Offering the global standard in safety.
Meeting our customers’ every need
with numerous variations.
Electrical
Mechanical
Relay
Selection Guide
Signal Relay
Power Relay
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2007-2018 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. Y225-E1-02
0318(0317)(O)
PCB Relay
PCB Relay Types
Introduction of Main Types
Signal Relay
We largely divide relays based on the maximum switching current value.
Signal Relay
Power Relay
Relays with less than 2 A maximum switching current value
Model
Relays larger than 2 A maximum switching current value
Features
Type Selection List (Best Selection)
Signal Relay
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
1c
2c
1A
2A
3A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
PCB terminal
Surface-mounting
Terminals
G5V-1
○
○
G5V-2
G6E
○
○
○
○
○
○
○
○
○
○
○
○
G6A
G6S
G6J-Y
G6K
G6K-RF
(-S,-T)
G6K-RF-V
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Power Relay
Item
Contact form
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
1a
1c
1a1b
2a
2b
3A
5A
7A
8A
10 A
15 A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
PCB terminal
Tab terminal
Item
Contact form
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
2
G6K
G6K(U)-2F(P)-RF(S,-T)
G6K-2F-RF-V
Ultra-small low
profile relay
Low power
consumption
1 GHz/3 GHz range
Ultra-small high
frequency relay
8-GHz Band
High Frequency
Relay for Differential
Transmission
G6J-Y
Small general purpose
Ultra-small slim relay
relay
High density
High dielectric
application possible
strength, high current
Shape
Item
Contact form
G6S
1a
1c
1a1b
2a
2c
4A
5A
8A
10 A
12 A
15 A
16 A
20 A
25 A
30 A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
Enclosed
PCB terminal
Tab terminal
Screw terminal
Contact form
2c
2c
2c
2c
2c
Max. switching
current
2A
1A
1A
1A
1A
Coil power
consumption
Approx. 140 to 200
mW
Approx. 140 to 230
mW
Approx. 100 mW
Approx. 100 mW
Approx. 100 mW
Dielectric strength
(Between coil and
contacts)
2,000 VAC
(Impulse withstand
voltage: 2.5 kV)
1,500 VAC
(Impulse withstand
voltage: 2.5 kV)
1,500 VAC
(Impulse withstand
voltage: 2.5 kV)
750 VAC
AC350V
Power Relay
G6DN
○
○
G5NB
(-EL)
○
G5Q(-EL/EL2/-EL3)
○
○
○
G6D
G6B
G6RN
G6RL
G5LE
G5CA
G6C
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
G4W
G4A
G2RL
G5RL
○
○
○
○
○
○
○
○
○
○
○
○
G5RL
-U/-K
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ (N.C.)
○
○
○
G2RG
○
○ (N.O.)
○ (N.O.)
G6DN
G5NB(-EL)
G5Q(-EL/-EL2/-EL3)
G2RL
Small, slim power relay
with 1-pole 5 A switching
Small general purpose relay
with 1-pole switching at
7 A max
Small power relay
with 1-pole 10 A switching
Low profile power relay
with 1-pole 10 A/16 A
throw/2-pole 5 A switching
Contact form
1a
1a
1a, 1c
1a, 1c, 2a, 2c
Max. switching
current
5A
AC: 7 A, DC: 5 A (-EL)
3 A (standard type)
10 A
10 A/16 A (1a, 1c)
5 A (2a, 2c)
Approx. 110 mW
Approx. 200 mW
Approx. 200 mW
Approx. 400 mW
5 to 24 VDC: Approx. 400 mW
48 VDC: Approx. 430 mW
Features
Shape
○
○ (N.C.)
○
Model
○
○
○
○
○
○
○
○
○
G2R
G7L
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
G7L
-PV
G7L
-X
○
○
Coil power
consumption
Dielectric strength
(Between coil and
contacts)
3,000 VAC
4,000 VAC
4,000 VAC
5,000 VAC
(Impulse withstand voltage: (Impulse withstand voltage: (Impulse withstand voltage: (Impulse withstand voltage:
6 kV)
10 kV)
8 kV)
10 kV)
Applicable socket list
Model
○ (N.O.)
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Contact form
Applicable socket
○
○
○
○
○
○
G6B
1a
P6B-04P
P6B-06P
(2-coil latching
relay)
1a1b, 2a, 2b
P6B-26P
G6C
G6D
G7L
1a, 1a1b
1a
1a, 2a
P6D-04P
P7LF-06
P6C-06P
P6C-08P
(2-coil latching
relay)
○
○
Shape
3
PCB Relay Types
Introduction of Main Types
Signal Relay
We largely divide relays based on the maximum switching current value.
Signal Relay
Power Relay
Relays with less than 2 A maximum switching current value
Model
Relays larger than 2 A maximum switching current value
Features
Type Selection List (Best Selection)
Signal Relay
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
1c
2c
1A
2A
3A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
PCB terminal
Surface-mounting
Terminals
G5V-1
○
○
G5V-2
G6E
○
○
○
○
○
○
○
○
○
○
○
○
G6A
G6S
G6J-Y
G6K
G6K-RF
(-S,-T)
G6K-RF-V
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Power Relay
Item
Contact form
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
1a
1c
1a1b
2a
2b
3A
5A
7A
8A
10 A
15 A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
PCB terminal
Tab terminal
Item
Contact form
Switching
current
(Max value)
Latching
function
Enclosure
rating
Terminal
rating
2
G6K
G6K(U)-2F(P)-RF(S,-T)
G6K-2F-RF-V
Ultra-small low
profile relay
Low power
consumption
1 GHz/3 GHz range
Ultra-small high
frequency relay
8-GHz Band
High Frequency
Relay for Differential
Transmission
G6J-Y
Small general purpose
Ultra-small slim relay
relay
High density
High dielectric
application possible
strength, high current
Shape
Item
Contact form
G6S
1a
1c
1a1b
2a
2c
4A
5A
8A
10 A
12 A
15 A
16 A
20 A
25 A
30 A
1-coil latching relay
2-coil latching relay
Sealed
Flux protection
Enclosed
PCB terminal
Tab terminal
Screw terminal
Contact form
2c
2c
2c
2c
2c
Max. switching
current
2A
1A
1A
1A
1A
Coil power
consumption
Approx. 140 to 200
mW
Approx. 140 to 230
mW
Approx. 100 mW
Approx. 100 mW
Approx. 100 mW
Dielectric strength
(Between coil and
contacts)
2,000 VAC
(Impulse withstand
voltage: 2.5 kV)
1,500 VAC
(Impulse withstand
voltage: 2.5 kV)
1,500 VAC
(Impulse withstand
voltage: 2.5 kV)
750 VAC
AC350V
Power Relay
G6DN
○
○
G5NB
(-EL)
○
G5Q(-EL/EL2/-EL3)
○
○
○
G6D
G6B
G6RN
G6RL
G5LE
G5CA
G6C
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
G4W
G4A
G2RL
G5RL
○
○
○
○
○
○
○
○
○
○
○
○
G5RL
-U/-K
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ (N.C.)
○
○
○
G2RG
○
○ (N.O.)
○ (N.O.)
G6DN
G5NB(-EL)
G5Q(-EL/-EL2/-EL3)
G2RL
Small, slim power relay
with 1-pole 5 A switching
Small general purpose relay
with 1-pole switching at
7 A max
Small power relay
with 1-pole 10 A switching
Low profile power relay
with 1-pole 10 A/16 A
throw/2-pole 5 A switching
Contact form
1a
1a
1a, 1c
1a, 1c, 2a, 2c
Max. switching
current
5A
AC: 7 A, DC: 5 A (-EL)
3 A (standard type)
10 A
10 A/16 A (1a, 1c)
5 A (2a, 2c)
Approx. 110 mW
Approx. 200 mW
Approx. 200 mW
Approx. 400 mW
5 to 24 VDC: Approx. 400 mW
48 VDC: Approx. 430 mW
Features
Shape
○
○ (N.C.)
○
Model
○
○
○
○
○
○
○
○
○
G2R
G7L
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
G7L
-PV
G7L
-X
○
○
Coil power
consumption
Dielectric strength
(Between coil and
contacts)
3,000 VAC
4,000 VAC
4,000 VAC
5,000 VAC
(Impulse withstand voltage: (Impulse withstand voltage: (Impulse withstand voltage: (Impulse withstand voltage:
6 kV)
10 kV)
8 kV)
10 kV)
Applicable socket list
Model
○ (N.O.)
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Contact form
Applicable socket
○
○
○
○
○
○
G6B
1a
P6B-04P
P6B-06P
(2-coil latching
relay)
1a1b, 2a, 2b
P6B-26P
G6C
G6D
G7L
1a, 1a1b
1a
1a, 2a
P6D-04P
P7LF-06
P6C-06P
P6C-08P
(2-coil latching
relay)
○
○
Shape
3
Signal Relay Product Lineup INDEX
Model
G5V-1
Signal Relay Product Lineup INDEX
G5V-2
G6A
G6E
Model
G6J-Y
G6J-2FS-Y
Surface-mounting terminal (short)
G6J-2P-Y
PCB terminal
G6J-2FL-Y
Surface-mounting terminal (long)
Outer shape
Outer shape
Coil
Rated
load
―
―
1A
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
2A
2c
Crossbar twin
500,000 operations min.
at 125 VAC, 0.5 A
500,000 operations min.
at 30 VDC, 2 A
500,000 operations min.
at 125 VAC, 0.3 A
500,000 operations min.
at 30 VDC, 1 A
2A
5 VDC 1 mA
10 mVDC 10 μA
10 mVDC 10 μA
10 mVDC 10 μA
3 to 24 VDC
3 to 48 VDC
5 to 48 VDC
Approx. 150 mW
Standard type:
Approx. 500 to 580 mW
High sensitivity type:
Approx. 150 to 300 mW
3 to 48 VDC
Standard type:
Approx. 200 to 235 mW
Low-sensitivity Approx.400mW
High sensitivity type:
Approx. 150 mW
100,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
Approx. 200 to 400 mW
2-coil latching relay
―
●
●
1-coil latching relay
―
―
●
●
Other
―
―
―
Ultrasonically cleanable
Enclosed
―
―
―
―
Flux protection
―
―
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
●
●
●
●
●
●
●
―
―
―
―
―
UL, CSA
25 pcs/tube
Approx. 2 g
G5V-1
―
UL, CSA
25 pcs/tube
Approx. 5 g
G5V-2
―
UL, C-UL
25 pcs/tube
Approx. 3.5 g
G6A-274P
―
UL, CSA
25 pcs/tube
Approx. 2.7 g
G6E-134P-US
G6E-134PL-US
Between contacts of
different polarity
―
Between contacts of
the same polarity
400 VAC
―
Between set/reset coil
-40°C to 70°C (Standard type)
-40°C to 90°C (G5V-1-T90)
Terminal
Enclosure rating Functions
Ambient operating
temperature
2.54
5.08±0.1
(Unit: mm)
7.62
10.16±0.1
(1.07)
7.62
(1.3)
5.08 5.08
(1.3)
(1.2)
7.62
5.08 5.08
5.08
(1.65)
(1.2)
(BOTTOM VIEW)
(BOTTOM VIEW)
G5V-2
G6A-274P
G6E-134P-US
G6E-134PL-US
5
10
9
6
3 to 24 VDC
Approx. 140 to 230 mW
50,000,000 operations min.
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
750 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
―
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
-40°C to 85°C
―
1-coil latching relay
●
Other
―
Enclosed
―
Flux protection
―
●
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
―
―
●
―
UL, C-UL
50 pcs/tube
50 pcs/tube, 400 pcs/relay
Approx. 1.0 g
G6J-2FS-Y
Direction indicator
1
16
4
6
13 11
8
Direction indicator
1
9
(BOTTOM VIEW)
+
16
−
4
13
6
11
9
(BOTTOM VIEW)
(Take note of coil polarity)
1+
12
7.6
5.4
3.2
2.35
3.2
(1.5)
(1.25)
5.2
4.35
3.2
(Unit: mm)
0.8
(1.5)
0.8
(1.5)
−6
10
(BOTTOM VIEW)
(TOP VIEW)
(TOP VIEW)
G6J-2P-Y
G6J-2FS-Y
G6J-2FL-Y
Direction indicator
1
Direction indicator
8
7.6
5.4
3.2
8-ø0.85 hole
G6J-2FL-Y
7.62
(BOTTOM VIEW)
2
10 mVDC 10 μA
Between coil and
contacts
7.62
G5V-1
1
1A
PCB diagram
7.62
(1.2)
10.9 x 6 x 10
―
7.6
5.4
3.2
(1.19)
2.54
(BOTTOM VIEW)
(BOTTOM VIEW)
4
(1.2)
10.9 x 6 x 10
Ultra-small ultra-thin surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
G6J-2P-Y
5-ø1.0 hole
2.54
8-ø1 hole
2.54
10.9 x 6 x 9.3
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
(1.2)
Direction indicator
Terminal array diagram/
internal connection
diagram
-40°C to 70°C
7.62
(1.11)
2.54
(1.07)
-40°C to 70°C
2.54
(1.2)
2.54
―
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
―
250 VAC
8-ø1 hole
(1.11)
2.54
PCB diagram
2.54
6-ø1 hole
100,000,000 operations min.
