E5ANHAA2HBM500AC100240 数据手册
E5_N-H/E5_N-HT
Advanced and Multi-Loop controllers
Universal compact digital
process controllers
The E5_N-H series of process controllers take the proven concept of the general
purpose E5_N series to a process level. Main features of the E5_N-H series are
universal inputs, process outputs and options such as transfer output, remote setpoint and setvalue programmer.
•
•
•
•
•
Control mode: ON/OFF or 2-PID, Valve control on EN-H/AN-H
Control output: relay, voltage (pulse), SSR, linear current and voltage
Power supply: 100/240 VAC or 24 VDC/VAC
Easy PC connection for parameter cloning, setting and tuning
Clear and intuitive set-up and operation
Ordering information
Type
Input
Output
Fixed option
Alarms
Order code
On-panel
Universal
TC/Pt/mV
mA/V
Relay output
–
3 software E5CN-HR2M-500 AC100-240
alarms
E5CN-HQ2M-500 AC100-240
2 SUB
E5CN-HC2M-500 AC100-240
outputs
E5CN-HV2M-500 AC100-240
48x48 mm model (includes supply voltage indication)
Voltage (pulse)
Current output
Linear voltage output
Relay output
Voltage (pulse)
Current output
SV programmer
(8 programs of
32 segments)
Linear voltage output
Note: -
E5CN-HTQ2MD-500 AC/DC24
E5CN-HTC2M-500 AC100-240
E5CN-HTC2MD-500 AC/DC24
E5CN-HTV2M-500 AC100-240
E5CN-HTV2MD-500 AC/DC24
Order code
E53-CNBN2
Control output 2
Voltage (for driving SSR)
E53-CNQBN2
Event inputs
Heater burnout/SSR failure/
Heater overcurrent detection
Event inputs
Communications
RS-232C
Transfer output
E53-CN01N2
Communications
RS-232C
E53-CNQ01N2
Communications
RS-232C
Heater burnout/SSR failure/
Heater overcurrent detection
Communications
RS-485
Communications
RS-485
E53-CNHBN2
E53-CNBFN2
Control output 2
Voltage (for driving SSR)
E53-CNH01N2
E53-CN03N2
Control output 2
Voltage (for driving SSR)
E53-CNQO3N2
Communications
RS-485
Heater burnout/SSR failure/
Heater overcurrent detection
Communications
RS-485
3-phase heater burnout/SSR failure/ E53-CNHH03N2
Heater overcurrent detection
Control output 2
Voltage (for driving SSR)
490
Transfer output
E5CN-HV2MD-500 AC/DC24
E5CN-HTR2MD-500 AC/DC24
E5CN-H option boards
(One slot available in each instrument)
Event inputs
E5CN-HC2MD-500 AC/DC24
E5CN-HTQ2M-500 AC100-240
Accessories
Event inputs
E5CN-HQ2MD-500 AC/DC24
E5CN-HTR2M-500 AC100-240
Output and Alarm Relays: 3 A/250 VAC, electrical life: 100,000 operations
Output voltage (pulse): 12 V, 21 mA (ie. to drive solid state relays)
Linear current: 0(4) to 20 mA
Linear voltage output: 0 to 10 V
Option
E5CN-HR2MD-500 AC/DC24
E53-CNH03N2
E53-CNQFN2
Control output 2
Voltage (for driving SSR)
Heater burnout/SSR failure/
Heater overcurrent detection
E53-CNQHN2
Control output 2
Voltage (for driving SSR)
3-phase heater burnout/SSR failure/ E53-CNQHHN2
Heater overcurrent detection
E5_N-H/E5_N-HT
Advanced and Multi-Loop controllers
Control method
Auxiliary output
Control output 1/2 Heater burnout
Basic
2 alarm relays
none fitted, 2 slots
48x96 mm model
E5AN-HAA2HBM-500 AC100-240
E5EN-HAA2HBM-500 AC100-240
none fitted, 2 slots
E5AN-HAA2HBMD-500 AC/DC24
E5EN-HAA2HBMD-500 AC/DC24
2 SSR output fitted
E5AN-HSS2HBM-500 AC100-240
E5EN-HSS2HBM-500 AC100-240
2 SSR output fitted
E5AN-HSS2HBMD-500 AC/DC24
E5EN-HSS2HBMD-500 AC/DC24
E5AN-HAA2HHBFM-500 AC100-240
E5EN-HAA2HHBFM-500 AC100-240
E5AN-HAA2HHBFMD-500 AC/DC24
E5EN-HAA2HHBFMD-500 AC/DC24
2 SSR output fitted
E5AN-HSS2HHBFM-500 AC100-240
E5EN-HSS2HHBFM-500 AC100-240
