Safety Light Curtains
F3SJ-A
F3SJA
Rev. 2.12
Safety Light Curtains
D
• Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.)
30 mm (1.18 in.), or 55 mm (2.17 in.)
• Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent on minimum
object resolution and protected height
• Protected heights: 14 mm protected heights from 245 to 1631
mm (9.6 to 64 in.), 20 mm, 25 mm and 30 mm protected
heights from 245 to 2495 mm (9.6 to 98 in.), 55 mm from 270 to
2470 mm (10.6 to 97 in.)
• Very compact size – 30 x 24 mm (1.18 x 0.94 in.)
• Cascaded designs possible – 4 segments, up to 400 beams
• Partial muting and position detection muting
• Cross-talk prevention
Description
Position Detection Muting Function
Warning Zone Function
Position Detection
Muting Function is
used in applications
where the workpiece
is set in position
each time by an
operator, and a
turntable or positioning robot then moves
the workpiece to the
area where the work
is performed. A limit switch or other means is used to detect when
the robot is in a safe position and muting is then applied.
With the F3SJ-A, part of the detection zone can be used as
warning zone to generate an alarm when someone approaches
the danger zone. If the person then enters the danger zone the
F3SJ-A will send a stop signal to the guarded machine. In addition, the auxiliary output can be used to activate a flashing lamp
to alert the person in the warning zone.
The detection zone for a single F3SJ-A can be divided into two
zones or set a single warning zone for multiple, cascaded F3SJ-A
units.
Dividing the zone between series-connected sensors
Detection zone
Partial Muting Function
Muting temporarily disables the F3SJ-A when an object must
pass through the detection zone, such as when supplying a
workpiece to your equipment.
The F3SJ-A beams
Partial muting
continue to guard all
increases the level of
areas except for where
safety by only muting
the workpiece passes
through.
the beams of the
safety light curtain
where the workpiece
passes through, while
preventing muting in
all other areas.
Warning zone
Only the beams of the safety
light curtain interrupted by
the workpiece are muted.
D36
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
This datasheet has been downloaded from http://www.digchip.com at this page
F3SJ-A
Safety Light Curtains
SD Manager Software
Using the SD Manager software, all
features of the F3SJ-A can be set and
checked. Features include:
• Display of system specifications:
– Model
– Number of beams
– Minimum object resolution
– Response time
• Settings for:
– Fixed blanking
– Floating blanking
– Warning zone configuration
– Muting – Both partial and position
detection
– External indicator function
– Auxiliary outputs
– EDM parameters
– Operating range
• Monitoring of received and ambient
light intensity
• Maintenance information:
– Power on time
– OSSD switching frequency
• Recovery of settings
• Safety distance calculations based on
parameters for connected system
“SD Manager” PC Setting Software
F39-GWUM
“SD Manager”
PC Setting
Software
F3SJ-A
To a USB terminal
Branch
Connector
Connection Cable
All parameters can be set and the system status can be checked
with a personal computer. In addition to making it easy to monitor
the beam alignment, the ambient incident light intensity can be
displayed in bar graph form for an easy check of the system status.
● Beam alignment is easier.
● The ambient incident light
intensity can be checked.
Beam Alignment is Easier
The incident light level can be displayed
in a bar graph for each beam.
Setting Console
When you don’t want to take a computer into
the field with you the F39-MC21 setting console
is a convenient way to set parameters and
check the system status.
The incident light level can be displayed in a bar
graph for each beam.
Applications
With built-in muting and
blanking functions, the F3SJ-A
can be employed in a wide
variety of applications from
robotic work cells to small
machines. The potential
for cascaded design and a
broad selection of minimum
object resolutions adds to this
versatility.
D
The incident light level when the light emission of the
Safety Light Curtain is stopped is displayed in a bar
graph.
Selecting the Best Configuration
Space Efficient and Low Cost
The built-in external device monitoring function
eliminates the need for a safety relay unit.
