Safety Light Curtains F3SJ-A F3SJA Rev. 2.12 Safety Light Curtains D • Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) • Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent on minimum object resolution and protected height • Protected heights: 14 mm protected heights from 245 to 1631 mm (9.6 to 64 in.), 20 mm, 25 mm and 30 mm protected heights from 245 to 2495 mm (9.6 to 98 in.), 55 mm from 270 to 2470 mm (10.6 to 97 in.) • Very compact size – 30 x 24 mm (1.18 x 0.94 in.) • Cascaded designs possible – 4 segments, up to 400 beams • Partial muting and position detection muting • Cross-talk prevention Description Position Detection Muting Function Warning Zone Function Position Detection Muting Function is used in applications where the workpiece is set in position each time by an operator, and a turntable or positioning robot then moves the workpiece to the area where the work is performed. A limit switch or other means is used to detect when the robot is in a safe position and muting is then applied. With the F3SJ-A, part of the detection zone can be used as warning zone to generate an alarm when someone approaches the danger zone. If the person then enters the danger zone the F3SJ-A will send a stop signal to the guarded machine. In addition, the auxiliary output can be used to activate a flashing lamp to alert the person in the warning zone. The detection zone for a single F3SJ-A can be divided into two zones or set a single warning zone for multiple, cascaded F3SJ-A units. Dividing the zone between series-connected sensors Detection zone Partial Muting Function Muting temporarily disables the F3SJ-A when an object must pass through the detection zone, such as when supplying a workpiece to your equipment. The F3SJ-A beams Partial muting continue to guard all increases the level of areas except for where safety by only muting the workpiece passes through. the beams of the safety light curtain where the workpiece passes through, while preventing muting in all other areas. Warning zone Only the beams of the safety light curtain interrupted by the workpiece are muted. D36 Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com This datasheet has been downloaded from http://www.digchip.com at this page F3SJ-A Safety Light Curtains SD Manager Software Using the SD Manager software, all features of the F3SJ-A can be set and checked. Features include: • Display of system specifications: – Model – Number of beams – Minimum object resolution – Response time • Settings for: – Fixed blanking – Floating blanking – Warning zone configuration – Muting – Both partial and position detection – External indicator function – Auxiliary outputs – EDM parameters – Operating range • Monitoring of received and ambient light intensity • Maintenance information: – Power on time – OSSD switching frequency • Recovery of settings • Safety distance calculations based on parameters for connected system “SD Manager” PC Setting Software F39-GWUM “SD Manager” PC Setting Software F3SJ-A To a USB terminal Branch Connector Connection Cable All parameters can be set and the system status can be checked with a personal computer. In addition to making it easy to monitor the beam alignment, the ambient incident light intensity can be displayed in bar graph form for an easy check of the system status. ● Beam alignment is easier. ● The ambient incident light intensity can be checked. Beam Alignment is Easier The incident light level can be displayed in a bar graph for each beam. Setting Console When you don’t want to take a computer into the field with you the F39-MC21 setting console is a convenient way to set parameters and check the system status. The incident light level can be displayed in a bar graph for each beam. Applications With