Pattern Matching Sensor
F10
Ordering Information
Heads
Item
Setting distance
Detection range
Model
Red LED (wide field of vision)
100±10 mm
25 ´ 20 mm
F10-S30R
Green LED (medium field of vision)
50±5 mm
12 ´ 10 mm
F10-S15R
Green LED (narrow field of vision)
(available soon)
33±3 mm
4.5 ´ 3.5 mm
F10-S05R
Amplifiers
Type
Standard models
Output
No. of registered models
1
NPN
PNP
Models with bank function
Models with RS-232C and
RS-422 interfaces
F10-C25
8 (one model per bank)
NPN
F10-C30
PNP
F10-C35
NPN
F10-C50
PNP
F10-C55
Cables
Type
Model
RS-232C (cable length: 2 m)
F10-VR2
RS-422 (cable length: 2 m)
F10-VR4
8
Model
F10-C20
F10
F10
Specifications
Ratings/Characteristics
Heads
Optical and Lighting System Specifications
Specifications
Item
F10-S30R
Setting distance
F10-S15R
F10-S05R
100±10 mm
50±5 mm
33±3 mm
Sensing area
25 mm ´ 20 mm
12 mm ´ 10 mm
4.5 mm ´ 3.5 mm
Guide light projection size
A: 25 mm
B: 20 mm
C: 8 mm
D: 6 mm
E: 20 mm
A: 12 mm
B: 10 mm
C: 4 mm
D: 3 mm
E: 10 mm
A: 4.5 mm
B: 3.5 mm
C: 1.5 mm
D: 1.0 mm
E: 3.5 mm
(typ.)
(typ.)
(typ.)
Built-in lens
Focus: f9.8 (fixed)
Diaphragm: F2.8 (fixed)
Focus: f14.8 (fixed)
Diaphragm: F3.5 (fixed)
Object lighting method
Pulse lighting (pulse width is synchronized with electronic shutter in operation)
Object light source
(emission wavelength)
8 red LEDs (680 nm)
8 green LEDs (540 nm)
Main object color
combination
Black and white, green and
white, blue and white, and red
and black
Black and white, red and white, green and white, blue and white,
green and black, and blue and black
Guide light projection source
(emission wavelength)
1 green LED (540 nm)
1 blue LED (470 nm)
Guide light projection method
Pulse lighting
Camera Image Performance Specifications
Specifications
Item
F10-S30R
F10-S15R
F10-S05R
Camera image element
1/5-inch CCD
Shutter function
Electronic shutter at a speed range between 1/34722 s and 1/2894 s (automatically set during
teaching)
General Specifications
Item
Specification
Ambient temperature
Operating:
Storage:
0°C to 40°C (with no icing or condensation)
--25°C to 60°C (with no icing or condensation)
Ambient humidity
Operating:
Storage:
35% to 85% (with no condensation)
35% to 85% (with no condensation)
Operating environment
With no corrosive gas
Input power supply
16.2 to 19.8 VDC (provided from amplifier)
Current consumption
150 mA max.
Insulation resistance
20 MW min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Degree of protection
IEC 60529 IP64
Vibration resistance
(when using mounting bracket)
10 to 150 Hz, half-amplitude of 0.75 mm max. or 100 m/s2 max. for 32 min each in X, Y, and Z
directions
Shock resistance
(when using mounting bracket)
Peak acceleration: 300 m/s2 3 times each in X, Y, and Z directions
Connection
Prewired (standard cable length: 2 m)
Casing material
Case:
Front cover:
Weight (when packed)
Approx. 400 g (Unit: approx. 300 g (including cable))
Accessories provided
Mounting bracket, 8 x M4 mounting screws, instruction manual
Aluminum die cast
Acrylic resin
9
F10
F10
Amplifiers
Performance Specifications
Specification
Item
Model
F10-C20/C30/C50
F10-C25/C35/C55
Output type
NPN
PNP
Measurement item
Pattern measurement/plain measurement
Number of models
C20/C25: 1 model, C30/C35/C50/C55: 1 model per bank
Bank selection
C20/C25: None, C30/C35/C50/C55: 8 banks
Automatic teaching
function
Yes
Model size
Normal or wide mode (selectable)
Measurement processing
time
3.6 ms in normal mode and 10.8 ms in wide mode (continuous operation)
Output signal (2 points)
Control output and enable output: NPN open
collector with load voltage of 30 V max., load
current of 50 mA max. and residual voltage of 1.2
V max.
Output selection
Matching output: ON when image matches the registered model.
Control output and enable output: PNP open
collector with load voltage of 30 V max., load
current of 50 mA max. and residual voltage of 2.0
V max.
Not matching output: ON when image does not match the registered model.
