E8F2D10C

E8F2D10C

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Pressure Sensor 1V to 5V 0psi to 145psi Gage

  • 数据手册
  • 价格&库存
E8F2D10C 数据手册
E8F2 Pressure Sensor “Cube-Type” Pressure Sensor, with LED Display, Offers High-Precision Sensing H New psi version available H Compact style: 28 x 28 x 29 mm (1.10 x 1.10 x 1.14 in) saves mounting space H Easy-to-read LEDs H Displays both analog bar and digital pressure values H Two independent discrete outputs available—plus one analog output H Select either NPN and PNP output type Ordering Information J SENSORS Type Digital output Analog output Pressure range Part number Positive pressure NPN open collector (independent, two outputs) 1 to 5 V 0 to 100 kPa E8F2-A01C 0 to 1 MPa E8F2-B10C 0 to 14.5 psi E8F2-D01C 0 to 145 psi E8F2-D10C 0 to 100 kPa E8F2-A01B 0 to 1 MPa E8F2-B10B 0 to -- 101 kPa E8F2-AN0C 0 to -14.6 psi E8F2-DN0C 0 to-101 kPa E8F2-AN0B PNP open collector (independent, two outputs) Negative pressure NPN open collector (independent, two outputs) PNP open collector (independent, two outputs) J ACCESSORIES (ORDER SEPARATELY) Description Part number Panel-mounting bracket E89-F4 2 E8F2 E8F2 Application Examples J CHIP ATTACHMENT CHECKS J AIR PRESSURE CHECKS J PCB AND WAFER ATTACHMENT CHECKS E8F2 E8F2 E8F2 Specifications J RATINGS/CHARACTERISTICS Item E8F2A01C E8F2B10C E8F2AN0C E8F2D01C E8F2D10C E8F2DN0C E8F2A01B E8F2B10B E8F2AN0B Power supply voltage 12 to 24 VDC ± 10% with a ripple (p-p) of 10% max. Current consumption 70 mA max. (See Note 1.) Pressure type Gauge pressure Rated pressure range 0 to 100 kPa 0 to 1 MPa 0 to -- 101 kPa 0 to 14.5 psi 0 to 145 psi 0 to -- 14.6 psi 0 to 100 kPa 0 to 1 MPa 0 to -- 101 kPa Pressure setting range 0 to 100 kPa 0 to 1 MPa 0 to -- 101 kPa 0 to 14.5 psi 0 to 145 psi 0 to -- 14.6 psi 0 to 100 kPa 0 to 1 MPa 0 to -- 101 kPa Withstand pressure 400 kPa 1.5 MPa 400 kP 58 psi 217.6 psi 58 psi 400 kPa 1.5 MPa 400 kPa Applicable fluid Non-corrosive gas and non-flammable gas Operating mode(s) Hysteresis mode Window mode Auto-teaching mode Repeat accuracy (ON/OFF output) ±1% FS max. Linearity ±1% FS max. Response time (ON/OFF output) 5 ms max. Linear output 1 to 5 V± 5% FS with an output impedance of 1 kΩ and a permissible resistive load of 500 kΩ min. ON/OFF output NPN open collector (NO/NC) Load current: 30 mA max. Output applied voltage: 30 VDC max. Residual voltage: 1 V max. with a load current of 30 mA Display (See Note 2.) 3.5-digit red LED Green LED bar indicator The orange LED is lit for two independent outputs with output transistor turned ON Green unit indicator Display accuracy ±3% FS ± 1 digit max. Circuit protection Reverse polarity connection, load short-circuiting 3 E8F2 E8F2 Item E8F2A01C E8F2B10C E8F2AN0C E8F2D01C Temperature influence ±3% FS max. Ambient temperature Operating: 0°C to 55°C (32°F to 131°F) E8F2D10C E8F2DN0C E8F2A01B E8F2B10B E8F2AN0B Storage: -- 10°C to 60°C (14°F to 140°F) with no icing Ambient humidity Operating/Storage: 35% to 85% (with no condensation) Voltage influence ±1.5% FS max. Insulation resistance 100 MΩ min. (at 500 VDC) between current-carry parts and case Dielectric strength 1,000 VAC at 1 min Vibration resistance Destruction: 10 to 500 Hz, 1.0-mm double amplitude or 150 m/s2, 3 times each for 11 min in X, Y,and Z directions Shock resistance 300 m/s2 (30G) 3 times each in X, Y, and Z directions Degree of protection IEC60529, IP50 Pressure port 1/8 NPT male screw and M5 female screw Connection method Pre-wired (standard length: 2 m) Cable Approved by UL Weight (incl. packing material) Approx. 110 g (3.88 oz) Material Pressure port: aluminum die cast Case: heat-resistant ABS Accessories Mounting bracket Instruction sheet Note: 1. The current consumption is approximately 43 mA in energy-saving mode. 2. Display Example of Digital Indicator Model Setting unit kPa psi Applied Digital display pressure Applied Digital display pressure E8F2-A01C/E8F2-A01B E8F2-B10C/E8F2-B10B 100 1,000 1 1 0 0 0 0 0 0 E8F2-AN0C/E8F2-AN0B -- 101 -- 1 0 1 0 E8F2-D01C 14.5 1 4 5 0 E8F2-D10C 145 1 4 5 0 E8F2-DN0C -14.5 -1 4 6 0 Note: The “.” in the display indicates the decimal point. Its position will not change unless the setting unit is changed. 