E3NX-MA41

E3NX-MA41

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    FIBER AMP 2CH STD PNP 2M CBL

  • 数据手册
  • 价格&库存
E3NX-MA41 数据手册
Smart Fiber Amplifier Units E3NX-MA 2-channel Amplifier reduces installation space by half. Downsized Equipment and Control Panels • The new 2-ch fiber amplifier unit has two-unit functions in the dimensions of the general one-unit, contributing to downsizing your equipment and control panels. • Performance with highly stable detection even with two channels, from transparent objects to low-reflective workpieces. • Easy to set the light intensity and threshold automatically. • Wire-saving Connector models reduce wiring work. Refer to the Safety Precautions on page 10. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Fiber Amplifier Units (Dimensions ➜ pages 12 and 13) Type Connecting method Appearance Inputs/outputs Model NPN output PNP output Pre-wired (2 m) 2 outputs E3NX-MA11 E3NX-MA41 Wire-saving Connector 2 outputs E3NX-MA6 E3NX-MA8 Standard Type 2-channel models *2 Connector for Model for Sensor Sensor Communications Communications Unit *1 Unit --- E3NX-MA0 *1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network. *2. Two Fiber Units can be connected to one Fiber Amplifier Unit. 1 E3NX-MA Accessories (Sold Separately) Wire-saving Connectors (Required for models for Wire-saving Connectors.) (Dimensions ➜ page 13) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. *Protective stickers are provided. Type Appearance Cable length No. of conductors Model 4 E3X-CN21 Master Connector Applicable Fiber Amplifier Units E3NX-MA6 E3NX-MA8 2m Slave Connector 2 Mounting Bracket (Dimensions ➜ page 14) A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. Appearance Model Quantity E39-L143 1 DIN Track (Dimensions ➜ page 14) A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. Appearance Type Model PFP-100N Shallow type, total length: 0.5 m PFP-50N Deep type, total length: 1 m PFP-100N2 2 Type Appearance Model Sensor Communications Unit for EtherCAT E3NW-ECT Sensor Communications Unit for CC-Link E3NW-CCL Distributed Sensor Unit * E3NW-DS Refer to your OMRON website for details. * The Distributed Sensor Unit can be connected to any of the Sensor Communications Units. Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required. PFP-M Sensor Communications Units 1 End Plate (Dimensions ➜ page 14) Model Related Products Quantity Shallow type, total length: 1 m Appearance E3X-CN22 Quantity 1 EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association. E3NX-MA Ratings and Specifications Type Item Inputs/ outputs Model for Sensor Communications Unit Standard Type NPN output E3NX-MA11 E3NX-MA6 PNP output E3NX-MA41 E3NX-MA8 Connecting method Pre-wired Wire-saving Connector Outputs E3NX-MA0 Connector for Sensor Communications Unit 2 outputs External inputs --- --- *1 --- Light source (wavelength) Red, 4-element LED (625 nm) Power supply voltage 10 to 30 VDC, including 10% ripple (p-p) Power consumption *2 At Power supply voltage of 24 VDC Normal mode : 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO : 870 mW max. (Current consumption at 36 mA max.) Control output Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. Indicators 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange) Protection circuits Power supply reverse polarity Power supply reverse polarity protection, output short-circuit protection, protection and output shortcircuit and output reverse polarity protection protection