Solid-state Relay
G3FM
100-µA-max. Leakage Current, No
Bleeder Resistor Required
1 mA to 500 mA micro-load switching.
Switches to both AC and DC with no polarity.
Switches for a wide range of voltages; 19.2 to
264 VAC, 19.2 to 125 VDC.
Switches full- and half-wave rectifier AC loads.
Same sizes and terminal arrangement as OMRON
Power Relay MY Series.
Operating indicator provided.
Switches MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and
solenoids.
Ordering Information
Isolation
Zero cross
function
Photo-voltage
o o o age
l
coupler
No
o
Indicator
Yes
es
Applicable output load
Rated input voltage
0.5
at 19.2
0
5Aa
9 to
o 264
6 VAC
C
5 VDC
0.5 A at 19.2 to 125 VDC
12 VDC
Model
G3FM-2R5SLN
G3
5S
24 VDC
Accessories (Order Separately)
Connecting Socket
Refer to page 244 for details.
Item
PYF08A-E
PY08
PY08-02
Connecting
Front connecting
Back connecting
Mounting method/
Terminal type
Track mounted/
screw terminals
Solder terminals
Hold-down clip
PYC-A1
PYC-P
PY08QN(2)
PCB terminals
Wrapping terminals
Specifications
Ratings
Model
Input
Rated
voltage
Operating
voltage
Impedance
Output
Voltage levels
Must
operate
voltage
G3FM-2R5SLN
5 VDC
4 to 6 VDC
250 Ω±20%
4 VDC
max.
12 VDC
9.6 to
14.4 VDC
600 Ω±20%
9.6 VDC
max.
24 VDC
19.2 to
28.8 VDC
1.2 kΩ±20%
19.2 VDC
Must
release
voltage
1 VDC min.
Applicable load
Rated
load
voltage
Load
voltage
Load
curent
24 to
240 VAC
19.2 to
264 VAC
1 to
500 mA
24 to
110 VDC
19.2 to
125 VDC
Inrush
current
6A
(10 ms)
191
G3FM
G3FM
Characteristics
Operate time
5 ms max.
Release time
10 ms max.
Output ON voltage drop
3 V (RMS) max.
Leakage current
0.1 mA max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 50 g
Engineering Data
Load Current vs. Ambient
Temperature Characteristics
G3FM-2R5SLN
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
Load current (A)
Inrush current (A. Peak)
G3FM-2R5SLN
Ambient temperature (°C)
Energizing time (ms)
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Terminal Arrangement/
Internal Connections
(Bottom View)
1
28 max.
4
5
21.5 max.
9
36.5 max.
42.5 max.
13
8
Load
Input
–
–
192
Load
Load power supply
12
14
+
Input voltage
+
G3FM
G3FM
Precautions
Refer to pages 11 to 19 for general precautions.
The SSR case serves to dissipate heat. Install the relays so that
they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K072-E1-1A
193
很抱歉,暂时无法提供与“G3FM2R5SLNDC24”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+1012.244801+131.22362