1,500 VAC
(Impulse withstand voltage
2.5 kV FCC part 68 standard)
1,000 VAC
1,000 VAC
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Terminal
Between coil and
contacts
5,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
FCC-standard high-voltage type
15,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage: 1.5 kV)
750 VAC (Standard type)
500 VAC (High sensitivity type)
(Impulse withstand voltage: 1.5 kV)
―
-25°C to 65°C
(High sensitivity between -25
and 70°C)
―
Dielectric strength
Mechanical endurance
16 x 10 x 8
Small, high sensitivity
1-pole signal relay
1c
Crossbar twin
100,000 operations min.
at 125 VAC, 0.4 A
500,000 operations min.
at 30 VDC, 2 A
100,000 operations min.
at 125 VAC, 0.2 A
500,000 operations min.
at 30 VDC, 1 A
3A
Contact
Contact
Resistive
load
20.2 x 10.1 x 8.4
Coil
Contact form
Contact type
20.5 x 10.1 x 11.5
General purpose low-cost
2-pole signal relay
2c
Crossbar twin
100,000 operations min.
at 125 VAC, 0.5 A
100,000 operations min.
at 30 VDC, 2 A (Standard type)
Dielectric strength
Features
12.5 x 7.5 x 10
General purpose low-cost
1-pole signal relay
1c
Crossbar single
100,000 operations min.
at 125 VAC, 0.5 A
100,000 operations min.
at 24 VDC, 1 A
Enclosure rating Functions
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
7
(BOTTOM VIEW)
(Take note of coil polarity)
Terminal array diagram/
internal connection
diagram
8
2
3
Direction indicator
4
8
7
6
Direction indicator
5
8
+
−
−
−
+
+
7
6
5
(BOTTOM VIEW)
(Take note of coil polarity)
1
2
3
4
(TOP VIEW)
(Take note of coil polarity)
1
7
6
5
2
3
4
(TOP VIEW)
(Take note of coil polarity)
5
Signal Relay Product Lineup INDEX
Model
G5V-1
Signal Relay Product Lineup INDEX
G5V-2
G6A
G6E
Model
G6J-Y
G6J-2FS-Y
Surface-mounting terminal (short)
G6J-2P-Y
PCB terminal
G6J-2FL-Y
Surface-mounting terminal (long)
Outer shape
Outer shape
Coil
Rated
load
―
―
1A
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
2A
2c
Crossbar twin
500,000 operations min.
at 125 VAC, 0.5 A
500,000 operations min.
at 30 VDC, 2 A
500,000 operations min.
at 125 VAC, 0.3 A
500,000 operations min.
at 30 VDC, 1 A
2A
5 VDC 1 mA
10 mVDC 10 μA
10 mVDC 10 μA
10 mVDC 10 μA
3 to 24 VDC
3 to 48 VDC
5 to 48 VDC
Approx. 150 mW
Standard type:
Approx. 500 to 580 mW
High sensitivity type:
Approx. 150 to 300 mW
3 to 48 VDC
Standard type:
Approx. 200 to 235 mW
Low-sensitivity Approx.400mW
High sensitivity type:
Approx. 150 mW
100,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
Approx. 200 to 400 mW
2-coil latching relay
―
●
●
1-coil latching relay
―
―
●
●
Other
―
―
―
Ultrasonically cleanable
Enclosed
―
―
―
―
Flux protection
―
―
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
●
●
●
●
●
●
●
―
―
―
―
―
UL, CSA
25 pcs/tube
Approx. 2 g
G5V-1
―
UL, CSA
25 pcs/tube
Approx. 5 g
G5V-2
―
UL, C-UL
25 pcs/tube
Approx. 3.5 g
G6A-274P
―
UL, CSA
25 pcs/tube
Approx. 2.7 g
G6E-134P-US
G6E-134PL-US
Between contacts of
different polarity
―
Between contacts of
the same polarity
400 VAC
―
Between set/reset coil
-40°C to 70°C (Standard type)
-40°C to 90°C (G5V-1-T90)
Terminal
Enclosure rating Functions
Ambient operating
temperature
2.54
5.08±0.1
(Unit: mm)
7.62
10.16±0.1
(1.07)
7.62
(1.3)
5.08 5.08
(1.3)
(1.2)
7.62
5.08 5.08
5.08
(1.65)
(1.2)
(BOTTOM VIEW)
(BOTTOM VIEW)
G5V-2
G6A-274P
G6E-134P-US
G6E-134PL-US
5
10
9
6
3 to 24 VDC
Approx. 140 to 230 mW
50,000,000 operations min.
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
750 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
―
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
-40°C to 85°C
―
1-coil latching relay
●
Other
―
Enclosed
―
Flux protection
―
●
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
―
―
●
―
UL, C-UL
50 pcs/tube
50 pcs/tube, 400 pcs/relay
Approx. 1.0 g
G6J-2FS-Y
Direction indicator
1
16
4
6
13 11
8
Direction indicator
1
9
(BOTTOM VIEW)
+
16
−
4
13
6
11
9
(BOTTOM VIEW)
(Take note of coil polarity)
1+
12
7.6
5.4
3.2
2.35
3.2
(1.5)
(1.25)
5.2
4.35
3.2
(Unit: mm)
0.8
(1.5)
0.8
(1.5)
−6
10
(BOTTOM VIEW)
(TOP VIEW)
(TOP VIEW)
G6J-2P-Y
G6J-2FS-Y
G6J-2FL-Y
Direction indicator
1
Direction indicator
8
7.6
5.4
3.2
8-ø0.85 hole
G6J-2FL-Y
7.62
(BOTTOM VIEW)
2
10 mVDC 10 μA
Between coil and
contacts
7.62
G5V-1
1
1A
PCB diagram
7.62
(1.2)
10.9 x 6 x 10
―
7.6
5.4
3.2
(1.19)
2.54
(BOTTOM VIEW)
(BOTTOM VIEW)
4
(1.2)
10.9 x 6 x 10
Ultra-small ultra-thin surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
G6J-2P-Y
5-ø1.0 hole
2.54
8-ø1 hole
2.54
10.9 x 6 x 9.3
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
(1.2)
Direction indicator
Terminal array diagram/
internal connection
diagram
-40°C to 70°C
7.62
(1.11)
2.54
(1.07)
-40°C to 70°C
2.54
(1.2)
2.54
―
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
―
250 VAC
8-ø1 hole
(1.11)
2.54
PCB diagram
2.54
6-ø1 hole
100,000,000 operations min.
1,500 VAC
(Impulse withstand voltage
2.5 kV FCC part 68 standard)
1,000 VAC
1,000 VAC
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Terminal
Between coil and
contacts
5,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
FCC-standard high-voltage type
15,000,000 operations min.
1,000 VAC
(Impulse withstand voltage
1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage: 1.5 kV)
750 VAC (Standard type)
500 VAC (High sensitivity type)
(Impulse withstand voltage: 1.5 kV)
―
-25°C to 65°C
(High sensitivity between -25
and 70°C)
―
Dielectric strength
Mechanical endurance
16 x 10 x 8
Small, high sensitivity
1-pole signal relay
1c
Crossbar twin
100,000 operations min.
at 125 VAC, 0.4 A
500,000 operations min.
at 30 VDC, 2 A
100,000 operations min.
at 125 VAC, 0.2 A
500,000 operations min.
at 30 VDC, 1 A
3A
Contact
Contact
Resistive
load
20.2 x 10.1 x 8.4
Coil
Contact form
Contact type
20.5 x 10.1 x 11.5
General purpose low-cost
2-pole signal relay
2c
Crossbar twin
100,000 operations min.
at 125 VAC, 0.5 A
100,000 operations min.
at 30 VDC, 2 A (Standard type)
Dielectric strength
Features
12.5 x 7.5 x 10
General purpose low-cost
1-pole signal relay
1c
Crossbar single
100,000 operations min.
at 125 VAC, 0.5 A
100,000 operations min.
at 24 VDC, 1 A
Enclosure rating Functions
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
7
(BOTTOM VIEW)
(Take note of coil polarity)
Terminal array diagram/
internal connection
diagram
8
2
3
Direction indicator
4
8
7
6
Direction indicator
5
8
+
−
−
−
+
+
7
6
5
(BOTTOM VIEW)
(Take note of coil polarity)
1
2
3
4
(TOP VIEW)
(Take note of coil polarity)
1
7
6
5
2
3
4
(TOP VIEW)
(Take note of coil polarity)
5
Signal Relay Product Lineup INDEX
Model
Signal Relay Product Lineup INDEX
G6K
G6K-2F-Y
Outer L shape surface-mounting terminal
G6K-2P-Y
PCB terminal
Model
G6K-2G-Y
Inner L shape surface-mounting terminal
G6K(U)-2F-RF
G6K(U)-2(F/P)-RF(-S,-T)
G6K(U)-2F-RF-S
G6K(U)-2F-RF-T
10.6 x 7.2 x 5.7
11.0 x 7.2 x 5.7
G6K-2F-RF-V
G6K-2P-RF
Outer shape
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Outer shape
10.2 x 6.7 x 5.3
10.2 x 6.7 x 5.4
10 mVDC 10 μA
Approx. 100 mW
Contact
50,000,000 operations min.
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
750 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
―
●
―
Enclosed
―
Flux protection
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
Terminal
―
―
●
50 pcs/tube
3.2
Terminal Enclosure rating Functions
―
UL, CSA
50 pcs/tube, 900 pcs/relay
Approx. 0.7 g
G6K-2F-Y
8-ø0.85 hole
7.6
5.4
G6K-2G-Y
7.6
5.4
3.2
3.2
7.6
5.4
PCB diagram
1.8
5.08
(Unit: mm)
(0.71)
(1.2)
Insertion loss
0.2 dB max. at 1 GHz
Return loss
20.8 dB min. at 1 GHz
Rated
load
0.8
(1.2)
7
1.8
5.7
1
8
2
3
4
7
6
5
7
−
−
−
+
+
7
6
5
1
2
3
4
(TOP VIEW)
(Take note of coil polarity)
1
6
(TOP VIEW)
(Take note of coil polarity)
500 VAC
AC350V
―
1.1
2.54
1.35
4-1.15
7
2.1
1.8
0.8
7
12-ø0.85 hole
2.54
1.27
2.54
(9.2)
4.24
5
(TOP VIEW)
G6K-2F-RF-S
8
+
(0.89)
12.7
1
(BOTTOM VIEW)
G6K-2F-RF-T
Direction indicator
7
6
5
8
G6K-2P-RF
Direction indicator
7
6
5
1
3
4
1
G6K-2F-RF-V
Direction indicator
2
3
4
8
2
3
4
8
7
6
5
2
3
4
−
+
-
+
2
(TOP VIEW)
+
−
+
4
(0.3)
0.7
(TOP VIEW)
−
3
(2.45)
2.2 2.2
14-0.8
Direction indicator
6
10.16
8.89
7.62
6.35
5.08
3.81
5.08
7
10.8
1.35
1.8
1
−
2
40 pcs/tube
Approx.1.16g
G6K-2F-RF-V
G6K-2P-RF
7.6
(1.35)
G6K-2F-RF
1
30 pcs/tube
4.8
(1.35)
Terminal array diagram/
internal connection diagram
―
●
5.4
3.2
2.5
0.8
1.95
7
●
―
―
―
8.8
7.6
7.5
(TOP VIEW)
4
AC350V
4.8
8
3
750 VAC
5.4
3.2
1.2
1.6
Direction indicator
2
AC350V
2.5
5
100,000 operations min.
at 125 VAC, 0.3 A
100,000 operations min.
at 30 VDC, 1 A
1,000,000 operations
min. at 10 VDC, 10mA
100,000 operations min.
at 8 GHz, 1 W
300 pcs/tray, 300, 900 pcs/relay
Approx. 0.95 g
G6K-2F-RF-S
G6K-2F-RF-T
7.6
8
3.57 max. at 8GHz
●
5.4
3.2
+
(BOTTOM VIEW)
(Take note of coil polarity)
6
8
1.2 max. at 1 GHz
750 VAC
―
●
G6K-2F-RF
Direction indicator
5 dB max. at 8GHz
―
11.5
Direction indicator
20.8 dB min. at 1 GHz
●
0.8
(1.2)
(Unit: mm)
Single-ended:
4 dB max. at 8GHz
Differential transmission:
3 dB max. at 8GHz
AC350V
―
0.2 dB max. at 1 GHz
-40°C to 70°C
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
G6K-2G-Y
15 dB min. at 8 GHz
750 VAC
―
G6K-2F-Y
30 dB min. at 1 GHz
Approx. 100 mW
Flux protection
G6K-2P-Y
15 dB min. at 8 GHz
50,000,000 operations min.
Enclosed
PCB diagram
20 dB min. at 1 GHz
3 to 12 VDC
―
(TOP VIEW)
Series of PCB terminals
3 to 24 VDC
Other
(TOP VIEW)
11.9× 8.1× 7.4
High-speed Differential
Transmission
Signal Switching
8-GHz Band Miniature
High Frequency Relay
―
1A
1-coil latching relay
(BOTTOM VIEW)
13.6 x 7.2 x 5.5
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
100,000 operations min. at 1 GHz, 1 W
Resistive load
1.8
Terminal array diagram/
internal connection
diagram
20.8 dB min. at 1 GHz
15.6 dB min. at 3 GHz
1.2 max. at 1 GHz
1.4 max. at 3 GHz
2c
Crossbar twin
1.2 max. at 1 GHz
0.5
Direction indicator
0.2 dB max. at 1 GHz
0.6 dB max. at 3 GHz
Coil
●
G6K-2P-Y
30 dB min. at 1 GHz
Dielectric strength
―
Other
Isolation (different poles)
Inductive load
Max. switching current (A)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of the
same polarity
Between coil, contact,
and earth
Ambient operating
temperature
2-coil latching relay
-40°C to 70°C
1 coil latching relay
20 dB min. at 1 GHz
V.SWR
3 GHz range ultra-small
high frequency relay
50 Ω
20 dB min. at 1 GHz
18 dB min. at 3 GHz
30 dB min. at 1 GHz
25 dB min. at 3 GHz
Isolation (similar poles)
Contact form
Contact type
3 to 24 VDC
Coil
Dielectric strength
High frequency characteristics
1A
Between coil and
contacts
1 GHz range ultra-small
high frequency relay
(space-saving type)
Characteristic resistance
―
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
Enclosure rating Functions
10.2 x 6.7 x 5.6
Ultra-small low power consumption Ultra-thin low profile surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
Contact
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
1 GHz range ultra-small
high frequency relay
Features
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
11.0 x 7.2 x 5.7
7
6
5
1
(TOP VIEW)
(TOP VIEW)
(TOP VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity)
7
Signal Relay Product Lineup INDEX
Model
Signal Relay Product Lineup INDEX
G6K
G6K-2F-Y
Outer L shape surface-mounting terminal
G6K-2P-Y
PCB terminal
Model
G6K-2G-Y
Inner L shape surface-mounting terminal
G6K(U)-2F-RF
G6K(U)-2(F/P)-RF(-S,-T)
G6K(U)-2F-RF-S
G6K(U)-2F-RF-T
10.6 x 7.2 x 5.7
11.0 x 7.2 x 5.7
G6K-2F-RF-V
G6K-2P-RF
Outer shape
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Outer shape
10.2 x 6.7 x 5.3
10.2 x 6.7 x 5.4
10 mVDC 10 μA
Approx. 100 mW
Contact
50,000,000 operations min.
