Connector Terminal Box (Muting Terminals)
F39-TC5
CSM_F39-TC5_DS_E_4_1
Significantly reduces amount of wiring
between Safety Light Curtains and
Muting Sensors.
As of August 2008
• Provides IP67 protection against water and dust.
• Connection using connectors significantly reduces wiring work.
• The wiring status can be checked at a glance with the LED
indicators.
• The Support Software can be connected, enabling on-site
adjustment of a Light Curtain.
Be sure to read the “Safety Precautions” on page 7 and
the “Precautions for All Safety Sensors” .
Ordering Information
Connector Terminal Box
Classification
Applicable models
F3SJ-A@@@@P@@
F3SJ-B@@@@P@@
Specification
PNP
Muting Terminals
F3SJ-A@@@@N@@
F3SJ-B@@@@N@@
NPN
Type
Model with Muting Sensor Output Mode
Model
F39-TC5P01
Model with Override Mode
F39-TC5P02
Model with Muting Sensor Output Mode
F39-TC5N01
Model with Override Mode
F39-TC5N02
Optional Accessories (Sold separately)
Classification
Appearance
Model
Short-circuit Connector
F39-CN8
Waterproof Covers
XS2Z-22
Note: One short-circuit connector is included with the F39-T@01 for Muting Sensors.
Three waterproof covers are included with a Connector Terminal Box with Muting Sensor Output Mode (F39-TC5@01) and four waterproof
covers with a Connector Terminal Box with Override Mode (F39-TC5@02).
Order the above accessories only as spare parts.
Specifications (Refer to Instruction Sheet for details.)
Ratings
Rated voltage
24 VDC ±20% (at ambient temperature of 20°C)
Rated current
Power line: 2.4 A, Signal line: 0.3 A
Characteristics
Contact resistance
40 mΩ max. (connector section)
Insulation resistance
After applying 500 VDC for 60 s: 100 MΩ min.
Vibration resistance
Speed: 10 Hz to 500 Hz to 10 Hz in 20 minutes.
Simple vibration with full amplitude of 1.52 mm or 98 m/s2 (whichever has the smaller amplitude) for two
hours each in three directions X, Y, and Z (total of 6 hours).
Measured while connector is connected.
Shock resistance
490 m/s2 for 11 ms three times each along three axes, six directions X, Y, and Z (total of 18 times).
Measured while connector is connected. (MIL-STD-202F Test 213B, Condition A)
Ambient operating temperature
−25 to 70°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (with no icing or condensation)
Degree of protection
IP67
Accessories
Short-circuit connector (models with Muting Sensor outputs only), waterproof cover
1
F39-TC5
Connections
Internal Circuit Diagrams
PNP
Model with Muting Sensor Output Mode F39-TC5P01
CN3 (L)
F3SJ-A Emitter
CN4 (D)
F3SJ-A Receiver
CN2 (COMM)
Setting Console F39-MC21
or
PC Tool for F3SJ F39-GWUM
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4
Note: When a short-circuit connector is connected to
CN1, terminals 1 and 2, and terminals 3 and 4
will be short-circuited.
This connects the Muting Sensor input to
muting input 1 and muting input 2 of the F3SJ.
CN1
Muting Sensor output
1 2 3 4 5
(Brown) Power supply,
24 VDC
(Pink) Test input
(Purple) Reset input
(White) Safety output 2
(Black) Safety output 1
(Gray) Auxiliary output 1
(Red) External device monitoring input
(Blue) Power supply, 0 V
1 2 3 4
CN7 (MSA1) *
Muting Sensor A1
1 2 3 4
1 2 3 4
CN8 (MSB1) *
Muting Sensor B1
CN5 (MSA2) *
Muting Sensor A2
1 2 3 4
CN6 (MSB2) *
Muting Sensor B2
* Use the following connecting cable to connect the Muting Sensors:
M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output)
When using a Through-beam Photoelectric Sensor, use an XS2R-D426-@11-F Y-joint with Socket and Plug or similar product to connect the
transmitter and receiver.
Model with Override Mode F39-TC5P02
CN3 (L)
F3SJ-A Emitter
CN4 (D)
F3SJ-A Receiver
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
CN2 (COMM)
Setting Console F39-MC21
or
CN1
PC Tool for F3SJ F39-GWUM I/O auxiliary terminals
1 2 3 4
1 2 3 4 5
(Brown) Power supply,
24 VDC
(Pink) Test input
(Purple) Reset input
(White) Safety output 2
(Black) Safety output 1
(Gray) Auxiliary output 1
(Red) External device
monitoring input
(Blue) Power supply, 0 V
1 2 3 4
CN7 (MSA1) *
Muting Sensor A1
1 2 3 4
CN8 (MSB1) *
Muting Sensor B1
1 2 3 4
1 2 3 4
CN5 (MSA2) *
Muting Sensor A2
CN6 (MSB2) *
Muting Sensor B2
* Use the following connecting cable to connect the Muting Sensors:
M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output)
When using a Through-beam Photoelectric Sensor, use an XS2R-D426-@11-F Y-joint with Socket and Plug or similar product to connect the
transmitter and receiver.