4 E8F2 E8F2 Engineering Data E8F2-A01C E8F2-A01C Pressure 0 Operating pressure fluctuation (% FS) J TEMPERATURE VS. OPERATING PRESSURE FLUCTUATION (TYPICAL) Linear output fluctuation (% FS) J TEMPERATURE VS. LINEAR OUTPUT CURRENT FLUCTUATION (TYPICAL) Rated pressure Temperature (°C) Temperature (°C) J LINEARITY (TYPICAL) E8F2-A01C E8F2-A01C Linear output voltage (V) Linearity deviation (%FS) J PRESSURE VS. LINEAR OUTPUT (TYPICAL) Pressure (kPa) Pressure (kPa) 5 E8F2 E8F2 Nomenclature J E8F2 PRESSURE SENSOR (PSI TYPE) (1) (2) (3) (4) OUT1 OUT2 kPa Torr Psi (5) (6) (7) (8) Display Panel 1. Bar indicator (green) Indicates the degree of the measured pressure according to the the set pressure. 2. Numeric and menu display (red) Indicates measurement values and menu setting items. 3. Unit indicator (green) Indicates the unit used for detection; the indicator shows which unit is the one currently set. 4. OUT1 indicator (orange) OUT1 indicator turns ON when OUT1 is turned ON. 5. OUT2 indicator (orange) OUT2 indicator turns ON when OUT2 is turned ON. Operation 6. Up key 7. Down key Both the Up and the Down key are used to select or change the set items, set contents, and set values in setting mode. • Press either key (Up or Down key) to check the ON and OFF points in measurement mode. The values are reset by pressing both keys simultaneously. • Use either the Up or the Down key (as necessary) together with the SET key for setting the Sensor to a special setting mode or energy-saving mode. 8. SET key • Used for entering the set contents and set values in setting mode. • Used for setting the Sensor to basic setting mode or pressure setting mode. • 6 E8F2 E8F2 Operation J OUTPUT STAGE CIRCUIT Output type NPN output (normally open) Model E8F2-A01C E8F2-B10C E8F2-AN0C Timing chart Hysteresis mode Pressure Pressure ON point ON point OFF point OFF point Output OUT indicator (orange) Window mode NPN output (normally closed) ON Output OFF OUT ON indicator (orange) OFF ON OFF Pressure Pressure OFF point OFF point OFF point - 10% FS max. ON point - 10% FS max. ON point Output OUT indicator (orange) ON Output OFF OUT ON indicator (orange) OFF ON OFF Output circuit 12 to 24 V Brown Load 30 mA max. Black Load (ON/OFF1) Pressure Sensor main circuit ON point 30 mA max. White (ON/OFF2) Gray 1 to 5 V (linear) Load Blue 0V 7 OFF point - 10% FS max. ON point - 10% FS max. E8F2 E8F2 J FUNCTIONS AND SETTINGS Function/Setting Description Zero-reset function Sets the measurement value to 0 when the Sensor is exposed to the air. Basic setting mode Unit setting Changes the unit for detection. Pressure setting method --- Output-type setting Selects normally-open or normally-closed output. Pressure setting mode Manual setting Sets the ON and OFF points manually. Auto-teaching setting Automatically sets the ON and OFF points depending upon the actual sensing of objects. Special setting mode Key-protect setting Protects the set value against the incorrect operation of the keys. Prevents the set value against the careless operation of the keys. Hysteresis width setting Changes the hysteresis range. Window range setting Changes the window mode setting. Display refresh interval setting Changes the display refresh interval to make the displayed value easier to see. Measurement value averaging time setting Prevents incorrect output due to sudden, instantaneous changes that may occur with pressure. Special setting mode LED bar indicator range setting Changes the display range of the LED bar indicator in hysteresis mode. Energy saving Energy-saving mode Energy-saving function 1 Displays the LED bar indicator but turns the red LED display OFF. Energy-saving function 2 The LED bar indicator and red LED display flash in window mode if the measured value exceeds the set range. ON/OFF set value check function Checks the set ON and OFF points. J SETTINGS Digital Display The E8F2 displays alphanumeric characters, such as the measurement values and menu items, with 7-segment LEDs. Refer to the