No Safety Relay Unit
F39-JC®A
G7SA
Contactor
Motor
Reduced Wiring and Easy Maintenance
Cables with connectors on both ends simplify
connections and prevent wiring errors.
Connector Type
F39-JC®B
F3SP-B1P
Dedicated controller
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
Contactor
For the Latest Information
On the Internet: www.sti.com
Motor
D37
F3SJ-A
Safety Light Curtains
Specifications
Performance
Resolution:
Protected Height:
Operating Range:
Effective Aperture Angle:
Response Time:
D
Safety Output Rating:
Auxiliary (Non-Safety) Output Ratings:
Light Source:
Indicators:
Mechanical
Enclosure:
Cable Length:
Transmitter and Receiver Cable
Connections:
Electrical
Power Supply:
Environmental
Protection Rating:
Operating Temperature:
Storage Temperature:
Relative Humidity:
Vibration:
Shock:
Approvals
14 mm, 20 mm, 25 mm, 30 mm, 55 mm
14 mm – 245 to 1631 mm (9.6 to 64.2 in.)
20 mm, 25 mm and 30 mm – 245 to 2495 mm (9.6 to 98.2 in.)
55 mm – 270 to 2470 mm (10.6 to 97.2 in.)
0.2 to 9 m for all protective heights up to 1640 mm (64.6 in.)
0.2 to 7 m for all protective heights longer than 1640 mm (64.6 in.):
±2.5° maximum, transmitter and receiver at operating range greater than 3 m (9.8 ft.)
For 14 mm resolution systems up to 983 mm (38.7 in.) protected height ≤17.5 ms
For 14 mm resolution systems above 983 mm (38.7 in.) protected height ≤25 ms
For 20 mm resolution systems up to 1205 mm (47.4 in.) protected height ≤15 ms
For 20 mm resolution systems above 1205 mm (47.4 in.) protected height ≤22.5ms
For 25 mm resolution systems up to 1600 mm (63.0 in.) protected height ≤15 ms
For 25 mm resolution systems above 1600 mm (63.0 in.) protected height ≤20.0ms
For 30 mm resolution systems, all protected heights ≤17.5 ms
For 55 mm resolution systems, all protected heights ≤13 ms
Two 24 VDC PNP outputs sourcing 300 mA max.
One 24 VDC PNP output sourcing 300 mA max.
Infrared LED, 870 nm
Transmitter: 5 LED Light Level Indicators, 3 LED Error Indicators, Power, Interlock, EDM, Blanking/Test
Receiver: 5 LED Light Level Indicators, 3 LED Error Indicators, Machine Run, Machine Stop
Anodized aluminum housing
Optional cables are available up to 20 m (65.6 ft.) in length
M12, 8-pin
24 VDC ± 20%
IP65
-10 to 55°C (14 to 131°F)
-30 to 70°C (-22 to 158°F)
35 to 85% non-condensing
10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
100 m/s2, 1000 times each in X, Y and Z directions
ESPE Type 4 (IEC 61496-1/ -2)
Category 4 / PL e (EN ISO 13849-1)
SIL3 / SIL3 CL3 (IEC 61508)UL508, UL1998, CAN/CSA-C22.2 No. 14, CAN/CSA-C22.2 No. 0.8
Specifications are subject to change without notice.
F3SP-B1P Control Unit
Power Supply Voltage:
24 VDC ±10%
Power Consumption:
DC1.7 W max (not including sensor’s current consumption)
Operation Time:
100 ms max. (not including the sensor’s response time)
Response Time:
10 ms max. (not including the sensor’s response time)
Relay Output
Number of Contacts:
3 N.O., 1 N.C.
Rated Load:
250 VAC 5 A (cos = 1); 30 VDC 5 A L/R = 0 ms
Rated Current:
5A
Connection Type
Between Sensors:
M12 connector (8-pin)
Others:
Terminal block
Weight:
Approx. 280 g (9.9 oz.)
Specifications are subject to change without notice.