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
750 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
―
●
―
Enclosed
―
Flux protection
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
Terminal
―
―
●
50 pcs/tube
3.2
Terminal Enclosure rating Functions
―
UL, CSA
50 pcs/tube, 900 pcs/relay
Approx. 0.7 g
G6K-2F-Y
8-ø0.85 hole
7.6
5.4
G6K-2G-Y
7.6
5.4
3.2
3.2
7.6
5.4
PCB diagram
1.8
5.08
(Unit: mm)
(0.71)
(1.2)
Insertion loss
0.2 dB max. at 1 GHz
Return loss
20.8 dB min. at 1 GHz
Rated
load
0.8
(1.2)
7
1.8
5.7
1
8
2
3
4
7
6
5
7
−
−
−
+
+
7
6
5
1
2
3
4
(TOP VIEW)
(Take note of coil polarity)
1
6
(TOP VIEW)
(Take note of coil polarity)
500 VAC
AC350V
―
1.1
2.54
1.35
4-1.15
7
2.1
1.8
0.8
7
12-ø0.85 hole
2.54
1.27
2.54
(9.2)
4.24
5
(TOP VIEW)
G6K-2F-RF-S
8
+
(0.89)
12.7
1
(BOTTOM VIEW)
G6K-2F-RF-T
Direction indicator
7
6
5
8
G6K-2P-RF
Direction indicator
7
6
5
1
3
4
1
G6K-2F-RF-V
Direction indicator
2
3
4
8
2
3
4
8
7
6
5
2
3
4
−
+
-
+
2
(TOP VIEW)
+
−
+
4
(0.3)
0.7
(TOP VIEW)
−
3
(2.45)
2.2 2.2
14-0.8
Direction indicator
6
10.16
8.89
7.62
6.35
5.08
3.81
5.08
7
10.8
1.35
1.8
1
−
2
40 pcs/tube
Approx.1.16g
G6K-2F-RF-V
G6K-2P-RF
7.6
(1.35)
G6K-2F-RF
1
30 pcs/tube
4.8
(1.35)
Terminal array diagram/
internal connection diagram
―
●
5.4
3.2
2.5
0.8
1.95
7
●
―
―
―
8.8
7.6
7.5
(TOP VIEW)
4
AC350V
4.8
8
3
750 VAC
5.4
3.2
1.2
1.6
Direction indicator
2
AC350V
2.5
5
100,000 operations min.
at 125 VAC, 0.3 A
100,000 operations min.
at 30 VDC, 1 A
1,000,000 operations
min. at 10 VDC, 10mA
100,000 operations min.
at 8 GHz, 1 W
300 pcs/tray, 300, 900 pcs/relay
Approx. 0.95 g
G6K-2F-RF-S
G6K-2F-RF-T
7.6
8
3.57 max. at 8GHz
●
5.4
3.2
+
(BOTTOM VIEW)
(Take note of coil polarity)
6
8
1.2 max. at 1 GHz
750 VAC
―
●
G6K-2F-RF
Direction indicator
5 dB max. at 8GHz
―
11.5
Direction indicator
20.8 dB min. at 1 GHz
●
0.8
(1.2)
(Unit: mm)
Single-ended:
4 dB max. at 8GHz
Differential transmission:
3 dB max. at 8GHz
AC350V
―
0.2 dB max. at 1 GHz
-40°C to 70°C
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
G6K-2G-Y
15 dB min. at 8 GHz
750 VAC
―
G6K-2F-Y
30 dB min. at 1 GHz
Approx. 100 mW
Flux protection
G6K-2P-Y
15 dB min. at 8 GHz
50,000,000 operations min.
Enclosed
PCB diagram
20 dB min. at 1 GHz
3 to 12 VDC
―
(TOP VIEW)
Series of PCB terminals
3 to 24 VDC
Other
(TOP VIEW)
11.9× 8.1× 7.4
High-speed Differential
Transmission
Signal Switching
8-GHz Band Miniature
High Frequency Relay
―
1A
1-coil latching relay
(BOTTOM VIEW)
13.6 x 7.2 x 5.5
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
100,000 operations min. at 1 GHz, 1 W
Resistive load
1.8
Terminal array diagram/
internal connection
diagram
20.8 dB min. at 1 GHz
15.6 dB min. at 3 GHz
1.2 max. at 1 GHz
1.4 max. at 3 GHz
2c
Crossbar twin
1.2 max. at 1 GHz
0.5
Direction indicator
0.2 dB max. at 1 GHz
0.6 dB max. at 3 GHz
Coil
●
G6K-2P-Y
30 dB min. at 1 GHz
Dielectric strength
―
Other
Isolation (different poles)
Inductive load
Max. switching current (A)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of the
same polarity
Between coil, contact,
and earth
Ambient operating
temperature
2-coil latching relay
-40°C to 70°C
1 coil latching relay
20 dB min. at 1 GHz
V.SWR
3 GHz range ultra-small
high frequency relay
50 Ω
20 dB min. at 1 GHz
18 dB min. at 3 GHz
30 dB min. at 1 GHz
25 dB min. at 3 GHz
Isolation (similar poles)
Contact form
Contact type
3 to 24 VDC
Coil
Dielectric strength
High frequency characteristics
1A
Between coil and
contacts
1 GHz range ultra-small
high frequency relay
(space-saving type)
Characteristic resistance
―
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
Enclosure rating Functions
10.2 x 6.7 x 5.6
Ultra-small low power consumption Ultra-thin low profile surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.3 A
100,000 operations min. at 30 VDC, 1 A
Contact
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
1 GHz range ultra-small
high frequency relay
Features
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
11.0 x 7.2 x 5.7
7
6
5
1
(TOP VIEW)
(TOP VIEW)
(TOP VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity)
7
Power Relay Product Lineup INDEX
Signal Relay Product Lineup INDEX
Model
G6S
G6S-2F
Outer L shape surface-mounting terminal
G6S-2
PCB terminal
Model
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSφ=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
15 x 7.5 x 9.4
15 x 7.5 x 9.4
Contact
Approx. 140 to 200 mW
Dielectric strength
-40°C to 85°C
●
Flux protection
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
●
―
―
●
―
UL, CSA, EN/IEC (BSI certification -Y type)
50 pcs/tube, 400 pcs/relay
Approx. 2 g
G6S-2F
G6S-2F-Y
50 pcs/tube
G6S-2
G6S-2-Y
2.54
Enclosure rating Functions
―
Between
set/reset coil
Ambient operating
temperature
2-coil latching relay
8-ø1 hole
5.08
2.54
2.54
2.54
G6S-2G
G6S-2G-Y
5.08
2.54
2.54
2.2
5.08±0.1
5.08
(1.05)
8
2.2
2.54
1
1
2.54
(TOP VIEW)
(TOP VIEW)
G6S-2
G6S-2-Y
G6S-2F
G6S-2F-Y
G6S-2G
G6S-2G-Y
1
Terminal array diagram/
internal connection
diagram
12
3
4
5
12
10 9
8
12
10 9
+
−
−
−
+
+
10 9
8
(BOTTOM VIEW)
(Take note of coil polarity)
1
3
4
5
(TOP VIEW)
(Take note of coil polarity)
5 VDC 10 mA
5 to 24 VDC
1
3
4
750 VAC
-40°C to 70°C
-40°C to 85°C
―
―
―
―
―
Enclosed
―
―
●
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
●
●
●
●
●
―
―
―
―
UL, C-UL, EN/IEC (VDE certification)
25 pcs/tube
Approx. 3 g
G6DN-1A
―
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 4 g
G5NB-1A/G5NB-1A4-EL-HA
6.1
7.62 ±0.1
(1.05)
4-ø1.1 hole
2.54
±0.1
±0.1
7
4-ø1.1
4.7
(Unit: mm)
8
Terminal array diagram/
internal connection diagram
11.5
(1.15)
(1.32)
(TOP VIEW)
(Take note of coil polarity)
―
―
PCB diagram
5
Approx. 200 mW
5,000,000 operations min.
4,000 VAC
(Impulse withstand voltage: 10 kV)
―
-40°C to 90°C
Direction indicator
Direction indicator
―
AC: 7 A, DC: 5 A
Flux protection
(BOTTOM VIEW)
Direction indicator
―
3A
―
7.62 ±0.1
(1.11)
―
1-coil latching relay
PCB diagram
(Unit: mm)
200,000 operations min. at 250 VAC, 5 A
50,000 operations min. at 250 VAC, 7 A
100,000 operations min. at 30 VDC, 5 A
200,000 operations min. at 125 VAC, 3 A
200,000 operations min. at 30 VDC, 3 A
Other
Terminal
―
Enclosed
Terminal
Other
1a
Single
Coil
100,000,000 operations min.
2,000 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
500 VAC
●
Small, slim power relay
with 1-pole 5 A switching
Contact
Rated load
3 to 24 VDC
Between contacts of
different polarity
20.5 x 7.2 x 15.3
Small power relay with 1-pole 7 A
switching
and ignition resistance internationalstandard compatibility
1a
Crossbar twin
100,000 operations min. at 250 VAC, 3 A (Standard)
100,000 operations min. at 30 VDC, 3 A (Standard)
80,000 operations min. at 250 VAC, 5 A (Standard)
Resistive load
80,000 operations min. at 30 VDC, 5 A (Standard)
100,000 operations min. at 250 VAC, 5 A (High durability)
100,000 operations min. at 30 VDC, 5 A (High durability)
100,000 operations min. at 250 VAC, 2 A (Standard)
Inductive load
100,000 operations min. at 30 VDC, 2 A (Standard)
COSø=0.4
200,000 operations min. at 250 VAC, 2 A (High durability)
L/R=7 ms
200,000 operations min. at 30 VDC, 2 A (High durability)
Capacitive load
―
Max. switching current (A)
5A
Failure rate (mA)
0.1 VDC 0.1 mA
P level (reference value)
Rated voltage
4.5 to 24 VDC
Rated power
Approx. 110 mW
consumption
Mechanical endurance
20,000,000 operations min.
Between coil and
3,000 VAC
contacts
(Impulse withstand voltage: 6 kV)
Between contacts of
―
different polarity
Between contacts of the
750 VAC
same polarity
10 mVDC 10 μA
Between coil and
contacts
20.5 x 7.2 x 15.3
1-pole 3 A switching relay with impulse
withstand voltage of 10 kV
And EN61010 strengthened insulation
Contact form
Contact type
2A
Coil
Dielectric strength
Features
―
1-coil latching relay
8
-EL
20.0 x 5.08 x 12.5
15 x 7.5 x 9.4
Small general purpose high dielectric strength, high current surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.5 A
100,000 operations min. at 30 VDC, 2 A
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
G5NB
Standard type
Outer shape
Outer shape
Enclosure rating Functions
G6DN
G6S-2G
Inner L shape surface-mounting terminal
1 2
(1.28)
(BOTTOM VIEW)
(BOTTOM VIEW)
G6DN-1A
G5NB-1A/G5NB-1A4-EL-HA
5
8
1
2
3
4
(BOTTOM VIEW)
(BOTTOM VIEW)
9
Power Relay Product Lineup INDEX
Signal Relay Product Lineup INDEX
Model
G6S
G6S-2F
Outer L shape surface-mounting terminal
G6S-2
PCB terminal
Model
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Features
Contact form
Contact type
Resistive
load
Rated
Inductive
load
load
COSφ=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level
(reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
15 x 7.5 x 9.4
15 x 7.5 x 9.4
Contact
Approx. 140 to 200 mW
Dielectric strength
-40°C to 85°C
●
Flux protection
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Approved standards
Minimum packing unit
Weight
●
●
―
―
●
―
UL, CSA, EN/IEC (BSI certification -Y type)
50 pcs/tube, 400 pcs/relay
Approx. 2 g
G6S-2F
G6S-2F-Y
50 pcs/tube
G6S-2
G6S-2-Y
2.54
Enclosure rating Functions
―
Between
set/reset coil
Ambient operating
temperature
2-coil latching relay
8-ø1 hole
5.08
2.54
2.54
2.54
G6S-2G
G6S-2G-Y
5.08
2.54
2.54
2.2
5.08±0.1
5.08
(1.05)
8
2.2
2.54
1
1
2.54
(TOP VIEW)
(TOP VIEW)
G6S-2
G6S-2-Y
G6S-2F
G6S-2F-Y
G6S-2G
G6S-2G-Y
1
Terminal array diagram/
internal connection
diagram
12
3
4
5
12
10 9
8
12
10 9
+
−
−
−
+
+
10 9
8
(BOTTOM VIEW)
(Take note of coil polarity)
1
3
4
5
(TOP VIEW)
(Take note of coil polarity)
5 VDC 10 mA
5 to 24 VDC
1
3
4
750 VAC
-40°C to 70°C
-40°C to 85°C
―
―
―
―
―
Enclosed
―
―
●
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
●
●
●
●
●
―
―
―
―
UL, C-UL, EN/IEC (VDE certification)
25 pcs/tube
Approx. 3 g
G6DN-1A
―
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 4 g
G5NB-1A/G5NB-1A4-EL-HA
6.1
7.62 ±0.1
(1.05)
4-ø1.1 hole
2.54
±0.1
±0.1
7
4-ø1.1
4.7
(Unit: mm)
8
Terminal array diagram/
internal connection diagram
11.5
(1.15)
(1.32)
(TOP VIEW)
(Take note of coil polarity)
―
―
PCB diagram
5
Approx. 200 mW
5,000,000 operations min.
4,000 VAC
(Impulse withstand voltage: 10 kV)
―
-40°C to 90°C
Direction indicator
Direction indicator
―
AC: 7 A, DC: 5 A
Flux protection
(BOTTOM VIEW)
Direction indicator
―
3A
―
7.62 ±0.1
(1.11)
―
1-coil latching relay
PCB diagram
(Unit: mm)
200,000 operations min. at 250 VAC, 5 A
50,000 operations min. at 250 VAC, 7 A
100,000 operations min. at 30 VDC, 5 A
200,000 operations min. at 125 VAC, 3 A
200,000 operations min. at 30 VDC, 3 A
Other
Terminal
―
Enclosed
Terminal
Other
1a
Single
Coil
100,000,000 operations min.
