0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FQ-XPM

FQ-XPM

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    PANEL MOUNT ADAPTER

  • 数据手册
  • 价格&库存
FQ-XPM 数据手册
CODE READER FQ-CR SERIES Exceptional Reading Performance with Easy Operation Multi Code Reader FQ-CR1 Series 2D Code Reader for Direct Part Marking codes FQ-CR2 Series » Read from everything from paper and labels to metal, PCBs, and glass for a wide range of applications. 2 Solve a variety off different applications with one product series Read Codes Printed on Paper or Labels Paper or Cardboard Multi Code Reader FQ-CR1 Series Medical Packs ITF (Interleaved 2 of 5) PET Bottles QR Code Codebar (NW-7) Data Matrix GS1-DataBar Medication Boxes JAN/EAN/UPC FQ-CR1 Reads 14 Different Codes Many different codes are used for different applications. And for some products, different codes are printed together. The FQ-CR1 can read many different codes without requiring any changes to its settings. Barcodes: Reads 9 JAN/EAN/UPC Code39 Codabar ( NW-7 ) ITF (Interleaved 2 of 5) Code93 Code128 / GS1-128 different codes. GS1-DataBar GS1-128 Composite Code Pharmacode 2D codes: Data Matrix QR Code Micro QR Code PDF417 Micro PDF417 Reads 5 different codes. • QR code is the registered trademark of DENSO WAVE. 3 There are many instances when different barcode or 2D code systems are used together in the same manufacturing process. Code printing quality can also vary due to imperfect printing or low contrast. The FQ-CR Series handles these and many other conditions. The FQ-CR Series can be easily introduced without using different code readers and operating procedures for each of the different processes. 2D Code Reader for Direct Part Marking (DPM) codes Reads Direct Part Marking (DPM) Codes FQ-CR2 Series DPM codes on Resin Data Matrix DPM codes on small parts DPM codes on film or glass DPM codes on metal Data Matrix Data Matrix Data Matrix FQ-CR2 Easily reads difficult codes Just read the code and register it, and then let the following functions automatically tune the settings. Depending on the conditions of the code, the automatic retry and code error correction functions let, essentially anyone, easily adjust the settings. Filter function Retry function Code Error Correction Three stages of filtering are automatically selected for the read image from Smooth, Dilate, Erosion, and Median filtering. You can retry the settings until reading is successful while automatically changing the exposure time and other reading parameters. Code omissions and errors are automatically corrected when the code is read. Before Dilation After Dilation Before Retry After Retry Before Processing After Processing 4 FQ-CR2 OMRON’s Unique Algorithm Provides Superior Reading Ability for Direct Part Marking codes Removal of Printing Irregularities or Noise Filter function You can apply up to three of the four unique filters developed by OMRON in the desired order to remove printing irregularities and noise, in order to achieve a stable reading. Types of Filtering Smooth Dilate Combining Filtering Smooths the image. Erosion For white codes, reduces the cell size. Effective for reading separated dot codes. For white codes, increases the cell size. Effective for reading codes with cell spreading. Median Removes noise. Erosion and dilation can be combined to connect dots without changing the dot thickness. Dilate Erosion 5 Reading Automatic Parameter Adjustment Until Reading is Successful Retry function Code Readers must be able to read codes even for poor printing conditions. You can automatically retry reading while changing the exposure time and other reading conditions, even for changing workpieces or environments, to enable a stable reading. The following retry functions are provided. 1 Retrying the Specified Number of Times with the Same Conditions 2 Retrying While External Trigger Is Input 3 Retrying While Changing the Shutter Speed 4 NG NG OK Reading is performed the specified number of times for the same scene. During level trigger input Reading is performed until successful, as long as an external level trigger is input. NG Reading is performed for the same scene while changing the exposure time in stages. OK NG NG NG OK 1ms 1.3ms 0.7ms 1.6ms Retrying While Changing the Reading Conditions When reading DPM codes, inconsistencies in printing conditions can result in NGs if reading is performed with only one set of reading settings. NG NG NG OK Scene 1 Scene 2 Scene 3 Register 32 sets of reading conditions. Rapidly switch to the optimum reading