built-in muting and blanking functions, the F3SJ-A can be employed in a wide variety of applications from robotic work cells to small machines. The potential for cascaded design and a broad selection of minimum object resolutions adds to this versatility. D The incident light level when the light emission of the Safety Light Curtain is stopped is displayed in a bar graph. Selecting the Best Configuration Space Efficient and Low Cost The built-in external device monitoring function eliminates the need for a safety relay unit. No Safety Relay Unit F39-JC®A G7SA Contactor Motor Reduced Wiring and Easy Maintenance Cables with connectors on both ends simplify connections and prevent wiring errors. Connector Type F39-JC®B F3SP-B1P Dedicated controller Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Contactor For the Latest Information On the Internet: www.sti.com Motor D37 F3SJ-A Safety Light Curtains Specifications Performance Resolution: Protected Height: Operating Range: Effective Aperture Angle: Response Time: D Safety Output Rating: Auxiliary (Non-Safety) Output Ratings: Light Source: Indicators: Mechanical Enclosure: Cable Length: Transmitter and Receiver Cable Connections: Electrical Power Supply: Environmental Protection Rating: Operating Temperature: Storage Temperature: Relative Humidity: Vibration: Shock: Approvals 14 mm, 20 mm, 25 mm, 30 mm, 55 mm 14 mm – 245 to 1631 mm (9.6 to 64.2 in.) 20 mm, 25 mm and 30 mm – 245 to 2495 mm (9.6 to 98.2 in.) 55 mm – 270 to 2470 mm (10.6 to 97.2 in.) 0.2 to 9 m for all protective heights up to 1640 mm (64.6 in.) 0.2 to 7 m for all protective heights longer than 1640 mm (64.6 in.): ±2.5° maximum, transmitter and receiver at operating range greater than 3 m (9.8 ft.) For 14 mm resolution systems up to 983 mm (38.7 in.) protected height ≤17.5 ms For 14 mm resolution systems above 983 mm (38.7 in.) protected height ≤25 ms For 20 mm resolution systems up to 1205 mm (47.4 in.) protected height ≤15 ms For 20 mm resolution systems above 1205 mm (47.4 in.) protected height ≤22.5ms For 25 mm resolution systems up to 1600 mm (63.0 in.) protected height ≤15 ms For 25 mm resolution systems above 1600 mm (63.0 in.) protected height ≤20.0ms For 30 mm resolution systems, all protected heights ≤17.5 ms For 55 mm resolution systems, all protected heights ≤13 ms Two 24 VDC PNP outputs sourcing 300 mA max. One 24 VDC PNP output sourcing 300 mA max. Infrared LED, 870 nm Transmitter: 5 LED Light Level Indicators, 3 LED Error Indicators, Power, Interlock, EDM, Blanking/Test Receiver: 5 LED Light Level Indicators, 3 LED Error Indicators, Machine Run, Machine Stop Anodized aluminum housing Optional cables are available up to 20 m (65.6 ft.) in length M12, 8-pin 24 VDC ± 20% IP65 -10 to 55°C (14 to 131°F) -30 to 70°C (-22 to 158°F) 35 to 85% non-condensing 10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions 100 m/s2, 1000 times each in X, Y and Z directions ESPE Type 4 (IEC 61496-1/ -2) Category 4 / PL e (EN ISO 13849-1) SIL3 / SIL3 CL3 (IEC 61508)UL508, UL1998, CAN/CSA-C22.2 No. 14, CAN/CSA-C22.2 No. 0.8 Specifications are subject to change without notice. F3SP-B1P Control Unit Power Supply Voltage: 24 VDC ±10% Power Consumption: DC1.7 W max (not including sensor’s current consumption) Operation Time: 100 ms max. (not including the sensor’s response time) Response Time: 10 ms max. (not including the sensor’s response time) Relay Output Number of Contacts: 3 N.O., 1 N.C. Rated Load: 250 VAC 5 A (cos = 1); 30 VDC 5 A L/R = 0 ms Rated Current: 5A Connection Type Between Sensors: M12 connector (8-pin) Others: Terminal block Weight: Approx. 