to *3. --7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed.
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green),
and OUT selection indicator (orange, only on models with 2 outputs)
Power supply reverse polarity protection, output short-circuit protection, and output reve rse polarity protection
Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs
Operate or reset: 250 μs
Operate or reset: 1 ms
Operate or reset: 16 ms
Sensitivity adjustment
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or
percentage tuning (-99% to 99%)) or manual adjustment
Maximum connectable Units
Super-highspeed mode
(SHS)
No. of Units
for mutual High-speed
interference mode (HS)
prevention Standard
*4 mode (Stnd)
Giga-power
mode (GIGA)
30
0
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention
function is disabled.
10
10
10
*1. This type can prevent mutual interference for two units in the SHS2 mode.
*2. At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode
: 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC)
Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC)
Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC)
Advanced Models:
Normal mode
: 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC)
Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC)
Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC)
Infrared models:
Normal mode
: 1,260 mW max. (Current consumption: 42 mA max. at 30 VDC, 80 mA max. at 10 VDC)
Eco function ON : 1,050 mW max. (Current consumption: 35 mA max. at 30 VDC, 60 mA max. at 10 VDC)
Eco function LO : 1,140 mW max. (Current consumption: 38 mA max. at 30 VDC, 70 mA max. at 10 VDC)
*3. The following details apply to the input.
Contact input (relay or switch)
Non-contact input (transistor)
NPN
ON: Shorted to 0 V (Sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc − 1.5 V to Vcc (Leakage current: 0.1 mA max.)
PNP
ON: Shorted to Vcc (Sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc − 1.5 V to Vcc (Sinking current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)
Input time *3-1
ON: 9 ms min.
OFF: 20 ms min.
*3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
4
E3NX-FA
Type
Advanced models
Infrared models
NPN output
E3NX-FA11
E3NX-FA6
E3NX-FA11-5 *1
E3NX-FA21
E3NX-FA7
E3NX-FA7TW
E3NX-FA24
PNP output
E3NX-FA41
E3NX-FA8
---
E3NX-FA51
E3NX-FA9
E3NX-FA9TW
E3NX-FA54
Pre-wired
Wire-saving
Connector
Connectin
g method
Item
Standard models
Pre-wired
Pre-wired
Wire-saving Connector
---
E3NX-FAH11
E3NX-FA54TW E3NX-FAH41
M8 Connector
Pre-wired
E3NX-FAH6
E3NX-FAH8
Wire-saving
Connector
Automatic power
Always enabled.
control (APC)
Dynamic power
control (DPC)
Provided
Timer
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting
settings *5
Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode *6
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching
Select from banks 1 to 4.
Power tuning Select from ON, OFF or Execution on power-up.
Select from ON or OFF.
Output 1
Select from normal
detection mode or area
detection mode.
Select from normal detection mode, area detection mode or differential detection mode.
Select from
normal
detection
mode,
alarm
output
mode, error
output
mode or
differential
detection
mode.
Functions
Output 2
External
input
---
---
Select from input OFF,
tuning, power tuning,
emission OFF, zero reset,
or bank switching.
---
Select from
normal
detection
mode,
alarm
output
mode, error
output
mode or
differential
detection
mode.
---
Select from
normal
detection
mode,
alarm
output
mode, error
output
mode or
differential
detection
mode.
---
Select from
input OFF,
tuning,
power
tuning,
emission
OFF, zero
reset, or
bank
switching.
---
---
Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination
(Receiver side)
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature
range *7
Operating:
Groups of 1 or 2 Amplifier Units: −25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage: −30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above
Altitude
2,000 m max.
Installation
environment
Pollution degree 3
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/
Sensor only)
Approx. 115 g/ Approx. 60g/
approx. 75 g
approx. 20g
Case
Materials Cover
Cable
Accessories
Approx. 115 g/ Approx. 115 g/ Approx. 60g/
approx. 75 g
approx. 75 g
approx. 20g
Approx. 65 g/
approx. 25 g
Approx. 115 g/ Approx. 60g/
approx. 75 g
approx. 20g
Polycarbonate (PC)
Polycarbonate (PC)
PVC
Instruction Manual
*5. The bank is not reset by the user reset function or saved by the user save function.
*6. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
*7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
5
E3NX-FA
Analog output models/ Model for Sensor Communications Unit
Type
Model for Sensor Communications Unit
E3NX-FA11AN
E3NX-FA10
PNP output
E3NX-FA41AN
E3NX-FA40
Pre-wired
Connector for Sensor
Communications Unit
Pre-wired
Connecting
method
Item
Inputs/
outputs
Analog output models
NPN output
Outputs
2 outputs
1 outputs
External inputs
---
---
E3NX-FA0
E3NX-FAH0
Connector for Sensor Communications Unit
--- *1
Light source (wavelength)
Red, 4-element LED (625 nm)
Power supply voltage
10 to 30 VDC, including 10%
ripple (p-p)
Power consumption *2
At Power supply voltage of 24 VDC
Normal mode : 960 mW max.
At Power supply voltage of 24 VDC
(Current consumption at 40 mA
Normal mode : 920 mW max.
max.)
(Current consumption at 38 mA max.)
Eco function ON: 770 mW max.
Eco function ON: 680 mW max.
(Current consumption at 32 mA
(Current consumption at 26 mA max.)
max.)
Eco function LO : 800 mW max.
Eco function LO : 870 mW max.
(Current consumption at 33 mA max.)
(Current consumption at 36 mA
max.)
At Power supply voltage of 24 VDC
Normal mode : 1,080 mW max.
(Current consumption at 45 mA
max.)
Eco function ON: 920 mW max.
(Current consumption at 38 mA
max.)
Eco function LO : 1,020 mW max.
(Current consumption at 42 mA
max.)