conditions. The FQ-CR allows you to register up to 32 sets of reading conditions as scenes and retry reading while changing the scenes in order. The system automatically determines the scenes with the highest usage rates and changes the order to start Scene 2 Scene 4 Scene 6 Scene 8 Scene 32 with them to flexibly handle changes in reading conditions. Of course you can specify a fixed order if required. Scene 1 Easy Confirmation of Code Quality Code Error Correction Position Display Red circles are displayed on cells for which the code was corrected on the display. This clearly shows where the code quality was poor. Scene 3 Scene 5 Scene 7 Scene 31 6 FQ-CR1 FQ-CR2 Stable Reading Functions Packed into a Compact Body Polarization filter Cuts specular reflections. High power LEDs Four times the brightness of previous models. Lens and Camera simple fine tuning of camera focus. Actual Size Decoder Built-in HDR function. Robust housing: IP67 Ethernet Output Output read codes on Ethernet. 7 Detection and Connection Reads Codes Even with Low Contrast High-power LEDs The wider the field of view, the more difficult it is to maintain consistent lighting within the field, causing errors in reading. The built-in LEDs of the FQ-CR Series use a unique OMRON DR optical system for effective light usage to maintain consistent lighting within the field of vision at a brightness that is four times that of previous models. Previous Lighting High-power Lighting Halation Stable Detection for Metal Surfaces Subject to Gloss and Inconsistent Lighting Without Polarizing Filter With Polarizing Filter Cuts Light Interference HDR Function The HDR (high dynamic range) function minimizes the influence of changes in lighting conditions and light reflection. This enables stable inspections even for materials that are difficult to light evenly, such as metal parts or glossy films, or in locations subject to external light interference. Cuts Specular Reflections Polarizing Filter A polarizing filter is included to cut specular reflection from glossy surfaces. This enables stable code reading even for metallic or other glossy surfaces. Communications with Host Devices Ethernet Connection The compact body also provides an Ethernet connector so that you can transfer read data and images via Ethernet. Smoothly transfer data to PLCs, computers, or other host devices. Ethernet 8 FQ-CR1 FQ-CR2 Essentially, Simple Enough for Anyone to Set Up Setup is as easy as displaying codes on the monitor and registering settings with a simple procedure. Then, the FQ-CR will automatically tune the settings to achieve the optimum conditions. You can automatically tune all of these reading conditions just by making the basic settings. Optimum Tuning in Three Steps Read a code. Select the type of code. Two Set-up Tools Use the convenient Touch Finder for on-site settings and control panel installations, or use a set-up tool on a computer. Touch Finder TouchFinder for PC (Free) After purchasing the Code Reader, you can ca download the TouchFinder for PC free from the member’s website. 9 Set-up and Adjustment Exposure Time Gain Press the TEACH Button. Dynamic Range Filtering Check to see if the conditions are correct as a reference. END Menu Displays in Nine Languages Operation Navigation The nine language support for menus means that you can easily introduce systems into factory sites in other countries. In addition, you can easily change the language on a menu. Navigation menus for operating procedures from image adjustment through to testing and starting operation are provided so that even beginners can operate the Code Reader. English German Japanese French Traditional Chinese Italian Simplified Chinese Spanish Korean Setup flow 10 FQ-CR1 FQ-CR2 Flexible System Configuration Connect Up To Eight Code Readers The flexibly arrangeable platform can be used for simple configurations with one Code Reader for complex configurations with multiple Code Readers reading from different directions. Up to eight Code Readers can be controlled from the Touch Finder set-up console. Code Quality Management The FQ-CR2 contains state-of-the-art algorithms that enable the reading of codes even with poor reading quality. However, even if the code quality continues to deteriorate for some reason, auto-correction and retrying are used to enable reading, making it impossible to tell where quality was lost simply from the OK/NG reading information. Here, you can use the cell recognition rate information. The cell recognition rate changes with code printing