F3S-TGR-NMPR-20-05

F3S-TGR-NMPR-20-05

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON INDUSTRIAL AUTOMATION - F3S-TGR-NMPR-20-05 - Safety Interlock Switch, DPST-NC, Cable, 250 VAC,...

  • 数据手册
  • 价格&库存
F3S-TGR-NMPR-20-05 数据手册
Magnetic non-contact safety switches F3S-TGR-N@R Reed non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available. • Based on reed technology • Connect up to 6 switches in series • Operates with all Omron safety controllers • Operates behind stainless steel fittings • Non-contact – no abrasion – no particles • Compensation of mechanical tolerances • Suitable for high pressure cleaning, CIP/SIP processes due IP69K (pre-wired types) • Conforms to safety categories up PLe acc. EN ISO13849-1 Model Number Structure F3S-TGR-N@@R-@@-@@ 1 2 1. Type L: S: M: C: W: B: 3 4 Elongated Sensor Small Sensor Miniature Sensor Compact Sensor Wide Sensor Barell Sensor 2. Housing Material P: Plastic Housing M: Stainless Steel Housing H: Hygienic designed Stainless Steel Housing F: Special Food Type Stainless Steel Housing 4. Cable Length/connection 05: 5 m Cable 05-R*: 5 m Cable exit to the right 10: 10 m Cable 10-R*: 10 m Cable, exit to the right M1J8: M12 male connector, 8 pin, fitted with 250 mm cable M1J8-R*: M12 male connector, 8 pin, fitted with 250 mm cable exit to the right 08-L10**: M8 male connector, 4 pin 08-R10**: M8 male connector, 4 pin, exit to the right * only for F3S-TGR-NMPR and F3S-TGR-NMHR ** only for F3S-TGR-NMPR 3. Contact configuration 11*: 1 Normally Closed Contact (NC) + 1 Normally Open Contact (NO) 20*: 2 Normally Closed Contacts (NC) 21: 2 Normally Closed Contacts (NC) + 1 Normally Open Contact (NO) * only existing for some NMPR-types 1 F3S-TGR-N@R Ordering Information Polyester Housing Type Elongated Sensors Small Sensors Cable connection 5 m pre-wired 10 m pre-wired Compact Sensors Wide Sensors F3S-TGR-NLPR-21-M1J8 5 m pre-wired 10 m pre-wired F3S-TGR-NSPR-21-05 F3S-TGR-NSPR-21-10 5 m pre-wired 10 m pre-wired M12, 8 pin, fitted with 250 mm cable 5 m pre-wired, cable exit right 10 m pre-wired, cable exit right M12, 8 pin, fitted with 250 mm cable exit right M8, 4 pin, direct connector left side M8, 4 pin, direct connector right side M8, 4 pin, direct connector left side M8, 4 pin, direct connector right side 5 m pre-wired 2NC/1NO 2NC 1NC/1NO F3S-TGR-NSPR-21-M1J8 F3S-TGR-NMPR-21-05 F3S-TGR-NMPR-21-10 F3S-TGR-NMPR-21-M1J8 F3S-TGR-NMPR-21-05-R F3S-TGR-NMPR-21-10-R F3S-TGR-NMPR-21-M1J8-R F3S-TGR-NMPR-20-08-L10 F3S-TGR-NMPR-20-08-R10 F3S-TGR-NMPR-11-08-L10 F3S-TGR-NMPR-11-08-R10 F3S-TGR-NCPR-21-05 10 m pre-wired F3S-TGR-NCPR-21-10 5 m pre-wired F3S-TGR-NWPR-21-05 10 m pre-wired Barrel Sensors Order code F3S-TGR-NLPR-21-05 F3S-TGR-NLPR-21-10 M12, 8 pin, fitted with 250 mm cable M12, 8 pin, fitted with 250 mm cable Miniature Sensors Contact configuration 2NC/1NO F3S-TGR-NWPR-21-10 5 m pre-wired 10 m pre-wired F3S-TGR-NBPR-21-05 