Magnetic non-contact safety switches
F3S-TGR-N@R
Reed non-contact switches monitor the status of guarding doors. Stainless steel
housing for high hygiene demands in the food industry are available.
• Based on reed technology
• Connect up to 6 switches in series
• Operates with all Omron safety controllers
• Operates behind stainless steel fittings
• Non-contact – no abrasion – no particles
• Compensation of mechanical tolerances
• Suitable for high pressure cleaning, CIP/SIP
processes due IP69K (pre-wired types)
• Conforms to safety categories up PLe acc.
EN ISO13849-1
Model Number Structure
F3S-TGR-N@@R-@@-@@
1 2
1. Type
L:
S:
M:
C:
W:
B:
3
4
Elongated Sensor
Small Sensor
Miniature Sensor
Compact Sensor
Wide Sensor
Barell Sensor
2. Housing Material
P:
Plastic Housing
M:
Stainless Steel Housing
H:
Hygienic designed Stainless Steel Housing
F:
Special Food Type Stainless Steel Housing
4. Cable Length/connection
05:
5 m Cable
05-R*:
5 m Cable exit to the right
10:
10 m Cable
10-R*:
10 m Cable, exit to the right
M1J8:
M12 male connector, 8 pin, fitted with 250 mm cable
M1J8-R*: M12 male connector, 8 pin, fitted with 250 mm cable
exit to the right
08-L10**: M8 male connector, 4 pin
08-R10**: M8 male connector, 4 pin, exit to the right
* only for F3S-TGR-NMPR and F3S-TGR-NMHR
** only for F3S-TGR-NMPR
3. Contact configuration
11*:
1 Normally Closed Contact (NC) +
1 Normally Open Contact (NO)
20*:
2 Normally Closed Contacts (NC)
21:
2 Normally Closed Contacts (NC) +
1 Normally Open Contact (NO)
* only existing for some NMPR-types
1
F3S-TGR-N@R
Ordering Information
Polyester Housing
Type
Elongated Sensors
Small Sensors
Cable connection
5 m pre-wired
10 m pre-wired
Compact Sensors
Wide Sensors
F3S-TGR-NLPR-21-M1J8
5 m pre-wired
10 m pre-wired
F3S-TGR-NSPR-21-05
F3S-TGR-NSPR-21-10
5 m pre-wired
10 m pre-wired
M12, 8 pin, fitted with 250 mm cable
5 m pre-wired, cable exit right
10 m pre-wired, cable exit right
M12, 8 pin, fitted with 250 mm cable exit right
M8, 4 pin, direct connector left side
M8, 4 pin, direct connector right side
M8, 4 pin, direct connector left side
M8, 4 pin, direct connector right side
5 m pre-wired
2NC/1NO
2NC
1NC/1NO
F3S-TGR-NSPR-21-M1J8
F3S-TGR-NMPR-21-05
F3S-TGR-NMPR-21-10
F3S-TGR-NMPR-21-M1J8
F3S-TGR-NMPR-21-05-R
F3S-TGR-NMPR-21-10-R
F3S-TGR-NMPR-21-M1J8-R
F3S-TGR-NMPR-20-08-L10
F3S-TGR-NMPR-20-08-R10
F3S-TGR-NMPR-11-08-L10
F3S-TGR-NMPR-11-08-R10
F3S-TGR-NCPR-21-05
10 m pre-wired
F3S-TGR-NCPR-21-10
5 m pre-wired
F3S-TGR-NWPR-21-05
10 m pre-wired
Barrel Sensors
Order code
F3S-TGR-NLPR-21-05
F3S-TGR-NLPR-21-10
M12, 8 pin, fitted with 250 mm cable
M12, 8 pin, fitted with 250 mm cable
Miniature Sensors
Contact configuration
2NC/1NO
F3S-TGR-NWPR-21-10
5 m pre-wired
10 m pre-wired
F3S-TGR-NBPR-21-05
F3S-TGR-NBPR-21-10
M12, 8 pin, fitted with 250 mm cable
F3S-TGR-NBPR-21-M1J8
Stainless steel housing
Type
Elongated Sensors
Cable connection
5 m pre-wired
10 m pre-wired
Contact configuration
M12, 8 pin, fitted with 250 mm cable