280 g (9.9 oz.) Specifications are subject to change without notice. D38 Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com F3SJ-A Safety Light Curtains Wiring Wiring for Single F3SJ-A Application Detection of a welded relay contact is possible without a controller relay unit. Emitter • Manual reset mode • Using external device monitoring function Receiver D F39-JC@A-L F39-JC@A-D KM1 KM2 Shield 0 V (Blue) KM1 Control output 2 (White) Control output 1 (Green) Auxiliary output 1 (Yellow) External device monitoring input (Red) Communication line (−) (Pink) KM4 +24 V (Brown) +24 V (Brown) Interlock selection input (White) Reset input (Yellow) Test input (Green) S2 S1 Auxiliary output 2 (Red) 0 V (Blue) Shield Communication line (+) (Gray) KM1 KM2 KM2 KM3 +24 VDC IN OUT M E1 0V PLC Light incident Light interrupted External test switch (S1) Reset switch (S2) Control output KM1,KM2 N.O. contact KM1,KM2 N.C. contact PLC input (See note.) PLC output Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com D39 F3SJ-A Safety Light Curtains Dimensions (mm) 2-Top/bottom mounting brackets 5.5 2-Mounting holes 30 20 Mounting Screw Holes (13.75) 4-M5 20 16.5 1 3.75 6.25 30 24 D 31 22 7 Intermediate mounting bracket 22 2-M5 5.5 B D 53 A B 42 42 C (Protective height) 2-Mounting holes Beam 10 E 4-Mounting holes 37 300 6 dia. 13.75 6.5 dia. 2-Mounting holes 43 15 dia. E 9 dia. M12 Waterproof connector How to Calculate Your System Dimensions: C (protective height) = 4-digit number in the table A = C + 74 B = C + 46.5 D = C - 20 E = see chart below 26 46 Number of Protective Height Intermediate Brackets 245 to 596 mm (9.6 to 23.5 in.) 0 600 to 1130 mm (23.6 to 44.5 in.) 1 1136 to 1658 mm (44.7 to 65.3 in.) 2 1660 to 2180 mm (65.4 to 85.8 in.) 3 2195 to 2500 mm (86.4 to 98.4 in.) 4 *Use E = 530 or less when none of the E values shown above are used. D40 Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 E* — E = B/2 E = B/3 E = B/4 E = B/5 For the Latest Information On the Internet: www.sti.com F3SJ-A Safety Light Curtains Ordering The minimum components required for an F3SJ-A system are a emitter receiver set and a set of single or double-ended connector cables. See the table below for an overview of the versions available. The pages which follow provide specific part numbers and accessory descriptions. Safety Light Curtain F3SJ-A Designator Protection Detection Beam Gap Operating Range No. of Beams F3SJ-A££££P141 Finger 14 mm 9 mm 0.2 to 9 m (0.7 to 29.5 ft.) 26 to 197 F3SJ-A££££P201 Finger/Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 F3SJ-A££££P201 Finger/Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 F3SJ-A££££P20-TS2 Finger/Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 F3SJ-A££££P20-TS2 Finger/Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 F3SJ-A££££P251 Hand 25 mm 20 mm 0.2 to 9 m (0.7 to 29.5 ft.) 13 to 79 F3SJ-A££££P251 Hand 25 mm 20 mm 0.2 to 7 m (0.7 to 23.0 ft.) 87 to 125 F3SJ-A££££P25-TS2 Hand 25 mm 20 mm 0.2 to 9 m (0.7 to 29.5 ft.) 13 to 79 F3SJ-A££££P25-TS2 Hand 25 mm 20 mm 0.2 to 7 m (0.7 to 23.0 ft.) 87 to 125 F3SJ-A££££P301 Hand/arm 30 mm 25 mm 0.2 to 9 m (0.7 to 29.5 ft.) 10 to 65 F3SJ-A££££P301 Hand/arm 30 mm 25 mm 0.2 to 7 m (0.7 to 23.0 ft.) 70 to 100 F3SJ-A££££P551 Leg/body 55 mm 50 mm 0.2 to 9 m (0.7 to 29.5 ft.) 6 to 33 F3SJ-A££££P551 Leg/body 55 mm 50 mm 0. 