Temperature Sensor
E52
CSM_E52_DS_E_16_1
A Wide Variety of High-precision
Temperature Sensors
• New and improved E52 temperature sensor series.
Wide selection of sensors compatible with M3 screws
• Ideal for the thermal input devices of Temperature Controllers.
• Select from a wide variety of Temperature Sensors according
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
Refer to Safety Precautions for All Temperature
Controllers.
Ordering Information
■ List of Models
Classification
Generalpurpose
Models
Description
Model and appearance
Sheathed E52-P@AY
platinum
resistance E52-P@C-N
thermometer
E52-P@B-N
−196°C to
450°C
Pt100
Sheathed
thermocouple
0°C to 900°C K (CA)
J (IC)
3-conduc- B
tor system
Protective
tubing
material
Terminal
type
Exposed 5
lead wires
ASTM316L
Enclosed
terminals
Nongrounded
type
2 (0.75)
Enclosed
terminals
ASTM316L
Exposed 9 to
lead wires 12
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
E52-CA@B-N
E52-IC@B-N
SUS316
E52-CA1DY
E52-IC1DY
0°C to
1,400°C
R (PR)
0°C to 250°C Pt100
−50°C to
250°C
0°C to 400°C K (CA)
J (IC)
2 (0.25)
3-conduc- B
tor system
13
14
Enclosed
terminals
15
JIS ceramic Enclosed
JIS special terminals
ceramic
16
SUS316
Exposed 17
lead wires
SUS304
Nongrounded
type
2 (0.75)
Grounded
type
E52-CA6F-N
E52-IC6F-N
E52-CA6D-N
E52-IC6D-N
E52-CA10AE-N
E52-IC10AE-N
7
Exposed
terminals
E52-CA@C-N
E52-IC@C-N
E52-CA@ASY
E52-IC@ASY
6
SUS316
Exposed
terminals
Low-cost E52-P10AEY
platinum
resistance E52-P6DY
thermomE52-P6FY
eter
Page
SUS316
E52-CA@B-N
E52-IC@B-N
E52-PR@C-N
Low-cost
thermocouple
Class
Exposed
terminals
0°C to 450°C
E52-CA@AY
E52-IC@AY
Conductor type
−200°C to
450°C
Standard E52-P@C-N
platinum
resistance
thermometer
Standard
thermocouple
Low-cost
Models
TemperaElement
ture range
type
(See note 3.)
18
19
20
Nongrounded
type
Note: 1. Exclusive models are provided on the following page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
1
E52
Classification
Description
Model and appearance
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GVY
E52-IC2GVY
0°C to 350°C K (CA)
J (IC)
Crimping
terminals
E52-CA1GTY
E52-IC1GTY
0°C to 300°C
Conductor type
Class
Grounded 2 (0.75)
type
−50°C to
250°C
Used for
E52-P10GRY
room temperature
measurement
−50°C to
60°C
Double-el- E52-CA20AY-7
ement
model
0°C to 900°C K (CA)
Two nongrounded
types
E52-P20AY-7
−196°C to
250°C
Two 3-con- B
ductor
systems
E52-P20C-N-7
−200°C to
450°C
E52-P5AY-40
Corrosion- E52-P20AY-1
resistant
model
E52-CA20AY-1
Protective
tubing
material
SUS304
Terminal
type
Page
Exposed 21
lead wires
---
Used for
E52-P2GSY
measuring surface
temperatures
WaterE52-P10GPY
proof model
Thermistors
TemperaElement
ture range
type
(See note 3.)
Pt100
3-conduc- B
tor system
SUS304
22
Pt100
2 (0.75)
ASTM316L
25
Enclosed
terminals
0°C to 70°C
3-conductor system
SUS304
−50°C to
180°C
26
Exposed 22
lead wires
Fluororesin
tubing
23
SUS304
26
−80°C to
180°C
0°C to 180°C K (CA)
Nongrounded
type
Silicone- E52-CA1DY-40
covered
lead wires
0°C to 300°C
Grounded
type
E52-CA1GTY-14
0°C to 200°C
2 (0.75)
---
Explosion- E52-P@@C-N-6
proof model
---
Pt100
3-conduc- B
tor system
E52-CA@@C-N-6
---
K (CA)
Nongrounded
type
E52-THE5A
E52-THE6F
E52-THE6D
−50°C to
300°C
Thermistor
Element- 1
interchangeable
thermistor
ASTM316L
Enclosed
terminals
24
SUS304
Exposed 28
lead wires
2 (0.75)
Note: 1. General-purpose models and low-cost models are provided on the previous page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
2
E52
■ Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Accessory
Compression
Fitting
Temperature
range
600°C max.
Mounting example
Mounting with
Compression
Fitting
Page
29
Terminal box
Compression Fitting
PT screw
Welding
Loose Flange
400°C max.
Protective tubing
Mounting with
Loose Flange
Loose Flange
Mounting screw
Terminal box
Protective tubing
Note: The Compression Fitting is not
of airtight construction. Do not
use the Compression Fitting for
applications in which the
exposure of the sensing object
will cause problems.
Note: 1. Use the Loose Flange in
normal atmospheric
pressure. The Loose
Flange is not of airtight
construction.
2. Use the Loose Flange at
400°C max.
3. Do not apply the Loose
Flange to protective tubing
diameters other than the
applicable ones.
3
E52
General-purpose Models
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
E52-@@@ D=@@@M
1 2 3
4
5 6
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-@@AY
Diameter (D)
Length (L)
3.2
7 to 100
4.8
10 to 600
6.4
13 to 1,300
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
8: 8-mm dia. (Protective tubing construction: Sheathed)
E52-@@B-N and E52-@@C-N only
10: 10-mm dia. (Protective tubing construction: Standard)
E52-@@C-N only
5. Heat resistance
E52-@@B-N
Code
Diameter (D)
8
Length (L)
Diameter (D)
Vinyl-covered
NETU
0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Length (L)
3.2
12 to 100
4.8
15 to 600
6.4
18 to 1,300
8
21 to 100
10
26 to 100
Lead type
−20°C to 70°C
Sleeve: 0°C to 70°C
20 to 100
E52-@@C-N
Temperature range
---
Specify for E52-@@AY model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52@@AY only:
Range: 0.5, 1 to 100 m
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
B-N: Exposed terminals
C-N: Enclosed terminals
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AY D=4.8 NETU 10M
■ Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B
Sheath material
SUS316 (E52-P@AY)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter
3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type
3-conductor system
Temperature range
−200°C to 450°C (in dry air)
4
E52
Exposed-lead Models
E52-P@AY
Dimensions
Red (A)
Unit (mm)
Y-type crimp terminal for M3.5
Maker tube
Lead wire
SUS304 sleeve
d
White (B)
M
Black (B)
d
l
3.2 dia.
8
40
4.8 dia.
8
40
6.4 dia.
8
40
D
Sheath (SUS316)
D
L
Lead Wire
• Standard (−20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
• Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
• Lead Wire Length (M): 1, 2, 4, or 8 m
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 3.2 dia.
Models
Protective
tubing length
L (cm)
15
35
20
35
50
2
4
8
Standard
E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8
1M
2M
4M
8M
Heat resistive
E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8
1M
2M
4M
8M
Heat resistive
E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P50AY D=4.8
1M
E52-P50AY D=4.8
NETU 1M
Heat resistive
6.4 dia.
Lead wire length M (m)
1
Model
20
4.8 dia.
Lead wire
type
20
35
50
E52-P50AY D=4.8
2M
E52-P50AY D=4.8
NETU 2M
E52-P50AY D=4.8
4M
E52-P50AY D=4.8
NETU 4M
E52-P50AY D=4.8
8M
E52-P50AY D=4.8
NETU 8M
Standard
E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
5
E52
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
67
15
Socket (SUS304)
Chain
Sheath (ASTM316L)
D
66
Caulking
Terminal box
Cap
G3/8,
Packing internal
diameter 6.5 dia.
(See note 2.)
L-35
40
Use wiring terminals that fit M3 screws.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: 1. The terminals in the cap indicate polarity (A, B, b).
2. The length L is in centimeters, but “35” is 35 millimeters.
Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L − 35 = 350 − 35 = 315 mm.
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
Enclosed-terminal
Models
20
E52-P20C-N D=3.2
E52-P20C-N D=4.8
E52-P20C-N D=6.4
E52-P20C-N D=8
35
E52-P35C-N D=3.2
E52-P35C-N D=4.8
E52-P35C-N D=6.4
E52-P35C-N D=8
50
E52-P50C-N D=3.2
E52-P50C-N D=4.8
E52-P50C-N D=6.4
E52-P50C-N D=8
75
---
E52-P75C-N D=4.8
E52-P75C-N D=6.4
---
Exposed-terminal Models
E52-P@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Model Information
Sheath (ASTM316L)
42.5
15
Custom-made models are available on request. Refer to page 4 for
details
Terminal box
Socket (SUS304)
A
B
b
45
D
Caulking
17.6
3-M3
Terminal
type
(See note.)