Small Sensors
Barrel Sensors
2
5 m pre-wired
10 m pre-wired
Order code
F3S-TGR-NLMR-21-05
F3S-TGR-NLMR-21-10
F3S-TGR-NLMR-21-M1J8
2NC/1NO
F3S-TGR-NSMR-21-05
F3S-TGR-NSMR-21-10
M12, 8 pin, fitted with 250 mm cable
F3S-TGR-NSMR-21-M1J8
5 m pre-wired
10 m pre-wired
F3S-TGR-NBMR-21-05
F3S-TGR-NBMR-21-10
M12, 8 pin, fitted with 250 mm cable
F3S-TGR-NBMR-21-M1J8
F3S-TGR-N@R
Hygienic and food types
Type
Small Sensors
Small Sensors
(Special food types)
Cable connection
5 m pre-wired
10 m pre-wired
Contact configuration
M12, 8 pin, fitted with 250 mm cable
F3S-TGR-NSHR-21-M1J8
5 m pre-wired
10 m pre-wired
F3S-TGR-NSFR-21-05
F3S-TGR-NSFR-21-10
M12, 8 pin, fitted with 250 mm cable
Miniature Sensors
Order code
F3S-TGR-NSHR-21-05
F3S-TGR-NSHR-21-10
2NC/1NO
5 m pre-wired
10 m pre-wired
M12, 8 pin, fitted with 250 mm cable
5 m pre-wired, cable exit right
10 m pre-wired, cable exit right
M12, 8 pin, fitted with 250 mm cable exit right
F3S-TGR-NSFR-21-M1J8
F3S-TGR-NMHR-21-05
F3S-TGR-NMHR-21-10
F3S-TGR-NMHR-21-M1J8
F3S-TGR-NMHR-21-05-R
F3S-TGR-NMHR-21-10-R
F3S-TGR-NMHR-21-M1J8-R
Accessories
Cables 8-pin
Cables 4-pin
Actuators
Mounting screws
Spacer (8 mm, Set of 2pcs.)*1
*1
2m
5m
10 m
25 m
2m
5m
10 m
25 m
for F3S-TGR-NLPR
for F3S-TGR-NSPR
for F3S-TGR-NMPR
for F3S-TGR-NCPR
for F3S-TGR-NWPR
for F3S-TGR-NBPR
for F3S-TGR-NLMR
for F3S-TGR-NSMR
for F3S-TGR-NBMR
for F3S-TGR-NSHR
for F3S-TGR-NSFR
for F3S-TGR-NMHR
Set of Torx safety screws
(M4, 4 × 30 mm, 4 × 20 mm,
4 × 10 mm; incl. washers and
Torx bit)
for Elongated Sensors
for Small Sensors
for Miniature Sensors
for Compact Sensors
for Wide Sensors
Order code
Y92E-M12PURSH8S2M-L
Y92E-M12PURSH8S5M-L
Y92E-M12PURSH8S10M-L
Y92E-M12PURSH8S25M-L
XS3F-M8PVC4S2M-EU
XS3F-M8PVC4S5M-EU
XS3F-M8PVC4S10M-EU
XS3F-M8PVC4S20M-EU
F39-TGR-NLPR-A
F39-TGR-NSPR-A
F39-TGR-NMPR-A
F39-TGR-NCPR-A
F39-TGR-NWPR-A
F39-TGR-NBPR-A
F39-TGR-NLMR-A
F39-TGR-NSMR-A
F39-TGR-NBMR-A
F39-TGR-NSHR-A
F39-TGR-NSFR-A
F39-TGR-NMHR-A
F39-TGR-N-SCREWS
F39-TGR-NLR-SPACER
F39-TGR-NSR-SPACER
F39-TGR-NMR-SPACER
F39-TGR-NCR-SPACER
F39-TGR-NWR-SPACER
Spacers are needed to prefent influences if switch is mounted on ferromagnetic background (e. g. reduced switching distance, EMC influences)
3
F3S-TGR-N@R
Control units
Order code
G9SE
G9SE-201
G9SE-401
G9SE-221-T05
G9SE-221-T30
G9SA
G9SA-301
G9SA-501
G9SA-321-T075
G9SA-321-T15
G9SA-321-T30
Safety relay units
G9SR
G9SR-BC201-RC
G9SR-AD201-RC
G9SR-EX031-T90-RC
G9SP-N
G9SP-N10S
G9SP-N10D
G9SP-N20S
Programmable standalone
controllers
NX-S
Integrated safety/
Programmable standalone
controller
4
NX-SL3300
NX-SL3500
NX-SIH400
NX-SID800
NX-SOH200
NX-SOD400
F3S-TGR-N@R
Specifications
Mechanical data
Indicator
Operating distance
Recommended setting gap
Actuator approach speed
Switching frequency
Operating temperature
Enclosure protection
Cable material
Mounting bolts
Tightening torque for
mounting bolts
Shock resistance
(IEC 68-2-27)
Vibration resistance
(IEC 68-2-6)
Material
–
OFF ON (Sao)
ON OFF (Sar)
–
Min.