examples shown below. The following abbreviations are used for the digital display of the Controller. Abbreviation Meaning Abbreviation Meaning Unt Unit DSP Display In output operation M-A Manual/Auto AVE Average Unit (kPa) OPE Operation BAR Bar Width PRT Protect AUT Auto HYS Hysteresis ECO Economy WID Width Display Meaning ope kpa wid a b c d e f g h i j k l m n o p A B C D E F G H I J K L M N O P 8 Q r s t u U w x y = R S T U V W X Y Z E8F2 E8F2 J MODES In addition to displaying measurement values, the E8F2 has a variety of functions. These functions are available in four main modes as described below: Measurement Mode, Basic Setting Mode, Pressure Setting Mode, Special Setting Mode. Three functions are available in measurement mode. For the relationships among each mode and for switching methods, refer to the following figure. Power ON Zero-reset function Energy-saving function 1 No key operation or ON- and OFF-point check function Measurement Mode No key operation Energy-saving function 2 or or or Pressure Setting Mode Basic Setting Mode Manual setting unt: Measurement unit selection m-a: Pressure setting method selection ope: Output-type selection Special Setting Mode Auto-teaching setting on: OUT1 ON-point setting t.h1: OUT1 two-point teaching off: OUT1 OFF-point setting t.w: OUT1 one-point teaching on: OUT2 ON-point setting t.h1: OUT2 two-point teaching off: OUT2 OFF-point setting t.w: OUT2 one-point teaching prt: Key-protect setting hys: Hysteresis width setting wid: Window width setting dsp: Measurement value display refresh interval setting aUe: Number of measurement times setting for measurement value averaging bar: LED bar indicator range setting Note: 1. and indicate that the key must be pressed for approximately 2 or 3 s respectively. 2. The following will result when the E8F2 in basic, pressure setting, or special setting mode is reset to measurement mode. : The set values are entered. : The set values are not entered (left as they are). *1.Manual setting is available by selecting m (manual) in the pressure setting method selection in basic setting mode. *2.Auto-teaching setting is available by selecting a (auto-teaching) in the pressure setting method selection in basic setting mode. 9 E8F2 E8F2 Zero-reset Function Use the zero-reset function with the Sensor exposed to the air. OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Normal Measurement mode OUT1 OUT2 kPa Torr Psi Error The displayed measurement value is reset to 0 by pressing the Up and Down keys simultaneously. The reset range is within ±5% (FS) of the rated pressure. If the value is not within the range, an error will be displayed and the reset will not be enabled. Basic Setting Mode The unit of measurement, pressure setting method, and output type are set in basic setting mode. Setting item Measurement mode OUT1 OUT2 kPa Torr Psi Setting item Unit setting OUT1 OUT2 kPa Torr Psi Pressure setting method selection OUT1 OUT2 kPa Torr Psi Output-type setting OUT 1 OUT 2 kPa Torr Psi kPa Torr Psi 1. Press the SET key for approximately 2 s so that the E8F2 will be set to basic setting mode and unt will be displayed. 2. Set the items unt, m--a, and ope with Up or Down key. 10 E8F2 E8F2 Unit Setting Unit setting in E8F2-AN0C kPa OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi 1. Press the SET key while unt is displayed to display the unit presently set. 2. Press the Up or Down key to select the unit. 3. Press the SET key to select the displayed unit and display unt again. 4. Press the Up and Down keys simultaneously, to display unt again without selecting the unit. Pressure Setting Method Selection Pressure setting Setting item Manual setting OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Auto-teaching OUT1 OUT2 kPa Torr Psi or m: Manual setting (The ON and OFF points are manually set.) a: Auto-teaching (The ON and OFF points are set automatically.) 1. Press the SET key while m--a is displayed to display the pressure setting method presently set. 2. Press the Up or Down key to select the pressure setting method. 3. Press the SET key to select the displayed pressure setting method and display m--a again. 