G2R-1-SNDC12(S)

G2R-1-SNDC12(S)

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    RELAYGENPURPOSESPDT10A12V

  • 详情介绍
  • 数据手册
  • 价格&库存
G2R-1-SNDC12(S) 数据手册
New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Nameplate Overview LED indicator Mechanical indicator Test button DC: Blue AC: Red New Features • Nameplate and mechanical indicator provided as a standard. • Models with two-way-action test button available. • Environment-friendly construction. Two-way-action test button Relay in operation For momentary testing Pull down the test button to the first stop position, then press the yellow button with an insulated tool to operate the contact. For lock testing Pull down the test button to the second stop position. (The contact is now in the locked position.) General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay • Lockable test button models now available. • Built-in mechanical operation indicator. • Provided with nameplate. • AC type is equipped with a coil-disconnection selfdiagnostic function (LED type). • High switching power (1-pole: 10 A). • Environment-friendly (Cd, Pb free). • Wide range of Sockets also available. LR Model Number Structure ■ Model Number Legend G2R 1 2 3 4 5 6 7 5. Terminals S: Plug-in 6. Classification Blank:General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 7. Rated Coil Voltage 1. Relay Function Blank:General-purpose 2. Number of Poles 1: 1 pole 2: 2 poles 3. Contact Form Blank:SPDT 4. Contact Type Blank:Single Ordering Information ■ List of Models Classification Plug-in terminal General-purpose Enclosure rating Unsealed Coil ratings Contact form/Model SPDT AC/DC G2R-1-S DPDT G2R-2-S LED indicator G2R-1-SN G2R-2-SN LED indicator with test button G2R-1-SNI G2R-2-SNI Diode G2R-1-SD G2R-2-SD LED indicator and diode DC G2R-1-SND G2R-2-SND LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. New model Example: G2R-1-S DC12 (S) Rated coil voltage General-purpose Relay G2RS 1 ■ Accessories (Order Separately) Connecting Sockets Applicable Relay model Track/surface-mounting Socket Screwless clamp terminal Back-mounting Socket Screw terminal Terminals Model 1 pole • P2RF-05S (See note.) + G2R-1-S(N)(D)(ND)(NI)(NDI) (P2CM-S (option)) • P2RF-05-E PCB terminals P2R-05P, P2R-057P • P2RF-05 Solder terminals P2R-05A 2 poles • P2RF-08S (See note.) + G2R-2-S(N)(D)(ND)(NI)(NDI) (P2CM-S (option)) • P2RF-08-E PCB terminals P2R-08P, P2R-087P • P2RF-08 Solder terminals P2R-08A Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting. Accessories for Screwless Clamp Terminal Socket (Option) Name Model Clip & Release Lever P2CM-S Nameplate R99-11 Nameplate for MY Socket Bridge P2RM-SR (for AC), P2RM-SB (for DC) Mounting Tracks Applicable Socket Description Mounting track and accessories Mounting track Mounting plate Model 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S Back-connecting Sockets P2R-P* *Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. Specifications ■ Coil Ratings Rated voltage Rated current* 50 Hz AC Coil resistance* 60 Hz Coil inductance (H) (ref. value) Armature OFF 24 V 43.5 mA 37.4 mA 253 Ω 0.81 1.55 110 V 9.5 mA 8.2 mA 5,566 Ω 13.33 26.83 32.46 120 V 8.6 mA 7.5 mA 7,286 Ω 16.13 230 V 4.4 mA 3.8 mA 27,172 Ω 72.68 143.90 240 V 3.7 mA 3.2 mA 30,360 Ω 90.58 182.34 Rated voltage Rated current* Coil resistance* Coil inductance (H) (ref. value) Armature OFF DC Armature ON Armature ON 6V 87.0 mA 69 Ω 0.25 0.48 12 V 43.2 mA 278 Ω 0.98 2.35 24 V 21.6 mA 1,113 Ω 3.60 8.25 48 V 11.4 mA 4,220 Ω 15.2 29.82 Must operate voltage Must release voltage General-purpose Relay G2RS Power consumption (approx.) % of rated voltage 80% max. Must operate voltage 30% min. Must release voltage 110% Max. voltage 0.9 VA at 60 Hz Power consumption (approx.) % of rated voltage 70% max. 15% min. * The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%. 