2,000 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,500 VAC
(Impulse withstand voltage 2.5 kV Telcordia standard)
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
1,000 VAC
(Impulse withstand voltage 1.5 kV FCC part 68 standard)
500 VAC
●
Small, slim power relay
with 1-pole 5 A switching
Contact
Rated load
3 to 24 VDC
Between contacts of
different polarity
20.5 x 7.2 x 15.3
Small power relay with 1-pole 7 A
switching
and ignition resistance internationalstandard compatibility
1a
Crossbar twin
100,000 operations min. at 250 VAC, 3 A (Standard)
100,000 operations min. at 30 VDC, 3 A (Standard)
80,000 operations min. at 250 VAC, 5 A (Standard)
Resistive load
80,000 operations min. at 30 VDC, 5 A (Standard)
100,000 operations min. at 250 VAC, 5 A (High durability)
100,000 operations min. at 30 VDC, 5 A (High durability)
100,000 operations min. at 250 VAC, 2 A (Standard)
Inductive load
100,000 operations min. at 30 VDC, 2 A (Standard)
COSø=0.4
200,000 operations min. at 250 VAC, 2 A (High durability)
L/R=7 ms
200,000 operations min. at 30 VDC, 2 A (High durability)
Capacitive load
―
Max. switching current (A)
5A
Failure rate (mA)
0.1 VDC 0.1 mA
P level (reference value)
Rated voltage
4.5 to 24 VDC
Rated power
Approx. 110 mW
consumption
Mechanical endurance
20,000,000 operations min.
Between coil and
3,000 VAC
contacts
(Impulse withstand voltage: 6 kV)
Between contacts of
―
different polarity
Between contacts of the
750 VAC
same polarity
10 mVDC 10 μA
Between coil and
contacts
20.5 x 7.2 x 15.3
1-pole 3 A switching relay with impulse
withstand voltage of 10 kV
And EN61010 strengthened insulation
Contact form
Contact type
2A
Coil
Dielectric strength
Features
―
1-coil latching relay
8
-EL
20.0 x 5.08 x 12.5
15 x 7.5 x 9.4
Small general purpose high dielectric strength, high current surface-mounting 2-pole signal relay
2c
Crossbar twin
100,000 operations min. at 125 VAC, 0.5 A
100,000 operations min. at 30 VDC, 2 A
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
G5NB
Standard type
Outer shape
Outer shape
Enclosure rating Functions
G6DN
G6S-2G
Inner L shape surface-mounting terminal
1 2
(1.28)
(BOTTOM VIEW)
(BOTTOM VIEW)
G6DN-1A
G5NB-1A/G5NB-1A4-EL-HA
5
8
1
2
3
4
(BOTTOM VIEW)
(BOTTOM VIEW)
9
Power Relay Product Lineup INDEX
Model
Power Relay Product Lineup INDEX
G5Q
-EL
Standard type
Model
-EL2
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Features
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
Small power relay with 1-pole 10 A switching
10 A (250 VAC) high switching
capacity with over 100,000
operations and long operating
life, with ignition resistance
international-standard
compatibility
Switching at 40 A inrush
current through inrushcurrent resistance, with
ignition resistance
international-standard
compatibility
1a
30 A inrush current and
3 A breaking current
motor load switching,
with ignition resistance
international-standard
compatibility
Contact form
Contact type
1a
100,000 operations min.
at 250 VAC, 10 A
―
―
―
―
―
Motor load 250 VAC,
Inrush: 30 A/0.5 s,
Breaking: 3 A cosø=0.5,
300,000 operations min.
Capacitive load
―
―
250 VAC,
Inrush: 40 A/100 μs,
Breaking: 1 A,
100,000 operations min.
―
5 VDC 10 mA
Coil
5 to 24 VDC
Approx. 200 mW
Approx. 400 mW
10,000,000 operations min.
Dielectric strength
4,000 VAC (Impulse withstand voltage: 8 kV)
Standard type
20 x 10 x 10
20.2 x 10 x 12.5
2-pole
Standard type
High reliability type
1,000 VAC
―
-40°C to 85°C
―
1-coil latching relay
―
Other
―
―
Enclosed
●
●
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
●
―
●
●
●
Terminal
Flux protection
―
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 6.5 g
G5Q-1A-EL-HA-VH/G5Q-1A4-EL2-HA/
G5Q-1A4-EL3-HA
G5Q-1
G5Q-14
1.3
4-ø .1
±0
(1.18)
(1.19)
1.3
5-ø .1
±0
(1.18)
(1.19)
7.62±0.1
7.62±0.1
Between coil and
contacts
10.16±0.1
(BOTTOM VIEW)
(BOTTOM VIEW)
G5Q-1A
G5Q-1A4
G5Q-1
G5Q-14
G5Q-1A-EL-HA-VH/G5Q-1A4-EL2-HA/
G5Q-1A4-EL3-HA
2
3
5
(BOTTOM VIEW)
1
5
2c
Crossbar single
100,000 operations min.
at 250 VAC, 5 A
100,000 operations min.
at 30 VDC, 5 A
100,000 operations min.
at 250 VAC, 8 A
100,000 operations min.
at 30 VDC, 8 A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
100,000 operations min.
at 250 VAC, 5 A
100,000 operations min.
at 30 VDC, 5 A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
5A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
8A
100,000 operations min.
at 250 VAC, 0.5 A
100,000 operations min.
at 30 VDC, 0.5 A
2A
100,000 operations min.
at 250 VAC, 1.5 A
100,000 operations min.
at 30 VDC, 1.5 A
5A
5 VDC 10 mA
5 VDC 10 mA
DC1V 1mA
5 VDC 10 mA
5 to 24 VDC
Approx. 200 mW
20,000,000 operations
min.
5 to 24 VDC
Approx. 200 mW
3 to 12 VDC
Approx. 100 mW
5 to 24 VDC
Approx. 300 mW
3,000 VAC
(Impulse withstand
voltage: 6 kV)
50,000,000 operations min.
Single stable type: 3,000 VAC (impulse withstand
voltage 6 kV)
Latching type: 2,000 VAC (impulse withstand voltage
4.5 kV)
250 VAC
1-coil latching relay
―
●
Other
―
Enclosed
―
Flux protection
―
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
―
2,000 VAC
750 VAC
1,000 VAC
―
-25°C to 70°C
●
―
―
―
Ultrasonically cleanable
Ultrasonically cleanable
―
―
●
●
―
―
―
UL, CSA, EN/IEC (TÜV
certification)
25 pcs/tube
Approx. 3 g
G6D-1A-ASI(-AP)
PCB diagram
● (G6B-1177P-ND)
UL, CSA, EN/IEC (TÜV
certification)
100 pcs/tray
Approx. 3.5 g
Approx. 4.5 g
G6B-1184P-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
―
UL, CSA, EN/IEC (TÜV certification)
100 pcs/tray
Approx. 3.5 g
G6B-1114P-US
20 pcs/tube
Approx. 4.6 g
G6B-1174P-US
2.54
2.54
4-ø1.1 hole
4-ø1.1 hole
2.54
2.54
(1.2)
(1.2)
2.54
―
●
●
―
―
―
4-ø1.1
(0.71)
(Unit: mm)
AC3,000V
―
2.54
Single stable type: 3,000
VAC (impulse withstand
voltage 6 kV)
Latching type: 2,000 VAC
(impulse withstand
voltage 4.5 kV)
2.54
(1.2)
2.54
5.08
(1.13)
10.16
2
3
4
(BOTTOM VIEW)
1
2
3
5
(BOTTOM VIEW)
6-ø1.1 hole
2.54
4-ø1.1 hole
2.54
7.62
5.08
10.16
10.16
7.62
7.62
10.16
(1.2)
(1.1)
7.62
(1.7)
(1.1)
(1.11)
10.16
7.62
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(BOTTOM VIEW)
G6D-1A-ASI(-AP)
G6B-1114P-US
G6B-1174P-US
G6B-1184P-US
G6B-2114P-US
+
8
7.62
±0.1
10.16±0.1
(BOTTOM VIEW)
1
1a
Single
1
−
2.54
5.08 ±0.1
±0.1
7.62
±0.1
10.16±0.1
(1.18)
5A
Small 5 A (8 A) 1a contact power relay
―
-25°C to 70°C
―
1.3
4-ø .1
±0
(1.19)
―
20 x 11 x 11
Small 5 A 1a1b, 2a, 2b
contact
power relay
1a1b, 2a, 2b
Single
7.62±0.1
(Unit: mm)
Terminal array diagram/
internal connection
diagram
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power consumption
―
G5Q-1A
G5Q-1A4
PCB diagram
Rated
load
1a
Single
70,000 operations min.
at 250 VAC, 5 A
70,000 operations min.
at 30 VDC, 5 A
300,000 operations min.
at 250 VAC, 2 A
300,000 operations min.
at 30 VDC, 2 A
20 x 10 x 10
High reliability by adopting
Single crossbar contact
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating temperature
2-coil latching relay
Enclosure rating Functions
―
Resistive
load
Mechanical endurance
Dielectric strength
10 A
Contact
200,000 operations min.
at 125 VAC 3 A (N.C.)
100,000 operations min.
at 250 VAC 3 A (N.C.)
100,000 operations min.
at 30 VDC 3 A (N.C.)
Inductive load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between
set/reset coil
Ambient operating
temperature
2-coil latching relay
Enclosure rating Functions
Contact form
Contact type
Coil
50,000 operations min. at
125 VAC 10 A (N.O.)
200,000 operations min.
at 125 VAC 3 A (N.O.)
50,000 operations min. at
250 VAC 5 A (N.O.)
100,000 operations min.
at 250 VAC 3 A (N.O.)
100,000 operations min.
at 30 VDC 5 A (N.O.)
17.5 x 6.5 x 12.5
Small 5 A 1-pole power
relay
Features
Terminal
Contact
Rated load
1c
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Single
Resistive load
10
G6B
1-pole
High capacity type
Outer shape
Outer shape
G6D
-EL3
3
4
6
5
G6B-2214P-US
Terminal array diagram/
internal connection
diagram
5
1
13
7
1 −
6
+
3
4
1 −
6
+
3
4
1 −
6
+
3
4
1
−
+
8
3
4
6
5
G6B-2014P-US
1
−
+
8
3
4
6
5
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(BOTTOM VIEW)
(Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity)
11
Power Relay Product Lineup INDEX
Model
Power Relay Product Lineup INDEX
G5Q
-EL
Standard type
Model
-EL2
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Features
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
20.3 x 10.3 x 15.8
Small power relay with 1-pole 10 A switching
10 A (250 VAC) high switching
capacity with over 100,000
operations and long operating
life, with ignition resistance
international-standard
compatibility
Switching at 40 A inrush
current through inrushcurrent resistance, with
ignition resistance
international-standard
compatibility
1a
30 A inrush current and
3 A breaking current
motor load switching,
with ignition resistance
international-standard
compatibility
Contact form
Contact type
1a
100,000 operations min.
at 250 VAC, 10 A
―
―
―
―
―
Motor load 250 VAC,
Inrush: 30 A/0.5 s,
Breaking: 3 A cosø=0.5,
300,000 operations min.
Capacitive load
―
―
250 VAC,
Inrush: 40 A/100 μs,
Breaking: 1 A,
100,000 operations min.
―
5 VDC 10 mA
Coil
5 to 24 VDC
Approx. 200 mW
Approx. 400 mW
10,000,000 operations min.
Dielectric strength
4,000 VAC (Impulse withstand voltage: 8 kV)
Standard type
20 x 10 x 10
20.2 x 10 x 12.5
2-pole
Standard type
High reliability type
1,000 VAC
―
-40°C to 85°C
―
1-coil latching relay
―
Other
―
―
Enclosed
●
●
―
―
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
●
―
●
●
●
Terminal
Flux protection
―
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 6.5 g
G5Q-1A-EL-HA-VH/G5Q-1A4-EL2-HA/
G5Q-1A4-EL3-HA
G5Q-1
G5Q-14
1.3
4-ø .1
±0
(1.18)
(1.19)
1.3
5-ø .1
±0
(1.18)
(1.19)
7.62±0.1
7.62±0.1
Between coil and
contacts
10.16±0.1
(BOTTOM VIEW)
(BOTTOM VIEW)
G5Q-1A
G5Q-1A4
G5Q-1
G5Q-14
G5Q-1A-EL-HA-VH/G5Q-1A4-EL2-HA/
G5Q-1A4-EL3-HA
2
3
5
(BOTTOM VIEW)
1
5
2c
Crossbar single
100,000 operations min.
at 250 VAC, 5 A
100,000 operations min.
at 30 VDC, 5 A
100,000 operations min.
at 250 VAC, 8 A
100,000 operations min.
at 30 VDC, 8 A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
100,000 operations min.
at 250 VAC, 5 A
100,000 operations min.
at 30 VDC, 5 A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
5A
100,000 operations min.
at 250 VAC, 2 A
100,000 operations min.
at 30 VDC, 2 A
8A
100,000 operations min.
at 250 VAC, 0.5 A
100,000 operations min.
at 30 VDC, 0.5 A
2A
100,000 operations min.
at 250 VAC, 1.5 A
100,000 operations min.
at 30 VDC, 1.5 A
5A
5 VDC 10 mA
5 VDC 10 mA
DC1V 1mA
5 VDC 10 mA
5 to 24 VDC
Approx. 200 mW
20,000,000 operations
min.
5 to 24 VDC
Approx. 200 mW
3 to 12 VDC
Approx. 100 mW
5 to 24 VDC
Approx. 300 mW
3,000 VAC
(Impulse withstand
voltage: 6 kV)
50,000,000 operations min.
Single stable type: 3,000 VAC (impulse withstand
voltage 6 kV)
Latching type: 2,000 VAC (impulse withstand voltage
4.5 kV)
250 VAC
1-coil latching relay
―
●
Other
―
Enclosed
―
Flux protection
―
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
―
2,000 VAC
750 VAC
1,000 VAC
―
-25°C to 70°C
●
―
―
―
Ultrasonically cleanable
Ultrasonically cleanable
―
―
●
●
―
―
―
UL, CSA, EN/IEC (TÜV
certification)
25 pcs/tube
Approx. 3 g
G6D-1A-ASI(-AP)
PCB diagram
● (G6B-1177P-ND)
UL, CSA, EN/IEC (TÜV
certification)
100 pcs/tray
Approx. 3.5 g
Approx. 4.5 g
G6B-1184P-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
―
UL, CSA, EN/IEC (TÜV certification)
100 pcs/tray
Approx. 3.5 g
G6B-1114P-US
20 pcs/tube
Approx. 4.6 g
G6B-1174P-US
2.54
2.54
4-ø1.1 hole
4-ø1.1 hole
2.54
2.54
(1.2)
(1.2)
2.54
―
●
●
―
―
―
4-ø1.1
(0.71)
(Unit: mm)
AC3,000V
―
2.54
Single stable type: 3,000
VAC (impulse withstand
voltage 6 kV)
Latching type: 2,000 VAC
(impulse withstand
voltage 4.5 kV)
2.54
(1.2)
2.54
5.08
(1.13)
10.16
2
3
4
(BOTTOM VIEW)
1
2
3
5
(BOTTOM VIEW)
6-ø1.1 hole
2.54
4-ø1.1 hole
2.54
7.62
5.08
10.16
10.16
7.62
7.62
10.16
(1.2)
(1.1)
7.62
(1.7)
(1.1)
(1.11)
10.16
7.62
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(BOTTOM VIEW)
G6D-1A-ASI(-AP)
G6B-1114P-US
G6B-1174P-US
G6B-1184P-US
G6B-2114P-US
+
8
7.62
±0.1
10.16±0.1
(BOTTOM VIEW)
1
1a
Single
1
−
2.54
5.08 ±0.1
±0.1
7.62
±0.1
10.16±0.1
(1.18)
5A
Small 5 A (8 A) 1a contact power relay
―
-25°C to 70°C
―
1.3
4-ø .1
±0
(1.19)
―
20 x 11 x 11
Small 5 A 1a1b, 2a, 2b
contact
power relay
1a1b, 2a, 2b
Single
7.62±0.1
(Unit: mm)
Terminal array diagram/
internal connection
diagram
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power consumption
―
G5Q-1A
G5Q-1A4
PCB diagram
Rated
load
1a
Single
70,000 operations min.
at 250 VAC, 5 A
70,000 operations min.
at 30 VDC, 5 A
300,000 operations min.
at 250 VAC, 2 A
300,000 operations min.
at 30 VDC, 2 A
20 x 10 x 10
High reliability by adopting
Single crossbar contact
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating temperature
2-coil latching relay
Enclosure rating Functions
―
Resistive
load
Mechanical endurance
Dielectric strength
10 A
Contact
200,000 operations min.
at 125 VAC 3 A (N.C.)