L-40
Product label
Terminal box: The permissible temperature is 0°C to 100°C.
Exposedterminal
Models
Protective
Protective tubing diameter D (mm)
tubing length
8 dia.
L (cm)
Model
20
E52-P20B-N D=8
35
E52-P35B-N D=8
50
E52-P50B-N D=8
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm.
6
E52
■ Standard Platinum Resistance Thermometers
Refer to Model Number Legend on page 4 for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B (See note 2.)
Protective tubing material
SUS316
Conductor type
3-conductor system
Temperature range
0°C to 450°C (in dry air)
Note: 1. Use the sheathed platinum resistance thermometer if
condensation is likely to result.
2. Be sure that the thermometer is free of vibration or shock if
high temperatures are measured.
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
96
Terminal box
SUS316 protective tubing
Chain
D
86
Socket (SUS304)
5
Cap
(See note 1.)
G1/2,
Packing internal
diameter 9 dia.
L-50
53
Note: 1. The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (A, B, B).
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective tubing
length L (cm)
Protective tubing
diameter D (mm)
10 dia.
Model
Enclosed-terminal
Models
35
E52-P35C-N D=10
50
E52-P50C-N D=10
75
E52-P75C-N D=10
100
E52-P100C-N D=10
7
E52
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
E52-@@@ D=@@@M@
1 2 3
4
5 6
7
1. Element type
CA:K
IC: J
PR:R
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
4. Diameter
Specify the protective tubing material according to the table.
Code
Diameter Protective tubing
(D)
construction
Protective tubing
material
1
1 mm
Sheathed
ASTM316L
1.6
1.6 mm
Sheathed
ASTM316L
E52-@@AY (Exposed-lead Model)
3.2
3.2 mm
Sheathed
ASTM316L
Diameter (D)
4.8
4.8 mm
Sheathed
ASTM316L
2 to 200
6.4
6.4 mm
Sheathed
ASTM316L
3 to 500
8
8 mm
Sheathed
ASTM316L
3.2
5 to 2,000
10
10 mm
Standard
SUS316, SUS310S
4.8
8 to 2,300
12
12 mm
Standard
SUS316, SUS310S
10 to 1,200
15
15 mm
Standard
SUS316, SUS310S
12 to 1,000
22
22 mm
Standard
SUS316, SUS310S
17
17 mm
Standard
PT1, PT0
1
1.6
6.4
8
Length (L)
E52-@@B-N and E52-@@C-N (except E52-PR@C-N)
Diameter (D)
Length (L)
3.2
11 to 2,000
4.8
14 to 2,300
6.4
16 to 1,200
8.0
18 to 1,000
10
21 to 126
12
24 to 126
15
29 to 156
22
39 to 206
E52-PR@C-N
Diameter (D)
15
5. Heat resistance
Specify this item for the exposed-lead models only.
Code
Temperature range
Lead type
---
−20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU
0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with external shield of stainless
6. Lead length (M)
Specify the length in meters in the following range for the E52@@AY only.
Range: 1 to 100 m
7. Protective tubing material
Length (L)
Code
50, 75, 100
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
(element type: K, J)
B-N: Exposed terminals (element type: K, J)
C-N: Enclosed terminals (element type: K, J, R)
Protective tubing
material
Element type
---
ASTM316L
SUS310S
SUS310S
K, J
K, D = 10 to 22
PT1
JIS ceramic Cat.1
R
PT0
JIS special ceramic
R
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA42AY D=4.8 NETU 10M
Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2
E52-IC36C-N D=3.2
8
E52
■ Sheathed Thermocouples
Specifications
Permissible Temperature in Dry Air
Element type
D
K (CA), J(IC)
Class
JIS class 2 (0.75)
Thermal contact
Non-grounded type
Sheath material
CA: ASTM316L
Element wire
K (CA)
ASTM316L
IC: ASTM316L
J (IC)
ASTM316L
1 dia.
650°C
450°C
1.6 dia.
650°C
450°C
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AY
Dimensions
Y-type crimp terminal for M3.5
Red (+)
Lead wire (See note 1.)
Unit (mm)
SUS304 sleeve
(See note 2.)
Sheath (ASTM316L)
d
White (−)
M
d
l
1 dia.
8
55
1.6 dia.
8
55
3.2 dia.
8
55
1 dia.
650°C
55
1.6 dia.
650°C
55
3.2 dia.
750°C
55
4.8 dia.
800°C
6.4 dia.
800°C
8.0 dia.
900°C
D
D
L
Permissible Temperature in Dry Air
4.8 dia.
Note: 1. Lead Wire (Compensating Conductor)
• Standard (−20°C to 70°C):
6.4 dia.
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
8 dia.
thick) and external dimensions of 2.4 × 4.1.
• Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
• Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between −20°C and 70°C
for standard models and 0°C and 100°C for heat-resistive models.
8
11
11
D
Element wire
K (CA)
ASTM316L
K (CA) Model Information (E52-CA@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Lead wire type
Lead wire length M (m)
1
2
4
8
Model
Exposed-lead
Models
1 dia.
15
20
35
1.6 dia.
15
20
35
Standard
E52-CA15AY D=1 1M E52-CA15AY D=1 2M E52-CA15AY D=1 4M E52-CA15AY D=1 8M
Heat resistive
E52-CA15AY D=1
NETU 1M
E52-CA15AY D=1
NETU 2M
E52-CA15AY D=1
NETU 4M
E52-CA15AY D=1
NETU 8M
Standard
E52-CA20AY D=1 1M E52-CA20AY D=1 2M E52-CA20AY D=1 4M E52-CA20AY D=1 8M
Heat resistive
E52-CA20AY D=1
NETU 1M
E52-CA20AY D=1
NETU 2M
E52-CA20AY D=1
NETU 4M
E52-CA20AY D=1
NETU 8M
Standard
E52-CA35AY D=1 1M E52-CA35AY D=1 2M E52-CA35AY D=1 4M E52-CA35AY D=1 8M
Heat resistive
E52-CA35AY D=1
NETU 1M
E52-CA35AY D=1
NETU 2M
E52-CA35AY D=1
NETU 4M
E52-CA35AY D=1
NETU 8M
Standard
E52-CA15AY D=1.6
1M
E52-CA15AY D=1.6
2M
E52-CA15AY D=1.6
4M
E52-CA15AY D=1.6
8M
Heat resistive
E52-CA15AY D=1.6
NETU 1M
E52-CA15AY D=1.6
NETU 2M
E52-CA15AY D=1.6
NETU 4M
E52-CA15AY D=1.6
NETU 8M
Standard
E52-CA20AY D=1.6
1M
E52-CA20AY D=1.6
2M
E52-CA20AY D=1.6
4M
E52-CA20AY D=1.6
8M
Heat resistive
E52-CA20AY D=1.6
NETU 1M
E52-CA20AY D=1.6
NETU 2M
E52-CA20AY D=1.6
NETU 4M
E52-CA20AY D=1.6
NETU 8M
Standard
E52-CA35AY D=1.6
1M
E52-CA35AY D=1.6
2M
E52-CA35AY D=1.6
4M
E52-CA35AY D=1.6
8M
Heat resistive
E52-CA35AY D=1.6
NETU 1M
E52-CA35AY D=1.6
NETU 2M
E52-CA35AY D=1.6
NETU 4M
E52-CA35AY D=1.6
NETU 8M
9
E52
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Lead wire type
Lead wire length M (m)
1
2
4
8
Model
Exposed-lead
Models
3.2 dia.