2 Max. voltage 110% 0.53 W ■ Contact Ratings Number of poles 1 pole Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load (cosφ = 1) 2 poles Inductive load (cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 7.5 A at 250 VAC; 5 A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 2 A at 250 VAC; 3 A at 30 VDC Rated carry current 10 A 5A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A Max. switching capacity 2,500 VA, 300 W Minimum permissible load 100 mA at 5 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W 10 mA at 5 VDC Note: P level: λ60 = 0.1 x 10-6/operation ■ Characteristics Item 1 pole 2 poles Contact resistance 100 mΩ max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: Electrical: Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; contacts*; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Vibration resistance Destruction: Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: Malfunction: 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized Service life Mechanical: AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 18,000 operations/hr 1,800 operations/hr (under rated load) Electrical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type) Ambient temperature Operating: –40°C to 70°C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 21 g Note: Values in the above table are the initial values. *4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used. ■ Approved Standards UL 508 (File No. E41643) Model Contact form G2R-1-S SPDT Coil ratings 5 to 110 VDC 5 to 240 VAC G2R-2-S DPDT IEC/VDE (EN61810) Contact ratings Operations Contact form 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 440 VAC (cosφ = 1.0) 10 A, 250 VAC (cosφ = 1.0) 10 A, 30 VDC (0 ms) 100 x 103 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 250 VAC (cosφ =1.0) 5 A, 30 VDC (0 ms) 100 x 103 CSA 22.2 No.0, No.14 (File No. LR31928) Model Contact form G2R-1-S SPDT G2R-2-S DPDT Coil ratings 5 to 110 VDC 5 to 240 VAC Coil ratings Contact ratings Operations LR Number of poles Contact ratings Operations 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 5 to 240 VDC 10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 100 x 103 2 poles 5 to 110 VDC 5 to 240 VDC 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) 100 x 103 General-purpose Relay G2RS 3 Engineering Data ■ Maximum Switching Capacity Plug-in Relays G2R-1-S G2R-2-S 100 AC inductive load (cosφ = 0.4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 1 0.1 1 10 100 Switching current (A) Switching current (A) 100 AC resistive load DC resistive load 1 0.1 1000 AC inductive load (cosφ = 0.4) 10 DC inductive load (L/R = 7 ms) 1 Switching voltage (V) 10 100 1000 Switching voltage (V) ■ Electrical Service Life Plug-in Relays G2R-2-S 10,000 5,000 1,000 250-VAC/30-VDC resistive load 500 100 250-VAC inductive load (cosφ = 0.4) 30-VDC inductive load (L/R = 7ms) 50 Service Life (x103 operations) Service LIfe (x103 operations) G2R-1-S 5,000 1,000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 250-VAC 50 inductive load (cosφ = 0.4) Switching current (A) Switching current (A) Maximum voltage (%) Ambient Temperature vs. Maximum Coil Voltage DC coil AC coil Note: The maximum voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C) 4 General-purpose Relay G2RS Dimensions Unit: mm (inch) ■ Relays with Plug-in Terminals SPDT Relays Terminal Arrangement/Internal Connections (Bottom View) G2R-1-S, G2R-1-SN, G2R-1-SNI G2R-1-SD, G2R-1-SND, G2R-1-SNDI G2R-1-SD (DC) G2R-1-S 1 13 max. (0.51) 29 (1.14) max. 1 2 5 35.5 max. (1.40) 4 3 G2R-1-SN, G2R-1-SNI (AC) 20 (0.79) 2 5 3 4 G2R-1-SN, G2R-1-SNI (DC) 1 1 5 (0.20) DC 24V 1(0.04) 4.75 (0.19) 0.5 (0.02) 2 5 3 4 2 4 1 2 3 4 8 7 6 5 5 3 7.5 (0.29) G2R-1-SND, G2R-1-SNDI (DC) 5.2 (0.20) 5.2 (0.20) 17.5 (0.69) 1 2 5 3 4 DPDT Relays G2R-2-S, G2R-2-SN, G2R-2-SNI G2R-2-SD, G2R-2-SND, G2R-2-SNDI Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S 29 max. (1.14) G2R-2-SD (DC) 1 2 3 4 8 7 6 5 13 max. (0.51) 35.5 