Max.
Max.
–
Flying lead
M12 connector
M8 connector
Flying lead
M12 connector
–
Plastic housing
None
10 mm (NBPR, NBMR: 8 mm)
20 mm (NBPR, NBMR: 12 mm)
5 mm
4 mm/s
1,000 mm/s
1 Hz
–25 to 80°C
IP69K
IP67
IP67
PVC, 8 core, Ø 6 mm o.d.
250 mm, PVC, Ø 6 mm o.d.
2 × M4
Max.
1 Nm
–
11 ms, 30 g
–
10 to 55 Hz, 1 mm
–
Black polyester
Stainless steel housing
–25 to 105°C
Stainless steel 316
Electrical data
Sensor technology
Serial switching
Rated loads
Contact release time
Initial contact resistance
Dielectric withstand
Insulation resistance
Switching current
–
–
NC contacts Max.
NO contacts Max.
Max.
Max.
–
–
Min.
Plastic housing
Stainless steel housing
Reed
up to 6 pcs. in series
1 A @ 250 VAC (NMPR and NMHR: 0.5 A @ 250 VAC, NBPR and NBMR: 0.5 A @
24 VDC)
0.2A @ 24VDC
2 ms
500 m
250 VAC
100 M
1 mA, 10 VDC
Reliability data
EN ISO 13849-1
EN 62061
PFHd
B10d
Proof test interval (Life)
MTTFd (@ nop: 8 cycles per hour)
Plastic housing
Stainless steel housing
up to PLe depending upon system architecture
up to SIL3 depending upon system architecture
2.52 × 10-8
3.3 × 106
47 years
470 years
Approved standards
EN standards certified by TÜV Rheinland
EN ISO13849-1
EN 62061
EN 60204-1
EN ISO 14119
EN/IEC 60947-5-3
UL 508, CSA C22.2
BS 5304
EN 1088 conformance
5
F3S-TGR-N@R
Operating characteristics
L
-5
-4
-3
-2
-1
0
1
2
3
4
5
5 mm misalignment tolerance after setting
Connection diagrams
Cable version
Pin No.
Signal name
red
blue
black
white
yellow
green
brown
orange
NC Channel 1
NC Channel 1
NC Channel 2
NC Channel 2
NO Channel Auxillary
NO Channel Auxillary
M1J8-Connector version (M12 male)
Wire
Pin No.
Signal
(Y92E-M12PURSH8S_M-L)
(male side)
5
6
7
8
1
2
3
4 7
3
1
2
4
6
5
8
NC Channel 1
NC Channel 1
NC Channel 2
NC Channel 2
NO Channel Aux.
NO Channel Aux.
brown
green
blue
white
yellow
pink
grey
red
Note: If the auxiliary circuit is not fitted or not used then cut and discard the yellow/green or grey/red conductors.
M8 connection diagram
F3S-TGR-NMPR-20-08-_10-Connector version (M8 male, 2NC)
Wire
Pin No.