100,000 operations min.
at 250 VAC 3 A (N.C.)
100,000 operations min.
at 30 VDC 3 A (N.C.)
Inductive load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between
set/reset coil
Ambient operating
temperature
2-coil latching relay
Enclosure rating Functions
Contact form
Contact type
Coil
50,000 operations min. at
125 VAC 10 A (N.O.)
200,000 operations min.
at 125 VAC 3 A (N.O.)
50,000 operations min. at
250 VAC 5 A (N.O.)
100,000 operations min.
at 250 VAC 3 A (N.O.)
100,000 operations min.
at 30 VDC 5 A (N.O.)
17.5 x 6.5 x 12.5
Small 5 A 1-pole power
relay
Features
Terminal
Contact
Rated load
1c
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Single
Resistive load
10
G6B
1-pole
High capacity type
Outer shape
Outer shape
G6D
-EL3
3
4
6
5
G6B-2214P-US
Terminal array diagram/
internal connection
diagram
5
1
13
7
1 −
6
+
3
4
1 −
6
+
3
4
1 −
6
+
3
4
1
−
+
8
3
4
6
5
G6B-2014P-US
1
−
+
8
3
4
6
5
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW)
(BOTTOM VIEW)
(Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity) (Take note of coil polarity)
11
Power Relay Product Lineup INDEX
Model
G6RN
Power Relay Product Lineup INDEX
G6RL
G5LE
G5CA
Model
Standard type
Outer shape
Terminal
Enclosure rating Functions
Dielectric strength
Coil
Inductive
load
―
―
COSø=0.4
L/R=7 ms
Max. switching current (A)
8A
10 A
Failure rate (mA)
5 VDC 10 mA
5 VDC 10 mA
P level (reference value)
Rated voltage
5 to 24 VDC
3 to 48 VDC
Rated power
Approx. 220 mW
Approx. 220 to 240 mW
consumption
Mechanical endurance
10,000,000 operations min. 10,000,000 operations min.
Between coil and
4,000 VAC (Impulse
5,000 VAC (Impulse
contacts
withstand voltage: 10 kV) withstand voltage: 10 kV)
Between contacts of
―
―
different polarity
Between contacts of
1,000 VAC
1,000 VAC
the same polarity
Between set/reset coil
―
―
Ambient operating
-40°C to 85°C
-40°C to 85°C
temperature
2-coil latching relay
―
―
1-coil latching relay
―
―
Other
―
―
Enclosed
―
―
Flux protection
―
●
Sealed
●
●
PCB terminal
●
●
Surface-mounting Terminals
―
―
Tab terminal
―
―
Screw terminal
―
―
UL, CSA,
UL, C-UL,
Approved standards
EN/IEC (VDE certification) EN/IEC (VDE certification)
Minimum packing unit
20 pcs/tube
100 pcs/tray
Weight
Approx. 9 g
Approx. 7.8 g
G6RN-1A
G6RL-1A
(2.9)
10 A cubic type
1-pole power relay
1a, 1c
Single
100,000 operations min.
at 120 VAC, 10 A
100,000 operations min.
at 30 VDC, 8 A
Flat power relay with 10, 15 A switching
10 A
1a
Single
300,000 operations min. 100,000 operations min.
at 110 VAC, 15 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 10 A
at 30 VDC, 10 A
100,000 operations min. 100,000 operations min.
at 110 VAC, 5 A
at 250 VAC, 3 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 3 A
at 30 VDC, 3 A
10 A
15 A
5 VDC 100 mA
5 VDC 100 mA
―
5 to 24 VDC
5 to 24 VDC
Approx. 400 mW
Approx. 150 to 200 mW
10,000,000 operations min.
2,000 VAC (Impulse
withstand voltage: 4.5 kV)
20,000,000 operations min.
2,500 VAC (Impulse withstand voltage: 4.5 kV)
―
―
750 VAC
1,000 VAC
―
―
-25°C to 85°C
-25°C to 70°C
―
―
―
―
●
●
●
―
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
100 pcs/tray
Approx. 12 g
G5LE-1A
―
―
―
―
●
5±0.1
(1.7)
18.9±0.1
4-ø1.3 hole
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
22 x 16 x 11
●
●
―
―
―
●
―
●(#187) TP type
―
UL, CSA, EN (TÜV certification)
20 pcs/tube
Approx. 8 g (TP type: approx. 9.6 g)
G5CA-1A(-E)
+0.2
hole (2.25)
4-ø1.3+0
20 x 15 x 10
Features
G4A
2-pole
30.5 x 19.5 x 30.5
30.5 x 19.5 x 30.5
1a
Resistive
load
Rated
load
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1a1b
Single
100,000 operations min. 100,000 operations min.
at 250 VAC, 8 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 8 A
at 30 VDC, 10 A
100,000 operations min. 100,000 operations min.
at 250 VAC, 3.5 A
at 250 VAC, 5 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 3.5 A
at 30 VDC, 5 A
10 A
8A
2a
Single
100,000 operations min. 100,000 operations min.
at 250 VAC, 10 A
at 250 VAC, 15 A
100,000 operations min. 100,000 operations min.
at 24 VAC, 10 A
at 24 VAC, 15 A
100,000 operations min. 100,000 operations min.
at 250 VAC, 7.5 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 24 VDC, 5 A
at 24 VDC, 7.5 A
15 A
10 A
5 VDC 10 mA
5 VDC 100 mA
12
19±0.1
(1.6)
PCB diagram
7.62±0.1
(1.19)
4-ø1.3±0.1 hole
5.1±0.1 (2.8)
G6RN-1
(2.55) 2
G6RL-1
(1.5)
(Unit: mm)
12.2
(5.75) (2.25)
18.9±0.1
3.2±0.1
3.2±0.1
(1.7)
12
3.2±0.1 3.2±0.1
7.62±0.1
19±0.1
(1.6)
5-ø1.3±0.1 hole
12 to 100 VDC
12 VDC, 24 VDC
Approx. 900 mW
50,000,000 operations min.
5,000,000 operations min.
2,000 VAC (Impulse withstand voltage: 6 kV)
4,000 VAC (Impulse withstand voltage: 10 kV)
2,000,000 operations min.
4,500 VAC (Impulse
withstand voltage: 8.5 kV)
Other
12.2
2,000 VAC
2,000 VAC
―
1,500 VAC
1,000 VAC
250 VAC
―
―
-25°C to 70°C
-25°C to 55°C
-25°C to 60°C
●
―
―
●
―
―
―
Ultrasonically cleanable
Full wave rectification
Enclosed
―
●
―
Flux protection
●
―
●
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
●
●
―
●
―
●
―
―
―
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
100 pcs/tray
Approx. 5.6 g
G6C-1114P-US
G6C-2114P-US
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
50 pcs/tray
Approx. 29 g
G4W-1112P-US-TV8
G4W-2212P-US-TV5
●(#250)
―
UL, CSA,
EN/IEC (VDE certification)
50 pcs/tray
Approx. 23 g
G4A-1A-E
Approved standards
Minimum packing unit
Weight
2.54
4-ø1.8+0.1
0
2
2-ø1
elliptical hole
+
2.54
6-ø1.1 hole
2.54 2-ø1.2 hole
2-ø1.8 hole
(Unit: mm)
7.62
(1.1)
10.16
7.62
(1.1)
2-ø1.2 hole
4-ø1.8 hole
6.25±0.1
(4.67)
(4.67)
10.16
10.16
(4.67)
(4.67)
5.75±0.1
12±0.05
(2.4)
(2.4)
10.16
17.78
2.54
2.54
2.54
2.54
2.54
PCB diagram
4-ø1.1 hole
10.16
(2.55) 2
20 A
5 VDC 100 mA
2.54
5-ø1.3+0.2
+0 hole (2.25)
(1.19)
―
Approx. 800 mW
1-coil latching relay
12.7
7.62±0.1
100,000 operations min.
at 250 VAC, 20 A
3 to 24 VDC
1,000 VAC
2-ø1 hole
G5LE-1
5-ø1.3 hole
(1.19)
(1.5)
2.54
1a
Optimal for air conditioner
compressor load and
inverter load
1-pole power relay
1a
Single
Approx. 200 mW
―
(1.19)
7.62±0.1
30.5 x 16 x 23.5
Impulse voltage 10 kV
For switching with power source
with 4 kV dielectric strength
Small 1-pole 10 A (1a1b, 8 A) power relay
Contact form
Contact type
Contact
22.5 x 16.5 x 19
Coil
Rated
load
Low profile
1-pole power relay
with 10 A switching
and 12.3 mm height
1a, 1c
Single
50,000 operations min.
at 250 VAC, 8 A
50,000 operations min.
at 24 VDC, 5 A
Dielectric strength
Resistive
load
28.5 x 10 x 12.3
Enclosure rating Functions
Contact form
Contact type
28.5 x 10 x 15
Small 1-pole power relay
with 8 A switching and
impulse withstand voltage
of 10 kV
1a, 1c
Single
50,000 operations min.
at 250 VAC, 8 A
50,000 operations min.
at 30 VDC, 5 A
Terminal
Features
G4W
1-pole
Outer shape
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Contact
G6C
High capacity type
(5)
15.24
(2.64)
7.62
(5)
15.24
7.62
22±0.1
27.6±0.1
(2.64)
(5.75) (2.25)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G6RN-1A
G6RL-1A
G5LE-1A
G5CA-1A(-E)
G6C-1114P-US
G6C-2114P-US
G4W-1112P-US-TV8
G4W-2212P-US-TV5
G4A-1A-E
1
1
2
2
2
3
1
5
Terminal array diagram/
internal connection
diagram
3
5
G6RN-1
1
3
G6RL-1
1
2
G5LE-1
2
1
2
1
5
2
3
5
4
4
3
Terminal array diagram/
internal connection
diagram
−
3
4
1
−
3
4
5
1
5
3
1
4
3
3
8
+
8
+
6
5
6
4
6
4
2
4
Tab terminal side
1
2
PCB terminal side
1
5
4
3
(BOTTOM VIEW)
12
5
4
(BOTTOM VIEW)
3
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(Take note of coil polarity) (Take note of coil polarity)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW) (BOTTOM VIEW)
13
Power Relay Product Lineup INDEX
Model
G6RN
Power Relay Product Lineup INDEX
G6RL
G5LE
G5CA
Model
Standard type
Outer shape
Terminal
Enclosure rating Functions
Dielectric strength
Coil
Inductive
load
―
―
COSø=0.4
L/R=7 ms
Max. switching current (A)
8A
10 A
Failure rate (mA)
5 VDC 10 mA
5 VDC 10 mA
P level (reference value)
Rated voltage
5 to 24 VDC
3 to 48 VDC
Rated power
Approx. 220 mW
Approx. 220 to 240 mW
consumption
Mechanical endurance
10,000,000 operations min. 10,000,000 operations min.
Between coil and
4,000 VAC (Impulse
5,000 VAC (Impulse
contacts
withstand voltage: 10 kV) withstand voltage: 10 kV)
Between contacts of
―
―
different polarity
Between contacts of
1,000 VAC
1,000 VAC
the same polarity
Between set/reset coil
―
―
Ambient operating
-40°C to 85°C
-40°C to 85°C
temperature
2-coil latching relay
―
―
1-coil latching relay
―
―
Other
―
―
Enclosed
―
―
Flux protection
―
●
Sealed
●
●
PCB terminal
●
●
Surface-mounting Terminals
―
―
Tab terminal
―
―
Screw terminal
―
―
UL, CSA,
UL, C-UL,
Approved standards
EN/IEC (VDE certification) EN/IEC (VDE certification)
Minimum packing unit
20 pcs/tube
100 pcs/tray
Weight
Approx. 9 g
Approx. 7.8 g
G6RN-1A
G6RL-1A
(2.9)
10 A cubic type
1-pole power relay
1a, 1c
Single
100,000 operations min.
at 120 VAC, 10 A
100,000 operations min.
at 30 VDC, 8 A
Flat power relay with 10, 15 A switching
10 A
1a
Single
300,000 operations min. 100,000 operations min.
at 110 VAC, 15 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 10 A
at 30 VDC, 10 A
100,000 operations min. 100,000 operations min.
at 110 VAC, 5 A
at 250 VAC, 3 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 3 A
at 30 VDC, 3 A
10 A
15 A
5 VDC 100 mA
5 VDC 100 mA
―
5 to 24 VDC
5 to 24 VDC
Approx. 400 mW
Approx. 150 to 200 mW
10,000,000 operations min.
2,000 VAC (Impulse
withstand voltage: 4.5 kV)
20,000,000 operations min.
