New Product Digital Temperature Controllers E5@Z 1/16, 1/8, and 1/4 DIN Temperature Controllers Join the Best-selling E5@Z Series • Models available with either temperature inputs or analog inputs. • A wide range of functions, such as a loop break alarm (LBA), manual output, and transfer output. • Easy-to-read 11-segment display. • Faster sampling at 250 ms. • Setting Tool port provided as a standard feature for easy connection to personal computers. • New protocol called Modbus is installed in the models with communications. E5@Z Series Digital Position-proportional Controller E5CZ E5EZ 1/16 DIN 1/8 DIN E5AZ E5EZ-PRR 1/4 DIN 1/8 DIN Contents Digital Temperature Controllers E5CZ/E5CZ-U ................................. 2 E5AZ/E5EZ ..................................... 14 E5EZ-PRR.................................................... 37 Common to Updated E5@Z Controllers • Operation...................................................... • Precautions .................................................. E5EZ-PRR 26 33 • Operation...................................................... • Precautions .................................................. 43 59 1 Digital Temperature Controllers E5CZ/E5CZ-U (48 × 48 mm) This Best-selling General-purpose 48×48-mm Temperature Controller Is Now Even Better. • Controllers now available with analog inputs. • Faster sampling at 250 ms. • Transfer output provided for easy output to recorders. • Models available with a loop break alarm (LBA) and heater short alarm (HS alarm). • Easy setting with 11-segment displays. • Setting protection indicator informs operator when protection is enabled. • Manual output provided. • New protocol called Modbus is installed in the models with communications. • USB-Serial conversion cable is available. 48 × 48 mm E5CZ 48 × 48 mm E5CZ-U Note: Refer to page 30 for information on changes in comparison to previous models. Note: Refer to Precautions on page 33. Main I/O Functions Event Inputs • None • Two Sensor Inputs • Universal thermocouple/Pt inputs (Models with temperature inputs) • Analog current/voltage inputs (Models with analog inputs) Indication Accuracy E5CZ • Thermocouple input: ±0.5% of PV • Pt input: ±0.5% of PV • Analog input: ±0.5% FS E5CZ-U • Thermocouple input: ±1% of PV • Pt input: ±0.5% of PV E5CZ 2-level Display: PV and SV Alarm Outputs • Two 4-digit Display • Auto/manual switching • Models also available with RS-485 communications Control Output 1 • Relay output • Voltage output (for driving SSR) • Current output Sampling Period • 250 ms This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207) E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers Communications Manual (Cat. No. H208) 2 E5CZ/E5CZ-U Model Number Structure Model Number Legend Controllers Option Units E5CZ-@2M@@ E53-CZ@@ 1 2 3 4 5 1 2 3 1. Applicable Controller CZ: E5CZ 2. Function 1 Blank: None H: Heater burnout/Heater short detection (CT1) 3. Function 2 B: Two event inputs 03: RS-485 communications 1. Control Output 1 R: Relay output Q: Voltage output (for driving SSR) C: Current output 2. Number of Alarms 2: Two alarms 3. Option Blank: None M: Option Unit can be mounted. 4. Input Type T: Thermocouple, infrared sensor/platinum resistance thermometer L: Analog current/voltage input 5. Power Supply Voltage Blank: 100 to 240 VAC D: 24 VAC/VDC Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-CZ@@). Ordering Information Controllers with Terminal Blocks Size Power supply voltage Input type Alarm output Mounting option units No Thermocouple or Resistance thermometer 2 Yes 100 to 240 VAC Analog (current/voltage) 1/16 DIN 48 × 48 × 78 (W × H × D) Thermocouple or Resistance thermometer 2 2 Yes Yes 24 VAC/VDC Analog (current/voltage) 2 Yes Control output Previous model New model Relay output E5CZ-R2 E5CZ-R2T Voltage output (for driving SSR) E5CZ-Q2 E5CZ-Q2T Relay output E5CZ-R2M E5CZ-R2MT Voltage output (for driving SSR) E5CZ-Q2M E5CZ-Q2MT Current output E5CZ-C2M E5CZ-C2MT Relay output None E5CZ-R2ML Voltage output (for driving SSR) None E5CZ-Q2ML Current output None E5CZ-C2ML Relay output E5CZ-R2MD E5CZ-R2MTD Voltage output (for driving SSR) E5CZ-Q2MD E5CZ-Q2MTD Current output E5CZ-C2MD E5CZ-C2MTD Relay output None E5CZ-R2MLD Voltage output (for driving SSR) None E5CZ-Q2MLD Current output None E5CZ-C2MLD Option Units One of the following Option Units can be mounted to provide the E5CZ with additional functions. Functions Previous model Communications RS-485 Communications RS-485 Heater burnout Event inputs New model E53-CN03N E53-CZ03 E53-CNH03N E53-CZH03 E53-CNBN E53-CZB Heater burnout Event inputs E53-CNHBN Note: Option Units cannot be used for plug-in models. These Option Units are applicable only to models released after October 2008. E53-CZHB 3 E5CZ/E5CZ-U Model Number Structure Model Number Legend (Plug-in-type Controllers) E5CZ-@2T@U 1 2 34 5 4. Power Supply Voltage Blank: 100 to 240 VAC D: 24 VAC/VDC 5. Plug-in type U: Plug-in type 1. Output Type R: Relay Q: Voltage output (for driving SSR) 2. Number of Alarms 2: Two alarms 3. Input