Response time ( Super-high-speed mode (SHS) Operate or reset: 100 μs High-speed mode (HS) Operate or reset: 450 μs Standard mode (Stnd) Operate or reset: 1ms Giga-power mode (GIGA) Operate or reset: 16ms Supplied from the connector through the Sensor Communications Unit --- ) Sensitivity adjustment Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (−99% to 99%)) or manual adjustment Maximum connectable Units 30 No. of Units for mutual interference prevention *4 9 Note: The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. With E3NW-ECT: 30 units *3 With E3NW-CCL: 16 units *1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table. PLC operation via Communications Unit enables reading detected values and changing settings. *2. Power consumption At Power supply voltage of 10 to 30 VDC Standard Models: Normal mode : 1080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC) Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC) Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC) *3. When connected to an OMRON NJ-series Controller. *4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC. Check the mutual interference prevention unit count and response speed of each model. 3 E3NX-MA Type Item Model for Sensor Communications Unit Standard Type NPN output E3NX-MA11 E3NX-MA6 PNP output E3NX-MA41 E3NX-MA8 Connecting method Pre-wired Wire-saving Connector E3NX-MA0 Connector for Sensor Communications Unit Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings Select from initial reset (factory defaults) or user reset (saved settings). *5 Functions Eco mode Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). Sensor OFF setting --- Select from banks 1 to 4. Power tuning Select from ON or OFF. Output 1 Select from normal detection mode or area detection mode. Output 2 Select from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode. Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. Operating: Groups of 1 or 2 Amplifier Units: −25 to 55°C, Groups of 3 to 10 Amplifier Units: −25 to 50°C, Ambient temperature range *6 Groups of 11 to 16 Amplifier Units: −25 to 45°C, Groups of 17 to 30 Amplifier Units: −25 to 40°C Storage: −30 to 70°C (with no icing or condensation) Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) Ambient humidity range Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above Altitude 2,000 m max. Installation environment Pollution degree 3 Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP50 (with Protective Cover attached) Weight (packed state/Sensor only) Approx. 115 g/ approx. 75 g Case Materials Cover Cable Accessories Approx. 60g/ approx. 20g Polycarbonate (PC) Polycarbonate (PC) PVC Instruction Manual *5. The bank is not reset by the user reset function or saved by the user save function. *6. When the number of connected units is 11 or more, the ambient temperature is less than 50°C. 4 Select from ON or OFF. Bank switching 150 m/s2 for 3 times each in X, Y, and Z directions Approx. 65 g/ approx. 