Safety Light Curtain
F3S-B
Safety Design for Category 2.
Suitable for
Detecting Human
Bodies in a
Dangerous Area
Features
• The F3S-B is a type 2 Safety Light curtain intended to be
used as or with the safety related parts of the control system
of a machine to category 2, 1 or B as defined in the European standard EN954-1.
• Compliance with IEC 61496-2, EN 61496-1 standards and
machine and EMC directive.
• Received certificates from Notified Bodies as Type 2 ESPE
(Electro-Sensitive-Protective-Equipment).
• UL/CSA approved.
• Pursuing safety with high level of safety design and FMEA.
• Series configuration of two units is possible.
F3S-B
F3S-B
• Units available with an axis pitch of 25 mm (hand protection), 50 mm (arm protection) or 75 mm (body protection) in
protective height ranging from 300 mm to 1650 mm.
• Human body detection system without a dedicated control
box.
• M12 Connector
G-31
F502-EN2-04.book Seite 32 Dienstag, 26. Juli 2005 5:48 17
Ordering Information
F3S-B M 36 2 P 12 - L
blank
M
S
Stand-alone
Master unit for series connection
Slave unit for series connection
blank
L
D
Complete set of emitter and receiver
Emitter unit only
Receiver unit only
36
No. of optical axis (4-66)
2
5
7
25 mm optical pitch
50 mm optical pitch
75 mm optical pitch
blank
12
Stand-alone or slave unit
No. of optical axis of the connected slave unit
for 25 mm optical pitch type: 12, 18, 24, or 30
for 50 mm optical pitch type: 06, 09, 12, or 15
for 75 mm optical pitch type: 04, 06, 08, or 10
blank
P
Slave unit
PNP outputs
Stand-alone
F3S-B122P
F3S-B182P
F3S-B242P
F3S-B302P
F3S-B362P
F3S-B422P
F3S-B482P
F3S-B542P
F3S-B602P
F3S-B662P
F3S-B065P
F3S-B095P
F3S-B125P
F3S-B155P
F3S-B185P
F3S-B215P
F3S-B245P
F3S-B275P
F3S-B305P
F3S-B335P
F3S-B047P
F3S-B067P
F3S-B087P
F3S-B107P
F3S-B127P
F3S-B147P
F3S-B167P
F3S-B187P
F3S-B207P
F3S-B227P
G-32
Master unit
F3S-BM122P##
F3S-BM182P##
F3S-BM242P##
F3S-BM302P##
F3S-BM362P##
F3S-BM422P##
F3S-BM482P##
F3S-BM542P##
F3S-BM602P##
F3S-BM662P##
F3S-BM065P##
F3S-BM095P##
F3S-BM125P##
F3S-BM155P##
F3S-BM185P##
F3S-BM215P##
F3S-BM245P##
F3S-BM275P##
F3S-BM305P##
F3S-BM335P##
F3S-BM047P##
F3S-BM067P##
F3S-BM087P##
F3S-BM107P##
F3S-BM127P##
F3S-BM147P##
F3S-BM167P##
F3S-BM187P##
F3S-BM207P##
F3S-BM227P##
Slave unit
F3S-BS122
F3S-BS182
F3S-BS242
F3S-BS302
F3S-BS065
F3S-BS095
F3S-BS125
F3S-BS155
F3S-BS047
F3S-BS067
F3S-BS087
F3S-BS107
-
Optical
resolution
30 mm
55 mm
80 mm
No. of
optical axes
12
18
24
30
36
42
48
54
60
66
6
9
12
15
18
21
24
27
30
33
4
6
8
10
12
14
16
18
20
22
Protective height
300 mm
450 mm
600 mm
750 mm
900 mm
1,050 mm
1,200 mm
1,350 mm
1,500 mm
1,650 mm
300 mm
450 mm
600 mm
750 mm
900 mm
1,050 mm
1,200 mm
1,350 mm
1,500 mm
1,650 mm
300 mm
450 mm
600 mm
750 mm
900 mm
1,050 mm
1,200 mm
1,350 mm
1,500 mm
1,650 mm
Weight (without
accessories)
0.9 kg
1.2 kg
1.5 kg
1.8 kg
2.1 kg
2.5 kg
2.8 kg
3.1 kg
3.4 kg
3.7 kg
0.9 kg
1.2 kg
1.5 kg
1.8 kg
2.1 kg
2.5 kg
2.8 kg
3.1 kg
3.4 kg
3.7 kg
0.9 kg
1.2 kg
1.5 kg
1.8 kg
2.1 kg
2.5 kg
2.8 kg
3.1 kg
3.4 kg
3.7 kg
Safety Sensors / Components
F502-EN2-04.book Seite 33 Dienstag, 26. Juli 2005 5:48 17
Nomenclature
Protective height
Series connection types
The F3S-B can detect in the area indicated by ”Protective
height” in the figure below. The protective height is from ”the
Optical-axis line mark above the indicator area” to ”the end of
the yellow metal case”.