4. Press the Up and Down keys simultaneously to display m--a without selecting the unit. 11 E8F2 E8F2 Output-Type Setting or Output-type setting Setting item OUT1 OUT1 N.O OUT2 kPa Torr Psi OUT1 OUT2 N.O OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi or or OUT1 N.C OUT1 OUT2 N.C OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi no: Normally open nc: Normally closed 1. Press the SET key while ope is displayed to display the output type of OUT1 presently set. 2. 3. 4. 5. 6. Press the Up or Down key to select the output type. Press the SET key to select the displayed output type and display the output type of OUT2 presently set. Press the Up or Down key to select the output type. Press the SET key to select the displayed output type and display ope again. Press the Up and Down keys simultaneously to display ope again without selecting the unit. Returning to Measurement Mode Setting item Unit setting OUT1 OUT2 kPa Torr Psi Pressure setting or OUT1 OUT2 kPa Torr Psi Output configuration or Entered OUT1 OUT2 kPa Torr Psi Not entered • Entering the Setting Item: Press the SET key for approximately 2 s to enter the item that has been set. • Not Entering the Setting Item: Press the Up and Down keys simultaneously so that the item set will not be entered. 12 Measurement mode E8F2 E8F2 Pressure Setting Mode The E8F2 provides output according to the measured values to control external devices, such as valves and pumps. In order to control the external devices, a reference value can be set so that the output will be ON or OFF if the measured values are above or below the reference value. The output ON- and OFF-point settings are described below, provided that the output is normally open. Note: The ON and OFF points are set in pressure setting mode manually or through auto-teaching. Normally Open Window mode ON Output Output Hysteresis mode OFF OFF-point ON-point set value set value ON OFF ON-point OFF-point set value set value Pressure value Pressure value Normally Closed Window mode ON Output Output Hysteresis mode OFF OFF-point ON-point set value set value ON OFF Pressure value ON-point OFF-point set value set value Pressure value Manual Setting Note: Manual setting will be possible if m is selected in pressure setting method selection in basic setting mode. Manual setting Measurement mode Torr Psi Torr Psi Torr Psi Torr Psi or Displayed alternately OUT1 ON Torr Psi Displayed alternately OUT1 OFF Torr Psi Displayed alternately Displayed alternately OUT12 ON OUT12 OFF Torr Psi Press the Up or Down key to change the set value. 1. 2. 3. 4. 5. 6. 7. 8. 9. Press the SET key, to set the E8F2 to pressure setting mode and display the OUT1 ON point and on alternately. Press the Up or Down key to change the OUT1 ON point. Press the SET key to select the ON point and display the OUT1 OFF point and off alternately. Press the Up or Down key to change the OUT1 OFF point. Press the SET key to select the displayed OFF point and display the OUT2 ON point and on alternately. Press the Up or Down key to change the OUT2 ON point. Press the SET key to select the ON point and display the OUT2 OFF point and off alternately. Press the Up or Down key to change the OUT2 OFF point. Press the SET key to select the OFF point and display the OUT1 ON point and on alternately. Returning to Measurement Mode • Entering the Setting Item: Press the SET key for approximately 2 s to enter any item that has been “set.” • Not Entering the Setting Item: Press the Up and Down keys simultaneously, so any item “set” will not be entered. 13 Torr Psi E8F2 E8F2 Auto-teaching Auto-teaching allows input measured values to be input as ON- and OFF-point set values instead of key input. One- or two-point autoteaching can be selected. ON OFF Two-point teaching Output Output One-point teaching ON Pressure value OFF Pressure value Note: Auto-teaching will be possible if a is selected in the pressure setting method selection in basic setting mode. 1. Press the SET key to set the E8F2 to pressure setting mode and to display OUT1 and t.h1. 