15
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
Standard
E52-CA15AY D=3.2
1M
E52-CA15AY D=3.2
2M
E52-CA15AY D=3.2
4M
E52-CA15AY D=3.2
8M
Heat resistive
E52-CA15AY D=3.2
NETU 1M
E52-CA15AY D=3.2
NETU 2M
E52-CA15AY D=3.2
NETU 4M
E52-CA15AY D=3.2
NETU 8M
Standard
E52-CA20AY D=3.2
1M
E52-CA20AY D=3.2
2M
E52-CA20AY D=3.2
4M
E52-CA20AY D=3.2
8M
Heat resistive
E52-CA20AY D=3.2
NETU 1M
E52-CA20AY D=3.2
NETU 2M
E52-CA20AY D=3.2
NETU 4M
E52-CA20AY D=3.2
NETU 8M
Standard
E52-CA35AY D=3.2
1M
E52-CA35AY D=3.2
2M
E52-CA35AY D=3.2
4M
E52-CA35AY D=3.2
8M
Heat resistive
E52-CA35AY D=3.2
NETU 1M
E52-CA35AY D=3.2
NETU 2M
E52-CA35AY D=3.2
NETU 4M
E52-CA35AY D=3.2
NETU 8M
Standard
E52-CA50AY D=3.2
1M
E52-CA50AY D=3.2
2M
E52-CA50AY D=3.2
4M
E52-CA50AY D=3.2
8M
Heat resistive
E52-CA50AY D=3.2
NETU 1M
E52-CA50AY D=3.2
NETU 2M
E52-CA50AY D=3.2
NETU 4M
E52-CA50AY D=3.2
NETU 8M
Standard
E52-CA20AY D=4.8
1M
E52-CA20AY D=4.8
2M
E52-CA20AY D=4.8
4M
E52-CA20AY D=4.8
8M
Heat resistive
E52-CA20AY D=4.8
NETU 1M
E52-CA20AY D=4.8
NETU 2M
E52-CA20AY D=4.8
NETU 4M
E52-CA20AY D=4.8
NETU 8M
Standard
E52-CA35AY D=4.8
1M
E52-CA35AY D=4.8
2M
E52-CA35AY D=4.8
4M
E52-CA35AY D=4.8
8M
Heat resistive
E52-CA35AY D=4.8
NETU 1M
E52-CA35AY D=4.8
NETU 2M
E52-CA35AY D=4.8
NETU 4M
E52-CA35AY D=4.8
NETU 8M
Standard
E52-CA50AY D=4.8
1M
E52-CA50AY D=4.8
2M
E52-CA50AY D=4.8
4M
E52-CA50AY D=4.8
8M
Heat resistive
E52-CA50AY D=4.8
NETU 1M
E52-CA50AY D=4.8
NETU 2M
E52-CA50AY D=4.8
NETU 4M
E52-CA50AY D=4.8
NETU 8M
Standard
E52-CA20AY D=6.4
1M
E52-CA20AY D=6.4
2M
E52-CA20AY D=6.4
4M
E52-CA20AY D=6.4
8M
Heat resistive
E52-CA20AY D=6.4
NETU 1M
E52-CA20AY D=6.4
NETU 2M
E52-CA20AY D=6.4
NETU 4M
E52-CA20AY D=6.4
NETU 8M
Standard
E52-CA35AY D=6.4
1M
E52-CA35AY D=6.4
2M
E52-CA35AY D=6.4
4M
E52-CA35AY D=6.4
8M
Heat resistive
E52-CA35AY D=6.4
NETU 1M
E52-CA35AY D=6.4
NETU 2M
E52-CA35AY D=6.4
NETU 4M
E52-CA35AY D=6.4
NETU 8M
Standard
E52-CA50AY D=6.4
1M
E52-CA50AY D=6.4
2M
E52-CA50AY D=6.4
4M
E52-CA50AY D=6.4
8M
Heat resistive
E52-CA50AY D=6.4
NETU 1M
E52-CA50AY D=6.4
NETU 2M
E52-CA50AY D=6.4
NETU 4M
E52-CA50AY D=6.4
NETU 8M
Standard
E52-CA20AY D=8 1M E52-CA20AY D=8 2M E52-CA20AY D=8 4M E52-CA20AY D=8 8M
Heat resistive
E52-CA20AY D=8
NETU 1M
E52-CA20AY D=8
NETU 2M
E52-CA20AY D=8
NETU 4M
E52-CA20AY D=8
NETU 8M
Standard
E52-CA35AY D=8 1M E52-CA35AY D=8 2M E52-CA35AY D=8 4M E52-CA35AY D=8 8M
Heat resistive
E52-CA35AY D=8
NETU 1M
E52-CA35AY D=8
NETU 2M
E52-CA35AY D=8
NETU 4M
E52-CA35AY D=8
NETU 8M
Standard
E52-CA50AY D=8 1M E52-CA50AY D=8 2M E52-CA50AY D=8 4M E52-CA50AY D=8 8M
Heat resistive
E52-CA50AY D=8
NETU 1M
E52-CA50AY D=8
NETU 2M
E52-CA50AY D=8
NETU 4M
E52-CA50AY D=8
NETU 8M
10
E52
Exposed-lead Models
E52-IC@AY
Dimensions
Red (+)
Unit (mm)
Y-type crimp terminal for M3.5 SUS304 sleeve
(See note 2.) Sheath (ASTM316L)
Lead wire (See note 1.)
d
White (−)
M
d
l
1 dia.
8
55
1.6 dia.
8
55
3.2 dia.
8
55
1 dia.
450°C
450°C
D
D
L
Note: 1. Lead Wire (Compensating Conductor)
• Standard (−20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
• Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
• Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between −20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
Permissible Temperature in Dry Air
D
Element wire
J (IC)
ASTM316L
4.8 dia.
8
55
1.6 dia.
6.4 dia.
11
55
3.2 dia.
650°C
55
4.8 dia.
750°C
6.4 dia.
750°C
8.0 dia.
750°C
8 dia.
11
J (IC) Model Information (E52-IC@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 1 dia.
Models
Protective
tubing length
L (cm)
Lead wire length M (m)
1
2
4
Model
15
20
35
1.6 dia.
Lead wire
type
15
20
35
Standard
E52-IC15AY D=1 1M
E52-IC15AY D=1 2M
E52-IC15AY D=1 4M
Heat resistive
E52-IC15AY D=1 NETU
1M
E52-IC15AY D=1 NETU
2M
E52-IC15AY D=1 NETU
4M
Standard
E52-IC20AY D=1 1M
E52-IC20AY D=1 2M
E52-IC20AY D=1 4M
Heat resistive
E52-IC20AY D=1 NETU
1M
E52-IC20AY D=1 NETU
2M
E52-IC20AY D=1 NETU
4M
Standard
E52-IC35AY D=1 1M
E52-IC35AY D=1 2M
E52-IC35AY D=1 4M
Heat resistive
E52-IC35AY D=1 NETU
1M
E52-IC35AY D=1 NETU
2M
E52-IC35AY D=1 NETU
4M
Standard
E52-IC15AY D=1.6 1M
E52-IC15AY D=1.6 2M
E52-IC15AY D=1.6 4M
Heat resistive
E52-IC15AY D=1.6 NETU E52-IC15AY D=1.6 NETU E52-IC15AY D=1.6 NETU
1M
2M
4M
Standard
E52-IC20AY D=1.6 1M
Heat resistive
E52-IC20AY D=1.6 NETU E52-IC20AY D=1.6 NETU E52-IC20AY D=1.6 NETU
1M
2M
4M
E52-IC20AY D=1.6 2M
E52-IC35AY D=1.6 2M
E52-IC20AY D=1.6 4M
Standard
E52-IC35AY D=1.6 1M
Heat resistive
E52-IC35AY D=1.6 NETU E52-IC35AY D=1.6 NETU E52-IC35AY D=1.6 NETU
1M
2M
4M
E52-IC35AY D=1.6 4M
11
E52
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 3.2 dia.
Models
Protective
tubing length
L (cm)
15
35
50
20
35
50
6.4 dia.
20
35
50
8 dia.
Lead wire length M (m)
1
2
4
Model
20
4.8 dia.