Control output
Load power supply voltage:
30 VDC max., open-collector output
(depends on the NPN/PNP output format)
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max.,
Groups of 4 to 30 Amplifier Units:20 mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
---
Infrared LED (870nm)
Supplied from the connector through the communication units.
(
)
Analog output (reference value)
Voltage output: 1-5 VDC
(10 kΩ or more connected load),
temperature characteristics:
0.3% F.S. / °C
Indicators
7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed.
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green),
and OUT selection indicator (orange, only on models with 2 outputs)
Protection circuits
Power supply reverse polarity protection,
output short-circuit protection, and output reverse polarity
protection
Super-high-speed mode
(SHS)
Control
High-speed mode (HS)
output
Response Standard mode (Stnd)
time
Giga-power mode
(GIGA)
Sensitivity adjustment
Maximum connectable Units
No. of Units
for mutual
interference
prevention
*3
Operate or reset: 80 μs
---
Power supply reverse polarity protection and output shortcircuit protection
Operate or reset: 32 μs
Operate or reset: 250μs
Operate or reset: 250 μs
Operate or reset: 1 ms
Operate or reset: 1 ms
Operate or reset: 16 ms
Operate or reset: 16 ms
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,
percentage tuning (−99% to 99%)) or manual adjustment
30
16
With E3NW-ECT: 30 units
(When connected to an OMRON NJ-series Controller.)
With E3NW-CRT: 16 units
(Note: E3NX-FAH0 can not be connected.)
With E3NW-CCL: 16 units
Super-high-speed mode
(SHS)
0 (The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.)
High-speed mode (HS)
10
Standard mode (Stnd)
10
Giga-power mode
(GIGA)
10
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. At Power supply voltage of 10 to 30 VDC
Analog output models:
Normal mode
: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
*3. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
6
E3NX-FA
Type
Analog output models
NPN output
E3NX-FA11AN
E3NX-FA10
PNP output
E3NX-FA41AN
E3NX-FA40
Pre-wired
Connector for Sensor
Communications Unit
Pre-wired
Connecting
method
Item
Model for Sensor Communications Unit
E3NX-FA0
E3NX-FAH0
Connector for Sensor Communications Unit
Automatic power control (APC) Always enabled.
Functions
Dynamic power control (DPC)
Provided
Timer
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting settings *4
Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching
Select from banks 1 to 4.
Power tuning
Select from ON or OFF.
Output 1
Select from normal detection mode, area detection mode or differential detection mode (E3NX-FA10/40 only).
Output 2
Select from Analog scaling
or Analog offset.
Hysteresis width
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
---
Select from normal detection mode,
alarm output mode, error output mode
or differential detection mode (E3NX-FA0 only).
Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range *5
Operating:
Groups of 1 or 2 Amplifier
Units: -25 to 55°C,
Groups of 3 to 10 Amplifier
Units: -25 to 50°C,
Groups of 11 to 16 Amplifier
Units: -25 to 45°C,
Groups of 17 to 30 Amplifier
Units: -25 to 40°C
Storage: -30 to 70°C
(with no icing or condensation)
Ambient humidity range
Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above
Altitude
2,000 m max.
Installation environment
Pollution degree 3
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction)
500 m/s2 for 3 times each in X,
Y, and Z directions
150 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only)
Approx. 115 g/approx. 75 g
Approx. 95 g/approx. 45 g
Materials
Case
Polycarbonate (PC)
Cover
Polycarbonate (PC)
Cable
PVC
Accessories
Operating:
Groups of 1 or 2 Amplifier
Units: 0 to 55°C,
Groups of 3 to 10 Amplifier
Units: 0 to 50°C,
Groups of 11 to 16
Amplifier Units: 0 to 45°C
Storage: -30 to 70°C
(with no icing or
condensation)
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C,
Groups of 3 to 10 Amplifier Units: 0 to 50°C,
Groups of 11 to 16 Amplifier Units: 0 to 45°C,
Groups of 17 to 30 Amplifier Units: 0 to 40°C
Storage: −30 to 70°C (with no icing or condensation)
Approx. 65 g/approx. 25 g
Approx. 65 g/approx. 25 g
Instruction Manual
*4. The bank is not reset by the user reset function or saved by the user save function.
*5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
7
E3NX-FA
Sensing Distances
Standard models/ Advanced models/ Analog output models
Threaded Models
Sensing
method
Sensing
direction
Sensing distance (mm)
Size
E32-LT11N 2M
M4
Straight
M3
Right-angle
Giga mode
E32-T11N 2M
Right-angle
Through-beam
Model
M4
M6
M3
M4
M6
Super-highspeed mode
3,000
1,500
1,050
280
4,000 *1
4,000 *1
3,450
920
3,000
1,500
1,050
280
E32-LT11 2M
4,000 *1
4,000 *1
4,000 *1
1,080
E32-LT11R 2M
4,000 *1
4,000 *1
3,450
920
E32-C31N 2M
160
75
69
14
E32-C21N 2M
440
190
130
39
E32-D21N 2M
1,260
520
360
100
E32-C11N 2M
1,170
520
480
100
E32-LD11N 2M
1,260
520
360
100
210
90
60
16
490
220
150
44
E32-C31 2M
E32-C31M 1M
Straight
High-speed
mode
E32-T11R 2M
E32-D21R 2M
Reflective
Standard mode
210
90
60
16
E32-D11R 2M
E32-D211R 2M
1,260
520
360
100
E32-CC200 2M
2,100
900
600
180
E32-LD11 2M
1,290
540
370
110
E32-LD11R 2M
1,260
520
360
100
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Cylindrical Models
Sensing
method
1 dia.
Through-beam
Model
E32-T223R 2M
1.5 dia.
Top-view
3 dia.