F3S-TGR-NBPR-21-10 M12, 8 pin, fitted with 250 mm cable F3S-TGR-NBPR-21-M1J8 Stainless steel housing Type Elongated Sensors Cable connection 5 m pre-wired 10 m pre-wired Contact configuration M12, 8 pin, fitted with 250 mm cable Small Sensors Barrel Sensors 2 5 m pre-wired 10 m pre-wired Order code F3S-TGR-NLMR-21-05 F3S-TGR-NLMR-21-10 F3S-TGR-NLMR-21-M1J8 2NC/1NO F3S-TGR-NSMR-21-05 F3S-TGR-NSMR-21-10 M12, 8 pin, fitted with 250 mm cable F3S-TGR-NSMR-21-M1J8 5 m pre-wired 10 m pre-wired F3S-TGR-NBMR-21-05 F3S-TGR-NBMR-21-10 M12, 8 pin, fitted with 250 mm cable F3S-TGR-NBMR-21-M1J8 F3S-TGR-N@R Hygienic and food types Type Small Sensors Small Sensors (Special food types) Cable connection 5 m pre-wired 10 m pre-wired Contact configuration M12, 8 pin, fitted with 250 mm cable F3S-TGR-NSHR-21-M1J8 5 m pre-wired 10 m pre-wired F3S-TGR-NSFR-21-05 F3S-TGR-NSFR-21-10 M12, 8 pin, fitted with 250 mm cable Miniature Sensors Order code F3S-TGR-NSHR-21-05 F3S-TGR-NSHR-21-10 2NC/1NO 5 m pre-wired 10 m pre-wired M12, 8 pin, fitted with 250 mm cable 5 m pre-wired, cable exit right 10 m pre-wired, cable exit right M12, 8 pin, fitted with 250 mm cable exit right F3S-TGR-NSFR-21-M1J8 F3S-TGR-NMHR-21-05 F3S-TGR-NMHR-21-10 F3S-TGR-NMHR-21-M1J8 F3S-TGR-NMHR-21-05-R F3S-TGR-NMHR-21-10-R F3S-TGR-NMHR-21-M1J8-R Accessories Cables 8-pin Cables 4-pin Actuators Mounting screws Spacer (8 mm, Set of 2pcs.)*1 *1 2m 5m 10 m 25 m 2m 5m 10 m 25 m for F3S-TGR-NLPR for F3S-TGR-NSPR for F3S-TGR-NMPR for F3S-TGR-NCPR for F3S-TGR-NWPR for F3S-TGR-NBPR for F3S-TGR-NLMR for F3S-TGR-NSMR for F3S-TGR-NBMR for F3S-TGR-NSHR for F3S-TGR-NSFR for F3S-TGR-NMHR Set of Torx safety screws (M4, 4 × 30 mm, 4 × 20 mm, 4 × 10 mm; incl. washers and Torx bit) for Elongated Sensors for Small Sensors for Miniature Sensors for Compact Sensors for Wide Sensors Order code Y92E-M12PURSH8S2M-L Y92E-M12PURSH8S5M-L Y92E-M12PURSH8S10M-L Y92E-M12PURSH8S25M-L XS3F-M8PVC4S2M-EU XS3F-M8PVC4S5M-EU XS3F-M8PVC4S10M-EU XS3F-M8PVC4S20M-EU F39-TGR-NLPR-A F39-TGR-NSPR-A F39-TGR-NMPR-A F39-TGR-NCPR-A F39-TGR-NWPR-A F39-TGR-NBPR-A F39-TGR-NLMR-A F39-TGR-NSMR-A F39-TGR-NBMR-A F39-TGR-NSHR-A F39-TGR-NSFR-A F39-TGR-NMHR-A F39-TGR-N-SCREWS F39-TGR-NLR-SPACER F39-TGR-NSR-SPACER F39-TGR-NMR-SPACER F39-TGR-NCR-SPACER F39-TGR-NWR-SPACER Spacers are needed to prefent influences if switch is mounted on ferromagnetic background (e. g. reduced switching distance, EMC influences) 3 F3S-TGR-N@R Control units Order code G9SE G9SE-201 G9SE-401 G9SE-221-T05 G9SE-221-T30 G9SA G9SA-301 G9SA-501 G9SA-321-T075 G9SA-321-T15 G9SA-321-T30 Safety relay units G9SR G9SR-BC201-RC G9SR-AD201-RC G9SR-EX031-T90-RC G9SP-N G9SP-N10S G9SP-N10D G9SP-N20S Programmable standalone controllers NX-S Integrated safety/ Programmable standalone controller 4 NX-SL3300 NX-SL3500 NX-SIH400 NX-SID800 NX-SOH200 NX-SOD400 F3S-TGR-N@R Specifications Mechanical data Indicator Operating distance Recommended setting