D38
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
F3SJ-A
Safety Light Curtains
Wiring
Wiring for Single F3SJ-A Application
Detection of a welded relay contact is possible without a controller relay unit.
Emitter
• Manual reset mode
• Using external device monitoring
function
Receiver
D
F39-JC@A-L
F39-JC@A-D
KM1
KM2
Shield
0 V (Blue)
KM1
Control output 2 (White)
Control output 1 (Green)
Auxiliary output 1 (Yellow)
External device monitoring input (Red)
Communication
line (−) (Pink)
KM4
+24 V (Brown)
+24 V (Brown)
Interlock selection input (White)
Reset input (Yellow)
Test input (Green)
S2
S1
Auxiliary output 2 (Red)
0 V (Blue)
Shield
Communication
line (+) (Gray)
KM1
KM2
KM2
KM3
+24 VDC
IN
OUT
M
E1
0V
PLC
Light incident
Light interrupted
External test switch (S1)
Reset switch (S2)
Control output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
PLC input (See note.)
PLC output
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
D39
F3SJ-A
Safety Light Curtains
Dimensions
(mm)
2-Top/bottom mounting brackets
5.5
2-Mounting holes
30
20
Mounting Screw Holes
(13.75)
4-M5
20
16.5
1
3.75
6.25
30
24
D
31
22
7
Intermediate mounting
bracket
22
2-M5
5.5
B
D
53
A
B
42
42
C (Protective
height)
2-Mounting holes
Beam
10
E
4-Mounting holes
37
300
6 dia.
13.75
6.5 dia.
2-Mounting holes
43
15 dia.
E
9 dia.
M12 Waterproof connector
How to Calculate Your System Dimensions:
C (protective height) = 4-digit number in the table
A = C + 74
B = C + 46.5
D = C - 20
E = see chart below
26
46
Number of
Protective Height
Intermediate Brackets
245 to 596 mm (9.6 to 23.5 in.)
0
600 to 1130 mm (23.6 to 44.5 in.)
1
1136 to 1658 mm (44.7 to 65.3 in.)
2
1660 to 2180 mm (65.4 to 85.8 in.)
3
2195 to 2500 mm (86.4 to 98.4 in.)
4
*Use E = 530 or less when none of the E values shown above are used.
D40
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
E*
—
E = B/2
E = B/3
E = B/4
E = B/5
For the Latest Information
On the Internet: www.sti.com
F3SJ-A
Safety Light Curtains
Ordering
The minimum components required for an F3SJ-A system are a emitter receiver set and a set of
single or double-ended connector cables. See the table below for an overview of the versions available. The pages which follow provide specific part numbers and accessory descriptions.
Safety Light Curtain F3SJ-A
Designator
Protection
Detection
Beam Gap Operating Range
No. of Beams
F3SJ-A££££P141
Finger
14 mm
9 mm
0.2 to 9 m (0.7 to 29.5 ft.)
26 to 197
F3SJ-A££££P201
Finger/Hand 20 mm
15 mm
0.2 to 9 m (0.7 to 29.5 ft.)
16 to 100
F3SJ-A££££P201
Finger/Hand 20 mm
15 mm
0.2 to 7 m (0.7 to 23.0 ft.)
110 to 166
F3SJ-A££££P20-TS2 Finger/Hand 20 mm
15 mm
0.2 to 9 m (0.7 to 29.5 ft.)
16 to 100
F3SJ-A££££P20-TS2 Finger/Hand 20 mm
15 mm
0.2 to 7 m (0.7 to 23.0 ft.)
110 to 166
F3SJ-A££££P251
Hand
25 mm
20 mm
0.2 to 9 m (0.7 to 29.5 ft.)
13 to 79
F3SJ-A££££P251
Hand
25 mm
20 mm
0.2 to 7 m (0.7 to 23.0 ft.)
87 to 125
F3SJ-A££££P25-TS2 Hand
25 mm
20 mm
0.2 to 9 m (0.7 to 29.5 ft.)
