0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E8EB-01C

E8EB-01C

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    Module

  • 描述:

    SENSOR PRESSUR 1-5V 0-980KPA NPN

  • 数据手册
  • 价格&库存
E8EB-01C 数据手册
Slim Pressure Sensor E8EB CSM_E8EB_DS_E_2_1 Ideal for Workpiece Position and Original Pressure Checking • The 0 to 100 kPa model can be used for workpiece position checking. • The 0 to 1MPa model is ideal for original pressure checking. • Degree of protection conforms to IEC IP54. Be sure to read Safety Precautions on page 6. Ordering Information Pressure range Positive pressure Positive pressure Negative pressure 0 to 1 MPa 0 to 100 kPa 0 to −100 kPa ON/OFF output NPN open collector PNP open collector E8EB-10C E8EB-10B E8EB-01C E8EB-01B E8EB-N0C2B E8EB-N0B2B Linear output 1 to 5 V 1 E8EB Ratings and Specifications Item Model Power supply voltage Current consumption Pressure type Permissible pressure range Pressure setting range Withstand pressure Applicable fluid Repeat accuracy (ON/OFF output) Accuracy (linear output) Hysteresis (linear output) Differential travel (ON/OFF output) Linearity (linear output) Response time Linear output ON/OFF output Load current Output applied voltage Residual voltage Indicator Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Pressure inlet Connection method Weight (packed state) Pressure port material Accessories E8EB-10C E8EB-10B E8EB-01C E8EB-01B E8EB -N0C2B* E8EB -N0B2B* 24 VDC ±10% with a ripple (p-p) of 5% max. 20 mA max. Gauge pressure 0 to 100 kPa 0 to −100 kPa 0 to 1 MPa 0 to 100 kPa 0 to −100 kPa 2 MPa 290 kPa 0 to 1 MPa Noncorrosive and nonflammable gases ±1% FS max. ±3% FS max. ±1% FS max. 0.4 to 1.6% FS max. ±1% FS max. 5 ms max. 1 to 5 V with an output impedance of 20 Ω and a permissible resistive load of 10 kΩ min. NPN open PNP open NPN open PNP open NPN open PNP open collector collector collector collector collector collector 80 mA max. 30 VDC max. NPN: 0.4 V max. (at the load current of 20 mA) and 1 V max. (at the load current of 80 mA) PNP: 1.5 V max. (at the load current of 20 mA) and 2 V max. (at the load current of 80 mA) Operation indicator (red) Operating: −10°C to 55°C (with no icing) Storage: −25°C to 70°C (with no icing) Operating: 35% to 85% (with no condensation) ±0.12% FS/°C between 0°C and ±0.2% FS/°C between 0°C and 50°C 50°C ±0.2% FS/°C max. between ±0.3% FS/°C max. between −10°C and 0°C or 50°C and 55°C −10°C and 0°C or 50°C and 55°C ±1% FS max. 100 MΩ min. (at 500 VDC) between current carry parts and case 500 VAC for 1 min between current carry parts and case Destruction: 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s2 whichever is smaller, for 2 hours each in X, Y, and Z directions Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions IEC 60529 IP54 Rc(PT)1/8 Pre-wired (standard cable length: 2 m) Approx. 120 g Zinc die-cast Instruction manual * These models are negative-pressure models. 2 E8EB Engineering Data (Typical) Differential Travel vs. Pressure +5 1.4 1.2 0 1.0 −5 0.8 0.6 (−10) 0 20 40 Operating pressure fluctuation (% FS) +10 −10 −20 (55) 60 0 50 Temperature (ºC) 6 5 4 3 +0.5 0 −0.5 24 27.6 Pressure (kPa) Voltage (V) Linear Output Fluctuation vs. Temperature E8EB-01C Linear output fluctuation (% FS) E8EB +1.0 −1.0 20.4 100 Linearity E8EB-01C +10 Linearity deviation (%FS) Linear Output Voltage vs. Pressure Linear output voltage (V) Operating Pressure Fluctuation vs. Voltage E8EB-01C E8EB-01C Differential travel (%FS) Operating pressure fluctuation (%FS) Operating Pressure Fluctuation vs. Temperature E8EB-01C +5 0 +0.8 +0.4 0 2 −5 −0.4 1 −10 0 20 0 −20 0 0.2 40 −40 0.4 60 −60 0.6 80 100 Pressure (kPa) −80 −100 −20 (−10) 0 20 40 (55) 60 Temperature (ºC) −0.8 0 25 