gap Actuator approach speed Switching frequency Operating temperature Enclosure protection Cable material Mounting bolts Tightening torque for mounting bolts Shock resistance (IEC 68-2-27) Vibration resistance (IEC 68-2-6) Material – OFF  ON (Sao) ON  OFF (Sar) – Min. Max. Max. – Flying lead M12 connector M8 connector Flying lead M12 connector – Plastic housing None 10 mm (NBPR, NBMR: 8 mm) 20 mm (NBPR, NBMR: 12 mm) 5 mm 4 mm/s 1,000 mm/s 1 Hz –25 to 80°C IP69K IP67 IP67 PVC, 8 core, Ø 6 mm o.d. 250 mm, PVC, Ø 6 mm o.d. 2 × M4 Max. 1 Nm – 11 ms, 30 g – 10 to 55 Hz, 1 mm – Black polyester Stainless steel housing –25 to 105°C Stainless steel 316 Electrical data Sensor technology Serial switching Rated loads Contact release time Initial contact resistance Dielectric withstand Insulation resistance Switching current – – NC contacts Max. NO contacts Max. Max. Max. – – Min. Plastic housing Stainless steel housing Reed up to 6 pcs. in series 1 A @ 250 VAC (NMPR and NMHR: 0.5 A @ 250 VAC, NBPR and NBMR: 0.5 A @ 24 VDC) 0.2A @ 24VDC 2 ms 500 m 250 VAC 100 M 1 mA, 10 VDC Reliability data EN ISO 13849-1 EN 62061 PFHd B10d Proof test interval (Life) MTTFd (@ nop: 8 cycles per hour) Plastic housing Stainless steel housing up to PLe depending upon system architecture up to SIL3 depending upon system architecture 2.52 × 10-8 3.3 × 106 47 years 470 years Approved standards EN standards certified by TÜV Rheinland EN ISO13849-1 EN 62061 EN 60204-1 EN ISO 14119 EN/IEC 60947-5-3 UL 508, CSA C22.2 BS 5304 EN 1088 conformance 5 F3S-TGR-N@R Operating characteristics L -5 -4 -3 -2 -1 0 1 2 3 4 5 5 mm misalignment tolerance after setting Connection diagrams Cable version Pin No. Signal name red blue black white yellow green brown orange NC Channel 1 NC Channel 1 NC Channel 2 NC Channel 2 NO Channel Auxillary NO Channel Auxillary M1J8-Connector version (M12 male) Wire Pin No. Signal (Y92E-M12PURSH8S_M-L) (male side) 5 6 7 8 1 2 3 4 7 3 1 2 4 6 5 8 NC Channel 1 NC Channel 1 NC Channel 2 NC Channel 2 NO Channel Aux. NO Channel Aux. brown green blue white yellow pink grey red Note: If the auxiliary circuit is not fitted or not used then cut and discard the yellow/green or grey/red conductors. M8 connection diagram F3S-TGR-NMPR-20-08-_10-Connector version (M8 male, 2NC) Wire Pin No. Signal (XS3F-M8PVC4S_M-EU) (male side) 4 2 3 1 1 2 3 4 NC Channel 1 NC Channel 1 NC Channel 2 NC Channel 2 brown white blue black F3S-TGR-NMPR-11-08-_10-Connector version (M8 male, 1NC/1NO) Wire Pin No. Signal (XS3F-M8PVC4S_M-EU) (male side) 4 3 6 2 1 1 2 3 4 NO Channel 1 NO Channel 1 NC Channel 2 NC Channel 2 brown white blue black F3S-TGR-N@R Dimensions Elongated Sensor (Sensor/Actuator) F3S-TGR-NLPR 88 88 78 78 3.50 25 25 18.50 7 4.50 13 13 3 3 Ø 5.20 F3S-TGR-NLMR 88 88 78 78 18.50 3.50 25 25 7 4.60 14 14 3 3 Ø 5.40 Small Sensor (Sensor/Actuator) F3S-TGR-NSPR 13 50 13 22 4.50 4.50 25.50 4.20 3 20.50 20.50 25.50 4.20 3 