Lead wire
type
20
35
50
Standard
E52-IC15AY D=3.2 1M
Heat resistive
E52-IC15AY D=3.2 NETU E52-IC15AY D=3.2 NETU E52-IC15AY D=3.2 NETU
1M
2M
4M
E52-IC15AY D=3.2 2M
E52-IC20AY D=3.2 2M
E52-IC15AY D=3.2 4M
Standard
E52-IC20AY D=3.2 1M
Heat resistive
E52-IC20AY D=3.2 NETU E52-IC20AY D=3.2 NETU E52-IC20AY D=3.2 NETU
1M
2M
4M
E52-IC35AY D=3.2 2M
E52-IC20AY D=3.2 4M
Standard
E52-IC35AY D=3.2 1M
Heat resistive
E52-IC35AY D=3.2 NETU E52-IC35AY D=3.2 NETU E52-IC35AY D=3.2 NETU
1M
2M
4M
E52-IC50AY D=3.2 2M
E52-IC35AY D=3.2 4M
Standard
E52-IC50AY D=3.2 1M
Heat resistive
E52-IC50AY D=3.2 NETU E52-IC50AY D=3.2 NETU E52-IC50AY D=3.2 NETU
1M
2M
4M
Standard
E52-IC20AY D=4.8 1M
Heat resistive
E52-IC20AY D=4.8 NETU E52-IC20AY D=4.8 NETU E52-IC20AY D=4.8 NETU
1M
2M
4M
E52-IC20AY D=4.8 2M
E52-IC35AY D=4.8 2M
E52-IC50AY D=3.2 4M
E52-IC20AY D=4.8 4M
Standard
E52-IC35AY D=4.8 1M
Heat resistive
E52-IC35AY D=4.8 NETU E52-IC35AY D=4.8 NETU E52-IC35AY D=4.8 NETU
1M
2M
4M
E52-IC50AY D=4.8 2M
E52-IC35AY D=4.8 4M
Standard
E52-IC50AY D=4.8 1M
Heat resistive
E52-IC50AY D=4.8 NETU E52-IC50AY D=4.8 NETU E52-IC50AY D=4.8 NETU
1M
2M
4M
Standard
E52-IC20AY D=6.4 1M
Heat resistive
E52-IC20AY D=6.4 NETU E52-IC20AY D=6.4 NETU E52-IC20AY D=6.4 NETU
1M
2M
4M
E52-IC20AY D=6.4 2M
E52-IC35AY D=6.4 2M
E52-IC50AY D=4.8 4M
E52-IC20AY D=6.4 4M
Standard
E52-IC35AY D=6.4 1M
Heat resistive
E52-IC35AY D=6.4 NETU E52-IC35AY D=6.4 NETU E52-IC35AY D=6.4 NETU
1M
2M
4M
E52-IC50AY D=6.4 2M
E52-IC35AY D=6.4 4M
Standard
E52-IC50AY D=6.4 1M
Heat resistive
E52-IC50AY D=6.4 NETU E52-IC50AY D=6.4 NETU E52-IC50AY D=6.4 NETU
1M
2M
4M
E52-IC50AY D=6.4 4M
Standard
E52-IC20AY D=8 1M
E52-IC20AY D=8 2M
E52-IC20AY D=8 4M
Heat resistive
E52-IC20AY D=8 NETU
1M
E52-IC20AY D=8 NETU
2M
E52-IC20AY D=8 NETU
4M
Standard
E52-IC35AY D=8 1M
E52-IC35AY D=8 2M
E52-IC35AY D=8 4M
Heat resistive
E52-IC35AY D=8 NETU
1M
E52-IC35AY D=8 NETU
2M
E52-IC35AY D=8 NETU
4M
Standard
E52-IC50AY D=8 1M
E52-IC50AY D=8 2M
E52-IC50AY D=8 4M
Heat resistive
E52-IC50AY D=8 NETU
1M
E52-IC50AY D=8 NETU
2M
E52-IC50AY D=8 NETU
4M
12
E52
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Permissible Temperature in Dry Air
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
38.5
Sheath
(ASTM316L)
Socket (SUS304)
D
−
Caulking
(See note)
15
16
Element wire
K (CA)
ASTM316L
Terminal box
+
44
D
J (IC)
ASTM316L
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
L-40
Two, M3
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L − 40 = 500 − 40 = 460 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
K (CA)
Exposed-terminal Models
J (IC)
Exposed-terminal Models
20
E52-CA20B-N D=3.2
E52-CA20B-N D=4.8
E52-CA20B-N D=6.4
---
35
E52-CA35B-N D=3.2
E52-CA35B-N D=4.8
E52-CA35B-N D=6.4
E52-CA35B-N D=8
50
E52-CA50B-N D=3.2
E52-CA50B-N D=4.8
E52-CA50B-N D=6.4
E52-CA50B-N D=8
75
---
E52-CA75B-N D=4.8
E52-CA75B-N D=6.4
E52-CA75B-N D=8
20
E52-IC20B-N D=3.2
E52-IC20B-N D=4.8
E52-IC20B-N D=6.4
---
35
E52-IC35B-N D=3.2
E52-IC35B-N D=4.8
E52-IC35B-N D=6.4
E52-IC35B-N D=8
50
E52-IC50B-N D=3.2
E52-IC50B-N D=4.8
E52-IC50B-N D=6.4
E52-IC50B-N D=8
75
---
E52-IC75B-N D=4.8
E52-IC75B-N D=6.4
E52-IC75B-N D=8
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
67
Socket (SUS304)
Sheath
(ASTM316L)
Permissible Temperature in Dry Air
D
Element wire
K (CA)
ASTM316L
Chain
D
66
Caulking
Terminal box
(See note)
G3/8,
Packing internal
diameter 6.5 dia.
40
L-40
Use wiring terminals that fit M3 screws.
J (IC)
ASTM316L
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or −).
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
K (CA)
J (IC)
Enclosed-terminal Models
Enclosed-terminal Models
20
E52-CA20C-N D=3.2
E52-CA20C-N D=4.8
E52-CA20C-N D=6.4
---
35
E52-CA35C-N D=3.2
E52-CA35C-N D=4.8
E52-CA35C-N D=6.4
E52-CA35C-N D=8
50
E52-CA50C-N D=3.2
E52-CA50C-N D=4.8
E52-CA50C-N D=6.4
E52-CA50C-N D=8
75
---
E52-CA75C-N D=4.8
E52-CA75C-N D=6.4
E52-CA75C-N D=8
20
E52-IC20C-N D=3.2
E52-IC20C-N D=4.8
E52-IC20C-N D=6.4
---
35
E52-IC35C-N D=3.2
E52-IC35C-N D=4.8
E52-IC35C-N D=6.4
E52-IC35C-N D=8
50
E52-IC50C-N D=3.2
E52-IC50C-N D=4.8
E52-IC50C-N D=6.4
E52-IC50C-N D=8
75
---
E52-IC75C-N D=4.8
E52-IC75C-N D=6.4
E52-IC75C-N D=8
13
E52
■ Standard Thermocouples
Specifications
Permissible Temperature in Dry Air (See note.)
D
Element wire
K (CA), J(IC), R
Class
K (CA), J (IC) JIS class 2 (0.75)
Protective tubing material
J (IC) SUS316
R, JIS class 2 (0.25)
10 dia.
750°C
450°C
K (CA) SUS316
12 dia.
850°C
500°C
J (IC)
15 dia.
850°C
550°C
22 dia.
900°C
600°C
SUS316
R (See JIS ceramic cat. 1 (PT1)
note.) JIS special ceramic (PT0)
Thermal contact
Element wire
K (CA) SUS316
Note: For details on the permissible temperature, refer to Technical
Guide for Temperature Sensors.
Non-grounded type
Note: Specify PT1 or PT0 if the element is R.
D
Element wire
R
15 dia.
0°C to 1,400°C
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
49.5
Terminal box
Socket (SUS304)
SUS316 protective tubing
+
70
D
−
5
(See note)
25
L-50
Two, M4
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm.
Permissible Temperature in Dry Air
D
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
750°C
450°C
12 dia.
850°C
500°C
15 dia.
850°C
550°C
22 dia.
900°C
600°C
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia.
12 dia.
15 dia.
22 dia.
Model
K (CA)
J (IC)
Exposed-terminal Models
Exposed-terminal Models
35
E52-CA35B-N D=10
E52-CA35B-N D=12
E52-CA35B-N D=15
---
50
E52-CA50B-N D=10
E52-CA50B-N D=12
E52-CA50B-N D=15
E52-CA50B-N D=22
75
E52-CA75B-N D=10
E52-CA75B-N D=12
E52-CA75B-N D=15
E52-CA75B-N D=22
100
E52-CA100B-N D=10
E52-CA100B-N D=12
E52-CA100B-N D=15
E52-CA100B-N D=22
35
E52-IC35B-N D=10
E52-IC35B-N D=12
E52-IC35B-N D=15
---
50
E52-IC50B-N D=10
E52-IC50B-N D=12
E52-IC50B-N D=15
E52-IC50B-N D=22
75
E52-IC75B-N D=10
E52-IC75B-N D=12
E52-IC75B-N D=15
E52-IC75B-N D=22
100
E52-IC100B-N D=10
E52-IC100B-N D=12
E52-IC100B-N D=15
E52-IC100B-N D=22
14
E52
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
96
Terminal box
SUS316 protective tubing
Chain
86
D
Socket (SUS304)
40 dia.
5
(See note)
53
L-50
1
G /2,
Packing internal diameter 9 dia.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L − 50 = 500 − 50 = 450 mm.
Permissible Temperature in Dry Air
D
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
0 to 750°C
0 to 450°C
12 dia.
0 to 850°C
0 to 500°C
15 dia.
0 to 850°C
0 to 550°C
22 dia.
0 to 900°C
0 to 600°C
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or −).
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Element type Terminal type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia.
12 dia.
15 dia.
22 dia.