Input signal
C20/C25 (4 points)
C30/C35/C50/C55
(7 points)
External trigger input (with minimum pulse width of
1 ms), continuous measurement input, moving
object teaching input, or stationary object teaching
input
External trigger input (with minimum pulse width of
1 ms), continuous measurement input, moving
object teaching input, or stationary object teaching
input
Input is ON:
Input is ON:
Short-circuited to 0 V with
short-circuit current of 1 mA max. or
1.5 V max.
Input is OFF: Open or input voltage of 5 V min.
(Max. input voltage: +26.4 VDC)
Short-circuited to Vcc or 9 V min.
(Max. input voltage: +26.4 VDC)
Input is OFF: Open or input voltage of 5 V max.
Head interface (1 channel)
Available Head:
Indicators
Result indicator:
Level indicators:
Threshold indicators:
Status indicators:
F10-S30R, F10-S15R, or F10-S05R
Operation interface
Teach/display button (TEACH/DISPLAY), UP/DOWN selection buttons, mode selector
(TEACH/MON/RUN), 5 DIP switch pins: Automatic teaching (OFF/ON), model size (NORMAL/WIDE),
OFF-delay timer (OFF/ON), matching/not matching (output ON for matching object/non-matching object),
and external input (C50/C55 only) (LINE: To use the input line for external inputs in RUN mode;
RS-232C/422: To use serial communications for external inputs in RUN mode)
1 orange LED
8 green LEDs
7 red LEDs
3 on the C20/C25, or 7 on the C30/C35/C50/C55
General Specifications
Specification
Item
Ambient temperature
Operating:
Storage:
0°C to 50°C (with no icing or condensation)
--25°C to 65°C (with no icing or condensation)
Ambient humidity
Operating:
Storage:
35% to 85% (with no condensation)
35% to 85% (with no condensation)
Operating environment
With no corrosive gas
Input power supply
21.6 to 26.4 VDC (with ripple)
Current consumption
300 mA max.
Insulation resistance
20 MW min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Degree of protection
IEC 60529 IP40
Vibration resistance
10 Hz to 150 Hz, half-amplitude of 0.75 mm max. or 100 m/s2 max. for 32 min each in X, Y, and Z
directions
Shock resistance
Peak acceleration: 300 m/s2 3 times each in X, Y, and Z directions
Connection
Prewired (standard cable length: 2 m)
Casing material
ABS
Weight (when packed)
Approx. 300 g (Unit: approx. 200 g (including cable))
Accessories provided
Instruction manual
10
F10
F10
Engineering Data
Data Characteristics
F10-S30R
Shift angle
Rotation
·
The Head is inclined 15° to the sensing
object.
Area Position Characteristics
(in Y Direction)
Area Position Characteristics
(in X Direction)
Level indicator
Level indicator
The following data is obtained on the basis
of sample sensing objects, each of which is
as large as this size (A). (Typical example)
Angle of rotation
Level indicator
Shift angle
Rotation Characteristics
·
In X direction (mm)
In Y direction (mm)
Distance Characteristics
Shift Angle Characteristics
(in X Direction)
Shift Angle Characteristics
(in Y Direction)
Level indicator
Level indicator
(W.D. 100 mm)
Level indicator
(W.D. 100 mm)
W. D. (mm)
(W.D. 100 mm)
Shift angle in Y direction (°)
Shift angle in X direction (°)
(W.D. 100 mm)
(W.D. 100 mm)
F10-S15R
Shift angle
Rotation
Shift angle
·
The following data is obtained on the basis
of sample sensing objects, each of which is
as large as this size (A). (Typical example)
·
The Head is inclined 15° to the sensing
object.
Area Position Characteristics
(in Y Direction)
Level indicator
Level indicator
Level indicator
Area Position Characteristics
(in X Direction)
Rotation Characteristics
Angle of rotation
Shift Angle Characteristics
(in X Direction)
(W.D. 50 mm)
Shift Angle Characteristics
(in Y Direction)
Level indicator
Level indicator
W. D. (mm)
In Y direction (mm)
(W.D. 50 mm)
Level indicator
Distance Characteristics
In X direction (mm)
(W.D. 50 mm)
Shift angle in X direction (°)
(W.D. 50 mm)
Shift angle in Y direction (°)
(W.D. 50 mm)
11
F10
F10
F10-S05R available soon
12
F10
F10
Nomenclature
Heads
F10-S30R
Teaching area
Guide light (green)
F10-S30R with 2-m standard cable
Object lighting (red)
100±10 mm
Sensing side
Sensing area (field of vision)
F10-S15R
Teaching area
Guide light (blue)
Object lighting (green)
50±5 mm
F10-S15R with 2-m standard cable
Sensing area (field of vision)
Sensing side
F10-S05R
Teaching area
Guide light (blue)
Object lighting (green)
33±3 mm
F10-S05R with 2-m standard cable
Sensing area (field of vision)
Sensing side
13
F10
F10
Amplifiers
F10-C20/C25
F10-C30/C35/C50/C55
(1) Level
indicators
(3) Threshold
indicators
(5) Teach/
display
button
(2) Result
indicator
(1) Level
indicators
(2) Result
indicator
(4) Status
indicators
(3) Threshold
indicators
(4) Status indicator/bank
number
display
(6) UP/DOWN
selection
buttons
(7) Mode
selector
(8) Measurement
item selection
switch
(TEACH/
MON/RUN)
(5) Teach/
display
button
F10-C20/C25
PATT (Pattern measurement): Degree of conformity with model
PLN (Plain measurement)
DEV: Deviation level
AVE: Average density
F10-C30/C35/C50/C55
p:
Pattern measurement:
d:
Plain measurement:
a:
Plain measurement:
(7) Mode
selector
(8) Measurement
item/bank number selection
switch
(TEACH/
MON/RUN)
Not available
with
F10-C30/C35.