25 g E3NX-MA Sensing Distances Threaded Models Sensing method Sensing direction Size Right-angle Throughbeam Aperture angle 60° Straight M4 Right-angle 15° Straight M3 M4 Right-angle M6 Reflective 60° 15° M3 60° M4 Straight Model High-speed mode Super-high-speed mode 1,870 910 700 E32-T11R 2M 1,870 910 700 180 E32-LT11 2M 4,000 *1 3,510 2,700 700 E32-LT11N 2M 4,000 *1 2,990 2,300 590 E32-LT11R 2M 4,000 *1 2,990 2,300 590 E32-C31N 2M 100 44 32 9 E32-C21N 2M 480 190 140 43 E32-D21N 2M 800 320 240 72 E32-C11N 2M 740 310 240 66 E32-LD11N 2M 790 310 240 71 E32-D21R 2M 130 57 40 11 E32-C31 2M 330 130 100 30 E32-C31M 1M 330 130 100 30 E32-D211R 2M 130 57 40 11 800 320 240 72 1,340 540 400 120 E32-CC200 2M 15° Standard mode E32-T11N 2M E32-D11R 2M M6 Sensing distance (mm) Giga mode 180 E32-LD11 2M 820 330 250 74 E32-LD11R 2M 790 310 240 71 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Cylindrical Models Sensing method Sensing direction Size 1 dia. Throughbeam Reflective Model Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode E32-T223R 2M 520 260 150 45 Top-view E32-T22B 2M 750 370 220 65 E32-T12R 2M 1,870 910 700 180 Side-view E32-T14LR 2M 690 330 260 67 1.5 dia. E32-D22B 2M 130 57 40 11 1.5 dia. + 0.5 dia. E32-D43M 1M 29 12 8 2 E32-D22R 2M 130 57 40 11 1.5 dia. 3 dia. Top-view 3 dia. 3 dia. + 0.8 dia. E32-D221B 2M 310 120 90 26 E32-D32L 2M 680 280 200 58 E32-D33 2M 68 28 20 5 Flat Models Sensing method Sensing direction Model Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode Throughbeam Top-view E32-T15XR 2M 1,870 910 700 Side-view E32-T15YR 2M 690 330 260 180 67 Flat-view E32-T15ZR 2M 690 330 260 67 Top-view E32-D15XR 2M 800 320 240 72 Reflective Side-view E32-D15YR 2M 180 76 52 16 Flat-view E32-D15ZR 2M 180 76 52 16 Sleeve Models Sensing method Throughbeam Sensing direction Side-view Top-view Side-view Reflective Top-view Model Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode E32-T24R 2M 140 71 50 E32-T24E 2M 450 220 150 39 E32-T21-S1 2M 510 250 170 44 1,870 910 700 180 68 28 20 5 150 64 45 13 2 E32-TC200BR 2M E32-D24R 2M E32-D24-S2 2M 12 E32-D43M 1M 29 12 8 E32-D331 2M 13 5 4 1 E32-D33 2M 68 28 20 5 E32-D32-S1 0.5M 68 28 18 5 E32-D31-S1 0.5M 68 28 20 5 130 57 40 11 E32-DC200F4R 2M E32-D22-S1 2M 220 96 72 19 E32-D21-S3 2M 220 96 72 19 E32-DC200BR 2M 800 320 240 72 E32-D25-S3 2M 220 96 72 19 5 E3NX-MA Small-spot, Reflective Models Type Spot diameter Center distance (mm) Variable spot 0.1 to 0.6 dia. 0.3 to 1.6 dia. 6 to 15 10 to 30 Parallel light 4 dia. 0 to 20 Integrated lens 0.1 dia. 5 E32-C42 1M + E39-F3A E32-C42 1M + E39-F17 E32-C31 2M + E39-F3C E32-C21N 2M + E39-F3C E32-C42S 1M 6 dia. 50 E32-L15 2M 0.1 dia. 7 0.5 dia. Small-spot Models 0.2 dia. 17 0.5 dia. 3 dia. 50 E32-C41 1M + E39-F3A-5 E32-C31 2M + E39-F3A-5 E32-C21N 2M + E39-F3A-5 E32-C41 1M + E39-F3B E32-C31 2M + E39-F3B E32-C21N 2M + E39-F3B E32-CC200 2M + E39-F18 E32-C11N 2M + E39-F18 Sensing distance (mm) High-speed Giga mode Standard mode mode Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. Spot diameter of 4 mm max. at 0 to 20 mm. Spot diameter of 0.2 mm at 17 mm. Spot diameter of 0.1 mm at 5 mm. Spot diameter of 6 mm at 50 mm. (For all the sensing distance modes (40 to 100mm)) Spot diameter of 0.1 mm at 7 mm. Super-highspeed mode Spot diameter of 0.5 mm at 7 mm. Spot diameter of 0.2 mm at 17 mm. Spot diameter of 0.5 mm at 17 mm. Spot diameter of 3 mm at 50 mm. High-power Beam Models Type Sensing direction Aperture angle Right-angle Through-beam models with integrated lens 15° 10° Top-view Right-angle Top-view Side-view Top-view Side-view Through-beam models with lenses Top-view Side-view Top-view Side-view Top-view Side-view Top-view Reflective models with integrated lens 30° 12° 6° 12° 6° 60° 12° 6° 60° 12° 6° 60° 12° 6° 60° 12° 6° 60° 12° 6° E32-LT11N 2M E32-T17L 10M E32-LT11 2M E32-LT11R 2M E32-T14 2M E32-T11N 2M + E39-F1 E32-T11N 2M + E39-F16 E32-T11R 2M + E39-F1 E32-T11R 2M + E39-F16 E32-T11R 2M + E39-F2 E32-T11 2M + E39-F1 E32-T11 2M + E39-F16 