2. Press the Up or Down key to select the one-point teaching or two-point teaching method of OUT1 and OUT2. Setting item Measurement mode OUT1 OUT2kPa Torr Psi Auto-teaching OUT1 two-point teaching OUT1 one-point teaching OUT1 OUT2kPa Torr Psi OUT1 OUT2 OUT2 two-point teaching OUT1 OUT2 kPa Torr Psi kPa Torr Psi OUT2 one-point teaching OUT1 OUT2kPa Torr Psi t.h1: Teach hysteresis mode at first point t.w: Teach window mode Two-point Teaching (Hysteresis-mode Teaching) Present measurement value is displayed. Present measurement value is displayed. OUT1 OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi 1. Press the SET key under condition 1 below while t.h1 is displayed to display the present measurement value. 2. Check the measurement value and press the Set key to perform and complete teaching the first point. 3. Press the Set key under condition 2 below to display the present measurement value. (This list of steps continues on the next page.) 14 E8F2 E8F2 Output Two-point Teaching ON ON point: (TEACH1 + TEACH2)/2 OFF point: ON point -- 3% FS (default value) the default value is changeable. Condition 2 Condition 1 OFF Pressure value OFF point ON point Entered OUT1 OUT2 kPa Torr Psi TEACH1 and TEACH2 can be performed in reverse order. TEACH1 value can be larger than TEACH2 value or vice versa. or Measurement mode Not entered 4. Check the measurement value and press the Set key to perform and complete teaching the second point. 5. Press the SET key for approximately 2 s while t.h1 is displayed to enter the values and return the E8F2 to measurement mode. 6. Press the Up and Down keys simultaneously to set the E8F2 to measurement mode without selecting the values. Note: The E8F2 will be automatically set to hysteresis mode by performing two-point teaching. Two-point teaching is ideal for applications that check for vacuum attachment. Auto-teaching • One-point Teaching (Window-mode Teaching) OUT1 Present value OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Entered OUT1 OUT2 kPa Torr Psi or Measurement mode Not entered 1. Press the SET key under condition 3 below while t.w is displayed to display the present measurement value. One-Point Teaching Output Condition 3 ON point: TEACH1 -- 30% FS OFF point: TEACH1 + 30% FS The default value is 10% FS (changeable). ON OFF ON point OFF point Pressure value 2. Check the measurement value and press the Set key to perform and complete teaching. 3. The values are entered Press the SET key for approximately 2 s while t.w is displayed to enter the values and return the E8F2 to measurement mode. 4. Press the Up and Down keys simultaneously to return the E8F2 to measurement mode without selecting the values. Note: The E8F2 will be automatically set to window mode by performing one-point teaching. One-point teaching is ideal for applications that check original pressure. 15 E8F2 E8F2 Teaching Error • Present value not within set range Error display for 1 s OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Meaning of display: er.t (Error teach) If the present value or the result of calculation after teaching is not within the range, the SET key input will not be accepted. In this case an error will be displayed for 1 s if teaching is performed. Special Setting Mode Key-protect, hysteresis width, window width, display refresh interval, number of measurement times for averaging, and bar indicator range settings are set in special setting mode. Setting item Measurement mode OUT1 OUT2 kPa Torr Psi Setting item Hysteresis width key-protect OUT1 OUT2 OUT1 OUT2 kPa Torr Psi Window width kPa Torr Psi OUT1 OUT2 Display refresh interval kPa Torr Psi OUT1 OUT2 Number of measurement times for averaging kPa Torr Psi Bar indicator range OUT1 OUT2 kPa Torr Psi 1. Press the SET key and Up key simultaneously to set the E8F2 to special setting mode and display prt. 2. Set the Up or Down key to select the items prt, hys, wid, dsp, aUe, and bar. Key-protect Setting No key-protect OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi or Press the Up or Down key to change the set value. Key-protect Status 0: No Key-Protect. 