(9) DIP switch
(9) DIP switch
(1) Displays measurement values (degree of conformity with the
registered model).
(2) ON: Lit
OFF: Not lit
(3) Displays the threshold.
(4) Displays type of value displayed on the level indicator.
(6) UP/DOWN
selection
buttons
(8) S Changing Measurement Items
PATT
Automatically switches
PATTSPLN
PATT/BANK between pattern measurement and plain
measurement depending on the taught model.
Executes pattern
PATT
PATT/BANK measurement only.
PATTSPLN
S Bank Selection Mode
(F10-C30/C35/C50/C55)
PATT/BANK Enters the mode for
selecting and setting
the bank in TEACH
Mode.
PATTSPLN
Degree of conformity model
Deviation level
Difference from average density
Also displays bank number for F10-C30/C35/C50/C55
(5) Starts teaching.
Switches display item.
(6) Changes the threshold value.
Changes measurement item selection level for plain measurement.
Changes bank number for F10-C30/C35/C50/C55.
(7) TEACH: Teaching Mode
MON: Monitor Mode
RUN:
Run Mode
Pattern Measurement
Measures the degree with which the pattern and the
detected image match to differentiate OK and NG images.
Registered pattern
Sensing object
Plain Measurement
Determines the deviation level and average density to
differentiate OK and NG images.
Plain
Color
Stain
Pattern
Teaching status
(plain)
14
OK
NG
NG
NG
F10
F10
(9) DIP Switch
All the DIP switch pins are set to OFF at the factory.
=
Automatic Teaching
A.T. ON: Teaching area automatically selected
A.T. OFF: Teaching area fixed
A.T. ON
Automatically selects the pattern most
suitable for the model. The part within the
detection range where the deviation level
between the background and the target is
taken as the most suitable pattern for the
model.
Most
suitable
Too pale
Slightly
pale
Registers the pattern with the
greatest deviation level with the
background.
*If the pattern is at the very edge of, or
slightly outside, the detection range, it
may not be correctly taught. Make sure
the pattern is as close as possible to the
center of the detection range.
A.T. OFF
Registers only the pattern within the
teaching area as the model.
Model Size
Registers the pattern within the
frame as the model.
Normal Mode
Teaching area:
Divides the
pattern into
three, and registers it as
three models.
Wide Mode
WD: Wide mode
NM: Normal mode
Model 1
Model 2
Detection Range:
Teaching Area:
Shows the range of Registers this range Model 1
the detection area. as the model.
detection
range
OFF Delay Timer
Model 3
Model 2
detection
range
Model 3
detection
range
Use wide mode if the pattern in one direction is comparatively long, e.g., a production date.
The measuring time for wide mode, however, takes three times longer than Normal Mode, as
the pattern is processed as three models instead of one.
TMR: Delays the output operation when the control output goes from ON to OFF (Default value is
40 ms. Refer to the Operation Manual for the Unit for changing procedure).
No Marking: Timer OFF.
Matching/Not Matching
Output ON when object does not match registered model.
Output ON when object matches registered model.
External Input (F10-C50/C55 only)
LINE: Executes external input in RUN mode via input line.
RS-232C/422: Executes external input in RUN mode via serial communications.
15
F10
F10
Installation
Mounting Angle
·
·
Incline the Head by 15° and mount the Head so that no regular reflection light affects the Sensor.
Use the provided Mounting Bracket to mount the Head.
Simulation
Sensor direction
F10-S30R
F10-S15R
F10-S05R
F10-S30R: 100±10 mm
F10-S15R: 50±5 mm
F10-S05R: 33±3 mm
15° 15°
15°
Production
line direction
Line direction
Note:
Position the sensor perpendicular to the direction of motion of the target object.
Connection with Peripherals (F10-C50/C55 Only)
You can input the measurement trigger and output the measurement results via an RS-232C port. You can also back up the settings in an IBM
PC/AT or compatible. Refer to the Operation Manual for the Unit for details on communications commands.
