G3VM-21BR/ER
MOS FET Relays
DIP
Higher power, 4-A switching with a 20-V
load voltage, DIP package.
Low 20 mΩ ON Resistance.
• Continuous load current of 4 A. (Connection C: 8 A)
• Switches minute analog signals.
G3VM-21BR/ER
• Dielectric strength of 2,500 Vrms between I/O.
Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
• Communication equipment
5
4
• Test & Measurement equipment
OMRON logo
Model name
• Security equipment
932
Pin 1 mark
Lot No.
• Factory Automation equipment
1
• Power circuit
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type
Contact form
DIP6
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
PCB terminals
Minimum package quantity
Model
Number per stick Number per tape and reel
G3VM-21BR
20 V
Surface-mounting terminals
G3VM-21ER
G3VM-21ER (TR)
50
---
---
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
Connection B
reduction rate
Connection C
Pulse ON current
Connection temperature
Dielectric strength between I/O (See note 1.)
Operating temperature
Storage temperature
Output
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
Iop
TJ
VI-O
Ta
Tstg
---
Rating
30
1
−0.3
5
125
20
4
4
8
−40
−40
−80
12
125
2500
−40 to +85
−55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
A
mA/°C
A
°C
Vrms
°C
°C
°C
Measurement conditions
Note:
100 µs pulses, 100 pps
Ta ≥ 25°C
1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
Connection
A
Connection
B
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
Connection
C
10 s
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
■ Electrical Characteristics (Ta = 25°C)
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.18
1.33
1.48
Reverse current
IR
----10
Capacity between terminals
CT
--70
--Trigger LED forward current
IFT
--0.5
3
Connection A
--20
50
Maximum
resistance with Connection B
RON
--10
--output ON
Connection C
--5
--Current leakage when the relay is open
ILEAK
----1.0
Capacity between terminals
COFF
--1000
--Capacity between I/O terminals
CI-O
--0.8
--Insulation resistance between I/O terminals
RI-O
1000
----Turn-ON time
tON
--2.5
5
Turn-OFF time
tOFF
--0.1
1
Output
1
Unit
V
µA
pF
mA
mΩ
mΩ
mΩ
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
Note:
V = 0, f = 1 MHz
IO = 1 A
IF = 5 mA, IO = 2 A, t < 1s
IF = 5 mA, IO = 2 A, t < 1s
IF = 5 mA, IO = 4 A, t < 1s
VOFF = 20 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
2. Turn-ON and Turn-OFF Times
IF
1
6
2
4
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
Load
AC
or
DC
Load
DC
Load
DC
G3VM-21BR/ER
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Load voltage
(AC peak/DC)
Typical
Maximum
Unit
---
---
16
V
IF
5
10
25
mA
Continuous load current
(AC peak/DC)
IO
---
---
4
A
Operating temperature
Ta
−20
---
65
°C
DIP
VDD
Operating LED forward current
■ Engineering Data
Continuous load current vs.
Ambient temperature
LED forward current vs.
LED forward voltage
IO - Ta
40
30
20
IF - VF
10
LED forward current IF (mA)
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
50
Connection C
Connection A,
Connection B
5
G3VM-21BR/ER
LED forward current vs.
Ambient temperature
100
Ta = 25°C
10
1
0.1
10
0
-20
0
20
40
60
80
0.01
-40
100
0
-20
Ambient temperature Ta (°C)
Continuous load current vs.
On-state voltage
On-state resistance RON (mΩ)
Continuous load current IO (A)
60
80
100
0
0.5
1
IF = 5mA
Connection A
2
1
0
-1
-2
-3
2
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
50
IO = 2A
IF = 5mA, t < 1s
40
1.5
LED forward voltage VF (V)
RON - Ta
IO - VON
Ta = 25°C
3
40
Ambient temperature Ta (°C)
On-state resistance vs.
Ambient temperature
5
4
20
Trigger LED forward current IFT (mA)
0
-40
Connection A
30
20
10
2
IO = 1A
t < 1s
Connection A
1
-4
-5
0
-0.05
0
0.05
0
-40
0.1
-20
0
60
80
100
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - IF
VDD = 20V
RL = 200Ω
Ta = 25°C
10
1
t on
t off
0.1
0.01
-20
0
10
100
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs.
Ambient temperature
ILEAK - Ta
100
VDD = 20V
RL = 200Ω
IF = 5mA
10
t on
1
t off
0.1
100
VOFF = 20V
10
1
0.1
0.01
1
-40
tON, tOFF - Ta
100
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time tON, tOFF (ms)
40
Ambient temperature Ta (°C)
On-state voltage VON (V)
Turn ON, Turn OFF time vs.
LED forward current
20
Current leakage ILEAK (nA)
-0.1
0.01
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP6
■ Appearance
DIP (Dual Inline Package)
DIP6
OMRON logo
Model name
932
Pin 1 mark
Lot No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
PCB Terminals
Surface-mounting Terminals
Weight: 0.4 g
Weight: 0.4 g
PCB Dimensions (Bottom View)
Six, 0.8-dia. holes
2.54
(0.61)
2.54
7.12±0.25
7.12±0.25
6.4±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
0.8±0.25
7.62±0.25
(Recommended Value, Top View)
3.65+0.15
−0.25
0.25+0.1
−0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
3.65+0.15
−0.25
4.0+0.25
−0.2
2.54
2.54
1.0 min.
7.85 to 8.80
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K136-E1-02
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-21ER”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+66.78811
- 10+49.47915