When your application requires an additional protective zone,
for example, to prevent someone from staying behind a primary detection zone, the F3S-B may be connected in series.
The system consists of a master unit, a slave unit, and a series connection cable, type F39-JB1B.
The series connection allows up to 96 axes and 2.4 m of pro-
Optical-axis line mark
The center line for optical axes is indicated by the triangle
mark. This position is a reference line for measuring safety
distance.
No. of optical axes
Optical resolution
Receiver
Emitter
n
n-1
2
1
Protective
height
Limit position
for detection
tective height in total.
Series connection types have the same characteristics as a
stand-alone types. When the detection zone of the master
unit or that of the slave unit is interrupted, the outputs of the
master unit go to the OFF-state.
Optical- axis
pitch
Detection distance
Protective
height
Optical- axis
line mark
Slave unit
Stand-alone type
This is the most common configuration, and it is used to protect a hazardous part of a machine when approached from
one direction only.
Receiver
Series connection cable
Emitter
Protective
height
Master unit
Protective
height
Indicator area
Extension cable
F3S-B
Extension cable
F3S-B
Indicator area
Note: Slave unit does not have indicators.
Master unit and slave unit need to be ordered separately.
G-33
F502-EN2-04.book Seite 34 Dienstag, 26. Juli 2005 5:48 17
Rating and Performance
Type
No. of optical axes
Optical-axis pitch
Optical resolution
(Detection capability)
Protective height
Detection distance
Response time
Startup waiting time
Supply voltage: Vs
Current
consumption
Light source
Effective aperture angle
Operating mode
Control output
Instability output
Protection circuit
Start/restart
interlock function
External test function
Relay monitoring
function (optional)
Start interlock function
(optional)
Blanking function
(optional)
Indicator
Connection method
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength voltage
Degree of protection
Vibration resistance
Shock resistance
Materials
Size (cross section)
G-34
F3S-B###P*1
Stand-alone
F3S-BM###P## *1
F3S-BS###*1
Master unit for series connection Slave unit for series connection
12 to 66 6 to 33
4 to 22
12 to 66 6 to 33
4 to 22
12 to 30 6 to 15
4 to10
25 mm
50 mm
75 mm
25 mm
50 mm
75 mm
25 mm
50 mm
75 mm
Non-transparent: in diameter
30 mm
55 mm
80 mm
30 mm
55 mm
80 mm
30 mm
55 mm
80 mm
300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350 / 1,500 /
300 / 450 / 600 / 750 mm
1,650 mm
0.3 to 5.0 m, up to 8 m on request
ON to OFF: See table “Response Time”
OFF to ON*2: Default 100 ms (selectable with F39-U1E, 80 to 400 ms)
2 s max.
24 VDC ± 20% (including 5 Vp-p ripple)
400 mA max. (under no-load conditions)
Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.
Within ± 5° for the emitter and receiver at a detection distance of at least 3 m according to IEC
61496-2
Light ON
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension)
PNP transistor output (not safety-related control output),
activated during an insufficient light detection, failure detection and connection with F39-E1,
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension)
Output short-circuit protection, power supply reverse connection protection
Mode selection before power ON by connecting ”Interlock selection input” line to:
Active: No connection or 0 to 2.5 VDC, 3 mA max.
Inactive: Instability output line
Reset of start/restart interlock by connecting ”Interlock selection input” line to:
Interlock reset: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms
Mode selection by connecting ”External test input” line to:
Active: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms
Inactive: No connection or 0 to 2.5 VDC, 2 mA max.
