0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ERT1MD32SLH1

ERT1MD32SLH1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Ethernet/IP Remote I/O Unit

  • 数据手册
  • 价格&库存
ERT1MD32SLH1 数据手册
EtherNet/IP Remote I/O Blocks, Cage Clamp Connectors ERT1-††32SLH-1 High Density EtherNet/IP Remote I/O with Short and Open Circuit Detection „ „ Simple & Fast Wiring – Cage clamp terminals allow for easy & fast wiring saving setup time 3 Wire Termination – for cleaner wiring and easier debugging „ Cage Clamp Connections – for vibration resistant wiring. „ High Density Wiring – small footprint saves panel space; 32 I/O, 24VDC, PNP--32 inputs, 32 outputs, or 16in/16out versions. „ Tag Data Links – Multi vendor communications using CIP messaging makes it easy to talk to Omron and third-party masters. „ Auto Baud Rate – simplifies installation, automatically detects the baud rate of a connected switch. „ Node address can be set by rotary switches – for fast maintenance, easy swap out. „ Quick to service: Removable cage clamp wiring blocks for fast replacement and less downtime. „ Power connector is removable and so is the Ethernet cable -for fast maintenance. „ „ Status and Error LEDs for each input/output - for fast troubleshooting. EtherNet/IP conformance tested – for interoperability with devices from other brands. Diagnostics that Pinpoint Wiring Shorts and Sensor Errors in Seconds Not Hours The ERT1 I/O Block detects shorts at the sensor and prevents the short from affecting the rest of the inputs. It also has LEDs to tell you which input or output is shorted. It also has I/O bits back to the master telling you if an input or output is shorted or open (broken sensor or broken wire to sensor). Each group of 16 I/O has its own power terminals and the communications module has its own power terminals. This way the module can also tell you if power to the I/O terminals is lost. The LEDs are yellow for on, red for shorted, red flashing for disconnected, and off for off. The short and open circuit detection can be enabled or disabled for each input/output. International Approvals CE, cULus Class I, Division 2, Groups A, B, C and D; IP20 rating for mounting inside an enclosure. System Configuration Ordering Information EtherNet/IP Remote I/O Units Inputs 32 -16 Outputs -32 16 I/O type PNP PNP PNP Output current -0.5A/point 4.0 A/common 0.5A/point 4.0 A/common Input current 6mA at 24VDC max. -- Model ERT1-ID32SLH-1 ERT1-OD32SLH-1 6mA at 24VDC max. ERT1-MD32SLH-1 Slave I/O Block Compatibility with Omron Controllers PLC Type CJ2M-CPU3† CJ2H-CPU6†-EIP CJ1, NSJ with CJ1W-EIP21 CS1 with CS1W-EIP21 NJ501-1†00 CP1E CP1L CP1H ERT1-ID32SLH-1 Yes Yes Yes Yes Yes No No No ERT1-OD32SLH-1 Yes Yes Yes Yes Yes No No No ERT1-MD32SLH-1 Yes Yes Yes Yes Yes No No No Notes: 1) All units require a 24 VDC power supply for power and 24VDC power for each bank of 16 I/O. 2) Minimum current for disconnection detection is 0.2mA. 3) Maximum current for short circuit detection is 50mA/point min. 4) Shorting of one input or output does not affect the rest of the inputs or outputs. 5) Short circuit and disconnection detection can be turned on for each I/O independently. 2 Status Areas Generic Status Area Generic Status Area which is Tag Set Input_100. The Digital I/O Slave Unit's Generic Status Area contains the following 16 bits. Bit 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Content I/O Power Supply Status Flag 1 OFF: I/O power is ON ON: I/O power is not ON I/O Power Supply Status Flag 2 OFF: I/O power is ON ON: I/O power is not ON Reserved Reserved Power or Load short-circuit detection flag: OFF: Normal ON: Short-circuit Disconnection flag; OFF: Connected ON: Disconnected Reserved Reserved EEPROM data error flag: OFF: Normal ON: Error occurred Reserved Reserved Reserved Reserved Reserved Reserved Reserved Description Turns ON when I/O power is not being supplied to terminal block 1. Turns ON when I/O power is not being supplied to terminal block 2. ----Turns ON when there is a short in the power supply or load connection to the connected devices, including wiring mistakes and connected device failure. Turns ON when the sensor power supply is not connected or the load is disconnected due to a wiring error, failure in the connected device, etc. ----Turns ON when there is an error in the EEPROM data. --------------- I/O Status Area I/O Status Area which is Tag Set Input_135. The I/O Status Area for a Digital I/O Slave Unit consists of the following 8 bytes (64 bits). The I/O Status Area indicates the short-circuit and disconnection error status for each terminal. Byte offset 0 1 2 3 4 5 6 7 Data Bit 07 06 05 04 03 02 Power or Load Short-circuit Detection Flags for Terminal Block 1 07 06 05 04 03 02 Power or Load Short-circuit Detection Flags for Terminal Block 1 15 14 13 12 11 10 Power or Load Short-circuit Detection Flags for Terminal Block 2 07 06 05 04 03 02 Power or Load Short-circuit Detection Flags for Terminal Block 2 15 14 13 12 11 10 Disconnection Flags for Terminal Block 1 07 06 05 04 03 02 Disconnection Flags for Terminal Block 1 15 14 13 12 11 10 Disconnection Flags for Terminal Block 2 07 06 05 04 03 02 Disconnection Flags for Terminal Block 2 15 14 13 12 11 10 3 01 00 01 00 09 08 01 00 09 08 01 00 09 08 01 00 09 08 32 input module - ERT1-ID32SLH-1 There are 32 inputs which are input Tag Set Input_6. 