G2RG-X
PCB Power Relay
Power Relay with 500 VDC 10 A
Switching Capacity (2 poles series
wiring with 3.0 mm contact gap)
• Achieves 500 VDC 10 A switching capacity used with 2 pole series wiring
• 3.0 mm contact gap (2 poles series wiring)
• Offers high insulation with insulation distance above 8 mm and
impulse withstand voltage of 10 kV between coil and contacts.
• UL and TÜV certified
Model Number Legend
Application Example
• Energy storage system
G 2 R G - 2 A@ -X
—— —
1 2 3
1. Number of Poles 2. Contact Form 3. Enclosure rating
2: 2-pole
A: N.O. contact
Blank: Flux protection
DPST-NO (2a)
Ordering Information
Characteristics
Contact
form
Enclosure
rating
Terminal
type
Model
DPST-NO
(2a)
Flux
protection
PCB
terminals
G2RG-2A-X
Rated coil
Minimun
voltage packing unit
12 VDC
24 VDC
60 pcs/tray
Note. When ordering, add the rated coil voltage (V) to the model number.
Example: G2RG-2A-X DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
Contact resistance *1
100 mΩ max.
Operate time
15 ms max.
Release time
5 ms max.
Insulation resistance *2
1,000 MΩ min.
Between coil
and contacts
Dielectric
strength
Ratings
Rated voltage
Rated
current
(mA)
Must-operate Must-release Maximum
Coil
Power
voltage
voltage
voltage
resistance
consumption
(V)
(V)
(V)
(Ω)
(mW)
% of rated voltage
12 VDC
66.6
180
24 VDC
33.3
720
80% max.
10% min.
110%
(at 23°C)
Approx.
800
Note 1. The rated current and coil resistance are for a coil temperature of 23°C
and have a tolerance of ±10%.
Note 2. The operating characteristics given in the above table are for a coil
temperature of 23°C.
Note 3. The maximum allowable voltage is the maximum possible value of the
voltage that can be applied to the relay coil.
Impulse withstand voltage
Vibration
resistance
Shock
resistance
Durability
Contacts (2-pole Series Wiring)
Item
Load
1 pole series wiring
Contact type
Single
Contact material
Ag-alloy (Cd free)
Rated load (Resistive load)
10 A at 300 VDC
Rated carry current
8 A (85°C), 10 A (65°C)
Maximum switching voltage 300 VDC
Maximum switching current
10 A
500 VDC
1,000 VAC, 50/60 Hz for 1 min
10 kV (1.2 x 50 μs)
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
200 m/s2 when energized
Mechanical
1,000,000 operations min.
(at 18,000 operations/hr)
Electrical *3
(Resistive load)
1-pole series wiring:
10,000 operations at 300 VDC 10 A
2-poles series wiring:
10,000 operations at 500 VDC 10 A
30,000 operations at 500 VDC 1 A
(switching frequency 1 sec ON-9 sec OFF at 85 °C)
2 pole series wiring
10 A at 500 VDC
5,000 VAC, 50/60 Hz for 1 min
Between
contacts of
3,000 VAC, 50/60 Hz for 1 min
different polarity
Between
contacts of the
same polarity
Coil
Item
G
2
R
G
I
X
Ambient operating
temperature
-40 to 85 °C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 22 g
Note. The above values are initial values (at an ambient temperature of 23°C.)
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. It is a value
between each contact terminal.
*2. Measurement conditions: Measured with a 500 VDC megohmmeter at the
same places as the dielectric strength.
*3. This is the case when diodes and Zener diodes are used. Connect the
relay coil to the diode and the Zener diode.For details, please refer to
"Connection of diodes to the operating coil" on page 3.
1
G2RG-X
PCB Power Relay
Dimensions
CAD Data
Please visit our website, which is noted on the last page.
G2RG-2A-X
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
23.5 max.
(22.8)*
29 max.