1: No basic or pressure settings are accepted. 2: No input is accepted other than for checking the pressure value or special settings or setting to energy-saving mode. 1. 2. 3. 4. Press the SET key while prt is displayed to display the key-protect value presently set. Press the Up or Down key to change the value. Press the SET key to select the displayed value and display prt again. Press the Up and Down keys simultaneously display prt again without selecting the value. 16 OUT1 OUT2 kPa Torr Psi E8F2 E8F2 Hysteresis Width Setting The hysteresis width can be changed by taking the following steps. Hysteresis mode Output or OUT1 OUT2 kPa Torr Psi ON Change in hysteresis width desired OFF OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Window mode Output Press the Up or Down Key to change the set value. ON Change in hysteresis width desired OFF ON point 1. 2. 3. 4. 5. 6. Pressure value OFF ON point point OFF point Pressure value Press the SET key while hys is displayed to display the hysteresis width of OUT1 presently set. Press the Up or Down key to change the set value within a range between 0 and 10.0% FS. Press the SET key to select the displayed set value and display the hysteresis width of OUT2 presently set. Press the Up or Down key to change the set value. Press the SET key to select the displayed set value and display hys again. Press the Up and Down keys simultaneously to display hys again without selecting the value. Note: 1. Hysteresis Mode: No manual hysteresis width settings are enabled in hysteresis mode except for those set by auto-teaching. Window Mode Hysteresis width settings are enabled when the E8F2 in window mode is set to measurement mode. 2. ON- and OFF-point widths in hysteresis mode are used as hysteresis widths, which cannot be changed in window mode. Window Range Setting or OUT2 Output OUT1 OUT1 OUT2 kPa Torr Psi OUT1 OUT2 OUT1 OUT2 kPa Torr Psi kPa Torr Psi ON (0 to 30%) OFF Reference value (TEACH1) Press Up or Down key to change set value. 1. 2. 3. 4. 5. 6. Press the SET key while wid is displayed to display the window width of OUT1 presently set. Press the Up or Down key to change the set value within a range between 0 and 30% FS of the reference value. Press the SET key to select the displayed set value and display the window width of OUT2 presently set. Press the Up or Down key to change the set value. Press the SET key to select the displayed set value and display wid again. Press the Up and Down keys simultaneously to display wid again without selecting the set value. Note: No window width settings will be enabled in hysteresis mode. 17 Pressure value E8F2 E8F2 Display Refresh Interval Setting • The following refresh intervals are selectable. 0.1: The average value is displayed at 0.1-s intervals. 0.5: The average value is displayed at 0.5-s intervals. 1.0: The average value is displayed at 1.0-s intervals. OUT1 OUT2 OUT1 OUT2 kPa Torr Psi kPa Torr Psi or Press Up or Down key to change set value. 1. Press the SET key while dsp is displayed to display the display refresh interval presently set. 2. Press the Up or Down key to change the set value. 3. Press the SET key to select the displayed set value and display dsp again. 4. Press the Up and Down keys simultaneously to display dsp again without selecting the set value. Note: Set the AVE to the number of measurements for obtaining an average value. Measurement Value Averaging Time Setting The number of measurements can be set to 1, 8, 32, or 256. OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi or Press Up or Down Key to change set value. 1. Press the SET key while aUe is displayed to display the set value as the number of measurements for averaging measured values. 2. Press the Up or Down key to change the set value. 3. Press the SET key to select the displayed set value and display aUe again. 4. Press the Up and Down keys simultaneously to display aUe again without selecting the set value. Note: If the DSP item is set to 0.5 and AVE item is set to 32, the E8F2 will measure 32 times, the average value of which will be treated as one block. The average block value for 0.5 s will be displayed at 0.5-s intervals. 