13 to 79
F3SJ-A££££P25-TS2 Hand
25 mm
20 mm
0.2 to 7 m (0.7 to 23.0 ft.)
87 to 125
F3SJ-A££££P301
Hand/arm
30 mm
25 mm
0.2 to 9 m (0.7 to 29.5 ft.)
10 to 65
F3SJ-A££££P301
Hand/arm
30 mm
25 mm
0.2 to 7 m (0.7 to 23.0 ft.)
70 to 100
F3SJ-A££££P551
Leg/body
55 mm
50 mm
0.2 to 9 m (0.7 to 29.5 ft.)
6 to 33
F3SJ-A££££P551
Leg/body
55 mm
50 mm
0. 2 to 7 m (0.7 to 23.0 ft.)
36 to 50
Notes: Connection cables are not included with the products and must be purchased separately as needed.
Protective Height
245 to 1784 mm (9.6 to 70.2 in.)
245 to 1505 mm (9.6 to 59.3 in.)
1655 to 2495 mm (65.2 to 98.2 in.)
245 to 1505 mm (9.6 to 59.3 in.)
1655 to 2495 mm (65.2 to 98.2 in.)
260 to 1580 mm (10.2 to 62.2 in.)
1740 to 2500 mm (68.5 to 98.4 in.)
260 to 1580 mm (10.2 to 62.2 in.)
1740 to 2500 mm (68.5 to 98.4 in.)
245 to 1620 mm (9.6 to 63.8 in.)
1745 to 2495 mm (68.7 to 98.2 in.)
270 to 1620 mm (10.6 to 63.8 in.)
1770 to 2470 mm (69.7 to 97.2 in.)
D
Specific Model Numbers
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A14 Series
F3SJ-A0245P14
26
245
F3SJ-A0263P14
28
263
F3SJ-A0299P14
32
299
F3SJ-A0317P14
34
317
F3SJ-A0389P14
42
389
F3SJ-A0425P14
46
425
F3SJ-A0461P14
50
461
F3SJ-A0533P14
58
533
F3SJ-A0551P14
60
551
F3SJ-A0605P14
66
605
F3SJ-A0623P14
68
623
F3SJ-A0695P14
76
695
F3SJ-A0731P14
80
731
F3SJ-A0767P14
84
767
F3SJ-A0803P14
88
803
F3SJ-A0875P14
96
875
F3SJ-A0911P14
100
911
F3SJ-A0983P14
108
983
F3SJ-A1055P14
116
1055
F3SJ-A1127P14
124
1127
F3SJ-A1199P14
132
1199
F3SJ-A1271P14
140
1271
F3SJ-A1487P14
164
1487
F3SJ-A1631P14
180
1631
F3SJ-A1784P14
197
1784
F3SJ-A20, F3SJ-A20-TS* Series
F3SJ-A0245P20
16
245
F3SJ-A0275P20
18
275
F3SJ-A0305P20
20
305
F3SJ-A0395P20
26
395
F3SJ-A0455P20
30
455
F3SJ-A0545P20
36
545
F3SJ-A0575P20
38
575
F3SJ-A0605P20
40
605
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A0635P20
42
635
F3SJ-A0665P20
44
665
F3SJ-A0695P20
46
695
F3SJ-A0755P20
50
755
F3SJ-A0785P20
52
785
F3SJ-A0815P20
54
815
F3SJ-A0875P20
58
875
F3SJ-A0905P20
60
905
F3SJ-A0935P20
62
935
F3SJ-A0965P20
64
965
F3SJ-A1025P20
68
1025
F3SJ-A1115P20
74
1115
F3SJ-A1205P20
80
1205
F3SJ-A1265P20
84
1265
F3SJ-A1445P20
96
1445
F3SJ-A1505P20
100
1505
F3SJ-A1655P20
110
1655
F3SJ-A1805P20
120
1805
F3SJ-A1955P20
130
1955
F3SJ-A2105P20
140
2105
F3SJ-A2255P20