2
F39-TC5
NPN
Model with Muting Sensor Output Mode F39-TC5N01
Note: When a short-circuit connector is connected to
CN1, terminals 1 and 2, and terminals 3 and 4
will be short-circuited.
This connects the Muting Sensor input to
muting input 1 and muting input 2 of the F3SJ.
CN3 (L)
F3SJ-A Emitter
CN4 (D)
F3SJ-A Receiver
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
CN2 (COMM)
Setting Console F39-MC21
or
CN1
PC Tool for F3SJ F39-GWUM Muting Sensor output
1 2 3 4
1 2 3 4 5
(Brown) Power supply,
24 VDC
(Pink) Test input
(Purple) Reset input
(White) Safety output 2
(Black) Safety output 1
(Gray) Auxiliary output 1
(Red) External device
monitoring input
(Blue) Power supply, 0 V
1 2 3 4
CN7 (MSA1) *
Muting Sensor A1
1 2 3 4
1 2 3 4
CN8 (MSB1) *
Muting Sensor B1
CN5 (MSA2) *
Muting Sensor A2
1 2 3 4
CN6 (MSB2) *
Muting Sensor B2
* Use the following connecting cable to connect the Muting Sensors:
M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output)
When using a Through-beam Photoelectric Sensor, use an XS2R-D426-@11-F Y-joint with Socket and Plug or similar product to connect the
transmitter and receiver.
Model with Override Mode F39-TC5N02
CN3 (L)
F3SJ-A Emitter
CN4 (D)
F3SJ-A Receiver
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
CN2 (COMM)
Setting Console F39-MC21
or
CN1
PC Tool for F3SJ F39-GWUM I/O auxiliary terminals
1 2 3 4
1 2 3 4 5
(Brown) Power supply,
24 VDC
(Pink) Test input
(Purple) Reset input
(White) Safety output 2
(Black) Safety output 1
(Gray) Auxiliary output 1
(Red) External device
monitoring input
(Blue) Power supply, 0 V
1 2 3 4
CN7 (MSA1) *
Muting Sensor A1
1 2 3 4
CN8 (MSB1) *
Muting Sensor B1
1 2 3 4
CN5 (MSA2) *
Muting Sensor A2
1 2 3 4
CN6 (MSB2) *
Muting Sensor B2
* Use the following connecting cable to connect the Muting Sensors:
M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output)
When using a Through-beam Photoelectric Sensor, use an XS2R-D426-@11-F Y-joint with Socket and Plug or similar product to connect the
transmitter and receiver.
3
F39-TC5
Wiring Diagrams
PNP
Model with Muting Sensor Output Mode F39-TC5P01
Note: The Key Cap for Muting
and the Muting Lamp can
be connected to either the
Emitter or the Receiver.
S1
0 V(Blue)
Safety output 1 (Black)
KM1
Safety output 2 (White)
Auxiliary output 1 (Gray)
External device monitoring input (Red)
F3SJ
Test input (Pink)
or
PC Tool
for F3SJ
F39-GWUM
Key Cap for Muting
F39-CN6 (orange)
S2 Reset input (Purple)
Muting Lamp
+24 V (Brown)
Setting Console
connector
F39-MC21
KM1
KM2
KM1 KM2
KM2
PC
Emitter
Receiver
+24 VDC
Muting Sensor (PNP)
0V
A2
A1
B1
CN8
CN7
M
OUT
IN
PLC
B2
CN6
CN5
CN4
CN3
CN2
CN1
Short-circuit connector
Model with Override Mode F39-TC5P02
Note: The Key Cap for Muting
and the Muting Lamp can
be connected to either the
Emitter or the Receiver.
Setting Console
F39-MC21
F3SJ
0 V (Blue)
Safety output 2 (White)
KM1
Safety output 1 (Black)
Auxiliary output 1 (Gray)
Reset input (Purple)
Key Cap for Muting
F39-CN6 (orange)
External device monitoring input (Red)
or
PC Tool for
F3SJ
F39-GWUM
Test input (Pink)
Muting Lamp
+24 V (Brown)
KM1
KM2
M
KM1 KM2
KM2
B1
CN8
CN7
B2
CN6
CN5
CN4
CN3
CN2
CN1
I/O Auxiliary Connector
Recommended:
XS2H-D521-@G0-A (5-pin, DC)
(1) +24 V
A1
S2 (2) Reset input
0V
A2
(4) Test input
+24 VDC
(3) 0 V
Receiver
Muting Sensor (PNP)
S1
Emitter
(5) Auxiliary output 1
PC
K3
4
F39-TC5
NPN
Model with Muting Sensor Output Mode F39-TC5N01
Note: The Key Cap for Muting
and the Muting Lamp can
be connected to either the
Emitter or the Receiver.