max. (1.40) G2R-2-SN, G2R-2-SNI (AC) 20 (0.79) 0.5 (0.02) 2.5 (0.10) 7.4 (0.29) 5 (0.02) 2.4 (0.09) 8.9 (0.35) 6.2 (0.29) G2R-2-SN, G2R-2-SNI (DC) 1 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 G2R-2-SND, G2R-2-SNDI (DC) 5 (0.02) 19.4 (0.76) 1 2 3 4 8 7 6 5 General-purpose Relay G2RS 5 Track/Surface Mounting Sockets P2RF-05-S Terminal Arrangement (Top View) 38.2 max. (1.50) 36.5 max. (1.44) 11 14 32.6 (1.28) 27.6 (1.09) 22.6 (0.89) 12 24.5 (0.96) 35.4 (1.39) 92.0 max. (3.62) A1 A2 Option (with ejector and label attached) Standard model 28.5 (1.12) 18.0 max. (0.71) 5.3 typical (0.21) 32.6 (1.28) Terminal Arrangement (Top View) 38.2 max. (1.50) P2RF-08-S 36.5 max.(1.44) 21 11 24 14 32.6 (1.28) 27.6 (1.09) 22 12 22.6 (0.89) 3.4 (0.13) typical 24.5 (0.96) 92.0 max. (3.62) 35.4 (1.39) A1 A2 Option (with ejector and label attached) Standard model 28.6 (1.12) 18.0 max. (0.71) 32.6 (1.28) 5.3 typical (0.21) Accessories for P2RF-@-S Socket Bridge Clip and Release Lever 16.8 (0.66) 40.35 (1.59) Note: The color of insulating coating indicates power type. Model P2RM-SR P2RM-SB 6 Power AC DC Color Red Blue General-purpose Relay G2RS 36 (1.42) P2RF-05-E 2 (0.08) Five, M3.5×7 Terminal Arrangement (Top View) 48 max. (1.89) 4 85.5 max. (3.37) 39.5 (1.55) 35.5 (1.40) 3.5 (0.14) dia. hole (14) 3 3.2 (0.13) dia. hole (11) 2 (12) 39.5±0.1 (1.55 ±0.004) 5 5 (0.20) 16.0 max. (0.63) 61 max. (2.40) (A1) (A2) 11.5 (0.45) 2 (0.08) 48.0 max. (1.89) Eight, M3×8 2 (0.08) 39.5 (1.55) (21) (22) (24) 6 3 7 5 2 8 11.5 (0.45) 5 (0.20) Mounting Holes (for Surface Mounting) 4 (11) (12) (14) 3.2 (0.13) dia. hole 39.5±0.1 (1.55±0.004) 3.5 (0.14) dia. hole (A1) (A2) 1 M3 or 3.5 (0.14) dia. hole 61.0 max. (2.40) 16.0 (0.63) max. 2 (0.08) 7(0.28) P2RF-05 Terminal Arrangement (Top View) 3 (0.12) 35.5 (1.40) 85.5 max (3.37) M3 or 3.5 (0.14) dia. 1 Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 1.5 (0.06) Mounting Holes (for Surface Mounting) Five, M3.5 x 8 4 (0.16) dia. holes 71.5 max. (2.81) Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2 (0.16) dia. hole 35.5 (1.40) 30±0.05 (1.18±0.002) 4 (0.16) 19.5 max. (0.77) 19.5 (0.77) 30 max.(1.18) M3 or 3.2 (0.13) dia. hole 54 max. (2.12) P2RF-08 2 (0.08) 7 (0.28) Eight, M3.5 x 8 4 (0.16) dia. holes 71.5 max. (2.89) Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2 (0.16) dia. hole 35.5 (1.40) 30±0.05 (1.18±0.002) 4 (0.16) 19.5 max. (0.77) 19.5 (0.77) 30 max.(1.18) 54 max. (2.12) M3 or 3.2 (0.13) dia. hole General-purpose Relay G2RS 7 Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-@-E P2RF-@ 62.0 (2.44) 66.5 (2.62) 67.0 (2.64) 70.5 (2.77) P2RF-@-S 72.0 (2.83) 65.0 (2.56) 28.6 (1.12) 5.30 (0.21) typical Back-connecting Sockets P2R-05P (1-pole) 4 (0.16) 1(0.04) 7 (0.27) Terminal Arrangement (Bottom View) 14.5 max. (0.57) Mounting Holes Tolerance: ±0.1 4 (0.14) Five, 1.6 (0.06) dia. holes 6 (0.24) 4.5 (0.18) 15 (0.59) 1.2 (0.05) 4 (0.16) 35.5 max. (1.40) 6 (0.24) 4.5 (0.18) 15 (0.59) 3.5 (0.14) 4 (0.16) 1.5 (0.06) 5 (0.20) typical 7 (0.27) 4 (0.16) 7 (2.27) 36.5 max. (1.44) P2R-08P (2-pole) 0.3 4 (0.16) (0.01) 7 (0.27) 14.5 max. (0.57) Terminal Arrangement (Bottom View) Mounting Holes 7.5 (0.29) Eight, 1.3 (0.05) dia. holes 5 (0.20) 5 (0.20) 20 (0.79) 35.5 max. (1.40) 1 (0.04) 5 (0.20) 5 (0.20) 20 (0.79) 2.8 (0.11) 1.5 (0.06) 4.3 (0.17) typical 7.5 (0.29) Terminal plate thickness: 0.3 (0.01) 8 36.5 max. (1.44) General-purpose Relay G2RS 5 (0.20) P2R-05A (1-pole) 7 (0.28) 1.2 (0.05) 0.3 (0.01) 14.5 max. (0.57) Terminal Arrangement (Bottom View) 6.7 (0.26) 3.8 (0.15) 16.7 5 (0.20) (0.66) 35.5 max. (1.40) Panel Cutout Five, 3 x 1.8-dia. holes (0.12 x 0.07) 13.6±0.1 (0.54±0.004) 6 (0.24) 36.5 max. (1.44) Terminal plate thickness: 0.3 7 (0.28) 0.3 (0.01) P2R-08A (2-pole) 7 (0.28) 30.5±0.2 (1.20±0.008) 14.5 max. (0.57) 1.2 (0.05) 5 (0.20) 5 (0.20) 20 (0.79) 35.5 max. (1.40) Recommended thickness of the panel is 1.6 to 2.0 mm 2.6 (0.10) 2.8(0.11) 