E32-T11 2M + E39-F2 E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51R 2M + E39-F2 E32-T81R-S 2M + E39-F1 E32-T81R-S 2M + E39-F16 E32-T81R-S 2M + E39-F2 E32-T61-S 2M + E39-F1 E32-T61-S 2M + E39-F16 E32-T61-S 2M + E39-F2 E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 4° E32-D16 2M 15° Side-view Top-view Models Giga mode 4,000 *2 20,000 *1 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 1,680 4,000 *2 4,000 *2 2,170 4,000 *2 4,000 *2 1,430 4,000 *2 4,000 *2 860 4,000 *2 4,000 *2 1,440 4,000 *2 4,000 *2 40 to 4,000 *2 Sensing distance (mm) High-speed mode 2,990 2,300 20,000 *1 20,000 *1 3,510 2,700 2,990 2,300 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 4,000 *2 810 630 4,000 *2 4,000 *2 4,000 *2 4,000 *2 1,050 810 2,850 2,190 4,000 *2 4,000 *2 690 530 3,270 2,520 4,000 *2 4,000 *2 420 320 4,000 *2 4,000 *2 4,000 *2 4,000 *2 700 540 2,990 2,300 4,000 *2 4,000 *2 Standard mode 40 to 2,100 Super-highspeed mode 590 5,200 700 590 1,160 1,270 2,290 1,270 2,290 160 1,630 2,940 210 570 1,830 130 650 1,170 84 1,090 1,960 140 590 3,270 40 to 1,350 40 to 480 Sensing distance (mm) High-speed Standard mode mode 1,560 1,200 1,560 1,200 580 450 1,910 1,460 2,270 1,740 3,250 2,500 Super-highspeed mode 310 310 110 380 450 650 *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. *2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Narrow View Models Sensing method Sensing direction Aperture angle 1.5° Through-beam 3.4° Side-view 4° Models Giga mode E32-A03 2M E32-A03-1 2M E32-A04 2M E32-T24SR 2M E32-T24S 2M E32-T22S 2M 3,210 3,210 1,200 3,930 4,000 *1 4,000 *1 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Models for Detection without Background Interference Sensing method Limitedreflective 6 Sensing direction Flat-view Side-view Model E32-L16-N 2M E32-L24S 2M E32-L25L 2M Giga mode Sensing distance (mm) High-speed mode 0 to 15 0 to 4 5.4 to 9 (center 7.2) Standard mode Super-highspeed mode 0 to 12 E3NX-MA Transparent Object Detection (Retro-reflective Models) Sensing method Retro-reflective Sensing distance (mm) Feature Size Models Film detection M3 E32-C31 2M+ E39-F3R+E39-RP37 Square --- E32-R16 5M Giga mode Standard mode M6 E32-LR11NP 2M+ E39-RP1 Super-highspeed mode 200 --- 1,000 360 230 150 to 1,500 E32-R21 2M Threaded Hex-shaped High-speed mode 10 to 250 1,280 1,080 Transparent Object Detection (Limited-reflective Models) Sensing method Limitedreflective Sensing direction Feature Sensing distance (mm) Model Giga mode Standard mode High-speed mode Super-highspeed mode Small size E32-L24S 2M Standard E32-L16-N 2M 0 to 15 0 to 12 E32-A08 2M 15 to 25 --- E32-A12 2M 12 to 30 --- Glass substrate alignment, 70°C Flat-view Standard/ long-distance Side-view form Side-view E32-L25L 2M Glass substrate mapping, 70°C Top-view E32-A09 2M 0 to 4 5.4 to 9 (center 7.2) 15 to 38 --- Chemical-resistant, Oil-resistant Models Sensing method Through-beam Type Sensing direction Oil-resistant Right-angle Chemical/oil-resistant Chemical/oil-resistant at 150°C Semiconductors: Resist stripping; 85°C Giga mode Standard mode High-speed mode Super-highspeed mode E32-T11NF 2M 4,000 *1 4,000 *1 4,000 *1 1,340 E32-T12F 2M 4,000 *1 4,000 *1 4,000 *1 1,040 E32-T11F 2M 4,000 *1 3,380 2,600 670 Side-view E32-T14F 2M 1,340 650 500 130 Top-view E32-T51F 2M 4,000 *1 2,340 1,800 460 Top-view Semiconductors: Cleaning, developing, and etching; 60°C Reflective Sensing distance (mm) Model Top-view E32-L11FP 2M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) E32-L11FS 