2 to 7 m (0.7 to 23.0 ft.) 36 to 50 Notes: Connection cables are not included with the products and must be purchased separately as needed. Protective Height 245 to 1784 mm (9.6 to 70.2 in.) 245 to 1505 mm (9.6 to 59.3 in.) 1655 to 2495 mm (65.2 to 98.2 in.) 245 to 1505 mm (9.6 to 59.3 in.) 1655 to 2495 mm (65.2 to 98.2 in.) 260 to 1580 mm (10.2 to 62.2 in.) 1740 to 2500 mm (68.5 to 98.4 in.) 260 to 1580 mm (10.2 to 62.2 in.) 1740 to 2500 mm (68.5 to 98.4 in.) 245 to 1620 mm (9.6 to 63.8 in.) 1745 to 2495 mm (68.7 to 98.2 in.) 270 to 1620 mm (10.6 to 63.8 in.) 1770 to 2470 mm (69.7 to 97.2 in.) D Specific Model Numbers Model No. of Beams Protective Height (mm) F3SJ-A14 Series F3SJ-A0245P14 26 245 F3SJ-A0263P14 28 263 F3SJ-A0299P14 32 299 F3SJ-A0317P14 34 317 F3SJ-A0389P14 42 389 F3SJ-A0425P14 46 425 F3SJ-A0461P14 50 461 F3SJ-A0533P14 58 533 F3SJ-A0551P14 60 551 F3SJ-A0605P14 66 605 F3SJ-A0623P14 68 623 F3SJ-A0695P14 76 695 F3SJ-A0731P14 80 731 F3SJ-A0767P14 84 767 F3SJ-A0803P14 88 803 F3SJ-A0875P14 96 875 F3SJ-A0911P14 100 911 F3SJ-A0983P14 108 983 F3SJ-A1055P14 116 1055 F3SJ-A1127P14 124 1127 F3SJ-A1199P14 132 1199 F3SJ-A1271P14 140 1271 F3SJ-A1487P14 164 1487 F3SJ-A1631P14 180 1631 F3SJ-A1784P14 197 1784 F3SJ-A20, F3SJ-A20-TS* Series F3SJ-A0245P20 16 245 F3SJ-A0275P20 18 275 F3SJ-A0305P20 20 305 F3SJ-A0395P20 26 395 F3SJ-A0455P20 30 455 F3SJ-A0545P20 36 545 F3SJ-A0575P20 38 575 F3SJ-A0605P20 40 605 Model No. of Beams Protective Height (mm) F3SJ-A0635P20 42 635 F3SJ-A0665P20 44 665 F3SJ-A0695P20 46 695 F3SJ-A0755P20 50 755 F3SJ-A0785P20 52 785 F3SJ-A0815P20 54 815 F3SJ-A0875P20 58 875 F3SJ-A0905P20 60 905 F3SJ-A0935P20 62 935 F3SJ-A0965P20 64 965 F3SJ-A1025P20 68 1025 F3SJ-A1115P20 74 1115 F3SJ-A1205P20 80 1205 F3SJ-A1265P20 84 1265 F3SJ-A1445P20 96 1445 F3SJ-A1505P20 100 1505 F3SJ-A1655P20 110 1655 F3SJ-A1805P20 120 1805 F3SJ-A1955P20 130 1955 F3SJ-A2105P20 140 2105 F3SJ-A2255P20 150 2255 F3SJ-A2405P20 160 2405 F3SJ-A2495P20 166 2495 F3SJ-A25, F3SJ-A25-TS* Series F3SJ-A0260P25 13 260 F3SJ-A0300P25 15 300 F3SJ-A0460P25 23 460 F3SJ-A0540P25 27 540 F3SJ-A0620P25 31 620 F3SJ-A0700P25 35 700 F3SJ-A0780P25 39 780 F3SJ-A0860P25 43 860 F3SJ-A0940P25 47 940 F3SJ-A1020P25 51 1020 F3SJ-A1100P25 55 1100 Model F3SJ-A1180P25 F3SJ-A1260P25 F3SJ-A1420P25 F3SJ-A1500P25 F3SJ-A1580P25 F3SJ-A1740P25 F3SJ-A1900P25 F3SJ-A2060P25 F3SJ-A2220P25 F3SJ-A2380P25 F3SJ-A2420P25 F3SJ-A2500P25 F3SJ-A30 Series F3SJ-A0245P30 F3SJ-A0295P30 F3SJ-A0320P30 F3SJ-A0395P30 F3SJ-A0470P30 F3SJ-A0520P30 F3SJ-A0545P30 F3SJ-A0570P30 F3SJ-A0620P30 F3SJ-A0695P30 F3SJ-A0720P30 F3SJ-A0770P30 F3SJ-A0795P30 F3SJ-A0820P30 F3SJ-A0870P30 F3SJ-A0920P30 F3SJ-A0945P30 F3SJ-A0995P30 F3SJ-A1020P30 F3SJ-A1045P30 F3SJ-A1095P30 F3SJ-A1120P30 No. of Beams Protective Height (mm) 59 63 71 75 79 87 95 103 111 119 121 125 1180 1260 1420 1500 1580 1740 1900 2060 2220 2380 2420 2500 10 12 13 16 19 21 22 23 25 28 29 31 32 33 35 37 38 40 41 42 44 45 245 295 320 395 470 520 545 570 620 695 720 770 795 820 870 920 945 995 1020 1045 1095 1120 Model No. of Beams Protective Height (mm) F3SJ-A1195P30 48 1195 F3SJ-A1220P30 49 1220 F3SJ-A1270P30 51 1270 F3SJ-A1395P30 56 1395 F3SJ-A1495P30 60 1495 F3SJ-A1620P30 65 1620 F3SJ-A1745P30 70 1745 F3SJ-A1820P30 73 1820 F3SJ-A1870P30 75 1870 F3SJ-A1995P30 80 1995 F3SJ-A2245P30 90 2245 F3SJ-A2370P30 95 2370 F3SJ-A2495P30 100 2495 F3SJ-A55 Series F3SJ-A0270P55 6 270 F3SJ-A0320P55 7 320 F3SJ-A0370P55 8 370 F3SJ-A0420P55 9 420 F3SJ-A0470P55 10 470 F3SJ-A0570P55 12 570 F3SJ-A0620P55 13 620 F3SJ-A0720P55 15 720 F3SJ-A0770P55 16 770 F3SJ-A0870P55 18 870 F3SJ-A0920P55 19 920 F3SJ-A0970P55 20 970 F3SJ-A1020P55 21 1020 F3SJ-A1120P55 23 1120 F3SJ-A1170P55 24 1170 F3SJ-A1220P55 25 1220 F3SJ-A1270P55 26 1270 F3SJ-A1320P55 27 1320 F3SJ-A1420P55 29 1420 F3SJ-A1570P55 32 1570 (Continued on next page) Notes: Connection cables are not included with the products and must be purchased separately as needed. * The suffix “-TS” is attached to the model number of models with fixed auto reset. 1 Models with S-mark certification have an “-S” at the end of the model number. S-mark certification is for equipment sold in South Korea. Example: F3SJ-A0245P14-S. 2 Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM “SD Manager” Support Software for F3SJ-A. = Highlighted Rapid Delivery products are available for shipment today or within THREE days. