G2RL-1-DC24

G2RL-1-DC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    DIP5

  • 描述:

    RELAY GEN PURPOSE SPDT 12A 24V

  • 数据手册
  • 价格&库存
G2RL-1-DC24 数据手册
G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments • A wide variety of single pole, double pole, high-capacity (16 A) type and high-sensitivity type (250 mW) Relays are available. • Low profile; 15.7 mm max. in height. • Conforms to VDE (EN61810-1), UL508 and CSA22.2. • IEC/EN 60335-1 conformed. (-HA Model) • Satisfies ambient operating temperature requirement of 85°C and 105°C (-CV Model). • Clearance and creepage distance: 8 mm / 8 mm min. • Coil insulation system: Class F (UL1446). • G2RL-1(A)-E-ASI: TV3 Rating models available. • IEC/EN 60079-15 conformed (Except G2RL-1(A)-H, G2RL-1A-E-CV(-HA) Models). ■Application Examples • Home appliances • OA equipments • Industrial machinery RoHS Compliant ■Model Number Legend G 2 R L G2RL- @ @@ -@ -@ - @- @ ——— — — — — 1 2 3 4 5 1. Number of poles 1 : 1 pole 2 : 2 pole 2. Contact Form None : SPDT (1c) A : SPST-NO (1a) 6 7 3. Enclosure rating None : Flux protection 4 : Sealed 4. Classification None : Standard E : High-capacity H : High-sensitivity 5. Contact Material None : Standard (Ag-alloy, Cd free) ASI : AgSnIn 6. Special Requirement None : Standard CV : 16 A, pinning 5 mm, switching at 105°C PW : Coil Holding Voltage type 7. Market Code None : General purpose HA : Home Appliance according to IEC/EN60335-1 ■Ordering Information Terminal Shape Market Code Classification Contact form SPST-NO (1a) SPDT (1c) Standard DPST-NO (2a) DPDT (2c) Model Flux protection G2RL-1A Sealed G2RL-1A4 Flux protection G2RL-1 Sealed G2RL-14 Flux protection G2RL-2A Sealed G2RL-2A4 Flux protection Sealed General Purpose Rated coil voltage Minimum packing unit 5, 12, 24, 48 VDC G2RL-2 G2RL-2-ASI G2RL-24 G2RL-1A-E SPST-NO (1a) PCB terminals Enclosure rating Flux protection G2RL-1A-E-CV Sealed High-capacity Flux protection Standard SPST-NO (1a) High-capacity G2RL-14-E G2RL-1-H SPDT (1c) G2RL-1-HA DPST-NO (2a) SPST-NO (1a) SPDT (1c) 5, 12, 24 VDC 5, 12, 24, 48 VDC G2RL-1A-H SPDT (1c) DPDT (2c) Home Application 20 pcs/tube 5, 12, 24, 48 VDC G2RL-1-E-ASI G2RL-1-E-PW Sealed 5, 12, 24 VDC G2RL-1A4-E G2RL-1-E SPDT (1c) High-sensitivity G2RL-1A-E-ASI Flux protection G2RL-2A-HA G2RL-2-HA 5, 12, 24 VDC G2RL-1A-E-HA G2RL-1A-E-CV-HA G2RL-1-E-HA Note 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case will be marked as @@VDC. Note 2. Place your order in tube (20 pcs/tube) units. Note 3. Contact your OMRON sales representative for sealed models. 1 G2RL PCB Power Relay ■Ratings ●Coil Item Standard, HighCapacity Highsensitivity Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC 5 VDC 12 VDC 24 VDC Rated current (mA) Coil resistance (Ω) 80.0 33.3 16.7 8.96 50 20.8 10.42 Must operate voltage Must release voltage (V) (V) % of rated voltage 62.5 360 1,440 5,358 96 576 2,304 10% min. 10 to 32%* 70% max. 75% max. Max. voltage (V) Power consumption (mW) Approx. 400 Approx. 100* 130% (at 85°C) 10% Approx. 430 Approx. 250 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. * These numbers are only for -PW type. Power consumption with Holding Voltage is approx.100mW. Please confirm the detail in page 6 Coil Voltage Reduction (Holding Voltage). ●Contacts: Flux Protection Type Classification Item Model Standard type (resistive load) 1-pole High-capacity type (resistive load) High-sensitivity type (resistive load) 2-pole 1-pole Contact type Single Contact material Rated load G 2 R L Rated carry current Ag-alloy (Cd free) 12 A at 250 VAC 12 A at 24 VDC (See note) 8 A at 250 VAC 8 A at 30 VDC (See note) 16 A at 250 VAC 16 A at 24 VDC (See note) 12 A (See note) 8 A (70°C)/5 A (85°C) (See note) 16 A (See note) 12 A 8A Max. switching voltage Max. switching current 10 A at 250 VAC (See note) 10 A (See note) 