(28.6)*
13.5 max.
(12.8)*
8.6
(Unit: mm)
5
Six, 1.3-dia. holes
7.5
29.5 max.
(28.5)*
17.2
(2.1)
3.5
20
0.5
0.2
0.3
1
1
* Average value
CAD Data
Circuit Diagrams
1 pole series wiring
G
2
R
G
I
X
2-poles series wiring
+
+
−
−
−
−
+
+
Note. The contacts have polarity. Exercise caution.
The diode and zener diode are for coil surge absorption. (The coil has no polarity.)
Approved Standards
The approved rated values for international standards are different to the individually specified characteristic values. Be sure to confirm
that required standards are satisfied before actual use.
UL Recognized:
Model
(File No. E41643)
Contact form
Coil ratings
2a, 1 pole series wiring
G2RG-2A-X
2a, 2-poles series wiring
EN/IEC, TÜV Certified Model
Model
Contact form
12, 24 VDC
2
2a, 2-poles series wiring
Number of test
operations
10 A, 300 VDC (Resistive) 85°C
10,000
10 A, 500 VDC (Resistive) 85°C
10,000
1 A, 500 VDC (Resistive) 85°C
30,000
(Approval/No. R50468711)
Coil ratings
2a, 1 pole series wiring
G2RG-2A-X
Contact ratings
12, 24 VDC
Contact ratings
Number of test
operations
10 A, 300 VDC (Resistive) 85°C
10,000
10 A, 500 VDC (Resistive) 85°C
10,000
1 A, 500 VDC (Resistive) 85°C
30,000
G2RG-X
PCB Power Relay
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Dropping
Correct Use
Differences with the G2R
The G2RG-2A-X has the same terminal arrangement as the
G2R-2A4 but the switching capacity and electrical endurance are
different. Confirm that correct operation is possible in the actual
operating conditions before using in applications.
Handling
The enclosure rating of this product is flux protection. Therefore,
do not wash with water or detergent.
Mounting
The contacts of this product have polarity. Be sufficiently careful
because incorrect wiring may result in a failure to break the
circuit.
Install the product in a dry location with little dust and corrosive
gas.
Use in high temperature and humidity or an atmosphere
containing corrosive gas may lead to the relay itself failing or
suffering burn damage caused by performance deterioration due
to the influence of condensation or corrosive materials.
Do not use this product if it has been dropped.
Electrical endurance
Since this product is specifically for high DC voltages, the final
failure mode is failure to break the circuit, and in a worse-case
scenario, burning may extend to surrounding components.
Do not exceed the specified ratings or number of operations
during use, or use the product for any application other than high
DC voltages.
Implement a safety circuit and other safety measures to
minimize the risk in the event of a failure.
The electrical endurance of this product is the number of load
switching operations with a resistive load under the standard
testing conditions specified by OMRON.
The coil drive circuit, ambient environment, switching frequency,
or load condition (use under an inductive load or capacitor load)
may reduce the endurance and lead to a failure to break the
circuit. Always confirm operation with the actual equipment.
Connection of diodes to the operating coil
Connect a diode and zener diode to the relay coil (refer to the
following figure).
The diodes are for coil surge absorption. Switching performance
may be affected if only a diode is used, so use in combination
with a zener diode.
The coil has no polarity. Connect the diodes in the reverse
polarity of the voltage applied to the coil.
The recommended zener voltage of the zener diode is three
times the rated coil voltage.
Diode
Relay Coil
Zenor Diode
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Device & Module Solutions Company
Regional Contact
Americas
https://components.omron.com/us
Asia-Pacific
https://components.omron.com/ap
Korea
https://components.omron.com/kr
Europe
https://components.omron.com/eu
China
https://components.omron.com.cn
Japan
https://components.omron.com/jp
© OMRON Corporation 2020-2023 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. K333-E1-03
0823 (0720)
3
G
2
R
G
I
X