Default inactive, selectable with F39-U1E
Relay monitoring input line with NC contact connected,
Available level: 17 VDC to Vs, 10 mA max.
Allowed relay delay time*3: Selectable between 20 and 300 ms
Termination when not selected: No connection or 0 to 2.5 VDC, 2 mA max.
Default inactive, selectable with F39-U1E
Default inactive, selectable with F39-U1E
See ”Indicators”
No indicators
For Extension cable: 8 pins, M12 connector
For Series connection cable: 6 pins, M12 connector
During operation: –10 to 55 °C (with no freezing)
During storage: –25 to 70 °C
During operation: 35 to 85 %RH (with no condensation)
During storage: 35 to 95 %RH
20 MΩ min. (at 500 VDC)
1,000 VAC 50/60 Hz for 1 min
IEC60529 IP65
Normal operation: 10 to 55 Hz, double-amplitude: 0.7mm, X, Y and Z directions 20 sweeps
Normal operation: 100 m/s2 [10 G], X, Y and Z directions: 1000 times
Case: Aluminum
Front cover: PMMA (acrylic resin)
End caps: PA6
30 x 40 mm
Safety Sensors / Components
F502-EN2-04.book Seite 35 Dienstag, 26. Juli 2005 5:48 17
F3S-B###P*1
Stand-alone
Type
F3S-BM###P## *1
F3S-BS###*1
Master unit for series connection Slave unit for series connection
Test rod*3, mounting brackets (top and bottom), mounting brackets (intermediate)*4, mounting
plates*5, Instruction manual*5
IEC(EN)61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
Accessories
Applicable standard
Note: 1 . For detailed type names and optical specifications, see „Type Naming Rule“
2 . Nominal value (set time). The accuracy is -0 ... +70% of the ON to OFF response time.
3 . Only with F3S-B###2P and BM###2P##.
4 . For the 1,050 mm protective height and longer types.
5 . Only with F3S-B###P# and BM##2P##.
Indicators
Optical- axis
line mark
IR-power indicator
(Orange)
POWER
INTERLOCK
EXT.TEST
BLANKING
ON-state indicator
(Green)
ON
Interlock indicator
(Yellow)
UNSTAB
External test /
blanking indicator
(Green)
Emitter
Receiver
OFF-state indicator
(Red)
OFF
IR-power indicator:
Interlock indicator:
External test/ blanking indicator:
ON-state indicator:
OFF-state indicator:
Lit when emitting.
Lit during start/restart interlock or start interlock.
Lit during external test. / Flashing when using blanking function.
Lit when receiving light.
Lit with interrupted light.
Flashing during connection with F39-E1 or with failure.
Lit with an insufficient light reception or failure.
Flashing during connection with F39-E1.
F3S-B
Instability indicator:
Instability indicator
(Orange)
F3S-B
G-35
F502-EN2-04.book Seite 36 Dienstag, 26. Juli 2005 5:48 17
Table of Response Time
Stand-alone type
Response time [ms ]
F3S-B122P
F3S-B182P
F3S-B242P
F3S-B302P
F3S-B362P
F3S-B422P
F3S-B482P
F3S-B542P
F3S-B602P
F3S-B662P
Response time [ms ]
20
20
20
23
27
30
34
37
41
45
F3S-B065P
F3S-B095P
F3S-B125P
F3S-B155P
F3S-B185P
F3S-B215P
F3S-B245P
F3S-B275P
F3S-B305P
F3S-B335P
20
20
20
20
20
21
22
24
26
28
Response time [ms ]
F3S-B047P
F3S-B067P
F3S-B087P
F3S-B107P
F3S-B127P
F3S-B147P
F3S-B167P
F3S-B187P
F3S-B207P
F3S-B227P
20
20
20
20
20
20
20
20
20
21
Series connection types
The following chart shows the response time of combinations of a master unit and a slave unit connected in series. For example,
the response time of the combination of F3S-BM122P30 and F3S-BS302 is 30 ms.