2,500 VAC (Impulse withstand voltage: 4.5 kV)
―
―
750 VAC
1,000 VAC
―
―
-25°C to 85°C
-25°C to 70°C
―
―
―
―
●
●
●
―
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
100 pcs/tray
Approx. 12 g
G5LE-1A
―
―
―
―
●
5±0.1
(1.7)
18.9±0.1
4-ø1.3 hole
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
22 x 16 x 11
●
●
―
―
―
●
―
●(#187) TP type
―
UL, CSA, EN (TÜV certification)
20 pcs/tube
Approx. 8 g (TP type: approx. 9.6 g)
G5CA-1A(-E)
+0.2
hole (2.25)
4-ø1.3+0
20 x 15 x 10
Features
G4A
2-pole
30.5 x 19.5 x 30.5
30.5 x 19.5 x 30.5
1a
Resistive
load
Rated
load
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1a1b
Single
100,000 operations min. 100,000 operations min.
at 250 VAC, 8 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 8 A
at 30 VDC, 10 A
100,000 operations min. 100,000 operations min.
at 250 VAC, 3.5 A
at 250 VAC, 5 A
100,000 operations min. 100,000 operations min.
at 30 VDC, 3.5 A
at 30 VDC, 5 A
10 A
8A
2a
Single
100,000 operations min. 100,000 operations min.
at 250 VAC, 10 A
at 250 VAC, 15 A
100,000 operations min. 100,000 operations min.
at 24 VAC, 10 A
at 24 VAC, 15 A
100,000 operations min. 100,000 operations min.
at 250 VAC, 7.5 A
at 250 VAC, 10 A
100,000 operations min. 100,000 operations min.
at 24 VDC, 5 A
at 24 VDC, 7.5 A
15 A
10 A
5 VDC 10 mA
5 VDC 100 mA
12
19±0.1
(1.6)
PCB diagram
7.62±0.1
(1.19)
4-ø1.3±0.1 hole
5.1±0.1 (2.8)
G6RN-1
(2.55) 2
G6RL-1
(1.5)
(Unit: mm)
12.2
(5.75) (2.25)
18.9±0.1
3.2±0.1
3.2±0.1
(1.7)
12
3.2±0.1 3.2±0.1
7.62±0.1
19±0.1
(1.6)
5-ø1.3±0.1 hole
12 to 100 VDC
12 VDC, 24 VDC
Approx. 900 mW
50,000,000 operations min.
5,000,000 operations min.
2,000 VAC (Impulse withstand voltage: 6 kV)
4,000 VAC (Impulse withstand voltage: 10 kV)
2,000,000 operations min.
4,500 VAC (Impulse
withstand voltage: 8.5 kV)
Other
12.2
2,000 VAC
2,000 VAC
―
1,500 VAC
1,000 VAC
250 VAC
―
―
-25°C to 70°C
-25°C to 55°C
-25°C to 60°C
●
―
―
●
―
―
―
Ultrasonically cleanable
Full wave rectification
Enclosed
―
●
―
Flux protection
●
―
●
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
●
●
―
●
―
●
―
―
―
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
100 pcs/tray
Approx. 5.6 g
G6C-1114P-US
G6C-2114P-US
―
―
UL, CSA, EN/IEC (VDE certification),
EN/IEC (TÜV certification)
50 pcs/tray
Approx. 29 g
G4W-1112P-US-TV8
G4W-2212P-US-TV5
●(#250)
―
UL, CSA,
EN/IEC (VDE certification)
50 pcs/tray
Approx. 23 g
G4A-1A-E
Approved standards
Minimum packing unit
Weight
2.54
4-ø1.8+0.1
0
2
2-ø1
elliptical hole
+
2.54
6-ø1.1 hole
2.54 2-ø1.2 hole
2-ø1.8 hole
(Unit: mm)
7.62
(1.1)
10.16
7.62
(1.1)
2-ø1.2 hole
4-ø1.8 hole
6.25±0.1
(4.67)
(4.67)
10.16
10.16
(4.67)
(4.67)
5.75±0.1
12±0.05
(2.4)
(2.4)
10.16
17.78
2.54
2.54
2.54
2.54
2.54
PCB diagram
4-ø1.1 hole
10.16
(2.55) 2
20 A
5 VDC 100 mA
2.54
5-ø1.3+0.2
+0 hole (2.25)
(1.19)
―
Approx. 800 mW
1-coil latching relay
12.7
7.62±0.1
100,000 operations min.
at 250 VAC, 20 A
3 to 24 VDC
1,000 VAC
2-ø1 hole
G5LE-1
5-ø1.3 hole
(1.19)
(1.5)
2.54
1a
Optimal for air conditioner
compressor load and
inverter load
1-pole power relay
1a
Single
Approx. 200 mW
―
(1.19)
7.62±0.1
30.5 x 16 x 23.5
Impulse voltage 10 kV
For switching with power source
with 4 kV dielectric strength
Small 1-pole 10 A (1a1b, 8 A) power relay
Contact form
Contact type
Contact
22.5 x 16.5 x 19
Coil
Rated
load
Low profile
1-pole power relay
with 10 A switching
and 12.3 mm height
1a, 1c
Single
50,000 operations min.
at 250 VAC, 8 A
50,000 operations min.
at 24 VDC, 5 A
Dielectric strength
Resistive
load
28.5 x 10 x 12.3
Enclosure rating Functions
Contact form
Contact type
28.5 x 10 x 15
Small 1-pole power relay
with 8 A switching and
impulse withstand voltage
of 10 kV
1a, 1c
Single
50,000 operations min.
at 250 VAC, 8 A
50,000 operations min.
at 30 VDC, 5 A
Terminal
Features
G4W
1-pole
Outer shape
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Contact
G6C
High capacity type
(5)
15.24
(2.64)
7.62
(5)
15.24
7.62
22±0.1
27.6±0.1
(2.64)
(5.75) (2.25)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G6RN-1A
G6RL-1A
G5LE-1A
G5CA-1A(-E)
G6C-1114P-US
G6C-2114P-US
G4W-1112P-US-TV8
G4W-2212P-US-TV5
G4A-1A-E
1
1
2
2
2
3
1
5
Terminal array diagram/
internal connection
diagram
3
5
G6RN-1
1
3
G6RL-1
1
2
G5LE-1
2
1
2
1
5
2
3
5
4
4
3
Terminal array diagram/
internal connection
diagram
−
3
4
1
−
3
4
5
1
5
3
1
4
3
3
8
+
8
+
6
5
6
4
6
4
2
4
Tab terminal side
1
2
PCB terminal side
1
5
4
3
(BOTTOM VIEW)
12
5
4
(BOTTOM VIEW)
3
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(Take note of coil polarity) (Take note of coil polarity)
(BOTTOM VIEW)
(BOTTOM VIEW)
(TOP VIEW) (BOTTOM VIEW)
13
Power Relay Product Lineup INDEX
Power Relay Product Lineup INDEX
Model
G2RL
1-pole
Model
1-pole (high capacity type)
1-Pole (TV-3 rating)
G5RL
High capacity (quiet)
Standard (quiet)
2-pole
High capacity (TV-8 rating)
G5RL-U/-K
1-coil latching relay
2-coil latching relay
−E
1A
−U
Outer shape
Outer shape
Rated
load
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
29.0 x 12.7 x 15.7
29.0 x 12.7 x 15.7
16 A high current type
TV-3 compatible type
1a
2-pole 5 A general purpose type
2a, 2c
Single
G2RL-1(A)-E, G2RL-1A-E-ASI
30,000 operations min. at 250 VAC, 16 A
30,000 operations min. at 24 VDC, 16 A
G2RL-1A-E-CV
50,000 operations min. at 250 VAC, 16 A at 105°C
―
―
30,000 operations min.
at 250 VAC, 8 A
30,000 operations min.
at 24 VDC, 8 A
―
12 A
―
16 A
24 VDC 40 mA
Coil
Coil
5 to 48 VDC
20,000,000 operations min.
2,500 VAC
―
-40°C to 85°C, -40°C to 105°C (-CV type)
―
―
―
UL, CSA, EN/IEC (VDE certification)
20 pcs/tube
Approx. 12 g
G2RL-1A-E
G2RL-1A-E-ASI
5 6-ø1.3 hole
4-ø1.3 hole
7.5
7.5
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
G2RL-2A
5 6-ø1.3 hole
5 6-ø1.3 hole
―
12 A
16 A
16 A (N.O.), 5 A (N.C.)
―
5 VDC 100 mA
5 to 24 VDC
Rated power
consumption
5 to 48 VDC
Approx. 400 mW
(Approx. 430 mW
with 48 VDC only)
10,000,000 operations
min.
Approx. 530 mW
1,000,000 operations min.
3 to 24 VDC
5,000,000 operations min.
6,000 VAC (Impulse withstand voltage: 10 kV)
6,000 VAC (Impulse withstand voltage: 10 kV)
―
―
1,000 VAC
1,000 VAC
―
―
-40°C to 85°C
-40°C to 85°C
―
●
UL, CSA, EN/IEC
(VDE certification)
UL, C-UL, EN/IEC (VDE certification)
Minimum packing unit
Weight
G5RL-1A-LN
―
―
●
―
●
―
―
―
100 pcs/tray
Approx. 10 g
G5RL-U1A-E
G5RL-K1A-E
5 ±0.1
4-ø1.3 ±0.1
7.5 ±0.1
(2.3)
PCB diagram
20
20
(2.3)
G2RL-1
(Unit: mm)
20
(2.3)
20
(2.3)
G2RL-1-E
3.5 3.5 5-ø1.3 hole
5
G2RL-2
5
8-ø1.3 hole
5
8-ø1.3 hole
5
(2.5)
(2.5)
(2.5)
7.5
7.5
PCB diagram
4-ø1.3±0.1
6-ø1.3±0.1
7.5±0.1
7.5±0.1
(Unit: mm)
(2.3)
7.5
3.5
±0.1
20±0.1
(2.3)
3.75 ±0.1
(2.3)
20 ±0.1
G5RL-U1-E
(2.3)
20
(2.3)
(2.3)
(2.3)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G2RL-1A
G2RL-1A-E
G2RL-1A-E-ASI
G2RL-2A
3
5
4
1
3
4
1
3
4
1
3
4
8
6
5
8
6
5
8
6
5
G2RL-1
1
5
G2RL-1-E
2
3
4
(BOTTOM VIEW)
1
8
2
7
6
(BOTTOM VIEW)
4
1
5
8
(BOTTOM VIEW)
2
7
3
6
4
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G5RL-1A-E-LN/G5RL-1A-E-TV8
G5RL-U1A-E
G5RL-K1A-E
1
3
1
3
4
5
4
8
6
5
(BOTTOM VIEW)
(BOTTOM VIEW)
3
−
R
+
4
1
9
6
5
8
−
R
+
S
−
3
4
6
5
Note: Take note of coil polarity.
Note: Take note of coil polarity.
G5RL-U1-E
G5RL-K1-E
1
+
S
−
8
5
(BOTTOM VIEW)
14
20 ±0.1
G5RL-1A-LN
1
+
S
−
8
Terminal array diagram/
internal connection
diagram
3.75 ±0.1
(2.3)
20 ±0.1
(BOTTOM VIEW)
G2RL-2
3
5 ±0.1 5 ±0.1
9-ø1.3 ±0.1
(3.75)
7.5 ±0.1
(2.3)
(BOTTOM VIEW)
1
Terminal array diagram/
internal connection
diagram
20
20 ±0.1
G5RL-K1-E
5±0.1 5±0.1
8-ø1.3 ±0.1
5
±0.1
20±0.1
5 ±0.1
7-ø1.3 ±0.1
(3.75)
7.5 ±0.1
7.5 ±0.1
20
●
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 10 g
G5RL-1A-E-LN/G5RL-1A-E-TV8
7.5
7.5
5 to 24 VDC
Approx. 750 mW
(Approx. 840 mW
with 24 VDC only)
Approx. 600 mW
―
―
―
―
●
―
●
―
―
―
(2.5)
(2.5)
50,000 operations min. at 250 VAC, 16 A
50,000 operations min. at 24 VDC, 16 A
29.0 x 12.7 x 15.7
Small latching relay with low profile
and 16 A switching
1a, 1c
Single
50,000 operations min. at 250 VAC 16 A (N.O.)
50,000 operations min. at 250 VAC 5 A (N.C.)
50,000 operations min. at 24 VDC 16 A (N.O.)
50,000 operations min. at 24 VDC 5 A (N.C.)
―
Approved standards
(2.5)
(2.5)
Rated
load
100,000 operations min.
at 250 VAC, 12 A
100,000 operations min.
at 24 VDC, 12 A
Enclosure rating Functions
Terminal
Enclosure rating Functions
―
―
―
―
●
●
●
3.5
Resistive
load
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Screw terminal
1,000 VAC
G2RL-1A
1a
Single
Dielectric strength
Dielectric strength
―
29.0 x 12.7 x 15.7
Low profile power relay with a TV-8 rating and low noise
Mechanical endurance
5,000 VAC (Impulse withstand voltage: 10 kV)
29.0 x 12.7 x 15.7
Contact form
Contact type
8A
5 to 24 VDC: Approx. 400 mW, 48 VDC: Approx. 430 mW
29.0 x 12.7 x 15.7
Features
Contact
50,000 operations min.
at 250 VAC, 12 A
30,000 operations min.
at 24 VDC, 12 A
Resistive
load
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
29.0 x 12.7 x 15.7
Terminal
Contact
Shape (max. value mm)
29.0 x 12.7 x 15.7
Length (L) x Width (w) x Height (H)
1-pole 10 A general purpose type
Features
Contact form
1a, 1c
Contact type
−
R
+
2
3
4
1
9
7
6
5
8
−
R
+
S
−
2
3
4
7
6
5
Note: Take note of coil polarity.
Note: Take note of coil polarity.
(BOTTOM VIEW)
(BOTTOM VIEW)
15
Power Relay Product Lineup INDEX
Power Relay Product Lineup INDEX
Model
G2RL
1-pole
Model
1-pole (high capacity type)
1-Pole (TV-3 rating)
G5RL
High capacity (quiet)
Standard (quiet)
2-pole
High capacity (TV-8 rating)
G5RL-U/-K
1-coil latching relay
2-coil latching relay
−E
1A
−U
Outer shape
Outer shape
Rated
load
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power
consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
29.0 x 12.7 x 15.7
29.0 x 12.7 x 15.7
16 A high current type
TV-3 compatible type
1a
2-pole 5 A general purpose type
2a, 2c
Single
G2RL-1(A)-E, G2RL-1A-E-ASI
30,000 operations min. at 250 VAC, 16 A
30,000 operations min. at 24 VDC, 16 A
G2RL-1A-E-CV
50,000 operations min. at 250 VAC, 16 A at 105°C
―
―
30,000 operations min.
at 250 VAC, 8 A
30,000 operations min.
at 24 VDC, 8 A
―
12 A
―
16 A
24 VDC 40 mA
Coil
Coil
5 to 48 VDC
20,000,000 operations min.