Model
K (CA)
J (IC)
Enclosed-terminal Models
Enclosed-terminal Models
35
E52-CA35C-N D=10
E52-CA35C-N D=12
E52-CA35C-N D=15
---
50
E52-CA50C-N D=10
E52-CA50C-N D=12
E52-CA50C-N D=15
E52-CA50C-N D=22
75
E52-CA75C-N D=10
E52-CA75C-N D=12
E52-CA75C-N D=15
E52-CA75C-N D=22
100
E52-CA100C-N D=10
E52-CA100C-N D=12
E52-CA100C-N D=15 E52-CA100C-N D=22
35
E52-IC35C-N D=10
E52-IC35C-N D=12
E52-IC35C-N D=15
50
E52-IC50C-N D=10
E52-IC50C-N D=12
E52-IC50C-N D=15
--E52-IC50C-N D=22
75
E52-IC75C-N D=10
E52-IC75C-N D=12
E52-IC75C-N D=15
---
100
E52-IC100C-N D=10
E52-IC100C-N D=12
E52-IC100C-N D=15
---
15
E52
Enclosed-terminal Models (High-temperature Use)
E52-PR@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
96
Terminal box
SUS304
Porcelain protective tube
When L = 500
Swing of protective tube: 6 mm or less
Chain
Permissible
Temperature in Dry Air
D
Element wire
R
22 dia.
86
15 dia.
Lock nut (SUS304)
Filled with heat resistant cement
40 dia.
5
(See note)
100
53
L-150
G1/2,
Packing internal diameter 9 dia.
Use wiring terminals that fit M4 screws.
15 dia. 0°C to 1,400°C
Terminal box: The
permissible temperature
is 0°C to 90°C.
Note: The terminals in
the cap indicate
polarity (+ or −).
Note: The length L is in centimeters, but “150” is 150 millimeters.
Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L − 150 = 750 − 150 = 600 mm.
Model Information
Element
type
Terminal
type
Protective
tubing
length L
(cm)
Protective tubing
diameter D (mm)
15 dia.
Model
R (See
note 1.)
Enclosed-ter- 50
minal Models 75
100
R (See
note 2.)
Enclosed-ter- 50
minal Models 75
100
Standard
E52-PR50C-N D=15 PT1
E52-PR75C-N D=15 PT1
E52-PR100C-N D=15 PT1
E52-PR50C-N D=15 PT0
E52-PR75C-N D=15 PT0
E52-PR100C-N D=15 PT0
Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
1,500°C (See note.)
Note 2:
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
1,700°C (See note.)
Note: The permissible temperature given for the protective tubing is
higher than 1,400°C, but the permissible temperature of the
thermocouple element wire is only 1,400°C. Therefore, the
protective tubing of the E52-PR@C-N can withstand high
temperatures momentarily to the levels given in the table as
exceptions, but the element wire will deteriorate quickly if the
thermocouple is used regularly at temperatures that exceed the
permissible temperature for the element wire.
16
E52
Low-cost Models
■ Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Specifications
E52-P6DY
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
−50°C to 150°C
Tapered pipe thread
Argon arc welding SUS304
R1/8
Silicone tubing
SUS304 (t0.25)
Caulking
4 dia.
Fluororesin-covered wire
with 1.0 outer dia. each
(PFA) 7/0.18
Red (A)
Black (B)
14
30
10 6
65
15
Black (B)
Y-type crimp
terminal for M3.5
M
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6DY 1M
2
E52-P6DY 2M
4
E52-P6DY 4M
Exposed-lead Models with Flange
Specifications
E52-P6FY
Element wire
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
−50°C to 150°C
Flange
120°
SUS304
Three, 3.5 dia.
120°
SUS304 (t0.25) 4 dia.
Fluororesin-covered wire
with 1.0 outer dia. each
Silicone tubing (PFA) 7/0.18
Caulking
Red (A)
White (B)
1
20 dia.
30 dia.
65
Silver
soldering Y-type crimp
30
terminal for M3.5
M
15
White (B)
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6FY 1M
2
E52-P6FY 2M
4
E52-P6FY 4M
Exposed-lead Models
Specifications
E52-P10AEY
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
Temperature
range
0°C to 250°C
Lead wire
−50°C to 180°C
Product label
Y-type crimp
terminal for M3.5
M
100
Fluororesin-covered wire with 1.0 outer dia.
each (PFA) 7/0.2
(30)
White (B)
B
B
A
3.2 dia.
Caulking Silicone
shrinkable tubing
Shrinkable tube (black)
White (B)
Red (A)
Marker tube
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m)
Model
1
E52-P10AEY 1M
2
E52-P10AEY 2M
4
E52-P10AEY 4M
17
E52
■ Low-cost Thermocouples
Exposed-lead Models with Spring
E52-CA@ASY, E52-IC@ASY
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
0.65 mm (single wire)
Class
Class 2 (0.75)
L±3
SUS304 (t0.4)
Protective tubing
material
SUS304
Thermal contact
Non-grounded type
Temperature range
0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
0°C to 180°C
32
12 dia.
150
Marker tube(White)
Lead Wire(Red)
M
80
(+)
+
4.8 dia.
Note: The sleeve resists temperatures ranging
between 0°C and 100°C.
Sleeve
Brass-nickel Closely wound
plating
spring coil
−
(−)
Y-type crimp
terminal for M3.5
Marker tube(White)
Lead Wire
(White)
Fully glass-wool-covered
compensating cable with Color code
four 0.65-dia. conductors (K: Blue, J: Yellow)
and external dimensions
of approx. 5.1 × 3.0
L: Protective tubing length
M: Lead wire length
Note: The protective tubing is of pipe construction, which must not be bent.
Protective tubing length (mm)
Lead wire length (m)
Element type: K (CA)
Element type: J (IC)
Model
65
100
150
200
1
E52-CA6ASY 1M
E52-IC6ASY 1M
2
E52-CA6ASY 2M
E52-IC6ASY 2M
4
E52-CA6ASY 4M
E52-IC6ASY 4M
1
E52-CA10ASY 1M
E52-IC10ASY 1M
2
E52-CA10ASY 2M
E52-IC10ASY 2M
4
E52-CA10ASY 4M
E52-IC10ASY 4M
1
E52-CA15ASY 1M
E52-IC15ASY 1M
2
E52-CA15ASY 2M
E52-IC15ASY 2M
4
E52-CA15ASY 4M
E52-IC15ASY 4M
1
E52-CA20ASY 1M
E52-IC20ASY 1M
2
E52-CA20ASY 2M
E52-IC20ASY 2M
4
E52-CA20ASY 4M
E52-IC20ASY 4M
18
E52
Exposed-lead Models with Screw
E52-CA1DY, E52-IC1DY
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
0.65 mm (single wire)
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Grounded type
Temperature range
0.65-dia.
2.8
thermocouple
element
B 3.8 dia.
0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
0°C to 180°C
Terminal shape
Y-type crimp terminal
for M3.5
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8,
or W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of the
thermocouple is touching the sensing
object.
Installation Example
Movable ring
(brass)
10
A
C
M
Color tubing
Brass (K: Blue,
J: Yellow)
80
0.65-dia.
black wire
Movable ring
Brass
Cut after silver
soldering
Red (+)
White (−)
Color code
5 dia.
(K: Blue,
SUS304
Crimp terminal for M3.5
J: Yellow)
screw
(W1/4) Enamel-bonded
copper wire
Fully glass-wool-covered with external
copper shield and external dimensions of
approx. 3.1 × 2.0
Internal Construction (E52-CA1DY)
Closely wound
enamel-bonded coil.
M6
Lead wire
length (m)
Screw
W1/4
M6
M8
A (mm)
4.3
4
5.3
B (mm)
11.5
11.5
15
C (mm)
3.8
3.8
3.8
Brass pipe
Screw
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
End
1
Shielded
glass-wool lead
wire
Workpiece
Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40).
Refer to page 26 for details.
Protective tubing length (mm)
Lead wire length (m)
Element type: K (CA)
Element type: J (IC)
Model
M6 screw
M8 screw
W1/4 screw
1
E52-CA1DY M6 1M
E52-IC1DY M6 1M
2
E52-CA1DY M6 2M
E52-IC1DY M6 2M
4
E52-CA1DY M6 4M
E52-IC1DY M6 4M
1
E52-CA1DY M8 1M
E52-IC1DY M8 1M
2
E52-CA1DY M8 2M
E52-IC1DY M8 2M
4
E52-CA1DY M8 4M
E52-IC1DY M8 4M
1
E52-CA1DY W1/4 1M
E52-IC1DY W1/4 1M
2
E52-CA1DY W1/4 2M
E52-IC1DY W1/4 2M
4
E52-CA1DY W1/4 4M
E52-IC1DY W1/4 4M
19
E52
Exposed-lead Models with Flange
Specifications
E52-CA6F-N, E52-IC6F-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Lead wire
0°
12
4 dia.