1.5 (0.06) Eight, 3 x 1.2 (0.12 x 0.05)dia. holes 7.5 (0.30) Terminal plate thickness: 0.3 P2R-057P 14 max. (0.55) 0.7 (0.03) 8.7 (0.34) 36.5 max. (1.44) 16.4 (0.65) 10.4 (0.41) 1(0.04) Terminal Arrangement (Bottom View) 37 max. 29.6 (1.46) (1.17) Mounting Holes 4±0.1 (0.16±0.004) Five, 1.6 (0.06) dia. holes 6±0.1(0.24±0.004) 4.5±0.1 15±0.1(0.59±0.004) (0.18±0.004) 7.4 (0.29) 8.7 (0.34) 4±0.1 (0.16±0.004) 5 (0.20) 7±0.1(0.27±0.004) P2R-087P 14 max. (0.55) 7.5 (0.30) 41 max. (1.61) 16.4(0.65) 1 (0.04) 10.4 (0.41) 37 max. (1.46) 29.1 (1.15) Terminal Arrangement (Bottom View) Mounting Holes 7.5 (0.30) Eight, 1.3 (0.05) dia. holes 5 (0.20) 5 (0.20) 20 (0.79) 8.9 (0.35) 7.4 (0.29) 8.1(0.32) typical 41 max. (1.61) General-purpose Relay G2RS 9 Mounting Height of Relay with Back-connecting Sockets G2R-@P G2R-@A G2R Relay 44.5 (1.75) G2R-@7P G2R Relay 38.0 (1.50) P2R-_P Socket 47.5 (1.87) P2R-_A Socket Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 (0.63) 7.3±0.15 (0.29±0.006) 4.5 (0.18) 4.5 (0.18) 15 (0.59) 25 10 25 (0.98) 25 25 15 (0.59) 1 15(0.59) or 5 (0.20) 10 (0.39) 1,000 (39.37) or 500 (19.68) 24 27 35±0.3 (0.94) (1.38±0.01) (1.06) 27±0.15 35±0.3 25 10 25 (0.98) 1,000 (39.37) 25 25 15 1 (0.04) 10 (0.39) 29.2 (1.15) 1.5 (0.06) It is recommended to use a panel 1.6 to 2.0 mm thick. End Plate Spacer 16 (0.63) PFP-M 10 (0.39) 6.2 (0.24) PFP-S 12 (0.47) 5 (0.20) 1.8 (0.07) 1 (0.04) 50 (1.97) 35.5 35.3 1.8 (1.40) (1.39) (0.07) 11.5 (0.45) 10 (0.39) M4 x 8 pan head screw 34.8 (1.37) 44.3 (1.74) 1.3 (0.05) 4.8 (0.19) 16.5 (0.65) Precautions !Caution Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. !Caution Check that the test button is released before turning ON relay circuits. !Caution If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. !Caution Use an insulated tool when you operate the test button. 10 General-purpose Relay G2RS Precautions for P2RF-@-S Connection • Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. • Do not insert the screwdriver at an angle. Doing so may break the side of the socket and result in a short-circuit. Certain Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all catalogs, manuals or other documents, whether electronic or in writing, relating to the sale of goods or services (collectively, the "Goods") by Omron Electronics LLC and its subsidiary companies ("Seller"). Seller hereby objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. Please contact your Omron representative to confirm any additional terms for sales from your Omron company. 2. Prices. All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at time of shipment. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Seller's payment terms and (ii) Buyer has no past due amounts owing to Seller. 4. Orders. Seller will accept no order less than $200 net billing. 5. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Goods. 6. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Goods sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 7. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Goods sold hereunder and stop any Goods in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 8. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 9. Force Majeure. Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 10. Shipping; Delivery. Unless otherwise expressly agreed in writing by Seller: a. Shipments shall be by a carrier selected by Seller; b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Goods shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Goods shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Goods until the full purchase price is paid by Buyer; d. Delivery and shipping dates are estimates only. e. Seller will package Goods as it deems proper for protection against normal handling and extra charges apply to special conditions. 