0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E6B2CWZ6C300PR05M

E6B2CWZ6C300PR05M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    n/a

  • 数据手册
  • 价格&库存
E6B2CWZ6C300PR05M 数据手册
Incremental 40-mm-dia. Rotary Encoder E6B2-C CSM_E6B2-C_DS_E_6_1 General-purpose Encoder with External Diameter of 40 mm • Incremental model • External diameter of 40 mm. • Resolution of up to 2,000 ppr. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 4. Ordering Information Encoders [Refer to Dimensions on page 4.] Power supply voltage Output configuration 5 to 24 VDC NPN open-collector output 12 to 24 VDC PNP open-collector output Resolution (pulses/rotation) 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 720, 800, 1,000, 1,024 1,200, 1,500, 1,800, 2,000 100, 200, 360, 500, 600 Voltage output 2,000 1,000 1,200, 1,500, 1,800, 2,000 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 5 VDC Line-driver output E6B2-CWZ6C (resolution) 0.5M Example: E6B2-CWZ6C 10P/R 0.5M E6B2-CWZ5B (resolution) 0.5M Example: E6B2-CWZ5B 100P/R 0.5M 1,000 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 5 to 12 VDC Model 1,000, 1,024 1,200, 1,500, 1,800, 2,000 E6B2-CWZ3E (resolution) 0.5M Example: E6B2-CWZ3E 10P/R 0.5M E6B2-CWZ1X (resolution) 0.5M Example: E6B2-CWZ1X 10P/R 0.5M Accessories (Order Separately) [Refer to Dimensions on Rotary Encoder Accessories.] Name Couplings Flanges Servo Mounting Bracket Model Remarks E69-C06B Provided with the product. E69-C68B Different end diameter E69-C610B Different end diameter E69-C06M Metal construction E69-FBA E69-FBA02 E69-2 --E69-2 Servo Mounting Bracket provided. --- Note: 1. Refer to Rotary Encoders Accessories on your OMRON website for details. 2. Refer to Precautions For Correct Use of Rotary Encoders on your OMRON website when using the Rotary Encoders together with a Coupling. 1 E6B2-C Ratings and Specifications Item E6B2-CWZ6C E6B2-CWZ5B E6B2-CWZ3E Power supply voltage Model 5 VDC −5% to 24 VDC +15%, ripple (p-p): 5% max. 12 VDC −10% to 24 VDC +15%, ripple (p-p): 5% max. 5 VDC −5% to 12 VDC +10%, ripple (p-p): 5% max. Current consumption *1 80 mA max. 100 mA max. Resolution (pulses/rotation) 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 100, 200, 360, 500, 600, 720, 800, 1,000, 1,024, 1,000, 2,000 1,200, 1,500, 1,800, 2,000 Output phases Phases A, B, and Z Phase difference between outputs 90°±45° between A and B (1/4 T ± 1/8 T) Output configuration NPN open-collector output PNP open-collector output Voltage output (NPN output) Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Applied voltage: 30 VDC max. Source current: 35 mA max. Residual voltage: 0.4 V max. (at source current of 35 mA) AM26LS31 equivalent Output current Output resistance: 2 kΩ High level: IO = −20 mA Sink current: 20 mA max. Low level: IS = 20 mA Residual voltage: 0.4 V max. Output voltage: (at sink current of 20 mA) VO = 2.5 V min. VS = 0.5 V max. Maximum response frequency *3 100 kHz 50 kHz 100 kHz 1 μs max. (Control output Rise and fall times voltage: 5 V, Load resisof output tance: 1 kΩ, Cable length: 2 m max.) E6B2-CWZ1X 5 VDC ±5%, ripple (p-p): 5% max. 160 mA max. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 1,000, 1,200, 1,500, 1,800, 2,000 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 Phases A, A, B, B, Z, and Z 1 μs max. (Cable length: 2 m max., Sink current: 10 mA) Starting torque 0.98 mN·m max. Moment of inertia 1×10−6 kg·m2 max.; 3 × 10−7 kg·m2 max. at 600 P/R max. Shaft loading Radial 30 N Thrust 20 N Line driver output *2 0.1 μs max. (Cable length: 2 m max., IO = −20 mA, IS = 20 mA) Maximum 6,000 r/min permissible speed Protection circuits Power supply reverse polarity protection, Load short-circuit protection --- Ambient Operating: −10 to 70°C (with no icing), Storage: −25 to 85°C (with no icing) temperature range Ambient humidity range Operating/Storage: 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each in X, Y, and Z directions Shock resistance Destruction: 1,000m/s2 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 500 mm) Materials Case: ABS, Main unit: Aluminum, Shaft: SUS420J2 Weight (packed state) Approx. 100 g Accessories Coupling, Hexagonal wrench, Instruction manual *1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON. *2. The line driver output is a data transmission circuit compatible with RS-422A and long-distance transmission is possible with a twisted-pair cable. The quality is equivalent to AM26LS31. *3. The maximum electrical response speed is determined by the resolution and maximum response frequency as follows: Maximum response frequency × 60 Maximum electrical response speed (rpm) = Resolution This means that the E6B2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical response speed. 