150
2255
F3SJ-A2405P20
160
2405
F3SJ-A2495P20
166
2495
F3SJ-A25, F3SJ-A25-TS* Series
F3SJ-A0260P25
13
260
F3SJ-A0300P25
15
300
F3SJ-A0460P25
23
460
F3SJ-A0540P25
27
540
F3SJ-A0620P25
31
620
F3SJ-A0700P25
35
700
F3SJ-A0780P25
39
780
F3SJ-A0860P25
43
860
F3SJ-A0940P25
47
940
F3SJ-A1020P25
51
1020
F3SJ-A1100P25
55
1100
Model
F3SJ-A1180P25
F3SJ-A1260P25
F3SJ-A1420P25
F3SJ-A1500P25
F3SJ-A1580P25
F3SJ-A1740P25
F3SJ-A1900P25
F3SJ-A2060P25
F3SJ-A2220P25
F3SJ-A2380P25
F3SJ-A2420P25
F3SJ-A2500P25
F3SJ-A30 Series
F3SJ-A0245P30
F3SJ-A0295P30
F3SJ-A0320P30
F3SJ-A0395P30
F3SJ-A0470P30
F3SJ-A0520P30
F3SJ-A0545P30
F3SJ-A0570P30
F3SJ-A0620P30
F3SJ-A0695P30
F3SJ-A0720P30
F3SJ-A0770P30
F3SJ-A0795P30
F3SJ-A0820P30
F3SJ-A0870P30
F3SJ-A0920P30
F3SJ-A0945P30
F3SJ-A0995P30
F3SJ-A1020P30
F3SJ-A1045P30
F3SJ-A1095P30
F3SJ-A1120P30
No. of
Beams
Protective
Height
(mm)
59
63
71
75
79
87
95
103
111
119
121
125
1180
1260
1420
1500
1580
1740
1900
2060
2220
2380
2420
2500
10
12
13
16
19
21
22
23
25
28
29
31
32
33
35
37
38
40
41
42
44
45
245
295
320
395
470
520
545
570
620
695
720
770
795
820
870
920
945
995
1020
1045
1095
1120
Model
No. of
Beams
Protective
Height
(mm)
F3SJ-A1195P30
48
1195
F3SJ-A1220P30
49
1220
F3SJ-A1270P30
51
1270
F3SJ-A1395P30
56
1395
F3SJ-A1495P30
60
1495
F3SJ-A1620P30
65
1620
F3SJ-A1745P30
70
1745
F3SJ-A1820P30
73
1820
F3SJ-A1870P30
75
1870
F3SJ-A1995P30
80
1995
F3SJ-A2245P30
90
2245
F3SJ-A2370P30
95
2370
F3SJ-A2495P30
100
2495
F3SJ-A55 Series
F3SJ-A0270P55
6
270
F3SJ-A0320P55
7
320
F3SJ-A0370P55
8
370
F3SJ-A0420P55
9
420
F3SJ-A0470P55
10
470
F3SJ-A0570P55
12
570
F3SJ-A0620P55
13
620
F3SJ-A0720P55
15
720
F3SJ-A0770P55
16
770
F3SJ-A0870P55
18
870
F3SJ-A0920P55
19
920
F3SJ-A0970P55
20
970
F3SJ-A1020P55
21
1020
F3SJ-A1120P55
23
1120
F3SJ-A1170P55
24
1170
F3SJ-A1220P55
25
1220
F3SJ-A1270P55
26
1270
F3SJ-A1320P55
27
1320
F3SJ-A1420P55
29
1420
F3SJ-A1570P55
32
1570
(Continued on next page)
Notes: Connection cables are not included with the products and must be purchased separately as needed.
* The suffix “-TS” is attached to the model number of models with fixed auto reset.
1
Models with S-mark certification have an “-S” at the end of the model number. S-mark certification is for equipment sold in South Korea. Example: F3SJ-A0245P14-S.