2M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) Chemical/oil-resistant E32-D12F 2M Chemical-resistant cable E32-D11U 2M --- *2 800 170 130 39 320 240 72 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. *2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin. Bending-resistant Models Sensing method Sensing distance (mm) Size 1.5 dia. Through-beam Giga mode Standard mode High-speed mode Super-highspeed mode E32-T22B 2M 750 370 220 65 M3 E32-T21 2M 670 330 220 58 M4 E32-T11 2M 2,410 1,170 900 230 Square E32-T25XB 2M 500 250 170 43 1.5 dia. E32-D22B 2M 130 57 40 11 E32-D21 2M 130 57 40 11 3 dia. E32-D221B 2M 310 120 90 26 M4 E32-D21B 2M 310 120 90 26 M6 E32-D11 2M 800 320 240 72 E32-D25XB 2M 220 92 60 18 M3 Reflective Model Square 7 E3NX-MA Heat-resistant Models Sensing method Heat-resistant temperature 100°C 150°C 200°C 350°C 100°C 150°C 200°C Through-beam Reflective Model E32-T51R 2M E32-T51 2M E32-T81R-S 2M E32-T61-S 2M E32-D51R 2M E32-D51 2M E32-D81R-S 2M E32-A08H2 2M E32-A09H2 2M E32-D61-S 2M E32-D73-S 2M 300°C 350°C 400°C Sensing distance (mm) High-speed Giga mode Standard mode mode 1,500 720 560 2,680 1,300 1,000 960 460 360 1,600 780 600 640 250 190 1,070 430 320 380 150 120 15 to 25 20 to 30 (center 25) 380 150 120 250 100 80 Super-highspeed mode 140 260 93 150 57 96 34 ----34 22 Sensing distance (mm) High-speed mode 1,460 1,120 1,260 970 2,240 1,720 270 200 Super-highspeed mode 290 250 440 60 Area Detection Models Sensing method Type Through-beam Area Reflective Array Sensing width 11 mm 30 mm 11 mm Model Giga mode E32-T16PR 2M E32-T1s6JR 2M E32-T16WR 2M E32-D36P1 2M Standard mode 3,010 2,610 4,000 *1 670 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Liquid-level Detection Models Sensing method Tube diameter 3.2, 6.4, or 9.5 dia Tube-mounting 8 to 10 dia No restrictions Liquid contact (heat-resistant up to 200°C) Feature Model Stable residual E32-A01 5M quantity detection Mounting at E32-L25T 2M multiple levels Large tubes E32-D36T 2M --- --- E32-D82F1 4M Sensing distance (mm) High-speed Super-highmode speed mode Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm Applicable tube: Transparent tube (no restrictions on diameter) Giga mode Standard mode Liquid-contact type Vacuum-resistant Models Sensing method Heat-resistant temperature E32-T51V 1M E32-T51V 1M+E39-F1V E32-T84SV 1M 120°C Through-beam Sensing distance (mm) High-speed Giga mode Standard mode mode 690 330 260 2,000 *1 1,760 1,360 1,710 830 640 Model 200°C Super-highspeed mode 67 350 160 *1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm. Models for FPD, Semiconductors, and Solar Cells Sensing method Application Glass presence detection Through-beam 70°C Model 300°C Wet processes: Cleaning, Resist developing and etching 60°C E32-L11FP 2M Wet process: Resist stripping 85°C E32-L11FS 2M 70°C E32-A03 2M E32-A03-1 2M E32-A04 2M E32-T24SR 2M E32-T24S 2M Glass substrate mapping Wafer mapping 300°C 70°C Giga mode E32-L16-N 2M E32-A08 2M E32-A08H2 2M E32-A12 2M E32-A09 2M E32-A09H2 2M Glass substrate alignment Limitedreflective Operating temperature 0 to 15 Super-highspeed mode 0 to 12 --15 to 25 --15 to 25 --12 to 30 --15 to 38 --20 to 30 (center 25) 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) 3,210 1,560 1,200 310 3,210 1,560 1,200 310 1,200 580 450 110 3,930 1,910 1,460 380 4,000 *1 2,270 1,740 450 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 8 Sensing distance (mm) High-speed Standard mode mode E3NX-MA I/O Circuit