2 SSR output fitted
E5AN-HSS2HHBFMD-500 AC/DC24
E5EN-HSS2HHBFMD-500 AC/DC24
none fitted, 2 slots
E5AN-HAA3BFM-500 AC100-240
E5EN-HAA3BFM-500 AC100-240
none fitted, 2 slots
E5AN-HAA3BFMD-500 AC/DC24
E5EN-HAA3BFMD-500 AC/DC24
2 SSR output fitted
E5AN-HSS3BFM-500 AC100-240
E5EN-HSS3BFM-500 AC100-240
2 SSR output fitted
E5AN-HSS3BFMD-500 AC/DC24
E5EN-HSS3BFMD-500 AC/DC24
2 relay output fitted
E5AN-HPRR2BM-500 AC100-240
E5EN-HPRR2BM-500 AC100-240
E5AN-HPRR2BMD-500 AC/DC24
E5EN-HPRR2BMD-500 AC/DC24
E5AN-HPRR2BFM-500 AC100-240
E5EN-HPRR2BFM-500 AC100-240
E5AN-HPRR2BFMD-500 AC/DC24
E5EN-HPRR2BFMD-500 AC/DC24
E5AN-HTAA2HBM-500
E5EN-HTAA2HBM-500 AC100-240
E5AN-HTAA2HBMD-500
E5EN-HTAA2HBMD-500 AC/DC24
E5AN-HTAA2HHBFM-500
E5EN-HTAA2HHBFM-500
E5AN-HTAA2HHBFMD-500
E5EN-HTAA2HHBFMD-500
E5AN-HTAA3BFM-500
E5EN-HTAA3BFM-500
E5AN-HTAA3BFMD-500
E5EN-HTAA3BFMD-500
E5AN-HTPRR2BM-500
E5EN-HTPRR2BM-500
E5AN-HTPRR2BMD-500
E5EN-HTPRR2BMD-500
E5AN-HTPRR2BFM-500
E5EN-HTPRR2BFM-500
E5AN-HTPRR2BFMD-500
E5EN-HTPRR2BFMD-500
1-phase
3-phase
none fitted, 2 slots
Valve controller
2 alarm relays
4 to 20 mA
output
4 to 20 mA
output
SV programmer
(8 programs of
32 segments
2 alarm relays
none fitted, 2 slots
1-phase
3-phase
4 to 20 mA
output
3 alarm relays
SV programmer and 2 alarm relays
valve controller
Order code (includes supply voltage indication)
96x96 mm model
none fitted, 2 slots
3 alarm relays
Transfer output
2 relay output fitted
4 to 20 mA
output
Specifications E5CN-H/EN-H/AN-H
E5AN-H/EN-H output option boards
Supply voltage
100 to 240 VAC 50/60 Hz or 24 VAC, 50/60Hz; 24 VDC
Sensor input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W or PL II
(2 slots available in E5_N-HAA__-500 models:
SS models have 2 fixed SSR output modules)
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V or 0 to 10 V
Control mode
ON/OFF, 2-PID and valve (PRR)
Accuracy
Thermocouple: (± 0.1% of indicated value or ±1°C, whichever
is greater) ± digit max. *1
Platinum resistance thermometer: (± 0.1% of indicated value
or ± 0.5°C, whichever is greater) ± 1 digit max.
Analogue input: ± 0.1% FS ± 1 digit max.
Auto-tuning
yes, 40% and 100% MV output limit selection. When using
Heat/Cool: automatic cool gain adjustment
Self-tuning
yes
RS-232C/RS-422/RS-485
optional, CompowayF or Modbus selectable
Event input
Optional (Standard 2 event input in EN-H/AN-H)
QLP port (USB connection PC) yes
Ambient temperature
-10 to 55°C
IP Rating front panel
IP66
Sampling period
60 ms
Option
Order code
Relay
E53-RN
Voltage (pulse) PNP 12 VDC
E53-QN
Voltage (pulse) NPN 12 VDC
E53-Q3
Voltage (pulse) PNP 24 VDC
E53-Q4
Linear 4 to 20 mA
E53-C3N
Linear 0 to 20 mA
E53-C3DN
Linear 0 to 10 V
E53-V34N
Linear 0 to 5 V
E53-V35N
E5AN-H/EN-H option boards
(one slot available in each instrument)
Option
Order code
RS-232C communications (CompoWay/F/Modbus)
E53-EN01
RS-422 communications (CompoWay/F/Modbus)
E53-EN02
RS-485 communications (CompoWay/F/Modbus)
E53-EN03
event input
E53-AKB
21
Platinum resistance thermometer: Pt100 or JPt100
Temperature controllers
Note: - All E5EN-H/AN-H have 2 event inputs
- All E5EN-H/AN-H have Remote Setpoint 4 to 20 mA input
E5AN-H/EN-H series optional tools
Option
Order code
USB PC based configuration cable
E58-CIFQ1
PC based configuration and tuning software
CX-Thermo
EST2-2C-MV4
491
E5ANHAA2HBM500AC100240 价格&库存
很抱歉,暂时无法提供与“E5ANHAA2HBM500AC100240”相匹配的价格&库存,您可以联系我们找货
免费人工找货