440 VAC, 300 VDC Failure rate (P level) (reference value*) 16 A 10 A 40 mA at 24 VDC * This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on sealed models. ■Characteristics ●Flux Protection Type Classification Item Number of poles Contact resistance *1 Operate (set) time Release (reset) time Insulation resistance *2 Between coil and contacts Between contacts Dielectric of the same strength polarity Between contacts of different polarity Impulse withstand voltage Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Standard type 1-pole High-capacity type 2-pole High-sensitivity type 1-pole 100 mΩ max. 15 ms max. 5 ms max. 1,000 MΩ min. 5,000 VAC, 50/60 Hz for 1min 1,000 VAC, 50/60 Hz for 1min − 2,500 VAC, 50/60 Hz for 1min − 10 kV (1.2 x 50 μs) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 Energized: 100 m/s2, De-energized: 100 m/s2 20,000,000 operations (at 18,000 operations/hr) G2RL-1A-E(-ASI,-HA), G2RL-1-E(-ASI,-HA, -PW): G2RL-1A, G2RL-1(-HA): G2RL-2(A)(-HA), G2RL-2-ASI: 30,000 operations at 250 VAC, 16 A Durability Electrical *3 G2RL-1(A)-H: 30,000 operations at 24 VDC, 16 A 50,000 operations at 250 VAC, 12 A 30,000 operations at 250 VAC, 8 A 50,000 operations at 250 VAC, 10 A (resistive load) 30,000 operations at 24 VDC, 12 A 30,000 operations at 30 VDC, 8 A G2RL-1A-E-CV(-HA): 50,000 operations at 250 VAC, 16 A at 105°C -40°C to 85°C (with no icing or condensation) Ambient operating temperature -40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV Ambient operating humidity 5% to 85% (with no icing or condensation) Weight Approx. 12 g Note 1. Values in the above table are the initial values at 23°C. Note 2. Contact your OMRON sales representative for sealed models. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour. 2 G2RL PCB Power Relay ■Engineering Data AC resistive load 10 5 AC resistive load 10 5 50 5 DC resistive load 1 1 1 0.5 0.5 0.5 0.1 0.1 0.1 5 10 20 30 50 100 0 500 1,000 5 10 20 30 50 100 AC resistive load 10 5 DC resistive load Rated Carry Current (A) ●Ambient Temperature vs. Rated Carry Current 50 20 1-pole High-capacity type 16 15 1-pole Standard type 12 1-pole High-sensitivity type 1 5 10 20 30 50 100 ●Ambient Temperature vs. Maximum Coil Voltage 250 200 180 G 2 R L G2RL-1A-E-CV 150 10 130 8 110 100 Other type 2-pole type 0.5 500 1,000 Switching voltage (V) Switching voltage (V) Switching voltage (V) High-sensitibity type 0 500 1,000 Maximum coil voltage (%) 0 AC resistive load 10 DC resistive load DC resistive load Switching current (A) 2-pole type 50 Switching current (A) 1-pole High-capacity type 50 Switching current (A) Switching current (A) ●Maximum Switching Capacity 1-pole Standard type 5 50 0.1 0 5 10 20 30 50 100 500 1,000 Switching voltage (V) 0 10 20 30 40 50 60 70 80 85 90 100 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 85 90 100 105 110 Ambient temperature (°C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Must operate/must release voltage (percentage of rated voltage) (%) ●Ambient Temperature vs. Must Operate and Must Release Voltages 100 Sample: 90 G2RL-14-E 24 VDC Number of relays: 5 pcs 80 Must operate voltage Must release voltage max. X min. 70 60 50 40 max. X min. 30 20 10 0 20 40 60 80 100 120 Ambient temperature (°C) 3 G2RL PCB Power Relay ●Shock Malfunction 1-pole type Y NO contact 2-pole type Y 1,000 X' 1,000 NO contact Sample: G2RL-14 12 VDC Number of Relays: 5 pcs X' Test conditions: Shock is applied 1,000 in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 1,000 100 m/s2 Z 1,000 130 1,000 Z' 1,000 X NC contact 1,000 Y' Z 1,000 150 1,000 X NC contact Z' Y 1,000 Shock direction X X' Y Z Z' Unit: m/s2 Sample: G2RL-24 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 1,000 Y' Shock direction X X' Z Z' Unit: m/s2 Y' Y' ■Electrical Endurance Data (Reference Value) G 2 R L G2RL-1-E 8 A 250 VAC (cosφ=0.4) 8 A 30 VDC (L/R=7 ms) 200,000 operation min. (N.O.) 10,000 operation min. (N.O.) G2RL-1 5 A 250 VAC (cosφ=0.4) 5 A 30 VDC (L/R=7 ms) 150,000 operation min. (N.O.) 10,000 operation min. (N.O.) G2RL-2 8 A 250 VAC (cosφ=1) 8 A 30 VDC G2RL-1A-E Pilot duty (A300), 250 VAC 250,000 operation min. Pilot duty (A300), 125 VAC 150,000 operation min. 30,000 operation min. 10,000 operation min. Note. The results shown reflect values at ambient temperature 23°C. Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the electrical endurance under your test condition. ■Dimensions (Unit: mm) G2RL-1A, G2RL-1A4, G2RL-1A-H PCB Mounting Holes (Bottom View) 3.5 12.7 max. (12.5)* 29 max. (28.8)* Four, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 * Average value G2RL-1, G2RL-14, G2RL-1-H, G2RL-1-HA PCB Mounting Holes (Bottom View) 3.5 3.5 12.7 max. (12.5)* 29 max. (28.8)* Five, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 0.5 * Average value G2RL-1A-E(-HA), G2RL-1A4-E, G2RL-1A-E-CV(-HA), G2RL-1A-E-ASI PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 4 6 5 7.5 15.7 max. (15.5)* 8 (2.3) 0.5 3.5 0.5 0.8 0.5 * Average value 4 20 (No coil polarity) G2RL PCB Power Relay G2RL-1-E(-ASI, -HA, -PW) G2RL-14-E PCB Mounting Holes (Bottom View) 5 5 12.7 max. (12.5)* 29 max. (28.8)* Eight, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 * Average value G2RL-2A(-HA), G2RL-2A4 PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 4 8 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 * Average value G2RL-2(-HA), G2RL-24, G2RL-2-ASI PCB Mounting Holes (Bottom View) 5 5 12.7 max. (12.5)* 29 max. (28.8)* G 2 R L Terminal Arrangement/ Internal Connections (Bottom View) Eight, 1.3-dia. holes (2.5) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 * Average value ■Approved Standards • The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. UL Recognized: CSA Certified: Model (File No. 41643) (File No. LR31928) Contact form G2RL-1A G2RL-1(-HA) G2RL-1A-E(-HA) G2RL-1-E(-HA, -PW) G2RL-1A-E-ASI G2RL-1-E-ASI G2RL-1A-E-CV(-HA) G2RL-1A-H G2RL-1-H G2RL-2A(-HA) G2RL-2(-HA) SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPST-NO (1a) SPDT (1c) DPST-NO (2a) DPDT (2c) G2RL-2-ASI DPDT (2c) Coil ratings 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC Contact ratings 12 A, 250 VAC (General Use) 40°C 12 A, 24 VDC (Resistive) 40°C 16 A, 250 VAC (General Use) 40°C 16 A, 24 VDC (Resistive) 40°C 16 A, 250 VAC (Resistive) 85°C TV-3 40°C 16 A, 250 VAC (Resistive) 105°C 10 A, 250 VAC (General Use) 40°C 10 A, 24 VDC (Resistive) 40°C 8 A, 277 VAC (General Use) 40°C 8 A, 30 VDC (Resistive) 40°C 8 A, 250 VAC (Resistive) 85°C 8 A, 30 VDC (Resistive) 85°C Number of test operations 100,000 50,000 100,000 50,000 30,000 25,000 100,000 50,000 100,000 15,000 15,000 5 G2RL PCB Power Relay EN/IEC, VDE Certified (Certificate No. 119650) Model Contact form G2RL-1A G2RL-1(-HA) SPST-NO (1a) SPDT (1c) G2RL-1A-E(-HA) G2RL-1-E(-HA, -PW) SPST-NO (1a) SPDT (1c) G2RL-1A-E-ASI G2RL-1-E-ASI G2RL-1A-E-CV(-HA) SPST-NO (1a) SPDT (1c) SPST-NO (1a) G2RL-1A-H G2RL-1-H SPST-NO (1a) SPDT (1c) G2RL-2A (-HA) DPST-NO (2a) G2RL-2 (-HA) DPDT (2c) G2RL-2-ASI DPDT (2c) CQC Certified Contact form G2RL-1A SPST-NO (1a) G2RL-1(-HA) SPDT (1c) 12 A, 250 VAC (cosφ=1) 85°C 12 A, 24 VDC (L/R=0 ms) 85°C AC15: 3 A at 240 VAC at room temperature DC13: 2.5 A at 24 VDC, 50ms at room temperature 16 A, 250 VAC (cosφ=1) 85°C 16 A, 24 VDC (L/R=0 ms) 85°C 5,12,24,48 VDC AC15: 3 A at 240 VAC (NO) at room temperature, 1.5 A at 240V AC (NC) at room temperature DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature Number of test operations 100,000 5,12,24,48 VDC 5,12,24,48 VDC 16 A, 250 VAC (cosφ=1) 85°C 5,12,24,48 VDC 16 A, 250 VAC (cosφ=1) 105°C 10 A, 250 VAC (cosφ=1) 85°C 5,12,24 VDC 10 A, 250 VAC (cosφ=1) 40°C 10 A, 24 VDC (L/R=0 ms) 85°C 8 A, 