Signal
(XS3F-M8PVC4S_M-EU)
(male side)
4
2
3
1
1
2
3
4
NC Channel 1
NC Channel 1
NC Channel 2
NC Channel 2
brown
white
blue
black
F3S-TGR-NMPR-11-08-_10-Connector version (M8 male, 1NC/1NO)
Wire
Pin No.
Signal
(XS3F-M8PVC4S_M-EU)
(male side)
4
3
6
2
1
1
2
3
4
NO Channel 1
NO Channel 1
NC Channel 2
NC Channel 2
brown
white
blue
black
F3S-TGR-N@R
Dimensions
Elongated Sensor (Sensor/Actuator)
F3S-TGR-NLPR
88
88
78
78
3.50
25
25
18.50
7
4.50
13
13
3
3
Ø 5.20
F3S-TGR-NLMR
88
88
78
78
18.50
3.50
25
25
7
4.60
14
14
3
3
Ø 5.40
Small Sensor (Sensor/Actuator)
F3S-TGR-NSPR
13
50
13
22
4.50
4.50
25.50
4.20
3
20.50
20.50
25.50
4.20
3
50
22
F3S-TGR-NSMR
13
50
13
22
4.50
4.50
4.20
3
21
25.50
21
25.50
4.20
3
50
22
F3S-TGR-NSHR
13
25.50
22
13
20.50
20.50
25.50
50
Ø5
50
22
7
F3S-TGR-N@R
F3S-TGR-NSFR
13
50
22
13
10
25.50
20.50
25.50
20.50
10
M4 × 10 mm
Tapped hole
50
22
Miniature Sensor (Sensor/Actuator)
F3S-TGR-NMPR
TYPE : MPR (Left)
5
19
26
22
26
36
19
36
22
8.40
13
13
6
6
8.40
4.50
4.50
SWITCH
ACTUATOR
26
19
19
36
26
5
36
M8 × 1mm
F3S-TGR-NMPR (M8, 4pin connector)
6.50
22
22
8.40
6
4.50
Switch
6.20
13
13
6
8.40
4.50
Actuator
F3S-TGR-NMHR
TYPE : MMR-H (Left)
19
22
39
15
22
15
4.40
8
26
39
19
26
45
SWITCH
4.40
ACTUATOR
F3S-TGR-N@R
Barrel Sensor (Sensor/Actuator)
F3S-TGR-NBPR
F3S-TGR-NBMR
Compact Sensor (Sensor/Actuator)
F3S-TGR-NCPR
Wide Sensor (Sensor/Actuator)
F3S-TGR-NWPR
9
F3S-TGR-N@R
Wiring examples (Single head connection up to category 4 acc. EN954-1)
G9SE
Single Sensor Application with G9SE-201
(up to Safety PLe acc. EN ISO 13849-1)
+24 V
GND
Start
T33
A1
F3S-TGR-N_R
Actuator
A2
T31
KM1
Feedbackloop
Sensor
G9SE-201
red
blue
black
white
green
yellow
KM2
T32
T11
T12
T21
T22
Auxiliary (NO)
KM1
14
13
23
24
KM2
KM2
KM1
M
+Us
GND
Series connection Application, up to 6 Sensors with G9SE-201
(up to Safety PLd acc. EN ISO 13849-1)
F3S-TGR-N_R
Actuator
+24 V
red
blue
black
white
yellow
green
red
blue
black
white
yellow
green
Start
A1
T33
red
blue
black
white
yellow
green
A2
T31
KM1
Auxiliary
(NO)
Feedbackloop
G9SE-201
T11
T12
T21
T22
KM2
T32
KM1
Auxiliary
(NO)
13
14
+Us
GND
Auxiliary
(NO)
23
24
KM2
KM1
10
GND
Sensor
KM2
M
F3S-TGR-N@R
G9SA
Single Sensor Application with G9SA-301
(up to Safety PLe acc. EN ISO 13849-1)
+24 V
GND
Start
A1
F3S-TGR-N_R
A2
T31
KM1
Actuator
Feedbackloop
Sensor
G9SA-301
red
blue
black
white
yellow
green
KM2
T32
T11
T12
T21
T22
Auxiliary (NO)
KM1
14
13
23
24
KM2
KM2
KM1
M
+Us
GND
Series connection Application, up to 6 Sensors with G9SA-301
(up to Safety PLd acc. EN ISO 13849-1)
F3S-TGR-N_R
Actuator
+24 V
GND
Sensor
red
blue
black
white
yellow
green
red
blue
black
white
yellow
green
Start
A1
A2
T31
KM1
Auxiliary
(NO)
G9SA-301
T11
T12
T21
T22
KM2
T32
KM1
Auxiliary
(NO)
13
14
23
24
KM2
KM1
red
blue
black
white
yellow
green
Feedbackloop
+Us
KM2
M
GND
Auxiliary
(NO)
11
F3S-TGR-N@R
G9SP
Single Sensor Application with G9SP
(up to Safety PLe acc. EN ISO 13849-1)
+24 V
GND
V0
G0
F3S-TGR-N_R
Actuator
Sensor
G9SP
red
blue
black
white
yellow
green
Test 0
In 0
Test 1
In 1
Auxiliary (NO)
Series connection Application, up to 6 Sensors with G9SP
(up to Safety PLd acc. EN ISO 13849-1)
F3S-TGR-N_R
Actuator
red
blue
black
white