50 22 F3S-TGR-NSMR 13 50 13 22 4.50 4.50 4.20 3 21 25.50 21 25.50 4.20 3 50 22 F3S-TGR-NSHR 13 25.50 22 13 20.50 20.50 25.50 50 Ø5 50 22 7 F3S-TGR-N@R F3S-TGR-NSFR 13 50 22 13 10 25.50 20.50 25.50 20.50 10 M4 × 10 mm Tapped hole 50 22 Miniature Sensor (Sensor/Actuator) F3S-TGR-NMPR TYPE : MPR (Left) 5 19 26 22 26 36 19 36 22 8.40 13 13 6 6 8.40 4.50 4.50 SWITCH ACTUATOR 26 19 19 36 26 5 36 M8 × 1mm F3S-TGR-NMPR (M8, 4pin connector) 6.50 22 22 8.40 6 4.50 Switch 6.20 13 13 6 8.40 4.50 Actuator F3S-TGR-NMHR TYPE : MMR-H (Left) 19 22 39 15 22 15 4.40 8 26 39 19 26 45 SWITCH 4.40 ACTUATOR F3S-TGR-N@R Barrel Sensor (Sensor/Actuator) F3S-TGR-NBPR F3S-TGR-NBMR Compact Sensor (Sensor/Actuator) F3S-TGR-NCPR Wide Sensor (Sensor/Actuator) F3S-TGR-NWPR 9 F3S-TGR-N@R Wiring examples (Single head connection up to category 4 acc. EN954-1) G9SE Single Sensor Application with G9SE-201 (up to Safety PLe acc. EN ISO 13849-1) +24 V GND Start T33 A1 F3S-TGR-N_R Actuator A2 T31 KM1 Feedbackloop Sensor G9SE-201 red blue black white green yellow KM2 T32 T11 T12 T21 T22 Auxiliary (NO) KM1 14 13 23 24 KM2 KM2 KM1 M +Us GND Series connection Application, up to 6 Sensors with G9SE-201 (up to Safety PLd acc. EN ISO 13849-1) F3S-TGR-N_R Actuator +24 V red blue black white yellow green red blue black white yellow green Start A1 T33 red blue black white yellow green A2 T31 KM1 Auxiliary (NO) Feedbackloop G9SE-201 T11 T12 T21 T22 KM2 T32 KM1 Auxiliary (NO) 13 14 +Us GND Auxiliary (NO) 23 24 KM2 KM1 10 GND Sensor KM2 M F3S-TGR-N@R G9SA Single Sensor Application with G9SA-301 (up to Safety PLe acc. EN ISO 13849-1) +24 V GND Start A1 F3S-TGR-N_R A2 T31 KM1 Actuator Feedbackloop Sensor G9SA-301 red blue black white yellow green KM2 T32 T11 T12 T21 T22 Auxiliary (NO) KM1 14 13 23 24 KM2 KM2 KM1 M +Us GND Series connection Application, up to 6 Sensors with G9SA-301 (up to Safety PLd acc. EN ISO 13849-1) F3S-TGR-N_R Actuator +24 V GND Sensor red blue black white yellow green red blue black white yellow green Start A1 A2 T31 KM1 Auxiliary (NO) G9SA-301 T11 T12 T21 T22 KM2 T32 KM1 Auxiliary (NO) 13 14 23 24 KM2 KM1 red blue black white yellow green Feedbackloop +Us KM2 M GND Auxiliary (NO) 11 F3S-TGR-N@R G9SP Single Sensor Application with G9SP (up to Safety PLe acc. EN ISO 13849-1) +24 V GND V0 G0 F3S-TGR-N_R Actuator Sensor G9SP red blue black white yellow green Test 0 In 0 Test 1 In 1 Auxiliary (NO) Series connection Application, up to 6 Sensors with G9SP (up to Safety PLd acc. EN ISO 13849-1) F3S-TGR-N_R Actuator red blue black white yellow green red blue black white yellow green red blue black white yellow green 12 +24 V GND Sensor V0 Auxiliary (NO) G0 G9SP Test 0 In 0 Test 1 In 1 Auxiliary (NO) Auxiliary (NO) F3S-TGR-N@R Safety Precautions !WARNING Be sure to turn OFF the power before performing wiring. Do not touch charge parts (e.g., terminals) while power is ON. Doing so may result in electric shock. Do not