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com D41 F3SJ-A Safety Light Curtains Ordering (continued) Model F3SJ-A1620P55 F3SJ-A1770P55 F3SJ-A1920P55 F3SJ-A2070P55 F3SJ-A2220P55 F3SJ-A2370P55 F3SJ-A2470P55 D No. of Beams Protective Height (mm) 33 36 39 42 45 48 50 1620 1770 1920 2070 2220 2370 2470 information on Resource ✎ For Modules, see page D59. information on safety light ✎ For curtain accessories, see page D74. Accessories Model Description Single-End Connector Cable (2 cables per set, for emitter and receiver) For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller F39-JC3A M12 connector (8-pin), 3 m (9.8 ft.) F39-JC7A M12 connector (8-pin), 7 m (23.0 ft.) F39-JC10A M12 connector (8-pin), 10 m (32.8 ft.) F39-JC15A M12 connector (8-pin), 15 m (49.2 ft.) F39-JC20A M12 connector (8-pin), 20 m (65.6 ft.) Double-End Connector Cable (2 cables per set, for emitter and receiver) For connection with F3SPB1P control unit, and for extension when series-connected. Note: To extend the cable length under series connection, use F39-JJR3W and F39-JC£B in combination. F39-JCR5B M12 connector (8-pin), 0.5 m (1.6 ft.) F39-JC1B M12 connector (8-pin), 1 m (3.3 ft.) F39-JC3B M12 connector (8-pin), 3 m (9.8 ft.) F39-JC5B M12 connector (8-pin), 5 m (16.4 ft.) F39-JC7B M12 connector (8-pin), 7 m (23.0 ft.) F39-JC10B M12 connector (8-pin), 10 m (32.8 ft.) F39-JC15B M12 connector (8-pin), 15 m (49.2 ft.) F39-JC20B M12 connector (8-pin), 20 m (65.6 ft.) Series Connection Cable (2 cables per set, for emitter and receiver) F39-JJR3W Series connection cable3 or when using water-resistant case4, 0.3 m (1.0 ft.) F39-JC£B Extension cable, 0.5 to 15 m (1.6 to 49.2 ft.) To change series connection length in combination with F39-JJR3W F39-JJR06L Side-by-side series connection cable, 0.06 m (2.4 in.) Dedicated series connection cable with minimum length, used in place of the sensor’s cable with connector F39-JJR15L Side-by-side series connection cable, 0.15 m (5.9 in.) Dedicated series connection cable with minimum length, used in place of the sensor’s cable with connector Sensor Mounting Brackets (spare parts) F39-LJ1 Standard mounting bracket (for top/bottom), included with F3SJ system, 2 for emitter and 2 for receiver (total of 4 per set) Flat side mounting bracket, Use these small-sized brackets when performing side F39-LJ2 mounting with standard mounting brackets so that they do not protrude from the F39-JC7A F39-JC15B F39-JJR3W F39-JJR06L F39-JJR15L F39-LJ1 F39-LJ2 detection surface, 2 for emitter and 2 for receiver (total of 4 per set) Free-location mounting bracket (also used as standard intermediate bracket), Use F39-LJ3 these brackets for mounting any place without using standard bracket, 1 set with 2 pieces Key Cap for Muting F39-CN6 Cap attaches to the main unit to enable muting function, attach to either an emitter or a receiver, orange case Setting Tools 5 F39-GWUM SD Manager Software Accessories: SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated F39-MC21 Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual Setting Console Accessories: F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual F39-JC2M Spare cable for F39-GWUM and F39-MC21 3 Total cable length of series connection is 0.6 m to connect to connector cable of the main sensor unit. For series connection with minimum length, use the F39-JJR06L or F39-JJR15L. 4 When using the F39-EJ££££-L/D water-resistant case in series connection configurations, use the special series connection cables for the water-resistant case. (Continued on next page) D42 = Highlighted Rapid Delivery products are available for shipment today or within THREE days. