G2RL1EDC5

G2RL1EDC5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON ELECTRONIC COMPONENTS - G2RL1EDC5 - RELAY, SPDT, 240VAC, 24VDC, 3A

  • 数据手册
  • 价格&库存
G2RL1EDC5 数据手册
G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments • A wide variety of single pole, double pole, high-capacity (16 A) type and high-sensitivity type (250 mW) Relays are available. • Low profile; 15.7 mm max. in height. • Conforms to VDE (EN61810-1), UL508 and CSA22.2. • IEC/EN 60335-1 conformed. (-HA Model) • Satisfies ambient operating temperature requirement of 85°C and 105°C (-CV Model). • Clearance and creepage distance: 8 mm / 8 mm min. • Coil insulation system: Class F (UL1446). • G2RL-1A-E-ASI: TV3 Rating models available. RoHS Compliant ■Model Number Legend ■Application Examples G2RL- @ @@ -@ -@ - @- @ ——— — — — — 1 2 3 4 5 1. Number of poles 1 : 1 pole 2 : 2 pole 2. Contact Form None : SPDT (1c) A : SPST-NO (1a) 3. Enclosure rating None : Flux protection 4 : Sealed 4. Classification None : Standard E : High-capacity H : High-sensitivity 6 7 5. Special Requirement None : Standard CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN60335-1 7. Contact material None : Standard (Ag-alloy, Cd free) ASI : AgSnIn G 2 R L • Home appliances • OA equipments • Industrial machinery ■Ordering Information Terminal Shape Market Code Classification Contact form SPST-NO (1a) SPDT (1c) Standard DPST-NO (2a) DPDT (2c) General purpose SPST-NO (1a) PCB terminals High-capacity SPDT (1c) Enclosure rating Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed SPST-NO (1a) High-sensitivity Home Appliance Standard High-capacity SPDT (1c) DPST-NO (2a) DPDT (2c) SPST-NO (1a) SPDT (1c) Flux protection Model G2RL-1A G2RL-1A4 G2RL-1 G2RL-14 G2RL-2A G2RL-2A4 G2RL-2 G2RL-24 G2RL-1A-E G2RL-1A-E-ASI G2RL-1A4-E G2RL-1-E G2RL-14-E G2RL-1A-E-CV G2RL-1A-H G2RL-1-H G2RL-2A-HA G2RL-2-HA G2RL-1A-E-HA G2RL-1-E-HA Rated coil voltage Minimum packing unit 5 VDC 12 VDC 24 VDC 48 VDC 20 pcs/tube 12 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case will be marked as @@VDC. Note 2. Place your order in tube (20 pcs/tube) units. Note 3. Contact your OMRON sales representative for sealed models. 1 G2RL PCB Power Relay ■Ratings ●Coil Item Standard Highsensitivity Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC Rated current (mA) Must operate voltage Must release voltage (V) (V) % of rated voltage Coil resistance (Ω) 80.0 33.3 16.7 8.96 20.8 10.42 62.5 360 1,440 5,358 576 2,304 Max. voltage (V) Power consumption (mW) Approx. 400 70% max. 130% (at 85°C) 10% min. Approx. 430 75% max. Approx. 250 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ●Contacts Classification Item Model Standard type (resistive load) G2RL-1A G2RL-1 High-capacity type (resistive load) G2RL-2A G2RL-2 G2RL-1A-E (-CV, -ASI) Contact type Rated carry current G 2 R L G2RL-1-H Ag-alloy (Cd free) 12 A at 250 VAC 12 A at 24 VDC (See note) 8 A at 250 VAC 8 A at 30 VDC (See note) 12 A (See note) 8 A (70°C)/5 A (85°C) (See note) 12 A 8A Max. switching voltage Max. switching current G2RL-1A-H Single Contact material Rated load High-sensitivity type (resistive load) G2RL-1-E 16 A at 250 VAC 16 A at 24 VDC (See note) 10 A at 250 VAC (See note) 16 A (See note) 10 A (See note) 440 VAC, 300 VDC Failure rate (P level) (reference value*) 16 A 10 A 40 mA at 24 VDC * This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on sealed models. ■Characteristics Classification Item Number of poles Contact resistance *1 Operate (set) time Release (reset) time Insulation resistance *2 Between coil and contacts Between contacts Dielectric of the same strength polarity Between contacts of different polarity Impulse withstand voltage Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Standard type 1-pole High-capacity type 2-pole High-sensitivity type 1-pole 100 mΩ max. 15 ms max. 5 ms max. 1,000 MΩ min. 5,000 VAC, 50/60 Hz for 1min 1,000 VAC, 50/60 Hz for 1min − 2,500 VAC, 50/60 Hz for 1min − 10 kV (1.2 x 50 μs) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 Energized: 100 m/s2, De-energized: 100 m/s2 20,000,000 operations (at 18,000 