250 VAC (cosφ=1) 85°C 8 A, 30 VDC (L/R=0 ms) 85°C 5,12,24,48 VDC AC15: 1.5 A at 240VAC at room temperature DC13: 2 A at 30 VDC, 50ms at room temperature 8 A, 250V AC (Resistive) 85°C 5,12,24,48 VDC 8 A, 30V DC (Resistive) 85°C G2RL-1A-E(-ASI, -HA) G2RL-1A-E-CV(-HA) SPST-NO (1a) G2RL-1-E(-ASI,-HA,-PW) SPDT (1c) G2RL-2A (4)(-HA) DPST-NO (2a) G2RL-2(-ASI,-HA) DPDT (2c) Coil ratings 5 to 48 VDC 5 to 48 VDC 5 to 48 VDC Creepage distance Clearance distance Insulation material group Type of insulation coil-contact circuit open contact circuit Rated Insulation voltage Pollution degree Rated voltage system Over voltage category Category of protection according to IEC 61810-1 Glow wire according to IEC 60335-1 Tracking Index of relay base 6 Contact ratings 6,000 30,000 15,000 6,000 30,000 100,000 50,000 100,000 50,000 30,000 15,000 6,000 15,000 15,000 (Certificate No. CQC17002171904) Model G 2 R L Coil ratings Contact ratings 12 A, 250 VAC (cosφ=1) at room temperature 12 A, 24 VDC (L/R=0 ms) at room temperature 12 A, 250 VAC (cosφ=1) at room temperature 12 A, 24 VDC (L/R=0 ms) at room temperature 16 A, 250 VAC (cosφ=1) at room temperature 16 A, 24 VDC (L/R=0 ms) at room temperature 16 A, 250 VAC (cosφ=1) at room temperature 16 A, 24 VDC (L/R=0 ms) at room temperature 8 A, 250 VAC (cosφ=1) at room temperature 8 A, 30 VDC (L/R=0 ms) at room temperature 3 A, 250 VAC (cosφ=1) at room temperature 3 A, 30 VDC (L/R=0 ms) at room temperature 8 mm min. 8 mm min. IIIa Reinforced Micro disconnection 250 V 3 (Flux protection / Sealed) 250 V / 400 V (Flux protection) III RT II (Flux protection) / RT III (Sealed) GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) PTI 250 V min. (housing parts) Number of test operations 50,000 30,000 50,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 G2RL PCB Power Relay ■Precautions • Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ● Mounting Position Compared to G2R Model • Although the G2RL model and the G2R model are both low profile Relays, their characteristics such as switching capacity are different. Be sure to check operation under the actual operating conditions before use. ● Cleaning • The G2RL model is flux-resistant with two sealing holes on the case. Thus, do not clean the Relay by boiling or soaking in water. Consult your Omron sales representative for sealed type Relay. ● Using Relays in an Atmosphere Containing Corrosive Gas • Do not use Relays in an atmosphere containing corrosive gas (sulfuric or organic gas).Otherwise, connection failure due to corrosion on the contact surface may lead to functional faults. ●Coil Voltage Reduction (Holding Voltage) after Relay Operation • If the coil voltage is reduced to the holding voltage after Relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below. • A voltage of at least 50% of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level. G 2 R L 100% (Rated voltage) 50% (Holding voltage) 100ms min. Applied coil voltage * Rated voltage 100% Holding voltage 50% Coil resistance* 62.5Ω (5 VDC) 360Ω (12 VDC) 1,440Ω (24 VDC) Power consumption Approx. 400 mW Approx. 100 mW The coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%. Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Americas https://www.components.omron.com/ Asia-Pacific https://ecb.omron.com.sg/ Korea https://www.omron-ecb.co.kr/ Europe http://components.omron.eu/ China https://www.ecb.omron.com.cn/ Japan https://www.omron.co.jp/ecb/ © OMRON Corporation 2007-2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. J117-E1-14 0719(0207)(O) 7
G2RL-1-DC24 价格&库存

很抱歉,暂时无法提供与“G2RL-1-DC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G2RL-1-DC24
  •  国内价格
  • 30+19.91388
  • 100+14.07393

库存:0

G2RL-1-DC24
    •  国内价格
    • 1+9.35280
    • 10+7.92720
    • 30+7.13880
    • 100+6.26400
    • 500+5.25960
    • 1000+5.07600

    库存:0