Slave unit F3SMaster unit
F3S-BM122P##
F3S-BM182P##
F3S-BM242P##
F3S-BM302P##
F3S-BM362P##
F3S-BM422P##
F3S-BM482P##
F3S-BM542P##
F3S-BM602P##
F3S-BM662P##
Slave unit F3SMaster unit
F3S-BM065P##
F3S-BM095P##
F3S-BM125P##
F3S-BM155P##
F3S-BM185P##
F3S-BM215P##
F3S-BM245P##
F3S-BM275P##
F3S-BM305P##
F3S-BM335P##
G-36
BS122
20
23
27
30
34
37
41
45
49
54
BS065
20
20
20
21
22
24
26
28
30
32
Response time [ms]
BS182
BS242
23
27
30
34
37
41
45
49
54
57
27
30
34
37
41
45
49
54
57
61
Response time [ms]
BS095
BS125
20
20
21
22
24
26
28
30
32
34
20
21
22
24
26
28
30
32
34
35
BS302
30
34
37
41
45
49
54
57
61
65
Slave unit F3SMaster unit
F3S-BM047P##
F3S-BM067P##
F3S-BM087P##
F3S-BM107P##
F3S-BM127P##
F3S-BM147P##
F3S-BM167P##
F3S-BM187P##
F3S-BM207P##
F3S-BM227P##
BS047
20
20
20
20
20
20
20
21
23
24
Response time [ms]
BS067
BS087
20
20
20
20
20
20
21
23
24
25
20
20
20
20
20
21
23
24
25
26
BS107
20
20
20
20
21
23
24
25
26
27
BS155
21
22
24
26
28
30
32
34
35
37
Safety Sensors / Components
F502-EN2-04.book Seite 37 Dienstag, 26. Juli 2005 5:48 17
Characteristic data
Operating Range
Parallel to Center Line of Lenses
300
300
200
200
100
Distance Y (mm)
Distance Y (mm)
F3S-B122P
Parapendicular to Center Line of Lenses
Y
0
X
-100
-200
100
Y
0
X
-100
-200
-300
-300
0
2
4
6
8
0
2
Distance X (m)
6
8
Parallel to Center Line of Lenses
300
300
200
200
100
Distance Y (mm)
Distance Y (mm)
F3S-B662P
Parapendicular to Center Line of Lenses
Y
0
X
-100
4
Distance X (m)
-200
-300
100
Y
0
X
-100
-200
-300
0
2
4
8
0
2
4
6
8
Distance X (m)
F3S-B
Distance X (m)
6
F3S-B
G-37
F502-EN2-04.book Seite 38 Dienstag, 26. Juli 2005 5:48 17
I/O Circuit Diagram
IR-light Interlock Ext. test/blanking
indicator indicator indicator
2
3
Grey
Main emitter
circuit
1
4
7
RS-485(B)
Green
White
Relay monitoring
input
6
RS-485(A)
+24 V
External test
input
5
Pink
Brown
Yellow
Interlock selection
input
Blue
0V
ON-state OFF-state Instability
indicator indicator indicator
2
Pink
Grey
3
6
Green
Control output 1
Main receiver
circuit
5
Brown
1
Control output 2
4
G-38
Load
Yellow
Instability
output
7
Load
White
Load
Blue
Safety Sensors / Components
F502-EN2-04.book Seite 39 Dienstag, 26. Juli 2005 5:48 17
Dimensions
Safety Light Curtain
F3S-B
Type
A
Protective
height
F3S-B122, -B065, -B047
F3S-B182, -B095, -B067
F3S-B242, -B125, -B087
F3S-B302, -B155, -B107
F3S-B362, -B185, -B127
F3S-B422, -B215, -B147
F3S-B482, -B245, -B167
F3S-B542, -B275, -B187
F3S-B602, -B305, -B207
F3S-B662, -B335, -B227
3
9.5
M12 connector
300
450
600
750
900
1050
1200
1350
1500
1650
343
493
643
793
943
1093
1243
1393
1543
1693
Note:All units are in Millimeters unless otherwise indicated.