quality, position inconsistency, installation conditions, and noise. You can log the cell recognition rate and image together to manage quality trends. The logging of recent results is useful for testing when commissioning a line. Run through some sample products and log the cell recognition rate. You can then display the results in a time-based graph to see how much leeway there is in reading performance. * For the FQ-CR1, the number of detected characters is logged instead of the cell recognition rate. gging File Logging SD Card Cell recognition rate Up to 10 million measurement values or more (for a 4-GB SD card) Up to 10,000 images or more (for a 4-GB SD card) Loggingg of Recent Results Displays the most recent 1,000 cell recognition rate in graph form. 11 Commissioning and Operation Match your field of view  No matter whether you handle large or small workpieces, the range of Omron FQ-CR Code Readers offers a perfect match. Select the FQ-CR model with the appropriate range and adjust the field of view to your application. Focusing is quick and easy too, enabling you to use the sensor for a variety of applications. Field of vision 13 7.5 4.7 38 Narrow view 0 Field of vision 8.2 57 53 33 13 8.2 56 Standard 0 215 240 Field of vision Touch Finder 153 53 Wide View (long-distance) 33 220 0 970 300 Field of vision 191 29 Wide View (short-distance) TouchFinder for PC Automatic Notification of NGs If you leave the Touch Finder installed on-site, the recent NG sensor display is very useful. Even if you are monitoring more than one Code Reader with the Touch Finder, the display automatically changes to the Code Reader where an NG occurred so that you can quickly confirm conditions. ! 18 0 32 380 12 System Configuration Connections for One Code Reader Control by parallel input/output Control by Ethernet FQ-CR Code Reader Touch Finder FQ-CR Ethernet Cables I/O Cables FQ-CR Code Reader Sensor trigger Switching Hub Touch Finder Sensor trigger PLC Power Supply 24 VDC FQ-CR Ethernet Cables Power Supply 24 VDC I/O Cables Standard Ethernet Cables (RJ-45 of the FCC regulations) PLC Standard Ethernet Cables (RJ-45 of the FCC regulations) Connections for Multiple Code Reader Control by parallel input/output Control by Ethernet Up to 32 Code Reader can be connected. Up to 32 Code Reader can be connected. FQ-CR Ethernet Cables Touch Finder Switching Hub Standard Ethernet Cables (RJ-45 of the FCC regulations) Touch Finder Connect the trigger sensor, power supply to each Code Reader. FQ-CR Ethernet Cables Switching Hub Standard Ethernet Cables (RJ-45 of the FCC regulations) Standard Ethernet Cables (RJ-45 of the FCC regulations) Connect the trigger sensor, power supply to each Code Reader. PLC Note: If you register as a member after purchasing a Code Reader, you can download the free set-up software TouchFinder for PC that runs on a PC and can be used in place of the Touch Finder. Refer to the member registration sheet for details. Ordering Information Code Reader Narrow View Standard (Unit: mm) Wide View (Short-distance) (Long-distance) 300 240 Field of vision Field of vision 7.5 8.2 56 0 2D Code Reader 33 13 8.2 4.7 57 38 to 0 53 Field of vision 13 Multi Code Reader 53 2D Code Reader Multi Code Reader 970 18 32 to 220 0 191 29 33 215 to 153 Field of vision 0 2D Code Reader Multi Code Reader 2D Code Reader 380 to Multi Code Reader NPN FQ-CR20010F-M FQ-CR10010F-M NPN FQ-CR20050F-M FQ-CR10050F-M NPN FQ-CR20100F-M FQ-CR10100F-M NPN FQ-CR20100N-M FQ-CR10100N-M PNP FQ-CR25010F-M FQ-CR15010F-M PNP FQ-CR25050F-M FQ-CR15050F-M PNP FQ-CR25100F-M FQ-CR15100F-M PNP FQ-CR25100N-M FQ-CR15100N-M Note: Tolerance (field of vision): ±10% max. Touch Finder Accessories Type Model DC power supply FQ2-D30 AC/DC/battery FQ2-D31 (See note.) Application Note: AC Adapter and Battery are sold separately. For Code Reader Cables (Robot cable) Type Cable length FQ Ethernet Cables (connect Code Reader to Touch Finder, Code Reader to PC) I/O Cables Model 2m FQ-WN002 10 m FQ-WN010 20 m FQ-WN020 2m FQ-WD002 10 m FQ-WD010 20 m FQ-WD020 Industrial Switching Hubs (Recommended) Appearance Number of ports 5 Current consumption 0.07 A Model For Touch Finder Appearance Name Model Mounting Bracket (enclosed with Code Reader) FQ-XL Mounting Bracket for highprecision sensing *1 (sold separately) FQ-XL2 Polarizing Filter Attachment (enclosed with Code Reader) FQ-XF1 Panel Mounting Adapter FQ-XPM AC Adapter (for models for DC/AC/Battery) FQ-AC1 Battery *2 (for models for DC/AC/Battery) FQ-BAT1 Touch Pen (enclosed with Touch Finder) FQ-XT Strap FQ-XH SD Card (2 GB) HMC-SD291 W4S1-05D *1. A mounting Bracket with improved resistance to vibrations and other external stresses that cause displacement of the optical axis and field of view. *2. The Battery uses a lithium ion secondary battery. Confirm any applicable laws and regulations in the destination country if you export the Battery. 