Diagrams NPN Output Model Operation mode Timing chart Light-ON ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) E3NX-MA11 E3NX-MA6 Dark-ON Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Operation mode Timing chart L/D indicator L lit. Output circuit OUT2 indicator (orange) Display OUT1 indicator (orange) Brown Load Black Control output Load Orange ch1 Control output ch2 Photoelectric sensor main circuit 10 to 30 VDC Blue D lit. PNP Output Model Light-ON L/D indicator ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset L lit. Dark-ON OUT2 indicator (orange) Display OUT1 indicator (orange) (Between blue and black (orange) leads) E3NX-MA41 E3NX-MA8 Output circuit Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Outputs OFF transistor Operate Load (e.g., relay) Reset Photoelectric sensor main circuit Brown Control output ch1 Black Control output Orange ch2 Load Blue 10 to 30 VDC Load D lit. (Between blue and black (orange) leads) Nomenclature E3NX-MA11/MA41/MA6/MA8/MA0 [L/D Indicator] Indicates the setting status: Light-ON (L) or Dark-ON (D). [OUT1 Indicator/OUT2 Indicator] Turns ON when OUT1 or OUT2 is ON. [ Tune Button] Executes Smart Tuning. [DPC Indicator] Turns ON when Dynamic Power Control is effective. [ L/D Button] Use to switch between Light-ON (L) and Dark-ON (D). [ST Indicator] Turns ON when Smart Tuning is in progress. Threshold Level Green digital display Incident Level White digital display [OUT1 Selection Indicator/OUT2 Selection Indicator] The indicator for the selected output channel is lit. [ MODE Button] Use to switch between Detection Mode and Setting Mode, and use to switch between OUT1 and OUT2. [+ −UP/DOWN Button] Used to fine-tune the threshold or change set values. 9 E3NX-MA Safety Precautions Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/. Warning Indications WARNING Warning level Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols General prohibition Indicates the instructions of unspecified prohibited action. Caution, explosion Indicates the possibility of explosion under specific conditions. Caution, fire Indicates the possibility of fire under specific conditions. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explosion may result. 10 Precautions for Safe Use The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire. 1. Do not install the product in the following locations. • Locations subject to direct sunlight • Locations subject to condensation due to high humidity • Locations subject to corrosive gas • Locations subject to vibration or mechanical shocks exceeding the rated values • Locations subject to exposure to water, oil, chemicals • Locations subject to steam • Locations subject to strong magnetic field or electric field 2. Do not use the product in environments subject to flammable or explosive gases. 3. Do not use the product in any atmosphere or environment that exceeds the ratings. 4. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. 5. High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. 6. Do not apply any load exceeding the ratings. Otherwise damage or fire may result. 7. Do not short the load. Otherwise damage or fire may result. 8. Connect the load correctly. 9. Do not miswire such as the polarity of the power supply. 10. To use this device as connecting with each other, be sure to connect with the same power supply and turn ON the power simultaneously. Using a separate power supply will influence the functions when connecting the devices to use them. 11. Do not use the product if the case is damaged. 12. Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning. 13. When setting the sensor, be sure to check safety such as by stopping the equipment. 14. Be sure to turn off the power supply before connecting or disconnecting wires. 15. Do not attempt to disassemble, repair, or modify the product in any way. 16. When disposing of the product, treat it as industrial waste. 17. Do not use the Sensor in water, rain, or outdoors. 18. Use the product in the IP54 enclosure. 19. UL Standard Certification Only the Sensors with the Enhanced UL Certification Mark are certified by UL. They are intended to be supplied by a "Class 2 circuit". When used in United States and Canada, please use the same Class 2 source for input and output. The overcurrent protection current rating is 2 A max. They were evaluated as Open type and shall be installed within a enclosure. E3NX-MA Precautions for Correct Use 1. Be sure to mount the unit to the DIN track until it clicks. 2. When using the Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with E3NW-series Sensor Communications Units). Amplifier Unit with Wire-saving Connector Amplifier Unit with Connector for Communications Unit Protective sticker Power supply connecting terminals Protective cap 3. The length for the cable extension must be 30 m or less (or less than 10 m for S-mark certified models). Be sure to use a cable of at least 0.3 mm2 for extension. The power voltage must be 24 to 30 V when connecting amplifier units with extension cable and wire-saving connector. 4. Do not apply the forces on the cable exceeding the following limits: Pull: 40 N; torque: 0.1 N·m; pressure: 20 N; bending: 29.4 N 5. Use the E32- Fiber Unit. 6. Do not apply excessive force such as tension, compression or torsion to the Fiber Amplifier Unit with the Fiber Unit fixed to the Fiber Amplifier Unit. 7. Always keep the protective cover in place when using the product. Not doing so may cause malfunction. 8. It may take time until the incident level and measurement value become stable immediately after the power is turned on depending on use environment. 9. The product is ready to operate 200 ms after the power supply is turned ON. 10. The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3XMC11-S cannot be connected. 11. The mutual interference prevention function does not work when in combination with E3C/E2C/E3X. 12. Excessive incident light cannot be sufficiently handled by the mutual interference prevention function and may cause malfunction. To prevent this, set a higher threshold level. 13. The Communication Unit E3X-DRT21-S, E3X-CRT and E3X-ECT cannot be connected. 14. If using one CH only, do not wire the output cable of the CH unused. The output value might not be correct due to the change of the receiving light amount of the CH unused. 15. If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the product, turn off the power, and consult your dealer. 16. Do not use thinner, benzine, acetone, and lamp oil for cleaning. 