10.5
3
34
B
A (Protective height)
Master unit
B
Full length
40.3
30
M12 connector
Accessoires
Mounting Bracket (Top and Bottom)
Mounting Plate
Only supplied with types which have a protective height of 1050 mm or longer (Including intermediate brackets). Only needed for rear mounting
5.5
22
R2.75
16 12
20
42.74
7
36.5
R1.75
F3S-B
20˚
5
20
Ø 25.5
35˚
3
3.5
6.25
4
22.5
28.74
46
30
5.5
R2.75
12
2
36
F3S-B
R4.5
G-39
F502-EN2-04.book Seite 40 Dienstag, 26. Juli 2005 5:48 17
Intermediate Mounting Bracket
Only needed for types which have a protective height of 1050 mm or longer
Mounting screw for sensor (M6x8)
Flat intermediate bracket
Rubber
U-shaped intermediate bracket
Fixing screw for bracket (M4x10)
L-shaped intermediate bracket
Options (Order Separately)
Extension Cable
(Set of 2: Emitter > gray, Receiver > black)
F39-JB1A (L = 3 m)
F39-JB2A (L = 7 m)
F39-JB3A (L = 10 m)
42
L
Ø 15
R o u n d v in y l- in s u la te d c o r d
5 .7 m m d ia . ( 3 2 /0 .1 m m d ia .) 8 c o r e s
M12
U n it: m m
Series Connection Cable
(Set of 2: Emitter > gray, Receiver > black)
F39-JB1B
48.5
300
Ø 15
M12
Unit: mm
Optional Function Kit
F39-EU1E
This set includes the following items:
· F39-U1E OptionalFunction Software
· F39-E1 Interface Unit
· F39-JB1C Interface Cable
The F39-U1E Optional Function Software is the WINDOWS®
-based software for use with the F39-E1 Interface Unit to program the F3S-B Safety Light Curtain, and provided with one
3.5 inch floppy disk. This software has the following features:
· Set the following functions to the F3S-B
- Start interlock function
- Relay monitoring function
- Blanking function
· Display each axis and each input line condition of the F3S-B
· Change the ON delay time
G-40
Note: The F3S-B is not in normal operation during connection with the F39-E1.
The control outputs are held in their OFF-state. For detailed information
please refer to “Details of F39-EU1E” in this data sheet.
!WARNING
After setting the blanking function, check that the F3S-B detects a test
rod at any position in the F3S-B detection zone through which a person reaches the hazardous part of the machine. If any positions are
found by check above, install protective structures to there to prevent
intrusion which F3S-B can not detect. Failure to do so may result in
serious injury.
Perform the installation check and the periodical inspection described
in the F3S-B manual.
Disconnect the outputs of the F3S-B from the load when programming it using the F39-U1E software and with F39-E1 interface unit.
Failure to do so may result in serious injury.
Do not connect the F39-E1 to a power supply with a voltage higher than
24 VDC +20 %. Do not connect the F39-E1 to an AC power supply.
Safety Sensors / Components
F502-EN2-04.book Seite 41 Dienstag, 26. Juli 2005 5:48 17
Installation
Wiring
Disconnect all sources of power before wiring the F3S-B to a
machine.
· Connect the emitter extension cable (F39-JBxA-L optional,
gray color outer jacket) to the emitter. (The emitter uses
gray color plastic caps.)
· Connect the receiver extension cable (F39-JBxA-D optional, black color outer jacket) to the receiver. (The receiver
unit uses black color plastic caps.)
· Connect the 0 V line of the power supply directly to protective earth (PE).
Note: Note:Be sure to wire correctly. Failure to do so may damage the F3S-B.
Front View
7
1
2
6
8
3
5
4
Pin No.
Signal Name
Receiver
Emitter
Wire Color
of Extension Cable
1
2
3
4
5
6
7
8
Control output 2
24 VDC
Control output 1
Instability output
RS-485 (A)
RS-485 (B)
0V
N.C. / reserved*1
Relay monitoring input
24 VDC
External test input
Interlock selection input
RS-485 (A)
RS-485 (B)
0V
N.C. / reserved
White
Brown
Green
Yellow
Grey
Pink
Blue
Red
*1. N.C. / reserved: do not connect
Emitter
Receiver
E1:
S1:
K1, K2:
K3:
24 VDC Power supply
External test switch
Relay
Relay to indicate unstable condition
RS-485(A) (Grey 5)
Output 2 (White 1)
Output 1 (Green 3)
0 V (Blue 7)
24 VDC (Brown 2)
Instability (Yellow 4)
Interlock selection (Yellow 4)
0 V (Blue 7)
24 VDC (Brown 2)
Ext. test (Green 3)
Relay monitoring (White 1)
RS-485(B) (Pink 6)
K1
F3S-B
S1
K2
E1
K3
F3S-B
G-41
F502-EN2-04.book Seite 42 Dienstag, 26. Juli 2005 5:48 17
When using START/RESTART FUNCTION
Emitter
When using optional RELAY MONITORING FUNCTION
Emitter
Receiver
0 V (Blue 7)
k1
24 VDC (Brown 2)
Ext. test (Green 3)
0 V (Blue 7)
24 VDC (Brown 2)
Relay monitoring (White 1)
RS-485(B) (Pink 6)
Instability (Yellow 4)
S2
Interlock selection (Yellow 4)
0 V (Blue 7)
24 VDC (Brown 2)
RS-485(A) (Grey 5)
k2
S1
E1
E1
K3
k1, k2: Auxiliary contact to moni
tor the condition of the final relay
S2: Restart interlock reset switch
Details of F39-EU1E Optional Function Kit
1. Installation
1.1 Preparation
· F39-JB1C Interface cable 5 m cable length, M8 connector
(4 pins)
!WARNING
Perform the installation check and the periodical inspection
described in the F3S-B manual.
