0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G32AA40VDDC524

G32AA40VDDC524

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Relay SSR 7mA 30V DC-IN 40A 264V AC-OUT

  • 数据手册
  • 价格&库存
G32AA40VDDC524 数据手册
Solid State Relays G3PA J26I-E-02 Extremely Thin Relays Integrated with Heat Sinks • Downsizing achieved through optimum design of heat sink. • Mounting possible via screws or via DIN track. • Close mounting possible for linking terminals. (Except for G3PA-260B-VD and G3PA-450B-VD-2.) • Applicable with 3-phase loads. • Replaceable power element cartridges. • Comply with VDE 0160 (finger protection), with a dielectric strength of 4,000 V between input and load. • Certified by UL, CSA, and VDE (reinforced insulation). * * Only UL and CSA certification applies to model numbers that end in -VD-X. Refer to Safety Precautions for All Solid State Relays. * * Not applicable to model numbers that end in -VD-X. Note: Manufacture of the following models will be discontinued at the end of March 2017: G3PA-210B-VD, G3PA-220B-VD, G32A-A10-VD, and G32A-A20VD. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend G3PA-@@@@-@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3PA:Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 4: 400 VAC 3. Rated Load Current 10: 10 A 20: 20 A 30: 30 A 40: 40 A 50: 50 A 60: 60 A 4. Terminal Type B: Screw terminals 5. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 6. Certification VD: Certified by UL, CSA, and VDE 7. Special Specifications Blank: Standard models 2: 480-V models X: Non-compliant of EN standard (CE mark) 1 G3PA Ordering Information ■ List of Models Model Isolation G3PA-210B-VD-X Phototriac coupler G3PA-210B-VD * Zero cross function Yes Indicator Yes G3PA-220B-VD-X Rated output load 10 A at 24 to 240 VAC Rated input voltage 5 to 24 VDC 20 A at 24 to 240 VAC G3PA-220B-VD * G3PA-240B-VD 40 A at 24 to 240 VAC G3PA-260B-VD 60 A at 24 to 240 VAC G3PA-210BL-VD No 10 A at 24 to 240 VAC G3PA-220BL-VD 20 A at 24 to 240 VAC G3PA-240BL-VD 40 A at 24 to 240 VAC G3PA-260BL-VD 60 A at 24 to 240 VAC G3PA-210B-VD Yes 10 A at 24 to 240 VAC G3PA-220B-VD 20 A at 24 to 240 VAC G3PA-240B-VD 40 A at 24 to 240 VAC G3PA-260B-VD 60 A at 24 to 240 VAC G3PA-420B-VD 20 A at 180 to 400 VAC G3PA-430B-VD 30 A at 180 to 400 VAC G3PA-420B-VD-2 20 A at 200 to 480 VAC G3PA-430B-VD-2 30 A at 200 to 480 VAC G3PA-450B-VD-2 50 A at 200 to 480 VAC 24 VAC 12 to 24 VDC Note: When ordering, specify the rated input voltage. * Manufacture will be discontinued at the end of March 2017. Replacement Parts Name Carry current Power Device Cartridge 10 A Load voltage range 19 to 264 VAC 20 A 40 A 60 A Model Applicable SSR G32A-A10-VD-X DC5-24 G3PA-210B-VD DC5-24 G3PA-210B-VD-X DC5-24 No G32A-A10-VD DC5-24 * G3PA-210B-VD DC5-24 Yes G32A-A10L-VD DC5-24 G3PA-210BL-VD DC5-24 G32A-A10-VD AC24 G3PA-210B-VD AC24 G32A-A20-VD-X DC5-24 G3PA-220B-VD DC5-24 G3PA-220B-VD-X DC5-24 No G32A-A20-VD DC5-24 * G3PA-220B-VD DC5-24 Yes G32A-A20L-VD DC5-24 G3PA-220BL-VD DC5-24 G32A-A20-VD AC24 G3PA-220B-VD AC24 G32A-A40-VD DC5-24 G3PA-240B-VD DC5-24 G32A-A40L-VD DC5-24 G3PA-240BL-VD DC5-24 G32A-A40-VD AC24 G3PA-240B-VD AC24 G32A-A60-VD DC5-24 G3PA-260B-VD DC5-24 G32A-A60L-VD DC5-24 G3PA-260BL-VD DC5-24 G32A-A60-VD AC24 G3PA-260B-VD AC24 150 to 440 VAC G32A-A420-VD DC12-24 G3PA-420B-VD DC12-24 G32A-A430-VD DC12-24 G3PA-430B-VD DC12-24 180 