Fluororesin-covered thermocouple wire with external
Silicon dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Peel processed
shrinkable tube
Caulking
SUS304
SUS304
Red (+)
0°
Temperature
range
12
Thermal contact Grounded type
Silver soldering
Three, 3.5 dia.
White (−)
0°C to 350°C: K
(CA)
0°C to 350°C: J
(IC)
1
20 dia.
65±2
15
Shrinkable
tube
30
10
80±10
M
Lead wire length (M): 1, 2, or 4 m
30 dia.
0°C to 150°C
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA6F-N 1M
E52-IC6F-N 1M
2
E52-CA6F-N 2M
E52-IC6F-N 2M
4
E52-CA6F-N 4M
E52-IC6F-N 4M
Exposed-lead Models with Screws
Specifications
E52-CA6D-N, E52-IC6D-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Tapered pipe
thread
14
SUS304
R 1/8
4 dia.
Fluororesin-covered thermocouple wire with external
dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Silicon
shrinkable tube
Peel processed
Caulking
Red (+)
Thermal contact Grounded type
Temperature
range
Lead wire
White (−)
0°C to 350°C: K
(CA)
0°C to 350°C: J
(IC)
0°C to 150°C
6
65±2
15
Shrinkable
tube
30
80±10
10
M
Lead wire length (M): 1, 2, or 4 m
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA6D-N 1M
E52-IC6D-N 1M
2
E52-CA6D-N 2M
E52-IC6D-N 2M
4
E52-CA6D-N 4M
E52-IC6D-N 4M
Exposed-lead Models
Specifications
E52-CA10AE-N, E52-IC10AE-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Fluororesin-covered thermocouple wire with external
dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Peel processed
Protective tubing
3.2 dia.
Thermal contact Non-grounded
type
Temperature
range
Lead wire
0°C to 350°C: K
(CA)
0°C to 200°C: J
(IC)
0°C to 180°C
Red (+)
White (−)
Caulking
SUS304
Shrinkable
tube
M
100
Note: 1.
2.
3.
4.
10
80
The thermocouple is a single wire from the tip to the terminal.
Lead wire length M: 1, 2, or 4 m
The protective tubing is of pipe construction, which must not be bent.
The thermocouple cannot be mounted using a PT@ Compression Fitting.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA10AE-N 1M
E52-IC10AE-N 1M
2
E52-CA10AE-N 2M
E52-IC10AE-N 2M
4
E52-CA10AE-N 4M
E52-IC10AE-N 4M
20
E52
Exclusive Models
■ Thermocouples
Thermocouples for Molding Machines
Specifications
E52-CA2GVY, E52-IC2GVY
Element type
K (CA), J (IC)
Dimensions
Element
diameter
1.0 mm (single
wire)
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Glass-covered stainless steel shielded
thermocouple wire
Y-type crimp
12.5 dia.
Spring
terminal for M3.5
15
dia.
14 dia.
Spring retainer Marker tube
6.8 dia.
SUS304
4.1 dia.
Bayonet
−
Temperature
range
0°C to 350°C
Lead wire
0°C to 180°C
4.8 dia. 25±2
15
5 dia.
Red (+)
+
Thermal contact Grounded type
Adapter (provided)
(See note.)
22
Shrinkable tube
100±10
85±10
8 dia. 12 dia.
White (−)
10
10 15
Note: The Adapter is included
with the Thermocouple.
If it is lost or damaged,
you can order a
replacement with the
following model number.
Adapter: Y92F-S1
M
Lead wire length (M): 1 or 2 m
Lead wire
length (m)
1
R/
8
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA2GVY 1M
E52-IC2GVY 1M
2
E52-CA2GVY 2M
E52-IC2GVY 2M
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTY, E52-IC1GTY
Element type
K (CA), J (IC)
Dimensions
Element
diameter
0.65 mm (single
wire)
M4, round crimp terminal
8
Silicone tubing
Class
Class 2 (0.75)
Glass-wool-braided shield with maximum
external dimensions of 2.6 × 4.0
White/red stripe (+)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire
0°C to 150°C
Terminal shape
Y-type crimp
terminal for M3.5
Note: The E52-CA1GTY is also
available with double elements.
Refer to page 26 for details.
4.3 dia.
White stripe (−)
Color code
(K: Blue, J: Yellow)
6 dia. max.
15
80
Y-type crimp
terminal for M3.5
M
Lead wire length (M): 1 or 2 m
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA1GTY 1M
E52-IC1GTY 1M
2
E52-CA1GTY 2M
E52-IC1GTY 2M
■ Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
Specifications
E52-P2GSY
Element type
Pt100
Dimensions
Class
Class B
Protective
tubing material
SUS304
With brass-nickelplated bracket
Conductor type
3-conductor
system
Temperature
range
−50°C to 250°C
Lead wire
−50°C to 150°C
Brass-nickel-plated bracket
Four, 3.2 dia.
3
Silicone-covered 3-conductor cable
with thirty 0.08-dia. conductors (0.15-mm thick)
and approx. 3.9 dia.
Product label
6-dia.
Marker tube
Caulking
A
5
20±1
5
B
B
1.5
4.50
14±0.6
6
Silicon shrinkable tube
20±0.5
28±1
30
M
Red (A)
White (B)
White (B)
30
Name plate A
80
Lead wire length (M): 1 or 2 m
Lead wire length (m)
Model
1
E52-P2GSY 1M
2
E52-P2GSY 2M
21
E52
Platinum Resistance Thermometers for Room Temperature Measurement
Specifications
E52-P10GRY
Element type
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
3-conductor system
Dimensions
70±1 dia.
42±1 dia.
Temperature range −50°C to 60°C
Lead wire
Two, 8 dia.
Aluminum alloy AC3A
6.1 dia. 27 dia.
−20°C to 60°C
69.5±1
6.1-outer-dia.
vinyl-covered 3-conductor
cable (twenty 0.18-dia.
conductors, 0.5 mm thick)
22.2 dia. BS (Ni plated)
8.0 dia. SUS304
Enclosed resistance
thermometer
56
(30)
A
B
B
4.8 dia.
97
Lead wire length (m)
2
Red (A)
White (B)
Black (B)
Marker tube
Shrinkable
tube
95
100
Y-type crimp
terminal for M3.5
85±10
2,000
Model
E52-P10GRY 2M
Waterproof Platinum Resistance Thermometers
Specifications
E52-P10GPY
Element wire
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
Dimensions
6.1-outer-dia. vinyl-covered
3-conductor cable (twelve 0.18-dia.
conductors, 0.5 mm thick)
SUS304 protective tubing
3-conductor system
−25°C to 60°C
Resistive pressure 10 kg/cm max.
2
Marker tube
Name plate
6.1 dia.
A
B
B
Temperature range 0°C to 70°C (underwater)
−20°C to 70°C (in the air)
Lead wire
20 dia.
7 dia.
Y-type crimp
terminal for M3.5
98
100
Shrinkable
tube
12
62
5
Red (A)
White (B)
White (B)
(30)
85±10
M
Lead wire length (M): 2 or 4 m
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AY-40 if waterproof lead wires are required for use underwater.
Refer to page 23 for details.
Lead wire length (m)
Model
2
E52-P10GPY 2M
4
E52-P10GPY 4M
22
E52
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing
■ Thermocouples
Exposed-lead Models
Specifications
E52-CA20AY-1
Element type
K (CA)
Class
Class 2 (0.75)
Protective tubing
material
ASTM316L with
Fluororesin-covered
(FEP) tube
Thermal contact
Non-grounded type
Temperature range
0°C to 180°C
Lead wire
Vinyl-covered: −20°C
to 70°C
Dimensions
Fixed with adhesive tape and
silicone heat-shrinking tube
Product label
Y-type crimp
terminal for M3.5
Red (+)
White (−)
Sleeve
Compensating
conductor
Sheath
d
D
+
−
Filled with epoxy resin
90±10
FEP-covered tubing
Caulking
200
2,000
Model
Protective
tubing
diameter
E52-CA20AY-1 D=4.6 2M D = 4.6
Sleeve diameter Covering
(mm)
thickness
Sleeve length
(mm)
(mm)
d=8
l = 55
E52-CA20AY-1 D=6 2M D = 6.0
E52-CA20AY-1 D=8 2M D = 8.0
0.7
Lead wire
length (m)
2
0.6
d = 11
l = 55
0.8
■ Platinum Measurement
Exposed-lead Models
Specifications
E52-P20AY-1
Element type
Pt100
Class
Class B
Protective tubing
material
SUS316 with
Fluororesin-covered
(FEP) tube
Conductor type
3-conductor system
Temperature range
−80°C to 180°C
Lead wire
Dimensions
Y-type crimp
terminal for M3.5
Lead wires
Marker tube
Red
White
White
Fixed with adhesive tape and
silicone heat-shrinking tube
Filled with epoxy resin
Sheath
Sleeve
(9.5 dia.)