Do not disassemble, repair or modify the F39-E1.
Do not use the F39-E1 in flammable or explosive environ-
30.5
5000
Ø 15
Round vinyl-insulated cord
5 mm dia. (32/0.1 mm dia.) 4 cores
ments.
To use the F39-U1E software, the following items are necessary.
· Personal Computer (not included)
- Windows® 95, Windows® 98, or Windows NT®
- 133MHz Pentium® processor or better
- 32MB RAM or higher for Windows® 95 and Windows® 98
- 64MB RAM or higher for Windows NT®
- A 115kBd RS-232 serial interface port or better
· F39-E1 Interface Unit
Unit : mm
· RS-232C cable (not included)
1.2 Component Names and Functions of the F39-E1 Interface Unit
SEND to RS-485 indicator (Red)
SEND to RS-232C indicator (Yellow)
M8 Connector (RS-485)
9pin D-Sub Connector
(RS-232C)
114
35
Communication indicator (Green)
8
60
G-42
Unit : mm
SEND to RS-485 Indicator (Red)
Lit when the F39-E1 sends data to the F3S-B via RS-485.
SEND to RS-232C Indicator (Yellow)
Lit when the F39-E1 sends data to the PC via RS-232C.
COMMUNICATION Indicator (Green)
Flashing during communication between the F3S-B and the
F39-E1.
Safety Sensors / Components
F502-EN2-04.book Seite 43 Dienstag, 26. Juli 2005 5:48 17
Start/Restart interlock is a function which is selected by wiring.
Refer to the instruction manual of the F3S-B for more detailed
information.
!WARNING
Disconnect the outputs of the F3S-B from the load when programming it using the F39-U1E software and with F39-E1 interface unit.
Failure to do so may result in serious injury.
Do not connect the F39-E1 to a power supply with a voltage higher than
24 VDC +20 %.
Do not connect the F39-E1 to an AC power supply.
1.3.1 Wiring Diagram
F3S- B
F39-U1E
Emitter
Receiver
PC
RS-232C
No.1 axis
RS-485(A) (Grey 5)
Open Output 1 (Green 3)
Open Output 2 (White 1)
0V (Bluie 7)
24 VDC (Braun 2)
24 VDC (Braun 2)
F39- JB1C
0V (Bluie 7)
F39-E1
Note 1
RS-485(B) (Pink 6)
Note 1
+24 V (Brown 1)
0 V (Blue 3)
RS- 485(A) (Black 4)
RS- 485(B) (White 2)
Note 1: See the instruction manual of F3S-B for wiring
1.3.2 Wiring Procedure
1. Connect the F3S-B (see the instruction manual of the F3SB for wiring.)
2. Connect the Interface cable (F39-JB1C) to the Interface
unit (F39-E1).
3. Connect the 4 wires of the Interface cable to each appropriate line of the F3S-B.
4. Connect an RS-232C cable to the PC and the Interface
unit.
1.4 Software-Installation
Copy the file „F39-U1E_ver#.#.exe“ and F39-U1E_ver#.#dat
from the enclosed 3.5-inch floppy disk onto the hard disk of
the PC.
2.2 Relay Monitoring
MPCEs (Machine Primary Control Elements) are usually relays or contactors used to control hazardous movement directly. The state of the MPCEs can be checked with the Relay
monitoring function.
