0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
F03-16PE-5M

F03-16PE-5M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    SENSING BAND LIQUID LEAKS 5M

  • 数据手册
  • 价格&库存
F03-16PE-5M 数据手册
Sensing Band F03-16PE CSM_F03-16PE_DS_E_1_7 • SUS316 used for core and polyethylene used for sheath to ensure high resistance to both acidic and alkaline liquids. • Sensing Band Stickers that use the same material as the Sensing Band’s insulating resin are available in 2 types: adhesivetape type and screw type. Indicates models that allow free cutting. Ordering Information Name Liquid Leakage Sensing Band Model 1m F03-16PE 1M 2m F03-16PE 2M 5m F03-16PE 5M 10 m F03-16PE 10M 15 m F03-16PE 15M 20 m F03-16PE 20M 25 m F03-16PE 25M 30 m F03-16PE 30M 40 m F03-16PE 40M 50 m F03-16PE 50M 100 m F03-16PE 100M Sensing Band Stickers (adhesive tape) F03-26PES * Sensing Band Stickers (screw) F03-26PEN * Note: 1. Specify the cable length for F03-16PE from the list above. 2. The cables can be cut. * 30 Stickers per set Specifications Sheath Polyethylene Core SUS316 stainless steel Ambient operating temperature −10 to 55°C Weight Approx. 16 g (1 m) 1 F03-16PE Dimensions (Unit: mm) ■ Sensing Band Appearance Structure 4 20 1.2 1.7 8 Materials: Electrodes: SUS316 stainless steel, Sheath: Polyethylene ■ Sensing Band Stickers F03-26PEN (screws) F03-26PES (adhesive tape) Appearance Structure 22 5 5 19.2 32 5 6.5 1.0 3.0 6.5 12 Cut section Two, 3.5 dia. Adhesive tape (See note.) Material: Polyethylene Material: Polyethylene Note: The shape of the adhesive tape shown above is for securing the F03-16PE. Chemical Resistivity for F03-16PE/-16PT Material Sheath Polyethylene Fluoroplastic Core Material SUS316 Sheath Polyethylene Fluoroplastic Core SUS316 Water A A A Toluene C B B Acetone C A A Phenol B B A Ammonia A A A Butanol B A --- Ethanol B A A Fluorine A A C Hydrochloric acid A A C Hexane C A --- Hydrogen peroxide solution A A A Benzene C A A Xylene B A A Methanol B A A Cyclohexane C A --- Sulfuric acid C A B Trichloroethylene C A A Phosphoric acid A B B Note: 1. A: Not affected at all or only very slightly affected. B: Slightly affected but, depending on the conditions, sufficient for use. C: Affected but may still be used. (Replace the Sensing Band immediately after detection.) 2. The F03-16PE Sensing Band is made from the following materials. Core: SUS316 Insulated sheath: Polyethylene 3. In order to prevent secondary fire damage, consider the effect of the atmosphere of the environment and the solution to be detected on the Sensing Band. 4. If the Sensing Band changes shape or color when a liquid is detected, replace the Sensing Band. 2 F03-16PE Connecting the Sensing Band Bending the Sensing Band Interval Between Stickers To change the direction of the Sensing Band, bend the Sensing Band in one or two places where the core is not exposed. When securing the Sensing Band with Stickers, attach the Stickers at intervals of 20 to 30 cm in places where the core is not exposed. 20 to 30 cm Bent in 1 place Bent in 2 places Note: Bend the Sensing Band approximately 4 cm (i.e., twice the distance between places where the core is exposed) away from places where a Sticker is attached. If the Sensing Band is bent at places further away than this, the Sensing Band may come away from the surface. Stripping and Connecting Terminals 1. Cut into the Sensing Band approximately 4 to 6 cm in from the end as shown in the diagram below. 2. Strip away approximately the last 9 mm of the sheath to expose the core (SUS line). 3. To connect to the Terminal Block, insert the screwdriver (see note 3) from the top of the Terminal Block and insert the stripped end of the core from the side. (Refer to Dimensions on page 2.) Sensing Band Sticker Note: 1. When using the F03-26PES (adhesive-tape model), be sure to wipe all moisture, oil, and dust from the surface to which the Sticker is to be attached. Failure to do so may result in insufficient adhesion, and the Sticker may peel away from the surface. 2. When using the F03-26PEN (screw model), before installing the Sensing Band, it is necessary to perform stud welding. For details on the pitch of the studs, refer to the information on the dimensions of Sensing Band Stickers. 3. Commercially available screwdrivers can be used. It is recommended, however, that either a 210-350/01 screwdriver or a 209-132 operating tool to connect jumpers, both manufactured by Wago Japan, is used. Contact http://www.wago.com. Insert 4 to 6 cm 9 mm Exposed part of core F03-20 Terminal Block Note: Check that the wiring is secure before using the K7L in applications. 3 F03-16PE FAQs Some questions that are frequently asked about the K7L are given below. Use this information when selecting a model. Can one K7L Amplifier be used for detection in more than one place? Yes. By using Terminal Blocks to connect Sensing Bands in parallel, detection can be performed in more than place with only one K7L Amplifier. Total: 400 m max. Can a different terminal block (e.g. a commercially available terminal block or a terminal block constructed by the user) be used instead of the one provided? Yes. When using another terminal block, however, be sure to check that all the terminals are mutually isolated, and that there is no danger of ground faults in connecting cables or Sensing Bands. Terminal TerminalBlocks Block K7L-U Can the K7L Amplifier detect pure water? Yes. Note: 1. When wiring, be sure not to exceed the maximum possible wiring distances for both the connecting cable and the Sensing Band. Exceeding these distances may lead to faulty operation. Connect one Sensing Band to each Terminal Block. 2. Not applicable to the K7L-UD. Even pure water, which has a resistance exceeding 10 MΩ⋅cm, can nearly always be detected if the K7L is used at its maximum sensitivity. This is because impurities are mixed with the water when it is leaked and the resistance drops. Pure water Impurities in the air Can the K7L Amplifier be used as a replacement for the 61F-GPN-V50 Water Leakage Detector? Can the K7L Amplifier detect oil? Yes. Because the surge withstand capability is different, however, do not use in locations where it will be exposed to impulses and surges, such as outdoor roofs or in pump panels. Also, items such as the power supply voltage and the connection sockets are different. Check these items before application. No. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 4 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2020.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2020 All Right Reserved.
F03-16PE-5M 价格&库存

很抱歉,暂时无法提供与“F03-16PE-5M”相匹配的价格&库存,您可以联系我们找货

免费人工找货