allow the actuator to come close to the switch with the door open. Doing so may cause machinery to start operating and may result in injury. Guard Stops !CAUTION Use guard stops in the way shown below to ensure that the switch and actuator do not make contact when the guard door is closed. Guard door Guard Stops Switch Keep actuators (magnets) away from magnetically sensitive equipment like PC harddisks, floppy disks etc. The magnetic field of the magnet will damage existing data. Actuator Application Precautions • Do not use the product in locations subject to explosive or flammable gases. • Do not use load currents exceeding the rated value. • Be sure to wire each conductor correctly. • Be sure to confirm correct operation after completing mounting and adjustment. • Do not drop or attempt to disassemble the product. • Be sure to use the correct combination of switch and actuator. • Use a power supply of the specified voltage. Do not use power supplies with large ripples or power supplies that intermittently generate incorrect voltages. • Capacitors are consumable and require regular maintenance and inspection. Installation Locations Do not install the product in the following locations. Doing so may result in product failure or malfunction. • Locations subject to direct sunlight • Locations subject to humidity levels outside the range 35% to 85% or subject to condensation due to extreme temperature changes • Locations subject to corrosive or flammable gases • Locations subject to shocks or vibration in excess of the product ratings • Locations subject to dust (including iron dust) or salts Take appropiate and sufficient countermeasures when using the product in the following locations. • Locations subject to static electricity or other forms of noise • Locations subject to possible exposure to radioactivity • Locations subject to power supply lines • It is advisable to mount the switches on non ferrous materials. The presence of ferrous material can effect switching sensitivity. Solvents Ensure that solvents, such as alcohol, thinner, trichloroethane, or gasoline do not adhere to the product. Solvents may cause markings to fade and components to deteriorate. min. 2 mm min. 5 mm (Standard Sensor) max. 4 mm (Elongated Sensor) Mounting Direction CORRECT CORRECT CORRECT INCORRECT Using for Hinged Doors On hinged doors, install the Sensor at an opening edge as shown below. INCORRECT CORRECT Mutual Interference If the switch and actuator are mounted in parallel, be sure to separate them by at least 25 mm, as shown below. 25 mm min. Switch Switch Actuator Actuator Guard door 13 F3S-TGR-N@R ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E18E-EN-04 14 In the interest of product improvement, specifications are subject to change without notice.
F3S-TGR-NMPR-20-05 价格&库存

很抱歉,暂时无法提供与“F3S-TGR-NMPR-20-05”相匹配的价格&库存,您可以联系我们找货

免费人工找货
F3S-TGR-NMPR-20-05
  •  国内价格
  • 1+1269.92578

库存:2