2
Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM “SD Manager” Support Software for F3SJ-A.
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
D41
F3SJ-A
Safety Light Curtains
Ordering (continued)
Model
F3SJ-A1620P55
F3SJ-A1770P55
F3SJ-A1920P55
F3SJ-A2070P55
F3SJ-A2220P55
F3SJ-A2370P55
F3SJ-A2470P55
D
No. of
Beams
Protective
Height
(mm)
33
36
39
42
45
48
50
1620
1770
1920
2070
2220
2370
2470
information on Resource
✎ For
Modules, see page D59.
information on safety light
✎ For
curtain accessories, see page D74.
Accessories
Model
Description
Single-End Connector Cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller
F39-JC3A
M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC7A
M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10A
M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15A
M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20A
M12 connector (8-pin), 20 m (65.6 ft.)
Double-End Connector Cable (2 cables per set, for emitter and receiver) For connection with F3SPB1P control unit, and for extension when series-connected. Note: To extend the cable length under
series connection, use F39-JJR3W and F39-JC£B in combination.
F39-JCR5B
M12 connector (8-pin), 0.5 m (1.6 ft.)
F39-JC1B
M12 connector (8-pin), 1 m (3.3 ft.)
F39-JC3B
M12 connector (8-pin), 3 m (9.8 ft.)
F39-JC5B
M12 connector (8-pin), 5 m (16.4 ft.)
F39-JC7B
M12 connector (8-pin), 7 m (23.0 ft.)
F39-JC10B
M12 connector (8-pin), 10 m (32.8 ft.)
F39-JC15B
M12 connector (8-pin), 15 m (49.2 ft.)
F39-JC20B
M12 connector (8-pin), 20 m (65.6 ft.)
Series Connection Cable (2 cables per set, for emitter and receiver)
F39-JJR3W
Series connection cable3 or when using water-resistant case4, 0.3 m (1.0 ft.)
F39-JC£B
Extension cable, 0.5 to 15 m (1.6 to 49.2 ft.)
To change series connection length in combination with F39-JJR3W
F39-JJR06L
Side-by-side series connection cable, 0.06 m (2.4 in.) Dedicated series connection
cable with minimum length, used in place of the sensor’s cable with connector
F39-JJR15L
Side-by-side series connection cable, 0.15 m (5.9 in.) Dedicated series connection
cable with minimum length, used in place of the sensor’s cable with connector
Sensor Mounting Brackets (spare parts)
F39-LJ1
Standard mounting bracket (for top/bottom), included with F3SJ system,
2 for emitter and 2 for receiver (total of 4 per set)
Flat side mounting bracket, Use these small-sized brackets when performing side
F39-LJ2
mounting with standard mounting brackets so that they do not protrude from the
F39-JC7A
F39-JC15B
F39-JJR3W
F39-JJR06L
F39-JJR15L
F39-LJ1
F39-LJ2
detection surface, 2 for emitter and 2 for receiver (total of 4 per set)
Free-location mounting bracket (also used as standard intermediate bracket), Use
F39-LJ3
these brackets for mounting any place without using standard bracket, 1 set with 2
pieces
Key Cap for Muting
F39-CN6
Cap attaches to the main unit to enable muting function, attach to either an emitter or
a receiver, orange case
Setting Tools 5
F39-GWUM
SD Manager Software Accessories:
SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated
F39-MC21
Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual
Setting Console Accessories:
F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable,
0.3 m Dedicated Cable with Plug, Instruction Manual
F39-JC2M
Spare cable for F39-GWUM and F39-MC21
3
Total cable length of series connection is 0.6 m to connect to connector cable of the main sensor unit.
For series connection with minimum length, use the F39-JJR06L or F39-JJR15L.
4
When using the F39-EJ££££-L/D water-resistant case in series connection configurations, use the
special series connection cables for the water-resistant case.