Reflective
Sensing distance (mm)
Sensing
direction
Size
Side-view
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
670
370
220
E32-T22B 2M
1,020
600
330
60
90
E32-T12R 2M
3,000
1,500
1,050
280
E32-T14LR 2M
1,120
670
390
100
210
90
60
16
1.5 dia.
E32-D22B 2M
1.5 dia. +
0.5 dia.
E32-D43M 1M
42
18
12
4
E32-D22R 2M
210
90
60
16
Top-view
3 dia.
E32-D221B 2M
E32-D32L 2M
3 dia. +
0.8 dia.
E32-D33 2M
450
210
130
40
1,050
450
300
90
100
45
30
8
Flat Models
Sensing distance (mm)
Sensing
method
Sensing direction
Top-view
E32-T15XR 2M
Through-beam
Side-view
E32-T15YR 2M
Flat-view
E32-T15ZR 2M
Reflective
Model
Top-view
E32-D15XR 2M
Side-view
E32-D15YR 2M
Flat-view
E32-D15ZR 2M
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
3,000
1,500
1,050
280
1,120
670
390
100
1,260
520
360
100
300
150
78
24
8
E3NX-FA
Sleeve Models
Sensing
method
Sensing distance (mm)
Sensing direction
Side-view
Through-beam
Top-view
Model
Super-highspeed mode
250
150
75
20
670
370
220
60
E32-T33 1M
220
130
75
20
E32-T21-S1 2M
760
450
250
68
280
3,000
1,500
1,050
E32-D24R 2M
100
45
30
8
E32-D24-S2 2M
180
79
67
14
E32-D43M 1M
42
18
12
4
E32-D331 2M
21
9
6
2
E32-D33 2M
100
45
30
8
94
40
27
7
210
90
60
16
370
160
100
30
1,260
520
360
100
370
160
100
30
E32-D31-S1 0.5M
Top-view
High-speed
mode
E32-T24E 2M
E32-D32-S1 0.5M
Reflective
Standard mode
E32-T24R 2M
E32-TC200BR 2M
Side-view
Giga mode
E32-DC200F4R 2M
E32-D22-S1 2M
E32-D21-S3 2M
E32-DC200BR 2M
E32-D25-S3 2M
Small-spot, Reflective Models
Type
Variable spot
Parallel light
Integrated lens
Spot diameter
Models
Giga mode
Standard mode
High-speed
mode
0.1 to 0.6 dia.
6 to 15
E32-C42 1M + E39-F3A
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia.
10 to 30
E32-C42 1M + E39-F17
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
4 dia.
0 to 20
E32-C31 2M + E39-F3C
E32-C31N 2M + E39-F3C
5
E32-C42S 1M
Spot diameter of 0.1 mm at 5 mm.
6 dia.
50
E32-L15 2M
Spot diameter of 6 mm at 50 mm.
E32-C41 1M + E39-F3A-5
Spot diameter of 0.1 mm at 7 mm.
0.5 dia.
7
E32-C31N 2M + E39-F3A-5
0.2 dia.
0.5 dia.
3 dia.
E32-C31 2M + E39-F3A-5
E32-C41 1M + E39-F3B
17
E32-C31 2M + E39-F3B
E32-C31N 2M + E39-F3B
50
E32-CC200 2M + E39-F18
E32-C11N 2M + E39-F18
Super-highspeed mode
Spot diameter of 4 mm max. at 0 to 20 mm.
0.1 dia.
0.1 dia.
Small-spot
Sensing distance (mm)
Center
distance (mm)
Spot diameter of 0.5 mm at 7 mm.
Spot diameter of 0.2 mm at 17 mm.
Spot diameter of 0.5 mm at 17 mm.
Spot diameter of 3 mm at 50 mm.
9
E3NX-FA
High-power Beam Models
Type
Through-beam
models with
integrated lens
Sensing distance (mm)
Sensing
direction
Aperture angle
Right-angle
15°
E32-LT11N 2M
4,000 *2
4,000 *2
3,450
920
10°
E32-T17L 10M
20,000 *1
20,000 *1
20,000 *1
8,000
E32-LT11 2M
4,000 *2
4,000 *2
4,000 *2
1,080
E32-LT11R 2M
4,000 *2
4,000 *2
3,450
920
30°
E32-T14 2M
4,000 *2
4,000 *2
4,000 *2
1,800
12°
E32-T11N 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
2,000
6°
E32-T11N 2M + E39-F16
4,000 *2
4,000 *2
4,000 *2
3,600
12°
E32-T11R 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
2,000
6°
E32-T11R 2M + E39-F16
4,000 *2
4,000 *2
4,000 *2
3,600
60°
E32-T11R 2M + E39-F2
2,170
1,200
750
200
12°
E32-T11 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
1,860
4,000 *2
4,000 *2
4,000 *2
4,000 *2
3,450
1,980
1,290
320
Top-view
15°
Side-view
Right-angle
Top-view
Side-view
Top-view
Side-view
Through-beam
models with
lenses
Top-view
Side-view
Top-view
Side-view
Top-view
Side-view
Top-view
Reflective
models with
integrated lens
Models
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
6°
E32-T11 2M + E39-F16
60°
E32-T11 2M + E39-F2
12°
E32-T51R 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
1,500
4,000 *2
4,000 *2
4,000 *2
4,000 *2
2,100
1,080
750
200
6°
E32-T51R 2M + E39-F16
60°
E32-T51R 2M + E39-F2
12°
E32-T81R-S 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
1,000
4,000 *2
4,000 *2
4,000 *2
1,800
1,500
820
540
140
6°
E32-T81R-S 2M + E39-F16
60°
E32-T81R-S 2M + E39-F2
12°
E32-T61-S 2M + E39-F1
4,000 *2
4,000 *2
4,000 *2
1,800
4,000 *2
4,000 *2
4,000 *2
3,100
2,520
1,350
900
240
6°
E32-T61-S 2M + E39-F16
60°
E32-T61-S 2M + E39-F2
12°
E32-T51 2M + E39-F1-33
4,000 *2
4,000 *2
3,450
1,400
6°
E32-T51 2M + E39-F16
4,000 *2
4,000 *2
4,000 *2
4,000 *2
4°
E32-D16 2M
40 to 4,000 *2
40 to 2,100
40 to 1,350
40 to 480
Top-view
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing
method
Sensing distance (mm)
Sensing
direction
Aperture angle