2 E6B2-C I/O Circuit Diagrams Model/Output Circuits Output mode Connection E6B2-CWZ6C Brown 5 VDC -5% to 24 VDC +15% Black, white, orange NPN transistor 35 mA max. at 30 VDC max. E6B2 main circuit 3.3 Ω Output signal (Black: phase A, White: phase B, Orange: phase Z) Blue GND E6B2-CWZ5B Brown 12 VDC −10% to 24 VDC +15% 3.3 Ω 35 mA max. Black, white, orange PNP transistor Direction of rotation: CW (as viewed from end of shaft) 0V Shield E6B2 main circuit E6B2-CWZ6C NPN Open-collector Output Model E6B2-CWZ5B PNP Open-collector Output Model Output signal (Black: phase A, White: phase B, Orange: phase Z) Blue T(360˚) CW ON Phase A OFF Phase B ON OFF Phase Z ON OFF ON Phase B OFF 1/4±1/8T (90˚±45˚) ON Phase Z OFF Note: Phase A is 1/4 T ± 1/8 T faster than phase B. 1/4±1/8T (90˚±45˚) Color Brown Note: Phase A is 1/4 T ± 1/8 T slower than phase B. The ONs in the above timing chart mean that the output transistor is ON and the OFFs mean that the output transistor is OFF. Black White Orange Blue Terminal Power supply (+Vcc) Output phase A Output phase B Output phase Z 0 V (common) E6B2-CWZ3E Voltage Output Model Direction of rotation: CW (as viewed from end of shaft) Brown 5 VDC −5% to 12 VDC +10% 2 kΩ Black, white, orange 3.3 Ω CCW GND E6B2-CWZ3E NPN transistor T(360˚) ON Phase A OFF 0V Shield E6B2 main circuit Direction of rotation: CCW (as viewed from end of shaft) Output signal (Black: phase A, White: phase B, Orange: phase Z) 20 mA max. Blue 0V Shield GND T(360˚) H Phase A L H Phase B L H Phase Z L Direction of rotation: CCW (as viewed from end of shaft) CW T(360˚) H Phase A L H Phase B L 1/4±1/8T(90˚±45˚) H Phase Z L Note: Phase A is 1/4 T ± 1/8 T faster than phase B. CCW 1/4±1/8T(90˚±45˚) Note: Phase A is 1/4 T ± 1/8 T slower than phase B. “H” and “L” in the diagrams are the output voltage levels of phases A, B, and Z. E6B2-CWZ1X E6B2-CWZ1X Line Driver Output Model Direction of rotation: CW (as viewed from end of shaft) Color Direction of rotation: CCW (as viewed from end of shaft) Brown Black Brown T(360˚) 5 VDC ±5% Black, white, orange E6B2 main circuit AM26 LS31 equivalent Non-reversed output (Black: phase A, White: phase B, Orange: phase Z) L H 0V GND Phase B Reversed output (Black/red: Phase A, White/red: Phase B, Orange/red: Phase Z) Shield Phase B H L H Phase Z L H Phase A L Black, white, orange (with red stripe) Blue Phase A CW T(360˚) Phase A H L H Phase B L 1/4±1/8T (90˚±45˚) H Phase Z L H Phase A L H L H Phase Z L Note: Phase A is 1/4 T ± 1/8 T faster than phase B. CCW Black/red stripes White 1/4±1/8T (90˚±45˚) H L H Phase Z L Phase B Note: Phase A is 1/4 T ± 1/8 T slower than phase B. “H” and “L” in the diagrams are the output voltage levels of phases A, B, and Z. White/red stripes Orange Orange/ red stripes Blue Terminal Power supply (+Vcc) Output phase A Output phase A Output phase B Output phase B Output phase Z Output phase Z 0 V (common) Note: Receiver: AM26LS32 equivalent Note: 1. The shielded cable outer core (shield) is not connected to the inner area or to the case. 2. The phase A, phase B, and phase Z circuits are all identical. 3. Normally, connect GND to 0 V or to an external ground. 3 E6B2-C Safety Precautions Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Safe Use Incorrect wiring may damage internal circuits. Precautions for Correct Use Do not use the Encoder under ambient conditions that exceed the ratings. ● Mounting • Do not extend the length of the cable to more than 2 m. If the cable must be more than 2 m, use a Model with a Line-driver Output (max. length: 100 m). • Origin Indication It is easy to adjust the position of phase Z with the origin indication function. The following illustration shows the relationship between phase Z and the origin. Set cut face D to the phase Z origin as shown in the illustration. ● Wiring Spurious pulses may be generated when power is turned ON and OFF. Wait at least 0.1 s after turning ON the power to the Encoder before using the connected device, and stop using the connected device at least 0.1 s before turning OFF the power to the Encoder. Also, turn ON the power to the load only after turning ON the power to the Encoder. Phase Z origin Origin 120˚ 120˚ Cut face D 30±0.2 dia. (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified. Encoder E6B2-C Origin of phase Z 120˚ Three, M3 holes; Depth: 7 mm 15 10 39 0 6-0.012 dia. 120˚ 0 -0.021 40 dia. 20 dia. 30±0.2 dia. 5 1 7.5 *E6B2-CWZ6C/5B/3E: 5-dia. vinyl-insulated round cable with 5 conductors (Conductor cross section: 0.2 mm2, Insulation diameter: 1.0 mm), Standard length: 0.5 m E6B2-CWZ1X: 5-dia. vinyl-insulated round cable with 8 conductors (Conductor cross section: 0.2 mm2, Insulation diameter: 1.0 mm), Standard length: 0.5 m * 8 Accessories (Order Separately) Couplings E69-C06B E69-C68B E69-C610B E69-C06M Flanges E69-FBA E69-FBA02 Servo Mounting Bracket E69-2 Refer to Rotary Encoders Accessories on your OMRON website for details. 4 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2017.7 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2017 All Right Reserved.
E6B2CWZ6C300PR05M 价格&库存

很抱歉,暂时无法提供与“E6B2CWZ6C300PR05M”相匹配的价格&库存,您可以联系我们找货

免费人工找货