18 E8F2 E8F2 Bar Indicator Range Setting The set value is an indication range per LED between 1 and 20% FS. If the E8F2 is set to AUT, the ideal display range will be automatica set according to the the ON point presently set. OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi or Press Up or Down key to change set value. 1. Press the SET key while bar is displayed to display the bar display range presently set. 2. Press the Up or Down key to change the set value. 3. Press the SET key to select the displayed set value and display bar again. 4. Press the Up and Down keys simultaneously to display bar again without selecting the set value. Note: The bar indicator range will be available to OUT1 output and will be enabled in hysteresis mode only. Bar Indicator The user can visually sense the measured pressure according to the ON and OFF points from the bar indicator. This indicator is available to OUT1 output only. There is a difference in indication mode between hysteresis mode and window mode. • Hysteresis Mode The five LEDs indicate the present pressure provided that the ON point is between the second and third LEDs from the left. Output 1-MPa Model (with 300 kPa as ON Point) ON Condition 1 (350 kPa) OFF Pressure value: kPa 300 (ON point) The indication range per LED is obtained from the following. • 300 kPa ≤ 1 MPa x 1/2 • 300 kPa x 1/3 = 100 kPa The first through third LEDs from the left are all ON under condition 1. The indication range per LED is the set value of the indication range in special setting mode. If the set value is aut, the following ranges are obtainable. When ON point ≤ Rated pressure x 1/2 Indication range per LED = ON point x 1/3 When ON point > Rated pressure x 1/2 Indication range per LED = (Rated value -- ON point) x 1/3 Window Mode The distance between ON and OFF points are divided into five equal portions. The present pressure will be indicated by a single LED that will be ON. The left LED will flash if the present pressure is below the ON point and the right LED will flash if the present pressure is above the OFF point. • Output 1-MPa Model (with 300 kPa as ON point and 600 kPa as OFF point) ON Condition 2 (450 kPa) OFF 300 kPa (ON point) Condition 3 (700 kPa) 600 kPa (OFF point) Pressure value: kPa Only LED (a) will be lit under condition 2. Only LED (b) will be lit under condition 3. The display range per LED will be the following. Difference between ON and OFF points x 1/5 Note: No bar indicator settings in special setting mode will be enabled 19 E8F2 E8F2 Returning to Measurement Mode Key-protect Setting items or OUT1 OUT2 kPa Torr Psi or OUT1 OUT2 kPa Torr Psi or OUT1 OUT2 Number of measurement times for averaging Display refresh interval Window width Hysteresis width kPa Torr Psi or OUT1 OUT2 kPa Torr Psi Entered Entering Set Values: Press the SET key for approximately 2 s while the value is displayed. Not entered Bar indicator range setting or OUT1 OUT2 Measurement mode OUT1 OUT2 kPa Torr Psi kPa Torr Psi Not Entering Set Values: Press the Up and Down keys simultaneously while the value is displayed. Energy-saving Mode The E8F2 has functions to save power by turning OFF the numeric and menu display and leaving the bar indicator turned ON. Energy-saving Function 1 Normal Measurement Mode OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi 1. The numeric and menu display is turned OFF by pressing the SET and Down keys simultaneously in measurement mode. 2. The display is turned ON by pressing the SET and Down keys simultaneously again. Energy-saving Function 2 If the present pressure is not within the set range, the numeric and menu display will flash as a warning. Pressure beyond the set range is imposed. OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi OUT1 OUT2 kPa Torr Psi Pressure value flashes. Displayed for 1 s 1. If the SET and Down keys are pressed simultaneously for approximately 3 s in measurement mode, eco will be displayed for 1 s and then the numeric and menu display will be turned OFF. 2. Provided that the E8F2 is set to window mode, the numeric and menu display will flash together with the bar indicator if the present pressure is below ON point or above the OFF point. 