1:1 Connection
System configuration
Use F10 products for items marked with an asterisk.
*F10-VR2
RS-232C Cable
F10-C50/C55
16
IBM PC/AT or
compatible
F10
F10
Multidrop Connections
A maximum of 31 F10-C50/C55 Sensors can communicate with an IBM PC/AT or compatible by connecting though RS-232C/422 converters.
Recommended Link Adapters (manufactured by OMRON)
Link Adapter:
B500-AL004
Branching Link Adapter: B500-AL001
Note: When using a B500-AL004 Branching Link Adapter, be sure to enable terminating resistance and include a terminating resistance in
the last link adapter according to the following:
Between RDA(--) and RDB(+): 220 W (1/2 W min.)
Between SDA(--) and SDB(+): 220 W (1/2 W min.)
System configuration
Use F10 products for items marked with an asterisk.
IBM PC/AT or
compatible
Link Adapter
Branching Link Adapter
Branching Link Adapter
*F10-VR4
RS-422 Cable
F10-C50/C55
Signal
*F10-VR4
RS-422 Cable
F10-C50/C55
*F10-VR4
RS-422 Cable
F10-C50/C55
F10-VR4
RS-422 Cable: D-sub 9-pin connector (2 m)
F10-VR2
RS-232C Cable: D-sub 9-pin connector (2 m)
Pin No.
Branching Link Adapter
Name
Pin No.
Signal
Name
2
SD (TXD)
Send data
1
RDB (+)
Receive data (+)
3
RD (RXD)
Receive data
3
SG (GND)
Signal ground
5
SG (GND)
Signal ground
5
SDB (+)
Send data (+)
6
RDA (--)
Receive data (--)
9
SDA (--)
Send data (--)
Note:
1. Signal and name are in reference to the F10.
2. Secure the connector with, for example, binding tape.
17
F10
F10
Operation
I/O Circuit Diagram
F10-C20 NPN Models
F10-C25 PNP Models
There are gray, green, and red input lines, but they are not used with
this model. Take steps to ensure that these lines will not be short-circuited with other lines.
There are gray, green, and red input lines, but they are not used with
this model. Take steps to ensure that these lines will not be short-circuited with other lines.
Level indicators
(8-level
green
LEDs)
Result
indicator
(1-level
orange
LED)
Amplifier main
circuit
Status
indicators
(3-level
green
LEDs)
Threshold
indicators
(7-level red
LEDs)
Brown (Vcc)
Brown (Vcc)
Level indicators
(8-level
green
LEDs)
Load
Black
Load
Orange
Yellow
Purple
21.6 to 26.4 VDC
Pink
Blue
(GND)
FG (see note)
Brown (Vcc)
Load
Black
Black
ENAB
Load
Orange
Load
Blue
(GND)
Shield
FG (see note)
Brown (Vcc)
Level indicators
(8-level
green
LEDs)
Load
Orange
Yellow
Purple
Yellow
Purple
Pink
Result indicator
(1-level
orange
LED)
Pink
White
CONT
Gray
BANK1
Green
BANK2
Red
BANK3
Blue
(GND)
FG (see note)
White
Gray
Amplifier main
circuit
21.6 to 26.4 VDC
Threshold indicators
(7-level
red
LEDs)
Green
21.6 to 26.4 VDC
Red
Status
indicators
(3-level
green
LEDs)
Bank
No. indicators
(7-level
red
LEDs)
Black
Orange
Blue
(GND)
ENAB
Load
Load
Shield
FG (see note)
For normal operation, ground or connect the shielded cable to 0 V. The shield is not connected to the interior or casing.
Signal
Function
OUTPUT
Control output
ENAB
Enabled output
S_TEACH
Stationary object teaching input
M_TEACH
Moving object teaching input
TRIG
Measurement trigger input
CONT
Continuous measurement input
BANK1
Bank switching input
(F10-C30/C35/C50/C55)
BANK2
BANK3
18
21.6 to 26.4 VDC
F10-C35/C55 PNP Models
I/O Signals
·
White
Status
indicators
(3-level
green
LEDs)
Threshold
indicators
(7-level red
LEDs)
White
Shield
Note:
Pink
Amplifier main
circuit
F10-C30/C50 NPN Models
Status
indicators
(3-level
green
LEDs)
Bank
No. indicaThresh- tors
old indi- (7-levcators el red
(7-level LEDs)
red
LEDs)
Purple
Result indicator
(1-level
orange
LED)
Shield
Level indicators
(8-level
green
LEDs)
Result indicator
(1-level
orange
LED)
Amplifier main
circuit
Yellow
All input signals are enabled in RUN mode only.
Switching Banks (F10-C30/C35/C50/C55)
You can switch banks by connecting BANK1 to BANK3 as shown
below.
Bank No.