11. Claims. Any claim by Buyer against Seller for shortage or damage to the Goods occurring before delivery to the carrier must be presented in writing to Seller within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Goods from Seller in the condition claimed. 12. Warranties. (a) Exclusive Warranty. Seller's exclusive warranty is that the Goods will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). Seller disclaims all other warranties, express or implied. (b) Limitations. SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE GOODS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE GOODS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Seller further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Goods or otherwise of any intellectual property right. (c) Buyer Remedy. Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the noncomplying Good or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Good; provided that in no event shall Seller be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Goods unless Seller's analysis confirms that the Goods were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any goods by Buyer must be approved in writing by Seller before shipment. Seller shall not be liable for the suitability or unsuitability or the results from the use of Goods in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. 13. Damage Limits; Etc. SELLER SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE GOODS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Seller exceed the individual price of the Good on which liability is asserted. 14. Indemnities. Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Goods. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Good made to Buyer specifications infringed intellectual property rights of another party. 15. Property; Confidentiality. The intellectual property embodied in the Goods is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Goods are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 16. Miscellaneous. (a) Waiver. No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. (b) Assignment. Buyer may not assign its rights hereunder without Seller's written consent. (c) Amendment. These Terms constitute the entire agreement between Buyer and Seller relating to the Goods, and no provision may be changed or waived unless in writing signed by the parties. (d) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (e) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (f) As used herein, "including" means "including without limitation". Certain Precautions on Specifications and Use 1. Suitability of Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Good in the Buyer's application or use of the Good. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Good. This information by itself is not sufficient for a complete determination of the suitability of the Good in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of this Good, nor is it intended to imply that the uses listed may be suitable for this Good: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Good. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE SELLER'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable Good, or any consequence thereof. 3. Performance Data. Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Good may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller's representative at any time to confirm actual specifications of purchased Good. 5. Errors and Omissions. The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. General-purpose Relay G2RS 11 Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section. OMRON ELECTRONICS LLC OMRON CANADA, INC. OMRON ON-LINE 55 East Commerce Drive, Suite B Schaumburg, IL 60173-5302 885 Milner Avenue Toronto, Ontario M1B 5V8 847-882-2288 416-286-6465 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca Cat. No. J140-E3-01 12 11/03/2.5M General-purpose Relay G2RS Specifications subject to change without notice Printed in USA
G2R-1-SNDC12(S)
物料型号: G2RS系列