operations/hr) G2RL-1(A)-E, G2RL-1A-E-ASI: 30,000 operations at 250 VAC, 16 A G2RL-2(A): G2RL-1(A): Durability Electrical *3 30,000 operations at 24 VDC, 16 A G2RL-1(A)-H: 50,000 operations at 250 VAC, 12 A 30,000 operations at 250 VAC, 8 A G2RL-1A-E-CV: 50,000 operations at 250 VAC, 10 A (resistive load) 30,000 operations at 30 VDC, 8 A 30,000 operations at 24 VDC, 12 A 50,000 operations at 250 VAC, 16 A at 105 C -40°C to 85°C (with no icing or condensation) Ambient operating temperature -40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV Ambient operating humidity 5% to 85% (with no icing or condensation) Weight Approx. 12 g Note. Values in the above table are the initial values at 23 C. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour. 2 G2RL PCB Power Relay ■Engineering Data AC resistive load 10 5 AC resistive load 10 5 50 5 DC resistive load 1 1 1 0.5 0.5 0.5 0.1 0.1 0.1 5 10 20 30 50 100 0 500 1,000 5 10 20 30 50 100 AC resistive load 10 5 DC resistive load Rated Carry Current (A) ●Ambient Temperature vs. Rated Carry Current 50 20 G2RL-1A-E, G2RL-1-E 16 15 G2RL-1A, G2RL-1 12 G2RL-1A-H, G2RL-1-H 1 5 10 20 30 50 100 ●Ambient Temperature vs. Maximum Coil Voltage 250 200 180 G 2 R L G2RL-1A-E-CV 150 10 130 8 110 100 Other type G2RL-2A, G2RL-2 0.5 500 1,000 Switching voltage (V) Switching voltage (V) Switching voltage (V) ●High-sensitivity type G2RL-1A-H, G2RL-1-H 0 500 1,000 Maximum coil voltage (%) 0 AC resistive load 10 DC resistive load DC resistive load Switching current (A) G2RL-2A, G2RL-2 50 Switching current (A) G2RL-1A-E, G2RL-1-E 50 Switching current (A) Switching current (A) ●Maximum Switching Capacity G2RL-1A, G2RL-1 5 50 0.1 0 5 10 20 30 50 100 500 1,000 Switching voltage (V) 0 10 20 30 40 50 60 70 80 85 90 100 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 85 90 100 105 110 Ambient temperature (°C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Must operate/must release voltage (percentage of rated voltage) (%) ●Ambient Temperature vs. Must Operate and Must Release Voltages 100 Sample: 90 G2RL-14-E 24 VDC Number of relays: 5 pcs 80 Must operate voltage Must release voltage max. X min. 70 60 50 40 max. X min. 30 20 10 0 20 40 60 80 100 120 Ambient temperature (°C) 3 G2RL PCB Power Relay ●Shock Malfunction G2RL-1 (A)-E Y NO contact G2RL-2 (A) Y 1,000 X' 1,000 NO contact Sample: G2RL-14 12 VDC Number of Relays: 5 pcs X' Test conditions: Shock is applied 1,000 in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 1,000 100 m/s2 Z 1,000 130 1,000 Z' 1,000 X NC contact 1,000 Y' Z 1,000 150 1,000 X NC contact Z' Y 1,000 Shock direction X X' Y Z Z' Unit: m/s2 Sample: G2RL-24 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 1,000 Y' Shock direction X X' Z Z' Unit: m/s2 Y' Y' ■Electrical Endurance Data (Reference Value) G 2 R L G2RL-1-E 8 A 250 VAC (cosφ=0.4) 8 A 30 VDC (L/R=7 ms) 200,000 operation min. (N.O.) 10,000 operation min. (N.O.) G2RL-1 5 A 250 VAC (cosφ=0.4) 5 A 30 VDC (L/R=7 ms) 150,000 operation min. (N.O.) 10,000 operation min. (N.O.) G2RL-2 8 A 250 VAC (cosφ=1) 8 A 30 VDC G2RL-1A-E Pilot duty (A300), 250 VAC 250,000 operation min. Pilot duty (A300), 125 VAC 150,000 operation min. 30,000 operation min. 10,000 operation min. Note. The results shown reflect values at ambient temperature 23 C. Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the electrical endurance under your test condition. ■Dimensions (Unit: mm) G2RL-1A, G2RL-1A4, G2RL-1A-H PCB Mounting Holes (Bottom View) 3.5 12.7 max. (12.5)* 29 max. (28.8)* Four, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 * Average value G2RL-1, G2RL-14, G2RL-1-H PCB Mounting Holes (Bottom View) 3.5 3.5 12.7 max. (12.5)* 29 max. (28.8)* Five, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 0.5 * Average value G2RL-1A-E (-HA), G2RL-1A4-E, G2RL-1A-E-CV, G2RL-1A-E-ASI PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 4 6 5 7.5 15.7 max. (15.5)* 8 (2.3) 0.5 3.5 0.5 0.8 0.5 * Average value 4 20 (No coil polarity) G2RL PCB Power Relay G2RL-1-E (-HA), G2RL-14-E PCB Mounting Holes (Bottom View) 5 5 12.7 max. (12.5)* 29 