Solid-state Relay
G3H/G3HD
Plug-in Type Power Relays (Same as the
LY Series)
Available in 2 types, DC input-AC input and DC
input-DC output.
Same sizes and terminal arrangement as LY
Series.
Operating indicator provided
Ordering Information
Isolation
Zero cross
function
Photocoupler
Yes
Phototriac
o o ac coupler
cou e
No
Indicator
Yes
Rated output load
(Applicable output load)
at 100
3Aa
00 to
o 240
0 VAC
C
t 264 VAC)
(3 A att 75 to
(see note 2)
Rated input voltage
Model
5 to 24 VDC
G3H-203SN
5 VDC
G3H-203SLN
12 VDC
24 VDC
Photocoupler
No
Photocoupler
Yes
Phototriac
o o ac coupler
cou e
No
No
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC)
(see note 3)
5 to 24 VDC
G3HD-X03SN
3Aa
at 100
00 to
o 240
0 VAC
C
(3 A att 75 to
t 264 VAC)
(see note 2)
4 to 24 VDC
G3H-203S
5 VDC
G3H-203SL
12 VDC
24 VDC
Photocoupler
Note:
No
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC)
(see note 3)
4 to 24 VDC
G3HD-X03S
1. Models to be used with a full-wave rectifier can be ordered by adding “-V” after the model number. This rectifier is available only on
models without the zero cross function (e.g., G3H-203SL-V).
2. Product is labelled “250 VAC”.
3. Product is labelled “50 VAC”.
Accessories (Order Separately)
Connecting Socket
Refer to page 244 for details.
Item
PTF08A-E
PT08
Connecting
Front connecting
Back connecting
Mounting method/
Terminal type
Track mounted
screw terminals
Solder terminals
Hold-down clip
PYC-A1
PYC-P
PT08-0
PCB terminals
PT08QN
Wire-wrapping
terminals
197
G3H/G3HD
G3H/G3HD
Specifications
Ratings
Input
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate
voltage
Must release
voltage
G3H-203SN
5 to 24 VDC
4 to 28 VDC
1.5 kΩ +20%/–10%*
4 VDC max.
1 VDC min.
G3H-203SLN
5 VDC
4 to 6 VDC
390 Ω±20%
4 VDC max.
1 VDC min.
12 VDC
9.6 to 14.4 VDC
900 Ω±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 kΩ±20%
19.2 VDC max.
G3HD-X03SN
5 to 24 VDC
4 to 28 VDC
1.5 kΩ +20%/–10%*
4 VDC max.
1 VDC min.
G3H-203S
4 to 24 VDC
3 to 28 VDC
1.5 kΩ +20%/–10%*
3 VDC max.
1 VDC min.
G3H-203SL
5 VDC
4 to 6 VDC
390 Ω±20%
4 VDC max.
1 VDC min.
12 VDC
9.6 to 14.4 VDC
900 Ω±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 kΩ±20%
19.2 VDC max.
4 to 24 VDC
3 to 28 VDC
1.5 kΩ +20%/–10%*
3 VDC max.
G3HD-X03S
1 VDC min.
*Input impedance is the maximum value at the operating voltage.
Output
Model
Applicable load
Rated voltage
G3H-203SN
G3H-203S
Voltage range
Load current
Inrush current
100 to 240 VAC
75 to 264 VAC
0.1 to 3 A
45 A 60 Hz, 1 cycle
4 to 48 VDC
3 to 52.8 VDC
0.1 to 3 A
18 A (10 ms)
G3H-203SLN
G3H-203SL
G3HD-X03SN
G3HD-X03S
Characteristics
Model
G3H-203SN/203S
G3H-203SLN/203SL
1/2 cycle of load power source +
1 ms max.
Release time
1/2 cycle of load power source + 1 ms max.
2 ms max.
Output ON voltage drop
1.6 V (RMS) max.
1.5 V max.
Leakage current
5 mA max. (at 100 VAC);
10 mA max. (at 200 VAC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing)
Storage: –30°C to 100°C (with no icing)
Ambient humidity
45% to 85%
Weight
Approx. 50 g
198
1 ms max.
G3HD-X03SN/X03S
Operate time
2.5 mA max. (at 100 VAC);
5 mA max. (at 200 VAC)
0.5 ms max.
5 mA max. (at 50 VDC)
G3H/G3HD
G3H/G3HD
Engineering Data
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
G3H-203SN/203S/203SLN/203SL
G3HD-X03SN/X03S
G3H-203SN/203S/203SLN/G3H-203SL
G3HD-X03SN/X03S
Inrush current (A)
Load current (A)
Inrush current (A, Peak)
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
Energizing time (ms)
Ambient temperature (°C)
Energizing time (ms)
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Terminal Arrangement/
Internal Connections
(Bottom View)
2
1
4(+)
3
28 max.
5
21.5 max.
Load
Load
(+)
6(–)
(–)
36.5 max.
42.5 max.
7
Input
–
8
+
–
Input voltage
Note:
+
1. The plus and minus symbols
shown in the parentheses
are for DC loads.
2. The coil has no polarity.
Precautions
Refer to pages 11 to 19 for general precautions.
The SSR case serves to dissipate heat. Install the relays so that
they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Protective Component
Since the SSR does not incorporate an overvoltage absorption
component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load.
Connection
With the SSR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K057-E1-4A
199
很抱歉,暂时无法提供与“G3HDX03SNVDDC524”相匹配的价格&库存,您可以联系我们找货