A voltage of 17 VDC to Vs (Supplied voltage to F3S-B) has to
be applied to the Relay monitoring input through the NC contacts of the MPCEs when the F3S-B control outputs are in the
OFF-state (see the F3S-B manual for wiring information). To
ensure this logic relation, the MPCEs must be safety approved types, with forcibly guided contacts.
Allowed Relay Delay Time
The allowed relay delay time can be set between 20 and 300
ms. This delay time has to be set at least 20 milliseconds
shorter than the Outputs ON delay time.
2.3 Outputs ON Delay
You can set the ON delay time of control outputs between 80
and 400 ms. This corresponds to the time which the control
outputs go to ON-state after the detection zone is not interrupted.
Note: 1 . When the Relay monitoring function is also used, the ON delay time
must meet the formula below.
2 . ON delay time Allowed relay delay time + 20 ms After the Relay monitoring function is set, if the ON delay time does not meet the above
formula, the ON delay time will be changed automatically into ”Allowed
relay delay time” + 20 ms.
2.4 Blanking
With the Blanking function, one or more axes can be disabled.
This function is useful in an application where a part of the
F3S-B detection zone is always interrupted. The Manual-setting and the Teaching-setting are available to select the
blanked axes.
Note: 1 . In the case the blanked zone is not filled with structure completely and
remains some opening, the opening must be filled with the protective
structure.
2 . All axes can not be disabled. At least one axis needs to be active.
F3S-B
1.3 Hardware Connection
2. Function Description
2.1 Start Interlock
When the Start interlock function is used, the F3S-B does not
go to the ON-state automatically after power ON. Interrupting
one or more axes resets the start interlock condition of the
F3S-B then starts normal operation. The duration of the interruption must be equal or shorter as defined in the „Max. interruption time (sec)“.
Max. Interruption Time
The max interruption time can be set between 0.3 and 2 s.
Note: In the case both the Start interlock and the Start/restart interlock are selected, only the Start/restart interlock will be activate.
F3S-B
G-43
F502-EN2-04.book Seite 44 Dienstag, 26. Juli 2005 5:48 17
3. Ratings and Performance
Type
F39-E1 Interface unit
Supply voltage
Current Consumption
Interface
Indicator
Connection method
24 VDC ± 20% (including 5 Vp-p ripple)
120 mA max.
RS-232C interface, RS-485 interface
See 1-2
RS-485: 4pins, M 8 connector
RS-232C: D-SUB connector, 9 pins
RS 485 protection against wrong wiring
During operation: –10 to 55° C (with no freezing)
During storage: –25 to 70° C
During operation : 35 to 85% RH (with no condensation)
During storage: 35 to 95% RH
20 MΩ min. (at 500 VDC)
500 VAC 50/60 Hz for 1 min.
IEC60529 IP20
Normal operation: 150 m/s2 [15 G], ±X, ±Y and ±Z directions: 3 times
Normal operation: 10 to 55 Hz, double-amplitude: 0.3mm, X, Y and Z directions: 10 sweeps
RS-485 cable: 5 m (4 pin 0.25 mm2)
RS-232C cable: Standard
Case: Aluminum
122 x 60 x 35 mm
EMC Directive
Protection circuit
Ambient Temperature
Ambient Humidity
Ambient Humidity
Insulation Resistance
Dielectric strength voltage
Degree of Protection
Shock resistance
Vibration resistance
Cable length
Materials
Size
Conformity
G-44
Safety Sensors / Components
F502-EN2-04.book Seite 45 Dienstag, 26. Juli 2005 5:48 17
Precautions
!WARNING
1. Do not use the F3S-B on machines that can not be stopped by electrical control in case of an emergency.
2. Do not use the F3S-B in flammable or explosive environments
3. Always maintain the safety distance between F3S-B and a hazardous part of the machine. Serious injury may result if the machine does not stop before someone reaches the hazardous part.
4. Install protective structures around a machine so that you must pass through the detection zone to reach a hazardous part of
the machine.
5. Install F3S-B so that some parts of the operator’s body remain in the detection zone at all times when the operator works in the
hazardous area.
6. Failure to do so may result in serious injury.
Correct installation
Incorrect installation
A hazardous part of a machine can be
reached only by passing through the sensor detection zone.
A hazardous part of the machine can be
reached without passing through the sensor detected zone.
