E5CC-TRX3A5M-003

E5CC-TRX3A5M-003

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CONTROL TEMP/PROCESS 100-240V

  • 数据手册
  • 价格&库存
E5CC-TRX3A5M-003 数据手册
New Product Digital Temperature Controller E5□C/E5□C-T The E5C Series Temperature Controller provides a wide lineup of models to meet a variety of applications. These controllers are easy to setup and operate, have unique performance capabilities and offer excellent visibility. Digital Temperature Controllers: E5□C Series 1/32 DIN Panel Mount 48 × 24 mm 1/16 DIN Panel Mount 48 × 48 mm 1/8 DIN Panel Mount 48 × 96 mm 1/4 DIN Panel Mount 96 × 96 mm DIN 22.5 mm wide Controllers That Mount to DIN Track Models with Screw Terminal Blocks/ Models with Screwless Clamp Terminal Blocks E5GC page 2 Models with Screw Terminal Blocks E5CC page 18 Models with Push-In Plus Terminal Blocks E5CC-B page 18 Plug-in Models E5CC-U page 18 Models with Screw Terminal Blocks E5EC page 40 Models with Push-In Plus Terminal Blocks E5EC-B page 40 Models with Screw Terminal Blocks E5AC page 40 Models with Screw Terminal Blocks E5DC page 58 Models with Push-In Plus Terminal Blocks E5DC-B page 58 Programmable Digital Temperature Controllers: E5□C-T Series 1/16 DIN Panel Mount 48 × 48 mm Models with Screw Terminal Blocks E5CC-T page 78 1/8 DIN Panel Mount 48 × 96 mm Models with Screw Terminal Blocks E5EC-T page 96 1/4 DIN Panel Mount 96 × 96 mm Models with Screw Terminal Blocks E5AC-T page 96 1 Digital Temperature Controller E5GC (48  24 mm) Easy operation and high performance in a compact 1/32 DIN Panel Mount body • A compact body of 48  24  90 mm (W H D) that is ideal for small equipment, laboratory instruments, and others. • White PV display with a height of 10.5 mm for high visibility even with the compact body. • Removable terminal block to simplify maintenance. Select from screw terminal blocks or screwless clamp terminal blocks for the wiring method. • High-speed sampling at 50 ms. • Easy connections to a PLC with programless communications. • Set up the Controller without wiring the power supply by connecting to the computer with a Communications Conversion Cable (sold separately). Setup is easy with the CX-Thermo (sold separately). * * CSA conformance 48  24 mm Models with Screw Terminal Blocks E5GC- 6 □ 48  24 mm Models with Screwless Clamp Terminal Blocks E5GC- C □ Refer to your OMRON website for the most recent information on applicable safety standards. Refer to Safety Precautions on 122. Main I/O Functions Sensor Input Universal input • Thermocouple • Pt • Analog current/voltage E5GC Dual displays: PV/SV Control Output 1 • Relay output • Voltage output (for driving SSR) • Linear current output Indication Accuracy • Thermocouple input: ±0.3% of PV • Pt input: ±0.2% of PV • Analog input: ±0.2% of FS Sampling Period • 50 ms Event Inputs • None •1 •2 Serial Communications • None • RS-485 4-digit displays • PF (shift) Key • Temperature status display • Simple programming • Independent heating and cooling PID control • Changed parameter display • Display brightness setting • Simple transfer output (only on models with liner current outputs) • Work Bit Message Auxiliary Outputs • None •1 •2 This datasheet is provided as a guideline for selecting products. Be sure to refer to the following manuals for application precautions and other information required for operation before attempting to use the product. E5□C Digital Temperature Controllers User’s Manual (Cat. No. H174) E5□C Digital Temperature Controllers Communications Manual (Cat. No. H175) 2 E5GC Model Number Legend and Standard Models Model Number Legend E5GC-@@ @ @ @ M-@@@ (Example: E5GC-RX1A6M-015) −− − − − − −−− A B C D E F Model A B Control No. of outputs 1 auxiliary and 2 outputs C Power supply voltage D E F Terminal type Input type Options Meaning 48 × 24 mm E5GC Control output 1 Relay output Voltage output (for driving SSR) Linear current output RX QX *1 CX *2 0 1 2 A D 6 C M *3 *3, *4 *5 000 015 016 023 024 Control output 2 None None None None 1 2 100 to 240 VAC 24 VAC/DC Screw terminal blocks (with cover) Screwless clamp