BANK1
BANK2
BANK3
Bank 0
OFF
OFF
OFF
Bank 1
ON
OFF
OFF
Bank 2
OFF
ON
OFF
Bank 3
ON
ON
OFF
Bank 4
OFF
OFF
ON
Bank 5
ON
OFF
ON
Bank 6
OFF
ON
ON
Bank 7
ON
ON
ON
F10
F10
Setting Procedure
1. Pattern Registration (TEACH Mode)
Use the following procedure to register measurement criteria.
(1) Set the mode selector to TEACH.
(2) Make the automatic teaching and model size settings on the DIP switch.
If using an F10-C30/C35/C50/C55, go to step (3) to set the bank number. If using an F10-C20/C25, go to step (5).
(3) Set the measurement item/bank number selection switch to PATT/BANK. Bank No. 0 will be displayed.
POINT
Banks
Each F10-C30/C35/C50/C55 Sensor
has eight banks for storing data, and a
different threshold value can be stored in
each of the eight banks. Use this function to take measurements under various conditions. You can switch operation
simply by switching banks.
(4) Press the UP/DOWN select buttons to set the bank number.
(5) Use the measurement item (bank number) selection switch to set the measurement method.
(6) Press the teach/display button after locating the sensing object in the sensing area.
Measurement Items: PATT/BANK
Checking the degree of
suitability of the model
Optimum
for a
model
Not fit for
a model
8
7
6
5
4
3
2
1
Teaching successful
Press the
teach/display
button.
Locate the sensing object in the
sensing area so that the degree
of suitability for a model will be
indicated.
8
7
6
5
4
3
2
1
Teaching unsuccessful
Buzzer
sounds
The level indicators are all
lit for 0.5 s and the buzzer
sounds twice.
8
7
6
5
4
3
2
1
Buzzer
sounds
The threshold indicators all flash
while the buzzer sounds four times.
The deviation level is insufficient.
Change the location of the Sensor
and try again.
19
F10
F10
Measurement Item: PATT/PLN
Whether measurement is patterned or plain is determined automatically by comparing the deviation level with the background within the
detection range. When teaching is finished, all the level indicators will light for 0.5 s, and the buzzer will sound twice.
Pattern Measurement
Plain Measurement
The deviation level will become high if the sensing object has a pattern. If the deviation level is higher than the set level of measurement
item selection, pattern measurement will be performed.
The deviation level will be set to low if the sensing object has no
pattern. If the set level of measurement item selection is higher than
the deviation level, plain measurement will be performed.
High
High
8
8
7
7
A
6
6
Automatic
selection
5
Deviation
4
Deviation
2
2
1
Sensing area
Low
Measurement item
selection level
The portion with the highest deviation is
registered as a model.
4
3
3
Sensing area
5
Approx. 3.0 mm
(F10-S30R)
Approx. 1.5 mm
(F10-S15R)
Approx. 0.8 mm
(F10-S05R)
1
Low
Measurement item
selection level
The deviation and average density in the area enclosed by dotted
lines are registered. The dotted lines are not projected.
Plain measurement will be performed if the pattern is close to the edge of
the sensing area.
Teaching is performed in the area enclosed
by dotted lines inside the sensing area. The
pattern close to the edge of the sensing area
is not registered as a model because such a
pattern may not be always located in the
sensing area and accurate measurement
cannot be performed. In this example, the
deviation level in the area enclosed by the
dotted lines is small. Therefore, plain measurement will be performed.
POINT
The set level of measurement item selection is increased
or decreased by pressing the SELECT buttons. Adjust the
level according to the background and deviation. The level
is factory-set between 2 and 3.
If the object has some light-color lines or light-color patterns, pattern measurement may be performed. In this
case, by increasing the set level of measurement item
selection, plain measurement will be performed.
Note:
Teaching Area
The deviation and average density in the teaching area are registered in the above example. In other words, the sensing area is
restricted so that the pattern close to the edge will not influence
the results of object discrimination.
Do not turn OFF the Sensor before the Sensor is set to MONITOR mode, otherwise the teaching data will be lost.
2. Threshold Adjustment/Sample Test (MONITOR Mode)
The Sensor operates in MONITOR mode for threshold level adjustments and desktop sample tests for object discrimination with no signal
output. No external output operation signal or external input signal is accepted in MONITOR mode.
(1) Set the mode selector to MON.
Measurement continues as long as the selector is set to MON.
Pattern Measurement
On the basis of the registered model, the level indicator indicates the degree of conformity of the sensing object.
·
·
Status indicators, F10-C20/C25
Pattern
measurement
DEV
PLN
Degree of
conformance
with model
Status indicator, F10-C30/C35/C50/C55
Press the Switch
Display Item button
Bank No.
(Returns to bank number display no operation is performed for 5
seconds.)
AVE
Pattern
measurement
Closer to model
in appearance
Not close to model
in appearance
The closer to the model in appearance,
the higher the level.