32 output module - ERT1-OD32SLH-1 There are 32 outputs which are input Tag Set Output_36 16 input and 16 output module - ERT1-MD32SLH-1 There are 16 inputs which are input Tag Set Input_5. There are 16 outputs which are output Tag Set Output_35. Note: All of the open and short-circuit status bits are mapped in one of the I/O maps which allows the user to monitor I/O and status bits using polled I/O instead of having to use explicit messages. This makes getting diagnostic data much easier. Specifications Input Specifications Item Input points Internal I/O common ON voltage OFF voltage OFF current Input current ON delay time OFF delay time Number of circuits Isolation method Input indicators Power supply short-circuit Disconnection detection Connections forms Specifications 16 points PNP 15 V DC min. (between each input terminal and 0 V) 5 V DC max. (between each input terminal and 0 V) 1.0 mA max. 6.0 mA max. at 24 V DC 3.0 mA max. at 17 V DC 1.5 ms max. 1.5 ms max. 16 points with one common circuit Photocoupler isolation LEDs (yellow) Operates at 50 mA/point min. Operates at 0.2 mA/point max. Screw-less clamp terminal blocks (orange) Output Specifications Item Output points Internal I/O common Output current Residual voltage Leakage current ON delay OFF delay Number of circuits per common Isolation method Output indicators Power supply short-circuit protection Disconnection detection Connection forms Specification 16 points PNP 0.5 A/point, 4.0 A/common 1.2 V max. (0.5 A DC, between each output terminal and the V terminal) 0.3 mA max. (24 V DC, between each output terminal and V terminal) 0.5 ms max. 1.5 ms max. 16 outputs/common Photocoupler LEDs (yellow) Operates when output current is exceeded. Operates at current consumption of 3 mA/point max. (Not detected at 3 mA or less.) Screw-less clamp terminal blocks (yellow) Common Specifications Item Current consumption Mounting Weight Standard accessories Specifications Communications power supply (including internal circuits): 110 mA max. 35 mm DIN track mounting 485 g max. Connector with lock screws FKMCP1.52STF3.5AUSOO (Phoenix Contact) 4 Component Names and Functions (1) Rotary Switches These switches are used to set the node address. (2) Ethernet Connector The network communications cable is connected to this connector. (3) Power Supply Connector The communications and Unit power supply is connected to this connector. Applicable Ferrules Manufacturer Phoenix Contact Nihon Weidmuller Model AI-0.5-10 H 0.5/16 D Applicable wire size 0.5 mm2 (AWG 20) 0.5 mm2 (AWG 20) (4) Communications Indicators: MS and NS These indicators show the Unit communications status and network communications status. (5) and (6) Terminal Blocks 1 and 2 The I/O devices and output power supply are connected to these terminal blocks. (7) and (8) I/O Indicators These indicators show the ON/OFF status of the I/O and the error status of connected devices. 5 Internal Circuits Inputs Outputs 6 Wiring Inputs Outputs 7 Common Specifications Dimensions ERT1-ID32SLH-1, ERT1-OD32SLH-1, ERT1-MD32SLH-1 Unit: mm Indicators I/O Indicators The meanings of the input indicators are given in the following table. Setting the Node Address The rotary switches are used to set the lower digits of the IP address. Rotary Switch Settings 00 hex: BOOTP or tool setting enabled (factory setting) 01 to FE hex: Setting on rotary switches is lower 8 bits of IP address. (Default setting of upper 24 bits: 192.168.250.) FF hex: Restores default setting. (To restore the default setting, set the switches to FF hex, cycle the power supply, and then set the switches to 00 hex.) 8 Features Functions Common to All Slave Units This section describes the functions common to all EtherNet/IP Slave Units and the procedures for using them. Automatic Baud Rate Detection The EtherNet/IP Slave Units are automatically set to the same baud rate as the hub. It is not necessary to set the baud rate separately for any Slave Unit. The baud rate is set when communications is established with the hub after the power is turned ON. The baud rate setting is stored in memory until the power is turned ON again or until the Master Unit baud rate setting is changed. Hold/Clear Outputs Output Units can be set to hold or clear outputs when an error occurs. Procedure Using Network Configurator 1. Turn ON the power to the EtherNet/IP Slave Unit. 2. Double-click the icon of the Slave Unit to set in the Network Edit Device Parameters Window to open the Configuration Window. (Alternatively, rightclick the icon and select Parameters - Edit from the pop-up menu.) 3. The fault action (holding or clearing an output for a communications error) will be displayed for each output in the Fault Action Setting Group. Select Hold Last State or Clear Data for the terminals and then click the OK Button. Clear Hold Clears all output data from the Master Unit to 0 when a communications error occurs. Holds all output data from the Master Unit at its current status when a communications error occurs. 