0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
F03-16PS

F03-16PS

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    F03-16PS - Liquid Leakage Point Sensor - Omron Electronics LLC

  • 数据手册
  • 价格&库存
F03-16PS 数据手册
Liquid Leakage Point Sensor F03-16PS CSM_F03-16PS_DS_E_2_2 A New Liquid Leakage Point Sensor Has Been Added to the K7L Series. Fluoroplastic Coating on the Bottom Electrode Ensures Chemical Resistance. • • • • Can be used in conjunction with Sensing Bands. Stud screw mounting requires no tools for installation. No tools means the Sensor can be wiped clean quickly and easily. The optional Mounting Bracket enables faster installation than three-screw mounting. • Connect multiple Sensors to one K7L Amplifier for significant cost savings. Indicates models that allow free cutting. Ordering Information Sensors Product name Liquid Leakage Point Sensor Mounting Brackets (See note 1.) Terminal Block (See note 2.) Nylon 6.6 Main material Polyethylene Cable material Outer sheath: PVC Inner sheath: Fluoroplastic ----SUS304 SUS304 and fluoroplastic coating ----Electrode material Model F03-16PS F03-16PS-F F03-26PS F03-20 Note: 1. Use a commercially available bonding agent for PVC. One bag contains 10 Brackets. 2. One bag contains 10 Blocks. Amplifier Product name Liquid Leakage Sensor Amplifier K7L-U Model Specifications Material Sensor Amplifier Conductor Core Ambient operating temperature range Weight Maximum number of Point Sensors connected per Amplifier Applicable Amplifier Polyethylene Outer sheath: PVC, Inner sheath: Fluorine resin F03-16PS: SUS304 stainless steel F03-16PS-F: SUS304 and fluorine coating −10 to 60°C Approx. 30 g Any number up to an overall cable length of 400 m. K7L-U (excluding Liquid Leakage Sensor Amplifier with disconnection detection function) Wiring Diagram Any number of Sensors can be connected in parallel up to an overall cable length of 400 m. Leakage areas cannot be specified with the K7L. 5 6 7 8 4 3 2 1 4 3 2 4 3 2 4 3 2 4 3 2 F03-16PS Liquid Leakage Point Sensor K7L-U Liquid Leakage Sensor Amplifier Sensing Band F03-20 Terminal Block Overall cable length: 400 m max. 4 3 2 4 3 2 F03-16PS Liquid Leakage Point Sensor Mounting Methods Stud Screw Mounting Securing the Sensor with a Nut Securing the Sensor with a Wing Nut Special Bracket Mounting (See note.) Note: Use a commercially available bonding agent for PVC. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 1 Read and Understand This Catal og Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Li abilit y WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.1 In the i nter est of product improvement, specifications are subject t o change without notice. Indust rial Automat ion Company http://www.i a.omron.com/ OMRON Corporation (c)Copyright OMRON Corporation 2009 All Right Reserved.
F03-16PS 价格&库存

很抱歉,暂时无法提供与“F03-16PS”相匹配的价格&库存,您可以联系我们找货

免费人工找货