G3VM-101AR/DR
MOS FET Relays
DIP
Compact, General-purpose,
Analog-switching MOS FET Relays,
with 1-A Switching.
• Continuous load current of 1 A.
• Switches minute analog signals.
G3VM-101AR/DR
• Dielectric strength of 2,500 Vrms between I/O.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
4
• Communication equipment
3
Mold pin mark ∗
OMRON logo
• Test & Measurement equipment
Model name
• Security equipment
Pin 1 mark
932
LOT No.
• Factory Automation equipment
1
• Power circuit
2
Note: The actual product is marked differently from the image shown here.
∗ The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■ List of Models
Package type
Contact form
DIP4
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
PCB terminals
Minimum package quantity
Model
Number per stick Number per tape and reel
G3VM-101AR
100 V
Surface-mounting terminals
G3VM-101DR
G3VM-101DR (TR)
100
---
---
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between I/O (See note 1.)
Operating temperature
Storage temperature
Soldering temperature
Output
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
Iop
TJ
VI-O
Ta
Tstg
---
Rating
30
1
−0.3
5
125
100
1
−10
3
125
2500
−40 to +85
−55 to +125
260
(Ta = 25°C)
Unit
mA
A
mA/°C
V
°C
V
A
mA/°C
A
°C
Vrms
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note:
1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.18
1.33
1.48
Reverse current
IR
----10
Capacity between terminals
CT
--70
--Trigger LED forward current
IFT
--0.5
3
Maximum resistance with output ON
RON
--250
700
Current leakage when the relay is open
ILEAK
----1.0
Capacity between terminals
COFF
--200
--Capacity between I/O terminals
CI-O
--0.8
--Insulation resistance between I/O terminals
RI-O
1000
----Turn-ON time
tON
--0.8
5
Turn-OFF time
tOFF
--0.3
1
Output
1
Unit
V
µA
pF
mA
mΩ
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note:
VR = 5 V
V = 0, f = 1 MHz
Io = 1 A
IF = 5 mA, Io = 1 A, t < 1 s
VOFF = 100 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
IF = 5 mA, RL = 200Ω,
VDD = 20 V (See note 2.)
2. Turn-ON and Turn-OFF Times
IF
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
G3VM-101AR/DR
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Minimum
Typical
Maximum
Unit
VDD
---
---
80
V
IF
5
10
25
mA
IO
---
---
1
A
Ta
−20
---
65
°C
DIP
Symbol
Load voltage
(AC peak/DC)
Operating LED forward current
Continuous load current
(AC peak/DC)
Operating temperature
■Engineering Data
Continuous load current vs.
Ambient temperature
LED forward current vs.
LED forward voltage
IO - Ta
40
30
20
IF - VF
1.5
LED forward current IF (mA)
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
50
G3VM-101AR/DR
LED forward current vs.
Ambient temperature
1
100
Ta = 25°C
10
1
0.5
0.1
10
-20
0
20
40
60
80
0.01
0
-40
100
-20
0
Ambient temperature Ta (°C)
Continuous load current vs.
On-state voltage
40
60
100
80
On-state resistance vs.
Ambient temperature
On-state resistance RON (mΩ)
Ta = 25C
IF = 5mA
0.5
-0.5
IO = 1A
IF = 5mA, t < 1s
400
300
200
0.1
0.2
0.3
-40
-20
0
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time tON, tOFF (ms)
80
IO = 1A
t < 1s
1
0
-40
100
-20
0
20
Ta = 25°C
10
1
t off
0.1
t on
0.01
100
RL = 200Ω
IF = 5mA
10
1
t on
t off
0.1
LED forward current IF (mA)
0
20
40
80
100
ILEAK - Ta
VDD = 20V
-20
60
Current leakage vs.
Ambient temperature
100
0.01
-40
40
Ambient temperature Ta (°C)
tON, tOFF - Ta
VDD = 20V
10
60
Turn ON, Turn OFF time vs.
Ambient temperature
RL = 200Ω
1
40
2
2
Ambient temperature Ta (°C)
tON, tOFF - IF
100
20
Current leakage ILEAK (nA)
0
1.5
IFT - Ta
500
0
-0.1
1
LED forward voltage VF (V)
Trigger LED forward current vs.
Ambient temperature
100
-0.2
0.5
RON - Ta
1.5
-1.5
-0.3
0
Ambient temperature Ta (°C)
IO - VON
Continuous load current IO (A)
20
Trigger LED forward current IFT (mA)
0
-40
60
80
100
VOFF = 100V
10
1
0.1
100
Ambient temperature Ta (°C)
0.01
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP4
■ Appearance
DIP (Dual Inline Package)
DIP4
Mold pin mark∗
OMRON logo
Model name
Pin 1 mark
932
LOT No.
Note: The actual product is marked differently from the image shown here.
∗ The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit: mm)
PCB Terminals
Surface-mounting Terminals
Weight: 0.25 g
Weight: 0.25 g
PCB Dimensions (Bottom View)
Four, 0.8-dia. holes
2.54
(0.61)
2.54
4.58±0.25
4.58±0.25
6.4±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
7.62±0.25
0.8±0.25
(Recommended Value, Top View)
3.65 +0.15
−0.25
0.25 +0.1
−0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
3.65 +0.15
−0.25
2.54
4.0 +0.25
−0.2
1.0 min.
7.85 to 8.80
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
1.0 min.
8.3 to 8.8
10.0 max.
1.3
1.5
image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K141-E1-02
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-101AR”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+68.35321
- 10+53.46778
- 50+50.55914
- 100+45.51178
- 200+42.85978