20
If no sensing object is within the sensing
area or if the sensing object is greatly different from the model, the level will be lower.
F10
F10
Plain Measurement
Press the teach/display button to change the display (DEV-AVE).
·
Status indicators (F10-C20/C25)
PATT
DEV lit
Deviation level
Plain measurement
Deviation
level is
small
Difference from average
density during teaching
·
Status indicator (F10-C30/C35/C50/C55)
Plain measurement
Deviation
level is
Increases the smaller
great
the deviation level.
DEV (deviation level)
Returns to bank number
display if no operation is
performed for 5 seconds.
Press the teach/
display button
Bank No.
Displays the
mode indicating
the current level.
Returns to bank number
display if no operation is
performed for 5 seconds.
Difference from
registered pattern
is small
Press the
Display
Button
AVE lit
Average density
Plain measurement
Difference from
registered pattern
is great
AVE (difference from taught
average density)
Increases the smaller the
deviation level compared
with the taught average
density.
(2) Press the UP/DOWN selection buttons to adjust the threshold.
Adjust the threshold to the most suitable level by monitoring the level indicator.
Altered threshold values will not be saved unless the mode selector is changed once to either RUN or TEACH.
Pattern Measurement
In wide mode, the pattern with the lowest degree of conformance among the three models is selected.
Plain Measurement
Set the threshold values for both DEV (deviation level) and AVE (average density). If either is lower than the threshold value, the discrimination result will be set to OFF.
Closer to model
in appearance
Threshold value
Threshold value
Not closer to model
in appearance
Turns ON if the measurement value
is higher than the threshold.
The result indicator and output
signal are ON. (See note.)
Note:
Turns OFF if the measurement
value is lower than the threshold.
The result indicator and output
signal are OFF. (See note.)
Use the DIP switch to turn ON and OFF the output signal. Refer to Nomenclature for details.
21
F10
F10
3. Performing Measurement in Response to External Input Signals (RUN Mode)
(1) Set the mode selector to RUN.
When the switch is set to RUN mode, measurements are made in response to external input signals.
Relationship between the F10 I/O terminal operations and ON/OFF indications in the timing charts are as shown in the following table.
Indication in timing charts
Signal
Note:
NPN (F10-C20/C30/C50)
PNP (F10-C25/C35/C55)
Input
TRIG (pink)
CONT (white)
S_TEACH (yellow)
M_TEACH (purple)
BANK1 (gray) (see note)
BANK2 (green) (see note)
BANK3 (red) (see note)
ON
GND
Vcc
OFF
OPEN
OPEN
Output
OUTPUT (black)
ENAB (orange)
ON
GND
Vcc
OFF
Vcc
GND
F10-C20/C25 do not have banks 1 to 3.
CONT Mode
In CONT mode, the Sensor is in sensing operation repeatedly while
the CONT signal is ON. The measurement result is renewed once
per measurement cycle, and output.
Measurement cycle: Tout
Normal mode: 3.6 ms
Wide mode: 10.8 ms
Plain measurement: 7.2 ms
TRIG Mode
The Sensor in TRIG mode is used for object measurement only
once in synchronization with the rising edge of the TRIG signal and
the result is output.
TRIG
Normal mode
OUTPUT
3.6 ms max.
ENAB
Wide mode (plain measurement)
POINT
Turning the Guide Light ON and OFF:
In RUN mode, even when synchronous measurement
is not being executed, the guide light will normally be
ON. It is possible to turn the guide light OFF (and ON
again) by pressing the UP selection button as required.
While the guide light is being turned ON or OFF, the
ENAB signal is turned OFF, and no external inputs can
be received.
The OUTPUT signal is turned OFF when the UP selection button is pressed.
Press and hold
down the UP
selection button.
OUTPUT
3.6 ms max.
OUTPUT
ENAB
Minimum ON width for the trigger signal is 1 ms.
ENAB
The OUTPUT signal is stored until the measurement results are refreshed.
Measurement cycle: Tout
ENAB signal:
Guide light
OFF width is 10 ms in normal mode.
Turns ON when the OUTPUT signal is refreshed.
22
0.7 s max.
ON: Lit
OFF: Unlit
Normal mode: 7.2 ms max.
Wide mode: 14.4 ms max.
Plain measurement: 10.8 ms max.
F10
F10
External Teaching in RUN Mode
In RUN mode, a model can be registered by external signal input using either of the following methods.
Note:
The data of the model is stored in the EEPROM when the teaching process of the Sensor completes. Therefore, do not turn OFF the
Sensor during the teaching process.
If the Sensor is turned OFF, an EEPROM data error will result when the Sensor is turned ON again. In this case, perform proper
teaching and threshold level adjustments again.
