0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G2R2SDC6S

G2R2SDC6S

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Electromechanical Relay 6VDC 69Ohm 5A DPDT(29x13x35.5)mm Plug-In General Purpose Relay

  • 数据手册
  • 价格&库存
G2R2SDC6S 数据手册
General-purpose Relay G2R-@-S (S) Slim and Space-saving Power Plug-in Relay ■ Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements). ■ Lockable test button models available. ■ Built-in mechanical operation indicator. ■ Provided with nameplate. ■ AC type is equipped with a coil-disconnection self-diagnostic function (LED type). ■ High switching power (1-pole: 10 A). LR For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G2R - -S (S) 1 2 3 1. Number of Poles 1:1 pole 2:2 poles 4 5 4. Rated Coil Voltage 5. Mechanical operation indicator and Nameplate (S):Models with mechanical operation indicator and Nameplate 2. Terminals S:Plug-in 3. Classification Blank:General-purpose N:LED indicator D:Diode ND:LED indicator and diode NI:LED indicator with test button NDI:LED indicator and diode with test button Note: Contact your OMRON representative for Relays with gold-plated contacts. Ordering Information When your order, specify the rated voltage. List of Models Classification General-purpose LED indicator LED indicator with test button Coil ratings AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 Diode LED indicator and diode LED indicator and diode with test button DC 6, 12, 24, 48 Contact form SPDT G2R-1-S (S) DPDT G2R-2-S (S) G2R-1-SN (S) G2R-2-SN (S) G2R-1-SNI (S) G2R-2-SNI (S) G2R-1-SD (S) G2R-2-SD (S) G2R-1-SND (S) G2R-2-SND (S) G2R-1-SNDI (S) G2R-2-SNDI (S) Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. 3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. Example: G2R-1-S 12 VDC (S) Rated coil voltage 1 G2R-@-S (S) Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Applicable Relay model Push-In Plus Terminal Blocks No. of poles Back-mounting Socket Screw terminals * Model PCB terminals Solder terminals Models Model Models 1 pole G2R-1-S (S) P2RF-05-PU P2RF-05 P2RF-05-E 2 poles G2R-2-S (S) P2RF-08-PU P2RF-08 P2RF-08-E P2R-05P P2R-057P P2R-05A P2R-08P P2R-087P P2R-08A * The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals. Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU) Short Bars Pitch No. of poles Model * Colors 2 3 7.75 mm PYDN-7.75-030@ Red (R) Blue (S) Yellow (Y) 4 20 15.5 mm Minimum order (quantity) PYDN-7.75-020@ PYDN-7.75-040@ 10 PYDN-7.75-200@ 8 PYDN-15.5-080@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box (@) in the model number with the code for the covering color. Labels Model Manufacturer Minimum order (Box) (quantity per Box) MG-CPM-04 41390N Cembre 1680 (35 Sheet/48 Pieces) Note: PRINTER: MARKINGENIUS MG3 (Ask to your Omron contact for more details on printers) Mounting Tracks Applicable Socket Description Model Minimum order (quantity) 50 cm (l) × 7.3 mm (t): PFP-50N Mounting track Track-connecting Socket 1 m (l) × 7.3 mm (t): PFP-100N 1 m (l) × 16 mm (t): PFP-100N2 End plate *1 PFP-M Spacer PFP-S Back-connecting Socket Mounting plate *2 P2R-P --- 10 1 *1. When mounting DIN rail, please use End Plate (PFP-M).Use the Short Bars for crossover wiring within one Socket or between Sockets. *2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. 