1.5°
Through-beam
3.4°
Side-view
4°
Models
Giga mode
E32-A03 2M
E32-A03-1 2M
E32-A04 2M
Standard mode
4,000 *1
2,670
High-speed
mode
Super-highspeed mode
1,800
500
1,920
1,020
670
200
E32-T24SR 2M
4,000 *1
3,300
2,190
580
E32-T24S 2M
4,000 *1
3,900
2,610
700
E32-T22S 2M
4,000 *1
4,000 *1
3,750
1,000
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing
method
Sensing distance (mm)
Sensing direction
Model
Giga mode
Standard mode
0 to 15
E32-L16-N 2M
Flat-view
Limitedreflective
Side-view
High-speed
mode
Super-highspeed mode
0 to 12
E32-L24S 2M
0 to 4
E32-L25L 2M
5.4 to 9 (center 7.2)
Transparent Object Detection (Retro-reflective Models)
Sensing
method
Sensing distance (mm)
Feature
Size
Models
Film detection
M3
E32-C31 2M +
E39-F3R + E39-RP37
Square
---
E32-R16 5M
Giga mode
Hex-shaped
E32-LR11NP 2M +
E39-RP1
Super-highspeed mode
300
---
150 to 1,500
10 to 370
E32-R21 2M
M6
High-speed
mode
370
Retro-reflective
Threaded
Standard mode
2,020
1,800
10 to 250
1,500
550
10
E3NX-FA
Transparent Object Detection (Limited-reflective Models)
Sensing
method
Feature
Sensing direction
Small size
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
E32-L16-N 2M
0 to 15
0 to 12
E32-A08 2M
10 to 20
---
E32-A12 2M
12 to 30
---
Flat-view
Glass substrate
alignment, 70°C
Standard/long-distance
Super-high-speed mode
0 to 4
E32-L24S 2M
Standard
Limitedreflective
Model
Side-view form
Side-view
E32-L25L 2M
Glass substrate
mapping, 70°C
Top-view
E32-A09 2M
5.4 to 9 (center 7.2)
15 to 38
---
Chemical-resistant, Oil-resistant Models
Sensing
method
Through-beam
Type
Sensing direction
Oil-resistant
Right-angle
Chemical/oil-resistant
Chemical/oil-resistant at
150°C
Semiconductors: Resist
stripping; 85°C
Sensing distance (mm)
High-speed mode
Super-high-speed mode
E32-T11NF 2M
4,000 *1
4,000 *1
4,000 *1
2,200
E32-T12F 2M
4,000 *1
4,000 *1
4,000 *1
1,600
E32-T11F 2M
4,000 *1
4,000 *1
3,900
1,000
Side-view
E32-T14F 2M
2,100
1,200
750
200
Top-view
E32-T51F 2M
4,000 *1
4,000 *1
2,700
700
Top-view
Semiconductors:
Cleaning, developing,
and etching; 60°C
Reflective
Model
Top-view
Giga mode
Standard mode
E32-L11FP 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)
E32-L11FS 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)
Chemical/oil-resistant
E32-D12F 2M
Chemical-resistant
cable
E32-D11U 2M
--- *2
1,260
280
190
60
520
360
100
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing
method
Size
1.5 dia.
Through-beam
E32-T22B 2M
M3
E32-T21 2M
M4
E32-T11 2M
Square
32-T25XB 2M
1.5 dia.
E32-D22B 2M
M3
Reflective
Model
E32-D21 2M
3 dia.
E32-D221B 2M
M4
E32-D21B 2M
M6
Square
E32-D11 2M
E32-D25XB 2M
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode Super-high-speed mode
1,020
600
330
90
3,750
2,020
1,350
360
750
450
250
70
210
90
60
16
450
210
130
40
1,260
520
360
100
360
150
90
30
Standard mode
High-speed mode
Super-high-speed mode
2,400
1,200
840
225
4,000 *1
2,250
1,500
400
1,500
820
540
140
240
Heat-resistant Models
Sensing
method
Through-beam
Reflective
Heat-resistant temperature
Model
100°C
E32-T51R 2M
150°C
E32-T51 2M
200°C
E32-T81R-S 2M
Sensing distance (mm)
Giga mode
350°C
E32-T61-S 2M
2,520
1,350
900
100°C
E32-D51R 2M
1,000
420
280
80
150°C
E32-D51 2M
1,680
670
480
144
200°C
E32-D81R-S 2M
270
180
300°C
350°C
400°C
630
54
E32-A08H2 2M
10 to 20
---
E32-A09H2 2M
20 to 30 (center 25)
---
E32-D611-S 2M
E32-D61-S 2M
E32-D73-S 2M
630
270
180
54
420
180
120
36
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
11
E3NX-FA
Area Detection Models
Sensing
method
Through-beam
Reflective
Type
Sensing width
Array
Sensing distance (mm)
High-speed mode
Super-high-speed mode
E32-T16PR 2M
4,000 *1
2,550
1,680
440
E32-T16JR 2M
4,000 *1
2,250
1,440
380
30 mm
E32-T16WR 2M
4,000 *1
3,900
2,550
680
11 mm
E32-D36P1 2M
1,050
450
300
90
11 mm
Area
Model
Giga mode
Standard mode
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing
method
Tube-mounting
Liquid contact
(heat-resistant
up to 200°C)
Model
Sensing distance (mm)
Tube diameter
Feature
3.2, 6.4, or 9.5 dia
Stable residual
quantity detection
E32-A01 5M
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended
wall thickness: 1 mm
8 to 10 dia
Mounting at
multiple levels
E32-L25T 2M
Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall
thickness: 1 mm
No restrictions
Large tubes
E32-D36T 5M
Applicable tube: Transparent tube (no restrictions on diameter)
---
---
E32-D82F1 4M
Liquid-contact type