S1
0 V (Blue)
Safety output 2 (White)
KM1
Safety output 1 (Black)
Auxiliary output 1 (Gray)
External device monitoring input (Red)
F3SJ
Test input (Pink)
or
PC Tool for
F3SJ
F39-GWUM
Key Cap for Muting
F39-CN6 (orange)
S2 Reset input (Purple)
Muting Lamp
+24 V (Brown)
Setting Console
F39-MC21
KM1
KM2
KM1 KM2
KM2
M
PC
OUT
IN
PLC
Emitter
Receiver
+24 VDC
Muting Sensor (NPN)
0V
A2
A1
B1
CN8
CN7
B2
CN6
CN5
CN4
CN3
CN2
CN1
Short-circuit connector
Model with Override Mode F39-TC5N02
Note: The Key Cap for Muting
and the Muting Lamp
can be connected to
either the Emitter or the
Receiver.
Setting Console
F39-MC21
0 V (Blue)
Safety output 1 (Black)
Auxiliary output 1 (Gray)
KM1
Safety output 2 (White)
F3SJ
External device monitoring input (Red)
Key Cap for Muting
F39-CN6 (orange)
Reset input (Purple)
or
PC Tool for
F3SJ
F39-GWUM
Test input (Pink)
Muting Lamp
+24 V (Brown)
KM1
KM2
M
KM1 KM2
KM2
B1
CN8
CN7
B2
CN6
CN5
CN4
CN3
CN2
CN1
I/O Auxiliary Connector
Recommended:
XS2H-D521-@G0-A (5-pin, DC)
(3) 0 V
A1
S2 (2) Reset input
0V
A2
(4) Test input
+24 VDC
Muting Sensor (NPN)
S1
Receiver
(1) +24 V
Emitter
(5) Auxiliary output 1
PC
K3
5
F39-TC5
Dimensions
F39-TC5P01
F39-TC5P02
F39-TC5N01
F39-TC5N02
(Unit: mm)
14 dia.
Operation Indicator (green LED)
Power Indicator (green LED)
Three, 4.5-dia. holes
9 dia.
54
27
33
100
120
27
73
27
27
10
4.5
30.5
127
5000
6.5
21
• Case material: PBT
• Cable conductor cross-section: 0.34 mm2
Insulator diameter: 1.76 mm
F39-TC5P01
9
6
F39-TC5
Safety Precautions
!WARNING
The muting and override functions disable equipment safety
functions. Use separate procedures to ensure safety when the muting
and override functions are operating.
Position the Muting Sensors so that a distinction can be made
between the entry of an object or a human. If the muting function were
to operate when a human passed through, it may cause serious
injury.
Install a Muting Lamp where it can be seen from all work locations, so
that workers can check the status of the muting and override
functions.
Muting times must be precisely set according to the application by
qualified personnel who have received appropriate training. In
particular, if the muting time limit is to be set to infinity, the person who
makes the setting must bear responsibility.
Use two independent input devices for the muting inputs.
Install the F3SJ, Muting Sensors, or a protective wall so that workers
cannot enter hazardous areas while muting is in effect, and set muting
times.
Install override switches where they can be seen from the hazardous
area, and where they cannot be operated from within the hazardous
area. Before starting an override, check to make sure that nobody is
within the hazardous area.
Precautions for Safe Use
Installation Conditions
• Connector tightening torque: 0.39 to 0.49 N·m
• Panel mounting tightening torque: 0.6 to 0.8 N·m
(use metric 4 screws)
Handling
• Make sure that the power is turned OFF before connecting or
disconnecting the connector.
• Make sure that fasteners are tightened properly by hand.
(0.39 to 0.49 N·m)
The use of pliers may cause damage. If the screws are not
tightened properly, the degree of protection may not be obtained,
and the screws may come loose from vibration.
• If the cables are connected with the polarity reversed, the load will
not operate, or the operation indicator will not light.
• Make sure that signal lines are always connected through a load.
• Use Sensors that meet the specifications.
• Do not pull on the connectors and cables. Doing so may damage
the connector or break the cable.
• To avoid breaking the cable and damaging the connector, install
them in a location where there is no danger of stepping on them. If
you must install them in a location where they might be stepped on,
place a protective cover on them.
• When installing the product, do not bend the cable where it is
connected to the product.
• If you must bend the cable, make sure that the bend radius is
greater than 60 mm.
• If you are not going to install Sensors and switches, place
waterproof covers (XS2Z-22) on the connectors to protect the
contact surface.
Storage
Observe the following points when storing the product for an
extended period of time.
1. Make sure that the storage location is well protected against dust
and humidity.
2. Do not store the product close to areas where ammonia or
sulfurization gas is generated.
7
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
F39-GWUM F39-CN6