Type T: Thermocouple, infrared sensor/platinum resistance thermometer Ordering Information (Plug-in-type Controllers) Plug-in-Type Controllers Size Power supply voltage Input type Alarm output 100 to 240 VAC Thermocouple or Resistance thermometer 2 24 VAC/VDC Thermocouple or Resistance thermometer 2 1/16 DIN Control output Relay output Previous model New model None E5CZ-R2TU Voltage output (for driving SSR) None E5CZ-Q2TU Relay output None E5CZ-R2TDU Voltage output (for driving SSR) None E5CZ-Q2TDU Accessories (Order Separately) Adapter USB-Serial Conversion Cable Model Connectable models E58-CIFQ1 Terminal Cover Connectable models Terminal block models Model E53-COV17 Sockets (for Plug-in Models) Type Waterproof Packing Model Y92S-29 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. Current Transformers (CTs) 4 Model Terminal block models Y92F-45 Note: Use this Adapter when the panel has been previously prepared for the E5B@. Hole diameter Model 5.8 dia. E54-CT1 12.0 dia. E54-CT3 Model Front-connecting Socket P2CF-11 Front-connecting Socket with Finger Protection P2CF-11-E Back-connecting Socket P3GA-11 Terminal Cover for Back-connecting socket with Finger Protection Y92A-48G E5CZ/E5CZ-U Specifications Ratings Power supply voltage Operating voltage range Power consumption 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz or 24 VDC 85% to 110% of rated supply voltage E5CZ 7.5 VA 5.5 VA (24 VAC)/3.5 W (24 VDC) E5CZ-U 6 VA 4.5 VA (24 VAC)/2.5 W (24 VDC) Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, or B Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Voltage input: 0 to 50 mV Sensor input Models with analog inputs Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω, Voltage input: 1 MΩ (Use a 1:1 connection when connecting the ES2-HB.) E5CZ SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA E5CZ-U SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA Voltage output E5CZ (for driving E5CZ-U SSR) Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with short-circuit protection circuit Current output E5CZ 4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 2,700 Relay output Control output SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA Alarm output Event input Contact input ON: 1 kΩ max., OFF: 100 kΩ min. Non-contact input ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Outflow current: Approx. 7 mA per point Control method ON/OFF control or 2-PID control (with auto-tuning) Setting method Digital setting using front panel keys Indication method 11-segment digital display and individual indicators (7-segments displays also possible) Character height: PV: 11 mm, SV: 6.5 mm Other functions Manual output, heating/cooling control, transfer output (on some models), loop break alarm, multi SP, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, etc. Ambient operating temperature −10 to 55°C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no icing or condensation) 5 E5CZ/E5CZ-U Input Ranges Thermocouples/Platinum Resistance Thermometers (Universal Inputs) Input Type Platinum resistance thermometer Name Pt100 Thermocouple JPt100 K J T E L Infrared temperature sensor U N R S B 10 to 70°C 60 to 120°C 115 to 165°C 140 to 260°C Temperature range (°C) Setting number 1700 1300 1700 1300 850 850 850 600 500.0 500.0 500.0 400.0 400 400.0 400 400.0 260 100.0 100.0 120 165 0 0 0 0 19 20 21 22 90 100 0.0 −200 −199.9 0 1 0.0 −199.9 2 3 0 −20.0 −100 −20.0 6 7 8 −200 4 5 The applicable standards for the input types are as follows: 0 0 16 17 −100 −200 −199.9 9 10 11 12 −200 −199.9 −200 13 14 15 U: Cu-CuNi, DIN 43710-1985 18 JPt100: JIS C 1604-1989, JIS C 1606-1989 L: Fe-CuNi, DIN 43710-1985 Models with Analog Inputs Input Type Current Voltage Input specification 4 to 20mA 0 to 20 mA 1 to 5 V Setting range Usable in the following ranges by scaling: −1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999 Setting number 0 1 2 0 to 5 V 3 0 to 10 V 4 23 Shaded settings are the default settings. Pt100: IEC 751 K, J, T, E, N, R, S, B: IEC584-1 6 0 to 50 mV Usable in the following ranges by scaling: −1999 to 9999 or −199.9 to 999.9 1800 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 −100.0 −200.0 Analog input Shaded settings are the default settings. E5CZ/E5CZ-U Alarm Types Select alarm types out of the 12 alarm types listed in the following table. Set value 0 1 (See note 1.) 2 3 Alarm output operation Alarm type Alarm function OFF Output OFF Upper- and lowerlimit ON OFF Upper limit ON OFF Lower limit ON OFF L H (See note 2.) SP H0, L
E5EZ-R3HMLAC100-240
物料型号: - OMRON公司生产的数字温度控制器E5@Z系列,包括E5CZ、E5EZ和E5AZ型号。

器件简介: - 这些控制器是用于精确控制温度的设备,具有多种输入选项,包括温度输入和模拟输入。 - 它们具备多种功能,如环路断裂报警(LBA)、手动输出和传输输出。

引脚分配: - 控制器具有多种输入/输出选项,包括事件输入、传感器输入、控制输出和报警输出。

参数特性: - 显示类型:11段显示,易于阅读。 - 采样速度:250毫秒。 - 设置工具端口作为标准特性,便于与个人电脑连接。 - 安装了新的通信协议Modbus。

功能详解: - 提供了多种控制输出选项,包括继电器输出、电压输出(用于驱动SSR)和电流输出。 - 具备自动/手动切换功能。 - 某些型号还具备RS-485通信能力。

应用信息: - 广泛应用于需要精确温度控制的场合,如工业自动化、医疗设备等。

封装信息: - 提供了1/16 DIN、1/8 DIN和1/4 DIN的尺寸选项。
E5EZ-R3HMLAC100-240 价格&库存

很抱歉,暂时无法提供与“E5EZ-R3HMLAC100-240”相匹配的价格&库存,您可以联系我们找货