to 528 VAC G32A-A420-VD-2 DC12-24 G3PA-420B-VD-2 DC12-24 30 A G32A-A430-VD-2 DC12-24 G3PA-430B-VD-2 DC12-24 50 A G32A-A450-VD-2 DC12-24 G3PA-450B-VD-2 DC12-24 20 A 30 A 20 A VDE certification * Manufacture will be discontinued at the end of March 2017. ■ Other Units (Order Separately) Units that Enable 2-line Switching of 3-phase Power Name Short-circuit Unit Current flow 10 A Model G32A-D20 20 A 30 A Applicable SSR G3PA-210B-VD-X, G3PA-210BL-VD G3PA-220B-VD-X, G3PA-220BL-VD G3PA-420B-VD, G3PA-420B-VD-2 G32A-D40 40 A G3PA-430B-VD, G3PA-430B-VD-2 G3PA-240B-VD, G3PA-240BL-VD Note: Refer to List of Certified Models for a list of products that comply with safety standards. 2 G3PA Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input Model G3PA-210B-VD-X Rated voltage Operating Voltage range Input current impedance Voltage level Must operate voltage Must release voltage 5 to 24 VDC 4 to 30 VDC 7 mA max. 4 VDC max. 1 VDC min. 5 to 24 VDC 4 to 30 VDC 20 mA max. 4 VDC max. 1 VDC min. 24 VAC 19.2 to 26.4 VAC 1.4 kΩ±20% 19.2 VAC max. 4.8 VAC min. 12 to 24 VDC 9.6 to 30 VDC 7 mA max. 9.2 VDC max. 1 VDC min. G3PA-220B-VD-X G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Output Model Rated load voltage Load voltage range Load current Inrush current VDRM (reference value) G3PA-210B(L)-VD(-X) 24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.1 to 10 A at 40°C 150 A (60 Hz, 1 cycle) 600 V (VDRM) G3PA-220B(L)-VD(-X) 0.1 to 20 A at 40°C 220 A (60 Hz, 1 cycle) G3PA-240B(L)-VD 0.5 to 40 A at 40°C 440 A (60 Hz, 1 cycle) G3PA-260B(L)-VD 0.5 to 60 A at 40°C G3PA-420B-VD 180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0.5 to 20 A at 30°C G3PA-430B-VD 0.5 to 30 A at 30°C 440 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 1,000 V (VDRM) 440 A (60 Hz, 1 cycle) G3PA-420B-VD-2 200 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to 20 A at 30°C 220 A (60 Hz, 1 cycle) 1,200 V (VDRM) G3PA-430B-VD-2 0.5 to 30 A at 30°C 440 A (60 Hz, 1 cycle) G3PA-450B-VD-2 0.5 to 50 A at 30°C 440 A (60 Hz, 1 cycle) Refer to Engineering Data for further details. 3 G3PA ■ Characteristics Item G3PAG3PAG3PAG3PA210B(L)-VD(-X) 220B(L)-VD(-X) 240B(L)-VD 260B(L)-VD G3PA420B-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models) 1 1/2 of load power source cycle + 1 ms max. (AC Input) 1 ms max. (-BL models) Release time 1/2 of load power source cycle + 1 ms max. (DC Input) 1 1/2 of load power source cycle + 1 ms max. (AC Input) Output ON 1.6 V (RMS) max. voltage drop G3PA420B-VD-2 G3PA430B-VD G3PAG3PA430B-VD-2 450B-VD-2 1.8 V (RMS) max. Leakage current 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 10 mA max. (at 100 VAC) 20 mA max. 20 mA max. 20 mA max. 20 mA max. (at 480 20 mA max. (at 200 VAC) (at 400 VAC) (at 480 VAC) (at 400 VAC) VAC) I 2t 260 A2s 1,260 A2s Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 300 m/s2 (mounted to DIN track) 260 A2s 1,800 A2s 1,800 A2s 1,800 A2s Ambient Operating: –30°C to 80°C (with no icing or condensation) temperature Storage: –30°C to 100°C (with no icing or condensation) Certified standards UL508, CSA C22.2 (No.14, No.950), EN60950-1 File No. 5915ÜG EMC Emission: EN55011 Group 1 Class A Immunity: EN61000-6-2 Ambient humidity Operating: 45% to 85% Weight Approx. 260 g Approx. 340 g Approx. 460 g Approx. 