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
Vacuum-resistant Models
Sensing
method
Heat-resistant temperature
Model
E32-T51V 1M
Through-beam
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
1,080
600
390
Super-high-speed mode
100
120°C
E32-T51V 1M +
E39-F1V
2,000 *1
2,000 *1
2,000 *1
520
200°C
E32-T84SV 1M
2,000 *1
1,420
960
260
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing
method
Application
Glass presence
detection
Operating
temperature
70°C
Model
Sensing distance (mm)
Giga mode
300°C
70°C
Limitedreflective
Glass substrate
mapping
Super-high-speed mode
0 to 12
10 to 20
---
E32-A12 2M
12 to 30
---
E32-A09 2M
15 to 38
---
20 to 30 (center 25)
---
E32-A08H2 3M
300°C
E32-A09H2 2M
Wet processes:
Cleaning, Resist
developing and
etching
60°C
E32-L11FP 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)
Wet process: Resist
stripping
85°C
E32-L11FS 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)
E32-A03 2M
E32-A03-1 2M
Through-beam
High-speed mode
0 to 15
E32-L16-N 2M
E32-A08 2M
Glass substrate
alignment
Standard mode
Wafer mapping
70°C
E32-A04 2M
4,000 *1
2,670
1,800
500
1,920
1,020
670
200
E32-T24SR 2M
4,000 *1
3,300
2,190
580
E32-T24S 2M
4,000 *1
3,900
2,610
700
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
12
E3NX-FA
Infrared models
Threaded Models
Sensing
method
Through-beam
Sensing distance (mm)
Sensing direction
Size
Right-angle
M4
Straight
M3
Reflective
Straight
M6
Model
E32-T11N 2M
E32-T11R 2M
E32-C31 2M
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
280
190
130
55
50
37
25
8.5
E32-D11R 2M
120
90
60
21
E32-CC200 2M
200
150
100
35
Cylindrical Models
Sensing
method
Size
Through-beam
3 dia.
Reflective
3 dia.
Sensing
direction
Sensing distance (mm)
Model
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
Top-view
E32-T12R 2M
280
190
130
55
Side-view
E32-T14LR 2M
100
75
80
21
Top-view
E32-D32L 2M
100
75
50
17
Flat Models
Sensing distance (mm)
Sensing
method
Sensing direction
Top-view
E32-T15XR 2M
Through-beam
Side-view
E32-T15YR 2M
Flat-view
E32-T15ZR 2M
Reflective
Model
Top-view
E32-D15XR 2M
Side-view
E32-D15YR 2M
Flat-view
E32-D15ZR 2M
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
280
190
130
55
100
75
80
21
120
90
60
21
28
20
13
5
Sleeve Models
Sensing distance (mm)
Sensing
method
Sensing direction
Through-beam
Top-view
E32-TC200BR 2M
280
190
130
55
Reflective
Top-view
E32-DC200BR 2M
120
90
60
21
Model
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
High-power Beam Models
Sensing distance (mm)
Type
Sensing direction
Aperture angle
Through-beam
models with
integrated lens
Side-view
30°
Models
E32-T14 2M
Giga mode
1800
Standard mode
1200
High-speed
mode
820
Super-highspeed mode
360
13
E3NX-FA
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Light-ON
E3NX-FA11
E3NX-FA6
E3NX-FA11-5
E3NX-FAH11
E3NX-FAH6
Timing chart
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
E3NX-FA21
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
E3NX-FA7
E3NX-FA24
Dark-ON
Light-ON
E3NX-FA7TW
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
L/D indicator
L lit.
Dark-ON
Display OUT indicator (orange)
Brown
Load
Black
Control output
Photoelectric
sensor main
circuit
10 to
30 VDC
Blue
D lit.
L lit.
Display
OUT1
indicator
(orange)
OUT2 indicator
(orange)
Brown
Load
Black
Control output Load
Orange ch1
Control output
ch2
Pink
Photoelectric
sensor main
circuit
10 to
30 VDC
External
input
Blue
D lit.
Display OUT indicator (orange)
1
L lit.
4
Photoelectric
sensor main
circuit
3
D lit.
• M8 Connector Pin Arrangement
2
1
L lit.
Display
OUT1
indicator
(orange)
OUT2 indicator
(orange)
Photoelectric
sensor main
circuit
Brown
Load
Black
Control output
10 to
30 VDC
2
Orange
External
input
Blue
4
3
Brown
Load
Black
Control output Load
Orange ch1
Control output
ch2
10 to
30 VDC
Blue
D lit.
L lit.
Display OUT indicator (orange)
Brown
Black
Photoelectric
sensor main
circuit
E3NX-FA11AN
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
Output circuit
Load
Control output
Orange
Analog
output
Load 10kΩ min.
10 to
30 VDC
Blue
D lit.
14
E3NX-FA
PNP Output
Model
Operation
mode
Light-ON
E3NX-FA41
E3NX-FA8
E3NX-FAH41
E3NX-FAH8
Timing chart
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
L/D indicator
L lit.
Output circuit
Display OUT indicator (orange)
(Between blue and
black leads)
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Brown
Control
Black output
Photoelectric
sensor main
circuit
10 to
30 VDC
Load
Blue
D lit.