D
A
B
B
Shrinkable tube
85±10
Vinyl-covered: −20°C
to 70°C
Model
d
FEP-covered tubing
35
2,000
205
Protective
tubing
diameter
Sleeve
diameter
(mm)
Coating
thickness
(mm)
E52-P20AY-1 D=4.6 2M D = 4.6
d=8
0.7
E52-P20AY-1 D=6 2M
D = 6.0
d=8
0.6
E52-P20AY-1 D=8 2M
D = 8.0
d=8
0.8
Lead wire
length (m)
2
FEP-molded Models (Completely Waterproof)
Specifications
E52-P5AY-40
Element type
Pt100
Class
Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type
3-conductor system
Temperature range
−50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover): −50°C to 180°C
Y-type crimp terminal for M3.5
Dimensions
Marker tube
Element FEP mold
Fused (completely waterproof)
6 dia.
PFA-covered wire 0.18/7
Product label
3.5 dia.
A
B
B
65
30±5
Red (A)
White (B)
White (B)
80
90±10
M
Model
Lead wire length (m)
E52-P5AY-40 2M
2
E52-P5AY-40 4M
4
E52-P5AY-40 6M
6
E52-P5AY-40 8M
8
23
E52
Pressure-resistant Explosion-proof (IICT6) Models
■ Thermocouples
Enclosed-terminal Models
E52-CA@@C-N-6
L
Dimensions
131.5
L2
L1
Socket (SUS304)
10
15 dia.
6.4 dia.
113
Sheath
(ASTM316L)
SUS304
O-ring
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Class 3 (Level 1.5) at -40°C
and under
Protective tubing material
113
64.6
L2 section: ASTM316L
L1 section: SUS304
70
Explosion- Construction
Pressure-resistant
proof
explosion-proof structure
specifica- Explosion-protected IICT6
tions
class and ignitability
G1/2
Explosion-proof
temperature range
−20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
E52-CA20C-N-6 D=6.4 L2=150
20
D = 6.4
150
Conduit thread
G1/2
E52-CA35C-N-6 D=6.4 L2=300
35
D = 6.4
300
Installation method
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
E52-CA50C-N-6 D=6.4 L2=450
50
D = 6.4
450
E52-CA75C-N-6 D=6.4 L2=700
75
D = 6.4
700
Model
Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
■ Platinum Resistance Thermometers for Surface Temperature Measurement
Enclosed-terminal Models
E52-P@@C-N-6
L
Dimensions
131.5
L1
L2
10
Socket (SUS304)
15 dia.
6.4 dia.
113
Specifications
Sheath
(ASTM316L)
SUS304
Element type
Pt100
Class
Class B
Protective tubing material
L2 section: ASTM316L
L1 section: SUS304
O-ring
Explosion- Construction
Pressure-resistant
proof
explosion-proof structure
specifica- Explosion-protected IICT6
tions
class and ignitability
64.6
G1/2
70
Explosion-proof
temperature range
−20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread
G1/2
E52-P20C-N-6 D=6.4 L2=150
20
D = 6.4
150
Installation method
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
E52-P35C-N-6 D=6.4 L2=300
35
D = 6.4
300
E52-P50C-N-6 D=6.4 L2=450
50
D = 6.4
450
E52-P75C-N-6 D=6.4 L2=700
75
D = 6.4
700
Model
Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
24
E52
Double-element Models
■ Thermocouple
Exposed-lead Models
Specifications
E52-CA20AY-7
Element type
K (CA)
Dimensions
Class
Class 2 (0.75)
Y-type crimp
terminal for M3.5
Protective tubing ASTM316L
material
(with sheath)
Thermal contact
Non-grounded type
Temperature
range
0°C to permissible
temperature limit
Lead wire
Vinyl-covered: −20°C
to 70°C
Product label
Marker tube
Red (+)
Compensating
conductor
Sleeve Sheath
(ASTM316L)
+
−
White (−)
d
D
Red (+)
+
−
White (−)
80
90±10
30
2,000
55
200
Permissible Temperature in Dry Air
D
Element wire
K (CA)
ASTM316L
3.2 dia.
750°C
4.8 dia.
800°C
6.4 dia.
800°C
8.0 dia.
900°C
Model
Protective
tubing
diameter
Sleeve
diameter
(mm)
Permissible Lead wire
Temperature length (m)
(°C)
E52-CA20AY-7 D=3.2 2M D = 3.2
d = 11
750
2
E52-CA20AY-7 D=4.8 2M D = 4.8
d = 11
800
2
E52-CA20AY-7 D=6.4 2M D = 6.4
d = 11
800
2
E52-CA20AY-7 D=8.0 2M D = 8.0
d = 11
900
2
■ Platinum Resistance Thermometers
Exposed-lead Models
Specifications
E52-P20AY-7
Element type
Pt100
Dimensions
Class
Class B
Y-type crimp
terminal for M3.5
Protective tubing ASTM316L
material
(with sheath)
Red (A)
Conductor type
3-conductor system
White (B)
Temperature
range
−200°C to 450°C
White (B)
Lead wire
Vinyl-covered: −20°C
to 70°C
Red (A)
White (B)
Wire marks (1, 2)
Marker tube Indicated by pair
Lead wire with
all-vinyl coating
Product label
A
B
B
11 dia.
6.5 dia.
1
A
B
B
Sleeve (SUS304)
Sheath
(ASTM316L)
Caulking
D
2
Filled with epoxy resin
White (B)
Silicon shrinkable tube
80
90±10
Model
30
55
M
Protective
tubing diameter
200±6
Lead wire
length (m)
E52-P20AY-7 D=4.8 2M
D = 4.8
2
E52-P20AY-7 D=6.4 2M
D = 6.4
2
25
E52
Enclosed-terminal Models
Specifications
E52-P20C-N-7
Element type
Pt100
Class
Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type
3-conductor system
Temperature range
−200°C to 450°C
Dimensions
96
Terminal for terminal connection
Size: M4
Terminal box
82 dia.
Sheath (ASTM316L)
Socket (SUS304)
D
86
Caulking
15
(See note)
L-50
53
Model
Protective tubing
Protective
length L (cm)
tubing diameter
E52-P20C-N-7 D=4.8
20
D = 4.8
E52-P20C-N-7 D=6.4
20
D = 6.4
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L − 50 = 200 − 50 = 150 mm.
Silicone-covered Lead Wires Models
■ Thermocouples
Exposed-lead Models with Screws
Specifications
E52-CA1DY-40
Element type
K (CA)
Class
Class 2 (0.75)
Screw material
SUS304
Thermal contact
Grounded type
Temperature range
0°C to 300°C
Lead wire
Silicone-covered (0.1/30): 0°C to
150°C
Terminal shape
Y-type crimp terminal for M3.5
Dimensions
1
2.8
10
4.2
M
13
80
Silicone
covering
80
Red (+)
11
White (−)
8 dia. Caulking SUS304
Silicone
spring with
Thermocovering Y-type crimp
6.5 outer dia.
couple
terminal for 3.5
SUS304 screw and 5.2
element
Silicone
inside dia.
wire
shrinkable tubing
3.8 dia.
Movable ring
Note: Refer to the installation example for the E52-CA1DY.
Model
Screw pitch
Lead wire
length (m)
E52-CA1DY-40 M6 1M
M6
1
E52-CA1DY-40 M6 2M
M6
2
E52-CA1DY-40 M6 4M
M6
4
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTY-14
Element type
K (CA)
Class
Class 2 (0.75)
Thermal contact
Grounded type
Temperature range
0°C to 200°C
Lead wire
Silicone-covered : 0°C to 150°C
Terminal shape
Y-type crimp terminal for M3.5
Dimensions
Silicone-covered
M4, round,
compensating cable with
crimp terminal twenty 0.18-dia.
conductors and external
8
dimensions of 5.5 dia.
Color tubing
Blue CA (K)
Red (+)
White (−)
4.3 dia.
15
30
80
M
Y-type crimp
terminal for M3.5
Lead wire length (M): 1 or 2 m
Model
Lead wire length (m)
E52-CA1GTY-14 1M
1
E52-CA1GTY-14 2M
2
26
E52
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Temperature
range
Color code
Nominal resistance
Thermistor
constant
−50°C to 50°C
Blue
6 kΩ (0°C)
3390K
0°C to 100°C
Black
6 kΩ (0°C)
3390K
50°C to 150°C
Red
30 kΩ (0°C)
3450K
100°C to 200°C
Yellow
0.55 kΩ (200°C)
4300K
150°C to 300°C
Green
4 kΩ (200°C)
5133K
Lead wire
A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with
0.86 outer dia. each
Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors
and external dimensions of 2.5 × 1.55
Specifications
Item
Coupling method
E52-THE@@
Element interchangeable thermistor
Class
JIS class 1
Protective tubing material
SUS304
Time constant
8 to 15 s in still water
Dissipation factor
2.4 to 2.8 mW/°C in still air
Lead wire heat resistive
temperature
180°C
Error
Detectable temperature
Error
−50°C to 100°C
±1°C max.