3. The numeric and menu display and the bar indicator return to normal condition by pressing the SET and Down keys simultaneously. 20 E8F2 E8F2 ON- and OFF Set Value Check Function ON- and OFF-point Set value or Measurement mode or or or or Displayed alternately Displayed alternately OUT1 ON point Displayed alternately Displayed alternately OUT2 OFF point OUT2 ON point OUT1 OFF point The ON and OFF points presently set can be checked. Press the Up or Down Key in measurement mode to display the OUT1 ON point and on alternately. Press the Up or Down Key again to display the OUT1 OFF point and off alternately. Press the Up or Down Key after the above to display the OUT2 items. If no key is input for approximately 2 s during the above operation, the present measurement value will be displayed automatically. Dimensions Unit: mm (inch) J CONTROLLER E8F2 Display panel 28 (1.10) 27 (1.06) 29 (1.14) 25.5 (1.00) 1.5 (0.06) 2 (0.68) 17 (0.67) 9 8 (0.35) (0.31) Pressure-introducing Two-M3 (Depth: 6) section 1/8 NPT 28 (1.10) 20 (0.79) 27 (1.06) Vinyl-insulated round cable with five conductors, 4 dia. (0.08 dia. x 30); standard length: 2 m 20.5 (0.81) 20 (0.79) 6 (0.24) Mounting Dimensions With Mounting Bracket Two-M3 20.5 (0.81) 29 (1.14) 27 (1.06) 15 (0.59) 5.4 (0.21) 20 (0.79) 20 (0.79) 42 (1.65) 28 (1.10) 15 (0.59) 21 E8F2 E8F2 J ACCESSORIES E89-F3 Mounting Bracket 15 ±0.4 (0.59) 20.5 (0.81) 9 (0.35) Two-3.5 (0.14) dia. 27 (1.06) 20 (0.79) 14.5 (0.57) Four-R1 (R0.04) 13.5 (0.53) 20 (0.79) 26.9 (1.06) * Provided with E8F2 Two-3.5 (0.14) dia. 4.5 (0.18) R1.6 (R0.06) R7.25 (R0.29) Four-R2.5 (R0.10) 1.6 (0.06) J E89-F4 PANEL-MOUNTING BRACKET (SOLD SEPARATELY) Panel Cutout Dimensions (E89-F4 is available in the following two sizes.) 20.65 (0.81) Spacer not mounted 0 0 0 (1.42+0.02) (1.30+0.02) 4 (0.16) (1.42+0.02) 36+0.5 0 40 (1.57) 36+0.5 0 (1.30+0.02) 0 33+0.5 Panel Spacer mounted 33+0.5 12.15 (0.48) 0 0 Panel 25 (0.98) 17 (0.67) 41.3 (1.63) Note: The spacer can be removed from the panelmounting bracket. The panel cutout dimensions can be adjusted as shown above by attaching or detaching the spacer. 40 (1.57) 11.5 (0.45) 20 (0.79) Spacer 22 E8F2 E8F2 Precautions J ENVIRONMENT • • • J MOUNTING Do not use the Sensor in locations subject to explosive or flammable gases. Do not use the Sensor in an environment subject to corrosive or combustible gases. Make sure that the Sensor is free of water. J AVOID DAMAGE TO THE E8F2 • • • • • • • Do not impose any voltage exceeding the rated voltage on the E8F2. Do not short-circuit the load connected to the E8F2. When supplying power to the E8F2, make sure that the polarity of the power is correct. • • J WIRING • • Do not wire power lines or high-tension lines adjacent to the lines of the E8F2. If no linear output is used, cut the gray lead wire short and apply insulating tape to the lead wire so that it will not come into contact with any other terminal. • Mount the Sensor so that ultrasonic vibrations will not be applied directly to the Sensor. Do not insert any wire into the pressure port. Doing so may damage the pressure elements and cause a malfunction. Do not apply a tensile strength in excess of 50 N (11.25 lbs) to the cords or connectors. The pressure-introducing section (aluminum die-cast made) is fixed with tapered 1/8 NPT male screws and M5 female screws. When using tapered screws, use tapered 1/8 NPT female screws. Wrap the tapered 1/8 NPT male screws with sealing tape to prevent any leakage. Tighten the male screws to a torque of 10 NSm (7.38 ftSlbs) max. Tighten M5 female screws to a torque of 2 NSm (1.48 ftSlbs) max. Tightening each male screw by using a 12-mm wrench to hold its hexagonal head, not the screw itself. E8F2 Hexagonal head • When attaching the Mounting Bracket to the Sensor, make sure that each M3 screw is tightened to a torque of 0.5 NSm (0.37 ftSlbs) max. NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A.
E8F2D10C 价格&库存

很抱歉,暂时无法提供与“E8F2D10C”相匹配的价格&库存,您可以联系我们找货

免费人工找货