器件简介: - G2RS系列是节省空间的电源插入式继电器。 - 标准配置包括机械指示器和铭牌。 - 提供带锁定测试按钮的型号。

引脚分配: - 根据型号不同,引脚分配可能有所变化,但文档中未提供具体的引脚分配图。

参数特性: - 环境友好型设计(无镉、无铅)。 - 高切换功率(1-极:10A)。 - 提供多种插座选项。

功能详解: - 具有可锁定的测试按钮型号。 - 内置机械操作指示器。 - 配备有铭牌。 - 交流类型配备有线圈断开自诊断功能(LED型)。

应用信息: - 适用于需要高切换功率和环境友好设计的场合。

封装信息: - 提供多种安装选项,包括无铅和LED指示器型号。

型号编号结构: - G2R- - - - 1 2 3 4 5 6 7 - 1. 继电器功能:通用 - 2. 极数:1表示1极,2表示2极 - 3. 接触形式:SPDT - 4. 接触类型:单 - 5. 端子类型:S表示插入式 - 6. 分类:通用、LED指示器、二极管等 - 7. 额定线圈电压

订购信息: - 列出了不同分类、外壳等级、线圈额定值和接触形式/型号的详细表格。

额定线圈电压: - 订购时需添加额定线圈电压和"(S)"至型号编号。

配件信息: - 提供了连接插座、无螺钉夹紧端子插座的配件选项。

安装轨道: - 提供了适用的插座安装轨道和配件的描述。

规格: - 包括线圈额定值、线圈电阻、线圈电感、必须操作电压、必须释放电压、最大电压和功耗等详细规格。

接触额定值: - 包括不同极数下的电阻负载、感性负载、额定负载、最大开关电压、最大开关电流和最大开关容量等。

特性: - 包括接触电阻、操作(设定)时间、释放(复位)时间、最大操作频率、绝缘电阻、耐压强度、振动抵抗、冲击抵抗、使用寿命、环境温度、环境湿度和重量等。

认证标准: - 包括UL 508、CSA 22.2 No.0, No.14和IEC/VDE (EN61810)等。

工程数据: - 提供了最大开关容量和电气使用寿命的图表。

尺寸: - 提供了继电器和插座的详细尺寸图。

安装注意事项: - 强调了使用测试按钮和P2RF-@-S连接时的注意事项。

销售条款和条件: - 包括报价、接受、价格、折扣、订单、政府批准、税费、财务、取消、不可抗力、运输、交货、索赔、保修、责任限制、赔偿、财产和保密等条款。

规格和使用注意事项: - 强调了产品使用的适用性、可编程产品、性能数据、规格变更、错误和遗漏等。

保修: - 提供了独家保修声明和限制条件。
G2R-1-SNDC12(S) 价格&库存

很抱歉,暂时无法提供与“G2R-1-SNDC12(S)”相匹配的价格&库存,您可以联系我们找货

免费人工找货