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com F39-LJ3 F39-CN6 F3SJ-A Safety Light Curtains Ordering (continued) Accessories (continued) Model Setting Tools 5 F39-GWUM Description SD Manager Software Accessories: SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m F39-MC21 Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual Setting Console Accessories: F39-GWUM F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable, F39-JC2M Control Unit F3SP-B1P 0.3 m Dedicated Cable with Plug, Instruction Manual Spare cable for F39-GWUM and F39-MC21 D Relay, 3 N.O. + 1 N.C. output, for connection with F3SJ-A, use an F39- JC£B double-end connector cable Force-Guided Relays G7SA-2A2B 4 contacts, 2 N.O. + 2 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A G7SA-3A1B 4 contacts, 3 N.O. + 1 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A G7S-4A2B-E 6 contacts, 4 N.O. + 2 N.C., Rated switch load: 250 VAC 10 A, 30 VDC 10 A G7S-3A3B-E 6 contacts, 3 N.O. + 3 N.O., Rated switch load: 250 VAC 10 A, 30 VDC 10 A Dedicated External Indicator Set (Can be connected to either an emitter or a receiver) F39-A01PR-PAC Indicator (red), mounting bracket (1 set), and dedicated connection cable F39-A01PG-PAC (0.1 m) Indicator (green), mounting bracket (1 set), and dedicated connection cable F39-A01PY-PAC (0.1 m) Indicator (yellow), mounting bracket (1 set), and dedicated connection F39-MC21 G7SA G7S F3SP-B1P cable (0.1 m) General External Indicator Cable F39-JJ3N Cable to connect top of the main unit and an off-the-shelf external indicator F39-A01-PR-PAC (2-wire), 3 m (9.8 ft.) Spatter Protection Cover F39-HJ££££ For F3SJ-A series sensor, reduces operating range by 10%, includes two F39-JJ3N pieces for emitter and receiver Water-Resistant Case (Set of 1 tube, packing, and dedicated connector cable) When using for both emitter and receiver, order two sets. F39-EJ££££-L Water-resistant case for emitter, includes gray cable for emitter F39-EJ££££-D Water-resistant case for receiver, includes black cable for receiver F39-EJ-R 6 Rear mounting brackets, top/bottom 1 each, total of 2 F39-EJ-S 6 Side mounting brackets, top/bottom 1 each, total of 2 F39-JJR3WE-L Series connection cable for emitter, purchase additionally for series F39-JJR3WE-D F39-HJ££££ connection when using the water-resistant case Series connection cable for receiver, purchase additionally for series connection when using the water-resistant case Branch Connector for F3SX (F39-JC£T to F39-JC£B) F39-CN5 Branch connector for F3SX Wire-Saving Devices F39-CN8 Short-circuit connector F39-TC5P01 Connector terminal box with muting sensor output mode (PNP) F39-TC5P02 Connector terminal box with override mode (PNP) F39-TC5N01 Connector terminal box with muting sensor output mode (NPN) F39-TC5N02 Connector terminal box with override mode (NPN) F3SP-T01 Safety terminal relays for F3SJ-A_-P_ Laser Alignment Tool F39-PTJ Laser alignment tool for the F3SJ F39-EJ-R F39-EJ££££-L/D The setting tools described above can be connected only to F3SJ-A models with built-in software of Ver. 2 or later. Note that the setting tools cannot be used with products shipped prior to December 2005. The setting tools cannot be used for setting parameters on the F3SJ-A£-TS series, but the monitoring function can be used. 6 Be sure to purchase brackets with the case to match the mounting direction (rear or side). F39-EJ-S F39-CN5 F39-TC5 5 F3SP-T01 = Highlighted Rapid Delivery products are available for shipment today or within THREE days. F39-PTJ Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com D43 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: F3SJ-A0245P30 F3SJ-A0320P30 F3SJ-A0420P30 F3SJ-A0305P20 F3SJ-A1115P20 F3SJ-A1505P20 F3SJA0245P20 F3SJ-A0520P30 F3SJ-A1025P20
F3SJ-A0420P30 价格&库存

很抱歉,暂时无法提供与“F3SJ-A0420P30”相匹配的价格&库存,您可以联系我们找货

免费人工找货