900 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 6642ÜG UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 133127ÜG UL508, UL508, CSA C22.2 CSA C22.2 (No.14), EN60947-4-3 (No.14), File No. 133127ÜG EN60947-4-3 File No. 6642ÜG Approx. 290 g Approx. 290 g Approx. 410 g Approx. 410 g Approx. 900 g 4 G3PA Operation ■ Replacement Parts G32A-A Power Device Cartridge The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement. The damaged cartridge can be replaced with a new one without disconnecting the wires from the G3PA. Improve the heat radiation efficiency of the G3PA before replacing the cartridge. The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the short circuitry of the load, in which case the temperature indicator will not turn red. Be sure to turn OFF the power supply when replacing the Cartridge. Supplying power with the Cartridge removed may result in malfunction. To remove or replace the Power Device Cartridge for the G3PA-210B(L)-VD(-X), G3PA-220B(L)-VD(-X), or G3PA-420B-VD(-2), use the special tool provided with it for extraction. (No special tool is required for other models.) The G3PA can be broadly divided into two series: Previous models and models with model numbers that end with "-VD." The Cartridge shown at the right cannot be mounted to models in the G3PA-@@@B-(-US) Series. Appearance G32A-A10(L)-VD(-X) G32A-A420-VD(-2) G32A-A20(L)-VD(-X) G32A-A40(L)-VD G32A-A430-VD(-2) G32A-A60(L)-VD G32A-A450-VD-2 Replacing Power Device Cartridges When replacing Power Device Cartridges, use the specified model. Using a Power Device Cartridge other than the specified one will result in faulty operation and destruction of the elements. 5 G3PA ■ Replacement Procedure G32A-A10(L)-VD(-X)/G32A-A20(L)-VD(-X)/G32-A420-VD(-2) To remove or replace the Power Device Cartridge, use the special tool provided with it for extraction. (Do not switch on the power without the Power Device Cartridge. For details, see the attached the instruction sheet with the product.) Extraction Follow the procedures below to dismount the Power Device Cartridge from the G3PA. 1. Switch off the power. 2. Remove the terminal cover. 3. Hook the indented part of the cartridge with the tool and pull up on the cartridge to remove it. Remover Hook here with Remover. Apply silicone grease here. 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the G3PA. 3. Insert the cartridge into the opening of the G3PA so that the letters on the cartridge and those on the G3PA are in the same direction and side A and side B are even. Side A Side B Mounting Follow the procedures below to mount the Power Device Cartridge on the G3PA. 1. Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. 4. Attach the terminal cover. 5. Switch on the power and check the G3PA to be sure it works properly. G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit. No special tool is required to remove the Cartridge. Extraction Mounting Follow the procedures below to dismount the G32A-A Power Device Cartridge from the G3PA. 1. Apply silicone grease to the entire surface of the heat sink. 1. Switch off the power. 2. Remove the terminal cover. 3. Loosen the two centered screws on the sides to dismount the cartridge. The screws are connected to terminals 1 and 2. Apply silicone grease here. Loosen 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the G3PA. Loosen 4. Loosen the screws on both the corners. Loosen Loosen 5. Hold the indented part of both the corners to dismount the cartridge. 