2,500 VAC
―
-40°C to 85°C, -40°C to 105°C (-CV type)
―
―
―
UL, CSA, EN/IEC (VDE certification)
20 pcs/tube
Approx. 12 g
G2RL-1A-E
G2RL-1A-E-ASI
5 6-ø1.3 hole
4-ø1.3 hole
7.5
7.5
Inductive
load
COSø=0.4
L/R=7 ms
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
G2RL-2A
5 6-ø1.3 hole
5 6-ø1.3 hole
―
12 A
16 A
16 A (N.O.), 5 A (N.C.)
―
5 VDC 100 mA
5 to 24 VDC
Rated power
consumption
5 to 48 VDC
Approx. 400 mW
(Approx. 430 mW
with 48 VDC only)
10,000,000 operations
min.
Approx. 530 mW
1,000,000 operations min.
3 to 24 VDC
5,000,000 operations min.
6,000 VAC (Impulse withstand voltage: 10 kV)
6,000 VAC (Impulse withstand voltage: 10 kV)
―
―
1,000 VAC
1,000 VAC
―
―
-40°C to 85°C
-40°C to 85°C
―
●
UL, CSA, EN/IEC
(VDE certification)
UL, C-UL, EN/IEC (VDE certification)
Minimum packing unit
Weight
G5RL-1A-LN
―
―
●
―
●
―
―
―
100 pcs/tray
Approx. 10 g
G5RL-U1A-E
G5RL-K1A-E
5 ±0.1
4-ø1.3 ±0.1
7.5 ±0.1
(2.3)
PCB diagram
20
20
(2.3)
G2RL-1
(Unit: mm)
20
(2.3)
20
(2.3)
G2RL-1-E
3.5 3.5 5-ø1.3 hole
5
G2RL-2
5
8-ø1.3 hole
5
8-ø1.3 hole
5
(2.5)
(2.5)
(2.5)
7.5
7.5
PCB diagram
4-ø1.3±0.1
6-ø1.3±0.1
7.5±0.1
7.5±0.1
(Unit: mm)
(2.3)
7.5
3.5
±0.1
20±0.1
(2.3)
3.75 ±0.1
(2.3)
20 ±0.1
G5RL-U1-E
(2.3)
20
(2.3)
(2.3)
(2.3)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G2RL-1A
G2RL-1A-E
G2RL-1A-E-ASI
G2RL-2A
3
5
4
1
3
4
1
3
4
1
3
4
8
6
5
8
6
5
8
6
5
G2RL-1
1
5
G2RL-1-E
2
3
4
(BOTTOM VIEW)
1
8
2
7
6
(BOTTOM VIEW)
4
1
5
8
(BOTTOM VIEW)
2
7
3
6
4
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
G5RL-1A-E-LN/G5RL-1A-E-TV8
G5RL-U1A-E
G5RL-K1A-E
1
3
1
3
4
5
4
8
6
5
(BOTTOM VIEW)
(BOTTOM VIEW)
3
−
R
+
4
1
9
6
5
8
−
R
+
S
−
3
4
6
5
Note: Take note of coil polarity.
Note: Take note of coil polarity.
G5RL-U1-E
G5RL-K1-E
1
+
S
−
8
5
(BOTTOM VIEW)
14
20 ±0.1
G5RL-1A-LN
1
+
S
−
8
Terminal array diagram/
internal connection
diagram
3.75 ±0.1
(2.3)
20 ±0.1
(BOTTOM VIEW)
G2RL-2
3
5 ±0.1 5 ±0.1
9-ø1.3 ±0.1
(3.75)
7.5 ±0.1
(2.3)
(BOTTOM VIEW)
1
Terminal array diagram/
internal connection
diagram
20
20 ±0.1
G5RL-K1-E
5±0.1 5±0.1
8-ø1.3 ±0.1
5
±0.1
20±0.1
5 ±0.1
7-ø1.3 ±0.1
(3.75)
7.5 ±0.1
7.5 ±0.1
20
●
―
UL, CSA, EN/IEC (VDE certification)
100 pcs/tray
Approx. 10 g
G5RL-1A-E-LN/G5RL-1A-E-TV8
7.5
7.5
5 to 24 VDC
Approx. 750 mW
(Approx. 840 mW
with 24 VDC only)
Approx. 600 mW
―
―
―
―
●
―
●
―
―
―
(2.5)
(2.5)
50,000 operations min. at 250 VAC, 16 A
50,000 operations min. at 24 VDC, 16 A
29.0 x 12.7 x 15.7
Small latching relay with low profile
and 16 A switching
1a, 1c
Single
50,000 operations min. at 250 VAC 16 A (N.O.)
50,000 operations min. at 250 VAC 5 A (N.C.)
50,000 operations min. at 24 VDC 16 A (N.O.)
50,000 operations min. at 24 VDC 5 A (N.C.)
―
Approved standards
(2.5)
(2.5)
Rated
load
100,000 operations min.
at 250 VAC, 12 A
100,000 operations min.
at 24 VDC, 12 A
Enclosure rating Functions
Terminal
Enclosure rating Functions
―
―
―
―
●
●
●
3.5
Resistive
load
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating
temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting Terminals
Tab terminal
Screw terminal
1,000 VAC
G2RL-1A
1a
Single
Dielectric strength
Dielectric strength
―
29.0 x 12.7 x 15.7
Low profile power relay with a TV-8 rating and low noise
Mechanical endurance
5,000 VAC (Impulse withstand voltage: 10 kV)
29.0 x 12.7 x 15.7
Contact form
Contact type
8A
5 to 24 VDC: Approx. 400 mW, 48 VDC: Approx. 430 mW
29.0 x 12.7 x 15.7
Features
Contact
50,000 operations min.
at 250 VAC, 12 A
30,000 operations min.
at 24 VDC, 12 A
Resistive
load
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
29.0 x 12.7 x 15.7
Terminal
Contact
Shape (max. value mm)
29.0 x 12.7 x 15.7
Length (L) x Width (w) x Height (H)
1-pole 10 A general purpose type
Features
Contact form
1a, 1c
Contact type
−
R
+
2
3
4
1
9
7
6
5
8
−
R
+
S
−
2
3
4
7
6
5
Note: Take note of coil polarity.
Note: Take note of coil polarity.
(BOTTOM VIEW)
(BOTTOM VIEW)
15
Power Relay Product Lineup INDEX
Model
G2RG
Power Relay Product Lineup INDEX
G2R
1-pole (high capacity type)
1-pole
G7L
2-pole
Model
G7L-X (standard)
G7L-X-L (general purpose)
G7L
G7L-PV
52.5 x 35.5 x 41 (PCB terminal)
52.5 x 35.5 x 41
52.5 x 35.5 x 41
Solar system
Relay for PV inverter
2a
Double break
600 to 1,000 VDC isolation/switching
thanks to 2-pole series wiring
2a
Double break
100 operations at 1,000 VDC
25 A (standard)
6,000 operations at 600 VDC
25 A (standard)
100 operations at 1,000 VDC
20 A (general purpose)
6,000 operations at 600 VDC
20 A (general purpose)
Outer shape
Outer shape
2.5
(2.7)
2.5
6-ø1.3 hole
(2.1)
20
(2.1)
G2R-1
7.5
(Unit: mm)
3.5
(2.1)
(2.1)
(2.7)
(2.1)
2.5
Inductive
load
COSø=0.4
L/R=7 ms
100,000 operations min. at 220 VAC, 25 A
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
30 A
30,000 operations min.
at 280 VAC, 30 A
100,000 operations min.
at 220 VAC, 20 A
30,000 operations min.
at 280 VAC, 30 A
(COSø=0.8)
―
20 A
30 A
25 A (standard),
20 A (general purpose)
5 VDC 100 mA
5 VDC 100 mA
5 VDC 100 mA
6 to 100 VDC, 12 to 200/240 VAC
DC: Approx. 1.9 W, AC: Approx. 1.7 to 2.5 VA
1,000,000 operations min.
4,000 VAC (Impulse withstand voltage: 10 kV)
―
12 VDC, 24 VDC
12 VDC, 24 VDC
2.3 W
Approx. 2.3 W
1,000,000 operations min. 1,000,000 operations min.
4,000 VAC (Impulse
4,000 VAC
withstand voltage: 10 kV)
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
―
-25°C to 60°C
―
―
Test button (excluding P type)
●
―
―
―
―
-25°C to 85°C
―
―
―
●
―
―
●
―
-40°C to 85°C
―
―
―
―
●
―
●
―
―
―
●
―
●
―
UL, CSA, EN (TÜV certification)
20 pcs/tray
Approx. 90 g (tab terminal), approx. 120 g (screw terminal), approx. 100 g (PCB terminal)
G7L-1A-P
G7L-2A-P
―
―
UL, VDE
20 pcs/tray
Approx. 100 g
G7L-2A-P-PV
―
―
UL, EN/IEC (VDE certification)
20 pcs/tray
Approx. 100 g
G7L-2A-X(-L)
36.8
3.2
●
36.8
(8.4)
PCB diagram
1.2
(Unit: mm)
14.4
17.7
(2.7)
7.5
(BOTTOM VIEW)
G7L-1A-P
3.2
36.8
(8.4)
1.2
14.4
(8.9)
4-1.2 x 3.2 square hole
(2.7)
100,000 operations min.
at 220 VAC, 20 A
25 A
8-ø1.3 hole
2.5
7.5
5-ø1.3 hole
100,000 operations min.
at 220 VAC, 25 A
Rated
load
2.5
17.7
(8.4)
1.2
14.4
(8.9)
6-1.2 x 3.2 square hole
(BOTTOM VIEW)
G7L-2A-P
36.8
3.2
17.7
(8.4)
14.4
1.2
5
5
(2.1)
(2.1)
(8.9)
(8.9)
6-1.2 x 3.2 square hole
6-1.2 x 3.2 square hole
(BOTTOM VIEW)
(BOTTOM VIEW)
G7L-2A-P-PV
G7L-2A-X(-L)
5
5
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
2
G2RG-2A4
G2RL-1A
G2R-1A-E
G2R-2A
(ー)
1
3
4
3
5
4
1
3
4
1
3
4
8
6
5
8
6
5
G2R-1
8
6
5
1
G2RL-1-E
2
3
(BOTTOM VIEW)
16
4
(BOTTOM VIEW)
6
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
(BOTTOM VIEW)
8
(+)
1
0
G2RL-2
1
(BOTTOM VIEW)
4
Take note of polarity.
(There is no coil polarity)
2-pole series wiring diagram
Terminal array diagram/
internal connection
diagram
2
(ー)
5
1
0
(2.1)
20
20
1
17.7
20
(2.1)
Terminal array diagram/
internal connection
diagram
5
G2RL-2
8-ø1.3 hole
2.5
7.5
(2.1)
20
(2.1)
G2RL-1-E
3.5
(2.1)
20
5
100,000 operations min.
at 220 VAC, 30 A
3.2
20
(2.7)
PCB diagram
Resistive
load
7.5
7.5
4-ø1.3 hole
Contact form
Contact type
(2.7)
(2.7)
7.5
5
6-ø1.3 hole
2.5
6-ø1.3 hole
2.5
・Multi polar power relay, strong against sudden drops in voltage
・Wide range with 100 V and 200 V coils
1a, 2a (-P type)
1a (-T□, B□ type)
2a (-T□, B□ type)
Double break
Features
Contact
Contact
Coil
Dielectric strength
Enclosure rating Functions
Terminal
3.5
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Coil
29 x 13 x 25.5
Dielectric strength
29 x 13 x 25.5
Enclosure rating Functions
29.0 x 13.5 x 25.5
Small power relay with high voltage 5 A
switching at 110 VDC
1-pole 10 A general purpose type
16 A high capacity type
2-pole 5 A general purpose type
Features
(1a contact with 2-pole series wiring at 1.5 mm)
Contact form
2a
1a, 1c
2a, 2c
Contact type
Single
Single
100,000 operations min.
100,000 operations min.
10,000 operations min.
100,000 operations min.
at 250 VAC, 5 A
at 250 VAC, 16 A
at 250 VAC 8 A
at 250 VAC, 10 A
Resistive
100,000 operations min.
100,000 operations min.
10,000 operations min. at 110
100,000 operations min.
load
at 30 VDC, 5 A (Flux protection)
at 30 VDC, 16 A
VDC 5 A (with 2-pole series wiring) at 30 VDC, 10 A (Flux protection)
Rated
load
100,000 operations min.
100,000 operations min.
100,000 operations min.
Inductive
at 250 VAC, 2 A
at 250 VAC, 8 A
at 250 VAC, 7.5 A
load
―
100,000 operations min.
100,000 operations min.
100,000 operations min.
COSø=0.4
at 30 VDC, 3 A (Flux protection)
at 30 VDC, 8 A
at 30 VDC, 5 A (Flux protection)
L/R=7 ms
5 A (Flux protection)
10 A (Flux protection)
16 A
Max. switching current (A)
8A
4 A (Sealed)
8 A (Sealed)
Failure rate (mA)
5 VDC 10 mA
5 VDC 100 mA
5 VDC 10 mA
P level (reference value)
Rated voltage
12 VDC, 24 VDC
5 to 100 VDC, 12 to 200 VAC
Rated power
Approx. 800 mW
DC: Approx. 530 mW, AC: Approx. 900 mVA
consumption
Mechanical endurance
1,000,000 operations min.
DC coil specifications: 20,000,000 operations min., AC coil specifications: 10,000,000 operations min.
Between coil and
5,000 VAC
5,000 VAC (Impulse withstand voltage: 10 kV)
contacts
(Impulse withstand voltage: 10 kV)
Between contacts of
3,000 VAC
3,000 VAC
―
different polarity
Between contacts of
1,000 VAC
1,000 VAC
the same polarity
Between set/reset coil
1,000 VAC
1,000 VAC
―
―
Ambient operating
-40°C to 70°C
-40°C to 70°C
temperature
2-coil latching relay
―
●
―
●
1-coil latching relay
―
―
Other
Ultrasonically cleanable, full wave rectification (excluding high current type)
―
Enclosed
―
● (Tab terminal)
―
Flux protection
―
●
Sealed
●
●
―
●
PCB terminal
●
●
Surface-mounting Terminals
―
―
Tab terminal
―
●(#187)
―
Screw terminal
―
―
Approved standards
UL, CSA, EN/IEC (VDE certification)
UL, CSA, EN/IEC (VDE certification), EN (TÜV certification)
Minimum packing unit
50 pcs/tray
50 pcs/tray (100 pcs/tray for tab terminal)
Weight
Approx. 17.2 g
Approx. 17 g (Approx. 20 g for tab terminal)
G2RG-2A4
G2RL-1A
G2R-1A-E
G2R-2A
Terminal
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
4
6
8
(+)
Use this product in a 2-pole series connection.