13 Ratings and Performance Code Reader Item Type Model 2D Code Reader Multi Code Reader NPN FQ-CR20@@@@-M FQ-CR10@@@@-M PNP FQ-CR25@@@@-M FQ-CR15@@@@-M Field of vision Refer to the table below. Installation distance FQ-CR2@010F-M/-CR1@010F-M: 0.040 mm FQ-CR2@050F-M/-CR1@050F-M: 0.070 mm FQ-CR2@100F-M/-CR1@100F-M: 0.282 mm FQ-CR2@100N-M/-CR1@100N-M: 0.155 mm Minimum resolution 2D Code (DataMatrix (EC200), QR Code, MicroQR Code, PDF417, MicroPDF417, GS1-DataMatrix) Bar code (JAN/EAN/UPC, Code39, Codabar (NW-7), ITF (Interleaved 2 of 5), Code 93, Code128/GS1-128, GS1 DataBar* (Truncated, Stacked, Omni-directional, Stacked Omni-directional, Limited, Expanded and Expanded Stacked), Pharmacode and GS1-128 Composite Code (CC-A, CC-B, CC-C)) Code 2D Code (DataMatrix (EC200), QR Code) Image filter Filter function (Smooth, Dilate, Erosion,Median), Retry function, Code Error Correction Position Display None Verification function None Supported Number of simultaneous inspections 32 Number of registered scenes 32 Image filter High dynamic range (HDR), polarizing filter (attachment) Image elements 1/3-inch monochrome CMOS Shutter 1/250 to 1/32,258 s Processing resolution 752 × 480 Lighting method Pulse Lighting color White LED class Risk Group 2 (IEC62471) Measurement data In Code Reader:1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.) Images In Code Reader:20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.) Main functions Image input Lighting Data logging Measurement trigger I/O specifications Ratings 1/250 to 1/30,000 s External trigger (single or continuous) Input signals 7 signals • Single measurement input (TRIG) • Control command inputs (IN0 to IN5) Output signals 3 signals • Control output (BUSY) • Overall judgement output (OR) • Error output (ERROR) Note: The three output signals can be allocated for the judgements of individual inspection items. Ethernet specification Numerical outputs and control commands are supported with no-protocol communications. 100BASE-TX/10BASE-T Connection method Special connector cables • Power supply and I/O: 1 cable (FQ-WD@@@) • Touch Finder and computer: 1 cable (FQ-WN@@@) Power supply voltage 21.6 to 26.4 VDC (including ripple) Current consumption 2.4 A max. Ambient temperature range Operating: 0 to 50°C Storage: −25 to 65°C (with no icing or condensation) Environmental Ambient humidity range immunity Ambient atmosphere Operating and storage: 35% to 85% (with no condensation) No corrosive gas Degree of protection IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted.) Code Reader: Mounting Bracket: Polarizing Filter Attachment: Ethernet connector: I/O connector: Materials • Mounting Bracket (FQ-XL) (1) • Polarizing Filter Attachment (FQ-XF1) (1) • Instruction Manual Accessories 2D Code Reader NPN PBT, PC, SUS PBT PBT, PC Oil-resistance vinyl compound Lead-free heat-resistant PVC PNP Multi Code Reader NPN PNP Field of view (See note) (Horizontal × Vertical) • Member registration sheet Installation distance FQ-CR20010F-M FQ-CR25010F-M FQ-CR10010F-M FQ-CR15010F-M 7.5 × 4.7 to 13 × 8.2 mm FQ-CR20050F-M FQ-CR25050F-M FQ-CR10050F-M FQ-CR15050F-M 13 × 8.2 to 53 × 33 mm 56 to 215 mm FQ-CR20100F-M FQ-CR25100F-M FQ-CR10100F-M FQ-CR15100F-M 53 × 33 to 240 × 153 mm Long-distance model: 220 to 970 mm FQ-CR20100N-M FQ-CR25100N-M FQ-CR10100N-M FQ-CR15100N-M 29 × 18 to 300 × 191 mm Note: Tolerance: ±10% max. Weight 38 to 57 mm Short-distance model: 32 to 380 mm 200 g max. 14 Touch Finder Type Item Model with AC/DC/battery power supply FQ2-D30 FQ2-D31 Number of sensors that can be recognized (switched): 32 max. number or sensor that can displayed on monitor: 8 max. Number of connectable Sensor Main functions Model with DC power supply Model Types of measurement displays Last result display, Last NG display, trend monitor, histograms Types of display images Through, frozen, zoom-in, and zoom-out images Data logging Measurement results, measured images Menu language English, German, French, Italian, Spanish, Traditional Chinese, Simplified Chinese, Korean, Japanese LCD Indications Backlight Display device 3.5-inch TFT color LCD Pixels 320 × 240 Display colors 16.7 million Life expectancy *1 50,000 