MOS FET Relays
Low 100-mΩ ON Resistance. Higher power, 1.4-A switching with a 100-V load voltage, SOP package.
• Continuous load current of 1.4 A (connection C = 2.8 A). • Dielectric strength of 1,500 Vrms between I/O. RoHS compliant
! Refer to “Common Precautions”.
G3VM-101HR
■ Application Examples
• Broadband systems • Measurement devices • Data loggers • Industrial equipment
Note:
The actual product is marked differently from the image shown here.
■ List of Models
Contact form SPST-NO Terminals Surface-mounting terminals Load voltage (peak value) (See note.) 100 V Model G3VM-101HR G3VM-101HR(TR) Number per stick 75 --Number per tape --2,500
Note:
The AC peak and DC value is given for the load voltage.
■ Dimensions
Note: All units are in millimeters unless otherwise indicated. G3VM-101HR
4.4±0.25
6.3±0.25
2.1 max. 0.15
Note: The actual product is marked differently from the image shown here.
2.54±0.25
0.1±0.1 0.4±0.1
0.6±0.3 7.0±0.4
Weight: 0.13 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-101HR
6 5 4
1
2
3
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-101HR
6 to 6.3 1.2
0.8 2.54 2.54
54
G3VM-101HR ■ Absolute Maximum Ratings (Ta = 25°C)
Item Input LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Output Load voltage (AC peak/DC) Continuous load current Connection A Connection B Connection C ON current reduction rate Connection A Connection B Connection C Pulse on current Connection temperature Dielectric strength between input and output (See note 1.) Operating temperature Storage temperature Soldering temperature (10 s) Iop Tj VI-O Ta Tstg --∆ IIO/°C Symbol IF ∆ IF/°C VR Tj VOFF IO Rating 30 −0.3 5 125 100 1.4 1.4 2.8 −18.7 −18.7 −37.3 4 125 1,500 −40 to +85 A °C Vrms °C °C AC for 1 min With no icing or condensation With no icing or condensation 10 s
1 1
G3VM-101HR
Unit mA mA/°C V °C V A
Measurement Conditions Ta ≥ 25°C
Note:
1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A: AC peak/DC Connection B and C: DC Ta ≥ 50°C
6 5 4 Load DC 1 6 5 4 Load AC or DC
Connection A
2 3
mA/°C
t = 100 ms
Connection B
2 3
−55 to +125 °C 260
6 5 4
Load DC
Connection C
2 3
■ Electrical Characteristics (Ta = 25°C)
Item Input LED forward voltage Reverse current Capacity between terminals Trigger LED forward current Output Maximum resistance with output ON Connection A Connection B Connection C Current leakage when the relay is open Capacity between I/O terminals Insulation resistance Turn-ON time Turn-OFF time ILEAK CI-O RI-O tON tOFF Symbol VF IR CT IFT RON Minimum 1.18 ----------------1,000 ----Typical 1.33 --70 0.4 0.1 0.05 0.025 --0.8 --1.0 0.15 Maximum 1.48 10 --3 0.2 0.1 --10 ----5.0 1.0 V µA pF mA Ω Ω Ω nA pF MΩ ms ms Unit Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz IO = 100 mA IF = 5 mA, IO = 1.4 A, t < 1S IF = 5 mA, IO = 1.4 A, t < 1S IF = 5 mA, IO = 2.8 A, t < 1S VOFF = 100 V f = 1 MHz, Vs = 0 V VI-O = 500 VDC, RoH ≤ 60% IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.)
VOUT IF
Note:
2. Turn-ON and Turn-OFF Times
IF 1 2 6 4 RL VDD VOUT
10% t ON
90% t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Operating temperature Symbol VDD IF IO Ta --5 --−20 Minimum --7.5 ----Typical Maximum 100 20 1.1 65 V mA A °C Unit
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-101HR
Load current (A) 3 Connection C
■ Safety Precautions
Refer to “Common Precautions” for all G3VM models.
2.5
2
1.5 Connection A, Connection B
1
0.5
0 −20
0
20
40
60
80
100
Ambient temperature (°C)
55