100°C to 350°C
±1% max. of detectable temperature
Permissible Temperature
Detectable temperature
Operating temperature
−50°C to 50°C
100°C
0°C to 100°C
150°C
50°C to 150°C
200°C
100°C to 200°C
250°C
150°C to 300°C
350°C
Note: Models with non-standard lead wire length and protective
tubing length are available on request.
This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.
27
E52
Exposed-lead Models
E52-THE5A
Dimensions
SUS304 t0.25
Temperature range
Lead wires
(See note.)
Caulking
Color code
4 dia.
15
50
50 10
1,030
Model
−50°C to 50°C
E52-THE5A −50-50°C 1M
0°C to 100°C
E52-THE5A 0-100°C 1M
50°C to 150°C
E52-THE5A 50-150°C 1M
100°C to 200°C
E52-THE5A 100-200°C 1M
150°C to 300°C
E52-THE5A 150-300°C 1M
Note: The lead wires have no polarity
Exposed-lead Models with Screws
E52-THE6D
Temperature range
Dimensions
Tapered pipe thread
SUS304
Lead wires
R1/8
(See note.)
SUS304 t0.25
Color code
4 dia.
Argon arc welding
15
10 6
14
65
15
Model
−50°C to 50°C
E52-THE6D −50-50°C 1M
0°C to 100°C
E52-THE6D 0-100°C 1M
50°C to 150°C
E52-THE6D 50-150°C 1M
100°C to 200°C
E52-THE6D 100-200°C 1M
150°C to 300°C
E52-THE6D 150-300°C 1M
50 10
1,000
Note: The lead wires have no polarity
Exposed-lead Models with Flange
E52-THE6F
Temperature range
Dimensions
Three, 3.5 dia.
120°
120°
SUS304
SUS304 t0.25
Silver
soldering
Lead wires
(See note.)
Color code
4 dia.
15
1
20 dia.
30 dia.
65
15
Model
−50°C to 50°C
E52-THE6F −50-50°C 1M
0°C to 100°C
E52-THE6F 0-100°C 1M
50°C to 150°C
E52-THE6F 50-150°C 1M
100°C to 200°C
E52-THE6F 100-200°C 1M
150°C to 300°C
E52-THE6F 150-300°C 1M
50 10
1,000
Note: The lead wires have no polarity
Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. If waterproof performance is required, be sure that
the lead cable joint is of waterproof construction as well.
2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the
temperature range.
28
E52
Accessories
Compression Fittings
Model Information
Model
Screw of part
Applicable
a
protective tubing
diameter
PT 1/8 D=1.0
R 1/8
Dimension
b
1.0 dia.
PT 1/8 D=1.6
1.6 dia.
PT 1/8 D=3.2
3.2 dia.
PT 1/8 D=4.8
c
d
Flat diameter
Part c
Part b
5
13
10
14
14
5
15
12
17
14
4.8 dia.
PT 1/4 D=3.2
R 1/4
3.2 dia.
PT 1/4 D=4.8
4.8 dia.
PT 1/4 D=6.4
6.4 dia.
PT 3/8 D=8
R 3/8
8 dia.
5
19
15
21
17
PT 1/2 D=10
R 1/2
10 dia.
8
23.5
19.5
26
21
M 12 D=4.8
M 12
4.8 dia.
5
15
12
17
14
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the
sensing object will cause problems.
The compression fitting is a screw that adjusts and secures the
insertion length of Temperature Sensors with the above protective
tubing diameters.
The material of the Compression Fitting is SUS304 with internal
fixing beads made of brass.
a
Protective tubing dia.
D
Sensor side
Head side
d
c
b
Tighten using the retaining screw to
secure to the protective tubing.
Material
Main body
SUS304
Lock bead
Brass
Retaining screw
SUS304
Source: JIS B 0203 (Unit: mm)
NomiT.P.I.
Outer
nal
(No. of diamethread threads ter: d
size
/inch)
Effective
diameter: d2
Root
diameter: d1
Standard
diameter
position a
(from
pipe
end)
Minimum
effective
screw
length:
f
PT 1/8
28
9.728
9.147
8.566
3.97
±0.91
2.5
PT 1/4
19
13.157
12.301
11.445
6.01
±1.34
3.7
PT 3/8
19
16.662
15.806
14.950
6.35
±1.34
3.7
PT 1/2
14
20.955
19.793
18.631
8.16
±1.81
5.0
a
f
Tapered thread
d d2
d1
Standard dia.
29
E52
Loose Flanges
Model Information
Applicable protective
tubing diameter
MF-1
Model
3.2 dia.
MF-1 D=3.2
4.8 dia.
MF-1 D=4.8
6.4 dia.
MF-1 D=6.4
8 dia.
MF-1 D=8
10 dia.
MF-2 D=10
12 dia.
MF-2 D=12
15 dia.
MF-2 D=15
22 dia.
MF-2 D=22
Note: 1. Use the Loose Flange in atmospheric pressure. The Loose
Flange is not of airtight construction.
2. Use the Loose Flange at 400°C maximum.
3. Do not apply the Loose Flange to protective tubing
diameters other than the applicable ones.
MF-2
120°
120°
Three, 5 dia.
Three, 6.5 dia.
36
54 dia.
21 dia.
D dia.
M4
31 dia.
D dia.
5
14
24
23 dia.
45 dia.
M6
6.6
35 dia.
70 dia.
Material: Aluminum
30
E52
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected
to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between
−20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available.
Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Thermocouple
R
Heat
resistance
Exterior
Model
(Length)
1m
2m
4m
8m
Standard
Fully vinyl-covered (waterproof)
WPRG-N 1M
WPRG-N 2M
WPRG-N 4M
WPRG-N 8M
Heat resistive
Fully glass-wool-covered
WPRH-N 1M
WPRH-N 2M
WPRH-N 4M
WPRH-N 8M
Fully glass-wool-covered with external shield WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M
of stainless steel
K (CA)
Standard
Fully vinyl-covered (waterproof)
WCAG-N 1M
WCAG-N 2M
WCAG-N 4M
WCAG-N 8M
Heat resistive
Fully glass-wool-covered
WCAH-N 1M
WCAH-N 2M
WCAH-N 4M
WCAH-N 8M
Fully glass-wool-covered with external shield WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M
of stainless steel
J (IC)
Silicone-covered (See note 2.)
WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M
Standard
Vinyl covered (waterproof)
WICG-N 1M
WICG-N 2M
WICG-N 4M
WICG-N 8M
Heat resistive
Fully glass-wool-covered
WICH-N 1M
WICH-N 2M
WICH-N 4M
WICH-N 8M
Fully glass-wool-covered with external shield WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M
of stainless steel
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above
100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.
2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.
Specifications (JIS C1610-1995)
Model
WPRG-N
Type of
thermocouple
R
WPRH-N
Use
Code
(See note.)
K (CA)
RCA-2-G
Fully vinyl-covered (waterproof) 7/0.3
0 to 90
±30
RCB-2-H
Fully glass-wool-covered
0 to 150
±60
±100
7/0.32
Exterior
color
Black
Standard
KCC-2-G
Fully vinyl-covered (waterproof) 7/0.3
0 to 90
Heat resistive
KCB-2-H
Fully glass-wool-covered
7/0.32
0 to 150
30/0.1
−20 to 150
±100
±140
Blue
Fully glass-wool-covered with
external shield of stainless steel
WCAG-40
WICH6-N
Error (°C)
Heat resistive
WCAH6-N
WICG-N
Operating
temperature
range (°C)
Fully glass-wool-covered with
external shield of stainless steel
WCAH-N
WICH-N
Number of
wires/wire
diameter
Standard
WPRH6-N
WCAG-N
Exterior
J (IC)
Heat resistive
KX-2-G
for moving parts
Silicone-covered
Standard
JX-2-G
Fully vinyl-covered (waterproof) 7/0.3
−20 to 90
Heat resistive
JX-2-H
Fully glass-wool-covered
0 to 150
7/0.32
Yellow
Fully glass-wool-covered with
external shield of stainless steel
Note: Symbols conform to JIS standards.
For code having duplicate exterior, check the application and check in our models.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
31
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.