hours at 25ºC Brightness adjustment Provided Screen saver Provided Method Resistance film Operation interface Touch screen External interface Ethernet 100BASE-TX/10BASE-T SD card SDHC-compliant, Class 4 or higher recommended Power supply voltage DC power connection:21.6 to 26.4 VDC (including ripple) Life expectancy *2 1,000,000 touch operations DC power connection: 21.6 to 26.4 VDC (including ripple) AC adapter (manufactured by Sino-American Japan Co., Ltd) connection: 100 to 240 VAC, 50/60 Hz Battery connection: FQ-BAT1 Battery (1cell, 3.7 V) Ratings Continuous operation on Battery *3 Environmental immunity --- 1.5 h Power consumption DC power connection: 0.2 A max. DC power connection: 0.2 A max. Charging battery: 0.4 A max. Ambient temperature range Operating: 0 to 50ºC Storage: −25 to 65ºC (with no icing or condensation) Operating: 0 to 50ºC when mounted to DIN Track or panel Operation on Battery: 0 to 40ºC Storage: −25 to 65ºC (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Ambient atmosphere No corrosive gas Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times Shock resistance (destruction) 150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) Degree of protection IEC 60529 IP20 (when SD card cover, connector cap, or harness is attached) Weight Approx. 270 g (without Battery and hand strap attached) Materials Case: ABS Accessories included with Touch Finder Touch Pen (FQ-XT), Instruction Manual *1. This is a guideline for the time required for the brightness to diminish to half the initial brightness at room temperature and humidity. The life of the backlight is greatly affected by the ambient temperature and humidity and will be shorter at lower or higher temperatures. *2. This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions. *3. This value is only a guideline. No guarantee is implied. The value will be affected by the operating environment and operating conditions. Battery Specifications Item Model FQ-BAT1 Battery type Secondary lithium ion battery Nominal capacity 1,800 mAh Rated voltage 3.7 V Ambient temperature range Operating: 0 to 40ºC Storage: −25 to 65ºC (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Charging method Charged in Touch Finder (FQ-D31). AC adapter (FQ-AC@) is required. Charging time (See note 1.) 2h Battery backup life (See note 2.) 300 charging cycles Weight 50 g max. Note: 1. This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions 2. This is a guideline for the time required for the capacity of the Battery to be reduced to 60% of the initial capacity. No guarantee is implied. The value will be affected by the operating environment and operating conditions. System Requirements for TouchFinder for PC The following Personal Computer system is required to use the software. OS Microsoft Windows XP Home Edition/Professional SP2 or higher (See note 1.) Microsoft Windows 7 Home Premium or higher (See note 1.) CPU Core 2 Duo 1.06 GHz or the equivalent or higher RAM 1GB min. HDD 500 MB min. available space (See note 2.) Monitor 1,024 × 768 dots min. Note: 1. The Japanese and English versions support only 32-bit OS versions. 2. Available space is also required separately for data logging. Dimensions (Unit: mm) Code Reader (Dimensional drawings are provided here only for the products that have undergone design changes as of June 2012.) FQ-CR Mounting with the FQ-XL2 Mounting Bracket Mounting with the FQ-XL Mounting Bracket (57) Optical axis 45 40 30 67 5 (108) 1 OPTICAL AXIS Plate 8 Cushion 18 (See note 1.) 1/4-20UNC Depth: 6 Four-M4 Depth: 6 9 32 Polarizing Filter Attachment (108) 67 59 20±0.1 (65) Mounting Bracket 20±0.1 38.8 46 Four machine screws (double pan-head set screws) t1 Base Mounting Hole Dimensions 38 (See note 2.) 41 38 Two, 4.5 dia. 20±0.1 20±0.1 Mounting Hole Dimensions 8 49 Two, 4.5 dia. Tightening torque: 1.2 N.m * Dimentions with the FQ-XL Mounting Bracket Type Model Note 1. Note 2. Narrow View, Standard FQ-CR1@010F-M/-CR2@010F-M/ -CR1@050F-M/-CR2@050F-M 11 57 Wide View FQ-CR1@100F-M/-CR2@0100F-M/ -CR1@100N-M/-CR2@100N-M 3 49 Touch Finder FQ2-D30/-D31 Panel Mounting Adapter (36.9) (2) 31.6 20 3.5 116 95 44.5 95 (See note.) 27.9 85 85 23.8 14 52.9 35.5 (133.4) 70 116 33 (8.1) 12.1 Panel Cutout Dimensions 13.5 15 111±1 27 111±1 17.3 19.2 10 (See note.) Note: Provided with FQ2-D31 only. Panel 15 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2011-2021 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_14_2 Cat. No. Q186-E1-02 0721 (0811)
FQ-XPM 价格&库存

很抱歉,暂时无法提供与“FQ-XPM”相匹配的价格&库存,您可以联系我们找货

免费人工找货