(Between blue and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
L lit.
OUT1
indicator
(orange)
(Between blue and
black (orange) leads)
E3NX-FA51
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Outputs
OFF
transistor
Operate
Load
(e.g., relay) Reset
Display
OUT2 indicator (orange)
Brown
External
Pink
input
Control output
Black
ch1
Control output
Orange ch2 Load
Photoelectric
sensor main
circuit
Blue
10 to
30 VDC
Load
D lit.
(Between blue and
black (orange) leads)
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Display OUT indicator (orange)
1
L lit.
2
Photoelectric
sensor main
circuit
(Between blue and
black leads)
E3NX-FA9
E3NX-FA54
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
4
External
Orange
input
Control
Black output
10 to
30 VDC
Load
3
D lit.
Brown
• M8 Connector Pin Arrangement
2
Blue
4
1
3
(Between blue and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Display
1
L lit.
(Between blue and
black (orange) leads)
E3NX-FA9TW
E3NX-FA54TW
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Outputs
OFF
transistor
Operate
Load
(e.g., relay) Reset
OUT2 indicator (orange)
OUT1
indicator
(orange)
Control output
Black
ch1
Control output
Orange ch2 Load
2
Photoelectric
sensor main
circuit
4
3
D lit.
Brown
• M8 Connector Pin Arrangement
2
1
Blue
10 to
30 VDC
Load
4
3
(Between blue and
black (orange) leads)
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
L lit.
Dark-ON
Brown
Orange Analog output
(Between blue and
black leads)
Photoelectric
sensor main
circuit
E3NX-FA41AN
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Display OUT indicator (orange)
10 to
30 VDC
Black Control output
Blue
Load
Load 10kΩ min.
D lit.
(Between blue and
black leads)
15
E3NX-FA
Plug (Sensor I/O Connector)
Terminal number
4
3
2
1
Wire color
Brown
White
Blue
Black
1
2
3
4
XS3F-M421-402-A
XS3F-M421-405-A
Wire color
Connection pin
Application
Brown
1
Power supply (+V)
White
2
External input / Output
Blue
3
Power supply (0 V)
Black
4
Output
XS3F-M422-402-A
XS3F-M422-405-A
Nomenclature
E3NX-FA11/FA41/FA6/FA8/FA7/FA9/FA24/FA54/
FA11-5/FAH11/FAH41/FAH6/FAH8/FA11AN/FA41AN
[L/D Indicator]
Indicates the setting status:
Light-ON (L) or Dark-ON (D).
[OUT Indicator]
Turns ON when the output is ON.
[
[DPC Indicator]
Turns ON when Dynamic
Power Control is effective.
[ L/D Button]
Use to switch between Light-ON (L)
and Dark-ON (D).
[ST Indicator]
Turns ON when Smart
Tuning is in progress.
Threshold Level Incident Level
White digital display
Green digital
display
Tune Button]
Executes Smart Tuning.
[ MODE Button]
Use to switch between Detection Mode and Setting Mode.
[+ −UP/DOWN Button]
Used to fine-tune the threshold or change set values.
E3NX-FA21/FA51/FA7TW/FA9TW/FA54TW/FA10/FA40/FA0/FAH0
[L/D Indicator]
Indicates the setting status:
Light-ON (L) or Dark-ON (D).
[OUT1 Indicator/OUT2 Indicator]
Turns ON when OUT1 or OUT2 is ON. *
[
Tune Button]
Executes Smart Tuning.
[DPC Indicator]
Turns ON when Dynamic Power
Control is effective.
[ L/D Button]
Use to switch between Light-ON (L) and Dark-ON (D).
[ST Indicator]
Turns ON when Smart
Tuning is in progress.
Threshold Level
Green digital display
Incident Level
White digital
display
[OUT1 Selection Indicator/OUT2 Selection Indicator]
The indicator for the selected output channel is lit. *
[ MODE Button]
Use to switch between Detection Mode and Setting Mode,
and use to switch between OUT1 and OUT2. (2 outputs)
[+ −UP/DOWN Button]
Used to fine-tune the threshold or change set values.
* Only OUT1 turns ON for output.
16
E3NX-FA
Safety Precautions
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.
Warning Indications
WARNING
Warning level
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally, there may be
significant property damage.
Precautions
for Safe Use
Supplementary comments on what to do or
avoid doing, to use the product safely.
Precautions
for Correct
Use
Supplementary comments on what to do or
avoid doing, to prevent failure to operate,
malfunction or undesirable effect on product
performance.
Meaning of Product Safety Symbols
General prohibition
Indicates the instructions of unspecified
prohibited action.
Caution, explosion
Indicates the possibility of explosion under
specific conditions.
Caution, fire
Indicates the possibility of fire under specific
conditions.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product with voltage in excess of the
rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply.
Otherwise, explosion may result.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation
of the Amplifier Unit. Doing so may cause damage or fire.
1. Do not install the product in the following locations.
• Locations subject to direct sunlight
• Locations subject to condensation due to high humidity
• Locations subject to corrosive gas
• Locations subject to vibration or mechanical shocks exceeding the
rated values
• Locations subject to exposure to water, oil, chemicals
• Locations subject to stream
• Locations subjected to strong magnetic field or electric field
2. Do not use the product in environments subject to flammable or
explosive gases.
3. Do not use the product in any atmosphere or environment that
exceeds the ratings.
4. To secure the safety of operation and maintenance, do not install
the product close to high-voltage devices and power devices.
5. High-voltage lines and power lines must be wired separately from
the product. Wiring them together or placing them in the same duct
may cause induction, resulting in malfunction or damage.
6. Do not apply any load exceeding the ratings. Otherwise, damage
or fire may result.