50 75 100 Pressure (kPa) Pressure (kPa) 0.8 1 Pressure (MPa) Linear output fluctuation (% FS) Linear Output Fluctuation vs. Voltage E8EB-01C +10 +5 0 −5 −10 20.4 24 27.6 Voltage (V) 3 E8EB Gap Measurement When checking the gap between the workpiece and the nozzle as shown in the illustration, the output of the E8EB varies with the surface roughness of the workpiece or the dimensions of the nozzle. Workpiece Nozzle length Gap Nozzle diameter Air supply 6 5 1.6-S∇∇∇ Influence of Nozzle Diameter Conditions Nozzle dia.: 2 mm Nozzle length: 10 mm Air pressure: 100 kPa 4 25-S∇∇∇ 3 Linear output voltage (V) Linear output voltage (V) Examples with E8EB-01C (Typical) Influence of Surface Roughness of Workpieces 6 Influence of Nozzle Length Conditions Nozzle dia.: 10 mm Surface roughness of workpiece: 1.6-S∇∇∇ Air pressure: 100 kPa 5 1 dia. 4 Linear output voltage (V) E8EB 6 Conditions Nozzle dia.: 1 mm Surface roughness of workpiece: 1.6-S∇∇∇ Air pressure: 100 kPa 5 4 20 mm 3 3 2 dia. 10 mm 3 dia. 2 2 mm 2 2 50-S∇ 1 50 100 150 200 250 Gap (µm) • The output varies with the surface roughness of the workpiece even though the gap is constant. • The rougher the surface of the workpiece is, the more noticeable the variation of output is with a small gap. The variation rate versus gap change is not large in such cases. 1 50 100 150 200 250 Gap (µm) • The larger the nozzle diameter is, the larger the variation rate of output versus gap change is. 1 50 100 150 200 250 Gap ( µ m ) • The smaller the nozzle length is, the larger the variation rate of output versus gap change is. 4 E8EB I/O Circuit Diagrams NPN Output Model Timing Charts Output Circuit 1,000,100 Pressure (kPa) E8EB-10C E8EB-01C Setting 0 Output ON OFF Operation Lit indicator (red) Not lit 0 Operation indicator (red) Brown Pressure Sensor main circuit White (ON/OFF) Black (linear output) Load Setting Pressure (kPa) Blue −100 E8EB-N0C2B +24 V Load 0V ON Output OFF Operation Lit indicator (red) Not lit PNP Output Model Timing Charts Output Circuit 1,000,100 Pressure (kPa) E8EB-10B E8EB-01B Setting 0 Output ON OFF Operation Lit indicator (red) Not lit Operation indicator (red) Pressure Sensor main circuit Brown +24 V White (ON/OFF) Black (linear output) 0 Load Load Pressure (kPa) E8EB-N0B2B Setting 0V Blue −100 ON Output OFF Operation Lit indicator (red) Not lit 5 E8EB Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons. Do not use it for such purposes. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. ● Mounting • If the diaphragm is damaged, the Pressure Sensor will not operate properly. Do not insert a screwdriver or steel wire into the interior of the pressure-sensitive parts through the pressure port. • The pressure inlet has an R (PT) 1/8 taper screw and M5 female screw that conforms to JIS Standards. Apply sealing tape around the female taper screw so that no pressure leakage will occur. • The most-suitable wrench is 17 mm in size. • Make sure that the tightening torque of the M5 female screw is 9.8 N·m or less. ● Adjustment Pressure Setting • After the pressure is set with the pressure adjuster, cover the adjuster with the rubber bushing so that no dust or any other foreign material will penetrate into the interior of the E8EB. Dimensions (Unit: mm) E8EB 21 8.5 12.8 dia. 3.5 * 3.7 7 dia. 5.2 x 5.2 19±0.1 33.2 44 17 30 Rc (PT) 1/8 Pressure adjuster Two, 4.4-dia. holes 10.9 17.5 1.5 Operation indicator (red) 16.4 *3.8-dia. vinyl-insulated round cable with 4 conductors, (Conductor cross-section: 0.2 mm2, Insulator diameter: 1.0 mm); Standard length: 2 m In the interest of product improvement, specifications are subject to change without notice. 6
E8EB-01C 价格&库存

很抱歉,暂时无法提供与“E8EB-01C”相匹配的价格&库存,您可以联系我们找货

免费人工找货