yellow
green
red
blue
black
white
yellow
green
red
blue
black
white
yellow
green
12
+24 V
GND
Sensor
V0
Auxiliary
(NO)
G0
G9SP
Test 0
In 0
Test 1
In 1
Auxiliary
(NO)
Auxiliary
(NO)
F3S-TGR-N@R
Safety Precautions
!WARNING
Be sure to turn OFF the power before performing wiring.
Do not touch charge parts (e.g., terminals) while power is
ON. Doing so may result in electric shock.
Do not allow the actuator to come close to the switch with
the door open. Doing so may cause machinery to start
operating and may result in injury.
Guard Stops
!CAUTION
Use guard stops in the way shown below to ensure that
the switch and actuator do not make contact when the
guard door is closed.
Guard door
Guard Stops
Switch
Keep actuators (magnets) away from magnetically sensitive equipment like PC harddisks, floppy disks etc. The
magnetic field of the magnet will damage existing data.
Actuator
Application Precautions
• Do not use the product in locations subject to explosive or
flammable gases.
• Do not use load currents exceeding the rated value.
• Be sure to wire each conductor correctly.
• Be sure to confirm correct operation after completing mounting and
adjustment.
• Do not drop or attempt to disassemble the product.
• Be sure to use the correct combination of switch and actuator.
• Use a power supply of the specified voltage. Do not use power
supplies with large ripples or power supplies that intermittently
generate incorrect voltages.
• Capacitors are consumable and require regular maintenance and
inspection.
Installation Locations
Do not install the product in the following locations. Doing so may
result in product failure or malfunction.
• Locations subject to direct sunlight
• Locations subject to humidity levels outside the range 35% to 85%
or subject to condensation due to extreme temperature changes
• Locations subject to corrosive or flammable gases
• Locations subject to shocks or vibration in excess of the product
ratings
• Locations subject to dust (including iron dust) or salts
Take appropiate and sufficient countermeasures when using the
product in the following locations.
• Locations subject to static electricity or other forms of noise
• Locations subject to possible exposure to radioactivity
• Locations subject to power supply lines
• It is advisable to mount the switches on non ferrous materials.
The presence of ferrous material can effect switching sensitivity.
Solvents
Ensure that solvents, such as alcohol, thinner, trichloroethane, or
gasoline do not adhere to the product. Solvents may cause markings
to fade and components to deteriorate.
min. 2 mm
min. 5 mm (Standard Sensor)
max. 4 mm (Elongated Sensor)
Mounting Direction
CORRECT
CORRECT
CORRECT
INCORRECT
Using for Hinged Doors
On hinged doors, install the Sensor at an opening edge as shown
below.
INCORRECT
CORRECT
Mutual Interference
If the switch and actuator are mounted in parallel, be sure to separate
them by at least 25 mm, as shown below.
25 mm min.
Switch
Switch
Actuator
Actuator
Guard door
13
F3S-TGR-N@R
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E18E-EN-04
14
In the interest of product improvement, specifications are subject to change without notice.