7. Do not short the load. Otherwise, damage or fire may result.
8. Connect the load correctly.
9. Do not miswire such as the polarity of the power supply.
10.To use this device as connecting with each other, be sure to
connect with the same power supply and turn ON the power
simultaneously. Using a separate power supply will influence the
functions when connecting the devices to use them.
11.Do not use the product if the case is damaged.
12.Burn injury may occur. The product surface temperature rises
depending on application conditions, such as the ambient
temperature and the power supply voltage. Attention must be paid
during operation or cleaning.
13.When setting the sensor, be sure to check safety such as by
stopping the equipment.
14.Be sure to turn off the power supply before connecting or
disconnecting wires.
15.Do not attempt to disassemble, repair, or modify the product in any
way.
16.When disposing of the product, treat it as industrial waste.
17.Do not use the Sensor in water, rainfall, or outdoors.
18.Use the product in the IP54 enclosure.
19.UL Standard Certification (Applicable Models: E3NX-FA11/21/41/51
Only)
Only the sensors with Enhanced UL Certification Mark are certified
by UL. They are intended to be supplied by a "Class 2 circuit". When
used in United States and Canada, Please use the same Class 2
source for input and output.The overcurrent protection current rating
is 2A max. They were evaluated as Open type and shall be installed
within a enclosure.
17
E3NX-FA
Precautions for Correct Use
1. Be sure to mount the unit to the DIN track until it clicks.
2. When using the Amplifier Units with Wire-saving Connectors,
attach the protective stickers (provided with E3X-CN-series
Connectors) on the unused power pins to prevent electrical shock
and short circuiting.
When using the Amplifier Units with Connectors for
Communications Units, attach the protective caps (provided with
E3NW-series Sensor Communications Unit).
Amplifier Unit with Wiresaving Connector
Amplifier Unit with Connector
for Communications Unit
Protective sticker
Power supply connecting
terminals
Protective cap
3. The length for the cable extension must be 30 m or less (or less
than 10 m for S-mark certified models). Be sure to use a cable of
at least 0.3 mm2 for extension. The power voltage must be 24 to
30 V when connecting amplifier units with extension cable and
wire-saving connector.
4. Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N
5. Do not apply excessive force such as tension, compression or
torsion to the Amplifier Unit with the Fiber Unit fixed to the Amplifier
Unit.
6. Always keep the protective cover in place when using the Amplifier
Unit. Not doing so may cause malfunction.
7. It may take time until the received light intensity and measured
value become stable immediately after the power is turned on
depending on use environment.
8. The product is ready to operate 200 ms after the power supply is
turned ON.
9. The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11S cannot be connected.
10.The mutual interference prevention function does not work when
in combination with E3C/E2C/E3X.
11.If the unit receives excessive sensor light, the mutual interference
prevention function may not work properly, resulting in malfunction
of the unit. In such case, increase the threshold.
12.Standard models and Advanced models
The Sensor Communication Unit E3X-DRT21-S, E3X-CRT, E3XECT and E3NW cannot be connected.
Model for Sensor Communication Unit (E3NX-FA0)
The Sensor Communication Unit E3NW can be connected.
E3X-DRT21-S, E3X-CRT, E3X-ECT cannot be connected.
13.If you notice an abnormal condition such as a strange odor,
extreme heating of the unit, or smoke immediately stop using the
product, turn off the power, and consult your dealer.
14.Do not use thinner, benzene, acetone, and lamp oil for cleaning.
18
E3NX-FA
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Pre-wired Amplifier Units
E3NX-FA@1(-5)
E3NX-FAH@1
E3NX-FA@AN
E3NX-FA11(-5)/FA41/
FAH@1/FA@1AN
L/D indicator
DPC indicator
21.7
*Cable Specifications
E3NX-FA21/FA51
ST indicator
21
27.1
Outer
No. of
Others
Model
diameter conductors
E3NX-FA11(-5)
E3NX-FA41
Conductor cross-section: 0.2 mm2
4.0 dia.
3
E3NX-FAH@1
Insulator dia.: 0.9 mm
E3NX-FA@1AN
Standard cable length: 2 m
E3NX-FA21
Minimum bending radius: 12 mm
4.0 dia.
5
E3NX-FA51
L/D
indicator
DPC
indicator
ST
indicator
OUT2 selection
indicator
27.8
OUT2 indicator
OUT1 indicator
OUT1 selection indicator
OUT indicator
Incident level
(white, digital)
Threshold level
(green, digital)
Threshold level (green, digital)
Incident level (white, digital)
With Mounting Bracket Attached
Mounted to DIN Track
10
5.1
5.1
147.1 (max. value with cover open)
71.8
170° (max. value with cover open)
104.8
(max. value
with cover
open)
Two,
2.4-dia.
fiber unit holes
4.5
33.5
33.5
(16.5)
(37)
3.4
5.7
*
(37.9)
Two, 3.2 dia.
(mounting holes)
(20.3)
Optical communications
(9.4)
20.5
71.8
PFP-@N DIN Track
(sold separately)
12.7
4.3
Optical communications
20.5
3.4
12.7
*
Fiber Attachment
(E39-F9) attached
(16.5)
(37)
16
4.4
E39-L143 Mounting Bracket
(sold separately, SUS304)
3.4
Mounting Holes
Two, M3 holes
(29.9)
16
Amplifier Units with Wire-saving Connectors
E3NX-FA6
E3NX-FA6/FA7(TW)/FA8
E3NX-FA7(TW)
/FA9(TW)/FAH6/FAH8
E3NX-FA8
E3NX-FA9(TW)
DPC indicator
ST indicator
E3NX-FAH6
L/D indicator
21.7
27.1
E3NX-FAH8
16
E3NX-FA7TW/FA9TW
L/D indicator
OUT2 selection indicator
DPC indicator
21
*Cable Specifications
27.8
Model
Outer diameter
E3X-CN12
2.6 dia.