Stationary Object Teaching (S_TEACH)
Stationary object teaching is performed with the TRIG signal input or CONT signal input after external S_TEACH signal input.
Therefore, do not move the object until teaching is completed.
(1) Provide S_TEACH signal input.
(1)
S_TEACH
(2) Check that the ENAB signal is OFF.
(4)
(3) Check that the stationary object is in the teaching area (or in
the sensing area if A.TEACH is set to ON).
(4) Provide external CONT or TRIG signal input.
(2)
(5) After teaching is completed, the ENAB signal will turn ON. At
Teaching in process
that time, check the status of the OUTPUT signal.
(6) The OUTPUT signal will be ON if teaching is successfully
completed.
(7) The OUTPUT signal will be OFF if teaching is unsuccessful.
(8) Turn the S_TEACH signal OFF to complete the teaching process. If teaching has been unsuccessful, the Sensor will remain in the previous status. Therefore, perform teaching
again.
(8)
(5)
(6)
(7)
Moving Object Teaching (M_TEACH)
Moving object teaching is performed by using more than one object. Perform this teaching if the sensing objects cannot be stopped. After
M_TEACH signal input, this teaching requires six processes in synchronization with external trigger input. The Sensor will not be in detection
operation during the teaching process. External trigger input will be ignored after it is turned ON six times.
50 ms min.
(1) Provide external M_TEACH signal input.
(2) Check that the ENAB signal is OFF.
(8)
(1)
M_TEACH
(3) Provide TRIG signal input in synchronization with the mea(4)
surement timing of the sensing objects used for teaching.
(3)
(4) Repeat step 3 six times.
(5) After teaching is completed, the ENAB signal will turn ON. At
(5)
(2)
that time, check the status of the OUTPUT signal.
Teaching in process
(6) The OUTPUT signal will be ON if teaching is successfully
(6)
completed.
(7)
(7) The OUTPUT signal will be OFF if teaching is unsuccessful.
(8) Turn the M_TEACH signal OFF to complete the teaching process. If the teaching has been unsuccessful, the Sensor will
remain in the previous status. Therefore, perform teaching
again. The teaching operation will be disabled if the
M_TEACH signal is turned OFF during the teaching process.
Enable Output
Enable output turns ON when the Sensor is ready to be in sensing operation. Therefore, enable output will turn OFF if the mode selector is set
to TEACH or MON.
Enable output is OFF in the following cases in RUN mode.
1.
2.
3.
4.
5.
6.
The Sensor is in teaching process with external teaching input.
The Sensor is in sensing operation with TRIG signal input.
No teaching data has been registered.
The hardware fails.
The bank is being switched.
The guide light is being turned ON or OFF.
RS-232C/422 Command Inputs (F10-C50/C55 Only)
Communications with external devices, such as an IBM PC/AT or compatible, is possible via the RS-232/422 port. Refer to the Operation
Manual for the unit for details on the communications commands.
23
F10
F10
Troubleshooting
Problem
Head disconnection error
8
Buzzer
sounds
The Head is not connected properly and no
image signal is obtainable.
7
6
5
4
3
2
1
Hardware error
2
1
If the same error occurs again, the
Head may be broken. Consult your
OMRON representative.
Consult your OMRON representative.
Head data read error
1.The EEPROM data of the Head is not
readable.
7
6
5
4
3
Note:
This LED of the threshold
indicators flashes and the
buzzer sounds.
8
Buzzer
sounds
Connect the Head and turn the Sensor
OFF and ON.
A hardware failure, such as CPU runaway,
has resulted.
7
6
5
4
3
Remedy
This LED of the threshold
indicators flashes and the
buzzer sounds.
8
Buzzer
sounds
Probable cause
This LED of the threshold
indicators flashes and the
buzzer sounds.
2.The data is illegal.
2
1
Buzzer
sounds
8
Amplifier data read error
Turn the Sensor OFF and ON.
7
6
1.The EEPROM data of the Amplifier is not
readable.
Note:
2.The data is illegal.
Note:
5
4
3
This LED of the threshold
indicators flashes and the
buzzer sounds.
2
1
Amplifier data write error
8
Buzzer
sounds
7
6
5
4
3
All internal data of the Amplifier may
be cleared.
If the same error occurs again after
turning the Sensor OFF and ON,
consult your OMRON representative.
This LED of the threshold
indicators flashes and the
buzzer sounds.
1.No EEPROM data is written to the
Amplifier.
2.The data is illegal.
2
1
Head type error
8
Buzzer
sounds
7
6
5
4
3
This LED of the threshold
indicators flashes and the
buzzer sounds.
An F10-S30/S15 is connected to the head.
Connect an F10-S30R/S15R/S05R to the
head.
2
1
Buzzer
sounds
8
Teaching data setting error
7
6
The Sensor was set to MONITOR or RUN
mode before teaching completed.