2 G2R-@-S (S) Specifications Coil Ratings Rated current* Rated voltage 50 Hz AC 60 Hz Armature OFF 43.5 mA 37.4 mA 253 Ω 0.81 1.55 110 V 9.5 mA 8.2 mA 5,566 Ω 13.33 26.83 120 V 8.6 mA 7.5 mA 7,286 Ω 16.13 32.46 230 V 4.4 mA 3.8 mA 27,172 Ω 72.68 143.90 240 V 4.2 mA 3.7 mA 27,800 Ω 90.58 182.34 Rated current* Coil resistance Coil inductance (H) (ref. value) Armature OFF Must operate voltage Armature ON 24 V Rated voltage DC Coil resistance Coil inductance (H) (ref. value) 87.0 mA 69 Ω 0.25 0.48 12 V 43.2 mA 278 Ω 0.98 2.35 24 V 21.6 mA 1,113 Ω 3.60 8.25 48 V 11.4 mA 4,220 Ω 15.2 29.82 Max. voltage % of rated voltage 80% max. 30% max. Must operate voltage Must release voltage Armature ON 6V Must release voltage 110% Max. voltage % of rated voltage 70% max. 15% min. 110% Power consumption (approx.) 0.9 VA at 60 Hz Power consumption (approx.) 0.53 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current and ±10% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. Contact Ratings Number of poles 1 pole Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load (cosφ = 1) 2 poles Inductive load (cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 7.5 A at 250 VAC; 5 A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 2 A at 250 VAC; 3 A at 30 VDC Rated carry current 10 A 5A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) * 100 mA at 5 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W 10 mA at 5 VDC Note: P level: λ60 = 0.1 x 10-6/operation * This value was measured at a switching frequency of 120 operations per minute. 3 G2R-@-S (S) Characteristics Item 1 pole 2 poles Contact configration SPDT Contact structure Single Contact resistance 100 mΩ max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: Electrical: Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength * 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts; contacts; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Vibration resistance Destruction: Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: Malfunction: 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized Mechanical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) Endurance AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 18,000 operations/hr 1,800 operations/hr (under rated load) Electrical: Ambient temperature Operating: –40°C to 70°C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 20 g Note: Values in the above table are the initial values. * These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets. Approved Standards IEC/VDE (Certificate No. 40015012 EN 61810-1) UL 508 (File No. E41643) Model Contact Coil ratings form Contact ratings Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 × 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 × 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 × 103 5 A, 250 VAC (general use) TV-3 (NO contact only) 25 × 103 CSA 22.2 No.0, No.14 (File No. LR31928) Model Contact Coil ratings form Contact ratings Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 × 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 × 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 × 103 5 A, 250 VAC (general use) 25 × 103 Coil ratings Contact ratings Operations 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 440 VAC (cosφ = 1.0) 10 A, 250 VAC (cosφ = 1.0) 10 A, 30 VDC (0 ms) 100 × 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 250 VAC (cosφ =1.0) 5 A, 30 VDC (0 ms) 100 × 103 LR Number of poles TV-3 (NO contact only) 4 Contact form Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 6 to 240 VDC 10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 100 × 103 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 2 poles 5 to 110 VDC 6 to 240 VDC 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) 100 × 103 G2R-@-S (S) Engineering Data Maximum Switching Power G2R-2-S (S) G2R-1-S (S) 100 Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 1 0.1 1 10 100 Switching current (A) 100 AC resistive load DC resistive load 1 0.1 1000 AC inductive load (cosφ = 0.4) 10 DC inductive load (L/R = 7 ms) 1 Switching voltage (V) 10 100 1000 Switching voltage (V) Endurance G2R-2-S (S) 10,000 5,000 1,000 250-VAC/30-VDC resistive load 500 100 250-VAC inductive load (cosφ = 0.4) 30-VDC inductive load (L/R = 7ms) 50 Switching current (A) Endurance (x103 operations) Endurance (x103 operations) G2R-1-S (S) 5,000 1,000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 250-VAC 50 inductive load (cosφ = 0.4) Switching current (A) Maximum voltage (%) Ambient Temperature vs Maximum Coil Voltage DC coil AC coil Ambient temperature (°C) 5 G2R-@-S (S) Dimensions (Unit: mm) Note: All units are in millimeters unless otherwise indicated. SPDT Relays G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S) G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-1-SD (S) (DC) G2R-1-S (S) 29 max. 1 13 max. 1 2 20 35.5 max. 5 4 3 G2R-1-SN (S), G2R-1-SNI (S) (AC) 4.75 2 5 3 4 4 2 5 3 7.5 0.5 1 5 1 24V 3 4 G2R-1-SN (S), G2R-1-SNI (S) (DC) 1 DC 2 5 G2R-1-SND (S), G2R-1-SNDI (S) (DC) 5.2 5.2 17.5 1 2 5 3 4 DPDT Relays G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S) G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S (S) 1 2 3 4 8 7 6 5 13 max. 2.5 7.4 6 35.5 max. 3 4 8 7 6 5 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 5 19.4 2 1 G2R-2-SND (S), G2R-2-SNDI (S) (DC) 5 1 G2R-2-SN (S), G2R-2-SNI (S) (DC) 8.9 2.4 G2R-2-SN (S), G2R-2-SNI (S) (AC) 6.2 20 29 max. 0.5 G2R-2-SD (S) (DC) 1 2 3 4 8 7 6 5 G2R-@-S (S) Track/Surface Mounting Sockets P2RF-05-PU 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 A2 30.8 28.1 (4.2) (1) Mounting Hole Dimensions A1 (5) 25.6 Two M3 screw holes or two 3.5-dia. holes 108 90 Release lever 35.3 12 (2) 14 (3) 27.35 11 (4) (4.2) 3.9 15.5 34.3 43 52.1 P2RF-08-PU Note: Pull out the hooks to mount the Socket with screws. Note: The numbers in parentheses are traditionally used terminal numbers. 25.6 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 30.8 28.1 (4.2) A2 (1) Mounting Hole Dimensions A1 (8) 25.6 Two M3 screw holes or two 3.5-dia. holes 90 Release lever 35.3 108 12 27.35 (4.2) 3.9 15.5 25.6 34.3 22 (2) (7) 14 24 (4) (5) 11 21 (3) (6) Note: The numbers in parentheses are traditionally used terminal numbers. 43 52.1 Note: Pull out the hooks to mount the Socket with screws. Accessories for P2RF-@-PU Short Bars PYDN-7.75-@@ (7.75 mm) Application L 12 For Contact terminals (common) 18.5 2.25 1.57 PYDN-15.5-080@ (15.5 mm) 12 For Coil terminals 7.75 mm 15.5 mm No. of poles L (Length) 2 15.1 3 22.85 4 30.6 20 154.6 8 115.85 Colors Model * Maximum carry current PYDN-7.75-020@ PYDN-7.75-030@ Red (R) Blue (S) Yellow (Y) PYDN-7.75-040@ 20 A PYDN-7.75-200@ PYDN-15.5-080@ * Replace the box (@) in the model number with the code for the covering color. 3.90 115.85 2.25 Pitch 3.90 18.5 Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets. 2. When using short bar to coil terminals of PYF-@@-PU, make sure to use PYDN-31.0-080@ (31 mm). When using short bar to coil terminals of P2RF-@@-PU, make sure to use PYDN-15.5-080@ (15.5 mm). 1.57 7 G2R-@-S (S) P2RF-05-E 7±0.2 Five, M3.5´7 2 48 max. Terminal Arrangement (Top View) 4 (12) 39.5 3 35.5 85.5 max. Mounting Holes (for Surface Mounting) 3.2-dia. hole (11) 2 (14) 39.5±0.1 3.5-dia. hole M3 or 3.5-dia. hole 5 (A1) (A2) 4 1 11.5 61 max. 16.0 max. Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 6 +0.2 −0.1 2 Terminal Arrangement (Top View) 2 1.5 Eight, M3´8 48.0 max. Mounting Holes (for Surface Mounting) 3 39.5 (21) (22) (24) 6 3 7 5 2 4 (11) (12) (14) 3.2-dia. hole 35.5 39.5±0.1 85.5 max. 3.5-dia. hole 8 (A1) (A2) 4 61.0 max. 1 M3 or 3.5-dia. hole 11.5 16.0 max. P2RF-05 2 7 Terminal Arrangement (Top View) Five, M3.5 x 8 4-dia. holes Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 30±0.05 4 19.5 30 max. 19.5 max. M3 or 3.2-dia. hole 54 max. P2RF-08 2 7 Eight, M3.5 x 8 4-dia. holes Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 30±0.05 4 19.5 max. 19.5 30 max. 54 max. 8 M3 or 3.2-dia. hole G2R-@-S (S) Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-05-PU P2RF-08-PU G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-05ーPU Socket P2RF-08ーPU Socket 63.6 63.6 28.1 28.1 (3.9) (3.9) P2RF-@ P2RF-@-E G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-@-E Socket P2RF-@ Socket 67.0 70.5 66.5 62.0 Back-connecting Sockets P2R-05P (1-pole) 4 1 Terminal Arrangement (Bottom View) 14.5 max. 7 Mounting Holes Tolerance: ±0.1 4 6 4.5 6 35.5 max. 15 Five, 1.6-dia. holes 4.5 1.2 4 15 3.5 4 1.5 (5) 4 7 7 36.5 max. P2R-08P (2-pole) 4 0.3 14.5 max. 7 Terminal Arrangement (Bottom View) Mounting Holes 7.5 Eight, 1.3-dia. holes 5 5 35.5 max. 20 1 5 5 20 2.8 1.5 (4.3) 7.5 Terminal plate thickness: 0.3 36.5 max. 9 G2R-@-S (S) 4.5 P2R-05A (1-pole) 7.5 14.5 max. 1.2 0.3 Terminal Arrangement (Bottom View) 6.7 3.8 35.5 max. 5 16.7 Panel Cutout Five, 3 x 1.8-dia. holes 13.6±0.1 6 36.5 max. Terminal plate thickness: 0.3 30.5±0.2 6.5 7.5 P2R-08A (2-pole) 14.5 max. 1.2 0.3 5 5 35.5 max. Recommended thickness of the panel is 1.6 to 2.0 mm 20 2.6 2.8 1.5 Eight, 3 x 1.2-dia. holes 7.5 Terminal plate thickness: 0.3 P2R-057P (1-pole) 0.7 14 max. 8.7 36.5 max. 1 Terminal Arrangement (Bottom View) 16.4 10.4 3.5 1 Mounting Holes 4±0.1 6 4.5 15 37 max.29.6 1 8.7 Five, 1.6-dia. holes 6±0.1 4 8.75 4.5±0.1 15±0.1 4±0.1 5 7.4 7±0.1 41 max. P2R-087P (2-pole) 14 max. 7.5 1 Terminal Arrangement (Bottom View) 16.4 10.4 3.5 0.3 7.5 5 5 37 max. 29.1 20 1 Eight, 1.3-dia. holes 5 5 8.1 8.9 Mounting Holes 20 7.4 (8.1) 41 max. Mounting Height of Relay with Back-connecting Sockets P2R-@P P2R-@A P2R-@7P G2R-@-S (S) Relay G2R-@-S (S) Relay 44.5 P2R-@P Socket 10 38.0 47.5 P2R-@A Socket G2R-@-S (S) Relay P2R-@7P Socket G2R-@-S (S) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 15 25 25 25 25 10 15 (5) 10 1,000 (500) 35±0.3 27 27±0.15 35±0.3 15 1 25 25 15 25 25 10 10 24 29.2 1 1.5 1,000 It is recommended to use a panel 1.6 to 2.0 mm thick. End Plate Spacer 10 6.2 PFP-M PFP-S 16 12 5 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Mounting Plate P2R-P 90 R2.25 10-Ellipse hole 4.5 13.6 3.4 49 42±0.1 30.5 18±0.15 18±0.15 18±0.15 18±0.15 Square hole 9±0.1 72±0.2 9±0.1 t=1.6 mm Safety Precautions Be sure to read the Common Precautions for All Relay in the website at the following URL: http://www.ia.omron.com/. Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets. Refer to PYF-@@-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets. Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Cation • Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. • Check that the test button is released before turning ON relay circuits. • If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. • Use an insulated tool when you operate the test button. 11 OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. J226-E1-01 1118(1118)
G2R2SDC6S 价格&库存

很抱歉,暂时无法提供与“G2R2SDC6S”相匹配的价格&库存,您可以联系我们找货

免费人工找货