Some part of the operator’s body remains
in the detection zone while they are working.
A worker is between the sensor detection
zone and a hazardous part of a machine.
!WARNING
1. Be sure to install the F3S-B to minimize the effects of reflections from reflective surfaces. Failures to do so will create an inability
to detect and may result in serious injury
2. Install the F3S-B with a minimum distance D as shown below form the reflective surface (highly reflective surfaces) like metal
walls, floors, ceilings, and work pieces.
Reflecting ceiling
D
Emitter
Reflecting surface
Receiver
D
Detection zone
5˚
5˚
L
Emitter
D
Receiver
F3S-B
L
Reflecting floor
Distance between emitter and receiver (detection distance L)
Minimum installation distance D
0.3 to 3 m
3 to 5 m
0.26 m
L x tan 5° = L x 0.088 (m)
F3S-B
G-45
F502-EN2-04.book Seite 46 Dienstag, 26. Juli 2005 5:48 17
!WARNING
When using multiple sets of the F3S-B, install them so that mutual interference is not incurred.
RS-485
Receiver 1
Emitter 1
Receiver 2
(Incorrect)
Emitter 2
RS-485
Emitter 2
Receiver 2
Emitter 1
Receiver 1
(Incorrect)
(Incorrect)
Emitter 1
Receiver 1
RS-485
Emitter 2
Receiver 2
Alternate emitters and receivers
Correct installations are shown below to prevent mutual interference.
Emitter 1
Receiver 2
Emitter 2
RS-485
Receiver 2
RS-485
(Correct)
Emitter 2
Emitter 1
Receiver 1
RS-485
Receiver 1
(Correct)
(Correct)
Emitter 1
Receiver 1
Emitter 2
Receiver 2
RS-485
RS-485
G-46
Receiver 2
Emitter 2
Emitter 1
Receiver 1
(Correct)
RS-485
Safety Sensors / Components
F502-EN2-04.book Seite 47 Dienstag, 26. Juli 2005 5:48 17
!WARNING
1. The F3S-B is a TYPE 2 Electro-sensitive protective equipment, intended to be used as or with the safety related part
of control system to category 2, 1 or B as defined in the European standard EN954-1.
Do not use the F3S-B in category 3 or 4 systems.
2. A qualified person, as determind by local regulations, must
confirm that installation, inspection and maintenance are
implemented correctly.
3. Do not short the output lines to the +24 V line. Doing so will
cause the output to be always ON, creating a hazardous situation.
4. Do not connect the F3S-B to a power supply with voltage
higher than 24 VDC + 20%. Do not connect the F3S-B to an
AC power supply.
5. Be sure to conduct inspections regularly.
6. The F3S-B cannot be used in applications where hazardous projectiles may exit the protected zone.
7. Do not disassemble, repair or modify the F3S-B.
8. DC power supply units must satisfy all of the conditions below so that the F3S-B can comply with the applicable standards IEC 61496-1 and UL 508.
(4.) The power supply automatically resets overcurrent
protection characteristics (voltage drop).
(5.) The power supply maintains an output holding time of
at least 20 ms.
(6.) FG (frame ground terminal) must be connected to PE
(protective earth) when using a commercially available
switching regulator.
(7.) The power supply must have output characterisitics required for the power source for Class 2 Circuit or Limited Voltage / Current Circuit as defined in UL508.
(8.) The power supply must conform to regulatory requirements and standards, regarding EMC and electrical
equipment safety, of the country where the F3S-B is installed and where machinery will be operated, for example: The EMC Directive (industrial environment)
and the Low Voltage Directive in EU.
9. Do not use the F3S-B in a direct retroreflective configuration. Otherwise detection may fail.
F3S-B
(1.) The power supply voltage must be within rating
(24 VDC ± 20%).
(2.) The power supply is connected only to the F3S-B and
to the electro-sensitive protective function of the F3SB, such as a safety controller and muting sensors, and
it has enough rated current for all the devices.
(3.) The power supply uses double or reinforced insulation
between the primary and secondary circuits.
F3S-B
G-47
F502-EN2-04.book Seite 48 Dienstag, 26. Juli 2005 5:48 17
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E503-E2-01-X
G-48
In the interest of product improvement, specifications are subject to change without notice.
Safety Sensors / Components