11 E3NX-MA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Fiber Amplifier Units Pre-wired Amplifier Units E3NX-MA11 E3NX-MA41 OUT2 selection indicator L/D indicator 21 4.2 OUT2 indicator *1. The Mounting Bracket can also be used on side B. *2. Cable Specifications DPC indicator No. of Outer diameter conductors Model ST indicator 27.8 (B) *1 E3NX-MA11 4.0 dia. 10 6.9 OUT1 indicator OUT1 selection indicator Threshold level (green, digital) 4 E3NX-MA41 Others Conductor cross-section: 0.2 mm2 Insulator dia.: 0.9 mm 5.2 Incident level (white, digital) With Mounting Bracket Attached 10 5.1 147.1 (max. value with cover open) 170° (max. value with cover open) 104.8 (max. value with cover open) Four, 2.4 dia. fiber unit holes 4.5 33.5 (16.5) (5.7) (37) 4.9 3.4 *2 5.7 4.8 Fiber Attachment (E39-F9) attached (9.4) 20.5 16 12.7 3.4 4.3 Optical communications (20.5) (37.9) 46.1 71.8 Two, 3.2 dia. (mounting holes) 0.25 1.5 20.5 71.8 Mounting Bracket (E39-L143) (sold separately) [SUS304 stainless steel] 4.4 3.4 Mounting Holes Two, M3 holes (29.9) 16 16 Amplifier Units with Wire-saving Connectors E3NX-MA6 E3NX-MA8 OUT2 selection indicator L/D indicator 21 4.2 OUT2 indicator *1. The Mounting Bracket can also be used on side B. *2. Cable Specifications DPC indicator ST indicator 27.8 Model (B) *1 10 4.0 dia. E3X-CN21 6.9 OUT1 indicator OUT1 selection indicator Threshold level (green, digital) Outer diameter E3X-CN22 5.2 Incident level (white, digital) With Mounting Bracket Attached 10 5.1 147.1 (max. value with cover open) 170° (max. value with cover open) 104.8 (max. value with cover open) 4.5 Four, 2.4 dia. fiber unit holes 33.5 (37) (5.7) (16.5) 4.9 3.4 *2 5.7 4.8 With Fiber Attachment (E39-F9) attached 20.5 (9.4) 16 (37.9) 4.3 (23.8) (13) Wire-saving Connector (sold separately) Optical communications Mounting Bracket (E39-L143) (sold separately) [SUS304 stainless steel] 4.4 3.4 Mounting Holes Two, M3 holes 16 12 (29.9) 16 0.25 1.5 20.5 75.3 Two, 3.2 dia. (mounting holes) 3.4 46.1 71.8 No. of conductors 2 4 E3NX-MA Amplifier Unit with Connector for Sensor Communications Unit E3NX-MA0 OUT2 selection indicator L/D indicator 21 DPC indicator ST indicator 27.8 OUT2 indicator 5.2 10 6.9 4.2 Incident level (white, digital) OUT1 indicator Threshold level (green, digital) OUT1 selection indicator 13.8 11.5 Mounted to DIN Track 10 5.1 140 (max. value with cover open) 152° (max. value with cover open) 104.8 (max. value with cover open) Four, 2.4 dia. fiber unit holes (37) 33.5 4.5 5.7 4.8 (5.7) (16.5) 26 29.9 3.4 Fiber Attachment (E39-F9) attached 4.9 3.4 20.5 (39.3) (37.9) 90.8 DIN Track (Sold separately.) PFP-N Optical communications 0.25 1.5 20.5 46.1 71.8 Accessories (Sold Separately) Wire-saving Connectors Master Connector E3X-CN21 2,000+500 Edge of Amplifier Unit (7) * * 4-dia. cable with 4 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Slave Connector E3X-CN22 2,000+500 Edge of Amplifier Unit (7) * * 4-dia. cable with 2 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) 13 E3NX-MA Mounting Bracket E39-L143 34.8 22 16 2.5 (10.3) 3 Mounting Holes 7.3 5.3 Two, M3 holes 26.8 Two, 3.2 dia. holes 3 16 3 7 16±0.1 Four, Radius: 1.7 3.4 10.3 10 max.7 Material: Stainless steel (SUS304) 1 3.4 1 DIN Track PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500) * 15 (5) * 25 10 27±0.15 1 * Dimensions in parentheses are for the PFP-50N. Material: Aluminum PFP-100N2 16 4.5 35±0.3 27 15 25 25 10 25 1,000 10 25 15 11.5 50 M4×8 panhead screw 10 M4 spring washer 4.8 6.2 1 1.3 1.8 35.5 Materials: Iron, zinc plating 14 35.3 1.8 29.2 1 Material: Aluminum End Plate PFP-M 24 10 1.5 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2017 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_5_0420 Cat. No. E467-E1-01 1217(1217)
E3NX-MA41 价格&库存

很抱歉,暂时无法提供与“E3NX-MA41”相匹配的价格&库存,您可以联系我们找货

免费人工找货
E3NX-MA41
  •  国内价格 香港价格
  • 1+4191.103581+537.59329
  • 5+3949.983855+506.66484
  • 10+3860.0258210+495.12591

库存:1