max. (28.8)* Eight, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 * Average value G2RL-2A (-HA), G2R-2A4 PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 4 8 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 * Average value G2RL-2 (-HA), G2R-24 PCB Mounting Holes (Bottom View) 5 5 12.7 max. (12.5)* 29 max. (28.8)* G 2 R L Terminal Arrangement/ Internal Connections (Bottom View) Eight, 1.3-dia. holes (2.5) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 * Average value ■Approved Standards • The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. UL Recognized: CSA Certified: Model (File No. 41643) (File No. LR31928) Contact form Coil ratings G2RL-1A G2RL-1 G2RL-1A-E (-HA) G2RL-1-E (-HA) SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPDT (1c) G2RL-1A-E-ASI SPST-NO (1a) 3 to 48 VDC G2RL-1A-E-CV G2RL-1A-H G2RL-1-H G2RL-2A (-HA) G2RL-2 (-HA) SPST-NO (1a) SPST-NO (1a) SPDT (1c) DPST-NO (2a) DPDT (2c) 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC 3 to 48 VDC Contact ratings 12 A, 250 VAC (General Use) 40°C 12 A, 24 VDC (Resistive) 40°C 16 A, 250 VAC (General Use) 40°C 16 A, 24 VDC (Resistive) 40°C 16 A, 250 VAC (Resistive) 85°C TV-3 40°C 16 A, 250 VAC (Resistive) 105°C 10 A, 250 VAC (General Use) 40°C 10 A, 24 VDC (Resistive) 40°C 8 A, 277 VAC (General Use) 40°C 8 A, 30 VDC (Resistive) 40°C Number of test operations 100,000 50,000 100,000 50,000 30,000 25,000 100,000 50,000 100,000 5 G2RL PCB Power Relay EN/IEC, VDE Certified Model G2RL-1A (Certificate No. 119650) Contact form Coil ratings SPST-NO (1a) 3 to 48 VDC G2RL-1 SPDT (1c) G2RL-1A-E (-HA) SPST-NO (1a) G2RL-1-E (-HA) SPDT (1c) G2RL-1A-E-ASI G2RL-1A-E-CV SPST-NO (1a) SPST-NO (1a) 3 to 48 VDC 3 to 48 VDC G2RL-1A-H G2RL-1-H SPST-NO (1a) SPDT (1c) 3 to 48 VDC G2RL-2A (-HA) DPST-NO (2a) G2RL-2 (-HA) DPDT (2c) 3 to 48 VDC 3 to 48 VDC G 2 R L Number of test operations Contact ratings 12 A, 250 VAC (cosφ=1) 85°C 12 A, 24 VDC (L/R=0 ms) 85°C AC15: 3 A at 240 VAC at room temperature DC13: 2.5 A at 24 VDC, 50ms at room temperature 16 A, 250 VAC (cosφ=1) 85°C 16 A, 24 VDC (L/R=0 ms) 85°C AC15: 3 A at 240 VAC (NO) at room temperature, 1.5 A at 240V AC (NC) at room temperature DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature 16 A, 250 VAC (cosφ=1) 85°C 16 A, 250 VAC (cosφ=1) 105°C 10 A, 250 VAC (cosφ=1) 85°C 10 A, 250 VAC (cosφ=1) 40°C 10 A, 24 VDC (L/R=0 ms) 85°C 8 A, 250 VAC (cosφ=1) 85°C 8 A, 30 VDC (L/R=0 ms) 85°C AC15: 1.5 A at 240VAC at room temperature DC13: 2 A at 30 VDC, 50ms at room temperature Creepage distance 8 mm min. Clearance distance 8 mm min. Insulation material group IIIa Type of insulation coil-contact circuit open contact circuit Reinforced Micro disconnection Rated Insulation voltage 250 V Pollution degree 3 (Flux protection / Sealed) 100,000 6,000 30,000 15,000 6,000 30,000 100,000 50,000 100,000 50,000 30,000 15,000 6,000 Rated voltage system 250 V / 400 V (Flux protection) Over voltage category III Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed) Glow wire according to IEC 60335-1 GWT 750 C min. (IEC 60695-2-11) / GWFI 850 C min. (IEC 60695-2-12) Tracking Index of relay base PTI 250 V min. (housing parts) ■Precautions • Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ● Mounting Position Compared to G2R Model • Although the G2RL model and the G2R model are both low profile Relays, their characteristics such as switching capacity are different. Be sure to check operation under the actual operating conditions before use. ● Cleaning • The G2RL model is flux-resistant with two sealing holes on the case. Thus, do not clean the Relay by boiling or soaking in water. Consult your Omron sales representative for sealed type Relay. ● Using Relays in an Atmosphere Containing Corrosive Gas • Do not use Relays in an atmosphere containing corrosive gas (sulfuric or organic gas).Otherwise, connection failure due to corrosion on the contact surface may lead to functional faults. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 6 Contact: www.omron.com/ecb Cat. No. J117-E1-10 0916(0207)(O)
G2RL1EDC5 价格&库存

很抱歉,暂时无法提供与“G2RL1EDC5”相匹配的价格&库存,您可以联系我们找货

免费人工找货