5
4
3
2
1
24
All the LEDs of the
threshold indicators flash
and the buzzer sounds
three times.
Perform the teaching of the Sensor in
TEACH mode.
Refer to 1. Pattern Registration
(TEACH Mode) on page 19.
F10
F10
Problem
Probable cause
8
Buzzer
sounds
7
6
5
4
3
2
1
Remedy
Serial buffer overflow error
Send buffer overflow
Either the send buffer or receive buffer has
become full during communications.
Change the communications settings.
Wait for a response from the F10, then
send the command.
This LED of the threshold
indicators flashes and the
buzzer sounds three
times.
Control output (OUTPUT) and enable
output are OFF, and will not turn ON.
Receive buffer overflow
A current exceeding the rated value has
flowed to the output transistor and the
overcurrent protective circuit has been
triggered.
Reduce the current so that it will not
exceed the rated value.
Note: If the output does not turn ON even
after reducing the current below the rated
value, contact your OMRON
representative.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Amplifiers
F10-Cj
F10-C50/C55 only
5.7-dia. 11-core vinyl-insulated round cable, standard length: 2 m
(Conductor cross-section: 0.2 mm2, insulator diameter: f 1.0 mm).
Mounting Dimensions
2-M4
25
F10
F10
Heads
F10-SjR
The Mounting Bracket can be attached
to this side as well.
Ferrite core
(75)
14.7-dia. connector
(125)
5.8-dia. Vinyl-insulated round cable,
standard length: 2 m
Mounting hole
(16.5)
Mounting hole
(22)
(52)
2-M4 pan-head screw
(16.7)
Mounting Dimensions
Two, M4
37±0.2
Mounting Bracket
Protruding part
R1 max.
26
F10
F10
Precautions
Setup
General Precautions
The F10-Cj Amplifier radiates heat. If more than one Unit is
installed side-by-side, make sure that there is a minimum space of
5 mm between adjacent Units as shown below.
The user must operate the product according to the performance
specifications described in the brochure.
Before using the product under conditions which are not described
in the brochure or applying the product to nuclear control systems,
railroad systems, aviation systems, vehicles, combustion systems,
medical equipment, amusement machines, safety equipment, and
other systems, machines, and equipment that may have a serious
influence on lives and property if used improperly, consult your OMRON representative.
5 mm min.
Amplifiers
Do not disconnect or connect the Head while the Sensor is turned
ON.
The F10-S30R cannot detect red objects with white backgrounds.
Use the F10-S15R instead.
The F10-S15R cannot detect green objects with white backgrounds. Use the F10-S30R instead.
Make sure that the length of the cable of the Amplifier is no longer
than 20 m.
Make sure that the tightening torque of each screw on the Head and
Amplifier is no greater than 1.2 N S m.
The connector on the Amplifier and the metal screws on the bottom
of the Amplifier are connected internally to 0-V terminal of the Amplifier.
The operating ambient temperature range of the Amplifier is between 0°C and 50°C under the following conditions.
1. Provide enough ventilation to the Amplifier. If more than one
Unit is installed side-by-side, provide a ventilation fan for
efficient ventilation.
2. Do not install the Amplifier close to heat-radiating devices
such as heaters, transformers, and high-capacity resistors.
3. If power lines with high current for motors are wired close to
the Amplifier, make sure that the Amplifier operates normally
and take proper measures so that the power lines will not
have a bad influence on the operation of the Amplifier.
Others
Application Precautions
!
Caution
Do not make mistakes in wiring, such as mistakes in polarity.
Doing so may cause Sensor damage or malfunction.
Do not apply voltage exceeding the rated range. Doing so may
cause Sensor damage or malfunction.
Do not short-circuit the load. Doing so may cause Sensor damage or malfunction.
Organic solvents may damage the casing of the Amplifier,
which is made of ABS resin, and the transparent front panel of
the Head, which is made of acrylic resin. Do not use paint thinner or any other organic solvent to clean the product.
Be sure to set the locking mechanism on the cables and units
before use.
Do not use the Sensor in an environment where the degree of
protection is not satisfied.
Do not disassemble the Sensor. Doing so may cause malfunction or breakdown.
27
F10
F10
The product has been produced at OMRON Ayabe which obtained ISO9001-approval for its quality system
and ISO14001-approval for its environmental management system from international certification bodies.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Advanced Sensors Division
Sensing Devices and Components Division H.Q.
28th Fl., Crystal Tower Bldg.,
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan
Tel: (81)6-6949-6105/Fax: (81)6-6949-6149
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS, INC.
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
Authorized Distributor:
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)835-3011/Fax: (65)835-2711
OMRON (CHINA) CO. LTD.
21F, Beijing East Ocean Center
No. 24A Jian Guo Men Wai Da Jie
Chao Yang District, Beijing, 100022
China
Tel: (86)10-6515-5778/Fax: (86)10-6515-5810
28