(Continued on next page)
D42
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
F39-LJ3
F39-CN6
F3SJ-A
Safety Light Curtains
Ordering (continued)
Accessories (continued)
Model
Setting Tools 5
F39-GWUM
Description
SD Manager Software Accessories:
SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m
F39-MC21
Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual
Setting Console Accessories:
F39-GWUM
F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable,
F39-JC2M
Control Unit
F3SP-B1P
0.3 m Dedicated Cable with Plug, Instruction Manual
Spare cable for F39-GWUM and F39-MC21
D
Relay, 3 N.O. + 1 N.C. output, for connection with F3SJ-A, use an F39-
JC£B double-end connector cable
Force-Guided Relays
G7SA-2A2B
4 contacts, 2 N.O. + 2 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7SA-3A1B
4 contacts, 3 N.O. + 1 N.C., Rated switch load: 250 VAC 6 A, 30 VDC 6 A
G7S-4A2B-E
6 contacts, 4 N.O. + 2 N.C., Rated switch load: 250 VAC 10 A, 30 VDC 10 A
G7S-3A3B-E
6 contacts, 3 N.O. + 3 N.O., Rated switch load: 250 VAC 10 A, 30 VDC 10 A
Dedicated External Indicator Set (Can be connected to either an emitter or a receiver)
F39-A01PR-PAC
Indicator (red), mounting bracket (1 set), and dedicated connection cable
F39-A01PG-PAC
(0.1 m)
Indicator (green), mounting bracket (1 set), and dedicated connection cable
F39-A01PY-PAC
(0.1 m)
Indicator (yellow), mounting bracket (1 set), and dedicated connection
F39-MC21
G7SA
G7S
F3SP-B1P
cable (0.1 m)
General External Indicator Cable
F39-JJ3N
Cable to connect top of the main unit and an off-the-shelf external indicator
F39-A01-PR-PAC
(2-wire), 3 m (9.8 ft.)
Spatter Protection Cover
F39-HJ££££
For F3SJ-A series sensor, reduces operating range by 10%, includes two
F39-JJ3N
pieces for emitter and receiver
Water-Resistant Case (Set of 1 tube, packing, and dedicated connector cable)
When using for both emitter and receiver, order two sets.
F39-EJ££££-L
Water-resistant case for emitter, includes gray cable for emitter
F39-EJ££££-D
Water-resistant case for receiver, includes black cable for receiver
F39-EJ-R 6
Rear mounting brackets, top/bottom 1 each, total of 2
F39-EJ-S 6
Side mounting brackets, top/bottom 1 each, total of 2
F39-JJR3WE-L
Series connection cable for emitter, purchase additionally for series
F39-JJR3WE-D
F39-HJ££££
connection when using the water-resistant case
Series connection cable for receiver, purchase additionally for series
connection when using the water-resistant case
Branch Connector for F3SX (F39-JC£T to F39-JC£B)
F39-CN5
Branch connector for F3SX
Wire-Saving Devices
F39-CN8
Short-circuit connector
F39-TC5P01
Connector terminal box with muting sensor output mode (PNP)
F39-TC5P02
Connector terminal box with override mode (PNP)
F39-TC5N01
Connector terminal box with muting sensor output mode (NPN)
F39-TC5N02
Connector terminal box with override mode (NPN)
F3SP-T01
Safety terminal relays for F3SJ-A_-P_
Laser Alignment Tool
F39-PTJ
Laser alignment tool for the F3SJ
F39-EJ-R
F39-EJ££££-L/D
The setting tools described above can be connected only to F3SJ-A models with built-in software of
Ver. 2 or later. Note that the setting tools cannot be used with products shipped prior to December 2005.
The setting tools cannot be used for setting parameters on the F3SJ-A£-TS series, but the monitoring
function can be used.
6
Be sure to purchase brackets with the case to match the mounting direction (rear or side).
F39-EJ-S
F39-CN5
F39-TC5
5
F3SP-T01
= Highlighted Rapid Delivery products are available for shipment today or within THREE days.
F39-PTJ
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
D43