6 G3PA 3. Insert the cartridge into the opening of the G3PA so that side A and side B are even. Side A 4. Tighten the screws on both the corners with a tightening torque of 0.59 to 0.78 N·m. 5. Tighten the screws on both the sides with a tightening torque of 0.59 to 0.78 N·m. 6. Attach the terminal cover. 7. Switch on the power and check the G3PA to be sure it works properly. Side B ■ Linking Terminal Connection • Connecting with linking terminal for G3PA-210B(L)-VD(-X), -220B(L)-VD(-X), -240B(L)-VD and G3PA-420B-VD(-2), G3PA430B-VD(-2). SSR1 SSR2 SSR1 • Connecting with linking terminal for G32A. SSR G32A Unit SSR G32A Unit SSR2 * * The cover will not fit if the terminal protrudes. 1. When SSRs are close mounted, loosen the M3.5 Sems screw and flip the linking terminal down. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. 1. When SSR are close mounted, loosen the M3.5 Sems screw on the G32A and flip the linking terminal down. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. Ensure that the linking terminal does not protrude. Connect the terminal with power off. Linking terminal G3PA-420B-VD Refer to the instruction manual for the G32A-A Power Device Cartridge to replace the G3PA's triac part. Linking terminal When the temperature indicator has turned from pink to red, the G32-A-A Power Device Cartridge may have malfunctioned, in which case the cartridge must be replaced with a new one. Linking terminal Linking terminal Use the terminal cover to prevent accidents due to electric shock. 7 G3PA Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground G3PA-210B(L)-VD(-X), G3PA-220B(L)-VD(-X) G3PA-240B(L)-VD G3PA-260B(L)-VD G3PA-220B(L)-VD(-X) 80 Load current (A) G3PA-210B(L)-VD(-X) 15 Load current (A) Load current (A) 25 60 40 25 20 -30 -20 Ambient temperature (°C) Ambient temperature (°C) 0 20 40 60 80 100 Ambient temperature (°C) For close mounting of two or three SSRs, limit the load current to 90% or less. Ambient temperature (°C) G3PA-450B-VD-2 Load current (A) G3PA-430B-VD, G3PA-430B-VD-2 Load current (A) Load current (A) G3PA-420B-VD, G3PA-420B-VD-2 Ambient temperature (°C) Ambient temperature (°C) For close mounting of two or three SSRs, limit the load current to 80% or less. 8 G3PA Input Voltage vs. Input Current G3PA-4@0-VD, G3PA-4@-VD-2 Input impedance (kΩ) Input current (mA) Input impedance (kΩ) Input current (mA) G3PA-2@0B-VD(-X) Ta = 25°C 8 6 4 Input current 2 1 0.8 0.6 Input impedance 10 Input current 4 2 Input impedance 1 0.8 0.6 0.4 0.4 0.2 0.2 0.1 1 T = 25°C 8 6 0.1 2 4 6 8 10 20 1 40 2 4 6 8 10 20 40 Input voltage (V) Input voltage (V) Horizontal Mounting Panel Ground G3PA-220B(L)-VD(-X) 15 14 11 10 G3PA-210B(L)-VD(-X) 7 5.5 5 3.5 G3PA-260B(L)-VD Load current (A) 20 G3PA-240B(L)-VD Load current (A) Load current (A) G3PA-210B(L)-VD(-X), G3PA-220B(L)-VD(-X) 28 11 10 60 42 40 20 18 −30 −20 Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) 40 60 80 100 Load current (A) Load current (A) G3PA-420B-VD 20 G3PA-450B-VD-2 G3PA-420B-VD, G3PA-430B-VD G3PA-420B -VD-2, G3PA-430B-VD-2 G3PA-430B-VD 0 Ambient temperature (°C) Ambient temperature (°C) 9 G3PA Close Mounting (Up to Three) Panel Ground DIN track G3PA-210B(L)-VD(-X), G3PA-220B(L)-VD(-X) G3PA-240B(L)-VD G3PA-260B(L)-VD 30 45 27 20 G3PA-220B(L)-VD(-X) 18 15 13 9 G3PA-210B(L)-VD(-X) 7 5 4.5 64 36 Load current (A) Load current (A) Load current (A) 40 30 20 14 48 40 20 10 -30 -20 Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 20 40 60 80 100 G3PA-430B-VD, G3PA-430B-VD-2 30 40 Load current (A) Load current (A) 0 Ambient temperature (°C) 20 16 10 30 24 20 10 −30 10 30 80 Ambient temperature (°C) 100 −30 10 30 80 Ambient temperature (°C) Load current (A) G3PA-450B-VD-2 Ambient temperature (°C) 10 G3PA One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. Energized time (ms) G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2 Inrush current (A. Peak) G3PA-220B(L)-VD(-X), G3PA-420B-VD, G3PA-420B-VD-2 Inrush current (A. Peak) Inrush current (A. Peak) G3PA-210B(L)-VD(-X) Energized time (ms) Energized time (ms) 11 G3PA Dimensions Note: All units are in millimeters unless otherwise indicated. G3PA-210B(L)-VD(-X) With Terminal Cover Without Terminal Cover 4.6 dia. Two, M4 Linking terminal B1 Mounting Holes Terminal Arrangement/ Internal Connections Two, 4.5 dia. or M4 holes Input circuit Trigger circuit Two, M3.5 Linking terminal B2 4.6 x 5.6 elliptical hole 100 max. G3PA-220B(L)-VD(-X) Without Terminal Cover With Terminal Cover 4.6 dia. Linking terminal B1 Mounting Holes Two, M4 Terminal Arrangement/ Internal Connections Two, 4.5 dia. or M4 holes Input circuit Trigger circuit Two, M3.5 Linking terminal B2 4.6 x 5.6 elliptical hole 100 max. Linking terminal B1 With Terminal Cover 4.6 dia. Two, M5 Mounting Holes Two, 4.5 dia. or M4 holes Two, M3.5 Terminal Arrangement/ Internal Connections Input circuit Without Terminal Cover Trigger circuit G3PA-240B(L)-VD Linking terminal B2 4.6 x 5.6 elliptical hole 100 max. 12 G3PA With Terminal Cover Without Terminal Cover Terminal Arrangement/ Internal Connections Mounting Holes 4.6 dia. Two, M5 Two, 4.5 dia. or M4 holes Two, M3.5 G3PA-260B -VD 1 G3PA-450B -VD-2 1 + + Trigger circuit A1 Input circuit Trigger circuit A1 A2 4.6 x 5.6 elliptical hole 2 110 max. Input circuit G3PA-260B(L)-VD G3PA-450B-VD-2 A2 − 2 − 100 max. G3PA-420B-VD, G3PA-420B-VD-2 Without Terminal Cover With Terminal Cover Mounting Holes Two, 4.5 dia. or M4 4.6 dia. Terminal Arrangement/ Internal Connections Two, M4 7.6 Linking terminal −B2 90±0.3 80 Trigger circuit 38 100 max. Input circuit 90±0.2 Linking terminal 67 +B1 8.6 Two, M3.5 2.2 8.8 25±0.2 4.5 x 5.6 elliptic hole 100 max. 37 max. 4.5 13.2 91 90 G3PA-430B-VD, G3PA-430B-VD-2 Without Terminal Cover With Terminal Cover Mounting Holes Terminal Arrangement/ Internal Connections 4.6 dia. Two, M5 Two, 4.5 dia. or M4 Linking terminal +B1 100 38 max.90±0.2 80 90±0.3 Linking terminal −B2 Input circuit 67 Trigger circuit 7.6 13 18 13 4.6 x 5.6 elliptic hole 89 35±0.2 4.5 100 max. 47 max. 35±0.3 91 13 G3PA Safety Precautions ■ Precautions for Correct Use Load Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Load Connection Load power supply SSR Input When attaching a heat sink to the G3PA-(VD), in order to facilitate heat dissipation, apply silicone grease or equivalent heat-conductive grease on the heat sink. (Toshiba Silicone, Shinetsu Silicone, etc.) For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz. The G3PA-(VD) has a built-in varistor for overvoltage protection. Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N·m. At a low applied voltage, such as 24 VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. Noise Terminal Voltage according to EN55011 The G3PA-(VD) complies with EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram. Load Input G3PA-(VD) Output Loss time Recommended Capacitor: 1 µF, 250 VAC For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. Mounting Vertical • Screw or DIN track mounting is possible. • Vertical mounting should usually be used. Vertical mounting Vertical Panel DIN track G3PA Vertical The rated ambient temperature is 40°C. (30°C for 400 V.) G3PA 80 mm DIN track Close mounting • Close mounting cannot be used if the SSR is used at a 100% load current. Leave a gap of at least 10 mm on the left and right of each Unit. • Close mounting can be used under the following conditions: 1. Close mounting can be performed with no more than three SSRs (For four or more SSRs, leave a gap of at least 10 mm.) 2. Use a load current of 80% or less (90% or less for the G3PA-210B-VD, G3PA-220B-VD, or G3PA-240B-VD). 3. Leave a gap of at least 80 mm above and below the SSR. 4. Leave a gap of at least 60 mm from wiring ducts to the top of the SSR and at least 30 mm from wiring ducts to the bottom of the SSR. • With vertical mounting, reduce the load current by 30%. (Refer to the Load Current vs. Ambient Temperature graph.) Horizontal mounting Panel Note: Leave a distance of 60 mm min. between SSRs and ducts (especially above the SSR). 14 G3PA Close Mounting A heat exchanger, if used, should be located in front of the SSR Units to ensure the efficiency of the heat exchanger. SSR Mounting Pitch Please reduce the ambient temperature of SSRs. Panel Mounting (At a rated ambient temperature of 40°C). The rated load current of an SSR is measured at an ambient temperature of 25 or 40 °C. Duct or airflow obstruction SSR An SSR uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the SSRs and thus increase reliability. (Generally, each 10°C reduction in temperature will double the expected life.) 60 mm min. Between duct or airflow obstruction and SSR Mounting direction Vertical direction Load current (A) 30 mm min. 80 mm min. Space between SSRs 10 A Required number of fans 0.16 per SSR 20 A 0.31 30 A 0.47 40 A 0.62 60 A 0.93 Example: For 10 SSRs with load currents of 20 A, 0.31 x 10 = 3.1 Thus, 4 fans would be required. Close Mounting min. Size of fans: 92 mm2, Air volume: 0.7 m3/min, Ambient temperature of control panel: 30°C If there are other instruments that generate heat in the control panel other than SSRs, additional ventilation will be required. Relationship between SSRs and Ducts Countermeasure (1) Duct Height Countermeasure (2) 50 mm max. Vertical direction (A height of no more than half the SSR's height is recommended.) G3PA G3PA Mounting surface G3PA Mounting surface Mounting surface Duct or airflow obstruction Airflow Duct or airflow obstruction Do not surround the SSR with ducts, otherwise the heat radiation of the SSR will be adversely affected. Use short ducts. If the ducts cannot be shortened, place the SSR on a metal base so that it is not surrounded by the ducts. Ventilation Be aware of air flow Duct or air flow obstruction Ventilation outlet G3PA G3PA G3PA Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 15 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime J26I-E-02 12/16 Note: Specifications are subject to change. © 2016 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
G32AA40VDDC524 价格&库存

很抱歉,暂时无法提供与“G32AA40VDDC524”相匹配的价格&库存,您可以联系我们找货

免费人工找货