terminal blocks *6 Universal input HB alarm and HS alarm Communications Event inputs --------RS-485 ------1 1 --------2 *1. The control output can be used as a simple transfer output. *2. Only option 000 can be selected if an auxiliary output is zero. *3. Option 016 and 023 can be selected only if two auxiliary outputs are selected. *4. Option with HB and HS alarms (023) cannot be selected if a linear current output is selected for the control output. *5. Option 024 can be selected only if one auxiliary output is selected. *6. The specifications are different for Temperature Controllers with Push-In Plus terminal blocks. Refer to Precautions when Wiring on page 131. Heating and Cooling Control Using Heating and Cooling Control A Control Output Assignment An auxiliary output is used as the cooling control output. B Control If PID control is used, you can set PID control separately for heating and cooling. This allows you to handle control systems with different heating and cooling response characteristics. 3 E5GC Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Communications Conversion Cable Model E58-CIFQ2-E Note: Always use this product together with the E58-CIFQ2. This Cable is used to connect to the bottom-panel Setup Tool port. Current Transformers (CTs) Hole diameter 5.8 mm 5.8 mm 12.0 mm 12.0 mm Model E54-CT1 E54-CT1L* E54-CT3 E54-CT3L* *Lead wires are included with these CTs. If UL certification is required, use these CTs. Mounting Adapter Model Y92F-53 (2pcs) Note: This Mounting Adapter is provided with the Digital Temperature Controller. 4 Waterproof Packing Model Y92S-P12 Note: This Waterproof Packing is provided with the Digital Temperature Controller. Draw-out Jig Model Y92F-55 CX-Thermo Support Software Model EST2-2C-MV4 Note: CX-Thermo version 4.62 or higher is required for the E5GC. For the system requirements for the CX-Thermo, refer to information on the EST2-2C-MV4 on the OMRON website (www.ia.omron.com). Terminal Covers (for E5GC-@6) Model E53-COV27 Note: This Terminal Covers is provided with the Digital Temperature Controller. E5GC Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Linear current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Setting method Indication method Multi SP Bank switching Other functions Ambient operating temperature Ambient operating humidity Storage temperature Altitude Recommended fuse Installation environment * There are up to four event inputs. A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC 85 to 110% of rated supply voltage 5.9 VA max. at 100 to 240 VAC, and 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N/THB-N.) ON/OFF control or 2-PID control (with auto-tuning) SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value) Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000 1 or 2 (depends on model) SPST-NO relay outputs, 250 VAC, 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) 1 or 2 (depends on model) Contact input ON: 1 kΩ max., OFF: 100 kΩ min. Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max. Current flow: approx. 7 mA per contact Digital setting using front panel keys 11-segment digital displays and individual indicators Character height: PV: 10.5 mm, SV: 5.0 mm Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications. * None Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting (with no condensation or icing) 25 to 85% −25 to 65°C (with no condensation or icing) 2,000 m max. T2A, 250 VAC, time-lag, low-breaking capacity Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1) 5 E5GC Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B C/W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 1600 1500 Temperature range (°C) 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.0 400 400 400.0 400 400.0 260 300 200 100.0 100 Set value 90 100 0.0 -100 -200 100.0 -200 -199.9 0 1 0.0 -199.9 2 3 -20.0 -100 -20.0 6 7 8 -200 4 5 0 0 16 17 0 0 0 0 0 0 19 20 21 22 23 24 -100 -200 -199.9 -200 9 10 11 -200 -199.9 -200 12 13 14 15 18 Shaded settings are the default settings. The applicable standards for the input types are as follows: K, J, T, E, N, R, S, B: JIS C 1602-2015, IEC 60584-1 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 C/W: W5Re/W26Re, JIS C 1602-2015, ASTM E988-1990 JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 60751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) Analog input Input type Input specification Setting range Set value 6 Current Voltage 4 to 20 mA 0 to 20 mA 1 to 5 V 0 to 5 V Usable in the following ranges by scaling: -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999 25 26 27 28 0 to 10 V 29 E5GC Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.) Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1. Alarm output operation Description of function When alarm value X When alarm value X is positive is negative 0 Alarm function OFF Output OFF No alarm Set the upward deviation in the set point for the alarm upper L H limit (H) and the lower deviation in the set point for the alarm ON * 2 1 Upper- and lower-limit *1 OFF PV lower limit (L). The alarm is ON when the PV is outside this SP deviation range. Set the upward deviation in the set point by setting the alarm X X 2 ON ON Upper-limit value (X). The alarm is ON when the PV is higher than the OFF PV OFF PV (default) SP SP SP by the deviation or more. Set the downward deviation in the set point by setting the X X ON ON 3 Lower-limit alarm value (X). The alarm is ON when the PV is lower than OFF PV OFF PV SP SP the SP by the deviation or more. Set the upward deviation in the set point for the alarm upper L H Upper- and lower-limit limit (H) and the lower deviation in the set point for the alarm ON *3 4 OFF PV range *1 lower limit (L). The alarm is ON when the PV is inside this SP deviation range. Set value 5 6 7 8 9 10 11 Alarm type Upper- and lower-limit with ON OFF standby sequence *1 *5 Upper-limit with standby ON OFF sequence L Lower-limit with standby sequence ON OFF X Absolute-value upperlimit ON OFF Absolute-value lower-limit ON OFF Absolute-value upperlimit with standby sequence ON OFF Absolute-value lower-limit with standby sequence ON OFF 12 13 LBA (alarm 1 type only) PV change rate alarm 14 SP absolute-value upper-limit alarm ON OFF SP absolute-value lower-limit alarm ON OFF 15 H X SP SP PV ON OFF PV ON OFF PV ON OFF PV ON OFF PV ON OFF PV ON OFF X 0 X 0 X 0 X 0 ON OFF 16 X 0 PV A standby sequence is added to the upper-limit alarm (2). *6 PV A standby sequence is added to the lower-limit alarm (3). *6 X SP X 0 PV X 0 PV X 0 PV X 0 PV ON OFF SP ON OFF X 0 The alarm will turn ON if the process value is smaller than the alarm value (X) regardless of the set point. A standby sequence is added to the absolute-value upperlimit alarm (8). *6 A standby sequence is added to the absolute-value lowerlimit alarm (9). *6 X 0 SP X 0 SP This alarm type turns ON the alarm when the set point (SP) is higher than the alarm value (X). This alarm type turns ON the alarm when the set point (SP) is lower than the alarm value (X). Standard Control X MV 0 The alarm will turn ON if the process value is larger than the alarm value (X) regardless of the set point. *7 *8 SP ON OFF X 0 MV X MV 0 Standard Control ON OFF 17 SP This alarm type turns ON the alarm when the manipulated Heating/Cooling Heating/Cooling variable (MV) is higher than the alarm value (X). Control (Heating MV) Control (Heating MV) ON OFF MV absolute-value lower-limit alarm *9 X - Standard Control MV absolute-value upper-limit alarm *9 A standby sequence is added to the upper- and lower-limit alarm (1). *6 *4 PV SP Standard Control X MV 0 Always ON ON OFF X 0 MV This alarm type turns ON the alarm when the manipulated Heating/Cooling Heating/Cooling variable (MV) is lower than the alarm value (X). Control (Cooling MV) Control (Cooling MV) ON OFF X 0 MV Always ON 7 E5GC *1. With set values 1, 4, and 5, the upper- and lower-limit values can be set independently for each alarm type, and are expressed as “L” and “H.” *2. Set value: 1, Upper- and lower-limit alarm Case 3 (Always OFF) Case 2 Case 1 H0, L
E5CC-TRX3A5M-003 价格&库存

很抱歉,暂时无法提供与“E5CC-TRX3A5M-003”相匹配的价格&库存,您可以联系我们找货

免费人工找货