ST indicator
OUT2 indicator
No. of conductors
1
2
E3X-CN22
OUT1 indicator
OUT indicator
E3X-CN11
Threshold level
(green, digital)
Incident level
(white, digital)
Threshold level (green, digital)
4
With Mounting Bracket Attached
147.1 (max. value with cover open)
5.1
3
Incident level (white, digital)
Mounted to DIN Track
10
4.0 dia.
E3X-CN21
OUT1 selection indicator
(75.3)
5.1
170° (max. value with cover open)
104.8
(max. value
with cover
open)
4.5
Two,
2.4-dia.
fiber unit holes
33.5
33.5
(16.5)
(16.5)
(37)
(37)
3.4
*
5.7
With Fiber Attachment
(E39-F9) attached
(13)
*
4.3
Optical communications
20.5
(37.9)
(23.8)
(75.3)
3.4
Two, 3.2 dia.
(mounting holes)
Wire-saving Connector
(sold separately)
20.5
PFP-@N DIN Track
(sold separately)
(9.4)
16
4.4
3.4
(13)
Wire-saving Connector
(sold separately)
Optical communications
E39-L143 Mounting Bracket
(sold separately, SUS304)
Mounting Holes
Two, M3 holes
(29.9)
16
16
19
E3NX-FA
Amplifier Units with M8 Connectors
E3NX-FA24
E3NX-FA24/FA54
E3NX-FA54
E3NX-FA54TW
L/D indicator
DPC indicator
E3NX-FA54TW
ST indicator
21.7
27.1
21
27.8
OUT2 indicator
4.2
6.9
5.2
OUT indicator
Threshold level (green, digital)
ST indicator
Incident level
(white, digital)
Threshold level
(green, digital)
147.1 (max. value with cover open)
5.1
Two,
2.4-dia.
fiber unit holes
4.5
1
3
71.8
170° (max. value with cover open)
104.8
(max. value
with cover
open)
4
With Mounting Bracket Attached
Mounted to DIN Track
5.1
2
OUT1 indicator
OUT1 selection indicator
Incident level
(white, digital)
10
Connector pin
arrangement
L/D indicator
DPC indicator
OUT2 selection indicator
33.5
(16.5)
(37)
(5.7)
3.4
4.9
12.7
3.4
5.7
4.8
20.5
20.5
M8 Connector
(37.9)
(20.3)
Two, 3.2 dia.
(mounting holes)
71.8
(9.4)
4.3
16
(37.9)
(20.5)
E39-L143 Mounting Bracket (sold separately, SUS304)
PFP-@N DIN Track
(sold separately)
Optical communications
4.4
3.4
Mounting Holes
Two, M3 holes
(29.9)
16
16
Amplifier Unit with Connector for Sensor Communications Unit
E3NX-FA0/FAH0
OUT2 selection indicator
L/D indicator
DPC indicator
ST indicator
OUT2 indicator
21
27.8
OUT1 indicator
OUT1 selection indicator
Threshold level (green, digital)
Incident level (white, digital)
Mounted to DIN Track
13.8
E3NX-FA0/FAH0
11.5
10
E3NX-FA10/FA40
5.1
5.1
140 (max. value with cover open)
140 (max. value with cover open)
152° (max. value with cover open)
104.8
(max. value
with cover
open)
4.5
Two,
2.4-dia.
fiber unit
holes
33.5
(37)
33.5
(16.5)
26
(29.9)
3.4
5.7
With Fiber Attachment
(E39-F9) attached
152° (max. value with cover open)
Optical
communications
(39.3)
20.5
(37.9)
(37)
(16.5)
(5.7)
3.4
With Fiber Attachment
(E39-F9) attached
26
(29.9)
20.5
(37.9)
Optical
communications
96.9
90.8
PFP-@N DIN Track
(sold separately)
(45.4)
PFP-@N DIN Track
(sold separately)
101.4
20
E3NX-FA
Accessories (Sold Separately)
Wire-saving Connectors
Master
Connector
E3X-CN11
E3X-CN21
2,000+500
Edge of Amplifier Unit
(7)
*
* E3X-CN11: 4-dia. cable with 3 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. cable with 4 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Slave
Connector
E3X-CN12
E3X-CN22
2,000+50
0
Edge of Amplifier Unit
(7)
*
* E3X-CN12: 2.6-dia. cable with 1 conductor, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. cable with 2 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Sensor I/O Connectors
Straight
XS3F-M421-40@-A
2.15 M8
4
2
3
1
12.9
4 dia.
9 dia.
1.95 0.5
21.5
3.4
30
5
50
31.4
L
L-shaped
XS3F-M422-40@-A
50
L
23.1
20.5
30
5
4 dia.
9 dia.
3.4
2.15
0.5
1.95
21
E3NX-FA
Mounting Bracket
E39-L143
34.8
22
16
2.5
(10.3)
3
Mounting Holes
7.3
5.3
Two, M3 holes
26.8
3.2 -dia. holes
3
16
7
16±0.1
3
Four, Radius: 1.7
10.3 10 max. 7
3.4
Material: Stainless steel (SUS304)
1
3.4
1
DIN Track
PFP-100N
PFP-50N
7.3±0.15
4.5
35±0.3
15
25
10
25
25
1,000 (500)*
25
10
27±0.15
15 (5)*
1
*Dimensions in parentheses are for the PFP-50N.
Material: Aluminum
PFP-100N2
16
4.5
35±0.3 27
15
25
25
10
25
1,000
10
25
15
24
29.2
1
1.5
Material: Aluminum
End Plate
PFP-M
11.5
50
M4×8
panhead screw
10
M4 spring washer
4.8
6.2
10
1
1.3
1.8
35.5
Materials: Iron, zinc plating
1.8
35.3
22
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2018.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/