9 I/O Power Status Monitor Outputs can be set to be held or cleared when an error occurs in the Output Unit. To check the status, refer to bits 0 and 1 in the Generic Status Area. Input Filter (Input Units Only) An input value is read more than once during a set time interval. The input value can be set to be enabled only when all the read values are the same. This function operates for all input points in one Slave Unit. The following settings are possible: No delay (no filter), or 4, 8, 16, 32, 64, 128, or 256 ms. OFF-ON Delay When the input data turns ON, the input data is read 4 times at a set time (1/4 of the time setting). The internal input data turns ON only when all four values are ON. The ON timing is delayed by the value of the input time constant. ON-OFF Delay When the input data turns OFF, the input data is read 5 times at a set interval (1/5 of the OFF response time setting). The internal input data turns OFF only when all values are OFF. The OFF timing is delayed by the value of the OFF response time. This function can also be used to implement an OFF delay. To enable reading pulses shorter than the communications cycle time, set the OFF response time to a value longer than the communications cycle time. (The input may remain ON if the input pulse interval is too short.) 10 Settings Using the Network Configurator 1. Turn ON the power supply to the EtherNet/IP Slave Unit. 2. Double-click the icon of the Slave Unit to set in the Network Configuration Window to open the Edit Device Parameters Window. (Alternatively, rightclick the icon and select Parameters - Edit from the pop-up menu.) 3. Select an input in the Input Point Group Setting Group and set the Off-On Delay or On-Off delay from the pull-down menu. Power Short-circuit Detection (Input) This function monitors the sensor power supply current. If the current is 50 mA or higher per input contact, a power short-circuit is detected. The Slave Unit I/O indicator can be used to check whether a power short-circuit has been detected. When a power short-circuit is detected, a flag in a status area in the Slave Unit turns ON to notify the Master Unit. The notification details can be read using explicit messages. When the cause of the short-circuit is removed, the Slave Unit is automatically reset, and the power output to the connector that had the short-circuit is turned ON again. 11 Load Short-circuit Detection (Output) This function monitors the load current for the output section and detects an load short-circuit if the current per contact (or common) exceeds a specific value. When a load short-circuit is detected, all Unit outputs are turned OFF to prevent damage to the Unit's output circuits. The I/O power for the Unit turns OFF if a short-circuit is detected for even just one of the contacts being used. When a load short-circuit is detected, a flag in a status area in the Slave Unit turns ON to notify the Master Unit. When the cause of the short-circuit is removed, the Slave Unit is automatically reset, and the power output to the connector for which the short-circuit was detected is turned ON again. Related Products Software CX-One version 4 contains the Network Configurator for EtherNet/IP. CXONE-AL01C-V4 is the part number for a single license copy on CD. Ethernet Switch Options The following network devices are manufactured by OMRON for EtherNet/IP networks. Function Number of Ports Packet priority control (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm, LSI error detection, 10/100Base-TX, AutoNegotiation 3 5 5 Error detection output None None Provided Model W4S1-03B W4S1-05B W4S1-05C Ethernet Cables Description Double-ended EtherCAT Cable with Straight Connectors Connector type RJ45/RJ45 on both ends Cable length L 0.3 m 0.5 m 1m 2m 3m 5m 10 m 15 m Model XS5W-T421-AMD-K XS5W-T421-BMD-K XS5W-T421-CMD-K XS5W-T421-DMD-K XS5W-T421-EMD-K XS5W-T421-GMD-K XS5W-T421-JMD-K XS5W-T421-KMD-K Manuals Description ERT1 Series EtherNet/IP Slave Units Operation Manual XS5 SmartClick Sensor I/O Connectors Data Sheet 12 Media PDF PDF Publication number W481-E1-02 G016-E1-02 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br Omron Europe B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • Tel: +31 (0) 23 568 13 00 • Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu Authorized Distributor: Automation Systems • Programmable logic controllers (PLC) • Human machine interfaces (HMI) • Remote I/O • Industrial PC’s • Software Motion & Drives • Motion controllers • Servo systems • AC drives Control Components • Temperature controllers • Power supplies • Timers • Counters • Programmable relays • Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays • Limit switches • Pushbutton switches • Low voltage switch gear Sensing & Safety • Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors • Cable connectors • Displacement & width-measuring sensors • Vision systems • Safety networks • Safety sensors • Safety units/relay units • Safety door/guard lock switches R34I-E-01 08/11 Note: Specifications are subject to change. Printed on recycled paper. © 2011 Omron Electronics LLC Printed in U.S.A.
ERT1MD32SLH1 价格&库存

很抱歉,暂时无法提供与“ERT1MD32SLH1”相匹配的价格&库存,您可以联系我们找货

免费人工找货