(BOTTOM VIEW)
17
Power Relay Product Lineup INDEX
Model
G2RG
Power Relay Product Lineup INDEX
G2R
1-pole (high capacity type)
1-pole
G7L
2-pole
Model
G7L-X (standard)
G7L-X-L (general purpose)
G7L
G7L-PV
52.5 x 35.5 x 41 (PCB terminal)
52.5 x 35.5 x 41
52.5 x 35.5 x 41
Solar system
Relay for PV inverter
2a
Double break
600 to 1,000 VDC isolation/switching
thanks to 2-pole series wiring
2a
Double break
100 operations at 1,000 VDC
25 A (standard)
6,000 operations at 600 VDC
25 A (standard)
100 operations at 1,000 VDC
20 A (general purpose)
6,000 operations at 600 VDC
20 A (general purpose)
Outer shape
Outer shape
2.5
(2.7)
2.5
6-ø1.3 hole
(2.1)
20
(2.1)
G2R-1
7.5
(Unit: mm)
3.5
(2.1)
(2.1)
(2.7)
(2.1)
2.5
Inductive
load
COSø=0.4
L/R=7 ms
100,000 operations min. at 220 VAC, 25 A
Max. switching current (A)
Failure rate (mA)
P level (reference value)
Rated voltage
Rated power consumption
Mechanical endurance
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set/reset coil
Ambient operating temperature
2-coil latching relay
1-coil latching relay
Other
Enclosed
Flux protection
Sealed
PCB terminal
Surface-mounting
Terminals
Tab terminal
Screw terminal
Approved standards
Minimum packing unit
Weight
30 A
30,000 operations min.
at 280 VAC, 30 A
100,000 operations min.
at 220 VAC, 20 A
30,000 operations min.
at 280 VAC, 30 A
(COSø=0.8)
―
20 A
30 A
25 A (standard),
20 A (general purpose)
5 VDC 100 mA
5 VDC 100 mA
5 VDC 100 mA
6 to 100 VDC, 12 to 200/240 VAC
DC: Approx. 1.9 W, AC: Approx. 1.7 to 2.5 VA
1,000,000 operations min.
4,000 VAC (Impulse withstand voltage: 10 kV)
―
12 VDC, 24 VDC
12 VDC, 24 VDC
2.3 W
Approx. 2.3 W
1,000,000 operations min. 1,000,000 operations min.
4,000 VAC (Impulse
4,000 VAC
withstand voltage: 10 kV)
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
2,000 VAC
―
-25°C to 60°C
―
―
Test button (excluding P type)
●
―
―
―
―
-25°C to 85°C
―
―
―
●
―
―
●
―
-40°C to 85°C
―
―
―
―
●
―
●
―
―
―
●
―
●
―
UL, CSA, EN (TÜV certification)
20 pcs/tray
Approx. 90 g (tab terminal), approx. 120 g (screw terminal), approx. 100 g (PCB terminal)
G7L-1A-P
G7L-2A-P
―
―
UL, VDE
20 pcs/tray
Approx. 100 g
G7L-2A-P-PV
―
―
UL, EN/IEC (VDE certification)
20 pcs/tray
Approx. 100 g
G7L-2A-X(-L)
36.8
3.2
●
36.8
(8.4)
PCB diagram
1.2
(Unit: mm)
14.4
17.7
(2.7)
7.5
(BOTTOM VIEW)
G7L-1A-P
3.2
36.8
(8.4)
1.2
14.4
(8.9)
4-1.2 x 3.2 square hole
(2.7)
100,000 operations min.
at 220 VAC, 20 A
25 A
8-ø1.3 hole
2.5
7.5
5-ø1.3 hole
100,000 operations min.
at 220 VAC, 25 A
Rated
load
2.5
17.7
(8.4)
1.2
14.4
(8.9)
6-1.2 x 3.2 square hole
(BOTTOM VIEW)
G7L-2A-P
36.8
3.2
17.7
(8.4)
14.4
1.2
5
5
(2.1)
(2.1)
(8.9)
(8.9)
6-1.2 x 3.2 square hole
6-1.2 x 3.2 square hole
(BOTTOM VIEW)
(BOTTOM VIEW)
G7L-2A-P-PV
G7L-2A-X(-L)
5
5
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
2
G2RG-2A4
G2RL-1A
G2R-1A-E
G2R-2A
(ー)
1
3
4
3
5
4
1
3
4
1
3
4
8
6
5
8
6
5
G2R-1
8
6
5
1
G2RL-1-E
2
3
(BOTTOM VIEW)
16
4
(BOTTOM VIEW)
6
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
(BOTTOM VIEW)
8
(+)
1
0
G2RL-2
1
(BOTTOM VIEW)
4
Take note of polarity.
(There is no coil polarity)
2-pole series wiring diagram
Terminal array diagram/
internal connection
diagram
2
(ー)
5
1
0
(2.1)
20
20
1
17.7
20
(2.1)
Terminal array diagram/
internal connection
diagram
5
G2RL-2
8-ø1.3 hole
2.5
7.5
(2.1)
20
(2.1)
G2RL-1-E
3.5
(2.1)
20
5
100,000 operations min.
at 220 VAC, 30 A
3.2
20
(2.7)
PCB diagram
Resistive
load
7.5
7.5
4-ø1.3 hole
Contact form
Contact type
(2.7)
(2.7)
7.5
5
6-ø1.3 hole
2.5
6-ø1.3 hole
2.5
・Multi polar power relay, strong against sudden drops in voltage
・Wide range with 100 V and 200 V coils
1a, 2a (-P type)
1a (-T□, B□ type)
2a (-T□, B□ type)
Double break
Features
Contact
Contact
Coil
Dielectric strength
Enclosure rating Functions
Terminal
3.5
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
Coil
29 x 13 x 25.5
Dielectric strength
29 x 13 x 25.5
Enclosure rating Functions
29.0 x 13.5 x 25.5
Small power relay with high voltage 5 A
switching at 110 VDC
1-pole 10 A general purpose type
16 A high capacity type
2-pole 5 A general purpose type
Features
(1a contact with 2-pole series wiring at 1.5 mm)
Contact form
2a
1a, 1c
2a, 2c
Contact type
Single
Single
100,000 operations min.
100,000 operations min.
10,000 operations min.
100,000 operations min.
at 250 VAC, 5 A
at 250 VAC, 16 A
at 250 VAC 8 A
at 250 VAC, 10 A
Resistive
100,000 operations min.
100,000 operations min.
10,000 operations min. at 110
100,000 operations min.
load
at 30 VDC, 5 A (Flux protection)
at 30 VDC, 16 A
VDC 5 A (with 2-pole series wiring) at 30 VDC, 10 A (Flux protection)
Rated
load
100,000 operations min.
100,000 operations min.
100,000 operations min.
Inductive
at 250 VAC, 2 A
at 250 VAC, 8 A
at 250 VAC, 7.5 A
load
―
100,000 operations min.
100,000 operations min.
100,000 operations min.
COSø=0.4
at 30 VDC, 3 A (Flux protection)
at 30 VDC, 8 A
at 30 VDC, 5 A (Flux protection)
L/R=7 ms
5 A (Flux protection)
10 A (Flux protection)
16 A
Max. switching current (A)
8A
4 A (Sealed)
8 A (Sealed)
Failure rate (mA)
5 VDC 10 mA
5 VDC 100 mA
5 VDC 10 mA
P level (reference value)
Rated voltage
12 VDC, 24 VDC
5 to 100 VDC, 12 to 200 VAC
Rated power
Approx. 800 mW
DC: Approx. 530 mW, AC: Approx. 900 mVA
consumption
Mechanical endurance
1,000,000 operations min.
DC coil specifications: 20,000,000 operations min., AC coil specifications: 10,000,000 operations min.
Between coil and
5,000 VAC
5,000 VAC (Impulse withstand voltage: 10 kV)
contacts
(Impulse withstand voltage: 10 kV)
Between contacts of
3,000 VAC
3,000 VAC
―
different polarity
Between contacts of
1,000 VAC
1,000 VAC
the same polarity
Between set/reset coil
1,000 VAC
1,000 VAC
―
―
Ambient operating
-40°C to 70°C
-40°C to 70°C
temperature
2-coil latching relay
―
●
―
●
1-coil latching relay
―
―
Other
Ultrasonically cleanable, full wave rectification (excluding high current type)
―
Enclosed
―
● (Tab terminal)
―
Flux protection
―
●
Sealed
●
●
―
●
PCB terminal
●
●
Surface-mounting Terminals
―
―
Tab terminal
―
●(#187)
―
Screw terminal
―
―
Approved standards
UL, CSA, EN/IEC (VDE certification)
UL, CSA, EN/IEC (VDE certification), EN (TÜV certification)
Minimum packing unit
50 pcs/tray
50 pcs/tray (100 pcs/tray for tab terminal)
Weight
Approx. 17.2 g
Approx. 17 g (Approx. 20 g for tab terminal)
G2RG-2A4
G2RL-1A
G2R-1A-E
G2R-2A
Terminal
Shape (max. value mm)
Length (L) x Width (w) x Height (H)
(BOTTOM VIEW)
(BOTTOM VIEW)
(BOTTOM VIEW)
4
6
8
(+)
Use this product in a 2-pole series connection.
(BOTTOM VIEW)
17
Applications
Applications
For many devices and applications in every field
From household use to public infrastructure, these products can be used in every field and for all purposes with many variations.
Signal Relay
Power Relay
You can use single relays in the following devices for system switching, signal switching, and more.
Communication equipment
Telephone switchboard, PBX*1, fax machines
IP telephones, various modems
Network devices (switches, routers, etc.)
Applications: system switching,
dial pulse transmission
*1.Private Branch exchange
Broadcasting and video equipment
Can be used in a wide range of fields where power relays directly switch the loads, such as in motors, lamps, heaters, etc.
Wireless devices
Household appliances
Industrial equipment
Broadcasting equipment
Satellite broadcasting receivers
Various wireless devices,
GPS*2 devices, etc.
Machine tools, molding machines, welding machines,
mounters and other industrial robots
Applications: redundancy switching,
system switching
Applications: system switching
*2.Global Positioning System
Applications: control of motors, heaters, etc.
Shutter doors, lights
Applications: control of motors, lighting, etc.
Broadcasting equipment
Network device
Wireless device
PBX, switching equipment
Medical and health-related equipment
Ultrasonic echography equipment,
various treatment devices
Various health and beauty devices
Applications: sensor switching,
system switching
Machine tool
Satellite broadcasting device
Automatic shutter door
Robot
Lights
Household devices
Testing and measurement equipment
Entertainment devices
Various oscilloscope measurement devices
Various IC tester inspection equipment
Game machines, peripheral equipment, etc.
UPS, switching power
Air conditioners, washing machines, refrigerators, etc.
Applications: information output
Applications: power control
Applications: control of compressors, pumps, motors, heaters, etc.
Applications: input/output switching,
power switching, etc.
Power equipment
20 eco
ATE (Automated Test Equipment)
UPS
Ultrasonic echography equipment
Switching power
Security devices
Industrial equipment
Other devices
Gas detectors and other disaster prevention devices
Alarm systems and other crime prevention devices
Machine tools, molding machines, welding machines
Mounters and other industrial robots
OA devices, AV devices, electric appliances
PLC, temperature regulators, timers, various I/O devices
Applications: alarm output
Applications: system switching, control switching
Applications: system switching, etc.
Applications: control external device load
Washing machine
Refrigerator
FA equipment
Multimedia
Control panel
Detector
PLC
Machine tool
18
Air conditioner
Game machine
Oscilloscope
Temperature regulator
Timer
Various I/O devices
Multifunction machine
19
Applications
Applications
For many devices and applications in every field
From household use to public infrastructure, these products can be used in every field and for all purposes with many variations.
Signal Relay
Power Relay
You can use single relays in the following devices for system switching, signal switching, and more.
Communication equipment
Telephone switchboard, PBX*1, fax machines
IP telephones, various modems
Network devices (switches, routers, etc.)
Applications: system switching,
dial pulse transmission
*1.Private Branch exchange
Broadcasting and video equipment
Can be used in a wide range of fields where power relays directly switch the loads, such as in motors, lamps, heaters, etc.
Wireless devices
Household appliances
Industrial equipment
Broadcasting equipment
Satellite broadcasting receivers
Various wireless devices,
GPS*2 devices, etc.
Machine tools, molding machines, welding machines,
mounters and other industrial robots
Applications: redundancy switching,
system switching
Applications: system switching
*2.Global Positioning System
Applications: control of motors, heaters, etc.
Shutter doors, lights
Applications: control of motors, lighting, etc.
Broadcasting equipment
Network device
Wireless device
PBX, switching equipment
Medical and health-related equipment
Ultrasonic echography equipment,
various treatment devices
Various health and beauty devices
Applications: sensor switching,
system switching
Machine tool
Satellite broadcasting device
Automatic shutter door
Robot
Lights
Household devices
Testing and measurement equipment
Entertainment devices
Various oscilloscope measurement devices
Various IC tester inspection equipment
Game machines, peripheral equipment, etc.
UPS, switching power
Air conditioners, washing machines, refrigerators, etc.
Applications: information output
Applications: power control
Applications: control of compressors, pumps, motors, heaters, etc.
Applications: input/output switching,
power switching, etc.
Power equipment
20 eco
ATE (Automated Test Equipment)
UPS
Ultrasonic echography equipment
Switching power
Security devices
Industrial equipment
Other devices
Gas detectors and other disaster prevention devices
Alarm systems and other crime prevention devices
Machine tools, molding machines, welding machines
Mounters and other industrial robots
OA devices, AV devices, electric appliances
PLC, temperature regulators, timers, various I/O devices
Applications: alarm output
Applications: system switching, control switching
Applications: system switching, etc.
Applications: control external device load
Washing machine
Refrigerator
FA equipment
Multimedia
Control panel
Detector
PLC
Machine tool
18
Air conditioner
Game machine
Oscilloscope
Temperature regulator
Timer
Various I/O devices
Multifunction machine
19
Offering the global standard in safety.
Meeting our customers’ every need
with numerous variations.
Electrical
Mechanical
Relay
Selection Guide
Signal Relay
Power Relay
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2007-2018 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. Y225-E1-02
0318(0317)(O)
PCB Relay